Locks 6111/6111DS Installation Instructions 107681
User Manual: Locks 6111/6111DS Installation Instructions Mayflower Sales - Von Duprin
Open the PDF directly: View PDF
.
Page Count: 2
| Download | |
| Open PDF In Browser | View PDF |
*931226-00*
6111/6111DS
931226-00
Electric Strike Double Door with Mullion Rim Application
Installation Instructions
Note: Check with factory for retrofit applications.
1
For lock or device preparation, see their directions. Also see application schedule on other side.
2
Prepare mullion for strike (see other side).
3
Wire strike (Figure 1). (Switches on 6111DS only.)
4
Test strike: Apply solenoid power. Fail secure (FSE) lip unlocks. Fail safe (FS) lip locks. Figure 1 shows status of switches.
5
Install strike with two #12-24 screws. Make sure clearance between latch bolt and strike lip is 1/32” (Figure 2).
6
If latch bolt does not extend far enough to actuate tripper, install extension (Figure 3). (Tripper on 6111DS only.)
7
Test door: With strike unlocked, door opens with latch bolt extended. When door closes, latch bolt rides over strike lip.
SOLENOID POWER REQUIREMENTS
Yellow solenoid wires = 12 VDC, 0.57 A
Black solenoid wires = 24 VDC, 0.29 A
(also shown on strike label)
Wiring
for DC
supply
Wiring
for AC
supply
{
{
! NOTE
12 VDC
or
DC input is
nonpolarized. 24 VDC
12 VAC
or
24 VAC
12 VDC
SO-24
24 VDC
Use crimp
connectors to
splice field wiring
to P1 leads
P1A
P2
S1
J1
SO-12
P1 J1A
J2
P1
S2
Solenoid
S1
S2
1
2
3
4
5
6
J2
Red (C)
Blue
Yellow
White (C)
Gray
Violet
Switches hown with tripper
depressed, strike lip closed and locked
(switches and tripper on 6111DS only)
1/32”
}
}
S1
(monitors
tripper)
S2
(monitors
strike lip)
P2
Fail safe (FS) Fail secure (FSE)
Figure 1
Top view;
faceplate not
shown for clarity
1
2
3
4
5
6
J2
SO-12 or SO-24
NOTE:
Static Strength Rating 1500 lb.
Dynamic Strength Rating 70ft.-lb.
Endurance Rating 250,000c.
Use crimp connectors to
splice field wiring to P2
leads; insulate unused leads
SWITCH RATINGS
Standard: 5 A, 30 VDC
Gold: 0.25 A, 30 VDC
Extension
Tripper
Strike
lip
Latch
bolt
Figure 3
Figure 2
89/336/EEC
X
Line X-X corresponds to
line X-X on device template
X
RHR shown active
LHR shown inactive
Electric strike
299 or
268 strike
5/16”
minimum
3/16”
ref.
X
“B”
“B”
Von Duprin Device
“B”
22 Rim and 98/99 Rim
3-7/16”
33/35 Rim EO/DT/NL/TP 2-13/32”
33A/35A Series Rim
2-15/32”
44/88 Rim EO/DT/NL/TP 3-1/2”
44/88 Rim K
3-3/8”
For other devices, consult factory.
X
Application Schedule
#25 drill and #10-24 tap
for 268 strike only
on DL 4854
1/2”
3/4”
4-1/2”
1-15/16”
1-1/16”
CL strike and
device
1/2”
2-5/8”
5-1/4”
1-3/32”
2-1/4”
2-1/8”
4854 or DL 4854
mullion
#25 drill and
#10-24 tap
2 places
2-3/16”
#16 drill and
#12-24 tap
2 places
3/4”
1-7/16”
Mullion Preparation for Strike
Customer Service
1-877-671-7011
www.allegion.com/us
© Allegion 2014
Printed in U.S.A.
931226-00 Rev. 01/14-c
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Create Date : 2013:12:09 21:57:32-05:00 Creator : Adobe InDesign CS6 (Windows) Modify Date : 2016:02:12 15:03:10-05:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Metadata Date : 2016:02:12 15:03:10-05:00 Creator Tool : Adobe InDesign CS6 (Windows) Instance ID : uuid:c1ed6e80-833a-4d0c-a849-f136abc412e6 Original Document ID : xmp.did:516915126ECCE1118A0D8AD340C27D6B Document ID : xmp.id:C311E3584661E31186A5BDF5B3C787E8 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:5AD9FB9F1156E3119331EDD110D6BD56 Derived From Document ID : xmp.did:48021814FF55E3119331EDD110D6BD56 Derived From Original Document ID: xmp.did:516915126ECCE1118A0D8AD340C27D6B Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Windows) History Changed : / History When : 2013:12:09 21:57:32-05:00 Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 2EXIF Metadata provided by EXIF.tools