SPECIFICATIONS:
MECHANICAL:
XT CASE DIMENSIONS:
2.75”w x 4.50”h x 1.50”d
PROGRAMMER CASE DIMENSIONS:
2.75”w x 4.50”h x 2.50”d
ELECTRICAL:
VOLTAGE:
12-24 Volts AC/DC (selected by P5 jumper)
CURRENT:
@12-24 Volts AC/DC- 20ma typical-150ma max with all
relays energized
OUTPUTS:
Main relay: 8 Amp, Form-C @ 24volts-10 AMP surge
Relays 2, 3, & 4 are Form C relays-1 AMP MAXIMUM
232xt Wiring Diagrams and Specifications
P1
P4
P3
P2
RELAY
V+ VNO
SW1
NC C
P1-REX INPUT/DOOR POSITION INPUT
P2-ALARM SHUNT RELAY
P3-FORCED DOOR RELAY
P4-DOOR AJAR RELAY
P5-VOLTAGE SELECTOR
SW1-PROGRAMMING SWITCH
P5*
*P5 is the Voltage Selector. With the jumper in position one, 12-15vdc only operation is
selected. With the jumper in position two 15-24vdc/12-24vac operation is selected.
Packing Checklist:
Xtreme™ Keypad
232 XT Programming Controller
Four Conductor Wire Harness (2)
Three Conductor Wire Harness (4)
Slotted Screws (4)
Plastic Anchors (4)
5/64 Allen Head Wrench (1)
Machine Screws (2)
Tech Supp. With Warranty card
ACCESS CONTROL Features and Programming Guide
TM
INTERNATIONAL
ELECTRONICS, INC
INTERNATIONAL ELECTRONICS, INC.
427TURNPIKE STREET, CANTON,MA02021 U.S.A.
800-343-9502, 617-821-5566 (FAX)617-821-4443
P5*
Position
1
12-15VDC
12-24VAC
6063170 REV 1.01
Voltage Selection Settings
15-24VDC
ENVIRONMENTAL:
TEMPERATURE:
-20°F TO 130°F (-28°C TO 54°C)
123
4 5 6
7 8 9
*0#
( White / Yellow )
( White / Black )
( Black )
Wire Xtreme Pad
color to color to the
wires on Programmer
(Red to Red, ect.)
Visit our website for Access Control & Glassbreak information,
New Products, Specifications, Applications, Seminars, and Partners
@ www.ieib.com
Position
Voltmeter
Electrical
Tape
Electrical
Tape
Insulator
BLACK
REDBLACK/WHITE
BLACK\YELLOW
ì
ê
Drain Wire
to V- on
Hub
è
WIRING THE XTREME™
The Xtreme™ keypad is a device which you choose to place either inside or outside the door.
IEI manufactures several other devices to choose from; keypads, magnetic card readers, proximity
card readers, and touch chip readers.
Choosing the correct device for the application is important. IEI manufactures light traffic and
heavy traffic devices. If you are not sure which device to utilize, please call us at 1-800-343-9502.
TESTING THE Xtreme™ KEYPAD FOR GROUND POTENTIAL DIFFERENCES
Wiring the Xtreme™ keypad to the programming control unit requires a four conductor,stranded
and shieldedcable to be wired between two units. Maximum lengths are as follows:
At the programming control unit, connect the four conductor cable to the four pin connector on the
controller relay board, as shown in the diagram above. The drain wire at the programming controller
must be attached to ground, also the foil shield should be cut back with the insulator and taped with
electrical tape. Ground is the V- terminal on TS1 if the power supply is grounded. At the
Xtreme™ keypad, the drain wire and foil shield is cut back with the insulator and taped with electri-
cal tape. The four conductor harness connects into the four wire harness on the Xtreme™ keypad.
Both wire harnesses are connected to each other color to color.
22 AWG stranded : 250 feet
20 AWG stranded : 500 feet
18 AWG stranded : 1000 feet
48
If the Xtreme™ keypad is mounted to the metal door frame of the building, a ground potential
test should be run. This test is important because a potential difference between the power supply
ground and the ground on the metal frame of a building can render the system inoperable. The
Xtreme™ keypad should first be installed and the power supply grounded and turned off. Now set
up a meter to read DC voltage. At programming controller separate the black wire of the four con-
ductor cable from the wire running to the Xtreme™ keypad and attach the meter in series with the
two wires per diagram above. If the meter shows more than one volt then the front end must either
be insulated from the frame or the ground wire of the reader must be removed. Setup meter to read
AC voltage and repeat test. On the Xtreme™ keypad you will find the grounding wire screwed to
the case at one end and plugged into the circuit board on the other end. If you have any questions
about this procedure please call IEI Technical Support,1-800-343-9502.
* - Wire harness is shown in reverse for ease of meter discription
( Black on the bottom, Red ,ect..)
Propped Door Relay
This output is utilized to inform personnel that the door is being held, or propped open, after a
valid entry. To accomplish this, the Xtreme™ programming controller comes equipped with a relay
and an internal timer circuit that is designated for this purpose. The form C relays are rated to han-
dle one (1) amp of current at either 12 volts or 24 volts, type AC or DC, and can turn on or off one
leg of power to a warning device. Warning device not included with IEI equipment.
1. Connect the three conductor harness with the green,
blue, and gray wire to the propped door relay jack as
shown in diagram A.
2. Connect green wire to V+ on sounder.
3. Connect blue wire to V+ from power supply.
4. Connect V- from power supply to V- on sounder.
5. Gray wire is not used.
DIAGRAM A
Xtreme™ CONTROL RELAY BOARD
V-
V+
V+GREEN (NO)BLUE (C)
GRAY (NC) NOT USED
Programming the Propped Door Relay
To program how long the door can be propped open
before the alarm is tripped, Program as follows:
**No programming is done at the Xtreme™ keypad.**
1. Enter programming mode. Press 99 # (master code) *
2. Verify that the programmer is in programming mode.
(Yellow light should be flashing slowly.)
To
Power Supply
To incorporate this feature into your system, simply locate one of the five connectors, each one
with three (3) wires, green, blue, and gray, located in the box with the Xtreme™ programming con-
troller. With the controller powered down, unlatch the keypad from the plastic housing and slide the
printed circuit board out of housing, exposing the connectors as shown in Diagram A.
3. Press 44 # (time) # 0 # **, time represents how
long the door may be propped before the relay
energizes. Time must be 10 to 900 seconds
Propped door time must be programmed in inter-
vals of 10 seconds, ie. 10, 30, 60,... up to 900
seconds.
4. Press * to exit program mode, yellow light
should not be flashing.
NOTE: This feature requires that you utilize the
Normally closed door contact (input) per dia-
gram B.
Normally
closed
door contactwhite wire
with orange
stripe
white wire
DIAGRAM B.
Propped
Door
Relay
Wiring the Propped Door Relay
Forced Door Relay
Forced
Door
Relay
This output is utilized to inform personnel that the door had been opened without authorization.
To accomplish this, the Xtreme™ programming controller comes equipped with a relay and an inter-
nal timer circuit that is designated for this purpose. The form C relays are rated to handle one (1)
amp of current at either 12 volts or 24 volts, type AC or DC, and can turn on or off one leg of power
to a warning device. Warning device not included with IEI equipment.
To incorporate this feature into your system, simply locate one of the five connectors, each one
with three (3) wires, green, blue, and gray, located in the box with the Xtreme™ programming con-
troller. With the controller powered down, unlatch the keypad from the plastic housing and slide the
printed circuit board out of housing, exposing the connectors as shown in Diagram A.
Wiring the Forced Door Relay
1. Connect the three conductor harness with the green, blue,
and gray wire to the forced door relay jack as shown in dia-
gram A.
2. Connect green wire to V+ on siren.
3. Connect blue wire to V+ from power supply.
4. Connect V- from power supply to V- on sounder.
5. Gray wire is not used.
Xtreme™ CONTROL RELAY BOARD
DIAGRAM A.
To
Power Supply
V+
V+
V-
GRAY (NC) NOT USED
GREEN (NO)
BLUE (C)
Programming the Forced Door Relay
To program the time that the forced door output
will stay energized, program as follows:
**No programming is done at the Xtreme™ keypad.**
1. Enter programming mode. Press 99 # (master
code) *
2. Verify programmer is in programming mode.
Yellow light should be flashing slowly.
3. Press 45 # (time) # 0 # * *, time represents how
long the relay stays energized, 10 to 900 sec-
onds, in Ten second intervals, or you may
press 00 for a latched output,
requiring a valid code to reset output. Forced
door time must be programmed in intervals of
10 seconds, ie. 10, 30, 60,... up to 900 seconds.
4. Press * to exit program mode, yellow light
should not be flashing.
white wire
with orange
stripe
white wire
NOTE:This feature requires that you utilize the
normally closed door contact (input) per dia-
gram B.
DIAGRAM B.
Normally
closed
door contact
Alarm Shunt Relay
Alarm
Shunt
Relay
green
blue
gray (not used)
Pre existing
alarm panel
door contact
DIAGRAM A
DIAGRAM B.
Xtreme™ CONTROL RELAY BOARD
The Alarm shunt relay may be necessary to use when a
security system or other type of system has already been in
existence. The Alarm shunt relay keeps the alarm from acti-
vating when the door is opened, by keeping either a closed or
opened state on the existing alarm panels zone. The Alarm
shunt relay operates when the set of normally closed door
contacts has been opened after a valid code entry. No pro-
gramming required. The time of operation follows the main
relay time.
To incorporate this feature into your system, simply locate
one of the three connectors, each one with three (3) wires,
green, blue, and gray, located in the box with the Xtreme™
programming contoller. With the controller powered down,
unlatch the keypad from the plastic housing and slide the
printed circuit board out of housing, exposing the connectors
as shown in diagram A.
Wiring the Alarm Shunt Relay
1. Connect the three conductor harness with the green, blue,
and gray wire to the alarm shunt relay jack as shown in dia-
gram A.
2. Connect green wire to “Common” side of door contact.
3. Connect blue wire to “Normally Open” side of door contact.
4. Make a parallel connection to the green and blue wires,(as
shown in diagram A.), and run the leads to the alarm panel.
NOTE: This feature requires that you utilize the normally
closed door contact (input) per diagram B.
door contact
white wire with
orange stripe
white wire
Auto Re-Lock
Auto Re-Lock solves the problem of people
“tailgating” in behind those using valid access
protocol, allowing the programmer the opportuni-
ty to set a long door open time. This feature
over-rides the main relay timer, resetting the
door open time as soon as the controller sees
the door open. In many situations, you will find
yourself programming a long door open time,
this allows people carrying packages enough
time to get from the Xtreme™ to the door and
open it before the timer runs out. Other people may only require a few seconds to do the same task,
without an auto re-lock, the door would be left unlocked long enough for people to tailgate in behind
you. No programming is necessary. After a valid access or egress, the programming control moni-
tors the door contact, sees the door switch open and drops the main relay immediately. Disengaging
the lock, which you will notice always locking behind you, whether you take three seconds to get to
the door or ten seconds. NOTE: This feature requires that you utilize the normally closed door
contact (input) per diagram B.
To alarm panel
To alarm panel
Basic Access Control with an Electromagnetic Lock
Integrated Access
Control with an
Electromagnetic Lock
Integrated Access
Control with an
Electric Door
Strike
Basic Access Control with an Electric Door Strike
Normally
Open SwitchNormally Closed
Door Contacts
Input Loop Common
Door Position Input
Timed Egress Input
White/Orange
White
Brown
Programming
SwitchSW1
TS1
-Jumper on 2&3 for
12-15 VDC only
-Jumper on 1&2 for
15-24 VDC
12-24 VAC
12 or 24 volt AC/DC
power supply
Note: If powering the key-
pad and the lock with the
same power supply, Lock
voltage must match power
supply voltage
NONC
C
NONCNONC
-Jumper on 2&3 for
12-15 VDC only
-Jumper on 1&2 for
15-24 VDC
12-24 VAC
12 or 24 volt AC/DC
power supply
NONC
C
NONCNONC
-Jumper on 2&3 for
12-15 VDC only
-Jumper on 1&2 for
15-24 VDC
12-24 VAC
12 or 24 volt AC/DC
power supply
NONC
12 or 24 volt AC/DC
power supply
C C
Magnetic Door Lock
( Fail Safe )
C C
C
C
C
NONCNONC
Normally
Open SwitchNormally Closed
Door Contacts
Input Loop Common
Door Position Input
Timed Egress Input
White/Orange
White
Brown
Programming
SwitchSW1
TS1
Electric door strike
-Jumper on 2&3 for
12-15 VDC only
-Jumper on 1&2 for
15-24 VDC
12-24 VAC
Normally
Open SwitchNormally Closed
Input Loop Common
Door Position Input
Timed Egress Input
White/Orange
White
Brown
Programming
Switch
To alarm
panel closed
circuit loop
NONC
C
C
C
NONCNONC
Magnetic door lock ( fail safe )
Normally
Open SwitchNormally Closed
Input Loop Common
Door Position Input
Timed Egress Input
White/Orange
White
Brown
Programming
Switch
To alarm
panel closed
circuit loop
Electric door strike
* If no contact in being used it
must be jumped closed.
(White/orange + White wire)
* If no contact in being used it
must be jumped closed.
(White/orange + White wire)
* If no contact in being used it
must be jumped closed.
(White/orange + White wire)
* If no contact in being used it
must be jumped closed.
(White/orange + White wire)
Note: If powering the keypad
and the lock with the same
power supply, Lock voltage must
match power supply voltage
Note: If powering the keypad
and the lock with the same
power supply, Lock voltage must
match power supply voltage
Note: If powering the keypad and
the lock with the same power sup-
ply, Lock voltage must match
power supply voltage