Fire Alarm Control Panels MS-5UD Series MS-10UD Series Manual Document 52626 3/7/2014 P/N 52626:C4 Rev: C4 ECN 14-167 Fire Alarm & Emergency Communication System Limitations While a life safety system may lower insurance rates, it is not a substitute for life and property insurance! An automatic fire alarm system—typically made up of smoke detectors, heat detectors, manual pull stations, audible warning devices, and a fire alarm control panel (FACP) with remote notification capability—can provide early warning of a developing fire. Such a system, however, does not assure protection against property damage or loss of life resulting from a fire. An emergency communication system—typically made up of an automatic fire alarm system (as described above) and a life safety communication system that may include an autonomous control unit (ACU), local operating console (LOC), voice communication, and other various interoperable communication methods—can broadcast a mass notification message. Such a system, however, does not assure protection against property damage or loss of life resulting from a fire or life safety event. The Manufacturer recommends that smoke and/or heat detectors be located throughout a protected premises following the recommendations of the current edition of the National Fire Protection Association Standard 72 (NFPA 72), manufacturer's recommendations, State and local codes, and the recommendations contained in the Guide for Proper Use of System Smoke Detectors, which is made available at no charge to all installing dealers. This document can be found at http:// www.systemsensor.com/appguides/. A study by the Federal Emergency Management Agency (an agency of the United States government) indicated that smoke detectors may not go off in as many as 35% of all fires. While fire alarm systems are designed to provide early warning against fire, they do not guarantee warning or protection against fire. A fire alarm system may not provide timely or adequate warning, or simply may not function, for a variety of reasons: Smoke detectors may not sense fire where smoke cannot reach the detectors such as in chimneys, in or behind walls, on roofs, or on the other side of closed doors. Smoke detectors also may not sense a fire on another level or floor of a building. A second-floor detector, for example, may not sense a first-floor or basement fire. Particles of combustion or “smoke” from a developing fire may not reach the sensing chambers of smoke detectors because: • Barriers such as closed or partially closed doors, walls, chimneys, even wet or humid areas may inhibit particle or smoke flow. • Smoke particles may become “cold,” stratify, and not reach the ceiling or upper walls where detectors are located. • Smoke particles may be blown away from detectors by air outlets, such as air conditioning vents. • Smoke particles may be drawn into air returns before reaching the detector. The amount of “smoke” present may be insufficient to alarm smoke detectors. Smoke detectors are designed to alarm at various levels of smoke density. If such density levels are not created by a developing fire at the location of detectors, the detectors will not go into alarm. Smoke detectors, even when working properly, have sensing limitations. Detectors that have photoelectronic sensing chambers tend to detect smoldering fires better than flaming fires, which have little visible smoke. Detectors that have ionizing-type sensing chambers tend to detect fast-flaming fires better than smoldering fires. Because fires develop in different ways and are often unpredictable in their growth, neither type of detector is necessarily best and a given type of detector may not provide adequate warning of a fire. Smoke detectors cannot be expected to provide adequate warning of fires caused by arson, children playing with matches (especially in bedrooms), smoking in bed, and violent explosions 2 (caused by escaping gas, improper storage of flammable materials, etc.). Heat detectors do not sense particles of combustion and alarm only when heat on their sensors increases at a predetermined rate or reaches a predetermined level. Rate-of-rise heat detectors may be subject to reduced sensitivity over time. For this reason, the rate-of-rise feature of each detector should be tested at least once per year by a qualified fire protection specialist. Heat detectors are designed to protect property, not life. IMPORTANT! Smoke detectors must be installed in the same room as the control panel and in rooms used by the system for the connection of alarm transmission wiring, communications, signaling, and/or power. If detectors are not so located, a developing fire may damage the alarm system, compromising its ability to report a fire. Audible warning devices such as bells, horns, strobes, speakers and displays may not alert people if these devices are located on the other side of closed or partly open doors or are located on another floor of a building. Any warning device may fail to alert people with a disability or those who have recently consumed drugs, alcohol, or medication. Please note that: • An emergency communication system may take priority over a fire alarm system in the event of a life safety emergency. • Voice messaging systems must be designed to meet intelligibility requirements as defined by NFPA, local codes, and Authorities Having Jurisdiction (AHJ). • Language and instructional requirements must be clearly disseminated on any local displays. • Strobes can, under certain circumstances, cause seizures in people with conditions such as epilepsy. • Studies have shown that certain people, even when they hear a fire alarm signal, do not respond to or comprehend the meaning of the signal. Audible devices, such as horns and bells, can have different tonal patterns and frequencies. It is the property owner's responsibility to conduct fire drills and other training exercises to make people aware of fire alarm signals and instruct them on the proper reaction to alarm signals. • In rare instances, the sounding of a warning device can cause temporary or permanent hearing loss. A life safety system will not operate without any electrical power. If AC power fails, the system will operate from standby batteries only for a specified time and only if the batteries have been properly maintained and replaced regularly. Equipment used in the system may not be technically compatible with the control panel. It is essential to use only equipment listed for service with your control panel. Telephone lines needed to transmit alarm signals from a premises to a central monitoring station may be out of service or temporarily disabled. For added protection against telephone line failure, backup radio transmission systems are recommended. The most common cause of life safety system malfunction is inadequate maintenance. To keep the entire life safety system in excellent working order, ongoing maintenance is required per the manufacturer's recommendations, and UL and NFPA standards. At a minimum, the requirements of NFPA 72 shall be followed. Environments with large amounts of dust, dirt, or high air velocity require more frequent maintenance. A maintenance agreement should be arranged through the local manufacturer's representative. Maintenance should be scheduled monthly or as required by National and/or local fire codes and should be performed by authorized professional life safety system installers only. Adequate written records of all inspections should be kept. Limit-D-1-2013 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Installation Precautions Adherence to the following will aid in problem-free installation with long-term reliability: WARNING - Several different sources of power can be connected to the fire alarm control panel. Disconnect all sources of power before servicing. Control unit and associated equipment may be damaged by removing and/or inserting cards, modules, or interconnecting cables while the unit is energized. Do not attempt to install, service, or operate this unit until manuals are read and understood. CAUTION - System Re-acceptance Test after Software Changes: To ensure proper system operation, this product must be tested in accordance with NFPA 72 after any programming operation or change in site-specific software. Reacceptance testing is required after any change, addition or deletion of system components, or after any modification, repair or adjustment to system hardware or wiring. All components, circuits, system operations, or software functions known to be affected by a change must be 100% tested. In addition, to ensure that other operations are not inadvertently affected, at least 10% of initiating devices that are not directly affected by the change, up to a maximum of 50 devices, must also be tested and proper system operation verified. This system meets NFPA requirements for operation at 0-49º C/32-120º F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15-27º C/60-80º F. Verify that wire sizes are adequate for all initiating and indicating device loops. Most devices cannot tolerate more than a 10% I.R. drop from the specified device voltage. Like all solid state electronic devices, this system may operate erratically or can be damaged when subjected to lightning induced transients. Although no system is completely immune from lightning transients and interference, proper grounding will reduce susceptibility. Overhead or outside aerial wiring is not recommended, due to an increased susceptibility to nearby lightning strikes. Consult with the Technical Services Department if any problems are anticipated or encountered. Disconnect AC power and batteries prior to removing or inserting circuit boards. Failure to do so can damage circuits. Remove all electronic assemblies prior to any drilling, filing, reaming, or punching of the enclosure. When possible, make all cable entries from the sides or rear. Before making modifications, verify that they will not interfere with battery, transformer, or printed circuit board location. Do not tighten screw terminals more than 9 in-lbs. Overtightening may damage threads, resulting in reduced terminal contact pressure and difficulty with screw terminal removal. This system contains static-sensitive components. Always ground yourself with a proper wrist strap before handling any circuits so that static charges are removed from the body. Use static suppressive packaging to protect electronic assemblies removed from the unit. Follow the instructions in the installation, operating, and programming manuals. These instructions must be followed to avoid damage to the control panel and associated equipment. FACP operation and reliability depend upon proper installation. Precau-D1-9-2005 FCC Warning WARNING: This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause interference to radio communications. It has been tested and found to comply with the limits for class A computing devices pursuant to Subpart B of Part 15 of FCC Rules, which is designed to provide reasonable protection against such interference when devices are operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user will be required to correct the interference at his or her own expense. Canadian Requirements This digital apparatus does not exceed the Class A limits for radiation noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. Le present appareil numerique n'emet pas de bruits radioelectriques depassant les limites applicables aux appareils numeriques de la classe A prescrites dans le Reglement sur le brouillage radioelectrique edicte par le ministere des Communications du Canada. LiteSpeed™ is a trademark; and FireLite® Alarms is a registered trademark of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of the Microsoft Corporation. ©2014 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 3 Software Downloads In order to supply the latest features and functionality in fire alarm and life safety technology to our customers, we make frequent upgrades to the embedded software in our products. To ensure that you are installing and programming the latest features, we strongly recommend that you download the most current version of software for each product prior to commissioning any system. Contact Technical Support with any questions about software and the appropriate version for a specific application. Documentation Feedback Your feedback helps us keep our documentation up-to-date and accurate. If you have any comments or suggestions about our online Help or printed manuals, you can email us. Please include the following information: •Product name and version number (if applicable) •Printed manual or online Help •Topic Title (for online Help) •Page number (for printed manual) •Brief description of content you think should be improved or corrected •Your suggestion for how to correct/improve documentation Send email messages to: FireSystems.TechPubs@honeywell.com Please note this email address is for documentation feedback only. If you have any technical issues, please contact Technical Services. 4 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Table of Contents Section 1: Product Description ............................................................................................. 13 1.1: Product Features ..........................................................................................................................................14 1.2: Specifications...............................................................................................................................................15 1.3: Controls and Indicators................................................................................................................................20 1.4: Digital Alarm Communicator/Transmitter ..................................................................................................21 1.5: Components .................................................................................................................................................21 1.6: Optional Modules and Accessories .............................................................................................................21 1.7: Telephone Requirements and Warnings.......................................................................................................23 1.7.1: Telephone Circuitry...........................................................................................................................23 1.7.2: Digital Communicator .......................................................................................................................23 1.7.3: Telephone Company Rights and Warnings .......................................................................................24 1.7.4: For Canadian Applications ................................................................................................................24 Section 2: Installation............................................................................................................. 26 2.1: Backbox Mounting ......................................................................................................................................26 2.2: Operating Power ..........................................................................................................................................28 2.3: Input Circuits ...............................................................................................................................................30 2.4: Output Circuits.............................................................................................................................................32 2.4.1: Notification Appliance Circuits.........................................................................................................32 2.4.2: Special Application DC Power Output Connections.........................................................................33 2.4.3: Relays - Programmable .....................................................................................................................33 2.4.4: Remote Synchronization Output .......................................................................................................34 2.5: Power-limited Wiring Requirements ...........................................................................................................35 2.6: Digital Communicator .................................................................................................................................36 2.7: Installation of Optional Modules .................................................................................................................37 2.7.1: CAC-5X Class A Converter Module.................................................................................................37 Installation ............................................................................................................................................37 Wiring NACs and IDCs for Class A ....................................................................................................38 2.7.2: 4XTMF Option Module ....................................................................................................................39 4XTMF Transmitter Module Installation.............................................................................................39 2.7.3: ANN-SEC Option Card .....................................................................................................................40 2.8: ANN-BUS Devices......................................................................................................................................41 Guidelines.............................................................................................................................................41 2.8.1: ANN-BUS Wiring .............................................................................................................................41 Calculating Wiring Distance for ANN-BUS Modules.........................................................................41 Wiring Configuration ...........................................................................................................................44 Powering ANN-BUS Devices from Auxiliary Power Supply .............................................................45 2.8.2: ANN-BUS Device Addressing..........................................................................................................45 2.8.3: ANN-80(C) Remote Fire Annunciator/Indicator ..............................................................................46 Specifications .......................................................................................................................................46 Installation ............................................................................................................................................46 Opening/Closing Annunciator..............................................................................................................46 Mounting ..............................................................................................................................................47 Wiring ANN-80 to FACP.....................................................................................................................47 2.8.4: ANN-S/PG Serial/Parallel Printer Interface Installation ...................................................................48 Specifications .......................................................................................................................................49 PRN-6F Printer Installation..................................................................................................................49 2.8.5: ANN-I/O LED Driver Module ..........................................................................................................51 ANN-I/O Board Layout........................................................................................................................51 Specifications .......................................................................................................................................51 ANN-I/O Connection to FACP ............................................................................................................52 ANN-I/O Module LED Wiring ............................................................................................................52 2.8.6: ANN-LED Annunciator Module .......................................................................................................53 Specifications .......................................................................................................................................53 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 5 Table of Contents Mounting/Installation ...........................................................................................................................54 ANN-LED Board Layout and Connection to FACP ............................................................................54 2.8.7: ANN-RLY Relay Module..................................................................................................................54 Specifications........................................................................................................................................54 Mounting/Installation ...........................................................................................................................55 ANN-RLY Board Layout and Connection to FACP............................................................................56 2.9: ANN-BUS Audio Panel ...............................................................................................................................56 Section 3: Programming ........................................................................................................ 58 3.1: User Programming .......................................................................................................................................58 3.2: Initial Power-up............................................................................................................................................59 3.3: Programming Screens Description ..............................................................................................................59 3.4: Programming and Passwords.......................................................................................................................60 3.5: Master Programming Level .........................................................................................................................61 3.5.1: Input Zones ........................................................................................................................................61 3.5.2: NAC (Notification Appliance Circuit) ..............................................................................................66 Enabled .................................................................................................................................................66 NAC Coding .........................................................................................................................................67 Silence...................................................................................................................................................68 Auto Silence..........................................................................................................................................69 Silence Inhibited ...................................................................................................................................69 3.5.3: Relays ................................................................................................................................................69 3.5.4: System Setup .....................................................................................................................................69 Timers ...................................................................................................................................................70 Banner...................................................................................................................................................72 Time-Date .............................................................................................................................................72 Trouble Reminder.................................................................................................................................74 Canadian Option ...................................................................................................................................74 Charger Disable ....................................................................................................................................74 3.5.5: Option Modules ................................................................................................................................75 ANN-BUS.............................................................................................................................................75 ANN-RLY Options Screen...................................................................................................................78 ANN-AUDIO Options Screen..............................................................................................................79 ANN-SEC Enable.................................................................................................................................79 Onboard DACT ....................................................................................................................................79 3.5.6: History ...............................................................................................................................................90 View Events..........................................................................................................................................90 Erase History ........................................................................................................................................91 3.5.7: Walktest .............................................................................................................................................91 3.5.8: Clear Program ....................................................................................................................................92 Printer/PC .............................................................................................................................................92 3.5.9: Password Change...............................................................................................................................92 3.6: Maintenance Programming Level................................................................................................................93 3.6.1: Input Zones - Enable/Disable ............................................................................................................93 3.6.2: History ...............................................................................................................................................94 3.6.3: Walktest .............................................................................................................................................94 3.6.4: Time-Date ..........................................................................................................................................95 Section 4: Operating Instructions ......................................................................................... 96 4.1: Panel Control Buttons ..................................................................................................................................96 4.1.1: Acknowledge/Step .............................................................................................................................96 4.1.2: Alarm Silenced ..................................................................................................................................96 4.1.3: Drill/Hold 2 Sec .................................................................................................................................96 4.1.4: Reset ..................................................................................................................................................96 4.2: LED Indicators.............................................................................................................................................96 4.3: Normal Operation ........................................................................................................................................97 4.4: Trouble Operation ........................................................................................................................................97 4.5: Alarm Operation ..........................................................................................................................................99 6 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Table of Contents 4.6: Supervisory Operation .................................................................................................................................99 4.7: Process Monitor Operation ........................................................................................................................100 4.8: Hazard/Tornado Condition Operation .......................................................................................................100 4.9: Medical Alert Condition Operation ...........................................................................................................101 4.10: Disable/Enable Operation ........................................................................................................................101 4.11: Waterflow Circuits Operation ..................................................................................................................101 4.12: Detector Functions...................................................................................................................................102 4.13: Time Functions: Real-Time Clock...........................................................................................................102 4.14: Coded Operation ......................................................................................................................................102 4.15: Presignal ..................................................................................................................................................102 4.16: Positive Alarm Sequence .........................................................................................................................103 4.17: Special System Timers.............................................................................................................................103 4.17.1: Silence Inhibit Timer .....................................................................................................................103 4.17.2: Autosilence Timer .........................................................................................................................103 4.17.3: Trouble Reminder..........................................................................................................................103 4.17.4: Waterflow Retard Timer................................................................................................................104 4.17.5: Alarm Verification (None or One Minute)....................................................................................104 4.18: Walktest ...................................................................................................................................................104 4.19: Read Status ..............................................................................................................................................105 4.19.1: Input Zones ....................................................................................................................................105 4.19.2: NAC...............................................................................................................................................106 4.19.3: Relays ............................................................................................................................................106 4.19.4: System Settings .............................................................................................................................107 4.19.5: Timers............................................................................................................................................107 4.19.6: Daylight Savings ...........................................................................................................................107 4.19.7: History ...........................................................................................................................................107 4.19.8: Print ...............................................................................................................................................107 4.19.9: ANN-BUS .....................................................................................................................................108 4.19.10: Central Station .............................................................................................................................108 4.19.11: Phone Line...................................................................................................................................109 4.19.12: Service Terminal..........................................................................................................................109 Section 5: Central Station Communications ...................................................................... 110 5.1: Transmittal Priorities ................................................................................................................................. 111 Section 6: Local/Remote Site Upload/Download ............................................................... 113 6.1: Remote Download .....................................................................................................................................113 6.2: Transferring a Program ..............................................................................................................................114 6.2.1: Security Features .............................................................................................................................114 Section 7: Power Supply Calculations................................................................................ 116 7.1: Overview....................................................................................................................................................116 7.2: Calculating the AC Branch Circuit............................................................................................................116 7.3: Calculating the System Current Draw .......................................................................................................117 7.3.1: Overview .........................................................................................................................................117 7.3.2: How to Use Table 7.3 on page 118 to Calculate System Current Draw .........................................117 7.4: Calculating the Battery Size ......................................................................................................................119 7.4.1: NFPA Battery Requirements ...........................................................................................................119 7.4.2: Selecting and Locating Batteries .....................................................................................................119 Appendix A: Ademco Contact ID Format Event Code Descriptions................................ 120 A.1: Transmission Format Between DACT and Receiver................................................................................120 A.2: Ademco Contact ID Typical Printout .......................................................................................................120 Appendix B: NFPA Standard-Specific Requirements ....................................................... 125 B.1: Central Station/Remote Station Transmitter: Connection to FACP Dry Contacts....................................130 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 7 Table of Contents Appendix C: FACP with Keltron .......................................................................................... 131 Appendix D: Wire Requirements......................................................................................... 132 D.1: MS-5UD-3(E) & MS-10UD-3(E) NAC Wiring .......................................................................................132 D.2: MS-5UD-7(C/E) & MS-10UD-7(C/E) NAC Wiring................................................................................133 Appendix E: Default Programming ..................................................................................... 134 Appendix F: Canadian Application ..................................................................................... 136 F.1: ANN-LED Annunciator Installation for Canadian Applications...............................................................136 Index ...................................................................................................................................... 138 8 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 It is imperative that the installer understand the requirements of the Authority Having Jurisdiction (AHJ) and be familiar with the standards set forth by the following regulatory agencies: • Underwriters Laboratories/Underwriters Laboratories Canada • National Fire Protection Association Before proceeding, the installer should be familiar with the following documents. NFPA Standards This Fire Alarm Control Panel complies with the following NFPA Standards: NFPA 72 National Fire Alarm Code for Local Fire Alarm Systems and Remote Station Fire Alarm Systems (requires an optional Remote Station Output Module) Underwriters Laboratories Documents for Reference: UL 38 Manually Actuated Signaling Boxes UL 217 Smoke Detectors, Single and Multiple Station UL 228 Door Closers–Holders for Fire Protective Signaling Systems UL 268 Smoke Detectors for Fire Protective Signaling Systems UL 268A Smoke Detectors for Duct Applications UL 346 Waterflow Indicators for Fire Protective Signaling Systems UL 464 Audible Signaling Appliances UL 521 Heat Detectors for Fire Protective Signaling Systems UL 864 Standard for Control Units for Fire Protective Signaling Systems UL 1481 Power Supplies for Fire Protective Signaling Systems UL 1638 Visual Signaling Appliances UL 1971 Signaling Devices for Hearing Impaired UL 2017 General-Purpose Signaling Devices and Systems CAN/ULC - S524-01 Standard for Installation of Fire Alarm Systems CAN/ULC - S559 Standard for Equipment for Fire Signal Receiving Centers and Systems This Class (A) digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe (A) est conforme à la norme NMB-003 du Canada. Other: Canadian Electrical Code, Part I NEC Article 250 Grounding NEC Article 300 Wiring Methods NEC Article 760 Fire Protective Signaling Systems Applicable Local and State Building Codes Requirements of the Local Authority Having Jurisdiction (LAHJ) Fire•Lite Documents Fire•Lite Device Compatibility Document Document #15384 CHG-120F Battery Charger Manual Document #50888 CHG-75 Battery Charger Manual Document #51315 411UD Manual Document #50759 411UDAC Manual Document #51073 ANN-80 Product Installation Doc. Document #52749 ANN-(R)LED Product Installation Doc. Document #53032 ANN-I/O Product Installation Doc. Document #151416 ANN-RLY Product Installation Doc. Document #53033 ANN-S/PG Product Installation Doc. Document #151417 ACC-25/50 Series Audio Panel Document #51889 This product has been certified to comply with the requirements in the Standard for Control Units and Accessories for Fire Alarm Systems, UL 864, 9th Edition. Operation of this product with products not tested for UL 864, 9th Edition has not been evaluated. Such operation requires the approval of the local Authority Having Jurisdiction (AHJ). MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 9 10 Power Supply Connector For more specific UL wiring information, refer to page 35. Nonresettable or Resettable Power { 2 Jumper selectable by JP31, 24 VDC 1 filtered, power-limited (0.5 amp maximum). Supervision required. Nonresettable Power suitable for powering smoke detectors. Configure TB9, Terminals 1 & 2 as Resettable or Nonresettable Power. • Resettable Power - jumper JP31 pins 2 &3 • Nonresettable Power - jumper JP31 pins 1 & 2 (as shown) Resettable Power - 24 VDC filtered, power-limited (0.5 amp maximum) to 4 smoke detectors (IDC). Supervision { 3 required. Nonsupervised, power-limited circuits Supervise with a power supervision relay EOLR-1 Special Application DC Power Outputs 24 VDC) Important! Removing Ground Fault Disable Jumper JP43 voids UL/NFPA Style/Class indentifications for circuits. Remove jumper JP43 only with the approval of the local AHJ (Authority Having Jurisdiction). Notes: 1. MS-5UD-3(E) = 2.5 amps max. per NAC MS-5UD-7(C/E)= 3 amps max. per NAC 2. Remote Sync Output is required only for the MS-5UD-3(E): Refer to “Remote Synchronization Output” on page 34. 3. 18 Amp Hour max. for MS-5UD-3(E) 26 Amp Hour max. for MS-5UD-7(E) 18 Amp Hour max. for MS-5UD-7C Basic System Connections 5-Zone Panel Notification Appliance Circuits (see note 1) NAC #3 NAC #4 24 VDC, supervised, nonpower-limited Battery (see note 3) Remove jumper JP43 to disable Ground Fault Detection circuit (only with approval of AHJ) Class A Converter Module Special Application Power IDCs 1 through 5, Style B (Class B) (Supervised, Power-Limited) (See Style D illustrated near right edge of board.) 4.7Kohm, ½ watt End-ofLine Resistor PN 71252 Initiating Device Circuits NAC #1 NAC #2 Special Application Power NAC #1, #2, #3, & #4, Style Y (Class B) (Supervised, PowerLimited) (See Style Z illustrated near right edge of board.) 4.7Kohm, ½ watt End-of-Line Resistor PN 71252 SW1 Secondary Secondary Phone Active LED Nonpower-Limited DACT Phone Line Jacks Primary Primary Phone Active LED ANN-SEC option card connector Cut this jumper to supervise the 4XTMF module when installed (see J4 & J5) Auxiliary Trouble Input Kiss-off LED Cut this jumper to enable Supervisory Relay when 4XTMF module is installed Alarm* Trouble* Supervisory* (*Factory default relay programming) A Fail Safe Trouble relay switches to the NC position during trouble conditions and under loss of all power. USB port for local programming using a personal computer and PK-5X Utility Class A Converter Module Style D (Class A) IDC Dummy load all unused circuits with 4.7K, ½ watt End-of-Line resistors Contacts shown below in normal condition (AC power with no alarm, Style Z (Class A) NAC trouble, or supervisory activity) Push switch down to upgrade software Special Application Power 24 VDC filtered, supervised, and powerlimited. 0.040 amp maximum. Requires 4.7K ohm ELR. Remote Synchronization Output (see note 2) 3 Programmable Relays Nonsupervised relay contacts Contact Ratings 2.0 amps @ 30 VDC (resistive) 0.5 amp @ 30 VAC (resistive) MS-5UD Series Main Circuit Board ms-5udlayout.wmf MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Power Supply Connector For more specific UL wiring information, refer to page 35. Nonresettable or Resettable Power { 2 Jumper selectable by JP31, 24 VDC 1 filtered, power-limited (0.5 amp maximum). Supervision required. Nonresettable Power suitable for powering smoke detectors. Configure TB9, Terminals 1 & 2 as Resettable or Nonresettable Power. • Resettable Power - jumper JP31 pins 2 &3 • Nonresettable Power - jumper JP31 pins 1 & 2 (as shown) Resettable Power - 24 VDC filtered, power-limited (0.5 amp maximum) to 4 smoke detectors (IDC). Supervision { 3 required. Nonsupervised, power-limited circuits Supervise with a power supervision relay EOLR-1 Special Application DC Power Outputs 24 VDC) Important! Removing Ground Fault Disable Jumper JP43 voids UL/NFPA Style/Class indentifications for circuits. Remove jumper JP43 only with the approval of the local AHJ (Authority Having Jurisdiction). Notes: 1. MS-10UD-3(E) = 2.5 amps max. per NAC MS-10UD-7(C/E) = 3 amps max. per NAC 2. Remote Sync Output is required only for the MS-10UD-3(E): refer to “Remote Synchronization Output” on page 34. 3. 18 Amp Hour max. for MS-10UD-3(E) 26 Amp Hour max. for MS-10UD-7(E) 18 Amp Hour max. for MS-10UD-7C Basic System Connections 10-Zone Panel Notification Appliance Circuits (see note 1) ZONE 6 TB6 SW1 Auxiliary Trouble Input Kiss-off LED Cut this jumper to enable Supervisory Relay when 4XTMF module is installed Nonpower-Limited 24 VDC, supervised, nonpower-limited Secondary Battery (see note 3) Primary Primary Phone Active LED Secondary Phone Active LED Cut this jumper to supervise the 4XTMF module when installed (see J4 & J5) Push switch down to upgrade software ZONE ZONE 10 9 ANN-SEC option card connector ZONE 8 (*Factory default relay programming) A Fail Safe Trouble relay switches to the NC position during trouble conditions and under loss of all power. Contacts shown below in normal condition (AC power with no alarm, trouble, or supervisory activity) Alarm* Trouble* Supervisory* Dummy load all unused circuits with 4.7K, ½ watt End-of-Line resistors 1/6 2/7 3/8 4/9 5/10 USB port for local programming using a personal computer and PK-5X Utility Class A Converter Module TB4/ TB6 Style D (Class A) IDC Style Z (Class A) NAC 3 Programmable Relays Nonsupervised relay contacts Contact Ratings 2.0 amps @ 30 VDC (resistive) 0.5 amp @ 30 VAC (resistive) DACT Phone Line Jacks Remove jumper JP43 to disable Ground Fault Detection circuit (only with approval of AHJ) ZONE 7 Special Application Power 24 VDC filtered, supervised, and power-limited. 0.040 amp maximum. Requires 4.7K ohm ELR. Remote Synchronization Output (see note 2) Special Application Power IDCs 1 through 5, Style B (Class B) (Supervised, PowerLimited) (See Style D illustrated near right edge of board.) 4.7Kohm, ½ watt End-of-Line Resistor PN 71252 Initiating Device Circuits 6 6 Class A Converter Module Special Application Power IDCs 1 through 5, Style B (Class B) (Supervised, Power-Limited) (See Style D illustrated near right edge of board.) 4.7Kohm, ½ watt End-ofLine Resistor PN 71252 4 4 NAC #3 NAC #4 Initiating Device Circuits NAC #1 NAC #2 Special Application Power NAC #1, #2, #3, & #4, Style Y (Class B) (Supervised, PowerLimited) (See Style Z illustrated near right edge of board.) 4.7Kohm, ½ watt End-of-Line Resistor PN 71252 MS-10UD Series Main Circuit Board ms-10udlayout.wmf 11 ANN-S/PG Printer Driver Doc. # ANN-I/O LED Driver Doc. # ANN-80(C) LCD Text Annunciator/Indicator Doc. # SW1 JP2 1 2 3 4 5 6 7 8 J1 Alarm Silenced P1 P2 P3 NAC 1 Fault Earth Fault ZONE 1 P4 NAC2 Fault Battery Fault ZONE 2 ALM Charger Fault ZONE 3 ALM ALM NAC 3 Fault NAC 4 Fault Disabled ALM ZONE 4 ALM ZONE 5 TB2 TBL ACK 1 10 11 20 21 30 31 40 SUP TB4 P ST E ALM TBL TB5 ALARM TBL SUP ALM 6 1 2 3 4 5 SUP 1 ZONE 6 TBL SUP 2 TBL SUP ZONE 7 ALM 7 TBL SUP 3 ZONE 8 8 TBL SUP ALM TBL SUP 4 ZONE 9 9 TBL SUP 5 ALM TBL SUP FIRE ALARM ANNUNCIATOR TROUBLE TB3 ANN-(R)LED LED Display Doc. # FIRE ALARM ANNUNCIATOR TB6 ANN-BUS TB1 ANN-RLY 10 Form-C Relay Card Doc. # CN2 ANN-BUS - TB3 P4 FROM AP P5 PHONE P6 PSTN P7 TO A P P8 OUT NC P9 OU T NO P10 INPUT P11 TAMPER P12 GND +12/24V IPDACT Internet Communicator Doc. #53109 J8 & J9 Telephone Connections 6 5 POWER LIMITED 1 TB1 7 4XTM Reverse Polarity Module J2 Sw1 TBL J1 J4 & J5 Local PC USB 510udperi.wmf Battery Connector - J12 JP1 AM-1 ENABLE CUT FOR 240VAC ENABLE AC DELAY JP3 F1 15 JP4 ADDRESS SW1 ON 12 + - F3 JP2 OFF GND FLT DISABLE TB3 A- B- A+ B+ - 16 HR DELAY 15 HOT NEUT EARTH 11 0 5 7 10 8 14 1 12 13 6 15 2 9 4 3 ONES TB2 BAT BAT OUT OUT + + - TB1 CHG-120 Charger Doc. # AM-1 F2 TENS 11 0 5 7 10 8 14 1 12 13 6 15 9 4 32 J4 JP5 TB4 J1 J2 J3 NC NO C + CHG-75 Charger Doc. # 51315 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Section 1: Product Description The MS-5UD is a five zone FACP (Fire Alarm Control Panel) and the MS-10UD is a ten zone FACP. The information in this manual refers to both the MS-5UD and MS-10UD unless otherwise specified. The combination control and digital communicator panels provide reliable fire signaling protection for small to medium sized commercial, industrial and institutional buildings. The FACP is compatible with System Sensor’s i3 detectors which are conventional smoke detectors that can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory ‘freeze’ signal when the ambient temperature falls below the detector rating of approximately 45o F (refer to System Sensor i3 Installation and Maintenance Instructions). In addition, the control panel is compatible with conventional input devices such as two-wire smoke detectors, four-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally-open contact devices. Refer to the Fire•Lite Device Compatibility Document for a complete listing of compatible devices. Outputs include four NACs (Notification Appliance Circuits), three programmable Form-C relays (factory programmed for Alarm, Trouble and Supervisory) and 24 VDC special application resettable and nonresettable power outputs. The FACP supervises all wiring, AC voltage, battery level and telephone line integrity. Available accessories include local and remote upload/download software, remote annunciators and reverse polarity/city box transmitter. The integral DACT transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. It also allows remote programming or interrogation of the control panel using the PS-Tools Upload/Download utility via the public switched telephone network. Local programming interrogation is also possible using the PS-Tools and the USB port on the FACP. Any personal computer with Windows® XP or newer, compatible modem with a speed of 2400 baud and PS-Tools may serve as a Service Terminal. This allows download of the entire program or upload of the entire program, history file, walktest data and current status. Activation of a compatible smoke detector or any normally-open fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicating LED, display alarm information on the panel’s LCD, sound the piezo sounder at the FACP, activate the FACP alarm relay and operate an optional module used to notify a remote station or initiate an auxiliary control function. MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 13 Product Description Product Features The following versions of the MS-5UD and MS-10UD are available: FACP Version Description MS-5UD-3 Five Zone Panel: 120 VAC with FLPS-3 power supply providing 3.0 amps total 24 VDC output current MS-5UD-7 Five Zone Panel: 120 VAC with FLPS-7 power supply providing 7.0 amps total 24 VDC output current MS-5UD-7C Five Zone Panel: 120 VAC with FLPS-7 power supply providing 7.0 amps total 24 VDC output current. Includes built-in ANN-LED Annunciator. This panel is approved for Canadian applications MS-5UD-3E Five Zone Panel: 240 VAC with FLPS-3 power supply providing 3.0 amps total 24 VDC output current MS-5UD-7E Five Zone Panel: 240 VAC with FLPS-7 power supply providing 7.0 amps total 24 VDC output current MS-10UD-3 Ten Zone Panel: 120 VAC with FLPS-3 power supply providing 3.0 amps total 24 VDC output current MS-10UD-3E Ten Zone Panel: 240 VAC with FLPS-3 power supply providing 3.0 amps total 24 VDC output current MS-10UD-7 Ten Zone Panel: 120 VAC with FLPS-7 power supply providing 7.0 amps total 24 VDC output current MS-10UD-7C Ten Zone Panel: 120 VAC with FLPS-7 power supply providing 7.0 amps total 24 VDC output current. Includes built-in ANN-LED Annunciator. This panel is approved for Canadian applications. MS-10UD-7E Ten Zone Panel: 240 VAC with FLPS-7 power supply providing 7.0 amps total 24 VDC output current NOTE: Unless otherwise specified, the information in this manual applies to all versions of the panels. 1.1 Product Features • Built-in DACT (Digital Alarm Communicator/Transmitter) • Style B (Class B) IDC (Initiating Device Circuit) MS-5UD - five programmable IDCs MS-10UD - ten programmable IDCs • Four Style Y (Class B) NAC (Notification Appliance Circuit) special application power • Three programmable Form-C relays • Built-in Programmer • Touchtone/Rotary dialing • Programmable Make/Break Ratio • Optional Dress Panel: DP-51050 • A modified Dress Panel is provided standard with Canadian models: includes an ANN-LED Annunciator module • Optional Trim Ring TR-CE (red) for semi-flush mounting the cabinet • ANN-BUS for connection to optional: ANN-80 Remote LCD Annunciator ANN-I/O LED Driver ANN-S/PG Printer Module 14 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Specifications Product Description ANN-RLY Relay Module ANN-LED Annunciator Module • 80-character LCD display (backlit) • Real-time clock/calendar with daylight savings time control • History log with 256 event storage • Control Buttons ACK (Acknowledge) Alarm Silence System Reset/Lamp Test Drill • LED Indicators Fire Alarm Supervisory Trouble AC Power Alarm Silence Primary and Secondary Phone Line Active LEDs • Piezo sounder for alarm, trouble and supervisory • 24 volt operation • Low AC voltage sense • Alarm Verification • NACs Programmable for: Silence Inhibit Auto-Silence Strobe Synchronization (System Sensor, Wheelock, Gentex, Faraday, Amseco) Selective Silence (horn-strobe mute) Temporal or Steady Signal Silenceable or Nonsilenceable • Automatic battery charger with charger supervision • Silent or audible walktest capabilities • Optional PK-CD (contains PS-Tools utility) for local or remote Upload/Download of program and data • Optional CAC-5X Class A Converter Module for NACs and IDCs • Optional 4XTMF Transmitter Module • Optional ANN-SEC card for a secondary ANN-BUS 1.2 Specifications NOTE: For wiring specifications, refer to“Wire Requirements” on page 132. AC Power MS-5UD-3 (FLPS-3 Power Supply): 120 VAC, 60 HZ, 1.00 amps MS-5UD-7 (FLPS-7 Power Supply): 120 VAC, 60 HZ, 3.90 amps MS-5UD-7C (FLPS-7 Power Supply): 120 VAC, 60 HZ, 3.90 amps MS-10UD-3 (FLPS-3 Power Supply): 120 VAC, 60 HZ, 1.00 amps MS-10UD-7 (FLPS-7 Power Supply): 120 VAC, 60 HZ, 3.90 amps MS-10UD-7C (FLPS-7 Power Supply): 120 VAC, 60 HZ, 3.90 amps MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 15 Product Description Specifications MS-5UD-3E (FLPS-3 Power Supply): 240 VAC, 50 HZ, 0.54 amps MS-5UD-7E (FLPS-7 Power Supply): 240 VAC, 50 HZ, 2.20 amps MS-10UD-3E (FLPS-3 Power Supply): 240 VAC, 50 HZ, 0.54 amps MS-10UD-7E (FLPS-7 Power Supply): 240 VAC, 50 HZ, 2.20 amps Wire size: minimum #14 AWG (2.0 mm2) with 600V insulation Supervised, nonpower-limited Battery (sealed lead acid only) - J12 Maximum Charging Circuit - Normal Flat Charge: 27.6 VDC @ 1.4 amp Supervised, nonpower-limited Maximum Charger Capacity: 18 Amp Hour battery for MS-5UD-3(E), MS-5UD-7C, MS-10UD3(E), and MS-10UD-7C, and 26 Amp Hour battery for MS-5UD-7(E) and MS-10UD-7(E) [two 18 Amp Hour batteries can be housed in FACP cabinet. Larger batteries require a separate battery box such as the BB-26 or BB-55F and the CHG-75 or CHG-120F Battery Charger.] Minimum Battery Size: 7 Amp Hour (12 Amp Hour for MS-5UD-7C & MS-10UD-7C) Initiating Device Circuits - TB4 (and TB6 on MS-10UD only) Alarm Zones 1 - 5 on TB 4 (MS-5UD and MS-10UD) Alarm Zones 6 - 10 on TB6 (MS-10UD only) Supervised and power-limited circuitry Operation: All zones Style B (Class B) Normal Operating Voltage: Nominal 20 VDC Alarm Current: 15 mA minimum Short Circuit Current: 40 mA max. Maximum Loop Resistance: 100 ohms (700 ohms per zone for linear heat detection - See Section 2.3, “Input Circuits” for more information.) End-of-Line Resistor: 4.7K, 1/2 watt (Part #71252) Standby Current: 2 mA Refer to the Fire•Lite Device Compatibility Document for listed compatible devices Notification Appliance Circuit(s) - TB5 and TB7 Four NACs Operation: Style Y (Class B) Special Application power Supervised and power-limited circuitry Normal Operating Voltage: Nominal 24 VDC Maximum Signaling Current: 3.0 amps for MS-5UD-3(E), MS-10UD-3(E) (2.5 amp maximum per NAC); 7.0 amps for MS-5UD-7(E), MS-10UD-7(E) (3.0 amps maximum per NAC) End-of-Line Resistor: 4.7K, 1/2 watt (Part #71252) Refer to the Fire•Lite Device Compatibility Document for compatible listed devices Form-C Relays - Programmable - TB8 Relay 1 (factory default programmed as Alarm Relay) Relay 2 (factory default programmed as fail-safe Trouble Relay) Relay 3 (factory default programmed as Supervisory Relay) Relay Contact Ratings: 2 amps @ 30 VDC (resistive), 0.5 amps @ 30 VAC (resistive) Special Application Resettable Power - TB9 Operating Voltage: Nominal 24 VDC Maximum Available Current: 500 mA - appropriate for powering 4-wire smoke detectors Power-limited Circuitry Refer to the Fire•Lite Device Compatibility Document for compatible listed devices 16 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Specifications Product Description Special Application Resettable or Nonresettable Power - TB9 Operating Voltage: Nominal 24 VDC Maximum Available Current: 500 mA Power-limited Circuitry Jumper selectable by JP31 for resettable or nonresettable power: Jumper pins 1 & 2 on JP31 for nonresettable power Jumper pins 2 & 3 on JP31 for resettable power Refer to the Fire•Lite Device Compatibility Document for compatible listed devices Special Application Primary ANN-BUS Power - TB3 Operating voltage: Nominal 24 VDC Maximum Available Current: 500mA Power-limited circuit Special Application Secondary ANN-BUS Power - ANN-SEC - TB1 Operating voltage: Nominal 24 VDC Maximum Available Current: 500mA Power-limited circuit Remote Sync Output - TB2 Remote power supply synchronization output, only required for the MS-5UD-3(E), MS-10UD3(E) (refer to“Remote Synchronization Output” on page 34) 24 VDC nominal special application power Maximum current is 40 mA End-of-Line Resistor: 4.7K Supervised and power-limited circuit Auxiliary Trouble Input - J6 The Auxiliary Trouble Input is an open collector circuit which can be used to monitor an external device for trouble conditions. It can be connected to the trouble bus of a peripheral, such as a power supply, which is compatible with open collector circuits. All connections must be in conduit, less than 20 ft. (610 cm) in length in the same room. MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 17 Product Description Specifications The following figure illustrates the maximum current that is possible for each major panel output circuit and the total current available from the FACP with the FLPS-3 power supply. This applies to the MS-5UD-3, MS-10UD-3, MS-5UD-3E, and MS-10UD-3E. TB9 Special Application Nonresettable or Resettable Power 0.5 amp max per circuit Special Application Resettable Power 0.5 amp max Standby 1.0 amp max per circuit per panel TB5 2.5 amps max NAC #1 per circuit NAC #2 2.5 amps max per circuit TB7 2.5 amps max NAC #3 per circuit NAC #4 2.5 amps max Alarm 3.0 amps max per circuit per panel TB3 Primary ANN-BUS 0.5 amp max per circuit TB1 Standby 1.0 amp max per panel ANN-SEC Option Card 0.5 amp max per circuit TB2 0.040 amp max per circuit powerdist510.wmf Remote Synchronization Output Refer to the battery calculations section for additional information. Figure 1.1 Current Availability with FACP and FLPS-3 Power Supply 18 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Specifications Product Description The following figure illustrates the maximum current that is possible for each major panel output circuit and the total current available from the FACP with the FLPS-7 power supply. This applies to the MS-5UD-7, MS-5UD-7C, MS-10UD-7, MS-10UD-7C, MS-5UD-7E, and MS-10UD-7E. TB9 Special Application Nonresettable or Resettable Power 0.5 amp max per circuit Special Application Resettable Power Standby 1.0 amp max 0.5 amp max per panel per circuit TB5 3.0 amps max NAC #1 per circuit NAC #2 3.0 amps max per circuit TB7 3.0 amps max NAC #3 per circuit NAC #4 Alarm 7.0 amps max 3.0 amps max per circuit per panel TB3 Primary ANN-BUS 0.5 amp max per circuit Standby 1.0 amp max TB1 per panel ANN-SEC Option Card 0.5 amp max Refer to the battery calculations section for additional information. powerdistmrp.wmf per circuit Figure 1.2 Current Availability with FACP and FLPS-7 Power Supply MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 19 Product Description Controls and Indicators 1.3 Controls and Indicators LCD Display The FACP uses an 80-character (4 lines X 20 characters) high viewing angle LCD display. The display includes a long life LED backlight that remains illuminated. If AC power is lost and the system is not in alarm, the LED backlight will turn off to conserve batteries. SYSTEM ALL NORMAL 10:00A 012105 Key Panel Mounted on the main circuit board, the key panel includes a window for the LCD display and LED indicators as listed above. The key panel, which is visible with the cabinet door closed, has 25 keys, including a 16 key alpha-numeric pad similar to a telephone keypad. Service/program keys: • Keys labeled 1 to 9 • * key • # key • 0 (recall) key • 1st Event key • Clear key • Escape key • Mode key • Four cursor keys (up, down, left and right) • Enter key 9050udkypd.cdr Function keys: • Acknowledge/Step • Alarm Silence • Drill • System Reset (lamp test) Figure 1.3 Membrane/Display Panel LED Indicators LEDs are provided to annunciate the following conditions: • • • • • • • • Fire Alarm - red LED Supervisory - yellow LED AC Power - green LED System Trouble - yellow LED Alarm Silence - yellow LED Primary Phone Line Active (on circuit board) - red LED Secondary Phone Line Active (on circuit board) - red LED Kiss-off (on circuit board) - green LED Local Piezo Sounder A piezo sounder provides separate and distinct sounds for alarm, trouble, maintenance, process monitor and supervisory conditions as follows: • • • • • 20 Alarm - on steady Trouble - pulse 1 second on and 1 second off Maintenance - pulse 1 second on and 1 second off Supervisory - pulse ½ second on and ½ second off Process Monitor - pulse ¼ second on and ¼ second off MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Digital Alarm Communicator/Transmitter Product Description 1.4 Digital Alarm Communicator/Transmitter Two modular phone jacks allow easy connection to telephone lines. Modular jacks are labeled PH1 for Primary Phone Line and PH2 for Secondary Phone Line. Two telephone line active red LEDs are provided as well as a green Kissoff LED. The integral digital communicator provides the following functions: • Line Seizure: takes control of the phone lines disconnecting any premises phones • Off/On Hook: performs on and off-hook status to the phone lines • Listen for dial tone: 440 Hz tone typical in most networks • Dialing the Central Station(s) number: default is Touch-Tone®, programmable to rotary • For tone burst or touchtone type formats: discern proper Ack and Kissoff tone(s). The frequency and time duration of the tone(s) varies with the transmission format. The control panel will adjust accordingly. • Communicate in the following formats: Ademco Contact ID SIA-DCS-8 SIA-DCS-20 1.5 Components Main Circuit Board The main circuit board contains the system’s CPU, DACT and other primary components and wiring interface connectors. Optional modules plug in and are mounted to the main circuit board. Power Supply One power supply is provided standard with each FACP, mounted to a chassis. • FLPS-3 for the MS-5UD-3(E), MS-10UD-3(E) • FLPS-7 for the MS-5UD-7(C/E), MS-10UD-7(C/E) Cabinet The backbox measures 16.65” (42.29 cm) x 19.0” (48.26 cm) x 5.207” (13.23 cm) and provides space for two batteries (up to 18 Amp Hours). Also available are an optional dress panel (DP51050) which mounts inside the cabinet and trim-ring (TR-CE). The Canadian version is supplied standard with a modified dress panel and one ANN-LED annunciator module. Batteries The cabinet provides space for two 18 Amp Hour batteries (larger batteries require use of a UL listed battery box such as the BB-26 or BB-55). Batteries must be ordered separately. 1.6 Optional Modules and Accessories CAC-5X Class A Converter Module The CAC-5X Module can be used to convert the Style B (Class B) Initiating Device Circuits to Style D (Class A) and Style Y (Class B) Notification Appliance Circuits to Style Z (Class A). The module connects to J2 on the MS-5UD and MS-10UD main circuit board and to J7 on the MS10UD. Note that two Class A Converter modules are required for the 10 zone panel. 4XTMF Transmitter Module The 4XTMF provides a supervised output for local energy municipal box transmitter and alarm and trouble reverse polarity. It includes a disable switch and disable trouble LED. A module jumper option allows the reverse polarity circuit to open with a system trouble condition if no alarm condition exists. The 4XTMF mounts to the main circuit board connectors J4 & J5. MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 21 Product Description Optional Modules and Accessories ANN-80 LCD Annunciator The ANN-80 is a remote LCD annunciator which mimics the information displayed on the FACP LCD display and provides remote RESET, SILENCE, ACKNOWLEDGE, and DRILL. ANN-80C LCD Indicator (Canadian applications) The ANN-80C is a remote LCD indicator which mimics the information displayed on the FACP LCD display but does not allow remote control of the FACP. ANN-LED Annunciator Module The ANN-LED Annunciator Module provides three LEDs for each zone: Alarm, Trouble and Supervisory. ANN-LED module is installed in dress panel for Canadian version. ANN-RLY Relay Module The ANN-RLY Module, which can be mounted inside the cabinet, provides 10 Form-C relays. ANN-S/PG Serial/Parallel Printer Gateway The ANN-S/PG module provides a connection for a serial or parallel printer. ANN-I/O LED Driver Module The ANN-I/O module provides connections to a user supplied graphic annunciator. ANN-SEC Secondary ANN-BUS Module The ANN-SEC module provides another ANN-BUS port for more wiring flexibility and for Canadian applications requiring remote annunciation. DP-51050 Dress Panel A dress panel DP-51050 is available as an option. The dress panel restricts access to the system wiring while allowing access to the membrane switch panel. The Canadian version is supplied standard with a modified dress panel. TR-CE Trim-ring A trim-ring TR-CE is available as an option. The trim-ring allows semi-flush mounting of the cabinet. Battery Box The BB-26 or BB-55F battery box may be used to house two batteries greater than 18 Amp Hour. The battery box mounts directly below the control panel cabinet, centered to the main circuit board. Battery Charger CHG-75 Battery Charger The CHG-75 is capable of charging up to 75 AH lead-acid batteries with the FACP. The FACP battery charger must be disabled, through software programming, when using the CHG-75. The charger and up to 26 AH batteries can be housed in the BB-26 battery box. Larger batteries and the charger can be housed in the BB-55F battery box which can be mounted up to 20 feet away from the control panel. Refer to the CHG-75 Manual for additional information. CHG-120F Battery Charger The CHG-120F is capable of charging up to 120 AH lead-acid batteries with the FACP. The FACP battery charger must be disabled, through software programming, when using the CHG-120F. The batteries and charger can be housed in the BB-55F battery box which can be mounted up to 20 feet away from the control panel. Note that when using a BB-55F for housing the charger and batteries greater than 26AH, multiple BB-55Fs are required. Refer to the CHG-120F Manual for additional information. 22 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Telephone Requirements and Warnings Product Description PS-Tools Programming Utility The PS-Tools Programming Utility can be used to locally or remotely program the FACP directly from most IBM compatible personal computers (PC), running Windows® XP (or newer). FACP program files can also be created and stored on the PC and then downloaded later to the control panel. The P/N: PK-CD includes the Windows-based Programming Utility software on CD-ROM with on-line help file. A standard USB cable with male-A to male-B connectors, which must be purchased separately, is required for local connection of the PC to the USB port J11 on the FACP main circuit board. Remote programming requires that the PC have a 2400 baud (or faster) modem. Important: Remote modification of FACP programming requires that the panel be enabled for remote download (refer to “Remote Download” on page 113). Remote interrogation of panel programming, history logs, detector status, etc., is possible without enabling the remote download option. 1.7 Telephone Requirements and Warnings 1.7.1 Telephone Circuitry Ringer Equivalence Number (REN) = 0.0B AC Impedance: 10.0 Mega Ohm Complies with FCC Part 68 Mates with RJ31X Male Connector Supervision Threshold: loss of phone line voltage for 2 minutes The REN is used to determine the quantity of devices which may be connected to the telephone line. Excessive RENs on the telephone line may result in the devices not ringing in response to an incoming call. In most, but not all areas, the sum of the RENs should not exceed five (5.0). To be certain of the number of devices that may be connected to the line as determined by the total RENs, contact the telephone company to determine the maximum REN for the calling area. 1.7.2 Digital Communicator Before connecting the control panel to the public switched telephone network, the installation of two RJ31X jacks is necessary. If trouble is experienced with this equipment, for repair or warranty information, please contact: Manufacturer: Fire•Lite Alarms One Fire-Lite Place Northford, CT 06472 (203) 484-7161 Product Model Number: MS-5UD/MS-10UD FCC Registration Number: 1W6AL00B10UD Ringer Equivalence: 0.0B Important! The DACT must not be used to dial a phone number that is call-forwarded. This equipment complies with Part 68 of the FCC rules and the requirements adopted by the ACTA. On the inside of the FACP door is a label that contains, among other information, a product identifier in the format US:AAAEQ##TXXXX. If requested, this number must be provided to the telephone company. Alarm dialing equipment must be able to seize the telephone line and place a call in an emergency situation. It must be able to do this even if other equipment (telephone, answering system, computer modem, etc.) already has the telephone line in use. To do so, alarm dialing equipment must be connected to a properly installed RJ31X jack that is electrically in series with and ahead of all other equipment attached to the same telephone line. If there are any questions concerning these MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 23 Product Description Telephone Requirements and Warnings instructions, consult the telephone company or a qualified installer about installing the RJ31X jack and alarm dialing equipment. Refer to “Digital Communicator” on page 36 for an illustration of the proper installation of this equipment. 1.7.3 Telephone Company Rights and Warnings The telephone company, under certain circumstances, may temporarily discontinue services and/or make changes in its facilities, services, equipment or procedures which may affect the operation of this control panel. However, the telephone company is required to give advance notice of such changes or interruptions. If the control panel causes harm to the telephone network, the telephone company reserves the right to temporarily discontinue service. Advance notification will be provided except in cases when advance notice is not practical. In such cases, notification will be provided as soon as possible. The opportunity will be given to correct any problems and to file a complaint with the FCC if you believe it is necessary. DO NOT CONNECT THIS PRODUCT TO COIN TELEPHONE, GROUND START, OR PARTY LINE SERVICES. When the control panel activates, premise phones will be disconnected. Two separate phone lines are required. Do not connect both telephone interfaces to the same telephone line. The control panel must be connected to the public switched telephone network upstream (as first device) of any private telephone system at the protected premises. A plug and jack used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by ACTA. This equipment is designed to be connected to the telephone network or premises wiring using a compliant RJ31X male modular plug and compatible modular jack that is also compliant. 1.7.4 For Canadian Applications The following is excerpted from CP-01 Issue 5: NOTICE: The Industry Canada (IC) label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements document(s). The Department does not guarantee the equipment will operate to the users’s satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations. Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment. Users should ensure, for their own protection, that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas. CAUTION Users should not attempt to make such connections themselves, but should contact the appropriate electric inspections authority, or electrician. 24 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Telephone Requirements and Warnings Product Description “The Ringer Equivalence Number (REN) assigned to each terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone interface. the termination of an interface may consist of any combination of devices subject only to the requirement that the sum of the REN of all devices does not exceed 5.” DOC Compliance - “This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.” Representative: NOTIFIER/FIRE•LITE, CANADA 10 Whitmore Road Woodbridge, Ontario L4L7Z4 Phone: (905) 856-8733 FAX: (905) 856-9687 IC Certificate Number: 2132A-10UD Ringer Equivalence Number (REN): 0.0B Load Number: 2 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 25 Section 2: Installation The cabinet can be surface mounted or semi-flush mounted. The door is removable during the installation period by opening and lifting it off the hinges. The cabinet mounts using two key slots at the top of the backbox and two additional securing holes located at the bottom. Carefully unpack the system and check for shipping damage. Mount the cabinet in a clean, dry, vibration-free area where extreme temperatures are not encountered. The area should be readily accessible with sufficient room to easily install and maintain the panel. Locate the top of the cabinet approximately 5 feet (1.5 m) above the floor with the hinge mounting on the left. Determine the number of conductors required for the devices to be installed. Sufficient knockouts are provided for wiring convenience. Select the appropriate knockout(s) and pull the conductors into the box. All wiring should be in accordance with the National and/or Local codes for fire alarm systems. 2.1 Backbox Mounting ! CAUTION: STATIC SENSITIVE COMPONENTS THE CIRCUIT BOARD CONTAINS STATIC-SENSITIVE COMPONENTS. ALWAYS GROUND YOURSELF WITH A PROPER WRIST STRAP BEFORE HANDLING ANY BOARDS SO THAT STATIC CHARGES ARE REMOVED FROM THE BODY. USE STATIC SUPPRESSIVE PACKAGING TO PROTECT ELECTRONIC ASSEMBLIES. To prevent damage to the circuit board and to facilitate backbox mounting, the chassis with main circuit board and transformer can be easily removed. Loosen the two 3/8” nuts securing the top flanges of the chassis, then slide the chassis up to free it from the lower tabs. Place the chassis assembly in a protective antistatic bag in a safe location until it can be reinstalled in the backbox. Mark and predrill hole in the wall for the center top keyhole mounting bolt using the dimensions illustrated in Figure 2.2 on page 27. Install center top fastener in the wall with the screw head protruding. Place backbox over the top screw, level and secure. Mark and drill the left and right upper and lower mounting holes. Note: outer holes (closest to sidewall) are used for 16” O.C. stud mounting. Install remaining fasteners and tighten. MS-5UD Board on Chassis mounting holes mounting slots mounting tabs grounding stud: attach solid earth ground wire (refer to Figure 2.4 on page 29) mounting slots MS-5UD Backbox 5udbrdinbox.wmr mounting studs Figure 2.1 Chassis Mounting in Backbox 26 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Backbox Mounting Installation Semi-Flush Mounting Do not recess box more than 3.875” into wall to avoid covering venting holes on top of box. Hinge Slot for optional Dress Panel Mounting slots for optional Trim Ring SemiFlush mounting hole 9050UDencl.wmf Hinge Slot for optional Dress Panel Figure 2.2 Cabinet Dimensions MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 27 Installation Operating Power Top Depth = 5.207” (13.23 cm) Door = 16.821” (42.73 cm) Backbox = 16.65” (42.29 cm) Depth = 5.257” (13.353 cm) 9050UDcab2.wmf Door = 19.26” (48.92 cm) Backbox = 19.0” (48.26) Left Side Right Side Bottom Figure 2.3 Backbox and Battery Box 2.2 Operating Power ! WARNING: RISK OF ELECTRICAL SHOCK AND/OR EQUIPMENT DAMAGE SEVERAL DIFFERENT SOURCES OF POWER CAN BE CONNECTED TO THIS PANEL. DISCONNECT ALL SOURCES OF POWER BEFORE SERVICING. THE PANEL AND ASSOCIATED EQUIPMENT MAY BE DAMAGED BY REMOVING AND/OR INSERTING CARDS, MODULES OR INTERCONNECTING CABLES WHILE THIS UNIT IS ENERGIZED. Primary Power Source (AC) and Earth Ground Connections AC power connections are made inside the control panel cabinet. Refer to AC Power in the section titled “Specifications” on page 15, for power and current requirements for each FACP version. Run a pair of wires (with ground conductor) from the protected premises main breaker box to the AC terminal block TB1 on the main power supply. As per the National Electrical Code, use 14 AWG (2.00 mm2, 1.6 mm O.D.) or heavier gauge wire with 600V insulation. No other equipment 28 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Operating Power Installation may be connected to this circuit. In addition, this circuit must be provided with overcurrent protection and may not contain any power disconnect devices. An Earth Ground connection must be made to ensure proper panel operation and lightning and transient protection. Connect the Earth Ground wire [minimum 14 AWG (2.00 mm2)] to the grounding stud in the backbox and then run the wire to TB1. Do not use conduit for the Earth Ground connection since this does not provide reliable protection. Secondary Power Source (Batteries) Observe polarity when connecting the battery. Connect the battery cable to J12 on the main circuit board using the plug-in connector and cable provided. The battery charger is current-limited and capable of charging sealed lead acid batteries. The charger shuts off when the system is in alarm. ! WARNING: SULFURIC ACID BATTERIES CONTAINS SULFURIC ACID WHICH CAN CAUSE SEVERE BURNS TO THE SKIN AND EYES AND CAN DESTROY FABRICS. IF CONTACT IS MADE WITH SULFURIC ACID, IMMEDIATELY FLUSH THE SKIN OR EYES WITH WATER FOR 15 MINUTES AND SEEK IMMEDIATE MEDICAL ATTENTION. MS-5UDC-7(C)(E) MS-10UD-7(C)(E) MS-5UD-3(E) MS-10UD-3(E) FLPS-3 Power Supply FLPS-7 Power Supply AC Power AC Hot AC Neutral Earth 5ud_10udacpower.wmf AC Power Hot (L1) Earth Neutral (L2) - Ground Stud + - Ground Stud J12 + J12 to batteries to batteries Figure 2.4 Operating Power Connections MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 29 Installation Input Circuits 2.3 Input Circuits The MS-5UD has five IDCs (Initiating Device Circuits) and the MS-10UD has ten IDCs. Each circuit is compatible with System Sensor’s i3 smoke detectors which generate a maintenance signal when the detector becomes dirty and a separate supervisory ‘freeze’ signal when ambient temperature falls below the detector rating of approximately 45oF. The maximum loop resistance limit for each IDC is 100 ohms (700 ohms per zone for linear heat detection). Do not use 2-wire smoke detectors on input zones used for linear heat detection. The field wiring for each zone is supervised for opens, shorts and ground faults. All conditions are visually and audibly annunciated. Each circuit is configured for Style B (Class B) operation and will accept i3 smoke detectors, any normally-open contact devices as well as conventional 2-wire or 4-wire, 24 VDC smoke detectors. Refer to the Fire•Lite Device Compatibility Document for a list of compatible devices. Initiating Device Circuits can be converted to Style D (Class A) by installing the optional Class A Converter module. Refer to “CAC-5X Class A Converter Module” on page 37. Class B Initiating Device Circuits (supervised and power-limited) 4.7 K, ½ watt resistor P/N:71252 UL listed Power Supervision Relay (refer to Device Compatibility Document for list of compatible relays) UL listed compatible 4-wire smoke detector UL listed compatible 2-wire smoke detectors manual pull stations heat detectors Dummy load all unused circuits - 4.7 K, ½ watt resistor (P/N: 71245) ms-10UDidc.wmf Resettable 24 VDC 4-wire smoke detector power (500 mA maximum) Figure 2.5 IDC Connections 30 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Input Circuits Installation Combination Waterflow/Supervisory Zone A combination Waterflow/Supervisory circuit allows an FACP to distinguish between an Alarm switch (waterflow device) and a Supervisory switch (tamper) installed on the same circuit. Any circuit can be programmed as a Combo Type zone. The following figure illustrates the wiring of Zone 2 as a Style B (Class B) Waterflow/Supervisory circuit. Class B Initiating Device Circuits (supervised and power-limited) 4.7 K, ½ watt resistor P/N:71252 Supervisory Switch (tamper) In-Line-Resistor 1.2 K, ½ watt resistor P/N: 75579 Dummy load all unused circuits - 4.7 K, ½ watt resistor (P/N: 71245) ms10udcomboIDC.wmf Alarm Switch (waterflow) Figure 2.6 Style B Combination Circuit on Zone 2 Requirements for the Combination Waterflow/Supervisory circuit are as follows: The Waterflow Alarm Switch must connect to the FACP Initiating Device Circuit before the In-Line Resistor as shown in Figure 2.6 The Supervisory Switch must connect to the FACP Initiating Device Circuit after the In- Line Resistor as shown in Figure 2.6 Program the FACP Initiating Device Circuit as a Combination circuit as described in “Input Zones” on page 61. Note that since a Waterflow Supervisory Switch is included in a Combination circuit, the waterflow delay must be taken into consideration. Refer to “Waterflow Delay” on page 71. Waterflow Alarm Switch activation causes the panel to latch into alarm until the alarm condition is cleared and the FACP is reset Supervisory Switch activation causes the panel to latch the supervisory condition if the Combo type code is selected or track (the panel will clear when the supervisory condition is cleared) if the Combo Autoresettable Supervisory type code is selected MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 31 Installation Output Circuits 2.4 Output Circuits 2.4.1 Notification Appliance Circuits Total current drawn from the four Style Y (Class B) Notification Appliance Circuits as well as other DC power outputs cannot exceed 3.0 amps for the MS-5UD-3(E), MS-10UD-3(E) [2.5 amp maximum per NAC] powered by the FLPS-3 power supply or 7.0 amps for the MS-5UD-7(C/E), MS10UD-7(C/E) [3.0 amps maximum per NAC] powered by the FLPS-7 power supply (refer to “Power Supply Calculations” on page 116). Each circuit is supervised, power-limited and provides special application power. Refer to the Fire•Lite Device Compatibility Document for a listing of compatible notification appliances. The NACs can be converted to Style Z (Class A) by installing the optional Class A Converter module. Refer to “CAC-5X Class A Converter Module” on page 37. For FCC compliance with Class B wiring, a ferrite bead (supplied) is required for NAC 1 and for NAC 2. If using both NAC 1 and NAC 2 with Class B wiring, a single ferrite may be used with wiring as shown in Figure 2.7. Class B Notification Appliance Circuits (supervised and power-limited) 4.7 K, ½ watt resistor P/N:71252 Polarized Bell Polarized Bell Polarized Strobe Polarized Horn-Strobe Polarized Horn Polarized Horn Ferrite Bead p/n 50116546-001 Dummy load any unused circuits (P/N: 71245) + - + - ms-10UDnac.wmf Notification Appliance Circuit polarity shown in alarm condition Figure 2.7 NAC Connections 32 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Output Circuits Installation 2.4.2 Special Application DC Power Output Connections Special Application Resettable and Nonresettable 24 VDC power is available on the MS-5UD and MS-10UD control panel. Special Application Resettable or Nonresettable Power (500 mA) 24 VDC filtered, resettable or nonresettable power can be obtained from these terminals (power-limited) • Jumper JP31 pins 1 & 2 for nonresettable power (as illustrated in figure to right) • Jumper JP31 pins 2 & 3 for resettable power - 4 + 3 - 2 ms-10UDtb9.wmf Special Application 4-Wire Smoke Detector Power (500 mA) 24 VDC filtered, resettable power for 4-wire smoke detectors can be obtained from these terminals (power-limited) + 1 Figure 2.8 Special Application Auxiliary Power 2.4.3 Relays - Programmable The MS-5UD and MS-10UD control panels provide a factory default programmed alarm relay, failsafe trouble relay and supervisory relay. Each relay can be programmed to activate for other conditions (refer to “Relays” on page 69). Each Form-C relay is rated for 2 amps @ 30VDC (resistive) and 0.5 amps @ 30 VAC (resistive). ms10udrelay.wmf Note that relay connections must be power-limited. Note: Relay contacts are shown with power applied to the panel and no active troubles, alarms or supervisories. The Trouble Relay is a fail-safe relay which will transfer on any trouble or total power failure. Figure 2.9 Relay Terminals MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 33 Installation Output Circuits 2.4.4 Remote Synchronization Output Synchronization is a feature that controls the activation of notification appliances in such a way that all devices will turn on and off at exactly the same time. This is particularly critical when activating strobes which must be synchronized to avoid random activation and a potential hazard to individuals. Devices connected directly to the control panel’s NAC can be synchronized as described in “Synchronized NAC Operation” on page 68. Notification appliances connected to remote power sources may require synchronization with the FACP’s devices. For the MS-5UD-3(E), MS-10UD-3(E), this can be accomplished by connecting the Remote Synchronization Output from TB2 of the FACP to a compatible sync input of a power supply such as the FCPS-24FS6/8. The 24 VDC, 40 mA signal from TB2 follows, that is mimics the signal on NAC 1 (Out 1). This allows the devices connected to the power supply to be synchronized with the devices connected to Out 1 on the FACP. For the MS-5UD-7(C/E), MS-10UD-7(C/E), the Remote Sync Output is not required. Synchronization for remote power supplies is provided directly from NAC1 (Out 1). Note that NAC 1 (Out 1) must be programmed for sync operation when used for this purpose. The Remote Synchronization Output is power-limited and supervised and requires a 4.7K ELR resistor at the remote power supply end of the wiring. Remote Power Supply Sync Input 4.7K ELR FACP main circuit board 10xudsync.wmf Remote Sync Output Figure 2.10 Remote Sync Output 34 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Power-limited Wiring Requirements Installation 2.5 Power-limited Wiring Requirements Power-limited and nonpower-limited circuit wiring must remain separated in the cabinet. All power-limited circuit wiring must remain at least 0.25” (6.35 mm) away from any nonpower-limited circuit wiring. Furthermore, all power-limited and nonpower-limited circuit wiring must enter and exit the cabinet through different knockouts and/or conduits. A typical wiring diagram is illustrated below. Power-limited Circuits (Class 2) Power-limited Circuits (Class 2) Power-limited Circuits (Class 2) CAC-5X CAC-5X AC Power 4XTMF J13 Nonpowerlimited Circuit earth ground Nonpowerlimited Circuit MS-10UD FACP 10udULwire2.wmf Power-limited Circuit (Class 2) Figure 2.11 Typical UL Power-limited Wiring Requirements MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 35 Installation Digital Communicator 2.6 Digital Communicator Two independent telephone lines can be connected to the control panel. Telephone line control/command is made possible via double line seizure as well as usage of an RJ31X style interconnection. Note that it is critical that the panel's digital communicator be located as the first device on the incoming telephone circuit to properly function. Important! The DACT must not be used to dial a phone number that is call-forwarded. Customer Premises Equipment and Wiring Network Service Provider’s Facilities Computer RJ31X Jack Unused RJ-11 Jack FACP with DACT Telephone Line Telephone Fax Machine Telephone Unused J-11 Jack 9050ACTAdact.wmf Network Demarcation Point Answering System Telephone Figure 2.12 DACT Installation The control panel's digital communicator is built into the main circuit board. Connection and wiring of two phone lines is required as shown below. (Secondary Lines) Incoming Telco phone lines Ring Green Wire Red Wire Ring to premise phones Tip 1 2 3 4 5 6 7 8 Secondary phone line active LED Secondary phone line PH-2 J8 J9 Modular female connectors Ring to premise phones Tip 1 2 3 4 5 6 7 8 RJ31X Jack Primary phone line active LED (Primary Lines) Incoming Telco phone lines RJ31X Jack Note: Shorting bars inside RJ31X Jack removed during male plug insertion 7 foot cable MCBL-7 (ordered separately) Male plug connectors Primary phone line PH-1 10UDJACK2.wmf Tip Tip Green Wire Red Wire Ring Figure 2.13 Wiring Phone Jacks 36 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Installation of Optional Modules Installation 2.7 Installation of Optional Modules ! WARNING: RISK OF ELECTRICAL SHOCK REMOVE ALL POWER (AC AND DC) BEFORE INSTALLING OR REMOVING MODULES OR WIRING. 2.7.1 CAC-5X Class A Converter Module Installation The CAC-5X Module can be used to convert five Style B (Class B) Initiating Device Circuits to Style D (Class A) and the two Style Y (Class B) Notification Appliance Circuits to Style Z (Class A). The module plugs into connector J2 which is located at the top left of the MS-5UD and MS10UD main circuit board and J7 which is located at the top center of the MS-10UD. Note that two CAC-5X modules are required to convert all NACs and IDCs on the MS-10UD to Class A circuits. To install the CAC-5X in the MS-5UD or MS-10UD, remove the two main circuit board mounting screws referenced in the following illustration and replace with the two supplied male/female standoffs in the locations indicated in the following figure. Carefully align the connector on the CAC-5X with J2 on the FACP main circuit board and press the module securely into place. Make certain the pins are properly aligned to prevent bending or breaking of any connector pins. Secure the CAC-5X to the standoffs with the screws that were just removed. To install the second CAC-5X on J7 of the MS-10UD, remove the main circuit board mounting screw referenced in the following illustration and replace with the supplied male/female standoff. Insert the supplied plastic standoff in the location indicated in the following illustration. Carefully align the connector on the CAC-5X with J7 and press the module securely into place. Make certain the pins are properly aligned to prevent bending or breaking of any connector pins. Secure the CAC-5X to the metal standoff with the screw that was just removed. Installation in MS-10UD Installation in MS-5UD or MS-10UD CAC-5X Module CAC-5X Module Metal Standoff Plastic Standoff Metal Standoff ms-10udcac5mnt.wmf Metal Standoff MS-10UD Main Circuit Board Figure 2.14 CAC-5X Module Installation MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 37 Installation Installation of Optional Modules Wiring NACs and IDCs for Class A Wire the Style Z (Class A) Notification Appliance Circuits using TB5 of the MS-5UD/MS-10UD and TB2 of the CAC-5X module. Wire the Style D (Class A) Initiating Device Circuits using TB4 of the MS-5UD/MS-10UD and TB1 of the CAC-5X. Note that the wiring will be identical when using TB7 NAC and TB6 IDC of the MS-10UD. Make certain to observe polarity when connecting the devices to the circuits. The B+ and A+ terminals must comprise the feed and return for the positive side of a device and the B- and A- terminals must comprise the feed and return for the negative side of a device. To configure any of the zones for Class B when the CAC-5X is installed, simply wire to the B+ and B- input on the FACP terminal(s) and install the End-of-Line Resistor after the last device on the circuit. Do not wire to the corresponding A+ and A- terminals on the CAC-5X module. For FCC compliance with Class A wiring, a ferrite bead (supplied with the CAC-5X board) is required for NAC 1 and for NAC 2. If using NAC 1 and/or NAC 2 with Class A wiring, a ferrite must be used for each NAC with wiring as shown in Figure 2.15. Class B (Style B) IDC - 4.7 K ½ watt ELR resistor P/N:71252 (supervised and power-limited) Class A (Style D) IDC (supervised and power-limited) Smoke Smoke Pull Station Pull Station Class A (Style Z) NAC (supervised and power-limited) Polarized Bell Polarized Strobe Heat Heat Polarized Horn Ferrite Bead p/n 50116546-001 Circuit polarities shown in alarm condition B+ B- B+ B+ B- B+ B- B+ B- B+ B- B+ B- B- Dummy load all unused circuits - 4.7 K ½ watt resistor (P/N: 71245) MS-5UD Circuit Board A- A+ A- A+ A- A+ A- A+ A- A+ A- A+ A- ms10udclassa.wmf A+ CAC-5X Class A Converter Module Figure 2.15 Wiring NACs and IDCs for Class A Operation 38 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Installation of Optional Modules Installation 2.7.2 4XTMF Option Module The 4XTMF module can be plugged into connectors J4 and J5 on the main circuit board. The following steps must be followed when installing the 4XTMF module: 1. Remove all power (AC and DC) from the FACP before installing the modules. 2. Cut jumper JP30 on the main circuit board to allow the control panel to supervise the placement of the 4XTMF option module. 3. Install the two supplied metal standoffs in the locations indicated. These standoffs provide the required earth ground protection. 4. Carefully plug the connectors on the option module into connectors J4 and J5 on the FACP main circuit board, being careful not to bend any pins. 5. Secure the option module to the standoff on the main circuit board with the supplied screws. 6. For proper 4XTM operation, the output relays must be programmed for the factory default settings: Alarm Relay 1, Trouble Relay 2 and Supervisory Relay 3. 7. When the installation has been completed, connect the wiring to the modules as indicated in the following sections. 8. Test system for proper operation. J4 Standoffs J5 ms-5board.wmf SW1 Note: This illustration shows the installation of the Option Module on the 5-zone panel. The module is installed in the same location on the 10-zone panel. Figure 2.16 4XTMF Option Module Connection to MS-5UD 4XTMF Transmitter Module Installation The 4XTMF provides a supervised output for a local energy municipal box transmitter in addition to alarm and trouble reverse polarity. A jumper option allows the reverse polarity circuit to open with a system trouble condition if no alarm condition exists. A disable switch allows disabling of the transmitter output during testing to prevent accidental calling of the monitoring service. MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 39 Installation Installation of Optional Modules Local Energy Municipal Box Service (NFPA 72 Auxiliary Fire Alarm Systems): Supervisory Current: 5.0 mA Trip Current: 350 mA (subtracted from notification appliance power) Coil Voltage: 3.65 VDC Maximum Coil Resistance: 14.6 ohms Maximum allowable wire resistance between panel and trip coil: 3 ohms Municipal Box wiring can leave the building Remote Station Service (NFPA 72 Remote Station Fire Alarm Systems) - Intended for connection to a polarity reversal circuit or a Remote Station receiving unit having compatible ratings: Maximum load for each circuit: 10 mA Reverse polarity output voltage: 24 VDC Remote Alarm and Remote Trouble wiring can leave the building Before installing the module, place the disconnect switch to the down (disconnect) position to prevent accidental activation of the municipal box. Note that a Disconnect LED will illuminate after the module is installed in the FACP. In addition, the System Trouble LED will turn on to indicate the Disconnect condition. Note: the 4XTMF Module is not directly suitable for transmitting reverse polarity supervisory signal. For an application of reverse polarity of a supervisory signal, refer to the Appendix titled “FACP with Keltron” on page 131. Polarities are shown for module activation 1+ 23+ 45 6+ 7- Disconnect Switch shown in disconnect position No connection Municipal Box (nonpower-limited)* * Wiring from these terminals can exit the protected premises. Dummy load terminals 6 and 7 (4.7K, ¼ watt resistor) if Municipal Box is not connected. 4xtmf.wmf TBL Jumper Remote Alarm - Class 2 (power-limited)* Remote Trouble - Class 2 (power-limited)* Disconnect LED Connect to FACP Connectors J4 & J5 Figure 2.17 4XTMF Transmitter Module 2.7.3 ANN-SEC Option Card The ANN-SEC option card allows for a secondary ANN-BUS. Install the ANN-SEC as follows. 40 1. Remove the chassis mounting screw to the right of TB3 and replace it with the supplied 0.5” x 4-40 male-female standoff. 2. Install the header into J13 on the main circuit board. MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 ANN-BUS Devices Installation Secure the ANN-SEC to the circuit board with the supplied screw. ann-secinst.wmf 3. connector to J13 on main circuit board J1 ANN-SEC TB1 FACP Circuit Board standoff and screw Figure 2.18 Installing the ANN-SEC Option Card 2.8 ANN-BUS Devices ! WARNING: RISK OF ELECTRICAL SHOCK Disconnect all sources of power (AC and DC) before installing or removing any modules or wiring. Guidelines • A variety of optional annunciation devices can be connected to an ANN-BUS communication circuit. ANN Series devices can be connected to the primary communication circuit (EIA-485) terminals on TB3. A secondary communication circuit (EIA-485) for these devices is available at TB1 on the ANN-SEC card. • When using one ANN-BUS circuit, up to eight (8) annunciators can be supported. • When using both ANN-BUS communication circuits, the primary circuit supports up to three (3) annunciators and the secondary circuit supports up to (5) annunciators. Compatible devices include: – ANN-80 LCD Annunciator – ANN-80C LCD Indicator (Canadian Applications) – ANN-S/PG Serial/Parallel Printer Interface Module – ANN-I/O LED Driver Module – ANN-LED Annunciator Module – ANN-RLY Relay Module (can be mounted in the FACP chassis) • When operating two ANN-BUS circuits, only one ANN-S/PG Printer module can be used in the system. • The panel is capable of operating a primary ANN-BUS (TB3) and a secondary ANN-BUS (TB1 on ANN-SEC card) simultaneously. 2.8.1 ANN-BUS Wiring This section contains information on calculating ANN-BUS wire distances and the types of wiring configurations (Class B). The length of the 4-conductor wire run is governed by the power pair loading as described below. Calculating Wiring Distance for ANN-BUS Modules The following instructions will guide the installer in determining the type of wire and the maximum wiring distance that can be used with FACP ANN-BUS accessory modules. MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 41 Installation ANN-BUS Devices To calculate the wire gauge that must be used to connect ANN-BUS modules to the FACP, it is necessary to calculate the total worst case current draw for all modules on a single 4-conductor bus. The total worst case current draw is calculated by adding the individual worst case currents for each module. The individual worst case values are shown in the following table: Worst Case Current Draw1 Model Number ANN-80(C) LCD Annunciator/Indicator 0.040 amps ANN-S/PG Serial/Parallel Printer Interface Module 0.040 amps ANN-I/O LED Driver Module 0.200 amps ANN-LED Annunciator Module 0.068 amps ANN-RLY Relay Module 0.075 amps 1 Total worst case current draw on a single ANN-BUS cannot exceed 0.5 amp. After calculating the total worst case current draw, Table 2.1 specifies the maximum distance the modules can be located from the FACP on a single wire run. The table ensures 6.0 volts of line drop maximum. In general, the wire length is limited by resistance, but for heavier wire gauges, capacitance is the limiting factor. These cases are marked in the chart with an asterisk (*). Maximum length can never be more than 6,000 feet (1,800 m), regardless of gauge used. The formula used to generate this chart is shown in the note below. 24 VDC Power Wiring Distance: ANN-BUS Modules to FACP Total Worst Case Current Draw (amps) 22 Gauge 18 Gauge 16 Gauge 14 Gauge 0.100 1,852 ft. 4,688 ft. * 6,000 ft. * 6,000 ft. 0.200 926 ft. 2,344 ft. 3,731 ft. 5,906 ft. 0.300 617 ft. 1,563 ft. 2,488 ft. 3,937 ft. 0.400 463 ft. 1,172 ft. 1,866 ft. 2,953 ft. 0.500 370 ft. 938 ft. 1,493 ft. 2,362 ft. Table 2.1 Wiring Distances The following formulas were used to generate the wire distance chart: 6.0 Volts Maximum Resistance (Ohms) = Total Worst Case Current Draw (amps) Maximum Wire Length (feet) (6,000 feet maximum) Maximum Resistance (Ohms) = *500 Rpu where: Rpu = Ohms per 1,000 feet for various Wire Gauges (see table below) 42 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 ANN-BUS Devices Installation Wire Gauge Ohms per 1,000 feet (Rpu) 22 16.2 18 6.4 16 4.02 14 2.54 Exception: When using the ANN-RLY module, the installer must ensure that the maximum 24VDC power line drop does not exceed 0.3 volts. This results in the following wiring limitations: Wire Gauge Maximum Wire Length 18 312 feet 16 497 feet 14 787 feet 12 1,250 feet Wiring Distance Calculation Example: Suppose a system is configured with the following ANN-BUS modules: • 2 ANN-80 Remote Fire Annunciators • 1 ANN-S/PG Serial/Parallel Printer Interface Module • 1 ANN-I/O LED Driver Module The total worst case current is calculated as follows: ANN-80 Current Draw = 2 X 0.040 amps = 0.080 amps ANN-S/PG Current Draw = 1 X.0.040 amps = 0.040 amps ANN-I/O Current Draw = 1 X.0.200 amps = 0.200 amps Total Worst Case Current Draw = 0.320 amps Using this value and referring to the Wiring Distance Table 2.1 on page 42, it can be found that the available options are: 463 feet maximum using 22 Gauge wire 1,172 feet maximum using 18 Gauge wire 1,866 feet maximum using 16 Gauge wire 2,953 feet maximum using 14 Gauge wire MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 43 Installation ANN-BUS Devices Wiring Configuration Figure 2.19 illustrates the wiring between the FACP’s Primary ANN-BUS and ANN-BUS devices. FACP TB3 Primary ANN-BUS ann80to5x.wmf ANN-BUS and power wiring are supervised and power-limited ANN-80 Figure 2.19 FACP wiring to ANN-BUS Device on Primary ANN-BUS illustrates the wiring between the FACP’s Secondary ANN-BUS, via the ANN-SEC option card, and ANN-BUS devices. J1 ANN-SEC - + A B ann80to5x2.wmf TB1 FACP Secondary ANN-BUS ANN-BUS and power wiring are supervised and power-limited ANN-80 Figure 2.20 FACP wiring to ANN-BUS Device on Secondary ANN-BUS via ANN-SEC 44 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 ANN-BUS Devices Installation Powering ANN-BUS Devices from Auxiliary Power Supply Figure 2.21 illustrates the powering of ANN-BUS devices from an auxiliary power supply such as the FCPS-24FS6/8, when the maximum number of ANN-BUS devices exceeds the ANN-BUS power requirements. Cut Ground Fault Detection jumper JP1 (FACP monitors for ground faults) TB3 MS-5UD/MS-10UD ANN-BUS -24 VDC ANN-80 +24 VDC ann80tofcps5x.wmf ANN-BUS and power wiring are supervised and power-limited FCPS-24FS6/8 Figure 2.21 Powering ANN-BUS Devices from FCPS-24FS6/8 2.8.2 ANN-BUS Device Addressing Each ANN-BUS device requires a unique address (ID Number) in order to communicate with the FACP. A 5-position DIP switch on each device is used to set this address. The address set for these devices must also be programmed at the FACP for the specific device (refer to the programming section titled “ANN-BUS” on page 75). A maximum of 8 devices can be connected to the FACP ANN-BUS communication circuit. Device addresses do not need to be sequential and can be set to any number between 01 and 08. Note that 00 is not a valid address. The following table shows the DIP switch setting for each address. NOTE: address (ID Number) DIP switches on some devices may have more than 5 switch positions. Unless otherwise specified in the documentation supplied with each device, switch positions 6 and above must be set to OFF. Address Switch 5 Switch 4 Switch 3 Switch 2 Switch 1 not valid OFF OFF OFF OFF OFF 01 OFF OFF OFF OFF ON 02 OFF OFF OFF ON OFF 03 OFF OFF OFF ON ON MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 45 Installation ANN-BUS Devices 04 OFF OFF ON OFF OFF 05 OFF OFF ON OFF ON 06 OFF OFF ON ON OFF 07 OFF OFF ON ON ON 08 OFF ON OFF OFF OFF 2.8.3 ANN-80(C) Remote Fire Annunciator/Indicator The ANN-80(C) Annunciator/Indicator is a compact, 80 character, backlit LCD remote fire annunciator which mimics the FACP display. It also provides system status indicators for AC Power, Alarm, Trouble, Supervisory and Alarm Silenced conditions. The ANN-80 Annunciator provides buttons for remote Reset, Silence, Acknowledge, and Drill of the FACP. The ANN-80C Indicator does not provide these buttons. Communication between the ANN-80(C) and FACP is accomplished over a two wire serial interface employing the ANN-BUS communication format. The devices are powered, via two additional wires, from either the host FACP or remote UL-listed, filtered, power supply. Specifications • Operating Voltage Range: 18 VDC to 28 VDC • Current Consumption @ 24 VDC nominal (filtered and nonresettable): Normal/Standby (no activity): 37.0 mA Trouble: 39.0 mA Alarm: 40.0 mA AC Fail ( not backlit): 15.0 mA • For use indoors in a dry location Installation Ensure that all power (AC and DC) has been removed from the FACP before installing the annunciator. Opening/Closing Annunciator The following procedure details the steps used to open the annunciator in order to access the terminal block and DIP switches (refer to figure below): 1. Turn the key switch to the ON (Unlocked) position by turning the key counter-clockwise 2. Push in the snap latch located on the right side of the unit while pulling the cover open 3. To close the cover, make certain the key switch is in the ON (Unlocked) position. Swing the cover closed, snapping it shut 4. Turn the key switch to the OFF (Locked) position by turning clockwise and remove the key Key switch shown in ON position 46 Annunciator backplate Press in latch and Pull annunciator cover open ann-80_iso.wmf Annunciator cover with LCD display MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 ANN-BUS Devices Installation Mounting The ANN-80 can be surface or semi-flush mounted to a single, double or 4” square electrical box. Select and remove the appropriate knockout(s), pull the necessary wires through the knockouts and mount the annunciator in or on the wall depending on the type of installation desired. The ANN-SB80KIT(-R/-B/-W) is an available mounting kit for the ANN-80 annunciator. The kit comes with a surface backbox and surface wedge for angled viewing. The two pieces can be used separately or can be stacked together. ann80kitmount.wmf The ANN-80 cover must be attached to the annunciator backplate before mounting the annunciator to the electrical box/wall. The cover cannot be reattached or removed after the annunciator has been mounted. Annunciator mounted on surface wedge from the ANN-SB80KIT Annunciator mounted on surface backbox from the ANN-SB80KIT Annunciator mounted on stacked surface wedge and backbox from the ANN-SB80KIT Wiring ANN-80 to FACP The following steps can be used as a guide to wire the annunciator. Make certain all power has been removed from the FACP prior to annunciator installation. Route wires from hole in backplate, through wiring channel and then to ANN-80 terminal block TB1. ann-80boxinside.wmf 1. wiring channel wires TB1 2. Remove appropriate amount of wire insulation. 3. Connect the wiring from the FACP ANN-BUS to annunciator TB1 terminals 3 (A) & 4 (B). Make certain to connect A to A and B to B. 4. If appropriate, connect the wiring going to the next device on the ANN-BUS to TB1 terminals 3 & 4. Make certain to connect A to A and B to B. MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 47 Installation ANN-BUS Devices 5. Connect the wiring from the 24 VDC power source to annunciator TB1 terminals 1 (-) & 2 (+). Make certain to observe proper polarity. 6. If appropriate, connect the power wiring going to the next device to terminals 1 (-) & 2 (+). Make certain to observe proper polarity. 7. After all connections are made, remove extra wire from inside of annunciator by dressing it neatly through wire channel, with any excess wire pushed back through hole into electrical box. FACP TB3 Primary ANN-BUS 4 3 2 1 ann80to5x.wmf ANN-BUS and power wiring are supervised and power-limited ANN-80 Figure 2.22 ANN-80 Wiring to FACP The following table shows the ANN-80 connections to the MS-5UD/MS-10UD. MS-5UD/MS-10UD (TB3) ANN-80 (TB1) Terminal 4 GND (-) Terminal 1 (-) Terminal 3 PWR (+) Terminal 2 (+) Terminal 2 A (ANN-BUS) Terminal 3 (A) Terminal 1 B (ANN-BUS) Terminal 4 (B) Programming Following installation and wiring of the ANN-80 LCD annunciator to the FACP, the annunciator must be added to the system via FACP programming. Refer to the programming section titled “ANN-BUS” on page 75 in this manual for detailed programming information. Select the LCD option for programming. 2.8.4 ANN-S/PG Serial/Parallel Printer Interface Installation The ANN-S/PG Serial/Parallel Printer Interface module allows the ancillary connection of a serial or parallel printer to the FACP for a real-time log of system events, detector status reports and event history. Proceed with the installation as described in the following: 1. 48 Ensure that all power (AC and DC) has been removed from the FACP. MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 ANN-BUS Devices Installation Connect the ANN-S/PG to the FACP as illustrated in Figure 2.23. annspfto5x.wmf 2. TB3 Primary ANN-BUS Primary ANN-BUS ANN-S/PG Module ANN-BUS and power wiring are supervised and power-limited Parallel Cable Connectors for connection to printer Serial Figure 2.23 ANN-S/PG Connection to FACP 3. Using the DIP switches on the back of the ANN-S/PG module, assign an ID number (address) to the module. 4. Select the address and configuration options for the ANN-S/PG module as described in the Programming section of this manual (refer to“ANN-BUS” on page 75). Note that the Auto-configure feature allows the programmer to quickly bring all installed ANN-BUS modules online (refer to“Auto-Configure” on page 76). 5. Connect a printer to the ANN-S/PG Parallel and/or Serial connectors (refer to Figure 2.23 on page 49). Specifications • Operating Voltage: 24 VDC • Current (Alarm and Standby): 45 mA • Ambient Temperature: 32oF to 120oF (0oC to 49oC) • Max. Wiring Distance from FACP: 6,000 ft. (1,800 m) • Mounting: Surface • Dimensions: 6”W x 7-3/4”H x 1-7/16”D (15.2 cm W x 19.7 cm H x 3.7 cm D) • For indoor use in a dry location only PRN-6F Printer Installation When connected to the FACP via the ANN-S/PG module, the PRN-6F prints the status changes within the control panel and time-stamps the printout with the time of day and date that the event occurred. It provides 80 columns of data on standard 9” x 11” tractor-feed paper. This section contains information on connecting a printer to the control panel and setting the printer options. Connecting PRN-6F Printer Remote printers require a primary AC power source. If required for the fire alarm system configuration (for example, a Proprietary Fire Alarm System), a remote printer requires a secondary power source (battery backup). Since a secondary power source is not provided as a standard feature, a separate UL-listed Uninterruptible Power Supply (UPS) should be used. The building emergency power supply may be used, as long as it meets the power continuity requirements of NFPA 72. Refer to NFPA 72 for further details. Connect the remote printer to the FACP via the ANN-S/PG module using a standard DB-25 cable. One end of the cable will plug into the DB-25 connector on the PRN-6F printer and the other end plugs into the parallel connector on the ANN-S/PG module. Note that the 9-pin DB-9 port on the ANN-S/PG is used to connect a serial printer. The 25-pin port is used for a Centronics parallel printer cable. Connect either a serial or parallel printer, but not both at the same time. MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 49 Installation ANN-BUS Devices Setting Printer Options Refer to the documentation supplied with the PRN-6F printer for instructions on using the printer menu controls. Set the printer options (under the menu area) as shown in the following table: Option Setting Option Setting Font HS Draft CPI 10CPI LPI 6 LPI Skip 0.5 ESC Character ESC Emulate Epson FX-850 Bidirectional Copy ON I/O CG-TAB Graphic Country E-US ASCII Auto CR OFF Baud 9600 or 2400 Color Option Not Installed Format 7 Bit, Even, 1 Stop Protocol XON/XOFF Buffer Formien 40K Serial Lines 6LPI=60 Character Set Standard Standard Exec 10.5 SI.Zero On Auto LF On PAPER BIN 1 12/72” BIN 2 12/72” SINGLE 12/72” PUSH TRA 12/72” PULL TRA 12/72” PAP ROLL 12/72” Table 2.2 PRN-6F Setup Options 50 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 ANN-BUS Devices Installation 2.8.5 ANN-I/O LED Driver Module The ANN-I/O is an LED driver module that can be used in a wide variety of applications, including as an interface with most customized graphic annunciators. The ANN-I/O can drive up to 40 LEDs. The following sections describe hardware installation. Refer to the section titled“ANNBUS” on page 75 for programming information. ANN-I/O Board Layout Figure 2.24 illustrates the ANN-I/O board showing locations of screw terminals for connection to the FACP, pin connectors for connecting LEDs and the DIP switch for selecting the ANN-BUS ID number. anniobrd.wmf Terminals not used (future) ANN-BUS (ID#) Address DIP switch ANN-BUS Connector Figure 2.24 ANN-I/O Board Layout Specifications • Max. ANN-BUS Voltage: 28 VDC • Max. Current: Alarm: 200 mA Standby: 35 mA Each LED: 10 mA • Operating Temperature: 32oF to 120oF (0oC to 49oC) • For indoor use in a dry location only MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 51 Installation ANN-BUS Devices ANN-I/O Connection to FACP ann-ioto5x.wmf The ANN-I/O connects to the FACP via the ANN-BUS as illustrated in Figure 2.25. After the ANN-I/O is connected to the panel, it must be added to the system via FACP programming. TB3 Primary ANN-BUS ANN-I/O Module ANN-BUS and power wiring are supervised and power-limited Figure 2.25 ANN-I/O Connection to FACP ANN-I/O Module LED Wiring There are four 12-pin connectors on the ANN-I/O module for connecting LEDs. Each set of 10 LEDs get their power from Pin 11 of the corresponding connector. Internal resistors are sized so that there is approximately 10 mA of current for each LED. No series resistors are required. LED outputs are mapped to output circuits. Refer to the section titled “ANN-I/O LED Zone Assignments” on page 77 of this manual. 52 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 ANN-BUS Devices Installation ann-ioleds.wmf The LEDs are wired as illustrated in Figure 2.26. Note that the illustration depicts only connectors P1 and P2. Wiring is identical for P3 (LEDs 21-30) and P4 (LEDs 31-40). Figure 2.26 ANN-I/O Board Layout 2.8.6 ANN-LED Annunciator Module The ANN-LED annunciator module provides LED annunciation of general system faults and input zones when used with a compatible FACP. The ANN-LED module provides alarm (red), trouble (yellow) and supervisory (yellow) indication for up to ten input zones. Canadian Applications: The ANN-LED is supplied standard with the MS-5UD-7C and MS-10UD7C models. It is mounted to the dress panel included with these models. Specifications • Max. ANN-BUS Voltage: 24 VDC • Max. Current: Alarm: 68 mA Standby: 28 mA • Operating Temperature: 32o F to 120o F (0o C to 49o C) • For indoor use in a dry location only MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 53 Installation ANN-BUS Devices Mounting/Installation Install the ANN-LED Module as described in the documentation supplied with the annunciator. ANN-LED Board Layout and Connection to FACP Figure 2.27 illustrates the ANN-LED board wiring connections to the FACP. annledto5x.wmf ANN-BUS (ID#) Address DIP switch TB3 ANN-LED FACP -24 VDC +24 VDC Primary ANN-BUS Figure 2.27 ANN-LED Board Layout and Connection to FACP 2.8.7 ANN-RLY Relay Module The ANN-RLY relay module provides 10 programmable Form-C relays when used with a compatible FACP. Specifications • Operating Voltage: 24 VDC • Max. Current: Alarm: 75 mA Standby: 15 mA • Relay Contact Ratings: 2 amps @ 30 VDC (resistive) 0.5 amps @ 30 VAC (resistive) 54 • Operating Temperature: 32o F to 120o F (0o C to 49o C) • For indoor use in a dry location only MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 ANN-BUS Devices Installation Mounting/Installation FACP Chassis Installation mounting holes ann-rlyinchassis.wmf The ANN-RLY relay module can be mounted inside the FACP main circuit board chassis or inside the ROME Series enclosure. Refer to the ANN-RLY Installation Document #53033 for instructions on chassis mounting or to the ROME Series Installation Document #53530 for mounting in the separate backbox. FACP Backbox Installation using ANN-MBRLY mounting bracket grounding wire mounting holes ANN-MBRLY mounting bracket ann_mbriyincab3.wmf mounting hooks through mounting slots ANN-RLY mounting holes mounting holes rome-relay-plate3.wmf ROME Series Installation using ANN-MBRLY mounting bracket ANN-RLY on ANNmounting holes MBRLY mounting bracket Figure 2.28 ANN-RLY Mounting Options MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 55 Installation ANN-BUS Audio Panel ANN-RLY Board Layout and Connection to FACP Figure 2.29 illustrates the ANN-RLY board wiring connections to the FACP. ann-rlyto5x.wmf ANN-BUS (ID#) Address DIP switch TB3 ANN-RLY FACP -24 VDC +24 VDC Primary ANN-BUS Figure 2.29 ANN-RLY Board Layout and Connection to FACP 2.9 ANN-BUS Audio Panel ! WARNING: RISK OF ELECTRICAL SHOCK DISCONNECT ALL SOURCES OF POWER (AC AND DC) BEFORE INSTALLING OR REMOVING ANY WIRING. The FACP must be enabled to communicate with the ACC-25/50ZS/T Audio Panel over the ANNBUS (refer to “ANN-BUS Enabled” on page 75). This is accomplished by programming the Audio Panel ANN-BUS address into the FACP (refer to“BUS Modules” on page 75). For details on setting the ANN-BUS address and programming the audio panel, refer to the ACC-25/50ZS/T Series Audio Panel manual (document #51889). The ACC-25/50ZS/T Series audio panel connects to the FACP via the ANN-BUS communication circuit. The five input zones on the MS-5UD correspond to the first five ACC-25/50ZS/T Series audio zones and the ten input zones on the MS-10UD correspond to the first ten ACC-25/50ZS/T Series audio zones. The programmer can select which of the five audio messages at the audio panel will play when an FACP input zone goes into alarm (refer to“ACC Message” on page 64). The 56 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 ANN-BUS Audio Panel Installation message will play over the corresponding audio panel output circuit. For example, if FACP Input Zone 3 goes into alarm, the programmed message will play over the ACC-25/50ZS/T output circuit 3. If two or more input zones are active at the same time, the highest priority message will turn on. One of the FACP input zones can be programmed as an All-Call Zone. If this zone goes into alarm, all ACC-25/50ZS/T Series audio zones will activate (refer to“ANN-AUDIO Options Screen” on page 79). A fault at the ACC-25/50ZS/T Series panel will cause the FACP to indicate a System Trouble and the display will indicate a Voice Evac Fault. The only connection between the MS-5UD/10UD and the ACC-25/50ZS/T audio panel is a pair of communication wires connected between the A/B terminals on TB3 of the FACP and TB1 terminals 2 & 3 of the ACC-ZPMK module on the ACC-25/50ZS/T. FACP A (+) Primary ANN-BUS - acczpmto5x.wmf + B (-) ACC-ZPMK on ACC-25/50ZST Figure 2.30 FACP Connection to ACC-25/50ZS/T Audio Panel MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 57 Section 3: Programming NOTICE TO USERS, INSTALLERS, AUTHORITIES HAVING JURISDICTION, AND OTHER INVOLVED PARTIES This product incorporates field-programmable software. In order for the product to comply with the requirements in the Standard for Control Units and Accessories for Fire Alarm Systems, UL 864, certain programming features or options must be limited to specific values or not used at all as indicated below: Program feature or option Permitted in UL 864? (Y/N) Trouble Call Limit N Refer to “Trouble Call Limit (Dialer Runaway Prevention)” on page 89. Trouble Call Limit = 0 (factory default): unlimited calling to Central Station for any trouble condition Trouble Call Limit = 1 - 99: limits call for each unique trouble to from 1 to 99 within a 24 hour period Trouble Call Limit = 0 for unlimited Central Station trouble calls Remote Download Y Refer to“Remote Download” on page 113. Remote Download - Proprietary No Remote Download - Proprietary Yes Remote Download Proprietary Yes for Proprietary system intended to protect only contiguous properties Combo Y Refer to Table 3.1 on page 62. One Waterflow and one Supervisory device Combo w/AutoResettable Superv Y Refer to Table 3.1 on page 62. One Waterflow and one Supervisory device Possible settings Settings permitted in UL 864 3.1 User Programming The MS-5UD/MS-10UD FACP is completely field programmable using the panel keypad and requires no special software skills. ! CAUTION: FIRE PROTECTION ENABLED WHILE PROGRAMMING THE FACP, THE FIRE PROTECTION CAPABILITIES OF THE CONTROL PANEL ARE ENABLED. PROGRAMMING MODE TIMES-OUT AFTER 10 MINUTES OF INACTIVITY. Site-specific programming may be accomplished in the following ways: • Manual programming or editing, using the FACP keypad • Remote Programming and Editing Feature - allows creation and editing of site-specific custom programs using a Windows-based computer and modem. For programs requiring a large amount of data entry, this method may be preferred. A PK-CD programming CD ROM can be ordered for this purpose • Local Programming and Editing Feature - allows creation and editing of site-specific custom programs using a Windows-based computer and USB connection. For programs requiring a large amount of data entry, this method may be preferred. A PK-CD programming CD ROM can be ordered for this purpose The System All Normal screen will be displayed in a programmed system with no active alarms, troubles or supervisories, as illustrated below: SYSTEM ALL NORMAL 10:00A 070707 58 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Initial Power-up Programming Read Status mode can be entered while the panel is in any mode of operation. If an alarm or supervisory event exists at the panel, the event must be cleared before entering Programming mode. To access any of the programming or read status features, the Enter or Mode key must be pressed, which will cause the LCD to display the following: 1=READ STATUS MODE 2=PROGRAMMING MODE 3=FUTURE USE 4=REMOTE DOWNLOAD Pressing 1, while this screen is being displayed, will cause the control panel to enter the Read Status Mode which allows the user to view the programmed features and status of the control panel The Read Status feature is not password protected. Refer to “Read Status” on page 105 for a detailed description of this feature. Pressing 2 will select user Programming Mode which may only be accomplished by an authorized person. After pressing 2, a screen will prompt for a password. After entering the correct password, the user may select from a list of programming options. Pressing 4 will select Remote Download which allows the user to enable the remote programming option. Refer to “Remote Download” on page 113. Exit Programming and Read Status Mode The programmer can exit any mode by repeatedly pressing the keypad ESC (Escape) key until the display reads System All Normal. Ten minutes of inactivity will also cause the panel to exit Programming Mode Note that the data which is entered during Programming mode is not saved until the programmer exits this mode by repeatedly pressing the ‘ESC’ key. If the Reset key is pressed or power is lost before exiting Programming mode, all data just entered will be lost. User Programming Levels There are two user programming levels: • User Master Program Level 1 is used for programming panel specific data relating to device types, zoning, messages, control panel functions, etc. • User Maintenance Program Level 2 is used by a qualified operator to access features such as Disable/Enable, View and Clear History, Walktest and System Time Change. 3.2 Initial Power-up The following sections describe the initial programming procedures for a new system. The same procedures are used to modify programming in an existing system. After completing the wiring of devices to the FACP, apply power to the control panel. If wiring has not been completed and/or End-of-Line resistors are not installed at the panel, a trouble condition will be indicated at the panel and a trouble message will be displayed on the LCD. Following is an example of a possible trouble message that may be displayed. TROUBLE PULL STATION ZONE 1 OPEN FAULT 09:03A 090909 3.3 Programming Screens Description Three options are available when the Enter key is pressed: Read Status, Programming, and Remote Download Mode. The Read Status and Programming options have multiple functions or features which may be chosen. To view all of the choices, it is necessary that the programmer scroll through MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 59 Programming Programming and Passwords a number of additional subscreens. These selections are displayed on multiple screens to make them more readable for the programmer. Refer to “Master Programming Level” on page 61, for additional information on the various screens. The title of the main option screen will always be displayed at the top of the subscreens for the programmer’s convenience. If additional subscreens exist, an Up or Down arrow will be displayed in the upper right corner of the screen being viewed. The programmer can then press the keypad Up or Down arrow key to view the new subscreen. To select one of the choices in a screen, the programmer presses the keypad numerical key corresponding to the desired choice. Note that subscreens may also have multiple options which require viewing more than one screen. The same process, as detailed in the previous paragraphs, is followed to view all option choices. 3.4 Programming and Passwords There are two factory set programming passwords which will access the Programming screens as indicated in the following examples. From either of the screens, access to specific system and device features or programming may be obtained. All user programming entries are stored in nonvolatile memory. The factory set passwords can be changed by the user as described in “Password Change” on page 92. If an invalid password is entered, the blinking cursor will return to the first password character position. To exit Programming or Read Status mode at any time, press the ESC (Escape) key repeatedly. Note that Programming mode must be exited using the ESC key in order to store the program data entered during this mode. If the Reset key is pressed or power is lost before exiting Programming mode, the data just entered will not be saved. To access user Programming mode, press the Enter or Mode key. The LCD will display the following: 1=READ STATUS MODE 2=PROGRAMMING MODE 3=FUTURE USE 4=REMOTE DOWNLOAD To enter the user Programming mode, press 2. The display will read as follows: PROGRAMMING ENTER PASSWORD Entering the Master level password (default 00000) will cause the following screen to appear: PROGRAMMING 1=INPUT ZONES 2=NACS 3=RELAYS If the Maintenance level password (default 11111) is entered, the following screen will appear: PROGRAMMING 1=INPUT ZONES 2=HISTORY 3=WALKTEST Note that in the two preceding screens, an arrow appears to inform the programmer that additional options can be viewed by pressing the keypad down arrow key. 60 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Master Programming Level Programming 3.5 Master Programming Level When the Master Program Level password is entered, the control panel will enter user Programming mode. In this mode, the piezo sounder remains off, the trouble relay is activated and the system Trouble LED flashes until Programming mode is exited. The following display will appear: PROGRAMMING 1=INPUT ZONES 2=NACS 3=RELAYS Programming Screen #1 The down arrow which appears in the display indicates that additional programming choices can be viewed by pressing the down arrow key on the keypad. If a down and up arrow appear in the display, pressing the ‘down’ arrow key will display the subsequent Programming Screens as illustrated below while pressing the ‘up’ arrow key will display the previous screen. PROGRAMMING 1=SYSTEM SETUP 2=OPTION MODULES 3=HISTORY PROGRAMMING 1=WALKTEST 2=CLEAR PROGRAM 3=PASSWORD CHANGE Programming Screen #2 Programming Screen #3 3.5.1 Input Zones PROGRAMMING 1=INPUT ZONES 2=NACS 3=RELAYS The Input Zones option allows the user to initially program or change the programming for the five input zones (circuits) on the MS-5UD or the ten input zones (circuits) on the MS-10UD. Pressing 1, while viewing Programming Screen #1, will select the Input Zones option and display a screen Programming Screen #1 similar to the following: INPUT ZONES 1=ZONE 1 2=ZONE 2 3=ZONE 3 Input Zone Screen #1 Pressing the down arrow key will display additional screens for Input Zones 4 through 5 in the MS5UD or Input Zones 4 through 10 in the MS-10UD. To program a specific zone, press the number key corresponding to the desired zone while viewing one of the Input Zone screens. To program Input Zone 1, press the 1 key while viewing Input Zone Screen #1. The following screens will be displayed: PULL STATION ZONE 1 PRESS TO EDIT Edit Input Zone Screen #1 To change the programming for the displayed zone, press the keyboard ‘down’ arrow key to view the Edit Zone screens. MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 61 Programming Master Programming Level The following examples show the editing of Input Zone 1: INPUT ZONE 1 1=PAS/PRE-SIG DELAY NO DELAY INPUT ZONE 1 1=ENABLED YES 2=TYPE PULL STATION 3=VERIFICATION NO Edit Input Zone Screen #3 Edit Input Zone Screen #2 INPUT ZONE 1 1=ADJECTIVE/NOUN 2=DESCRIPTION INPUT ZONE 1 1=FREEZE SUPV. NO 2=ACC MSG# 2 Edit Input Zone Screen #4 INPUT ZONE 1=ENABLED 2=TYPE 3=VERIFICATION Edit Input Zone Screen #5 Enable/Disable Zone To Enable or Disable the zone, press the 1 key while viewing the Edit Input Zone Screen #2. Each press of the key will toggle the screen between Enabled Yes and Enabled No. If Enabled No is Edit Input Zone Screen #2 selected, the zone will be disabled by the control panel, preventing the circuit from reporting alarms and troubles to the panel. The control panel LCD will display the zone which has been disabled and FACP will turn on the Trouble LED. Type To select the type of zone being programmed, press the 2 key while viewing the Edit Input Zone Screen #2. This will cause the control panel to display the following Zone Type Screen: ZONE TYPE 1=PULL STATION 2=WATERFLOW 3=WATERFLOW NS Zone Type Screen #1 Pressing the down arrow key will display additional zone types as indicated in the following table. Some of the following Zone Types are not available for Canadian applications. Refer to “Canadian Option” on page 74 for additional details. Zone Type Action When Activated Pull-Station Fire Alarm Waterflow Fire Alarm Delayed (uses waterflow delay) Waterflow Nonsilenceable Fire Alarm (uses waterflow delay) Combo Fire/Supervisory (uses waterflow delay) Combo AutoResettable Fire/Supervisory AR, nonlatching (uses waterflow delay) 2-Wire Detector Fire Alarm Normally Open Contact Fire Alarm Fire Fire Alarm Tamper Supervisory Supervisory Supervisory, latching Supervisory AutoResettable Supervisory, nonlatching Medic-Alert Supervisory, latching Hazard-Alert Supervisory, latching Tornado-Alert Supervisory, latching Table 3.1 Zone Types 62 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Master Programming Level Programming Proc-Mon Piezo Procmon-AR Piezo, nonlatching AC-Loss-Mon Trouble Ack-Switch Acts like panel Acknowledge Key Sil-Switch Acts like panel Alarm Silence Key Drill-Switch Acts like panel Drill Key Reset-Switch Acts like panel Reset Key PAS-Bypass Positive Alarm Sequence Disable Drill-Switch AutoResettable Acts like panel Drill Key, nonlatching Table 3.1 Zone Types While viewing any Zone Type screen, select the type of zone being programmed by pressing the corresponding keyboard number key. The display will return to Edit Input Zone Screen #2 and indicate the selection next to the Type option. NOTE: Almost any Input Zone type can activate an ACC-25/50ZST audio zone and output an assigned message with the exception of ACKNOWLEDGE, SILENCE, RESET and PAS BYPASS Switches. The DRILL Switch (or input programmed as a drill switch) will cause all of the corresponding ACC-25/50ZST audio zones to go active and will output Message 1. INPUT ZONE 1=ENABLED 2=TYPE 3=VERIFICATION Edit Input Zone Screen #2 Verification Alarm verification is used to confirm that a smoke detector activation is a true alarm condition and not a false alarm. This feature is selected by pressing 3 while viewing the Edit Zone Screen #2 so that the display reads Verification On. Each time the 3 key is pressed, the display will toggle between Verification On and Verification Off. For a detailed description, refer to “Alarm Verification (None or One Minute)” on page 104. Note that verification can only be enabled for a zone that is programmed as a smoke detector type. Zones programmed for any other type will not allow the Verification feature to be enabled. Do not use the verification feature if a mix of smoke detectors and normally open contact devices are connected to the same zone. INPUT ZONE # 1=PAS/PRE-SIG DELAY NO DELAY PAS/Pre-Signal Delay Pressing 1 while viewing Edit Input Zone Screen #3 will display the following screen: Edit Input Zone Screen #3 PAS/PRE-SIG DELAY 1=NO DELAY 2=PRE-SIGNAL DELAY 3=PAS DELAY PAS/Pre-Signal Delay Screen Pre-signal The Pre-signal option programs the zone to delay panel activation for a preprogrammed time delay of up to three minutes while allowing for visual verification by a person. Note that the alarm relay and communicator will respond to the initial alarm immediately. To enable the Pre-signal feature, press 2 while viewing PAS/Pre-Signal Screen. Refer to “Presignal” on page 102. PAS The PAS (Positive Alarm Sequence) option will program the zone to delay panel activation (including alarm relay and communicator) for a period of 15 seconds plus a programmable time of up to 3 minutes. To enable the PAS feature, press 3 while viewing the PAS/Pre-Signal Screen. This option is available only for circuits programmed as smoke detector circuits. Refer to “Positive Alarm MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 63 Programming Master Programming Level Sequence” on page 103. Freeze Supervision INPUT ZONE # 1=FREEZE SUPV. 2=ACC MSG # NO Edit Input Zone Screen #4 Pressing 1 for Freeze Supv. while viewing Edit Input Zone Screen #4 programs the FACP to supervise the devices connected to the selected zone for freeze conditions. Each press of the 1 key will toggle the display between Freeze Supv. Yes and No. The factory default setting is No Freeze Supervision. ACC Message Pressing 2 for ACC MSG # while viewing Edit Input Zone Screen #4 will cause the following screens to be displayed: ACC MSG NUMBER 1=NO MSG-ACTIVE 2=NO MSG-INACTIVE 3=MESSAGE 1 ACC Message Screen #1 ACC MSG NUMBER 1=MESSAGE 2 2=MESSAGE 3 3=MESSAGE 4 ACC Message Screen #2 ACC MSG NUMBER 1=MESSAGE 5 ACC Message Screen #3 Using these screens, the programmer can assign an audio message to each input zone. The NO MSG-ACTIVE option is the factory default selection which means that no message has been programmed for the input zone but its corresponding ACC-25/50ZST audio zone will turn on when this input zone goes active (if an input zone with a programmed audio message goes active, the message will also be played over this zone). The NO MSG-INACTIVE option will not turn on the corresponding ACC-25/50ZST audio zone when this input goes active. If MESSAGE 1 through 5 is the programmed option, the selected message will play when the FACP is connected to an ACC25/50ZST Audio Panel via the ANN-BUS and the corresponding FACP input zone goes into alarm. INPUT ZONE # 1=ADJECTIVE/NOUN 2=DESCRIPTION Adjective/Noun The Adjective/Noun selection allows the programmer to enter specific descriptors about the detecEdit Input Zone Screen #5 tor currently being programmed. Pressing 1 while viewing Edit Input Zone Screen #4 will cause the following screen to be displayed: 1=STANDARD ADJECTIVE 2=STANDARD NOUN 3=CUSTOM ADJECTIVE 4=CUSTOM NOUN Adjective/Noun Screen Pressing 1 while viewing the Adjective/Noun Screen will cause the following screen(s) to be displayed. Note that the keyboard down arrow key must be pressed to see all the Adjective screens. Press the number corresponding to the adjective that is to be used as a descriptor for the location of the detector currently being programmed. When an adjective has been selected, it will appear at the top of the display as indicated by the asterisks. 1=NORTH 2=SOUTH 3=EAST Adjective Screen #1 1=MAIN 2=FIRST 3=2ND Adjective Screen #4 1=WEST 2=FRONT 3=CENTER Adjective Screen #2 1=3RD 2=4TH 3=5TH Adjective Screen #5 1=REAR 2=UPPER 3=LOWER Adjective Screen #3 1=FLOOR1 2=FLOOR2 3=FLOOR3 Adjective Screen #6 1=FLOOR4 2=FLOOR5 3=ROOM Adjective Screen #7 64 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Master Programming Level 1=STANDARD ADJECTIVE 2=STANDARD NOUN 3=CUSTOM ADJECTIVE 4=CUSTOM NOUN Adjective/Noun Screen Programming Pressing 2 while viewing the Adjective/Noun Screen will cause the following screen(s) to be displayed. Note that the keyboard down arrow key must be pressed to see all the Noun screens. Press the number corresponding to the noun that is to be used as a descriptor for the location of the detector currently being programmed. When a noun has been selected, it will appear at the top of the display as indicated by the asterisks. 1=BASEMENT 2=BOILER RM 3=CLASSROOM 1=CLOSET 2=CORRIDOR 3=ELECTRIC RM Noun Screen #4 1=STAIRWAY 2=STOREROOM 3=WING Noun Screen #7 1=STANDARD ADJECTIVE 2=STANDARD NOUN 3=CUSTOM ADJECTIVE 4=CUSTOM NOUN Adjective/Noun Screen INPUT ZONE # 1=ADJECTIVE/NOUN 2=DESCRIPTION Noun Screen #3 Noun Screen #2 Noun Screen #1 1=GARAGE 2=HALLWAY 3=HVAC RM 1=ELEVATOR 2=ENTRANCE 3=FLOOR 1=KITCHEN 2=LOBBY 3=OFFICE 1=PATIENT 2=RESTROOM 3=ROOM Noun Screen #5 Noun Screen #6 1=ZONE Noun Screen #8 Pressing 3 or 4 while viewing the Adjective/Noun Screen will display screens similar to the previous Adjective and Noun Screens. The new screens will list custom Adjectives and Nouns which have been programmed into the control panel by the user utilizing the PK-CD programming kit. These descriptors are selected as described in the previous sections. Description The Description selection allows the programmer to enter additional information about the zone currently being programmed. This information will be displayed as part of the device label on the Edit Input Zone Screen #4 display. Pressing 2 while viewing Edit Input Zone Screen #4 will cause the following screen to be displayed: ZONE # DESCRIPTION PRESS ENTER IF DONE Adjective/Noun Screen A flashing cursor will appear at the first asterisk to the left. The programmer can enter additional descriptive information about the device being programmed. This information will appear on the display along with the standard device label information. A maximum of 20 characters (including spaces) can be entered. To enter alphanumeric characters from the keypad, repeatedly press the appropriate key until the desired character is displayed in the first position. For example, to enter the letter B, press the 2 (ABC) key three times to toggle through the characters 1, A, and B. Press the right arrow key to move the cursor one position to the right and repeat the process to enter the next character. To enter a space, press the * (QZ) key four times until a blank appears in the desired position. When all characters have been entered, press the Enter key to store the information. The display will return to the Edit Input Zone Screen #4, displaying the new information at the bottom of the screen. Recall/Increment Function In addition, the user may use the Recall/Increment function at any time when the cursor is on the first letter of the Description, Adjective or Noun field as follows: • If the zero key is pressed, a 0 is placed in the first letter position MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 65 Programming Master Programming Level • If the zero key is then pressed a second time with no intervening key actions, the entire field is replaced with the field entered for the previous device programmed, and the cursor moves to the last character of the field (Recall function). The Recalled Adjective or Noun field may now be changed letter-by-letter • If the zero key is pressed again with no other intervening key actions and the last character in the field is a number 0-9, the number is incremented by one. If the last character is a letter, it changes to a 0. If the last character goes from 9 to 0 and the characters to the left of the last character are also numbers, they are also incremented (overflow) • The above increment function may be repeated with each press of the zero key As an example, the user could quickly enter ‘FLR_3_ROOM_305’ as follows: 1. The cursor is on the first letter of the Adjective field. Press the zero key twice to display FLR_3. 2. With the cursor on the first letter of the Noun field, press the zero key twice to recall the display ROOM_304. The cursor automatically jumps from the first to the last letter of the Noun field. 3. With the cursor on the last letter of the Noun field, press the zero key again to increment the room number to 305. 4. Press the Enter key to store the information. 3.5.2 NAC (Notification Appliance Circuit) PROGRAMMING 1=INPUT ZONES 2=NACS 3=RELAYS The options for the NACs on the control panel main circuit board can be configured by pressing 2 while viewing Programming Screen #2. The following screens will be displayed: Programming Screen #1 NACS 1=NAC 1 2=NAC 2 3=NAC 3 4=NAC 4 NAC Selection Screen The Notification Appliance Circuits can be configured independently by pressing 1 for NAC 1, 2 for NAC 2, 3 for NAC 3, or 4 for NAC 4. To program an NAC circuit, press the number corresponding to the NAC to be programmed. The following screens will be displayed for each selection: NAC # 1=ENABLED 2=CODING STEADY YES NAC Screen #1 NAC # 1=ENABLED 2=CODING STEADY NAC Screen #1 NAC # 1=SILENCE 2=AUTO SILENCE 3=SIL INHIBITED YES NO NO NAC Screen #2 Enabled Pressing 1 while viewing NAC Screen #1 will cause the display to change to Enabled No. This will prevent the selected main circuit board NAC from activating its devices. Each press of the 1 key will cause the display to toggle between Enabled Yes and Enabled No. Note that if a circuit is disabled, a trouble will be logged on the FACP until the circuit is enabled. 66 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Master Programming Level Programming NAC Coding The Coding feature allows the programmer to select the type of output that the main circuit board notification appliances will generate when activated. Pressing 2 while viewing NAC Screen #1 will cause the following displays to appear: CODING 1=STEADY 2=MARCH TIME 3=CALIFORNIA CODING 1=TEMPORAL 2=TWO STAGE 3 MIN 3=TWO STAGE 5 MIN Coding Screen #1 CODING 1=SYNC SYSTEM SENSR 2=SYNC WHEELOCK 3=SYNC GENTEX Coding Screen #2 CODING 1=SYNC FARADAY 2=SYNC AMSECO Coding Screen #3 Coding Screen #4 The programmer can select the notification appliance output by pressing the number corresponding to the desired output. The coding selections are: • Steady - a continuous output with no coding • March Time - 120 ppm (pulse-per-minute) output • California - 10 seconds on and 5 seconds off • Temporal - ½ second on, ½ second off, ½ second on, ½ second off, ½ second on, 1½ second off • Two Stage 3 Minutes or 5 Minutes - refer to “Two Stage Operation” on page 68 for a description of this feature • Synchronized output for System Sensor, Wheelock, Gentex, Faraday or Amseco - Refer to “Synchronized NAC Operation” on page 68 for additional information Selection of one of the above options will cause the control panel to store the information in memory and return the display to NAC Screen #1, which will display the new coding choice. Two Stage Operation Two Stage operation consists of the following: • 1st stage output - 20 ppm (pulse-per-minute) coding • 2nd stage output - Temporal coding as described above • Acknowledge button functions as the automatic alarm signal cancel button If Two Stage operation is programmed as the Coding option, the following sequence of events will occur during an alarm. 1. The on-board NACs will activate with a 1st stage output upon activation of any alarm. 2. If, after the programmed time of 3 or 5 minutes, the Acknowledge switch has not been pressed, all NACs presently in 1st stage activation will go to 2nd stage activation. 3. If an Acknowledge switch has been pressed, the Alarm LED will turn from flashing to steady. Any NACs currently in 1st stage activation will remain in 1st stage. Pressing the Acknowledge switch does not affect NACs already in 2nd stage activation. 4. If another alarm point is activated and the countdown timer is counting, the alarm point will have no effect on the NACs. 5. If another alarm point is activated and the countdown timer has stopped counting due to the Acknowledge switch being pressed, the countdown timer will restart and the NACs will respond as outlined in step 1. NACs already in 2nd stage activation will not be affected. MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 67 Programming Master Programming Level Synchronized NAC Operation Synchronization is a panel feature that controls the activation of notification appliances in such a way that all devices will turn on and off at exactly the same time. This is particularly critical when activating strobes which must be synchronized to avoid random activation and a potential hazard or confusion. The FACP can be programmed to operate with a variety of manufacturer’s devices. Maximum Number of Strobes for Synchronization The maximum current draw for a Notification Appliance Circuit cannot exceed 2.5 amps for models with the FLPS-3 power supply or 3.0 amps for models with the FLPS-7 power supply (refer to the AC Power section under“Specifications” on page 15). Refer to the manufacturer’s documentation supplied with the Strobes to determine the maximum current draw for each strobe and ensure that the circuit maximum is not exceeded. To ensure proper strobe and circuit operation, there is also a limit to the number of strobes that can be attached to each circuit. Following is a list of the strobes that have been tested with this FACP and the maximum number that can be connected to each NAC. Make sure that the NAC maximum current is not exceeded: Strobe Manufacturer System Sensor NAC # 1=SILENCE YES 2=AUTO SILENCE NO 3=SIL INHIBITED NO NAC Screen #2 FACP with FLPS-3 Power Supply: Maximum Number of Strobes FACP with FLPS-7 Power Supply: Maximum Number of Strobes 35 46 Wheelock 24 50 Gentex 22 39 Faraday 22 33 Amseco 19 34 Silence Pressing 1 while viewing NAC Screen #2 will cause the following screen to be displayed: SILENCEABLE 1=SILENCEABLE 2=NON SILENCEABLE 3=SYNC MUTE Silenceable Screen Pressing 1 while viewing the Silenceable Screen will program the selected NAC as a silenceable circuit. This will allow the NAC to be silenced by pressing the Alarm Silence key or by the Auto Silence feature. Pressing 2 while viewing the Silenceable Screen will program the selected NAC as a nonsilenceable circuit. This will prevent the selected main circuit board NAC from being silenced by pressing the Alarm Silence key or by the Auto Silence feature. Pressing 3 while viewing the Silenceable Screen will program the selected NAC as a synchronized mute circuit. Refer to “Synchronized NAC Operation” on page 68 for a description of synchronization. Important: When a Notification Appliance Circuit with a mix of audible and visual devices is programmed for Sync Mute, only the audible devices will be turned off if the Silence key is pressed or if the Autosilence feature is enabled. The visual devices (strobes, etc.) will continue to operate. 68 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Master Programming Level PROGRAM NAC # 1=SILENCEABLE YES 2=AUTO SILENCE NO 3=SIL INHIBITED NO NAC Screen #2 Programming Auto Silence The Auto Silence feature, when enabled, automatically silences all main circuit board silenceable notification appliances after a programmed length of time. To enable this feature and program the time delay before Auto Silence activation, press 2 while viewing NAC Screen #2. The following screens will be displayed: AUTO SILENCE 1=NO 2=5 MINUTES 3=10 MINUTES Auto Silence Screen #1 AUTO SILENCE 1=15 MINUTES 2=20 MINUTES 3=25 MINUTES Auto Silence Screen #2 AUTO SILENCE 1=30 MINUTES Auto Silence Screen #3 To disable the Auto Silence feature, press 1 for No while viewing Auto Silence Screen #1. To enable the Auto Silence feature, press the number corresponding to the time delay which will elapse before Auto Silence activates. This information will be stored in memory and the display will return to NAC Screen #1. Silence Inhibited The Silence Inhibit feature, when enabled, prevents the silencing of the selected main circuit board NAC for a period of one minute. Resetting the FACP will also be prevented for one minute while the NAC programmed for silence inhibit is activated. Pressing 3 while viewing NAC Screen #2 will cause a screen to be displayed with the options 1=No Silence Inhibit and 2=1 Min. Silence Inhibit. Pressing 1 will disable the Silence Inhibit feature while pressing 2 will enable a 1 minute Silence Inhibit for the selected Output. 3.5.3 Relays PROGRAMMING 1=INPUT ZONES 2=NACS 3=RELAYS Pressing 3 while viewing Programming Screen #1 will allow the programmer to configure the three main circuit board Form-C relays. The following screen will be displayed: Programming Screen #1 RELAYS 1=RELAY 1 ALARM 2=RELAY 2 TROUBLE 3=RELAY 3 SUPERV Relays Selection Screen To program Relay 1, 2 or 3, press the number corresponding to the selected relay. The following screens will appear for each relay to be programmed: RELAY TYPE 1=ALARM 2=TROUBLE 3=SUPERVISORY Relay Screen #1 RELAY TYPE 1=PROCESS MONITOR 2=AC LOSS 3=HAZARD Relay Screen #2 RELAY TYPE 1=COMM FAIL 2=MEDICAL 3=SILENCEABLE ALARM Relay Screen #3 While viewing the selected screen, press the number corresponding to the desired relay type to program the main circuit board relay. The choice will be stored in memory and the display will return to the Relay Type Screen which will show the programmed type choice. Press the Escape key to return to the Relays Selection Screen and repeat the preceding procedure for the remaining relays. NOTE: A relay programmed with the Silenceable Alarm type will deactivate when the FACP Alarm Silenced LED is illuminated. 3.5.4 System Setup System Setup allows the programmer to configure the following control panel features: • Timers: This option allows the programmer to set the PAS (Positive Alarm Sequence) time delay, Pre-Signal time delay and Waterflow time delay MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 69 Programming PROGRAMMING 1=SYSTEM SETUP 2=OPTION MODULES 3=HISTORY Programming Screen #2 Master Programming Level • Banner: This option allows the user to change the top two lines of the LCD display from the factory default readout, which is blank, to a user defined readout when the control panel is in Normal condition • Time-Date: This feature allows the programmer to set the time, display format (24 hr or 12 hr), date and daylight savings time feature into the FACP memory • Trouble Reminder: This feature, when enabled, provides an audible reminder that an alarm or trouble still exists on the FACP after the control panel has been silenced. The control panel piezo sounder will pulse once every 15 seconds during an alarm and every two minutes during a trouble condition, after the Alarm Silence or Acknowledge key is pressed. The piezo will continue to sound at these rates until the alarm or trouble condition is cleared. If the Trouble Reminder feature is not enabled and a trouble condition is not cleared within 24 hours, the panel will reactivate the trouble sounder and retransmit the trouble condition to the central station if connected • Canadian Option: This option allows the automatic programming of the FACP to Canadian specifications (refer to “Canadian Option” on page 74). Important! For Canadian Applications, this option must be set to ON prior to any other panel programming. • Charger Disable: This option allows the programmer to disable the onboard battery charger in the event an external battery charger is being used Pressing 1 for System Setup, while viewing Programming Screen #2, will cause the following screens to be displayed: SYSTEM SETUP 1=TIMERS 2=BANNER 3=TIME-DATE SYSTEM SETUP 1=TROUBLE REMIND NO 2=CANADIAN OPTION OFF 3=CHARGR DISABLE NO System Setup Screen #1 SYSTEM SETUP 1=TIMERS 2=BANNER 3=TIME-DATE System Setup Screen #2 Timers Timer delays for PAS, Pre-signal and waterflow activation can be programmed by pressing 1 while System Setup Screen #1 viewing System Setup Screen #1. The following screen will be displayed: TIMERS 1=PAS DELAY 120 2=PRE SIGNAL 120 3=WATERFLW DELAY 0 TIMERS 1=AC LOSS DELAY Timer Screen #2 Timer Screen #1 TIMERS 1=PAS DELAY 120 2=PRE SIGNAL 120 3=WATERFLW DELAY 0 Timer Screen #1 2 PAS (Positive Alarm Sequence) Delay The factory default setting for PAS is 000 for no delay. To select a PAS delay of 001 to 180 seconds for all devices programmed for PAS, press 1 while viewing Timer Screen #1. The following display will appear: PAS DELAY RANGE 000-180 SECONDS PAS Delay Screen A flashing cursor is positioned in the lower left corner of the display. Enter a delay time consisting of three digits, such as 005 for five seconds. Upon entering the third digit, the time delay will be stored in the control panel memory and the display will return to the Delay Screen which will indicate the new delay time. 70 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Master Programming Level Programming Pre-signal Delay The factory default setting for Pre-signal delay is 000 for no delay. To select a Pre-signal delay of 001 to 180 seconds for all devices programmed for Pre-signal, press 2 while viewing Timer Screen #1. The following screen will be displayed: PRESIGNAL DELAY RANGE 000-180 SECONDS Pre-signal Delay Screen A flashing cursor is positioned in the lower left corner of the display. Enter a delay time consisting of three digits, such as 009 for nine seconds. Upon entering the third digit, the time delay will be stored in the control panel memory and the display will return to the Delay Screen which will indicate the new delay time. Note that the FACP can have both PAS and Pre-signal timers programmed with values but a zone can only use either the PAS or Pre-signal feature, but not both. TIMER 1=PAS DELAY 120 2=PRE SIGNAL 120 3=WATERFLW DELAY 0 Timer Screen #1 Waterflow Delay A delay can be added prior to declaring a waterflow type of alarm. Be careful to include any builtin delays of the waterflow device. The factory default setting for Waterflow delay is 000 for no delay. To select a Waterflow delay of 01 to 90 seconds for all devices programmed for Waterflow delay, press 3 while viewing Timer Screen #1. The following screen will be displayed: WATERFLOW DELAY RANGE 00-90 SECONDS Waterflow Delay Screen A flashing cursor is positioned in the lower left corner of the display. Enter a delay time consisting of two digits, such as 25 for twenty-five seconds. Upon entering the second digit, the time delay will be stored in the control panel memory and the display will return to the Delay Screen which will indicate the new delay time. TIMER 1=AC LOSS DELAY 2 Timer Screen #2 AC Loss Delay The reporting of a loss of AC power to a central station can be delayed by programming the length of the desired delay. Press 1 while viewing Timer Screen #2 to display the following: AC LOSS DELAY RANGE 00-24 HOURS AC Loss Delay Screen #1 A flashing cursor will appear in the lower left corner of the display. The factory default setting is 02 hours. Type the two digit AC loss reporting delay in hours (00 to 24 hour delay). When the second digit is entered, the display will return to AC Loss Delay Screen #1. NOTE: Upon the loss of AC power at the control panel, relays programmed for AC Loss will transfer immediately, regardless of the AC Loss Delay setting. If no troubles other than AC Loss exist in the panel, the System Trouble relay will delay activation for the duration of the AC Loss Delay setting. MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 71 Programming SYSTEM SETUP 1=TIMERS 2=BANNER 3=TIME-DATE System Setup Screen #1 Master Programming Level Banner The top line of the display, which appears when the control panel is in normal mode, can be changed by using the Banner option. Pressing 2 while viewing System Setup Screen #1 will cause the following to be displayed: SELECT BANNER 1=FACTORY BANNER 2=USER BANNER Select Banner Screen Pressing 1 while viewing the Select Banner Screen will display the following screen: FACTORY BANNER PRESS ENTER IF OK User Defined Banner Screen #1 This screen allows the user to select the factory default Banner which will be displayed when the system is in Normal Mode of operation. Press the Enter key to accept this as the default display. Press the Escape key to cancel and return to the Select Banner Screen. Pressing 2 wile viewing the Select Banner Screen will display the following screen: USER BANNER-LINE 1 PRESS ENTER IF OK User Defined Banner Screen This screen allows the programmer to enter a custom banner. A flashing cursor will appear in the bottom left corner of the display. A maximum of 20 characters (including spaces) can be entered into the screen. After entering up to 20 characters in the screen, press Enter to store the entry. To quickly clear the current banner, press the CLR key. To enter alphanumeric characters from the keypad, repeatedly press the appropriate key until the desired character is displayed in the first position. For example, to enter the letter B, press the 2 (ABC) key three times to toggle through the characters 1, A, and B. Press the right arrow key to move the cursor one position to the right and repeat the process to enter the next character. To enter a space, press the * (QZ) key four times to place a blank in the desired position. When all characters have been entered, press the Enter key to store the information. The display will return to the Select Banner Screen. SYSTEM SETUP 1=TIMERS 2=BANNER 3=TIME-DATE Time-Date The control panel time and date can be changed by pressing 3 while viewing the System Setup Screen #1. The following screen will be displayed: System Setup Screen #1 TIME AND DATE 1=TIME 10:00 AM 2=DATE 07072007 3=CLOCK FORMAT 12HR Time-Date Screen #1 72 TIME AND DATE 1=DAYLIGHT SAVINGS Time-Date Screen #2 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Master Programming Level Programming Time To change the time, press 1 while viewing the Time-Date Screen. The following screen will be displayed: ENTER TIME AS 12HRS 1=AM 10:00 AM 2=PM Time Screen A flashing cursor is located toward the top left of the display. Below the cursor is the current time. To change the time, enter the two-digit hours followed by the two-digit minutes. The cursor will move one position to the right each time a digit is entered. After the last minutes digit is entered, the cursor will again move one position to the right. At this point enter 1 for AM or 2 for PM. The display will then return to the Time-Date Screen which will show the new time entry. If an error is made while entering a digit, press the CLR key to delete the entire entry and beginning again. Date To change the date, press 2 while viewing the Time-Date Screen. The following screen will be displayed: ENTER DATE -- MONTH DAY YEAR 07-07-2007 Date Screen A flashing cursor is located toward the top left of the display. Below the cursor is the current date. To change the date, enter the two-digit month followed by the two-digit day and then the two-digit year (07 for 2007, 08 for 2008, etc.). The cursor will move one position to the right each time a digit is entered. After the last year digit is entered, the display will return to the Time-Date Screen which will show the new date entry. If an error is made while entering a digit, press the CLR key to delete the entire entry and beginning again. Clock Format The clock can be configured to display 12 hour (AM & PM) or 24 hour (military) time. Pressing 3 while viewing the Time-Date screen will cause the display to toggle between 12HR and 24HR. Select 12HR for 12 hour display or 24HR for 24 hour display. NOTE: If the clock is changed to 24 hour (military) format, the date will change to the European standard of Day-Month-Year (for display purposes only). TIME AND DATE 1=DAYLIGHT SAVINGS Time & Date Screen #2 Daylight Savings Time Pressing 1 while viewing Time-Date Screen #2 will cause the following screens to be displayed: DAYLIGHT SAVINGS 1=ENABLED YES 2=START MONTH MAR 3=START WEEK WK 2 DAYLIGHT SAVINGS 1=END MONTH NOV 2=END WEEK WK 1 Daylight Savings Screen #1 Daylight Savings Screen #2 Pressing 1 while viewing Daylight Savings Screen #1 will cause the display to toggle between Enabled Yes and Enabled No. The control panel will automatically update the time for daylight savings time when Enabled Yes is selected. Pressing 2 while viewing Daylight Savings Screen #1 will display another screen which allows the programmer to select the month that daylight savings time will begin. In this sub-screen, pressing 1 will select March, 2 will select April, and 3 will select May. MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 73 Programming Master Programming Level Pressing 3 while viewing Daylight Savings Screen #1 will display two sub-screens which allow the programmer to select the week of the month that daylight savings time will begin. In the first subscreen, pressing 1 will select the first week, 2 will select the second week, and 3 will select the third week, while in the second sub-screen, pressing 1 will select the fourth week, and 2 will select the last week of the selected month. Pressing 1 while viewing Daylight Savings Screen #2 will display another screen which allows the programmer to select the month that daylight savings time will end. In this sub-screen, pressing 1 will select September, 2 will select October, and 3 will select November. Pressing 2 while viewing Daylight Savings Screen #2 will display two sub-screens which allow the programmer to select the week of the month that daylight savings time will end. In the first subscreen, pressing 1 will select the first week, 2 will select the second week, and 3 will select the third week, while in the second sub-screen, pressing 4 will select the fourth week, and 5 will select the last week of the selected month. SYSTEM SETUP 1=TROUBLE REMIND NO 2=CANADIAN OPTION OFF 3=CHARGR DISABLE NO System Setup Screen #2 Trouble Reminder The Trouble Reminder features causes the control panel piezo to sound a reminder ‘beep’ for alarms and troubles, after the panel has been silenced. Refer to “System Setup” on page 70, for a detailed description of this feature. Pressing 1 while viewing System Setup Screen #2 will cause the display to toggle to Trouble Rem Yes, which enables this feature. Each press of the 1 key will cause the display to toggle between Trouble Rem Yes and Trouble Rem No. Note that if the Trouble Reminder feature is not enabled, a trouble existing on the panel for more than 24 hours will cause the FACP to resound the trouble sounder. Canadian Option Pressing 2 while viewing System Setup Screen #2 will configure the FACP to comply with Canadian requirements. The display will change to Canadian Opt. On. Each press of the 2 key will cause the display to toggle between Canadian Opt. On and Canadian Opt. Off. The factory default setting is Canadian Opt. Off. For Canadian applications, remote annunciation must be done using the secondary ANN-BUS. The Canadian Options configures the FACP with the following as required by Canada: • The following zone type codes are not available: non-latching supervisory non-latching drill process monitor (latching or non-latching) hazard tornado medical alert combo autoresettable • The auto-silence feature can be enabled or disabled. If this feature is enabled, the alarm signals will be turned off after 20 minutes of activation • The installer must write in the Date of Final Assembly on the Master Marking and Warranty label, located on the FACP backbox door Charger Disable Pressing 3 while viewing System Setup Screen #2 will allow the programmer to enable or disable the onboard battery charger. If an external battery charger is being used, the onboard battery charger must be disabled. Each press of the 3 key will toggle between Chrgr Disable No and Chrgr Disable Yes. 74 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Master Programming Level Programming 3.5.5 Option Modules PROGRAMMING 1=SYSTEM SETUP 2=OPTION MODULES 3=HISTORY Programming Screen #2 Options available for the FACP include annunciators, printer connection for acquiring hardcopy printouts of panel data and onboard DACT. Pressing 2 while viewing Programming Screen #2 will display the following screen: OPTION MODULES 1=ANN-BUS 2=ON BOARD DACT ANN-BUS Pressing 1 while viewing the Option Modules screen will cause the control panel to display the following screens. ANN-BUS 1=BUS ENABLED NO 2=BUS MODULES 3=AUTO CONFIGURE ANN-BUS Screen #1 ANN-BUS 1=ANN-S/PG OPTIONS 2=ANN-80 OPTIONS 3=ANN-RLY OPTIONS ANN-BUS Screen #2 ANN-BUS 1=ANN-AUDIO OPTIONS 2=ANN-SEC ENABLE NO ANN-BUS Screen #3 A variety of ANN-BUS option modules can be installed in the FACP. These devices communicate with the FACP over the ANN-BUS terminals on the control panel. ANN-BUS Enabled The ANN-BUS must be enabled if any modules are installed on the ANN-BUS terminals. To enable the ANN-BUS, press 1 while viewing ANN-BUS screen #1 so that the display reads ANNBUS Enabled Yes. Each press of the 1 key will cause the display to toggle between ANN-BUS Enabled Yes and ANN-BUS Enabled No. BUS Modules If an ANN-BUS module is installed, press 2 while viewing ANN-BUS screen #1 to select ANNBUS addresses for the module(s). The following screen will be displayed. ANN-BUS MODULES 1=ADDR. 1 NONE 2=ADDR. 2 NONE 3=ADDR. 3 NONE On Board DACT Screen #1 Pressing the down arrow key will allow the programmer to view additional screens displaying Addresses 1 - 8. Pressing the number corresponding to the desired address will display a screen with technical information about the selected module. In the technical information screen, pressing 1 for Type will display the following screens: ANN-BUS MODULE TYPE 1=NOT INSTALLED 2=ANN-80 3=ANN-I/O Module Type Screen #1 ANN-BUS MODULE TYPE 1=ANN-S/PG 2=ANN-RLY 3=ANN-LED ANN-BUS MODULE TYPE 1=ANN-AUDIO MODULE Module Type Screen #2 Module Type Screen #3 Press the number corresponding to the module type, if any, that is installed with the selected address. This will enable the module. MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 75 Programming Master Programming Level Auto-Configure The ANN-BUS Auto-Configure features allows the programmer to quickly bring all installed ANN-BUS modules online. The software will search for all ANN-BUS modules and automatically program the device type and address into the system. Pressing 3 while viewing ANN-BUS Screen #1 will begin the Auto-Configure process and cause the following screen to be displayed: ANN-BUS AUTO-CONGFIGURE IN PROGRESS PLEASE WAIT Auto-Configure Screen PROGRAMMING 1=ANN-S/PG OPTIONS 2=ANN-80 OPTIONS 3=ANN-RLY OPTIONS ANN-BUS Screen #2 ANN-S/PG Options Screen The Printer Option allows the user to configure the optional printer. Pressing 1 while viewing the ANN-BUS Screen #2 will display the following screens: ANN-S/PG OPTIONS 1=PORT PARALLEL 2=PRINTER SUPV NO 3=OFFLINE TIMER 60 ANN-S/PG OPTIONS 1=BAUD RATE N/A 2=DATA BITS N/A 3=PARITY N/A Printer Options Screen #2 Printer Options Screen #1 ANN-S/PG OPTIONS 1=STOP BITS N/A Printer Options Screen #3 Pressing 1 for Port while viewing Printer Options screen #1 will allow the programmer to select between a Parallel and Serial Port for printer connection. Each press of the 1 key will cause the display to toggle between Port PAR (parallel) and Port SER (serial). It is important to note that the interface selected determines which options are available to the user. If the Parallel Port option is selected, the user has the option to supervise the printer and select an offline timer for the supervision by pressing 2 for Printer Supervision while viewing Print Options screen #1. Each press of the 2 key will cause the display to toggle between Printer Supv NO for no supervision and Printer Supv YES for printer supervision. Note that this option is not selectable if the Serial Port option has been selected. If the Parallel Port option is selected, the user has the ability to select an Offline Timer by pressing 3 while viewing Print Options screen #1. The resultant screen allows the programmer to program the Offline Timer for a delay of between 0 and 255 seconds before loss of printer supervision is reported as a trouble. If the Serial Port option is selected, the Printer Supv and Offline Timer options will not be available. The Baud Rate, Data Bits, Parity and Stop Bits options are only available when the Serial Port option has been selected. Pressing 1 for Baud Rate while viewing Printer Options screen #2 will cause a screen to appear which allow the user to select a Baud Rate of 19200, 9600, or 2400. Pressing 2 for Data Bits while viewing Printer Options screen #2 will cause screens to appear which allow the user to select 5, 6, 7, or 8 Data Bits. Pressing 3 for Parity while viewing Printer Options screen #2 will cause a screen to appear which allows the user to select between No Parity, Even Parity, or Odd Parity. Pressing 1 for Stop Bits while viewing Printer Options screen #3 will cause a screen to appear which allows the user to select between 0.5, 1.0, or 2.0 Stop Bits. ANN-I/O LED Zone Assignments The information displayed by LEDs on every ANN-I/O module is not programmable and will therefore be as indicated in the following table. LED 1 2 3 76 Zone (any address) AC Fault General Alarm General Supervisory MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Master Programming Level Programming 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 General Trouble Alarm Silenced Earth Fault Battery Fault Charger Fault Disable Maintenance Zone 1 Alarm Zone 2 Alarm Zone 3 Alarm Zone 4 Alarm Zone 5 Alarm Zone 6 Alarm Zone 7 Alarm Zone 8 Alarm Zone 9 Alarm Zone 10 Alarm Zone 1 Trouble Zone 2 Trouble Zone 3 Trouble Zone 4 Trouble Zone 5 Trouble Zone 6 Trouble Zone 7 Trouble Zone 8 Trouble Zone 9 Trouble Zone 10 Trouble Zone 1 Supervisory Zone 2 Supervisory Zone 3 Supervisory Zone 4 Supervisory Zone 5 Supervisory Zone 6 Supervisory Zone 7 Supervisory Zone 8 Supervisory Zone 9 Supervisory Zone 10 Supervisory ANN-80 Options Screen Pressing 2 while viewing ANN-BUS screen #2 will display the following screen: ANN-80 OPTIONS 1=PIEZO ENABLE 2=LOCK ENABLE 3=ACK BTN ENABLE ANN-80 Options Screen #1 ANN-80 OPTIONS 1=SIL BTN ENABLE 2=RST BTN ENABLE 3=DRL BTN ENABLE ANN-80 Options Screen #2 The Piezo Enable option allows the programmer to select whether the piezo sounder on any installed ANN-80 module will ever sound. Pressing 1 while viewing the ANN-80 Options Screen #1 causes the display to toggle between Piezo Enable Yes and Piezo Enable No. The Lock Enable option allows the programmer to select whether or not the ANN-80 annunciator must be unlocked by its key before any annunciator key presses will function. Pressing 2 while viewing the ANN-80 Options Screen #1 causes the display to toggle between Lock Enable Yes (annunciator must be unlocked for keys to function) and Lock Enable No (lock position is ignored). The Acknowledge Button Enable (ACK BTN ENABLE) option allows the programmer to select whether the Ack/Step button on any installed ANN-80 annunciator will function normally or always be ignored. Pressing 3 while viewing the ANN-80 Options Screen #1 causes the display to toggle between Ack Btn Enable Yes (Ack/Step button functions normally) and Ack Btn Enable No (Ack/Step button never functions). MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 77 Programming Master Programming Level The Silence Button Enable (SIL BTN ENABLE) option allows the programmer to select whether the Silence button on any installed ANN-80 annunciator will function normally or always be ignored. Pressing 1 while viewing the ANN-80 Options Screen #2 causes the display to toggle between Sil Btn Enable Yes (Silence button functions normally) and Sil Btn Enable No (Silence button never functions). The Reset Button Enable (RST BTN ENABLE) option allows the programmer to select whether the Reset button on any installed ANN-80 annunciator will function normally or always be ignored. Pressing 2 while viewing the ANN-80 Options Screen #2 causes the display to toggle between Rst Btn Enable Yes (Reset button functions normally) and Rst Btn Enable No (Reset button never functions). The Drill Button Enable (DRL BTN ENABLE) option allows the programmer to select whether the Drill button on any installed ANN-80 annunciator will function normally or always be ignored. Pressing 3 while viewing the ANN-80 Options Screen #2 causes the display to toggle between Drl Btn Enable Yes (Drill button functions normally) and Drl Btn Enable No (Drill button never functions). PROGRAMMING 1=ANN-S/PG OPTIONS 2=ANN-80 OPTIONS 3=ANN-RLY OPTIONS ANN-BUS Screen #2 ANN-RLY Options Screen Pressing 3 for ANN-RLY Options while viewing ANN-BUS Screen #2 will cause the following screen to be displayed: ANN-RLY OPTIONS 1=RELAY 1 IN ZONE 1 2=RELAY 2 IN ZONE 2 3=RELAY 3 IN ZONE 3 ANN-RLY Options Screen The ANN-RLY module provides ten Form-C relays which can be programmed for various functions. The initial screen displays Relays 1 through 3. Pressing the down arrow key will display the remaining relays for this module. To program any of the ANN-RLY relays, while viewing the appropriate ANN-RLY Option screen, press the number key corresponding to the relay to be programmed. Following is a list of the available programming options for each relay: 78 • General Alarm • General Trouble • General Supervisory • AC Loss • Waterflow Delay • Input Zone 1 • Input Zone 2 • Input Zone 3 • Input Zone 4 • Input Zone 5 • Input Zone 6 • Input Zone 7 • Input Zone 8 • Input Zone 9 • Input Zone 10 • Silenceable Alarm • Not Assigned MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Master Programming Level PROGRAMMING 1=ANN-AUDIO OPTIONS ANN-BUS Screen #3 Programming ANN-AUDIO Options Screen Pressing 1 for ANN-AUDIO Options while viewing ANN-BUS Screen #3 will cause the following screen to be displayed: ANN-AUDIO OPTIONS 1=ALL CALL ZONE 1 ANN-AUDIO Options Screen This screen shows the Input Zone that has been assigned to be the All-Call Zone. In this example, Zone 1 is the All-Call Zone. The All-Call Zone can be changed by pressing the 1 key while viewing the ANN-AUDIO Options Screen. The following screens will be displayed. ANN-AUDIO ALL CALL 1=NO ALL CALL ZONE 2=INPUT ZONE 1 3=INPUT ZONE 2 ANN-AUDIO ALL CALL 1=INPUT ZONE 3 2=INPUT ZONE 4 3=INPUT ZONE 5 All-Call Options Screen #1 All-Call Options Screen #2 ANN-AUDIO ALL CALL 1=INPUT ZONE 6 2=INPUT ZONE 7 3=INPUT ZONE 8 ANN-AUDIO ALL CALL 1=INPUT ZONE 9 2=INPUT ZONE 10 All-Call Options Screen #3 (MS-10UD Only) All-Call Options Screen #4 (MS-10UD Only) These screens allow the programmer to select which Input Zone will be assigned as the All-Call Zone. ANN-BUS 1=ANN-AUDIO OPTIONS 2=ANN-SEC ENABLE NO ANN-BUS Screen #3 OPTION MODULES 1=ANN-BUS 2=ON BOARD DACT Option Module Screen ANN-SEC Enable The ANN-SEC option must be enabled if any modules are connected to the ANN-SEC option card at J13. To enable the Secondary ANN-BUS, press 2 while viewing ANN-BUS Screen #3 so that the display reads ANN-SEC ENABLE YES. Each press of the 2 key will cause the display to toggle between ANN-SEC ENABLE YES and ANN-SEC ENABLE NO. The factory default setting is ANNSEC ENABLE NO. Onboard DACT The Onboard DACT (Digital Alarm Communicator/Transmitter) provides communication to a central station. Pressing 2 while viewing the Option Module Screen will cause the following screens to be displayed: ON BOARD DACT 1=PRIM PHONE TCH TNE 2=SCND PHONE TCH TNE 3=CENTRAL STATION ON BOARD DACT 1=SERVICE TERMINAL 2=SUPERV PHONE LINE Onboard DACT Screen 1 Onboard DACT Screen 2 Primary Phone Press 1 while viewing Onboard DACT Screen to program the type of primary phone line being connected to the DACT. The following screen will be displayed: PHONE LINE 1=TOUCHTONE 2=ROTARY 67/33 (EURO) 3=ROTARY 60/40 (U.S.) Primary Phone Type Screen Press 1 to select Touchtone dialing, 2 to select Rotary dialing with a make/break ratio of 67/33, or 3 to select Rotary dialing with a make/break ratio of 60/40. MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 79 Programming ON BOARD DACT 1=PRIM PHONE 2=SCND PHONE 3=CENTRAL STATION Master Programming Level Secondary Phone Press 2 while viewing Onboard DACT Screen 1 to program the type of secondary phone line being connected to the DACT. The following screen will be displayed: Onboard DACT Screen #1 PHONE LINE 1=TOUCHTONE 2=ROTARY 67/33 (EURO) 3=ROTARY 60/40 (U.S.) Secondary Phone Type Screen Press 1 to select Touchtone dialing, 2 to select Rotary dialing with a make/break ratio of 67/33, or 3 to select Rotary dialing with a make/break ratio of 60/40. ON BOARD DACT 1=PRIM PHONE 2=SCND PHONE 3=CENTRAL STATION Central Station Central Station programming configures the control panel DACT for contacting the central station. Pressing 3 while viewing Onboard DACT Screen 1 will cause the following screens to be disOnboard DACT Screen #1 played: CENTRAL STATION 1=REPORTING NO 2=REPORT STYLE FIRST AVAILABLE CENTRAL STATION 1=PRIMARY 2=SECONDARY 3=CALL LIMIT 0 Central Station Screen #2 Central Station Screen #1 Reporting To enable the DACT for reporting FACP activity to the central station, press 1 while viewing Central Station Screen #1 so the display reads Reporting Yes. Each press of the 1 key will toggle the display between Reporting Yes and Reporting No. Report Style The DACT can be programmed to transmit reports to primary and/or secondary central station phone numbers as a backup. Press 2 while viewing Central Station Screen #1 to display the following screen: REPORT STYLE 1=BACKUP ONLY 2=BOTH 3=FIRST AVAILABLE Backup Reporting Screen Press 1 to have all reports transmitted to the central station secondary phone number as a backup only if the primary phone line fails, 2 to transmit all reports to both the primary and secondary phone numbers all of the time, or 3 to send reports to the first available phone number. CENTRAL STATION 1=PRIMARY 2=SECONDARY 3=CALL LIMIT Central Station Screen #2 Central Station Primary and Secondary Phone Numbers Pressing 1 for Primary or 2 for Secondary, while viewing Central Station Screen #2, will display the following screens. Note that the following information must be entered for both the Primary and Secondary Central Station Phone Numbers. CENTRAL STATION # 1=TEST TIME INT 24 2=ACCOUNT CODE 0000 3=24HR T TIME 0000 Primary/Secondary Screen #1 80 CENTRAL STATION 1=PHONE NUMBER Primary/Secondary Screen #2 CENTRAL STATION 1=COMM FORMAT ADEMCO CONTACT ID 2=EVENT CODES Primary/Secondary Screen #3 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Master Programming Level CENTRAL STATION 1=TEST TIME INT 2=ACCOUNT CODE 3=24HR TST TIME Primary/Secondary Screen #1 Programming Test Time Interval Pressing 1 while viewing Primary/Secondary Screen #1 will cause the following screens to be displayed: TEST TIME INTERVAL 1=24 HOURS 2=12 HOURS 3=8 HOURS TEST TIME INTERVAL 1=6 HOURS Test Time Interval Screen #1 Test Time Interval Screen #2 The test report sent to the Central Station phone number may be sent once every 6, 8, 12 or 24 hours. Select the desired Test Time Interval by pressing the corresponding digit in the screens shown above. Account Code Pressing 2 while viewing Primary/Secondary Screen #1 will cause the following screen to be displayed: ACCOUNT CODE RANGE 0000-FFFF Account Codes Screen The Account Code, which is assigned by a Central Station, depends on the communication format being used. The Account Code screen will have a flashing cursor in the lower left corner. Program the supplied 4-digit account code using 0 - 9 and A - F keys. Enter the first digit, then press the right arrow key to move the cursor to the right, one position. Repeat the process until all digits are entered. CENTRAL STATION 1=TEST TIME INT 2=ACCOUNT CODE 3=24HR T TIME Primary/Secondary Screen #1 24 Hour Test Time Pressing 3 while viewing Primary/Secondary Screen #1 will cause the following screen to be displayed: 24 HOUR TEST TIME ENTR USING 24HR TIME RANGE 0000-2359 24 Hour Test Time Screen Use the 24 Hour Test Time screen to program the time that the DACT will transmit the 24 Hour Test to the Central Station. A flashing cursor will appear in the lower left corner of the screen. Enter a four digit number representing the test time using military time (0000 = midnight and 2359 = 11:59PM). CENTRAL STATION 1=PHONE NUMBER Phone Number Pressing 1 while viewing Primary/Secondary Screen #2 will cause the following screen to be displayed: Primary/Secondary Screen #2 PHONE NUMBER 20 NUMBERS MAXIMUM Phone Number Screen The Phone Number screen is used to enter the Central Station phone number that the DACT will be contacting. A maximum of 20 characters can be entered with valid entries being 0 - 9 and A - C where A = *, B = # and C = look for secondary dial tone for up to 2 seconds (then dial anyway). A flashing cursor will appear in the lower left corner of the screen. Enter the first digit then press the right arrow key to move the cursor to the right one position. Enter the second digit and repeat the process until all digits are entered. Press the Enter key to store the phone number in memory. MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 81 Programming Master Programming Level Enter the digits as you would like the number to be dialed. For example, if it’s necessary to dial 9 before dialing a number outside the building, you may wish to pause after dialing 9. Enter 9 followed by D for a three second pause, or E for a five second pause then the phone number followed by an F to indicate the end of the number. CENTRAL STATION 1=COMM FORMAT 2=EVENT CODES Communication Format Pressing 1 while viewing Primary/Secondary Screen #3 will cause the following screen to be disPrimary/Secondary Screen #3 played: COMM FORMAT 1=ADEMCO CONTACT ID 2=SIA-DCS-8 3=SIA-DCS-20 The Communication Format is determined by the type of receiver that the DACT is transmitting to. Consult your Central Station for proper selection or consult our factory representatives. For any format chosen, the control panel automatically programs all of the event codes. Select the Communication Format by pressing the corresponding number key while viewing the Comm Format screen. The following table describes each format: Screen Selection Communication Format Description ADEMCO CONTACT ID Contact ID, DTMF, 1400/2300 ACK SIA-DCS-8 Security Industry Association, 8 messages per call SIA-DCS-20 Security Industry Association, 20 messages per call Table 3.2 Communication Formats Event Codes Pressing 2 while viewing Primary/Secondary Screen #3 will cause the following screen to be displayed: EVENT 1=ZONE 2=ZONE 3=ZONE CODES 1 ALARM 2 ALARM 3 ALARM Event Code Screen Pressing the down arrow key allows viewing of all Events associated with the selected Communication Format. Pressing the number corresponding to the event displayed in each screen will display its default active and restoral event codes which can be customized by the programmer. For example, if Ademco Contact ID is the selected format, pressing 3 for Zone 3 Alarm will display the following screen which allows the Event Code to be changed from the default value. ZONE 3 ACTIVE 115 The following table lists the Zone Alarm Types that can be programmed for zones 1 through 10 and the corresponding Event Codes for Ademco Contact ID and SIA DCS Formats. Note that Table 3.4 on page 84, Table 3.5 on page 85, Table 3.6 on page 86 and Table 3.7 on page 87 list the default settings for Zone 1 through Zone 10. These can be changed to any of the Types listed in Table 3.3. NOTE: The third character in the SIA-DCS Format (x in the table below) represents the zone number. 82 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Master Programming Level Programming Zone Alarm Type Ademco Contact ID SIA-DCS Format Active Active Pull-Station 115 FAx Restoral FHx Waterflow 113 SAx SHx SHx Waterflow Nonsilenceable 113 SAx Combo 113 SAx SHx Combo AutoResettable Supervisory 113 SAx SHx 2-Wire Detector 111 FAx FHx Normally Open Contact 110 UAx UHx Fire 110 FAx FHx Tamper 144 TAx THx Supervisory 200 FSx FVx Supervisory AutoResettable 200 FSx FVx Medic-Alert 100 MAx MHx Hazard-Alert 150 PAx PHx Tornado-Alert 150 PAx PHx IRx Proc-Mon 200 IAx Procmon-AR 200 IAx IRx AC-Loss-Mon 301 ATx ARx Drill-Switch 604 FIx FKx Drill-Switch AutoResettable 604 FIx FKx Table 3.3 Zone Alarm Type Event Codes The following tables list all of the Events and their default Event Codes for the Ademco Contact ID and SIA-DCS Communication Formats. NOTE: A detector freeze condition will be reported as a Supervisory Event Code. MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 83 Programming Master Programming Level Ademco Contact ID Format - Primary Central Station Phone Number The information shown in Table 3.4 is automatically programmed for the Primary Central Station phone number Event Codes when Ademco Contact ID Format is selected. To disable event reporting, select the desired Event Code to be disabled and press 0 or Clear and then Enter to disable it. (Enter must be pressed to save the selection. Pressing Escape will not save the selection). Event Description Event Code Settings Active Zone Code Primary # Zone 1 - 10 Alarm 115 001 - 010 Primary # Zone 1 - 10 Disabled 570 001 - 010 Primary # Drill 604 000 Primary # AC Fault 301 000 Primary # Zone 1 - 10 Fault 380 001 - 010 Primary # Zone 1 - 10 Dirty 380 001 - 010 Primary # Earth Fault 310 000 Primary # Low Battery Fault 302 000 Primary # No Battery Fault 311 000 Primary # Telco Primary Line Fault 351 001 Primary # Telco Secondary Line Fault 352 002 Primary # NAC #1 Fault 321 001 Primary # NAC #2 Fault 322 002 Primary # NAC #3 Fault 326 003 Primary # NAC #4 Fault 327 004 Primary # NAC #1 Disable 521 001 Primary # NAC #2 Disable 522 002 Primary # NAC #3 Disable 526 003 Primary # NAC #4 Disable 527 004 Primary # Charger Fault 300 000 Primary # Comm Trouble Primary # 354 001 Primary # Comm Trouble Secondary # 354 002 Primary # Printer Fault 336 000 Primary # ANN-Bus Fault 330 000 Primary # Option Card Fault 333 000 Primary # CS CALC Fault 304 000 Primary # System Off Normal 308 000 Primary # System Test Message 602 000 Primary # System Abnormal Test Message 608 000 Primary # Upload/Download Request 411 000 Primary # Upload Successful 416 000 Primary # Download Successful 412 000 Primary # Upload/Download Failed 413 000 Primary # Voice EVAC Fault 330 000 Primary # Power Supply Sync Fault 300 000 Table 3.4 Ademco Contact ID Primary # Event Codes 84 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Master Programming Level Programming Ademco Contact ID Format - Secondary Central Station Phone Number The information shown in Table 3.5 is automatically programmed for the Secondary Central Station phone number Event Codes when Ademco Contact ID Format is selected. To disable event reporting, select the desired Event Code to be disabled and press 0 or Clear and then Enter to disable it. (Enter must be pressed to save the selection. Pressing Escape will not save the selection). Event Description Event Code Settings Active Secondary # Zone 1 - 10 Alarm 115 Secondary # Zone 1 - 10 Disabled 570 Secondary # Drill 604 Secondary # AC Fault 301 Secondary # Zone 1 - 10 Fault 380 Secondary # Zone 1 - 10 Dirty 380 Secondary # Earth Fault 310 Secondary # Low Battery Fault 302 Secondary # No Battery Fault 311 Secondary # Telco Primary Line Fault 351 Secondary # Telco Secondary Line Fault 352 Secondary # NAC #1 Fault 321 Secondary # NAC #2 Fault 322 Secondary # NAC #3 Fault 326 Secondary # NAC #4 Fault 327 Secondary # NAC #1 Disable 521 Secondary # NAC #2 Disable 522 Secondary # NAC #3 Disable 526 Secondary # NAC #4 Disable 527 Secondary # Charger Fault 300 Secondary # Comm Trouble Primary # 354 Secondary # Comm Trouble Secondary # 354 Secondary # Printer Fault 336 Secondary # ANN-BUS Fault 330 Secondary # Option Card Fault 333 Secondary # CS CALC Fault 304 Secondary # System Off Normal 308 Secondary # System Test Message 602 Secondary # System Abnormal Test Message 608 Secondary # Upload/Download Request 411 Secondary # Upload Successful 416 Secondary # Download Successful 412 Secondary # Upload/Download Failed 413 Secondary # Voice EVAC Fault 330 Secondary # Power Supply Sync fault 300 Table 3.5 Ademco Contact ID Secondary # Event Codes MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 85 Programming Master Programming Level SIA-DCS Format - Primary Central Station Phone Number The information shown in Table 3.6 is automatically programmed for the Primary Central Station phone number Event Codes when SIA-DCS Format is selected. To disable event reporting, select the desired Event Code to be disabled and press 0 or Clear and then Enter to disable it. (Enter must be pressed to save the selection. Pressing Escape will not save the selection). Event Description Event Code Settings Active Restoral Primary # Zone 1 Alarm FA1 FH1 Primary # Zone 2 Alarm FA2 FH2 Primary # Zone 3 Alarm FA3 FH3 Primary # Zone 4 Alarm FA4 FH4 Primary # Zone 5 Alarm FA5 FH5 Primary # Zone 6 Alarm FA6 FH6 Primary # Zone 7 Alarm FA7 FH7 Primary # Zone 8 Alarm FA8 FH8 Primary # Zone 9 Alarm FA9 FH9 Primary # Zone 10 Alarm FA10 FH10 Primary # Zone 1 Disabled FB1 FU1 Primary # Zone 2 Disabled FB2 FU2 Primary # Zone 3 Disabled FB3 FU3 Primary # Zone 4 Disabled FB4 FU4 Primary # Zone 5 Disabled FB5 FU5 Primary # Zone 6 Disabled FB6 FU6 Primary # Zone 7 Disabled FB7 FU7 Primary # Zone 8 Disabled FB8 FU8 Primary # Zone 9 Disabled FB9 FU9 Primary # Zone 10 Disabled FB10 FU10 Primary # Drill FI FK Primary # AC Fault AT AR Primary # Zone 1 Fault FT1 FJ1 Primary # Zone 2 Fault FT2 FJ2 Primary # Zone 3 Fault FT3 FJ3 Primary # Zone 4 Fault FT4 FJ4 Primary # Zone 5 Fault FT5 FJ5 Primary # Zone 6 Fault FT6 FJ6 Primary # Zone 7 Fault FT7 FJ7 Primary # Zone 8 Fault FT8 FJ8 Primary # Zone 9 Fault FT9 FJ9 Primary # Zone 10 Fault FT10 FJ10 Primary # Zone 1 Dirty FT1 FJ1 Primary # Zone 2 Dirty FT2 FJ2 Primary # Zone 3 Dirty FT3 FJ3 Primary # Zone 4 Dirty FT4 FJ4 Primary # Zone 5 Dirty FT5 FJ5 Primary # Zone 6 Dirty FT6 FJ6 Primary # Zone 7 Dirty FT7 FJ7 Primary # Zone 8 Dirty FT8 FJ8 Primary # Zone 9 Dirty FT9 FJ9 Primary # Zone 10 Dirty FT10 FJ10 Primary # Earth Fault ET38 ER38 Table 3.6 SIA-DCS Primary # Event Codes 86 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Master Programming Level Programming Primary # Low Battery Fault YT0 YR0 Primary # No Battery Fault YT0 YR0 Primary # Telco Primary Line Fault LT1 LR1 Primary # Telco Secondary Line Fault LT2 LR2 Primary # NAC #1 Fault ET32 ER32 Primary # NAC #2 Fault ET33 ER33 Primary # NAC #3 Fault ET34 ER34 Primary # NAC #4 Fault ET35 ER35 Primary # NAC #1 Disable ET101 ER101 Primary # NAC #2 Disable ET102 ER102 Primary # NAC #3 Disable ET103 ER103 Primary # NAC #4 Disable ET104 ER104 Primary # Charger Fault YP YQ Primary # Comm Trouble Primary # YC1 YK1 Primary # Comm Trouble Secondary # YC2 YK2 Primary # Printer Fault VT VR ET61 ER61 ET ER Primary # CS CALC Fault YF 000 Future 000 000 Primary # System Off Normal LB LX Primary # System Test Message RP 000 RP99 000 Primary # ANN-Bus Fault Primary # Option Card Fault Primary # System Abnormal Test Message Primary # Power Supply Sync Fault OU OV Primary # Upload/Download Request RB 000 Primary # Upload Successful RS 000 Primary # Download Successful RS 000 Primary # Upload/Download Failed RU 000 Primary # Voice EVAC Fault ET ER Primary # Power Supply Sync Fault OU OV Table 3.6 SIA-DCS Primary # Event Codes (Continued) SIA-DCS Format - Secondary Central Station Phone Number The information shown in Table 3.7 is automatically programmed for the Secondary Central Station phone number Event Codes when SIA-DCS Format is selected. To disable event reporting, select the desired Event Code to be disabled and press 0 or Clear and then Enter to disable it. (Enter must be pressed to save the selection. Pressing Escape will not save the selection). Event Description Event Code Settings Active Restoral Secondary # Zone 1 Alarm FA1 FH1 Secondary # Zone 2 Alarm FA2 FH2 Secondary # Zone 3 Alarm FA3 FH3 Secondary # Zone 4 Alarm FA4 FH4 Secondary # Zone 5 Alarm FA5 FH5 Secondary # Zone 6 Alarm FA6 FH6 Secondary # Zone 7 Alarm FA7 FH7 Secondary # Zone 8 Alarm FA8 FH8 Secondary # Zone 9 Alarm FA9 FH9 Secondary # Zone 10 Alarm FA10 FH10 Secondary # Zone 1 Disabled FB1 FU1 Table 3.7 SIA-DCS Secondary # Event Codes MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 87 Programming Master Programming Level Secondary # Zone 2 Disabled FB2 FU2 Secondary # Zone 3 Disabled FB3 FU3 Secondary # Zone 4 Disabled FB4 FU4 Secondary # Zone 5 Disabled FB5 FU5 Secondary # Zone 6 Disabled FB6 FU6 Secondary # Zone 7 Disabled FB7 FU7 Secondary # Zone 8 Disabled FB8 FU8 Secondary # Zone 9 Disabled FB9 FU9 Secondary # Zone 10 Disabled FB10 FU10 FI FK Secondary # Drill Secondary # AC Fault AT AR Secondary # Zone 1 Fault FT1 FJ1 Secondary # Zone 2 Fault FT2 FJ2 Secondary # Zone 3 Fault FT3 FJ3 Secondary # Zone 4 Fault FT4 FJ4 Secondary # Zone 5 Fault FT5 FJ5 Secondary # Zone 6 Fault FT6 FJ6 Secondary # Zone 7 Fault FT7 FJ7 Secondary # Zone 8 Fault FT8 FJ8 Secondary # Zone 9 Fault FT9 FJ9 Secondary # Zone 10 Fault FT10 FJ10 Secondary # Zone 1 Dirty FT1 FJ1 Secondary # Zone 2 Dirty FT2 FJ2 Secondary # Zone 3 Dirty FT3 FJ3 Secondary # Zone 4 Dirty FT4 FJ4 Secondary # Zone 5 Dirty FT5 FJ5 Secondary # Zone 6 Dirty FT6 FJ6 Secondary # Zone 7 Dirty FT7 FJ7 Secondary # Zone 8 Dirty FT8 FJ8 Secondary # Zone 9 Dirty FT9 FJ9 Secondary # Zone 10 Dirty FT10 FJ10 Secondary # Earth Fault ET38 ER38 Secondary # Low Battery Fault YT0 YR0 Secondary # No Battery Fault YT0 YR0 Secondary # Telco Primary Line Fault LT1 LR1 Secondary # Telco Secondary Line Fault LT2 LR2 Secondary # NAC #1 Fault ET32 ER32 Secondary # NAC #2 Fault ET33 ER33 Secondary # NAC #3 Fault ET34 ER34 Secondary # NAC #4 Fault ET35 ER35 Secondary # NAC #1 Disable ET101 ER101 Secondary # NAC #2 Disable ET102 ER102 Secondary # NAC #3 Disable ET103 ER103 Secondary # NAC #4 Disable ET104 ER104 Secondary # Charger Fault YP YQ Secondary # Comm Trouble Primary # YC1 YK1 Secondary # Comm Trouble Secondary # YC2 YK2 Secondary # Printer Fault VT VR ET61 ER61 Secondary # Option Card Fault ET ER Secondary # CS CALC Fault YF 000 Secondary # ANN-Bus Fault Table 3.7 SIA-DCS Secondary # Event Codes (Continued) 88 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Master Programming Level Programming Secondary # System Off Normal LB LX Secondary # System Test Message RP 000 RP99 000 Secondary # System Abnormal Test Message Secondary # Power Supply Sync Fault OU OV Secondary # Upload/Download Request RB 000 Secondary # Upload Successful RS 000 Secondary # Download Successful RS 000 Secondary # Upload/Download Failed RU 000 Secondary # Voice EVAC Fault ET ER Secondary # Power Supply Sync Fault OU OV Table 3.7 SIA-DCS Secondary # Event Codes (Continued) CENTRAL STATION 1=PRIMARY 2=SECONDARY 3=CALL LIMIT Trouble Call Limit (Dialer Runaway Prevention) The Call Limit option limits the number of DACT trouble calls to the Central Station, to a programmed amount between 0 and 99, for each unique trouble within a 24 hour period. All call limit Central Station Screen #2 counters reset (clear) at each midnight. Separate limit counters keep track of each unique type of trouble. Note that the number of phone line (communication) faults called to the Central Station are not limited by this feature. No subsequent restoral message is sent to the Central Station(s) for a particular trouble whose call limit has been reached. Local DACT annunciation will still track the particular trouble and restoral. To set the Trouble Call Limit, press 3 while viewing Central Station Screen #2. The following screen will be displayed. TROUBLE CALL LIMIT RANGE 00-99 TROUBLES Backup Reporting Screen Enter a value between 00 and 99, then press Enter to set the Call Limit to this value. NOTE: Entering a value of 00 will disable the Trouble Call Limit allowing the DACT to call the Central Station an unlimited amount of times. This is the factory default setting. DACT 1=SERVICE TERMINAL 2=SUPERV PHONE LINE Service Terminal The FACP can be programmed remotely from a PC using a modem and telephone line. InformaOnboard DACT Screen #2 tion can also be retrieved from the FACP using the same method. The Upload/Download option allows an operator to set the necessary parameters to allow the uploading and downloading of data between the FACP and PC. The Service Terminal selection provides the means for entering these parameters. Pressing 1 while viewing Onboard DACT Screen #2 will cause the following screens to appear: SERVICE TERMINAL 1=RING COUNT 0 Service Terminal Screen SERVICE TERMINAL 1=RING COUNT Service Terminal Screen #2 Ring Count The ring count designates the number of rings allowed on the phone line prior to answering an incoming call from a service terminal. The factory default is 0 which means the control panel will not answer an incoming call. This entry may be programmed for 1 to 25 rings. MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 89 Programming Master Programming Level To change the Ring Count, press 1 while viewing the Service Terminal Screen #2. The following screen will be displayed: RING COUNT RANGE 00-25 RINGS Ring Count Screen A flashing cursor will appear in the lower left corner of the display. Enter the two-digit ring count which can be a value between 00 and 25. After the second digit is entered, the display will return to the Service Terminal screen. Supervised Phone Line DACT 1=SERVICE TERMINAL 2=SUPERV PHONE LINE Onboard DACT Screen #2 The Supervised Phone Line feature allows the user to disable the supervision of Phone Line 2 by the DACT when using an alternate means of secondary transmission path. The factory default setting is Phone Line 2 supervised. Pressing 2 for Superv Phone Line while viewing Onboard DACT Screen 2 will cause the following screen to be displayed: SUPERVISE PHONE LINE 1=PHONE LINE 2 YES Each press of the 1 key while viewing this screen will toggle the option between Supervise Phone Line 2 Yes and No. 3.5.6 History PROGRAMMING 1=SYSTEM SETUP 2=OPTION MODULES 3=HISTORY The History option allows an authorized user to view or erase events which have occurred in the control panel. Pressing 3 while viewing Programming Screen #2 will display the History options as shown in the following display: Programming Screen #2 HISTORY 1=VIEW EVENTS 2=ERASE HISTORY History Screen HISTORY 1=VIEW EVENTS 2=ERASE HISTORY History Screen View Events Pressing 1 while viewing the History Screen will allow the user to select the events to be viewed as illustrated in the following: HISTORY 1=VIEW ALL 2=VIEW ALARMS 3=VIEW OTHER EVENTS View Events Screen While displaying the View Events screen, press 1 to view all events, 2 to view only alarms, or 3 to view other events. Use the up and down arrow keys to scroll through all of the displayed events. 90 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Master Programming Level Programming Erase History The Erase History option allows a user to erase all events from the history file. This will provide a clean slate in order to use the history file to track future events. Pressing 2 while viewing the History Screen will display the following screen: ERASE HISTORY PROCEED? 1=YES 2=NO Erase History Screen Pressing 1 while viewing the Erase History Screen will erase all events from the History file. After the History file has been erased, the display will return to the History Screen. 3.5.7 Walktest PROGRAMMING 1=WALKTEST 2=CLEAR PROGRAM 3=PASSWORD CHANGE Programming Screen #3 Walktest allows an individual to test the fire alarm system without the necessity to reset the control panel after each device activation. Refer to the sections titled “Walktest” on page 94 and“Walktest” on page 104 for additional information regarding the Walktest feature. Pressing 1 while viewing the Programming Screen #3 will cause the following Walktest options to be displayed: WALKTEST 1=SILENT 2=AUDIBLE 3=VIEW RESULT Walktest Screen To perform a silent walktest which will not sound the NACs, press 1 while viewing the Walktest Screen. To perform an audible walktest, which will sound the NACs, press 2 while viewing the Walktest Screen. When either option is chosen, the panel will enter Walktest Mode and the following screen will be displayed: UNIT IN WALKTEST Walktest Active Screen The user can now perform a one-person walktest by activating devices throughout the system. As each device is activated, the screen will display the information about the activated device as shown below. Note that the colon (:) in the time is replaced with an asterisk (*) to distinguish the walktest screen from an actual alarm screen. ALARM ZONE 1Z01 1000A 010805 After completion of the Walktest, press the Esc (Escape) key to exit Walktest Mode and return to the Walktest Screen. The results of the Walktest can now be viewed by pressing 3 while viewing the Walktest Screen. The following screen will be displayed: WALKTEST RESULTS Use the up and down arrow keys to view all of the walktest results which will be displayed as illustrated in the preceding screen. Note that the Walktest log is stored in RAM. If all power (AC and DC) is removed from the FACP, the Walktest log information will be lost. This information is also overwritten when subsequent walktests are performed. MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 91 Programming Master Programming Level 3.5.8 Clear Program PROGRAMMING 1=WALKTEST 2=CLEAR PROGRAM 3=PASSWORD CHANGE Pressing 2 while viewing Programming Screen #3, will select the Clear Program option. The control panel will provide a warning to the user by prompting with the following display: WARNING! SYSTEM CHANGE PROCEED? 1=YES 2=NO Programming Screen #3 Pressing 1 will cause the control panel to carry out the selected clear option. Pressing 2 will prevent programming from being cleared. OPTION MODULES 1=ANNUNCIATORS/UDACT 2=ON BOARD DACT 3=PRINTER/PC NO Option Module Screen Printer/PC A Printer or a PC can be connected to the control panel. Pressing 3 while viewing the Option Module Screen will cause the following screen to appear: PRINTER-PC 1=PRINTER NO SU 2=PRINTER SU 3=PC NO YES NO Printer-PC Screen Pressing 1 while viewing the Printer-PC Screen will program the control panel for an unsupervised (NO SU) printer. The display will change to the Printer Baud Rate Screen as shown below. Pressing 2 while viewing the Printer-PC Screen will program the control panel for a supervised (SU) printer. Printer supervision, when enabled, will typically detect the removal of the printer cable and will detect when the printer power has been turned off. Depending upon the brand of printer, other errors such as paper empty or printer off-line may be detected. The following screen will appear, which allows the programmer to select the baud rate for the printer communication: PRINTER BAUD RATE 1=2400 BAUD 2=4800 BAUD 3=9600 BAUD Printer Baud Rate Screen Pressing the number key corresponding to the desired baud rate (2 for 4800 Baud for example) will program the control panel for the selected baud rate and return the display to the Option Module Screen which will indicate Printer/PC PR4800 for a supervised printer installed at 4800 baud rate. Pressing 3 while viewing the Printer-PC Screen will program the control panel for a PC connection. The display will return to the Option Module Screen which will indicate Printer/PC PC for personal computer installed. 3.5.9 Password Change PROGRAMMING 1=WALKTEST 2=CLEAR PROGRAM 3=PASSWORD CHANGE Programming Screen #3 The factory set passwords, which have been programmed into the control panel, can be changed by selecting the Password Change option. Pressing 3 while viewing Programming Screen #3 will cause the following screen to be displayed: PASSWORD CHANGE 1=MASTER 2=MAINTENANCE 3=REMOTE DOWNLOAD Password Change Screen Press 1 to change the Master Programming Level password, 2 to change the Maintenance Level password, or 3 to change the Remote Download password. Note that the passwords will not be displayed on annunciators. 92 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Maintenance Programming Level Programming The following screen will appear when one of the change options is selected: ENTER NEW FIVE DIGIT PASSWORD Enter Password Screen A flashing cursor will appear in the center of the display. Enter a new five digit password (such as 10101 for the Master Level). After the fifth digit is entered, the following screen will be displayed: VERIFY NEW PASSWORD Password Change Screen The new five digit password must be re-entered to accept the change. The display will then return to the initial Password Change Screen. 3.6 Maintenance Programming Level To access Maintenance Programming mode, press the Enter key. The LCD will display the following: 1=READ STATUS 2=PROGRAMMING 3=REMOTE DOWNLOAD To enter the Maintenance Programming mode, press 2. The display will read as follows: PROGRAMMING ENTER PASSWORD When the Maintenance level password (default 11111) is entered, the following screen will appear: PROGRAMMING 1=INPUT ZONES 2=HISTORY 3=WALKTEST Note that in the preceding screens, an arrow appears to inform the programmer that additional options can be viewed by pressing the keypad down arrow key, as shown in the following screen. PROGRAMMING 1=TIME-DATE 3.6.1 Input Zones - Enable/Disable PROGRAMMING 1=INPUT ZONES 2=HISTORY 3=WALKTEST Maintenance Screen #1 The Zone Setup option allows the user to enable or disable desired zones. Pressing 1 for Zone Setup, while viewing Maintenance Screen #1 will cause the following screens to be displayed: POINT PROGRAM 1=ZONE 1 2=ZONE 2 3=ZONE 3 Zone Select Screen MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 93 Programming Maintenance Programming Level Pressing the down arrow key will display additional Zones (Zones 4 - 5 for MS-5UD and Zones 4 10 for MS-10UD). Select the number corresponding to the desired zone. A screen will appear which will allow enabling or disabling of the selected zone, as illustrated in the following example: ZONE 1 1=ENABLED YES Enable/Disable Select Screen Pressing 1 repeatedly will cause the display to toggle between Enabled Yes and Enabled No. 3.6.2 History Pressing 2 while viewing Maintenance Screen #1 will cause the following screen to be displayed: HISTORY 1=VIEW EVENTS 2=ERASE HISTORY History Screen The History feature allows the operator to view control panel events which have been stored in a history file in memory and erase the contents of the history file Pressing 1 while viewing the History screen will cause the following screen to be displayed: HISTORY 1=VIEW ALL 2=VIEW ALARMS 3=VIEW OTHER EVENTS To view all the events which have occurred in the control panel since the history file was last erased, press 1 while viewing the Events screen. To view only alarms/active events which have occurred, press 2 while viewing the Events screen. To view events other than alarms, press 3. The most recent event will be displayed on the screen. To view all of the selected events, press the up or down arrow keys to scroll through the list of events. If no events have occurred, the display will read NO EVENTS IN HISTORY. Pressing 2 while viewing the History Screen will cause the following screen to be displayed: ERASE HISTORY PROCEED? 1=YES 2=NO Erase History Screen Pressing 1 while viewing the Erase History Screen will erase all events from the History file. The display will then return to the History Screen. Pressing 2 will cause the display to return to the History Screen without erasing the History file. 3.6.3 Walktest PROGRAMMING 1=INPUT ZONES 2=HISTORY 3=WALKTEST Maintenance Screen #1 To perform a walktest, press 3 while viewing Maintenance Screen #1. The following screen will be displayed: WALKTEST 1=SILENT 2=AUDIBLE 3=VIEW RESULT Walktest Screen The operator can press 1 to perform a silent walktest or 2 to perform an audible walktest. The display will read UNIT IN WALKTEST. To end the Walktest, press the Esc (Escape) key. 94 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Maintenance Programming Level Programming Pressing 3 after the walktest has been completed, will allow the operator to view the results of the walktest. 3.6.4 Time-Date PROGRAMMING 1=TIME-DATE Maintenance Screen #2 To program the time and date into the control panel, press 1 while viewing Maintenance Screen #2. The following display will appear: TIME AND DATE 1=TIME 01:00 AM 2=DATE 10-09-2013 3=CLOCK FORMAT 12HRS Time and Date Screen To change the time, press 1 to display the following screen: ENTER TIME AS 12HRS : 01:00 AM 1=AM 2=PM Time Screen A flashing cursor will appear on the left side of the display. Enter the four digit number corresponding to the time (0000 - 1259). When the fourth digit is entered, the cursor will move one position to the right. Press 1 for AM or 2 for PM to complete entering the time. The display will return to the Time and Date Screen displaying the new time. To change the date, press 2 while viewing the Time and Date Screen. The following screen will be displayed: ENTER DATE -- MONTH DAY YEAR 10-15-2013 Date Screen A flashing cursor will appear on the left side of the display. Enter the two digit month, two digit day and four digit year. The cursor will move one position to the right after each entry. When the fourth digit of the year has been entered, the display will return to the Time and Date Screen which will show the new date. To change between 12 hour and 24 hour format, press 3 while viewing the Time and Date screen. Each press of the 3 key will toggle the display between 12 HR and 24 HR format. MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 95 Section 4: Operating Instructions 4.1 Panel Control Buttons 4.1.1 Acknowledge/Step The first press of the Acknowledge/Step key silences the piezo sounder, changes flashing LEDs to steady and also changes the status field on the LCD display from capital letters to small letters (TROUBL to Troubl). When the piezo is silenced, an acknowledge message is sent to the printer and the history file. Acknowledge also sends a silence piezo command to the optional annunciators connected to the FACP. The Acknowledge key will have no effect on the Notification Appliance Circuits. When more than one event exists, the first press of the Acknowledge/Step key functions as described in the preceding paragraph. Subsequent pressing of the key steps through each active event. 4.1.2 Alarm Silenced The Alarm Silenced key performs the same functions as Acknowledge/Step except it will not step through each event when multiple events are present at the panel. If an alarm exists, the Alarm Silenced key turns off all silenceable NACs (Notification Appliance Circuits) and causes the Alarm Silenced LED to turn on. It also sends an ‘alarm silenced’ message to the printer, history file and optional annunciators. A subsequent new alarm will resound the system NACs. The Alarm Silenced LED is turned off by pressing the Reset key, the Drill key or subsequent activation of the NACs. Note that if Silence Inhibit has been enabled, NACs cannot be silenced for one minute following initiation of an alarm. 4.1.3 Drill/Hold 2 Sec When the Drill key is held for a minimum of two seconds (time required to prevent accidental activations), the FACP turns on all NAC outputs and turns off the Alarm Silenced LED if it was previously on. The EVAC IN SYSTEM message is shown on the LCD display. The same message is sent to the printer and history file. The Alarm Silence key can be used to turn off all silenceable NAC outputs following activation by the Drill key. 4.1.4 Reset Pressing and releasing the Reset key turns off all NACs, temporarily turns off resettable power to 4wire detectors, causes a RESET IN SYSTEM message to be displayed on the LCD and sends the same message to the printer and history file. It also performs a lamp test by turning on all LEDs, piezo sounder and LCD display segments after the Reset key is released. Any alarm or trouble that exists after a reset will resound the system. Note that if Silence Inhibit has been enabled, the FACP cannot be reset for one minute following initiation of an alarm. 4.2 LED Indicators The five LED indicators, which are located on the front panel, operate as follows: AC Power This is a green LED which illuminates if AC power is applied to the FACP. A loss of AC power will turn off this LED 96 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Normal Operation Operating Instructions Fire Alarm This red LED flashes when one or more alarms occur. It illuminates steady when the Acknowledge/Step or Alarm Silence key is pressed. The Fire Alarm LED turns off when the Reset key is pressed. The LED will remain off if all alarms have been cleared. Supervisory This is a yellow LED that flashes when one or more supervisory conditions occur, such as a sprinkler valve tamper condition. It illuminates steady when the Acknowledge/Step or Alarm Silence key is pressed. It turns off when the Reset key is pressed and remains off if all supervisory alarms have been cleared. Trouble This is a yellow LED that flashes when one or more trouble conditions occur. It stays on steady when the Acknowledge/Step or Alarm Silence key is pressed. The LED turns off when all trouble conditions are cleared. This LED will also illuminate if the microprocessor watchdog circuit is activated. Alarm Silenced This is a yellow LED that turns on after the Alarm Silence key is pressed while an alarm condition exists. It turns off when the Drill or Reset key is pressed. 4.3 Normal Operation With no alarms or troubles in the system, the display message is System All Normal along with the current time and date as shown below. To set the time and date, refer to the appropriate section in this manual. SYSTEM ALL NORMAL 10:00A 070707 The FACP performs the following functions at regular intervals in Normal mode: Monitors AC input voltage and battery voltage Monitors and reports status option cards and control panel Refreshes LCD display and updates time Scans control panel keypad for key presses Tests memory Updates and reads all communications busses (EIA-485, etc.) i3 smoke detectors will be polled for maintenance and freeze conditions on initial entry into Normal mode. Thereafter, each device will be polled every hour for freeze and every four hours for maintenance conditions NOTE: To ensure that the system is functioning properly, the FACP will perform a freeze check five minutes after the panel is reset, followed by a maintenance check. If there is no freeze or maintenance condition, the panel will continue to monitor for freeze conditions every hour and maintenance conditions every four hours. 4.4 Trouble Operation With no alarms in the system, the detection of a trouble will cause the following: • The piezo to pulse 1 second On and 1 second Off • The system Trouble LED to flash one second On and one second Off MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 97 Operating Instructions Trouble Operation • The trouble relay to activate • TROUBL with device type, adjective/noun, address and trouble description will appear on the LCD display • The same message, along with the time and date, is sent to the optional printer and the history buffer. • Communicate the trouble conditions to the Central Station • Terminate upload or download communications Note that specific troubles will initiate additional actions; for example, loss of AC power will turn off the AC Power LED, etc. Input Zone For Input Zones, the following is a typical message that could appear on the LCD display for a device trouble: TROUBL PULL STATION ZONE 10 OPEN FAULT 10:00A 100913 The information displayed in the above example provides the following information: • First line in display: – The type of event; in this example OPEN indicating a circuit trouble – Device type identifier; in this example, PULL STATION indicates a manual device. Other device type identifiers which can be displayed include SMOKE for Smoke Detector, HEAT for Heat Detector, etc. • Second line in display: – ; refers to the user programmed adjective descriptor from library list resident in the control panel or custom entry via PC. – ; refers to the user programmed noun descriptor from library list resident in the control panel or custom entry via PC. • Third line in display indicates Zone and the fault condition. Other possible troubles include: OPEN - indicating an open circuit DIRTY - maintenance alert indicating that an i3 detector is near but below the allowed alarm limit and is in need of maintenance before the performance is compromised • Fourth line in display: – Time; the current time in this example is 10:00A which represents 10:00 AM – Date; the current month, day and year in this example is 10 for October, 09 for the 9th day of the month and 13 for the year 2013 Pressing the Acknowledge/Step or Alarm Silence key will cause the pulsing piezo to silence and the system Trouble LED to change from flashing to on steady. This block acknowledgment occurs regardless of the number of troubles, alarms and supervisory events active in the system. When the Acknowledge/Step key is pressed and at least one new alarm or trouble exists in the system, the ‘acknowledge’ message is sent to the printer and history file. If the trouble clears, either before or after the Acknowledge/Step key is pressed, the ‘clear trouble’ message is sent to the printer and history file. If all troubles clear and there are no supervisory or fire conditions active in the system, the system returns to normal mode operation and the System All Normal message is shown on the LCD display and sent to the history and printer files. The auto-restore feature will restore cleared troubles even if the troubles were never acknowledged. Note that pressing the Alarm Silence key when only troubles exist in the system will have the same effect as pressing the Acknowledge/Step key except the Alarm Silenced LED will light. 98 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Alarm Operation Operating Instructions 4.5 Alarm Operation Alarm operation is similar to trouble operation with the following differences: • The piezo sounder produces a steady output as opposed to a pulsed output • The Fire Alarm LED flashes 1 second On and 1 second Off • The LCD displays Alarm along with the device name, type, adjective/noun, associated zones and time/date • Communicate the alarm to the Central Station • Alarms latch and are not allowed to clear automatically • Timers for Silence Inhibit, Autosilence and Trouble Reminder are started • Alarms activate the alarm relay • Silenced alarms are resounded • The trouble relay is not activated • Store event in history buffer • Terminate upload or download communications A typical alarm display would be as illustrated below: ALARM PULL STATION ZONE 10 10:00A 100913 Note that the device type, which in this example is PULL STATION, can be any other programmable alarm type. The information displayed in the above example provides the following information: • First line in display: – The type of event; in this example ALARM indicating an alarm condition – Device type identifier; in this example, PULL STATION indicates a manual pull box. Other device type identifiers which can be displayed include SMOKE for Smoke Detector, HEAT for Heat Detector, etc. • Second line in display: – ; refers to the user programmed adjective descriptor from library list resident in the control panel or custom entry via PC. – ; refers to the user programmed noun descriptor from library list resident in the control panel or custom entry via PC. • Third line in display: Zone 10 indicates the zone programmed to this device which, in this example, is Input Zone 10. • Fourth line in display: – Time; the current time in this example is 10:00A which represents 10:00 AM – Date; the current month, day and year in this example is 10 for October, 09 for the 9th day of the month and 13 for the year 2013 4.6 Supervisory Operation Supervisory operation is similar to alarm operation but with the following differences: • The piezo sounder pulses ½ second On and ½ second Off • The Supervisory LED flashes ½ second On and ½ second Off • The LCD displays the status label Active Supervisory along with the device name, type, adjective/noun, associated zones and time/date MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 99 Operating Instructions Process Monitor Operation • Communicate the supervisory condition to the Central Station • The supervisory relay is activated • The alarm relay is not activated • Silenced alarms are not resounded • Timers are not started • Store event in history buffer • Terminate upload or download communications A typical Supervisory event would be displayed as illustrated in the following: FREEZE SUPERVISORY ZONE 05 FROZEN SUPRV 10:00A 100913 In the preceding example: • FROZEN SUPRV - indicates zone detector is below approximately 45oF Note that, like alarms, supervisory signals latch, except when programmed for supervisory autoresettable. Supervisory activations do not cause silenced alarms to resound, as do other alarm conditions. Open circuits in supervisory wiring are processed by the control panel the same way as other trouble conditions. Refer to “Alarm Operation” on page 99, for a description of the information displayed on the control panel LCD. 4.7 Process Monitor Operation Process Monitor operation will initiate the following events: • The piezo sounder pulses ¼ second On and ¼ second Off • The LCD displays a process monitor message along with the device name, type, adjective/noun, associated zones and time/date • Communicate the process monitor condition to the Central Station (if the default event code has been changed from 000 to a reportable event code) • Relays programmed for process monitoring will be activated • The alarm relay is not activated • Silenced alarms are not resounded • Timers are not started • Store event in history buffer • Activate appropriate LED on the ANN-LED annunciator (required for this application) Note that, like supervisories, process monitor signals latch, except when programmed for process monitor autoresettable. 4.8 Hazard/Tornado Condition Operation Hazard/Tornado operation is intended for Manual activation. Hazard/Tornado Condition operation will initiate the following events: 100 • The piezo sounder pulses ¼ second On, ¼ second Off • The LCD displays a hazard message along with the device name, type, adjective/noun, associated zones and time/date • Communicate the hazard condition to the Central Station (if the default event code has been changed from 000 to a reportable event code) • Relays programmed for hazard will be activated MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Medical Alert Condition Operation Operating Instructions • The alarm relay is not activated • Silenced alarms are not resounded • Timers are not started • Store event in history buffer • Activate appropriate LED on the ANN-LED annunciator (required for this application) Hazard conditions latch. 4.9 Medical Alert Condition Operation Medical alert operation is: • not intended for nurse call stations (applications) per UL1069. • not intended for signaling professional medical staff. • to be used for summoning security guards or other trained personnel within the facility • intended for Manual activation. Medical Alert Condition operation will initiate the following events: • The piezo sounder ¼ second On, ¼ second Off • The LCD displays a medical alert message along with the device name, type, adjective/noun, associated zones and time/date • Communicate the medical alert condition to the Central Station (if the default event code has been changed from 000 to a reportable event code) • Relays programmed for medical alert will be activated • The alarm relay is not activated • Silenced alarms are not resounded • Timers are not started • Store event in history buffer • Activate appropriate LED on the ANN-LED annunciator (required for this application) Medical alert conditions latch. 4.10 Disable/Enable Operation Input zones which are disabled do not cause an alarm or any zone activation. Disabled NACs are held in the off state. All disabled zones/NACs are treated as if they were in trouble, with the exception being the status label that will be displayed is DISABL. 4.11 Waterflow Circuits Operation If an alarm exists from a zone that is a waterflow non-silenceable type, the Alarm Silence key will not function. MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 101 Operating Instructions Detector Functions 4.12 Detector Functions Maintenance Alert i3 smoke detectors will be polled for maintenance and freeze conditions on initial entry into Normal mode. Thereafter, each device will be polled every hour for freeze and every four hours for maintenance conditions All alarm and system trouble conditions are annunciated on the control panel’s LCD. NOTE: To ensure that the system is functioning properly, the FACP will perform a freeze check five minutes after the panel is reset, followed by a maintenance check. If there is no freeze or maintenance condition, the panel will continue to monitor for freeze conditions every hour and maintenance conditions every four hours. System Alarm Verification The control panel may be programmed to perform alarm verification to help eliminate the nuisance of false alarms. Alarm verification applies to smoke detectors only. 4.13 Time Functions: Real-Time Clock The FACP includes a crystal-based clock that provides time of day, date and day of week. Time is displayed as 12 or 24 hour time with month/day/year and is stored in RAM. Daylight savings time change-over is programmable and automatic. If both AC and battery are lost, the time must be reprogrammed. 4.14 Coded Operation The NAC circuits resident on the control panel main circuit board can be programmed for coded operation. The available pulse rates which can be programmed for coded operation are as follows: • Continuous: Steady output with no pulsing • March Time: Pulses at 120 ppm (pulses per minute) • Temporal Code: Pulses at ½ second On, ½ second Off, ½ second On, ½ second Off, ½ second On, 1½ second Off • California Code: 10 seconds On, 5 seconds Off • Two-Stage: Pulses at 20 ppm (pulses per minute) for 3 or 5 minutes and then changes to Temporal 4.15 Presignal Presignal option programs an initiating device to delay the activation of NACs while allowing visual verification by a person. Once a detector triggers an alarm, the onboard piezo sounds immediately, but the NACs are not activated for a user programmed time duration of up to three minutes. Note that the alarm relay and communicator will respond to the initial alarm immediately. After the programmed delay, the NACs will activate if the source of the alarm is not cleared. Note that if a second alarm occurs during the programmed time delay, the alarm will be processed immediately, causing activation of the NACs. The events which occur upon Presignal activation are as follows: onboard piezo sounds immediately control panel LCD display will indicate a presignal event and the active zone annunciators (if enabled) will sound the local piezo, and pulse the alarm LED and zone LED 102 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Positive Alarm Sequence Operating Instructions outputs (NACs) of associated zones will be inhibited from activating for a user programmed time delay of up to three minutes second alarm occurring anytime during the time delay will cause immediate activation of all associated outputs Presignal operation requires the approval of the local Authority Having Jurisdiction. 4.16 Positive Alarm Sequence PAS (Positive Alarm Sequence) option will program a smoke detector to delay panel activation (including alarm relay and communicator) for a period of 15 seconds. When a detector triggers an alarm, the onboard piezo sounds immediately, but the NACs are prevented from activating for 15 seconds. This inhibit time is factory set and cannot be changed. Pressing the Alarm Silence or Acknowledge/Step key during the 15 second inhibit time will silence the piezo sounder and start a timer which prevents activation of NACs for an additional time duration which can be user programmed for up to three minutes. After the programmed delay, the NACs will activate if the source of the alarm is not cleared. Note that if a second alarm occurs during either time delay, the alarm will be processed immediately, causing activation of the NACs. The events which occur upon PAS activation are as follows: onboard piezo sounds immediately control panel LCD display will indicate a PAS event and the active zone annunciators (if enabled) will sound the local piezo, and pulse the alarm LED and zone LED outputs (NACs) of associated zones will be inhibited from activating for a factory set duration of 15 seconds pressing the Alarm Silence or Acknowledge/Step key will start a timer which inhibits output activation for additional time delay of up to three minutes which is user programmable second alarm occurring anytime during either time delay will cause immediate activation of all associated outputs PAS operation requires the approval of the local Authority Having Jurisdiction. 4.17 Special System Timers 4.17.1 Silence Inhibit Timer This option, if selected, prevents the Alarm Silenced and Reset keys from functioning for 60 seconds following an alarm. A new alarm during the initial 60 second period will not cause the timer to restart with a new 60 seconds. Silence Inhibit operation requires the approval of the local Authority Having Jurisdiction. 4.17.2 Autosilence Timer If Autosilence is selected, the notification appliances, programmed as silenceable, will automatically be silenced after a programmable duration of from 5 to 30 minutes. Pressing the Drill key will restart the timer. Autosilence operation requires the approval of the local Authority Having Jurisdiction. 4.17.3 Trouble Reminder If selected, this feature causes a reminding ‘beep’ every 15 seconds during an alarm (after the Alarm Silence key is pressed) and every two minutes during a trouble condition (after the Acknowledge/Step or Alarm Silence key is pressed). The ‘beeps’ from the onboard piezo sounder will occur until the alarm or fault is cleared. MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 103 Operating Instructions Walktest Note that if Trouble Reminder feature is not selected and the trouble is not cleared within 24 hours, the piezo will resound, indicating that the trouble condition still exists. 4.17.4 Waterflow Retard Timer If selected, this option will delay the activation of a waterflow type alarm for a programmable time duration from 1 to 90 seconds. This delay is in addition to any time delay inherent in the waterflow device. This feature requires the approval of the local Authority Having Jurisdiction. 4.17.5 Alarm Verification (None or One Minute) If alarm verification is selected, a smoke detector activation will cause the FACP to reset the detector by removing power for 6 seconds. Power is reapplied and a 17 second retard period begins which allows all detectors to stabilize. If no other detectors alarm, there will be no alarm indication at the FACP during the 23 second Reset/Retard period. A Confirmation period of 60 seconds follows, during which a subsequent alarm from the same detector will cause the panel to immediately activate the appropriate outputs and indicate the alarm condition at the FACP. If a different detector zone alarms any time during the first detector's Retard & Confirmation period, the panel will immediately activate all appropriate outputs and indicate the alarm condition at the FACP. If no additional detector alarms occur within 83 seconds of the first alarm (23 second Reset/Retard plus 60 second Confirmation), the timer resets and the panel is ready to verify any new detector alarms which may occur. 0 sec. 6 sec. RESET Detector Alarm Verification (Reset/Retard + Confirmation) Detector Goes Into Alarm 23 sec. RETARD Alarm Ignored Different Detector Alarms During First Detector's Verification Period 83 sec. CONFIRMATION (60 seconds) Control Panel Processes Alarm if Same Detector is Still in Alarm Control Panel Immediately Processes Alarm NOTE: Alarm Verification is available only for smoke detectors. 4.18 Walktest Walktest is a feature which allows one person to test the fire alarm system. An audible walktest will momentarily sound the Notification Appliance Circuits in the building and store the walktest information in a file at the panel. A silent walktest will not sound the NACs but will store the walktest information in a file which can be viewed at the panel. Disabled NAC devices will not activate during walktest. In addition, i3 smoke detectors will enter their own test mode causing their LEDs to flash twice every five seconds (refer to i3 specification document). Alarm/Shorted Condition When in audible Walktest, the panel responds to each new alarm and activates the NACs for four seconds. It also stores each alarm in the walktest history file which can be sent to an optional printer. The stored display will be the same as if the device actually activated except the colon (:) in the time stamp is replaced with an asterisk (*). 104 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Read Status Operating Instructions Open Condition IDCs and all main circuit board NACs are monitored for fault conditions during Walktest mode. When an open condition occurs on an IDC, the FACP will activate all enabled NACs during an audible Walktest and remain activated until the open condition is cleared. While in Walktest, the trouble relay is activated and the system Trouble LED flashes (as in all of the Program and status change operations). The alarm relay is not activated. NOTE: In Walktest, a NAC open or short fault will not cause the NACs to activate. 4.19 Read Status Read Status functions do not require a password. The control panel will continue to provide fire protection while in Read Status mode. This mode can be entered while the control panel is in alarm or trouble. If a new alarm or trouble occurs during these functions, the Read Status is exited to prevent confusion. Read Status Entry When the operator presses the control panel Enter key, the LCD will display the following: 1=READ STATUS MODE 2=PROGRAMMING MODE 3=FUTURE USE 4=REMOTE DOWNLOAD Pressing 1, while this screen is being displayed, will cause the control panel to enter the Read Status mode which allows the user to view and print the programmed features and status of the control panel. The following screens will be displayed: READ STATUS 1=SYSTEM SETTINGS 2=TIMERS 3=DAYLIGHT SAVINGS READ STATUS 1=INPUT ZONES 2=NACS 3=RELAYS Read Status Screen #1 Read Status Screen #2 READ STATUS 1=CENTRAL STATION 2=PHONE LINES 3=SERVICE TERMINAL READ STATUS 1=HISTORY 2=PRINTER 3=ANN-BUS Read Status Screen #3 Read Status Screen #4 4.19.1 Input Zones READ STATUS 1=INPUT ZONES 2=NACS 3=RELAYS Read Status Screen #1 Pressing 1 while viewing Read Status Screen #1 will cause the following screens to be displayed: INPUT ZONES 1=ZONE 1 2=ZONE 2 3=ZONE 3 Pressing the down arrow key will allow the selection of Zones 4-5 for the MS-5UD and Zones 4-10 for the MS-10UD. MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 105 Operating Instructions Read Status The operator selects the zone which is to be viewed by pressing the number corresponding to the desired zone in each screen. For example, if 1 is pressed, the display will change to a screen similar to the following: PULL STATION ZONE 1 PRESS TO VIEW Pressing the down arrow key, while viewing the screen shown above, will allow the operator to view additional programming information about the selected device, such as: • Enable/Disable Status • Device Type • Alarm Verification On/Off (for detectors) • PAS (Positive Alarm Sequence) Yes/No (for detectors only) • Pre-Signal Yes/No (for detectors only) • Input Zone Freeze Supervision • Adjective/Noun descriptor • ACC Message • Description 4.19.2 NAC Pressing 2 while viewing Read Status Screen #1 will display the following screen: NAC STATUS 1=NAC 1 3=NAC 3 2=NAC 2 4=NAC 4 The operator can press 1 to view the programmed options for NAC 1, 2 to view the programmed options for NAC 2, 3 to view the programmed options for NAC 3, or 4 to view the programmed options for NAC 4. The resulting screens will display the following information: • Enable/Disable Status • Coding Selection (Temporal, Steady, etc.) • Silenceable/Nonsilenceable • Auto Silence Enable/Disable and time delay (in minutes) • Silence Inhibit Enabled/Disabled 4.19.3 Relays READ STATUS 1=INPUT ZONES 2=NACS 3=RELAYS Read Status Screen #1 Pressing 3 while viewing Read Status Screen #1 will display the following screen: RELAY 1=RELAY 1 ALARM 2=RELAY 2 TROUBLE 3=RELAY 3 SUPERV This screen allows the operator to view the programmed option for each relay. 106 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Read Status Operating Instructions 4.19.4 System Settings READ STATUS 1=SYSTEM SETTINGS 2=TIMERS 3=DAYLIGHT SAVINGS Pressing 1 while viewing Read Status Screen #2 will display the following screens: SYSTEM SETTINGS TROUBLE REMIND NO CANADIAN OPTION OFF CHRGR DISABLE NO Read Status Screen #2 SYSTEM SETTINGS USER BANNER: XXX XXXXX XXXX XXXX The operator can view the system settings options that have been programmed into the FACP. 4.19.5 Timers READ STATUS 1=SYSTEM SETTINGS 2=TIMERS 3=DAYLIGHT SAVINGS Pressing 2 while Read Status Screen #2 will display the following screen: TIMERS PAS DELAY 120 PRE SIGNAL 120 WATERFLOW DELA 0 Read Status Screen #2 TIMERS AC LOSS DELAY 2 These screens allow the operator to view the various timer settings. 4.19.6 Daylight Savings Pressing 3 while Read Status Screen #2 will cause the following screens to be displayed: DAYLIGHT SAVINGS ENABLED NO START MONTH MAR START WEEK WK 3 DAYLIGHT SAVINGS END MONTH NOV END WEEK WK 3 These screens allow the operator to view settings that have been programmed for Daylight Savings Time. 4.19.7 History READ STATUS 1=HISTORY 2=PRINTER 3=ANN-BUS Pressing 1 while viewing Read Status Screen #3 will display the following screens: HISTORY 1=VIEW ALL 2=VIEW ALARMS 3=VIEW OTHER EVENTS Read Status Screen #3 The operator can view all events which have been stored in the history file, only alarms or other events, such as troubles or supervisories, by pressing the corresponding number key. 4.19.8 Print To print program data or control panel status, press 2 while viewing Read Status Screen #3. The following screen will be displayed: PRINT 1=HISTORY 2=WALKTEST LOG 3=EXIT PRINTING Pressing 1 while viewing the Print Screen allows the user to print the History file which will detail all of the system activities since the file was last cleared from memory. Pressing 2 while viewing the Print Screen allows the user to print the Walktest log which will detail all of the system activations during walktest since the log was last cleared. Refer to “Walktest” on page 91 for additional information on the display. Pressing 3 while viewing the Print Screen will exit the Print operation. MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 107 Operating Instructions Read Status 4.19.9 ANN-BUS READ STATUS 1=HISTORY 2=PRINTER 3=ANN-BUS Pressing 3 while viewing Read Status Screen #3 will display the settings for the ANN-BUS options as shown in the following screens: ANN-BUS BUS ENABLED NO 1=BUS MODULES 2=ANN-S/PG OPTIONS Read Status Screen #3 ANN-BUS Screen #1 ANN-BUS 1=ANN-80 OPTIONS 2=ANN-RLY OPTION 3=ANN-AUDIO OPTIONS ANN-BUS Screen #2 ANN-BUS Screen #1 indicates whether the ANN-BUS is enabled (Yes/No). Pressing 1 while viewing ANN-BUS Screen #1 will display BUS Module addresses 1-8 and the devices, if any, located at those addresses. Pressing 2 while viewing ANN-BUS Screen #1 will display the printer settings for the printer connected to the FACP. This information includes: • Serial or Parallel printer • Printer Supervision (Yes or No) • Off-line Timer setting • Baud Rate • Data Bits • Parity • Stop Bits Pressing 1 while viewing ANN-BUS Screen #2 will display the programmed options for the ANN80 devices connected to the ANN-BUS. These include Piezo enable/disable, Lock enable/disable and which buttons/keys on the annunciator are enabled/disabled. Pressing 2 while viewing ANN-BUS Screen #2 will display the zone programming for each ANNRLY relay. Pressing 3 while viewing ANN-BUS Screen #2 will display the zone, if any, that has been assigned as the All-Call Zone. 4.19.10 Central Station READ STATUS 1=CENTRAL STATION 2=PHONE LINES 3=SERVICE TERMINAL Pressing 1 while viewing Read Status Screen #4 will display the following screens: CENTRAL STATION REPORTING YES REPORT STYLE BOTH Read Status Screen #4 Central Station Screen #1 CENTRAL STATION 1=PRIMARY 2=SECONDARY 3=CALL LIMIT 0 Central Station Screen #2 Central Station Screen #1 indicates whether the Central Station Reporting is enabled or disabled and if the Reports will be sent to one or both the Primary and Secondary Central Station phone numbers. Central Station Screen #2 provides information on the Primary and Secondary Central Station programming which includes: • Test Time Interval • Account Code • 24 Hour Test Time • Phone Number • Communication Format • Event Codes This screen also displays the Call Limit for each unique DACT trouble call within a 24 hour period 108 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Read Status Operating Instructions 4.19.11 Phone Line Pressing 1 while viewing Read Status Screen #4 will display the following screen: PHONE LINES PRIMARY TCH TNE SECONDARY TCH TNE 3=SUPERV PHONE LINE The second and third lines of this screen indicate that both the Primary and Secondary phone lines have been configured for touchtone dialing operation. Pressing 1 for Superv Phone Line will cause the following screen to be displayed: SUPERVISE PHONE LINE PHONE LINE 2 YES This screen indicates whether or not Phone Line 2 is being supervised by the DACT. The factory default setting is Phone Line 2 supervised (Yes). 4.19.12 Service Terminal READ STATUS 1=CENTRAL STATION 2=PHONE LINES 3=SERVICE TERMINAL Read Status Screen #4 Pressing 3 while viewing Read Status Screen #4 will display the following screens: SERVICE TERMINAL RING COUNT 03 Service Terminal Screen The Ring Count is displayed as the first item in the Service Terminal Screen. MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 109 Section 5: Central Station Communications The control panel transmits zone and system status reports to Central Stations via the public switched telephone network. Two supervised telephone line connections are made to interface the control panel to the telephone lines. Two optional 7 foot telephone cords are available for this purpose and can be purchased separately. The control panel supervises both telephone lines for proper voltage. A delay of two minutes will occur before a fault in either phone line connection is reported as a trouble. When a fault is detected, an audible trouble signal will sound, the LCD display will indicate the phone line trouble and the trouble condition will be reported to the Central Station over the remaining operational phone line. The control panel comes with line seizure capability provided for both the primary and secondary telephone line interfaces. Any time that the control panel needs to make a call to a Central Station, line seizure will disconnect any local premises phones sharing the same telephone line. All transmissions to the Central Stations will be sent over the primary phone line. In the event of noisy phone lines, transmissions will be sent over the backup secondary phone line. Two phone numbers must be programmed, the primary Central Station phone number and the secondary Central Station phone number. All system reports will be transmitted to the primary Central Station phone number. Reports will automatically be sent to the secondary Central Station phone number if attempts to transmits to the primary Central Station phone number are unsuccessful. If 10 total attempts to communicate are unsuccessful, a Communicator Failure report will be displayed. Note that as an option, all reports may also be sent to the secondary Central Station phone number. The FACP meets NFPA 72 National Fire Code reporting requirements for: (a) the type of signal, (b) condition and (c) location of the reporting premises. The general priority reporting structure is: 110 1. Zone Alarms and Restores 2. Zone Troubles and Restores 3. System Troubles and Restores 4. 24-hour Test MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Transmittal Priorities Central Station Communications 5.1 Transmittal Priorities The integral communicator transmits highest priority events first. Events, in terms of priority, are listed below in descending order: 1. Alarms (highest priority level) Pull stations Waterflow Smoke detector Other alarm types 2. 3. Supervisory Zone System Troubles Zone disabled Fire drill AC fail (after delay) Zonal faults Earth fault Low battery Telephone line fault Notification Appliance Circuits fault Communication trouble Annunciator trouble System off normal 4. Restoral Reports Zone alarm Supervisory Zone(s) enabled Fire drill AC Zone fault Earth Battery Telephone line Notification Appliance Circuits Communication Annunciator trouble System off normal 5. 24 Hour Test (lowest priority) MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 111 Central Station Communications Transmittal Priorities 1 SIA-DCS-20 2 Ademco Contact ID FBI CP220FB (10) Radionics 6600 (6) SurGard MLR-2000 (9) Osborne Hoffman 2000E (5) SurGard System III (8) Silent Knight 9800 (4) SIA-DCS-8 SurGard MLR2 (7) Silent Knight 9500 (3) 0 Format Ademco 685 (1) Ademco MX8000 (2) The table below shows UL listed receivers which are compatible with the MS-5UD and MS-10UD. Table 5.1 Compatible UL Listed Receivers 1. With 685-8 Line Card with Rev. 4.4d software 2. With 124060V206B and 124063 Line Card Rev. B 3. With version V2.4 Receiver and 126047 Line Card Rev. G 4. With 124077V2.00 Receiver and 126047 Line Card Rev. M 5. With V.7301 Receiver S/W 6. With 01.01.03 Receiver S/W and Line Card 01.01.03 7. With software V1.86 8. With software V1.72 9. With DSP4016 and V1.6 Line Card 10. With software V3.9 IMPORTANT! It is the installer’s responsibility to ensure that the Digital Alarm Communicator/Transmitter is compatible with the Central Station Receiver, utilized by the monitoring service, prior to installation. The Compatibility Table provides a list of compatible receivers and associated software versions for the receivers. Changes in the hardware and/or software by the receiver manufacturers may affect the receiver compatibility with the FACP DACT. After completing the installation, communication between the DACT and Central Station Receiver must be tested and verified. 112 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Section 6: Local/Remote Site Upload/Download The control panel may be programmed or interrogated off-site via the public switched telephone network or locally using a USB cable. Any personal computer with Windows® XP or later, with a 2400 baud compatible modem or USB port and Upload/Download software PS-Tools on the CD ROM P/N PK-CD, may serve as a Service Terminal. This allows download of the entire program or upload of the entire program, history file, walktest data, current status, system voltages, time and date. Upload/Download Preparation The PK-CD must be placed into the personal computer CD drive and the instructions that come with it must be followed to install the PS-Tools utility onto the computer. Once that is done, the PS-Tools utility must be set up to communicate using either a USB serial port or a dial-up modem. For local USB programming, a standard male-A to male-B USB cable must be connected from the PC’s USB port to the fire panel’s USB port (J11). For remote modem programming, you must have the fire panel’s primary line telephone number entered in the PS-Tools site information screens for that site. You must also change the fire panel’s ring count from zero (the default) to answer after at least one ring. Important: Modification of FACP programming requires that the panel be enabled for download (refer to “Remote Download” on page 113). Remote interrogation of panel programming, history logs, detector status, etc., is possible without enabling the remote download option. CAUTION: After successfully downloading a program, make certain to perform the following steps: 1. Print out all programmed data via Print Mode or manually view programmed entries and compare to intended program data 2. Test all affected panel operations 3. Immediately correct any problems found 6.1 Remote Download NFPA 72 requirements state that a technician must be on-site and at the control panel whenever the Programming Utility is used to download any information to the FACP. This applies to local and remote programming. For this reason, a new option has been added to the FACP which allows an individual at the FACP to enter a password and either enable the proprietary mode where downloading will be allowed at any time or access a specific password protected screen where downloading will be allowed regardless of the current proprietary setting. The Remote Download option can be selected from the main menu screen as shown below: 1=READ STATUS MODE 2=PROGRAMMING MODE 3=FUTURE USE 4=REMOTE DOWNLOAD Pressing 4 for Remote Download while viewing the main menu will cause the following screen to be displayed: REMOTE DOWNLOAD ENTER PASSWORD The Remote Download password (default 00000) must be entered to access the Remote Download feature. Note that the default password can be changed using the Password Change option (refer to “Password Change” on page 92). MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 113 Local/Remote Site Upload/Download Transferring a Program Entering the correct password will cause the following screen to be displayed: REMOTE DOWNLOAD 1=PROPRIETARY NO 2=ACCEPT DOWNLOAD Pressing 1 for Proprietary No (factory default setting), while viewing the Remote Download screen, will cause the display to toggle from Proprietary No to Proprietary Yes. Each press of the 1 key will cause the display to toggle between Proprietary No and Proprietary Yes. Selecting Proprietary Yes will program the FACP to allow remote programming downloads from the programming utility at all times without the need to access the Remote Download screen. Pressing 2 for Accept Download will cause the following screen to be displayed: ALLOWING DOWNLOADS IF YOU EXIT THIS SCREEN DOWNLOADS WILL BE DISABLED! While this screen is displayed, remote programming downloads are allowed regardless of the Proprietary setting. Exiting this screen will disable any further downloads to the FACP. Also, following 30 minutes of inactivity (including up/downloading), the Accept Download screen will timeout, causing the display to return to the System All Normal screen. 6.2 Transferring a Program The first time that the control panel is contacted, a secret code is loaded in by a Service Terminal. Future upload or download requests cause verification of the secret code by the control panel before processing of data is allowed. If the secret code is not verified, the control panel will terminate the request. While the control panel is communicating with the remote Service Terminal, one of the DACT’s red phone line active LEDs and the green Kissoff LED will remain on steady. In order to download the panel (whether initiated at the jobsite or remotely), the following must be true: The control panel must be in the Normal Mode of operation. Downloading is not possible if the panel is in any other mode There cannot be any active communications ongoing with a Central Station receiver All active events must be successfully 'kissed-off' by the Central Station(s). The communicator must be in a standby state with no new information waiting to be transmitted to a Central Station 6.2.1 Security Features Upload and download with the control panel have been carefully designed to include key security features to ensure proper functionality. Any time a transfer is initiated, the control panel and the Service Terminal will communicate and transfer data before contacting a Central Station. When the data transfers are completed and the control panel disconnects from the Service Terminal, the control panel will call the Central Station and report one of the following conditions: • Upload/download request received • Upload and/or download request successful • Upload/download failed The key features are listed and explained in the following sections. 114 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Transferring a Program Local/Remote Site Upload/Download Secret Code Verification A secret code is stored in the control panel by a Service Terminal to prevent unauthorized access. The secret code is created at the Service Terminal by the master user and cannot be viewed or changed by anyone other than a master user. Viewing of the secret code is prohibited at the control panel. Prior to allowing an upload or download of data, the control panel will verify the secret code transmitted by the Service Terminal. Time-out at Control Panel Upon answering an incoming (modem) call on the primary Central Station phone line, the control panel will listen for a modem connection signal. If this signal is not received within 50 seconds, the control panel will disconnect the call. Upon successful connection (secret code verified), if no communication occurs within 30 minutes, the panel will disconnect the call. Upon time-out, transfer activity will be reported to the Central Station (if enabled) and the connection will be terminated. Error Checking As each block of data is received by the control panel, it is checked for accuracy. If an error is detected, the block is retransmitted until correct, up to a maximum of four times. If the Secret Code is not verified and four errors occur, the call is disconnected and the report that the upload/download was not successful is called to the Central Station(s). Central Station Data Protection The primary and secondary Central Station phone numbers, communications format, account code, test time and programmable event codes are vital Central Station information. These blocks of data are protected from partial programming due to faulty phone connections, line noise and other errors. This prevents the panel from being confused due to a wrong phone number, account code, test time and most critical formatting errors. MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 115 Section 7: Power Supply Calculations 7.1 Overview This section contains instructions and tables for calculating power supply currents in alarm and standby conditions. This is a four-step process, consisting of the following: 1. Calculating the total amount of AC branch circuit current required to operate the system 2. Calculating the power supply load current for non-fire and fire alarm conditions and calculating the secondary (battery) load 3. Calculating the size of batteries required to support the system if an AC power loss occurs 4. Selecting the proper batteries for your system 7.2 Calculating the AC Branch Circuit The control panel requires connection to a separate, dedicated AC branch circuit, which must be labeled FIRE ALARM. This branch circuit must connect to the line side of the main power feed of the protected premises. No other non-fire alarm equipment may be powered from the fire alarm branch circuit. The branch circuit wire must run continuously, without any disconnect devices, from the power source to the control panel. Overcurrent protection for this circuit must comply with Article 760 of the National Electrical Codes as well as local codes. Use 14 AWG (2.00 mm2) wire with 600 volt insulation for this branch circuit. Use Table 7.1, to determine the total amount of current, in AC amperes (A), that must be supplied to the system. Number of Devices Device Type Current Draw (AC amps) MS-5UD-3/MS-10UD-3 or MS-5UD-7(C)/MS-10UD-7(C) Total Current per Device 1.00 3.90 or 1 X = MS-5UD-3E/MS-10UD-3E or MS-5UD-7E/MS-10UD-7E 0.54 2.20 [ ] X [ ] = [ ] X [ ] = Sum Column for AC Branch Current Required = Table 7.1 AC Branch Circuit Requirements 116 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Calculating the System Current Draw Power Supply Calculations 7.3 Calculating the System Current Draw 7.3.1 Overview The control panel must be able to power all internal and external devices continuously during the non-fire alarm condition. To calculate the non-fire alarm load on the system power supply when primary power is applied, use Calculation Column 1 in Table 7.3 on page 118. The control panel must support a larger load current during a fire alarm condition. To calculate the fire alarm load on the power supply, use Calculation Column 2 in Table 7.3 on page 118. The secondary power source (batteries) must be able to power the system during a primary power loss. To calculate the non-fire alarm load on the secondary power source, use Calculation Column 3 in Table 7.3 on page 118. When calculating current draw and the battery size, note the following: • ‘Primary’ refers to the main power source for the control panel • ‘Secondary’ refers to the control panel’s backup batteries • All currents are given in amperes (A). Section 7.2 shows how to convert milliamperes and microamperes to full amperes. To convert... Milliamperes (mA) to amperes (A) Microamperes (µA) to amperes (A) Multiply mA x 0.001 µA x 0.000001 Example 3 mA x 0.001 = 0.003A 300 µA x 0.000001 = 0.0003 A Table 7.2 Converting to Full Amperes 7.3.2 How to Use Table 7.3 on page 118 to Calculate System Current Draw Use Table 7.3 on page 118 to calculate current draws as follows: 1. Enter the quantity of devices in all three columns 2. Enter the current draw where required. Refer to the Device Compatibility Document for compatible devices and their current draw 3. Calculate the current draws for each in all columns 4. Sum the total current for each column 5. Copy the totals from Column 2 and Column 3 to Table 7.4 on page 119 Following are the types of current that can be entered into Table 7.3 on page 118: Calculation Column 1 - The primary supply current load that the control panel must support during a non-fire alarm condition, with AC power applied. Calculation Column 2 - The primary supply current load that the control panel must support during a fire alarm condition, with AC power applied. Calculation Column 3 - The standby current drawn from the batteries in a non-fire alarm condition during a loss of AC power. MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 117 Power Supply Calculations Calculating the System Current Draw Table 7.3 contains three columns for calculating current draws. For maximum output current availability per circuit and per panel, refer to Section 1.2, “Specifications”, on page 15. For each column, calculate the current and enter the total (in amperes) in the bottom row. When finished, copy the totals from Calculation Column 2 and Calculation Column 3 to Table 7.4 on page 119. Device Type Calculation Column 1 Primary, Non-Fire Alarm Current (amps) X[current draw]= Qty Main Circuit Board MS-5UD or MS-10UD Calculation Column 3 Secondary, Non-Fire Alarm Current (amps) Calculation Column 2 Secondary, Fire Alarm Current (amps) Total X [current draw] = Qty X[0.214]1, X[0.110]= 1 2 Total X[current draw]= Qty Total X[0.110]= = 1 1 X[0.282]1, 2= X[0.133]= X[0.133]= CAC-5X [ ] X[0.001]= [ ] X[0.001]= [ ] X[0.001]= 4XTMF [ ] 1 max. X[0.005]= [ ] 1 max. X[0.011]1= [ ] 1 max. X[0.005]= ANN-SEC card [ ] 1 max. X[0.003]= [ ] 1 max. X[0.003]= [ ] 1 max. X[0.003]= ANN-80(C) [ ] X[0.037]= [ ] X[0.040]= [ ] X[0.015]= ANN-I/O [ ] X[0.035]= [ ] X[0.200]= [ ] X[0.035]= ANN-RLY [ ] X[0.015]= [ ] X[0.075]= [ ] X[0.015]= ANN-(R)LED3 [ ] X[0.028]= [ ] X[0.068]= [ ] X[0.028]= ANN-S/PG [ ] X[0.045]= [ ] X[0.045]= [ ] X[0.045]= 2-wire Detector Heads [ ] X[ ] 4= [ ]5 X[0.040]= [ ] X[ ] 4= 4-wire Detector Heads [ ] X[ ] 4= [ ]5 X[0.040]= [ ] X[ ] 4= Power Supervision Relays6 [ ] X[0.025]= [ ] X[0.025]= [ ] X[0.025]= NAC #1 [ ] X[ ]= NAC #2 [ ] X[ ]= NAC #3 NAC #4 Current Draw from TB9 (nonalarm) [ ]= [ ]= [ ]= Sum each column7 for totals Primary Non-Alarm = Secondary Alarm = Secondary Non-Alarm = Table 7.3 System Current Draw Calculations 1 If using the Reverse Polarity Alarm output, add 0.005 amps; if using the Reverse Polarity Trouble output, add another 0.005 amps. 2 The current draw shown represents one zone (IDC) on the main circuit board in alarm. One zone consumes 0.040 amps. 3 An ANN-LED is supplied standard with the MS-5UDC and MS-10UDC. 4 Refer to the Device Compatibility Document for standby current. 5 Enter the number of IDCs used minus one. 6 Must use compatible listed Power Supervision Relay. 7 Total current draw listed above cannot exceed 3.25 amps for the MS-5UD-3(E), 3.28 for the MS-10UD-3(E), 7.25 for the MS-5UD-7(C/E), and 7.28 for the MS-10UD-7(C/E). 118 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Calculating the Battery Size Power Supply Calculations 7.4 Calculating the Battery Size Use Table 7.4 to calculate the total Standby and Alarm load in ampere hours (AH). This total load determines the battery size (in AH), required to support the control panel under the loss of AC power. Complete Table 7.4 as follows: 1. Enter the totals from Table 7.3 on page 118, Calculation Columns 2 and 3 where shown 2. Enter the NFPA Standby and Alarm times (refer to ‘NFPA Requirements’ below) 3. Calculate the ampere hours for Standby and Alarm, then sum the Standby and Alarm ampere hours 4. Multiply the sum by the derating factor of 1.2 to calculate the proper battery size (in AH) 5. Write the ampere hour requirements on the Protected Premises label located inside the cabinet door Secondary Standby Load (total from Table 7.3 Calculation Column 3) [ ] Required Standby Time (24 hours) Secondary Alarm Load (total from Table 7.3 Calculation Column 2) [ ] Required Alarm Time (for 5 min., enter 0.084, for 10 min., enter 0.168) X[ ] X[ ] = AH = AH Sum of Standby and Alarm Ampere Hours = AH Multiply by the Derating Factor X 1.2 Battery Size, Total Ampere Hours Required = AH Table 7.4 Total Secondary Power Requirements at 24 VDC 7.4.1 NFPA Battery Requirements NFPA 72 Local, Central and Proprietary Fire Alarm Systems require 24 hours of standby power followed by 5 minutes in alarm 7.4.2 Selecting and Locating Batteries Select batteries that meet or exceed the total ampere hours calculated in Table 7.4. The control panel can charge batteries in the 7 AH to 26 AH range. The control panel cabinet is capable of housing batteries up to 18 AH. Batteries larger than 18 AH require the BB-26, BB-55, or other UL listed external battery cabinet. For Canadian applications, the minimum battery size is 12 AH and the maximum battery size is 18AH. MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 119 Appendix A: Ademco Contact ID Format Event Code Descriptions This appendix describes the various Event Codes and their messages which are available for the Ademco Contact ID Format. A.1 Transmission Format Between DACT and Receiver The transmission string for the Ademco Contact ID Format is as follows: SSSS 18 QXYZ GG CCC where SSSS = Four digit Subscriber ID Account Code 18 = Identifies transmission as Contact ID to the receiver at the Central Station Q = Event Qualifier where 1 = New Event and 3 = New Restore XYZ = Event code GG = Group number CCC = Zone number Notes: 1. 18, which is used in the reporting structure to identify the transmission as Contact ID, is not printed out in the alarm and trouble report. 2. GG Group Number is fixed at '00' and cannot be changed. 3. CCC for Zone Number is transmitted as ‘001’ for zone 1 up to ‘010’ for zone 10 A.2 Ademco Contact ID Typical Printout A typical printout from a Central Station receiver (such as the Ademco 685) of alarm and trouble reports in the Ademco Contact ID Reporting Structure follows: Time Date Rcvr/Line ID SSSS QXYZ GG 11:28 03/25 11 7777 E110 00 C001 - general fire alarm on zone one CCCC 11:28 03/25 11 7777 E111 00 C002 - smoke detector alarm on zone two 11:28 03/25 11 7777 E380 00 C003 - fault on zone three 11:28 03/25 11 7777 E570 00 C009 - Zone nine disabled 11:28 03/25 11 7777 R110 00 C001 - Zone one alarm restored 11:28 03/25 11 7777 R111 00 C002 - smoke detector zone two restored 11:28 03/25 11 7777 R380 00 C003 - zone three fault restored 11:28 03/25 11 7777 R570 00 C009 - zone nine reenabled 11:28 03/25 11 7777 E158 00 C006 - high temperature, zone six 11:28 03/25 11 7777 E151 00 C007 - gas detected, zone seven Notes: 120 1. 11 is an example of a Receiver/Line Card, showing which receiver and line card the message was transmitted to. 2. Q, which is the Event Qualifier for the reporting structure, is printed out in the report as an E for New Event or R for New Restore. MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Ademco Contact ID Typical Printout Ademco Contact ID Format Event Code Descriptions EVENT CODE CLASSIFICATIONS 100 ALARMS Medical Fire Panic Burglary General 24 Hour 200 300 SUPERVISORY TROUBLES Fire System Sounder/Relay System Peripheral Communication Protective Loop Sensor EVENT 500 DISABLES/ BYPASSES 400 OPEN/CLOSE REMOTE ACCESS Open/Close Remote Access Access Control System Sounder/Relay System Peripheral Communication 600 TEST/ MISC. Test MESSAGE Medical Alarms - 100 100 Medical EMERG - Personal Emergency - # 101 Pendant Transmitter EMERG - Personal Embergency - # 102 Fail to report in EMERG - Fail to Check-in - # Fire Alarm - 110 110 Fire Alarm FIRE - Fire Alarm - # 111 Smoke FIRE - Smoke Detector - # 112 Combustion FIRE - Combustion - # 113 Waterflow FIRE - Waterflow - # 114 Heat FIRE - Heat Sensor- # 115 Pull station FIRE - Pull Station - # 116 Duct FIRE - Duct Sensor - # 117 Flame FIRE - Flame Sensor - # 118 Near Alarm FIRE - Near Alarm - # Panic Alarms - 120 120 Panic Alarm PANIC - Panic - # 121 Duress PANIC - Duress 122 Silent PANIC - Silent Panic - # 123 Audible PANIC - Audible Panic - # Burglar Alams - 130 130 Burlgary BURG - Burglary - # 131 Perimeter BURG - Perimeter - # 132 Interior BURG - Interior - # 133 24-Hour BURG - 24-Hour - # 134 Entry/Exit BURG - Entry/Exit - # 135 Day/Night BURG - Day/Night - # 136 Outdoor BURG - Outdoor - # 137 Tamper BURG - Tamper - # 138 Near Alarm BURG - Near Alarm - # General Alarms - 140 140 General Alarm ALARM - General Alarm - # 141 Polling loop open ALARM - Polling Loop Open - # MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 121 Ademco Contact ID Format Event Code Descriptions Ademco Contact ID Typical Printout EVENT MESSAGE 142 Polling loop short ALARM - Polling Loop Short - # 143 Expansion module failure ALARM - Exp. Module Fail - # 144 Sensor tamper ALARM - Sensor Tamper - # 145 Expansion module tamper ALARM - Exp. Module Tamper - # 24 Hour Non-Burlary - 150 and 160 150 24-Hour Non-Burg ALARM - 24-Hr. Non-Burg - # 151 Gas detected ALARM - Gas Detected - # 152 Refrigeration ALARM - Refrigeration - # 153 Loss of heat ALARM - Heating System - # 154 Water leakage ALARM - Water Leakage - # 155 Foil break ALARM - Foil Break - # 156 Day trouble ALARM - Day Trouble - # 157 Low bottled gas level ALARM - Low Gas Level - # 158 High temp ALARM - High Temperature - # 159 Low temp ALARM - Low Temperature - # 161 Loss of air flow ALARM - Air Flow - # Fire Supervisory - 200 and 210 200 Fire supervisory SUPER. - Fire Supervisory - # 201 Low water pressure SUPER. - Low Water Pressure - # 202 Low CO2 SUPER. - Low CO2 203 Gate valve sensor SUPER. - Gate Valve - # 204 Low water level SUPER. - Low Water Level - # 205 Pump activated SUPER. - Pump Activation - # 206 Pump failure SUPER. - Pump Failure - # System Troubles - 300 and 310 300 System trouble TROUBLE - System Trouble 301 AC loss TROUBLE - AC Power 302 Low system battery TROUBLE - System Low Battery 303 RAM checksum bad TROUBLE - BAD RAM Checksum (restore not applicable) 304 ROM checksum bad TROUBLE - BAD ROM Checksum (restore not applicable) 305 System reset TROUBLE - System Reset (restore not applicable) 306 Panel program changed TROUBLE - Programming Changed (restore not applicable) 307 Self-test failure TROUBLE - Self Test Failure 308 System shutdown TROUBLE - System Shutdown 309 Battery test failure TROUBLE - Battery Test Failure 310 Ground fault TROUBLE - Ground Fault - # 311 No battery TROUBLE - No Battery Sounder/Relay Troubles - 320 122 320 Sounder/Relay TROUBLE - Sounder/Relay - # 321 Bell 1 TROUBLE - Bell/Siren - #1 322 Bell 2 TROUBLE - Bell/Siren - #2 323 Alarm relay TROUBLE - Alarm Relay 324 Trouble relay TROUBLE - Trouble Relay 325 Reversing TROUBLE - Reversing Relay 326 Bell 3 TROUBLE - Bell/Siren - #3 327 Bell 4 TROUBLE - Bell/Siren - #4 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Ademco Contact ID Typical Printout EVENT Ademco Contact ID Format Event Code Descriptions MESSAGE System Peripheral Troubles - 330 and 340 330 System peripheral TROUBLE - Sys. Peripheral - # 331 Polling loop open TROUBLE - Polling Loop Open 332 Polling loop short TROUBLE - Polling Loop Short 333 Expansion module failure TROUBLE - Exp. Module Fail - # 334 Repeater failure TROUBLE - Repeater Failure - # 335 Local printer paper out TROUBLE - Printer Paper Out 336 Local printer failure TROUBLE - Local Printer Communication Troubles - 350 and 360 350 Communication TROUBLE - Communication Trouble 351 Telco 1 fault TROUBLE - Phone Line #1 352 Telco 2 fault TROUBLE - Phone Line #2 353 Long range radio xmitter fault TROUBLE - Radio Transmitter 354 Fail to communicate TROUBLE - Fail to Communicate 355 Loss of radio supervision TROUBLE - Radio Supervision 356 Loss of central polling TROUBLE - Central Radio Polling Protection Loop Troubles - 370 370 Protection loop TROUBLE - Protection Loop - # 371 Protection loop open TROUBLE - Protection Loop Open - # 372 Protection loop short TROUBLE - Protection Loop Short - # 373 Fire trouble TROUBLE - Fire Loop - # Sensor Troubles - 380 380 Sensor trouble TROUBLE - Sensor Trouble - # 381 Loss of supervision - RF TROUBLE - RF Sensor Supervision - # 382 Loss of supervision - RPM TROUBLE - RPM Sensor Supervision - # 383 Sensor tamper TROUBLE- Sensor Tamper - # 384 RF transmitter low battery TROUBLE - RF Sensor Batt. - # Open/Close - 400 400 Open/Close OPENING CLOSING 401 Open/Close by user OPENING - User # CLOSING - User # 402 Group Open/Close OPENING - Group User # CLOSING - Group User # 403 Automatic Open/Close OPENING - Automatic CLOSING - Automatic 404 Late Open/Close OPENING - Late CLOSING - Late 405 Deferred Open/Close Opening not used Closing not used 406 Cancel OPENING - Cancel Closing not used 407 Remote arm/disarm OPENING - Remote CLOSING - Remote 408 Quick arm Opening not applicable CLOSING - Quick Arm 409 Keyswitch Open/Close OPENING - Keyswitch CLOSING - Keyswitch REMOTE - Callback Requested (restore not applicable) Remote Access - 410 411 Callback request made 412 Success - download/access REMOTE - Successful Access (restore not applicable) 413 Unsuccessful access REMOTE - Unsuccessful Access (restore not applicable) 414 System shutdown REMOTE - System Shutdown 415 Dialer shutdown REMOTE - Dialer Shutdown 416 Success - upload/access REMOTE - Successful Access MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 (restore not applicable) 123 Ademco Contact ID Format Event Code Descriptions EVENT Ademco Contact ID Typical Printout MESSAGE Access Control - 420 421 Access denied ACCESS - Access Denied - User # (restore not used) 422 Access report by user ACCESS - Access Gained - User # (restore not used) System Disables - 500 and 510 Sounder/Relay Disables - 520 520 Sounder/Relay disable DISABLE - Sounder/Relay - # 521 Bell 1 disable DISABLE - Bell/Siren - #1 522 Bell 2 disable DISABLE - Bell/Siren - #2 523 Alarm relay disable DISABLE - Alarm Relay 524 Trouble relay disable DISABLE - Trouble Relay 525 Reversing relay disable DISABLE - Reversing Relay 526 Bell 3 disable DISABLE - Bell/Siren - #3 527 Bell 4 disable DISABLE - Bell/Siren - #4 System Peripheral Disables - 530 and 540 Communication Disables - 550 and 560 551 Dialer disabled DISABLE - Dialer Disable 552 Radio transmitter disabled DISABLE - Radio Disable Bypasses - 570 570 Zone bypass BYPASS - Zone Bypass - # 571 Fire bypass BYPASS - Fire Bypass - # 572 24-Hour zone bypass BYPASS - 24-Hour Bypass - # 573 Burglar bypass BYPASS - Burg. Bypass - # 574 Group bypass BYPASS - Group Bypass - # Test Misc. - 600 124 601 Manual trigger test TEST - Manually Triggered (restore not applicable) 602 Periodic test report TEST - Periodic (restore not applicable) 603 Periodic RF transmission TEST - Periodic Radio (restore not applicable) 604 Fire test TEST - Fire Test (restore not used) 605 Status report to follow STATUS - Status Follows (restore not applicable) 606 Listen-in to follow LISTEN - Listen-in Active (restore not applicable) 607 Walk test mode TEST - Walk Test Mode 608 System abnormal test TEST - System Abnormal Test MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Appendix B: NFPA Standard-Specific Requirements The MS-5UD/MS-10UD has been designed for use in commercial, industrial and institutional applications and meets the requirements for service under the National Fire Protection Association (NFPA) Standards outlined in this Appendix. The minimum system components required for compliance with the appropriate NFPA standard are listed below: MS-5UD/MS-10UD Control Panel Contains the main control board, cabinet (backbox and door), main power supply and transformer. Batteries Refer to “Power Supply Calculations” on page 116, for Standby Power Requirements. Initiating Devices Connected to one of the control panel's Initiating Device Circuits. Notification Appliances Connected to the control panel's Notification Appliance Circuits via a control module. The following additional equipment is needed for compliance with the NFPA 72 standards listed below: NFPA 72 NATIONAL FIRE ALARM STANDARDS FOR: NFPA 72 Central Station Service (Protected Premises Unit) or Remote Station Service Onboard Digital Alarm Communicator Transmitter for connection to a compatible listed Central Station DACR or Protected Premises Receiving Unit. This unit must be installed as outlined in “Digital Alarm Communicator/Transmitter” on page 21. OR 411UD may be installed as illustrated in Figure B.1, “MS-5UD/MS-10UD FACP Connection to 411UD,” on page 126. OR 4XTMF Transmitter Module for connection to the RS82 Remote Station Receiver. See Figure B.3, “Remote Station Connection Using 4XTMF Module,” on page 128, for installation instructions for this unit. NFPA 72 Auxiliary Fire Alarm System 4XTMF Transmitter Module for connection to a compatible listed Local Energy Municipal Box. This unit must be installed as illustrated in the section titled “4XTMF Transmitter Module Installation” on page 39 and as outlined in Figure B.2, “Municipal Box Connected to 4XTMF Transmitter Module,” on page 127. NFPA 72 Proprietary Fire Alarm System MS-5UD/MS-10UD Alarm, Trouble and Supervisory contacts connected to Transmitter(s). See Figure B.4, “Proprietary Protective Signaling System,” on page 129, for installation instructions for this unit. MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 125 NFPA Standard-Specific Requirements The following figure illustrates an example of Central Station/Remote Station Reporting using a 411UD. The relay contacts from the MS-5UD/MS-10UD may be used to trip any dialer UL listed for Central Station/Remote Station Reporting Services. 411UD Channel1 Channel 2 Channel 3 Channel 4 (2.2K ELR) Jumper -VDC to Trouble Relay contact + 24 VDC nonresettable power - 24 VDC nonresettable power 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 9 J4 Not Installed Relay Output (DACT Trouble) from 411UD FACP Supervisory Relay FACP Trouble Relay FACP Alarm Relay 2.2K ELRs P/N 27070 1234567 FACP Trouble Input (non-supervised, power-limited) Figure B.1 MS-5UD/MS-10UD FACP Connection to 411UD Alarm Trouble Supervisory 411UD FACP TB2-1 TB8-1 TB2-2 TB8-3 TB2-3 TB8-4 TB2-4 TB8-6 TB2-5 TB8-7 TB2-6 TB8-9 Table B.1 411UD Connections to FACP 126 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 NFPA Standard-Specific Requirements Notes: 1. Reference the 411UD Manual for additional information 2. Program the 411UD for slave operation 3. The MS-5UD/MS-10UD must be programmed for AC Loss Reporting Delay This prevents the immediate transmission of a trouble on the loss of AC power 4. All connections between the control panel and the 411UD must be in conduit, less than 20 feet (610 cm) in length, in the same room 5. Any zone of the 411UD can be wired to function as alarm, trouble or supervisory. In Figure B.1 on page 126, Channel 1/Zone 1 is wired to the control panel’s alarm relay, Channel 2/Zone 2 is wired to the control panel’s trouble relay and Channel 3/Zone 3 is wired to the control panel’s supervisory relay 6. Nonresettable 24 VDC power is supplied to the 411UD via TB9 terminals configured for nonresettable power on the FACP. Jumper J4 on the 411UD must be removed for 24 VDC power 7. End-of-Line resistors must terminate all 411UD circuits, including unused circuits 8. A -VDC from the 411UD Trouble Contacts will activate the Trouble Input J6 on the FACP NFPA 72 Auxiliary Fire Alarm System All connections are power-limited and supervised. This application is not suitable for separate transmission of sprinkler supervisory or trouble conditions. Notes: 1. 3 ohms maximum loop resistance allowed for wiring from control panel to Municipal Box. 2. Cut JP30 on the MS-5UD/MS-10UD main circuit board to supervise placement of 4XTMF module and circuit. 3. Cut JP24 on the MS-5UD/MS-10UD main circuit board to enable FACP Supervisory relay. 4. Refer to “4XTMF Transmitter Module Installation” on page 39 for detailed information. FIRE + Municipal Box Circuit - Polarities shown in alarm condition Nonpower-limited + Gamewell Model M34-56 Local Energy Municipal Box - 4XTMF Figure B.2 Municipal Box Connected to 4XTMF Transmitter Module MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 127 NFPA Standard-Specific Requirements NFPA 72 Remote Station Protective Signaling System Notes: 1. Cut Jumper JP30 on the MS-5UD/MS-10UD main circuit board to supervise placement of the 4XTMF module. 2. Refer to“4XTMF Transmitter Module Installation” on page 39 for detailed information. RS82 Remote Station Receiver UL listed. Refer to Instruction Manual for Remote Station Receiver Model RS82. + - Polarity Shown is Normal Standby + Power-limited (Dummy load with a 4.7K, ¼ watt resistor when no connection is made) Cutting TBL Jumper allows the reverse polarity circuit to open with a system trouble condition if no alarm condition exists. 4XTMF Transmitter Module Figure B.3 Remote Station Connection Using 4XTMF Module 128 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 NFPA Standard-Specific Requirements NFPA 72 Proprietary Protective Signaling Systems Fire Alarm Control Panel FACP Main Board Form-C Alarm contact programmed to activate on General Alarm. Form-C Trouble contact which will automatically activate on any Trouble condition. Form-C relay contact programmed to activate on Supervisory condition. Notes: 1. Connection between the MS-5UD/MS-10UD and the transmitter are supervised by the transmitter. 2. This MS-5UD/MS-10UD Transmitter arrangement can be employed for NFPA 72 Proprietary Protective Signaling System. 3. Potter Electric Model EFT-C has not been tested for UL 864 9th Edition and is for use in retrofit applications only. Figure B.4 Proprietary Protective Signaling System MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 129 NFPA Standard-Specific Requirements Central Station/Remote Station Transmitter: Connection to FACP Dry Contacts B.1 Central Station/Remote Station Transmitter: Connection to FACP Dry Contacts The dry contacts of the FACP programmable relays can be used to trip a UL-864 Listed Central Station/Remote Station Transmitter. The FACP contacts must be supervised by the Central Station/Remote Station Transmitter module using End-of-Line Resistors (ELRs) with a value determined by the Transmitter manufacturer. Power is also provided by the Central Station/Remote Station Transmitter manufacturer. Refer to the Central Station/Remote Station Transmitter manufacturer’s manual for details. Typical Central Station/Remote Station Transmitter Module Trouble* Superv. Alarm Typical Input Zone Triggers *Note: The Trouble Relay is a fail-safe relay. With power applied to the FACP and no troubles in the panel, the wiring should be connected to the NO and C contacts as indicated in the illustration. Fire Alarm Control Panel Figure B.5 FACP Dry Contacts Connection to Central Station/Remote Station Transmitter 130 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Appendix C: FACP with Keltron The following figure illustrates the connections between the FACP and Keltron Receiver/Transmitter. P ! CAUTION: POSSIBLE EQUIPMENT DAMAGE FOR REASONS OF WIRING DIAGRAM CLARITY, TERMINAL DESIGNATIONS OF KELTRON MODULES ARE NOT SHOWN IN ACTUAL ORDER. FOLLOW KELTRON MANUAL AND MODULE MARKINGS FOR EXACT TERMINAL LOCATIONS TO PREVENT SEVERE MODULE DAMAGE! IMPORTANT! All connections between the FACP and Keltron modules must be made within 20 feet and enclosed within conduit or equivalently protected against mechanical injury. Keltron 95M3158 TTM-RPS 1. Terminals 7 and 8: Remote station alarm/trouble inputs. 2. Terminals 9 and 10: Sprinkler supervisory input. UL-Listed UL-Listed *Note: For more information, refer to the Keltron manual. Sprinkler Supervisory Signal Alarm/Trouble Signal 4XTMF Module Note: Cut TBL jumper on 4XTMF module to send alarm/trouble signal from the same pair or terminals. Fire Alarm Control Panel (terminal blocks are not shown in their actual positions in order to clarify wiring connections) Figure C.1 Keltron Wiring MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 131 Appendix D: Wire Requirements Connecting external system accessories to the main circuits must be carefully considered to ensure proper operation. It is important to use the correct type of wire, gauge and run length for each circuit. Reference the chart below to specify wire requirements and limitations for each circuit. CIRCUIT CONNECTIONS Circuit Type WIRE REQUIREMENTS Initiating Device Circuit (power-limited) Connects to Initiating Devices Recommended Max. Distance Feet (meters) Wire Type and Limitations Circuit Function Untwisted, unshielded wire (maximum loop resistance not to exceed 100 ohms) ANN-BUS (EIA-485) Communication for Twisted pair a maximum power-limited ANN-BUS annunciator loop resistance of 120 and relay modules ohms ANN-BUS Power Power for ANN-BUS annunciators 24 VDC Regulated, resettable, nonresettable Power for accessories and 4-wire devices Auxiliary Trouble Input Open Collector trouble Single conductor input for CHG-75, CHG-120F, etc. Wire Gauge Distance limitation 12-18 AWG (3.25 - 0.75 mm2) set by 100 ohm resistance limitation 12-18 AWG (3.25 - 0.75 mm2) 6,000 (1,800 m) Refer to Table 2.1, “Wiring Distances,” on page 42 for information on device wiring Untwisted, unshielded wire Distance limitation set by 4 volt maximum line drop 12-18 AWG (3.25 - 0.75 mm2) Distance limitation 20 feet in same room 18 AWG (0.75 mm2) Remote Sync Output Provides strobe and normal sync for remote NAC power supplies Untwisted, unshielded pair wire Distance set by 295 12-18 AWG (3.25 - 0.75 mm2) ohm resistance limitation NAC Outputs Untwisted, unshielded pair wire Refer to Section D.1 and Section D.2 on page 133. Connects to NAC devices or Release devices Table D.1 FACP Wire Specifications D.1 MS-5UD-3(E) & MS-10UD-3(E) NAC Wiring The following table lists NAC wiring requirements for the MS-5UD-3(E) & MS-10UD-3(E) FACP which utilizes the FLPS-3 power supply. CLASS-B Max. allowable wire pair length (feet) CLASS-A Max. allowable wire pair length (feet) NAC Load (Amps) Max. allowable total loop resistance (ohms) AWG 12 solid AWG 14 solid AWG 16 solid AWG 18 solid AWG 12 solid AWG 14 solid AWG 16 solid AWG 18 solid 0.25 6.00 1554 977 613 386 777 489 307 193 0.5 3.00 777 489 307 193 389 244 153 97 0.75 2.00 518 326 204 129 259 163 102 64 1 1.50 389 244 153 97 194 122 77 48 1.25 1.20 311 195 123 77 155 98 61 39 32 1.5 1.00 259 163 102 64 130 81 51 1.75 0.86 222 140 88 55 111 70 44 28 2 0.75 194 122 77 48 97 61 38 24 2.25 0.67 173 109 68 43 86 54 34 21 2.5 0.60 155 98 61 39 78 49 31 19 Table D.2 NAC Wiring Requirements for FACP with FLPS-3 Power Supply NOTE: Calculations are based on Direct-Current Resistance data for uncoated copper wire, per National Electrical Code (2005 Edition) Table 8, Conductor Properties. 132 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 MS-5UD-7(C/E) & MS-10UD-7(C/E) NAC Wiring Wire Requirements NOTE: These distances reflect the worst case scenario and are based on the correct draw of the highest candela strobes at the low end of the supported NAC voltage with the entire load at the end of the circuit. Further distances can be achieved by performing a point to point voltage calculation that more accurately reflects the specific devices used and how they are dispersed on the circuit. D.2 MS-5UD-7(C/E) & MS-10UD-7(C/E) NAC Wiring The following table lists NAC wiring requirements for the MS-5UD-7(C/E) & MS-10UD-7(C/E) FACP which utilizes the FLPS-7 power supply. CLASS-B Max. allowable wire pair length (feet) NAC Load (Amps) Max. allowable total loop resistance (ohms) AWG 12 solid 0.25 6.00 1554 0.5 3.00 777 0.75 2.00 518 326 AWG 14 solid CLASS-A Max. allowable wire pair length (feet) AWG 16 solid AWG 18 solid AWG 12 solid AWG 14 solid AWG 16 solid AWG 18 solid 977 613 386 777 489 307 193 489 307 193 389 244 153 97 204 129 259 163 102 64 1 1.50 389 244 153 97 194 122 77 48 1.25 1.20 311 195 123 77 155 98 61 39 1.5 1.00 259 163 102 64 130 81 51 32 1.75 0.86 222 140 88 55 111 70 44 28 2 0.75 194 122 77 48 97 61 38 24 2.25 0.67 173 109 68 43 86 54 34 21 2.5 0.60 155 98 61 39 78 49 31 19 2.75 0.55 141 89 56 35 71 44 28 18 3 0.50 130 81 51 32 65 41 26 16 Table D.3 NAC Wiring Requirements for FACP with FLPS-7 Power Supply NOTE: Calculations are based on Direct-Current Resistance data for uncoated copper wire, per National Electrical Code (2005 Edition) Table 8, Conductor Properties. NOTE: These distances reflect the worst case scenario and are based on the correct draw of the highest candela strobes at the low end of the supported NAC voltage with the entire load at the end of the circuit. Further distances can be achieved by performing a point to point voltage calculation that more accurately reflects the specific devices used and how they are dispersed on the circuit. MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 133 Appendix E: Default Programming The following table provides a list of the programming options and their factory default settings. Program Option Factory Default Program Option Factory Default Zone #1-10 Enabled Zone #1-10 Type Zone #1-10 PAS Pre-Signal Enabled Zone #1-10 Verify Enabled Zone #1-10 ACC Message Zone #1-10 Freeze Enabled Adjective Noun NAC #1-4 Enabled NAC #1-4 Coding NAC #1-4 Auto Silence NAC #1-4 Silence Inhibit NAC #1-4 Silenceable Banner Relay 1 Relay 2 Relay 3 Trouble Reminder Canadian Option Charger Disable Factory Banner PAS Timer Pre-Signal Timer AC Loss Timer Waterflow Delay Timer Time Format Daylight Savings Enabled Daylight Savings Start Week Daylight Savings Start Month Daylight Savings End Week Daylight Savings End Month Printer Port Type Printer Supervision Printer Baud Rate Printer Parity Printer Data Bits Printer Stop Bits Printer Offline Timer ANN-BUS Enabled ANN-LED Piezo Enabled ANN-80 Piezo Enabled Yes Pull Station No Delay No No Message Active Yes None None Yes Steady No No Silenceable ANN-80 Lock Enabled ANN-80 Acknowledge Button Enabled ANN-80 Silence Button Enabled ANN-80 Reset Button Enabled ANN-80 Drill Button Enabled ACC All-Call Zone ANN-BUS Device 1 ANN-BUS Device 2 ANN-BUS Device 3 ANN-BUS Device 4 ANN-BUS Device 5 ANN-BUS Device 6 ANN-BUS Device 7 ANN-BUS Device 8 ANN-BUS Relay 1 type ANN-BUS Relay 2 type ANN-BUS Relay 3 type ANN-BUS Relay 4 type ANN-BUS Relay 5 type ANN-BUS Relay 6 type ANN-BUS Relay 7 type ANN-BUS Relay 8 type ANN-BUS Relay 9 type ANN-BUS Relay 10 type Phone Line 2 Supervision Primary Phone Type Secondary Phone Type Central Station Reporting Enabled Central Station Report Type Central Station Call Limit Central Station Primary Test Time Interval Central Station Primary Communication Format Central Station Primary Phone Number Central Station Primary Test Time Central Station Primary Account Code Central Station Secondary Test Time Interval Central Station Secondary Communication Format Central Station Secondary Phone Number Central Station Secondary Test Time Central Station Seocndary Account Code Service Terminal Ring Count Yes Yes Yes Yes Yes None None None None None None None None None Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Zone 9 Zone 10 Yes Touchtone Touchtone No First Available 0 24 Hr Ademco Contact ID 134 Alarm Trouble Supervisory No No No Factory Banner 120 120 2 0 12 Hour Yes Week 2 March Week 1 November Parallel Port No N/A N/A N/A N/A 60 No Yes Yes 1:00 0000 24 Hr Ademco Contact ID 2:00 0000 0 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Default Programming MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 135 Appendix F: Canadian Application F.1 ANN-LED Annunciator Installation for Canadian Applications • The FACP is supplied with a modified dress panel and one ANN-LED annunciator. • When installing and programming the FACP, the Canadian Option must be set to ON prior to any other panel programming (refer to “Canadian Option” on page 74 of the Programming Section of this manual). • If remote indicators are desired, they must be connected to the secondary ANN-BUS circuit. This requires the use of the ANN-SEC option card. • The installer must write in the Date of Final Assembly on the Master Marking and Warranty Label located on the FACP backbox door. • To comply with CAN/ULC-S559-04, the ANN-RLY option must be utilized along with the configuration shown in Figure F.2. Optional Secondary ANN-BUS using ANN-SEC Option Card. ANN-80C ANN-LED Annunciator on Primary ANN-BUS ANN-I/O FACP 510-annled.wmf ANN-LED ANN-S/PG ANN-RLY Figure F.1 Canadian FACP Configuration 136 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 ANN-LED Annunciator Installation for Canadian Applications Canadian Application To Remote Station Receiver + ALARM - + TROUBLE - + SUPERVISORY - C NC NO Relay 1 TB2 C NC NO Relay 2 TB2 C NC NO Relay 3 TB4 C NC NO Relay 4 TB4 C NC NO Relay 5 TB5 C NC NO Relay 6 TB5 ANN-RLY TB9 + 2 Non-resettable 1 Aux Power FACP Figure F.2 Alternate Transmission for Alarm, Trouble, and Supervisory Signals Notes: 1. Relays 1 and 2 on the ANN-RLY must be programmed for latching alarm activation. 2. Relays 3 and 4 on the ANN-RLY must be programmed for non-latching trouble activation. 3. Relays 5 and 6 on the ANN-RLY must be programmed for supervisory activation with latching/non-latching set in accordance with the local AHJ. 4. The ANN-RLY must be mounted inside the FACP cabinet. 5. Refer to the ANN-RLY Document #53033 for installation instructions. MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 137 Index Numerics 10 Zone Main Circuit Board 11 24 Hour Test Time 81 4XTMF 128 installation 39 see also Transmitter module 21, 39 5 Zone Main Circuit Board 10 A AC Loss Delay 71 AC power 28 AC power rating 15 AC power requirements 116 ACC audio message 63, 64 accessories 21 Account Code 81 ACK see also Acknowledge 15 Acknowledge 15 Acknowledge/Step 20, 96 Ademco contact ID format 120 Adjective list 64 multiple entries 65 Adjective/Noun 64, 65 alarm 99 piezo pulse rate 20 alarm relay 13, 33 contact rating 16 Alarm Silence 15, 20, 96 alarm verification 63, 102, 104 ANN-80(C) 46 ANN-BUS guidelines 41 ANN-I/O LED zone assignments 76 ANN-LED 53, 54, 56 ANN-RLY 54 ANN-SEC option card 40 applications 13 Autosilence 103 NAC 69 auxiliary power 33 Auxiliary Trouble Input 17 B backbox dimensions 21 mounting 26 Backup Reporting 80 138 Banner 70 setting 72 battery 21, 29 precautions 29 rating 16 battery box 22 mounting 27, 28 battery calculations 119 baud rate 92 BB-55F see also battery box 22 buttons see also control buttons 15 C cabinet mounting 26 CAC-5X 30 installation 37 call limit 58, 89 Canadian Applications 24 Canadian Option 70, 74 Central Station 80, 115 account code 81 communications 110 phone number 81 Phone Numbers 80 Central Station/Remote Station Reporting 126 charger capacity 16 Charger Disable 70 circuits 13 Class A 21, 30, 38 Class A Converter Module 21 installation 37 Class B 14, 16, 30 Clock Format 73 Coded Operation 102 coding NAC 67 two stage operation 67 combination circuit 31 combination waterflow/supervisory 31 requirements 31 wiring 31 communications format 82 compatibility see also device compatibility 13 contact ID 120 control buttons 15, 96 controls 20 current nonresettable power 33 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Index D–L resettable power 33 total output 32 current requirements for system 117, 118 D DACT onboard 79 Date setting 73 Daylight Savings Time 73 Default Programming 134 description 13 detector label 65 Detector adding description 64 enable/disable 62 device compatibility 13 dialer runaway 58, 89 Digital Communicator 23 dimensions backbox 21 Downloading 114, 115 dress panel 14, 22 Drill 15, 20, 96 E earth ground 28 edit detector screens 61 Enable/Disable zone 62 End-of-Line resistor IDC 16, 30, 31 NAC 16, 32 Enter key 60 Erase History 91 Error Checking 115 event code classification 121 event codes 82 exiting programming 59, 60 Read Status 59, 60 F fail-safe trouble relay 33 features 14 Form-C see also relay 13 freeze 30 freeze signal see also smoke detector monitoring 13 G guidelines 41 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 H Hazard Condition 100 History 90 erase 91 Maintenance Level 94 view events 90 I I3 detectors 30 IDC 14, 16, 30 alarm current 16 compatibility 30 End-of_Line resistor 31 End-of-Line resistor 16, 30 maximum loop resistance 16, 30 short circuit current 16 standby current 16 wiring 30 indicators 20 see also LED 15 Initiating Device Circuit 14, 16, 30 Class A 38 In-Line resistor IDC combination circuit 31 Input Zones 61, 105 installation 26 CAC-5X 37 Class A Converter Module 37 option modules 37 Transmitter Module 39 J J4 and J5 option module connectors 39 JP30 jumper placement supervision 39 K Key Panel 20 function keys 20 service/program keys 20 L lamp test 20 LCD display 15, 20 LED 15, 20 AC Power 15, 20, 96 Alarm Silence 15, 20 Alarm Silenced 97 Fire Alarm 15, 20, 97 Supervisory 15, 20, 97 System Trouble 20 Trouble 15, 97 Local Programming 58 139 M–P Index M O main circuit board see also 10 zone main circuit board 11 see also 5 Zone main circuit board 10 see also MS-10UD 11 maintenance 30 piezo pulse rate 20 Maintenance Alert 102 Maintenance Program Level 2 59, 93 maintenance signal see also smoke detector monitoring 13 Manual programming 58 Master Program Level 1 59, 61 Medical Alert 101 Mode key 60 mounting cabinet 26 main circuit board 26 municipal box 39 municipal box transmitter see also Transmitter module 21 Operating Instructions 96 Operation alarm 99 disable/enable 101 hazard condition 100 medical alert 101 normal 97 process monitor 100 supervisory 99 trouble 97 waterflow 101 Option Modules Printer/PC 92 option modules 21, 75 installation 37, 39 N NAC 13, 16, 66 Auto Silence 69 coded 102 coding 67 current 32 enable/disable 66 End-of-Line resistor 16, 32 maximum current 16 silence inhibit 69 silenceable 68 synchronized 68 wiring 32 NFPA 72 Auxiliary Fire Alarm System 125, 127 NFPA 72 Central Station Service (Protected Premises Unit) or Remote Station Service 125 NFPA 72 Proprietary Fire Alarm System 125 NFPA 72 Proprietary Protective Signaling Systems 129 NFPA 72 Remote Station Protective Signaling System 128 NFPA Standard 125 nonpower-limited wiring 35 nonresettable power 13, 17, 33 current 33 maximum current 17 Normal 97 normal display 58 Notification Appliance Circuit 13, 16, 32, 66 Class A 38 Noun list 65 multiple entries 65 140 P PAS 103 see also Positive Alarm Sequence 63 PAS timer 70 Password 60 change 92 Maintenance Level 2 60, 93 Master Level 1 60 Phone Number 81 piezo 20 alarm 20 maintenance 20 see also sounder 15 supervisory 20 trouble 20 polarity reversal circuit see also Transmitter module 40 Positive Alarm Sequence 63, 103 power 16, 28, 33 primary 28 secondary see also battery 29 power supply calculations 116 power-limited wiring 35 Power-up first time 59 Pre-signal 63 function 102 Pre-signal Delay timer 71 Pre-signal timer 70 Primary Phone 79 printer baud rate 92 Process Monitor 100 Program clear 92 program keys see also Key Panel 20 Programming 59 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Index R–T autoprogramming 58 exiting 59 factory default 134 Level 1 59 Level 2 59 manual 58 Master Level 1 61 Programming Levels 59 Programming Screens 59 Proprietary Yes see also Remote Upload 114 PS-Tools 23, 113 R Read Status 59, 105 annunciators 108, 109 exiting 59 history 107 input zones 105 NAC 106 Print 107 relay 106 Real-Time Clock 102 Recall/Increment Function 65 Receivers 112 relay 13, 21, 33, 69 contact rating 16, 33 Form-C 69 programming 69 Remote Download 113 Remote Programming 58 remote station service 40 REN see also Ringer Equivalence Number 23 Reporting Enable 80 Reset 15, 20, 96 resettable power 13, 16, 33 current 33 maximum current 16 reverse polarity circuit see also Transmitter module 21 Ring Count 89 Ringer Equivalence Number 23 ROME Series 55 rules for ANN-BUS wiring 41 S secondary ANN-BUS 40 Secondary Phone 80 Secret Code 115 Security Features 114 Service Terminal 89 Silence Inhibit 69, 103 Silenceable NAC 68 silenceable circuits MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 synchronized signals 68 sounder 15, 20 strobes 15, 68 Style B 16, 30 see also Class B 14 Style D 21, 30, 38 Style Y 16 see also Class B 14 Style Z 21, 38 subscreen 60 supervision Transmitter option module placement 39 supervisory 13, 99 piezo pulse rate 20 supervisory relay 33 contact rating 16 synchronization 68 synchronized 68 synchronized signals 68 and silenceable circuits 68 system current calculations 117 System Setup 69 T Telephone Circuitry 23 Telephone Company Rights and Warnings 24 telephone line 36 Terminal 89 Test Time Interval 81 Time setting 73 Time-Date Maintenance Level 95 Time-Date setting 70, 72 Time-out 115 Timers 69 Transmittal Priorities 111 transmitter module 21, 39 operation 39 specifications 40 Transmitter option module placement supervision 39 Trouble 97 trouble piezo pulse rate 20 trouble call limit 58, 89 Trouble Input Auxiliary 17 trouble relay 13, 33 contact rating 16 fail-safe 33 Trouble Reminder 70, 103 two stage operation 67 Type zone 62 141 U–Z Index U UL wiring requirements 35 Upload/Download 113 V Verification zone 63 View Events 90 W Walktest 91 audible 91 Maintenance Level 94 operation 104 silent 91 Waterflow Delay timer 70, 71 Waterflow Retard Timer 104 Wire Requirements 132 wiring CAC-5X 38 Class A Converter Module 38 Class A IDC 38 Class A NAC 38 combination waterflow/supervisory 31 IDC 30 NAC 32 nonpower-limited 35 power-limited 35 UL requirements 35 Z Zone type 62 verification 63 Zone Setup Maintenance Level 93 142 MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 Manufacturer Warranties and Limitation of Liability Manufacturer Warranties. Subject to the limitations set forth herein, Manufacturer warrants that the Products manufactured by it in its Northford, Connecticut facility and sold by it to its authorized Distributors shall be free, under normal use and service, from defects in material and workmanship for a period of thirty six months (36) months from the date of manufacture (effective Jan. 1, 2009). The Products manufactured and sold by Manufacturer are date stamped at the time of production. Manufacturer does not warrant Products that are not manufactured by it in its Northford, Connecticut facility but assigns to its Distributor, to the extent possible, any warranty offered by the manufacturer of such product. This warranty shall be void if a Product is altered, serviced or repaired by anyone other than Manufacturer or its authorized Distributors. This warranty shall also be void if there is a failure to maintain the Products and the systems in which they operate in proper working conditions. MANUFACTURER MAKES NO FURTHER WARRANTIES, AND DISCLAIMS ANY AND ALL OTHER WARRANTIES, EITHER EXPRESSED OR IMPLIED, WITH RESPECT TO THE PRODUCTS, TRADEMARKS, PROGRAMS AND SERVICES RENDERED BY MANUFACTURER INCLUDING WITHOUT LIMITATION, INFRINGEMENT, TITLE, MERCHANTABILITY, OR FITNESS FOR ANY PARTICULAR PURPOSE. MANUFACTURER SHALL NOT BE LIABLE FOR ANY PERSONAL INJURY OR DEATH WHICH MAY ARISE IN THE COURSE OF, OR AS A RESULT OF, PERSONAL, COMMERCIAL OR INDUSTRIAL USES OF ITS PRODUCTS. This document constitutes the only warranty made by Manufacturer with respect to its products and replaces all previous warranties and is the only warranty made by Manufacturer. No increase or alteration, written or verbal, of the obligation of this warranty is authorized. Manufacturer does not represent that its products will prevent any loss by fire or otherwise. Warranty Claims. Manufacturer shall replace or repair, at Manufacturer's discretion, each part returned by its authorized Distributor and acknowledged by Manufacturer to be defective, provided that such part shall have been returned to Manufacturer with all charges prepaid and the authorized Distributor has completed Manufacturer's Return Material Authorization form. The replacement part shall come from Manufacturer's stock and may be new or refurbished. THE FOREGOING IS DISTRIBUTOR'S SOLE AND EXCLUSIVE REMEDY IN THE EVENT OF A WARRANTY CLAIM. Warn-HL-08-2009.fm MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014 143 World Headquarters 1 Firelite Place Northford, CT 06472-1653 USA 203-484-7161 fax 203-484-7118 www.firelite.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V4.4 (128-bit) User Access : Print, Copy, Extract, Print high-res Author : E654944 Create Date : 2014:03:07 11:35:35Z Modify Date : 2014:03:20 08:01:40-04:00 XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Producer : Acrobat Distiller 9.0.0 (Windows) Creator Tool : FrameMaker 11.0.2 Metadata Date : 2014:03:20 08:01:40-04:00 Format : application/pdf Title : 52626.book Creator : E654944 Document ID : uuid:7694d397-b2b8-4f1d-be07-2ac8f742528a Instance ID : uuid:a6d1edfd-b5ea-4941-941e-6d8d0008f754 Page Mode : UseOutlines Page Count : 144EXIF Metadata provided by EXIF.tools