Lsi Sas3041E Users Manual PCI Express To 3.0 Gbit/s Serial Attached SCSI (SAS) Host Adapters User’s Guide

860-0477-001 860-0477-001

SAS3041E to the manual dad56017-51a0-4caa-8304-4075431b4ee9

2015-02-09

: Lsi Lsi-Sas3041E-Users-Manual-576179 lsi-sas3041e-users-manual-576179 lsi pdf

Open the PDF directly: View PDF PDF.
Page Count: 46

DownloadLsi Lsi-Sas3041E-Users-Manual- PCI Express To 3.0 Gbit/s Serial Attached SCSI (SAS) Host Adapters User’s Guide  Lsi-sas3041e-users-manual
Open PDF In BrowserView PDF
USER’S
GUIDE

PCI Express to 3.0 Gbit/s
Serial Attached SCSI
(SAS) Host Adapters
Model Numbers:
LSISAS3041E, LSISAS3041EL
LSISAS3080E, LSISAS3080EL
LSISAS3081E, LSISAS3081EL
LSISAS3442E, LSISAS3442EL
LSISAS3443E, LSISAS3443EL
LSISAS3444E, LSISAS3444EL
LSISAS3800E
LSISAS3801E, LSISAS3801EL

August 2006
Version 1.0

®

DB15-000363-00

Electromagnetic Compatibility Notices
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1.
2.

This device may not cause harmful interference, and
This device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:

•
•
•
•

Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.

Shielded cables for SCSI connection external to the cabinet are used in the compliance testing of this Product.
LSI Logic is not responsible for any radio or television interference caused by unauthorized modification of this
equipment or the substitution or attachment of connecting cables and equipment other than those specified by
LSI Logic. The correction of interferences caused by such unauthorized modification, substitution, or attachment will
be the responsibility of the user.
The LSI Logic PCI Express to 3.0 Gbit/s SAS host adapters (LSISAS3041E, LSISAS3041EL, LSISAS3080E,
LSISAS3080EL, LSISAS3081E, LSISAS3081EL, LSISAS3442E, LSISAS3442EL, LSISAS3443E, LSISAS3443EL,
LSISAS3444E, LSISAS3444EL, LSISAS3800E, LSISAS3801E, and LSISAS3801EL) are tested to comply with FCC
standards for home or office use.
This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du
Canada.

This is a Class B product based on the standard of the Voluntary Control Council for Interference from Information
Technology Equipment (VCCI). If this is used near a radio or television receiver in a domestic environment, it may
cause radio interference. Install and use the equipment according to the instruction manual.

LSI Logic Asia, Inc. Taiwan Branch
10/F, 156, Min Sheng E. Rd., Section 3,
Taipei, Taiwan, R.O.C.
Tel: 886.2.2718.7828
FAX: 886.2.2718.8869

ii
Copyright © 2006 by LSI Logic Corporation. All rights reserved.

LSI Logic Corporation
North American Headquarters
Milpitas, CA
Tel: 408.433.8000

This document is preliminary. As such, it contains data derived from functional
simulations and performance estimates. LSI Logic has not verified either the
functional descriptions, or the electrical and mechanical specifications using
production parts.
This document contains proprietary information of LSI Logic Corporation. The
information contained herein is not to be used by or disclosed to third parties
without the express written permission of an officer of LSI Logic Corporation.
LSI Logic products are not intended for use in life-support appliances, devices,
or systems. Use of any LSI Logic product in such applications without written
consent of the appropriate LSI Logic officer is prohibited.
Document DB15-000363-00, Version 1.0, August 2006
This document describes the LSI Logic Corporation LSISAS3041E,
LSISAS3041EL, LSISAS3080E, LSISAS3080EL, LSISAS3081E, LSISAS3081EL,
LSISAS3442E, LSISAS3442EL, LSISAS3443E, LSISAS3443EL, LSISAS3444E,
LSISAS3444EL, LSISAS3800E, LSISAS3801E, and LSISAS3801EL PCI
Express to 3.0 Gbit/s SAS host adapters and will remain the official reference
source for all revisions/releases of these products until rescinded by an update.
LSI Logic Corporation reserves the right to make changes to any products herein
at any time without notice. LSI Logic does not assume any responsibility or
liability arising out of the application or use of any product described herein,
except as expressly agreed to in writing by LSI Logic; nor does the purchase or
use of a product from LSI Logic convey a license under any patent rights,
copyrights, trademark rights, or any other of the intellectual property rights of
LSI Logic or third parties.
Copyright © 2006 by LSI Logic Corporation. All rights reserved.
TRADEMARK ACKNOWLEDGMENT
LSI Logic, the LSI Logic logo design and Fusion-MPT are trademarks or
registered trademarks of LSI Logic Corporation. Windows and Windows NT are
registered trademarks of Microsoft Corporation. All other brand and product
names may be trademarks of their respective companies.
DB
To receive product literature, visit us at http://www.lsilogic.com.
For a current list of our distributors, sales offices, and design resource
centers, view our web page located at
http://www.lsilogic.com/contacts/index.html

iii
Copyright © 2006 by LSI Logic Corporation. All rights reserved.

iv
Copyright © 2006 by LSI Logic Corporation. All rights reserved.

Preface

This document is the user’s guide for the LSI Logic PCI Express to
3.0 Gbit/s SAS host adapters, referred to as LSI PCIe to SAS host
adapters. It contains a functional description of the LSI PCIe to SAS host
adapters as well as physical and electrical specifications. It also contains
instructions for installing the host adapters and for connecting SAS
devices.

Audience
This document assumes that you have some familiarity with Serial
Attached SCSI (SAS) devices and PCI Express devices. This document
benefits people installing and using the LSI PCIe to SAS host adapter.

Organization
This document has the following chapters:

•

Chapter 1, Introduction, describes the LSI PCIe to SAS host
adapters.

•

Chapter 2, Hardware Installation, describes how to install the LSI
PCIe to SAS host adapters in a system.

•

Chapter 3, Host Adapter Characteristics, provides the
environmental and electrical specifications for the LSI PCIe to SAS
host adapters. This chapter also provides the mechanical drawings
and connector locations for the LSI PCIe to SAS host adapters.

PCIe to 3.0 Gbit/s SAS Host Adapters User’s Guide
Copyright © 2006 by LSI Logic Corporation. All rights reserved.

v

Related Publications
LSI Logic Documents
LSISAS1064E PCI Express to 4-Port Serial Attached SCSI Controller
Technical Manual, Document No. DB14-000331-02
LSISAS1068E PCI Express to 8-Port Serial Attached SCSI Controller
Technical Manual, Document No. DB14-000330-02
Fusion-MPT™ Device Management User’s Guide, Document No.
DB15-000186-01
Integrated RAID User’s Guide, Document No. DB15-000292-00
Integrated RAID for SAS User’s Guide, Document No. DB15-000357-00
LSI Logic World Wide Web Home Page
www.lsilogic.com
ANSI
11 West 42nd Street
New York, NY 10036
(212) 642-4900
InterNational Committee on Information Technology Standards
(INCITIS) T10 Technical Committee
http://www.t10.org
Global Engineering Documents
15 Inverness Way East
Englewood, CO 80112
(800) 854-7179 or (303) 397-7956 (outside U.S.); FAX (303) 397-2740
PCI Special Interest Group
2575 N. E. Katherine
Hillsboro, OR 97214
(800) 433-5177; (503) 693-6232 (International); FAX (503) 693-8344

vi

Preface
Copyright © 2006 by LSI Logic Corporation. All rights reserved.

Revision Record
Version

Date

1.0

8/2006

Remarks
This release provides information about the LSISAS3041E, LSISAS3041EL,
LSISAS3080E, LSISAS3080EL, LSISAS3081E, LSISAS3081EL, LSISAS3442E,
LSISAS3442EL, LSISAS3443E, LSISAS3443EL, LSISAS3444E,
LSISAS3444EL, LSISAS3800E, LSISAS3801E, and LSISAS3801EL PCI
Express to 3.0 Gbit/s SAS host adapters. Several of these host adapters were
previously featured in the 3 Gbit/s Serial Attached SCSI Host Adapters User’s
Guide (March 2006, Version 2.0).

Preface
Copyright © 2006 by LSI Logic Corporation. All rights reserved.

vii

viii

Preface
Copyright © 2006 by LSI Logic Corporation. All rights reserved.

Contents

Chapter 1
Introduction
1.1
1.2
1.3
1.4

Overview
Features
PCI Performance
1.3.1
PCI Express Features
Software

1-1
1-3
1-4
1-4
1-6

Chapter 2
Hardware Installation
2.1
2.2

Quick Installation Instructions
Detailed Installation Instructions

2-1
2-2

Chapter 3
Host Adapter Characteristics
3.1
Characteristics of the LSI PCIe to SAS Host Adapters
3-1
3.1.1
LSISAS3041E and LSISAS3041EL Host Adapters
Characteristics
3-2
3.1.2
LSISAS3080E and LSISAS3080EL Host Adapters
Characteristics
3-4
3.1.3
LSISAS3081E and LSISAS3081EL Host Adapters
Characteristics
3-6
3.1.4
LSISAS3442E and LSISAS3442EL Host Adapters
Characteristics
3-8
3.1.5
LSISAS3443E and LSISAS3443EL Host Adapters
Characteristics
3-10
3.1.6
LSISAS3444E and LSISAS3444EL Host Adapters
Characteristics
3-12
3.1.7
LSISAS3800E Host Adapter Characteristics
3-14

Contents
Version 1.0

ix
Copyright © 2006 by LSI Logic Corporation. All rights reserved.

3.1.8
3.2

LSISAS3801E and LSISAS3801EL Host Adapters
Characteristics
Electrical and Environmental Specifications
3.2.1
Electrical Characteristics
3.2.2
Thermal and Atmospheric Characteristics
3.2.3
Safety Characteristics

Customer Feedback

x

Contents
Version 1.0

Copyright © 2006 by LSI Logic Corporation. All rights reserved.

3-16
3-18
3-18
3-19
3-19

Figures
2.1
3.1
3.2
3.3
3.4
3.5
3.6
3.7
3.8

Installing an LSI PCIe to SAS x8 Host Adapter in a
PCI Express Slot
LSISAS3041E and LSISAS3041EL Board Layout
LSISAS3080E and LSISAS3080EL Board Layout
LSISAS3081E and LSISAS3081EL Board Layout
LSISAS3442E and LSISAS3442EL Board Layout
LSISAS3443E and LSISAS3443EL Board Layout
LSISAS3444E and LSISAS3444EL Board Layout
LSISAS3800E Board Layout
LSISAS3801E and LSISAS3801EL Board Layout

Contents
Version 1.0

2-3
3-3
3-5
3-7
3-9
3-11
3-13
3-15
3-17

xi
Copyright © 2006 by LSI Logic Corporation. All rights reserved.

xii

Contents
Version 1.0

Copyright © 2006 by LSI Logic Corporation. All rights reserved.

Tables
1.1
1.2
1.3
3.1

LSI PCIe to SAS Host Adapters and Controllers
SAS Bandwidths
Software Support
Maximum Power Requirements

Contents
Version 1.0

1-2
1-3
1-6
3-18

xiii
Copyright © 2006 by LSI Logic Corporation. All rights reserved.

xiv

Contents
Version 1.0

Copyright © 2006 by LSI Logic Corporation. All rights reserved.

Chapter 1
Introduction

This chapter describes the LSI Logic PCI Express to 3.0 Gbit/s SAS host
adapters and consists of the following sections:

1.1

•

Section 1.1, “Overview”

•

Section 1.2, “Features”

•

Section 1.3, “PCI Performance”

•

Section 1.4, “Software”

Overview
The LSI PCIe to SAS host adapters provide four or eight serial ports for
connection to SAS/SATA (Serial ATA) devices. Each port is capable of
3.0 Gbit/s SAS link rates and 3.0 Gbit/s SATA link rates. The PCI Express
transmission and reception data rate is 2.5 Gbits/s in each direction,
yielding a total bandwidth of 5.0 Gbits/s for each full-duplex lane. The LSI
PCIe to SAS host adapters are implemented using four or eight PCI
Express phys, which provide possible host-side maximum transmission
and reception rates of up to 4.0 Gbytes/s.
The LSI PCIe to SAS host adapters contain Flash ROM for storing the
BIOS and firmware, and NVSRAM for storing nonvolatile RAID
information. The LSISAS3442E, LSISAS3442EL, LSISAS3443E,
LSISAS3443EL, LSISAS3444E, LSISAS3444EL, LSISAS3800E,
LSISAS3801E, and LSISAS3801EL host adapters provide a 128 K x
36-bit PBSRAM memory device for storing SAS Address Port information
allowing for connection to more than 128 devices. The LEDs on the host
adapters report a heartbeat, activity, and fault conditions when detected
by firmware. Fusion-MPT™ firmware operates the host adapter.

PCIe to 3.0 Gbit/s SAS Host Adapters User’s Guide
Version 1.0

Copyright © 2006 by LSI Logic Corporation. All rights reserved.

1-1

The PCI Express interface is compliant with the PCI Express
Specification, revision 1.0a. All PCI software is backwards compliant with
previous versions of the PCI/PCI-X specifications. The LSI PCIe to SAS
products implement the PCI Express interface as a x4 or x8 interface.
The LSI PCIe to SAS host adapters use either a standard PCI or a lowprofile PCI bracket type. The LSI PCIe to SAS host adapter SAS
interface is compatible with the ANSI Serial Attached SCSI Specification,
revision 1.0 and the Serial ATA Specification, revision 1.0a.
The functionality of LSI PCIe to SAS host adapters come from either the
LSISAS1064E controller chip or the LSISAS1068E controller chips. The
LSISAS1064E integrates four high-performance SAS/SATA phys and the
LSISAS1068E integrates eight high-performance SAS/SATA phys. The
design of LSI PCIe to SAS host adapters makes it easy to add SAS
interfaces to any computer, workstation, or server with a PCI Express
bus.
Table 1.1 shows the LSI PCIe to SAS controllers and their associated
host adapters that support SAS/SATA devices. All board numbers contain
an “E” after the numeric portion of their name, indicating that they use
the PCI Express bus. Boards without an “L” after the numbers in their
name use a standard PCI bracket type. Boards with an “L” after the
numbers in their name use a low-profile PCI bracket type.
Table 1.1

1-2

LSI PCIe to SAS Host Adapters and Controllers

Controllers

LSI PCIe to SAS Host Adapters

LSISAS1064E

LSISAS3041E, LSISAS3041EL

LSISAS1068E

LSISAS3080E, LSISAS3080EL,
LSISAS3081EL, LSISAS3442E,
LSISAS3443E, LSISAS3443EL,
LSISAS3444EL, LSISAS3800E,
LSISAS3801E

LSISAS3081E,
LSISAS3442EL,
LSISAS3444E,
LSISAS3801E,

Introduction
Version 1.0

Copyright © 2006 by LSI Logic Corporation. All rights reserved.

1.2

Features
This section lists features of the LSI PCIe to SAS host adapters:

•

Supports narrow port and wide port as shown in Table 1.2.

Table 1.2

SAS Bandwidths

Half Duplex

Full Duplex

Narrow Port (1 Lane)—300 Mbytes/s

Narrow Port (1 Lane)—600 Mbytes/s

Wide Port (2 Lanes)—600 Mbytes/s

Wide Port (2 Lanes)—1200 Mbytes/s

Wide Port (4 Lanes)—1200 Mbytes/s

Wide Port (4 Lanes)—2400 Mbytes/s

•

Supports SSP, STP, and SMP as defined in the Serial Attached SCSI
(SAS) Specification, version 1.0.

•

Supports SATA as defined in the Serial ATA Specification, version
1.0a.

•

Provides configurable drive spin-up sequencing on a per-phy basis.

•

Simplifies cabling with a point-to-point, serial architecture.

•

Provides smaller and thinner cables that do not restrict airflow.

•

Provides a serial, point-to-point, enterprise-level storage interface.

•

Transfers data using SCSI information units.

•

Provides two LEDs for each phy to indicate link activity and faults for
the LSISAS3041E, LSISAS3041EL, LSISAS3080E, LSISAS3080EL,
LSISAS3081E, LSISAS3081EL, LSISAS3442E, LSISAS3442EL,
LSISAS3443E, LSISAS3443EL, LSISAS3444E, LSISAS3444EL,
LSISAS3800E, LSISAS3801E, and LSISAS3801EL host board
adapters (HBAs).

•

Provides two light pipes routed through the PCI bracket for the
LSISAS3041E, LSISAS3041EL, LSISAS3080E, LSISAS3080EL,
LSISAS3081E, LSISAS3081EL, LSISAS3442E, LSISAS3442EL,
LSISAS3443E, LSISAS3443EL, LSISAS3444E, LSISAS3444EL, and
LSISAS3800E host adapters. One light pipe indicates activity on any
phy. The other light pipe indicates a heartbeat or a fault condition.
The LSISAS3801E and LSISAS3801EL use two LEDs routed
through the PCI bracket for the same purpose.

•

Provides compatibility with SATA target devices.

Features
Version 1.0

1-3
Copyright © 2006 by LSI Logic Corporation. All rights reserved.

1.3

PCI Performance
LSI PCIe to SAS host adapter boards support the PCI Express interface.
The following lists are of their features.

1.3.1

PCI Express Features
The PCI Express features of the LSI PCIe to SAS host adapters include:

•

Provides four (boards using LSISAS1064E) or eight (boards using
LSISAS1068E) PCI Express phys

•

Supports a single-phy (1 lane) link transfer rate up to 2.5 Gbits/s in
each direction

•

Supports x8, x4, and x1 link widths

•

Automatically downshifts to a x4 link width if plugged into a x4
connector or into a x8 connector that is wired as a x4 connector

•

Provides a scalable interface

•

1-4

–

Single-lane aggregate bandwidth of up to 0.5 Gbytes/s
(500 Mbytes/s)

–

Quad-lane aggregate bandwidth of up to 2.0 Gbytes/s
(2000 Mbytes/s)

–

8-lane aggregate bandwidth of up to 4.0 Gbytes/s
(4000 Mbytes/s)

Supports serial, point-to-point interconnections between devices
–

Reduces the electrical load of the connection

–

Enables higher transmission and reception frequencies

•

Supports lane reversal and polarity inversion

•

Supports PCI Express Hot Plug

•

Supports Power Management
–

Supports PCI Power Management 1.2

–

Supports Active State Power Management (ASPM), including the
L0, L0s, L1 states, by placing links in a power-savings mode
during times of no link activity

Introduction
Version 1.0

Copyright © 2006 by LSI Logic Corporation. All rights reserved.

•

Contains a replay buffer that preserves a copy of the data for
retransmission in case a CRC error occurs

•

Supports the PCI Express Advanced Error Reporting capabilities

•

Uses a packetized and layered architecture

•

Achieves a high bandwidth per pin with low overhead and low latency

•

PCI Express is software compatible with PCI and PCI-X software
–

Leverages existing PCI device drivers

–

Supports the Memory, I/O, and Configuration address spaces

–

Supports memory read/write transactions, I/O read/write
transactions, and configuration read/write transactions

•

Provides 4 Kbytes of PCI Configuration address space per device

•

Supports posted and non-posted transactions

•

Provides quality of service (QOS) link configuration and arbitration
policies

•

Supports Traffic Class 0 and one virtual channel

•

Supports Message Signaled Interrupts (both MSI and MSI-X) as well
as INTx interrupt signaling for legacy PCI support

•

Supports end-to-end CRC (ECRC) and Advanced Error Reporting

PCI Performance
Version 1.0

1-5
Copyright © 2006 by LSI Logic Corporation. All rights reserved.

1.4

Software
The LSI PCIe to SAS host adapters support all major operating systems,
as shown in Table 1.3.
Table 1.3

Software Support

OS Support

Versions

Windows

XP, 2000, Server 2003 32-bit and 64-bit
(x86, AMD, and IA-64)

Linux: Red Hat Enterprise Linux (RHEL) 3 and 4
Linux: SuSE Enterprise Server

(SLES) 8 and 9

Novel NetWare

5.1 and 6.5

Sun Sparc Solaris

2.6, 2.7, 2.8, 2.9, and 2.10

Utilities

Install, Flash and BIOS Configuration Utility

The LSI PCIe to SAS host adapters use the Fusion-MPT architecture for
all major operating systems, which allows for thinner drivers for better
performance. To obtain a device driver that supports your operating
system, contact the LSI Technical Support team at 719-533-7230 or visit
our web site at http://www.lsilogic.com.

1-6

Introduction
Version 1.0

Copyright © 2006 by LSI Logic Corporation. All rights reserved.

Chapter 2
Hardware Installation

This chapter provides both quick instructions and detailed instructions on
how to install the LSI PCIe to 3.0 Gbit/s SAS host adapter. This chapter
consists of the following sections:

2.1

•

Section 2.1, “Quick Installation Instructions”

•

Section 2.2, “Detailed Installation Instructions”

Quick Installation Instructions
The following steps summarizes the installation instructions.
Use these instructions to install your LSI PCIe to SAS host adapter if you
are comfortable with the installation procedure. Section 2.2, “Detailed
Installation Instructions” provides detailed installation instructions.
Step 1.

Unpack the host adapter and inspect it for damage.

Step 2.

Turn off the system and remove the power cord(s).

Step 3.

Remove the cover from the system.

Step 4.

Insert the host adapter in an available PCI Express slot.

Step 5.

Secure the bracket to the system’s chassis.

Step 6.

Connect the serial cable(s) between the host adapter and the
serial hard disk drive(s). Figure 2.1 illustrates the locations of
the connectors on your host adapter.

Step 7.

Replace the cover and the power cord(s), then power-up the
system.

LSI PCIe to SAS host adapter hardware installation is complete.

PCIe to 3.0 Gbit/s SAS Host Adapters User’s Guide
Version 1.0

Copyright © 2006 by LSI Logic Corporation. All rights reserved.

2-1

2.2

Detailed Installation Instructions
The following steps provide detailed installation instructions:
Step 1.

Unpack the host adapter and inspect it for damage.
Unpack the host adapter in a static-free environment. Remove
the host adapter from the anti-static bag and inspect it for
damage. Contact LSI or your OEM support representative if the
host adapter appears damaged.

Step 2.

Turn off the system and disconnect the power cord(s).
Turn off the system’s power and physically remove the power
cord(s) from the system.

Step 3.

Remove the cover from the system.
Remove the cover from the system’s chassis. Disconnect the
system from any networks.

Step 4.

Insert the host adapter in an available PCI Express slot.
Locate an empty PCI Express slot. Remove the blank bracket
panel on the back of the computer that is aligned with the PCI
Express slot you have selected. Save the bracket screw when
present.
Align the host adapter to a PCI Express slot. Press down gently
but firmly to properly seat the host adapter in the slot.
Figure 2.1 illustrates how to insert the host adapter in a PCI
Express slot.

Step 5.

Secure the bracket to the system’s chassis.
Install the bracket screw, when present, or engage the system’s
retention mechanism to secure the host adapter to the system’s
chassis.

Step 6.

Connect the serial cable(s) between the host adapter and the
serial hard disk drive(s) (HDD). Figure 2.1 illustrates the
locations of the connectors on your host adapter.

Step 7.

Replace the cover and the power cord(s), then power-up the
system.
Replace the system’s cover, reconnect the power cord(s) and
any network cables. Turn power on to the system.

2-2

Hardware Installation
Version 1.0

Copyright © 2006 by LSI Logic Corporation. All rights reserved.

LSI PCIe to SAS host adapter hardware installation is complete.
Figure 2.1

Installing an LSI PCIe to SAS x8 Host Adapter in a
PCI Express Slot

HDD
Connector

Bracket
Screw

Serial Signal
Cables
Press Here

HBA to HDD
Breakout Cable
Press Here

4 Lane Internal
HBA Connector
SFF-8484

4 Lane
External
PCB
Receptacle
and Cable
with
Jackscrews
SFF-8470

32-bit Slots
(3.3 V)
Edge of
Host Board

PCI Express x8 Slot

64-bit Slots
(3.3 V)

Note:

The HBA shape, size, and locations of components on your
x8 (or x4) HBA and its bracket may vary from this
illustration. A PCI Express connector is smaller than a
PCI/PCI-X connector.

Detailed Installation Instructions
Version 1.0

Copyright © 2006 by LSI Logic Corporation. All rights reserved.

2-3

2-4

Hardware Installation
Version 1.0

Copyright © 2006 by LSI Logic Corporation. All rights reserved.

Chapter 3
Host Adapter Characteristics

This chapter describes the characteristics of the LSI PCIe to 3.0 Gbit/s
SAS host adapters. The chapter includes these topics:

3.1

•

Section 3.1, “Characteristics of the LSI PCIe to SAS Host Adapters”

•

Section 3.2, “Electrical and Environmental Specifications”

Characteristics of the LSI PCIe to SAS Host Adapters
The LSI PCIe to SAS host adapters use either the LSISAS1064E
controller or the LSISAS1068E controller. The LSISAS1064E controller
connects up to four SAS/SATA devices to a computer system through the
PCI Express interface. The LSISAS1068E controller connects up to eight
SAS/SATA devices to a computer system through the PCI Express
interface. The LSI controllers are implemented using either four
(LSISAS1064E) or eight (LSISAS1068E) PCI Express phys. Each phy
operates at 2.5 Gbits/s which provide possible host-side maximum
transmission and reception rates of up to 4.0 Gbytes/s.
The LSISAS1064E and the LSISAS1068E controller chips contain the
PCI Express functionality for the LSI PCIe to SAS host adapters. The
controller chip connects directly to the PCI Express bus and generates
timing and protocol in compliance with the PCI Express specification.
The LSISAS1064E and the LSISAS1068E controller chips contain the
SAS/SATA functionality for the LSI PCIe to SAS host adapters. The
controller chips connect channels directly to the SAS/SATA devices.
The LSI PCIe to SAS host adapters provide a 2M x 8-bit Flash ROM for
storing the BIOS and firmware. The LSI PCIe to SAS host adapters
provide up to 32 K x 8-bit NVSRAM for storing the nonvolatile RAID
information when a system failure happens. The LSISAS3442E,

PCIe to 3.0 Gbit/s SAS Host Adapters User’s Guide
Version 1.0

Copyright © 2006 by LSI Logic Corporation. All rights reserved.

3-1

LSISAS3442EL, LSISAS3443E, LSISAS3443EL, LSISAS3444E,
LSISAS3444EL, LSISAS3800E, LSISAS3801E, and LSISAS3801EL
host adapters provide a 128 K x 36-bit PBSRAM memory device for
storing SAS Address Port information allowing for connection to more
than 128 devices.

3.1.1

LSISAS3041E and LSISAS3041EL Host Adapters Characteristics
The LSISAS3041E and LSISAS3041EL are the same HBA with the
exception of the PCI bracket. The LSISAS3041E uses a standard PCI
bracket and the LSISAS3041EL uses the low-profile (LPPCI) PCI
bracket. Figure 3.1 shows the HBAs and their brackets.

3.1.1.1

LEDs
The LSISAS3041E and LSISAS3041EL host adapters have four LEDs,
labeled A0–A3, that turn green to indicate an activity condition on any of
the eight phys. There are eight LEDs, labeled LNP0–LNP3, that turn
yellow to indicate a fault condition on any of the eight phys. See
Figure 3.1 for LED locations.
The LSISAS3041E and LSISAS3041EL host adapters have two light
pipes routed through the PCI bracket. One light pipe turns green to
indicate activity on any phy. The other light pipe is bi-color. It flashes
green to indicate the LSISAS1064E heartbeat, or it turns yellow when the
LSISAS1064E firmware detects a fault condition.

3.1.1.2

Connectors
This section provides a description of the five different connectors on the
LSISAS3041E and LSISAS3041EL host adapters. See Figure 3.1 for
connector locations.
PCI Express Connector (J1) – The PCI Express interface has four PCI
Express phys, which provide possible host-side maximum transmission
and reception rates of up to 2.0 Gbytes/s. The PCI Express connection
is made through the edge connector J1. The signal definitions and pin
numbers conform to the PCI Express specifications.
SAS/SATA Connectors (J2, J5–J7) – The LSISAS3041E supports
SAS/SATA connections through connectors J2, J5, J6, and J7. These
connectors are SATA internal right-angle connectors.

3-2

Host Adapter Characteristics
Version 1.0

Copyright © 2006 by LSI Logic Corporation. All rights reserved.

Activity LED Header (J3) – 4-pin, right angle, 0.1-inch pitch, pin header
for driving external activity LEDs.
Figure 3.1

LSISAS3041E and LSISAS3041EL Board Layout

LSISAS3041E
Standard PCI Bracket
LSISAS3041EL
Low-Profile
(LPPCI)
PCI Bracket
Port 3

Port 2

Port 1

Port 0

J3
J4

J2
LSISAS1064E

J5
J8

J6

J7

Link Not Present LEDs
Activity LEDs

Two Light Pipes,
One Green and
One Bi-color

3.1.1.3

J1

•

J1: PCI Express x4 lane board edge connector

•

J2, J5–J7: SATA internal right-angle connectors

•

J3: 4-pin, right angle, 0.1” pitch, pin header for driving external
activity LEDs

Physical Characteristics
The LSISAS3041E and LSISAS3041EL boards are 6.6 inches x
2.713 inches. PCI Express x4 connection is made through the edge
connector J1. The component height on the top and bottom of the
LSISAS3041E and LSISAS3041EL boards follows the PCI Express
specifications.

Characteristics of the LSI PCIe to SAS Host Adapters
Version 1.0

Copyright © 2006 by LSI Logic Corporation. All rights reserved.

3-3

3.1.2

LSISAS3080E and LSISAS3080EL Host Adapters Characteristics
The LSISAS3080E and LSISAS3080EL are identical HBAs with the
exception of the PCI bracket. The LSISAS3080E uses a standard PCI
bracket and the LSISAS3080EL uses a low-profile (LPPCI) PCI bracket.
Figure 3.2 shows the HBAs and their brackets.

3.1.2.1

LEDs
The LSISAS3080E and LSISAS3080EL host adapters have eight LEDs,
labeled A0–A7, that turn green to indicate an activity condition on any of
the eight phys. There are eight LEDs, labeled LNP0–LNP7, that turn
yellow to indicate a fault condition on any of the eight phys. See
Figure 3.2 for LED locations.
The LSISAS3080E and LSISAS3080EL host adapters have two light
pipes routed through the PCI bracket. One light pipe turns green to
indicate activity on any phy. The other light pipe is bi-color. It flashes
green to indicate the LSISAS1068E heartbeat, or it turns yellow when the
LSISAS1068E firmware detects a fault condition.

3.1.2.2

Connectors
This section provides a description of the four different connectors on the
LSISAS3080E and LSISAS3080EL host adapters. See Figure 3.2 for
connector locations.
PCI Express Connector (J1) – The PCI Express interface has eight
PCI Express phys, which provide possible host-side maximum
transmission and reception rates of up to 4.0 Gbytes/s. The
LSISAS3080E or LSISAS3080EL supports x8, x4, and x1 PCI Express
link widths, and automatically downshifts if plugged into either a x4
connector or into a x8 connector that is wired as a x4 connector. The PCI
Express connection is made through the edge connector J1. The signal
definitions and pin numbers conform to the PCI Express specifications.
SAS/SATA Connectors (J2 and J5) – The LSISAS3080E and
LSISAS3080EL support SAS connections through connectors J2 and J3.
The J2 and J3 connectors are SFF-8484 SAS internal right-angle
connectors with four sideband lines.

3-4

Host Adapter Characteristics
Version 1.0

Copyright © 2006 by LSI Logic Corporation. All rights reserved.

Activity LED Header (J6) – 4-pin, right angle, 0.1-inch pitch, pin header
for driving external activity LEDs.
Figure 3.2

LSISAS3080E and LSISAS3080EL Board Layout

LSISAS3080E
Standard PCI Bracket
LSISAS3080EL
Low-Profile
(LPPCI)
PCI Bracket
J6

J2

J5

Link
Activity
Not Present LEDs
LEDs

LSISAS1068E
Two Light Pipes,
One Green and
One Bi-color
J1

3.1.2.3

•

J1: PCI Express x8 lane board edge connector

•

J2, J5: SFF-8484 SAS internal right-angle connectors with four
sideband lines

•

J6: 4-pin, right angle, 0.1” pitch, pin header for driving external
activity LED

Physical Characteristics
The LSISAS3080E and LSISAS3080EL boards are 6.3 inches x
2.713 inches. PCI Express connection is made through the edge
connector J1. The component height on the top and bottom of the
LSISAS3080E and LSISAS3080EL boards follows the PCI Express
specifications.

Characteristics of the LSI PCIe to SAS Host Adapters
Version 1.0

Copyright © 2006 by LSI Logic Corporation. All rights reserved.

3-5

3.1.3

LSISAS3081E and LSISAS3081EL Host Adapters Characteristics
The LSISAS3081E and LSISAS3081EL are identical HBAs with the
exception of the PCI bracket. The LSISAS3081E uses a standard PCI
bracket and the LSISAS3081EL uses a low-profile (LPPCI) PCI bracket.
Figure 3.3 shows the HBAs and their brackets.

3.1.3.1

LEDs
The LSISAS3081E and LSISAS3081EL host adapters have eight LEDs,
labeled A0–A7, that turn green to indicate an activity condition on any of
the eight phys. There are eight LEDs, labeled LNP0–LNP7, that turn
yellow to indicate a fault condition on any of the eight phys. See
Figure 3.3 for LED locations.
The LSISAS3081E and LSISAS3081EL host adapters have two light
pipes routed through the PCI bracket. One light pipe turns green to
indicate activity on any phy. The other light pipe is bi-color. It flashes
green to indicate the LSISAS1068E heartbeat, or it turns yellow when the
LSISAS1068E firmware detects a fault condition.

3.1.3.2

Connectors
This section provides a description of the four different connectors on the
LSISAS3081E and LSISAS3081EL host adapters. See Figure 3.2 for
connector locations.
PCI Express Connector (J1) – The PCI Express interface has eight
PCI Express phys, which provide possible host-side maximum
transmission and reception rates of up to 4.0 Gbytes/s. The
LSISAS3081E or LSISAS3081EL supports x8, x4, and x1 PCI Express
link widths, and automatically downshifts if plugged into either a x4
connector or into a x8 connector that is wired as a x4 connector. The PCI
Express connection is made through the edge connector J1. The signal
definitions and pin numbers conform to the PCI Express specifications.
SAS/SATA Connectors (J2 and J5) – The LSISAS3081E and
LSISAS3081EL support SAS connections through connectors J2 and J5.
The J2 and J5 connectors are SFF-8087 mini-SAS internal right-angle
connectors.

3-6

Host Adapter Characteristics
Version 1.0

Copyright © 2006 by LSI Logic Corporation. All rights reserved.

Activity LED Header (J6) – 4-pin, right angle, 0.1-inch pitch, pin header
for driving external activity LEDs.
Figure 3.3

LSISAS3081E and LSISAS3081EL Board Layout

LSISAS3081E
Standard PCI Bracket
LSISAS3081EL
Low-Profile
(LPPCI)
PCI Bracket
J6

J2

J5
Link
Activity
Not Present LEDs
LEDs

LSISAS1068E
Two Light Pipes,
One Green and
One Bi-color
J1

3.1.3.3

•

J1: PCI Express x8 lane board edge connector

•

J2, J5: SFF-8087 mini-SAS internal right-angle connectors

•

J6: 4-pin, right angle, 0.1” pitch, pin header for driving external
activity LED

Physical Characteristics
The LSISAS3081E and LSISAS3081EL boards are 6.6 inches x
2.713 inches. PCI Express connection is made through the edge
connector J1. The component height on the top and bottom of the
LSISAS3081E and LSISAS3081EL boards follows the PCI Express
specifications.

Characteristics of the LSI PCIe to SAS Host Adapters
Version 1.0

Copyright © 2006 by LSI Logic Corporation. All rights reserved.

3-7

3.1.4

LSISAS3442E and LSISAS3442EL Host Adapters Characteristics
The LSISAS3442E and LSISAS3442EL are the same HBA with the
exception of the PCI bracket. The LSISAS3442E uses a standard PCI
bracket and the LSISAS3442EL uses a low-profile (LPPCI) PCI bracket.
Figure 3.4 shows the HBAs and their brackets.

3.1.4.1

LEDs
The LSISAS3442E and LSISAS3442EL host adapters have eight LEDs,
labeled A0–A7, that turn green to indicate an activity condition on any of
the eight phys. There are eight LEDs, labeled LNP0–LNP7, that turn
yellow to indicate a fault condition on any of the eight phys. See
Figure 3.4 for LED locations.
The LSISAS3442E and LSISAS3442EL host adapters have two light
pipes routed through the PCI bracket. One light pipe turns green to
indicate activity on any phy. The other light pipe is bi-color. It flashes
green to indicate the LSISAS1068E heartbeat, or it turns yellow when the
LSISAS1068E firmware detects a fault condition.

3.1.4.2

Connectors
This section provides a description of the four different connectors on the
LSISAS3442E and LSISAS3442EL host adapters. See Figure 3.4 for
connector locations.
PCI Express Connector (J1) – The PCI Express interface has eight
PCI Express phys, which provide possible host-side maximum
transmission and reception rates of up to 4.0 Gbytes/s. The
LSISAS3442E or LSISAS3442EL supports x8, x4, and x1 PCI Express
link widths, and automatically downshifts if plugged into either a x4
connector or into a x8 connector that is wired as a x4 connector. The
connection is made through the edge connector J1. The signal
definitions and pin numbers conform to the PCI Express specifications.
SAS/SATA Connectors (J2 and J5) – The LSISAS3442E and
LSISAS3442EL support SAS connections through connectors J2 and J5.
The J5 connector is an SFF-8484 SAS internal right-angle connector
with four sideband lines. The J2 connector is an SFF-8470 SAS external
right-angle connector.

3-8

Host Adapter Characteristics
Version 1.0

Copyright © 2006 by LSI Logic Corporation. All rights reserved.

Activity LED Header (J6) – 4-pin, right angle, 0.1-inch pitch, pin header
for driving external activity LEDs.
Figure 3.4

LSISAS3442E and LSISAS3442EL Board Layout

LSISAS3442E
Standard PCI Bracket
LSISAS3442EL
Low-Profile
(LPPCI)
PCI Bracket
J6
Two Light Pipes,
One Green and
One Bi-color

LSISAS1068E

J2

Link
Not Present
LEDs
Activity
LEDs

J5

J1

3.1.4.3

•

J1: PCI Express x8 lane board edge connector

•

J2: SFF-8470 SAS external right-angle connector

•

J5: SFF-8484 SAS internal right-angle connector with four sideband
lines

•

J6: 4-pin, right angle, 0.1” pitch, pin header for driving external
activity LED

Physical Characteristics
The LSISAS3442E and LSISAS3442EL boards are 6.6 inches x
2.713 inches. PCI Express x8 connection is made through the edge
connector J1. The component height on the top and bottom of the
LSISAS3442E and LSISAS3442EL boards follows the PCI Express
specifications.

Characteristics of the LSI PCIe to SAS Host Adapters
Version 1.0

Copyright © 2006 by LSI Logic Corporation. All rights reserved.

3-9

3.1.5

LSISAS3443E and LSISAS3443EL Host Adapters Characteristics
The LSISAS3443E and LSISAS3443EL are the same HBA with the
exception of the PCI bracket. The LSISAS3443E uses a standard PCI
bracket and the LSISAS3443EL uses a low-profile (LPPCI) PCI bracket.
Figure 3.5 shows the HBAs and their brackets.

3.1.5.1

LEDs
The LSISAS3443E and LSISAS3443EL host adapters have eight LEDs,
labeled A0–A7, that turn green to indicate an activity condition on any of
the eight phys. There are eight LEDs, labeled LNP0–LNP7, that turn
yellow to indicate a fault condition on any of the eight phys. See
Figure 3.5 for LED locations.
The LSISAS3443E and LSISAS3443EL host adapters have two light
pipes routed through the PCI bracket. One light pipe turns green to
indicate activity on any phy. The other light pipe is bi-color. It flashes
green to indicate the LSISAS1068E heartbeat, or it turns yellow when the
LSISAS1068E firmware detects a fault condition.

3.1.5.2

Connectors
This section provides a description of the four different connectors on the
LSISAS3443E and LSISAS3443EL host adapters. See Figure 3.5 for
connector locations.
PCI Express Connector (J1) – The PCI Express interface has eight
PCI Express phys, which provide possible host-side maximum
transmission and reception rates of up to 4.0 Gbytes/s. The
LSISAS3443E or LSISAS3443EL supports x8, x4, and x1 PCI Express
link widths, and automatically downshifts if plugged into either a x4
connector or into a x8 connector that is wired as a x4 connector. The
connection is made through the edge connector J1. The signal
definitions and pin numbers conform to the PCI Express specifications.
SAS/SATA Connectors (J2 and J5) – The LSISAS3443E and
LSISAS3443EL support SAS connections through connectors J2 and J5.
The J2 connector is an SFF-8088 mini-SAS external connector. The J5
connector is an SFF-8087 mini-SAS internal connector.

3-10

Host Adapter Characteristics
Version 1.0

Copyright © 2006 by LSI Logic Corporation. All rights reserved.

Activity LED Header (J6) – 4-pin, right angle, 0.1-inch pitch, pin header
for driving external activity LEDs.
Figure 3.5

LSISAS3443E and LSISAS3443EL Board Layout

LSISAS3443E
Standard PCI Bracket

LSISAS3443EL
Low-Profile
(LPPCI)
PCI Bracket
J6
Two Light Pipes,
One Green and
One Bi-color

J5
LSISAS1068E

SFF-8088
Mini-SAS
Connector

J2

Link
Not Present
LEDs
Activity
LEDs

J1

3.1.5.3

•

J1: PCI Express x8 lane board edge connector

•

J2: SFF-8088 mini-SAS external right-angle connector

•

J5: SFF-8087 mini-SAS internal right-angle connector with four
sideband lines

•

J6: 4-pin, right angle, 0.1” pitch, pin header for driving external
activity LED

Physical Characteristics
The LSISAS3443E and LSISAS3443EL boards are 6.6 inches x
2.713 inches. PCI Express x8 connection is made through the edge
connector J1. The component height on the top and bottom of the
LSISAS3443E and LSISAS3443EL boards follows the PCI Express
specifications.

Characteristics of the LSI PCIe to SAS Host Adapters
Version 1.0

Copyright © 2006 by LSI Logic Corporation. All rights reserved.

3-11

3.1.6

LSISAS3444E and LSISAS3444EL Host Adapters Characteristics
The LSISAS3444E and LSISAS3444EL are the same HBA with the
exception of the PCI bracket. The LSISAS3444E uses a standard PCI
bracket and the LSISAS3444EL uses a low-profile (LPPCI) PCI bracket.
Figure 3.6 shows the HBAs and their brackets.

3.1.6.1

LEDs
The LSISAS3444E and LSISAS3444EL host adapters have eight LEDs,
labeled A0–A7, that turn green to indicate an activity condition on any of
the eight phys. There are eight LEDs, labeled LNP0–LNP7, that turn
yellow to indicate a fault condition on any of the eight phys. See
Figure 3.6 for LED locations.
The LSISAS3444E and LSISAS3444EL host adapters have two light
pipes routed through the PCI bracket. One light pipe turns green to
indicate activity on any phy. The other light pipe is bi-color. It flashes
green to indicate the LSISAS1068E heartbeat, or it turns yellow when the
LSISAS1068E firmware detects a fault condition.

3.1.6.2

Connectors
This section provides a description of the seven different connectors on
the LSISAS3444E and LSISAS3444EL host adapters. See Figure 3.6 for
connector locations.
PCI Express Connector (J1) – The PCI Express interface has eight
PCI Express phys, which provide possible host-side maximum
transmission and reception rates of up to 4.0 Gbytes/s. The
LSISAS3444E or LSISAS3444EL supports x8, x4, and x1 PCI Express
link widths, and automatically downshifts if plugged into either a x4
connector or into a x8 connector that is wired as a x4 connector. The
connection is made through the edge connector J1. The signal
definitions and pin numbers conform to the PCI Express specifications.
SAS/SATA Connectors (J2 and J3, J6–J8) – The LSISAS3444E and
LSISAS3444EL support SAS connections through these connectors. The
J3 and J6–J8 connectors are SATA internal latching right-angle
connectors. The J2 connector is an SFF-8088 mini-SAS external rightangle connector.

3-12

Host Adapter Characteristics
Version 1.0

Copyright © 2006 by LSI Logic Corporation. All rights reserved.

Activity LED Header (J9) – 4-pin, right angle, 0.1-inch pitch, pin header
for driving external activity LEDs.
Figure 3.6

LSISAS3444E and LSISAS3444EL Board Layout

LSISAS3444E
Standard PCI Bracket

LSISAS3444EL
Low-Profile
(LPPCI)
PCI Bracket

Port 3

Port 2

Port 1

Port 0

J3

J6

J7

J8

Two Light Pipes,
One Green and
One Bi-color

J4
J9
LSISAS1068E

SFF-8088
Mini-SAS
Connector

J2

Link Not
Present
LEDs
Activity
LEDs

J1

3.1.6.3

•

J1: PCI Express x8 lane board edge connector

•

J2: SFF-8088 mini-SAS external right-angle connector

•

J3, J6–J8: SATA internal latching right-angle connectors

•

J9: 4-pin, right angle, 0.1” pitch, pin header for driving external
activity LED

Physical Characteristics
The LSISAS3444E and LSISAS3444EL boards are 6.6 inches x
2.713 inches. PCI Express x8 connection is made through the edge
connector J1. The component height on the top and bottom of the
LSISAS3444E and LSISAS3444EL boards follows the PCI Express
specifications.

Characteristics of the LSI PCIe to SAS Host Adapters
Version 1.0

Copyright © 2006 by LSI Logic Corporation. All rights reserved.

3-13

3.1.7

LSISAS3800E Host Adapter Characteristics
The LSISAS3800E uses a standard PCI bracket. Figure 3.7 shows the
HBA and its bracket.

3.1.7.1

LEDs
The LSISAS3800E host adapter has eight LEDs, labeled A0–A7, that
turn green to indicate an activity condition on any of the eight phys.
There are eight LEDs, labeled LNP0–LNP7, that turn yellow to indicate
a fault condition on any of the eight phys. See Figure 3.7 for LED
locations.
The LSISAS3800E host adapter has two light pipes routed through the
PCI bracket. One light pipe turns green to indicate activity on any phy.
The other light pipe is bi-color. It flashes green to indicate the
LSISAS1068E heartbeat, or it turns yellow when the LSISAS1068E
firmware detects a fault condition.

3.1.7.2

Connectors
This section provides a description of the four different connectors on the
LSISAS3800E host adapter. See Figure 3.7 for connector locations.
PCI Express Connector (J1) – The PCI Express interface has eight
PCI Express phys, which provide possible host-side maximum
transmission and reception rates of up to 4.0 Gbytes/s. The
LSISAS3800E supports x8, x4, and x1 PCI Express link widths, and
automatically downshifts if plugged into either a x4 connector or into a
x8 connector that is wired as a x4 connector. The connection is made
through the edge connector J1. The signal definitions and pin numbers
conform to the PCI Express specifications.
SAS/SATA Connectors (J2 and J3) – The LSISAS3800E supports
SAS/SATA connections through connectors J2 and J3. The J2 and J3
connectors are SFF-8470 SAS external right-angle connectors.
Activity LED Header (J4) – 4-pin, right angle, 0.1-inch pitch, pin header
for driving external activity LEDs.

3-14

Host Adapter Characteristics
Version 1.0

Copyright © 2006 by LSI Logic Corporation. All rights reserved.

Figure 3.7

LSISAS3800E Board Layout

LSISAS3800E
Standard
PCI Bracket

J4

J3

Two Light Pipes,
One Green and
One Bi-color

LSISAS1068E

Link Not
Present
LEDs
Activity
LEDs

J2
J1

3.1.7.3

•

J1: PCI Express x8 lane board edge connector

•

J2 and J3: SFF-8470 SAS external right-angle connector

•

J4: 4-pin, right angle, 0.1” pitch, pin header for driving external
activity LED

Physical Characteristics
The LSISAS3800E is 6.6 inches x 4.375 inches. PCI Express connection
is made through the edge connector J1. The component height on the
top and bottom of the LSISAS3800E board follows the PCI Express
specifications.

Characteristics of the LSI PCIe to SAS Host Adapters
Version 1.0

Copyright © 2006 by LSI Logic Corporation. All rights reserved.

3-15

3.1.8

LSISAS3801E and LSISAS3801EL Host Adapters Characteristics
The LSISAS3801E and LSISAS3801EL are the same HBA with the
exception of the PCI bracket. The LSISAS3801E uses a standard PCI
bracket and the LSISAS3801EL uses a low-profile (LPPCI) PCI bracket.
Figure 3.8 shows the HBAs and their brackets.

3.1.8.1

LEDs
The LSISAS3801E and LSISAS3801EL host adapters have eight LEDs,
labeled A0–A7, that turn green to indicate an activity condition on any of
the eight phys. There are also eight LEDs, labeled LNP0–LNP7, that turn
yellow to indicate a fault condition on any of the eight phys. See
Figure 3.8 for LED locations.
The LSISAS3801E and LSISAS3801EL host adapters contain two
additional LEDs. One LED turns green to indicate activity on any phy.
The other LED is bi-color. It flashes green to indicate the LSISAS1068E
heartbeat, or it turns yellow when the LSISAS1068E firmware detects a
fault condition.

3.1.8.2

Connectors
This section provides a description of the four different types of
connectors on the LSISAS3801E and LSISAS3801EL host adapters.
See Figure 3.8 for connector locations.
PCI Express Connector (J1) – The PCI Express interface has eight
PCI Express phys, which provide possible host-side maximum
transmission and reception rates of up to 4.0 Gbytes/s. The
LSISAS3801E or LSISAS3801EL supports x8, x4, and x1 PCI Express
link widths, and automatically downshifts if plugged into either a x4
connector or into a x8 connector that is wired as a x4 connector. The
connection is made through the edge connector J1. The signal
definitions and pin numbers conform to the PCI Express specifications.
SAS/SATA Connectors (J2 and J3) – The LSISAS3801E and
LSISAS3801EL support SAS connections through connectors J2 and J3.
These connectors are SFF-8088 mini-SAS external right-angle
connectors.

3-16

Host Adapter Characteristics
Version 1.0

Copyright © 2006 by LSI Logic Corporation. All rights reserved.

Activity LED Header (J4) – 4-pin, right angle, 0.1-inch pitch, pin header
for driving external activity LEDs.
Figure 3.8

LSISAS3801E and LSISAS3801EL Board Layout

LSISAS3801E
Standard
PCI Bracket

LSISAS3801EL
Low-Profile
(LPPCI)
PCI Bracket

J4

J3

LSISAS1068

SFF-8088
Mini-SAS
Connectors

Link Not Present
Activity

J2

J1

3.1.8.3

•

J1: PCI Express x8 lane board edge connector

•

J2 and J3: SFF-8088 mini-SAS external right-angle connectors

•

J4: 4-pin, right angle, 0.1” pitch, pin header for driving external
activity LED

Physical Characteristics
The LSISAS3801E and LSISAS3801EL boards are 6.6 inches x
2.713 inches. PCI Express x8 connection is made through the edge
connector J1. The component height on the top and bottom of the
LSISAS3801E and LSISAS3801EL boards follows the PCI Express
specifications.

Characteristics of the LSI PCIe to SAS Host Adapters
Version 1.0

Copyright © 2006 by LSI Logic Corporation. All rights reserved.

3-17

3.2

Electrical and Environmental Specifications
The design and implementation of the LSI PCIe to SAS host adapters
minimize electromagnetic emissions, susceptibility to radio frequency
energy, and the effects of electrostatic discharge. The board carries the
CE mark, C-Tick mark, Canadian Compliance Statement, Korean MIC,
Taiwan BSMI, Japan VCCI, FCC Class B and is marked with the FCC
Self-Certification logo. The board also meets the requirements of CISPR
Class B.

3.2.1

Electrical Characteristics
Table 3.1 lists the maximum power requirements for the LSI PCIe to SAS
host adapters under normal operation.
Table 3.1

Maximum Power Requirements
PCI Express
+12.0 V

Power

Operating Range

LSISAS3041E,
LSISAS3041EL

0.5 A

6.0 W

0 ˚C to 60 ˚C

LSISAS3080E,
LSISAS3080EL

0.5 A

6.0 W

0 ˚C to 60 ˚C

LSISAS3081E,
LSISAS3081EL

0.5 A

6.0 W

0 ˚C to 60 ˚C

LSISAS3442E,
LSISAS3442EL

0.5 A

6.0 W

0 ˚C to 60 ˚C

LSISAS3443E,
LSISAS3443EL

0.5 A

6.0 W

0 ˚C to 60 ˚C

LSISAS3444E,
LSISAS3444EL

0.5 A

6.0 W

0 ˚C to 60 ˚C

LSISAS3800E

0.5 A

6.0 W

0 ˚C to 60 ˚C

LSISAS3801E,
LSISAS3801EL

0.5 A

6.0 W

0 ˚C to 60 ˚C

Host Adapters

3-18

Host Adapter Characteristics
Version 1.0

Copyright © 2006 by LSI Logic Corporation. All rights reserved.

3.2.2

Thermal and Atmospheric Characteristics
The atmospheric characteristics for the LSI PCIe to SAS host adapters
are:

•

Temperature range: 0 ˚C to 60 ˚C (dry bulb)

•

Relative humidity range: 5% to 90% non-condensing

•

Maximum dew point temperature: 32 ˚C

The following parameters define the storage and transit environment for
the LSI PCIe to SAS host adapters:

3.2.3

•

Temperature range: −45 ˚C to +105 ˚C (dry bulb)

•

Relative humidity range: 5% to 90% non-condensing

Safety Characteristics
All LSI PCIe to SAS host adapters meet or exceed the requirements of
UL flammability rating 94V-0. Each bare board is marked with the
supplier’s name or trademark, type, and UL flammability rating. Because
these boards are installed in a PCI Express bus slot, all voltages are
below the SELV 42.4 V limit.

Electrical and Environmental Specifications
Version 1.0

Copyright © 2006 by LSI Logic Corporation. All rights reserved.

3-19

3-20

Host Adapter Characteristics
Version 1.0

Copyright © 2006 by LSI Logic Corporation. All rights reserved.

Customer Feedback

We would appreciate your feedback on this document. Please copy the
following page, add your comments, and fax it to us at the number
shown.
If appropriate, please also fax copies of any marked-up pages from this
document.
Important:

Please include your name, phone number, fax number, and
company address so that we may contact you directly for
clarification or additional information.

Thank you for your help in improving the quality of our documents.

PCIe to 3.0 Gbit/s SAS Host Adapters User’s Guide
Version 1.0

Copyright © 2006 by LSI Logic Corporation. All rights reserved.

Reader’s Comments
Fax your comments to:

LSI Logic Corporation
Technical Publications
M/S AF-198
Fax: 408.433.4333

Please tell us how you rate this document: PCIe to 3.0 Gbit/s SAS Host
Adapters User’s Guide. Place a check mark in the appropriate blank for
each category.
Excellent Good Average
Completeness of information
Clarity of information
Ease of finding information
Technical content
Usefulness of examples and
illustrations
Overall manual

Fair

Poor

____
____
____
____
____

____
____
____
____
____

____
____
____
____
____

____
____
____
____
____

____
____
____
____
____

____

____

____

____

____

What could we do to improve this document?

If you found errors in this document, please specify the error and page
number. If appropriate, please fax a marked-up copy of the page(s).

Please complete the information below so that we may contact you
directly for clarification or additional information.
Date

Name
Telephone
Title
Department
Company Name
Street
City, State, Zip

Fax
Mail Stop

Customer Feedback
Version 1.0

Copyright © 2006 by LSI Logic Corporation. All rights reserved.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
Page Mode                       : UseOutlines
XMP Toolkit                     : 3.1-702
Create Date                     : 2006:08:02 17:06:30Z
Creator Tool                    : FrameMaker 6.0
Modify Date                     : 2007:05:29 13:59:02-07:00
Metadata Date                   : 2007:05:29 13:59:02-07:00
Format                          : application/pdf
Description                     : This document contains all of the PCI Express to 3.0 Gbit/s Serial Attached SCSI (SAS) Host Adapters. This book describes the LSI PCI Express to SAS host adapters, and how to install them in a system. It provides the characteristics of each HBA and the environmental and electrical specifications.
Title                           : PCI Express to 3.0 Gbit/s Serial Attached SCSI (SAS) Host Adapters User’s Guide
Keywords                        : Fusion-MPT Technology, PCI Express, Serial Attached SCSI (SAS) Technology, Storage Adapters, Storage ICs,  SCSI HBAs, SCSI ICs, LSISAS3041E, LSISAS3041EL, LSISAS3080E, LSISAS3080EL, LSISAS3081E, LSISAS3081EL, LSISAS3442E, LSISAS3442EL, LSISAS3443E, LSISAS3443EL, LSISAS3444E, LSISAS3444EL, LSISAS3800E, LSISAS3801E, and LSISAS3801EL
Producer                        : Acrobat Distiller 4.05 for Sparc Solaris
Document ID                     : uuid:758fa654-2377-4c1f-b3b4-4ae3c001fa3c
Instance ID                     : uuid:8ec7cfec-62ef-4384-b61f-e21aa1814f32
Page Count                      : 46
Subject                         : This document contains all of the PCI Express to 3.0 Gbit/s Serial Attached SCSI (SAS) Host Adapters. This book describes the LSI PCI Express to SAS host adapters, and how to install them in a system. It provides the characteristics of each HBA and the environmental and electrical specifications.
Creator                         : FrameMaker 6.0
EXIF Metadata provided by EXIF.tools

Navigation menu