566DG Ortho-Biotic Clinical Care
Drop Arm Recliner

Operating Instructions

566DG-INS-LAB
© Graham-Field Health Products 2005

IMPORTANT: READ THIS MANUAL BEFORE OPERATING
YOUR ORTHO-BIOTIC CLINICAL CARE DROP ARM RECLINER

WARNINGS
Warning: Read entire sheet before assembly
or operation.

Warning: Occupant weight should not
exceed 350 lbs.

Warning: Periodically inspect all parts and
replace as needed.

Warning: Casters must be locked at all times,
except during transit.

Warning: Do not use near open flame, as the
chair may be a “combustion source”.

CARE & MAINTENANCE
Every three months:
• Check and clean casters • tighten nuts • check brakes on casters •
• check and clean lock recline mechanism •
Check recliner mechanism for operation in all positions with assistant seated in recliner.
For upholstery maintenance and stain removal, the following hints will be helpful:
Ordinary Dirt: Wash with warm water and a mild Paint, Shoe Polish, Heel Marks: Remove
immediately! Use a white cloth dampened in
soap or detergent.
kerosene, naphtha or turpentine. Do not use
Stubborn Dirt: Using a soft bristle brush, follow paint remover or liquid brush cleaners.
directions above.
Tars, Asphalt, Creosote: Remove to prevent
Ground-in Dirt: Scrub with powdered cleanser or staining. Clean area with kerosene or naphtha.
Caution: When using kerosene or naphtha, do so
similar detergent.
in a well ventilated area and keep away
Chewing Gum: Scrape carefully; remove with
from fire and flame.
kerosene or naphtha.
Waxing and Refinishing: Improves wearability.
Nail Polish and Remover: Blot immediately to Use any quality paste wax.
prevent damage.
A diluted solution of 10% (or less) of bleach or
Ball Point Pen: Blot immediately with a white Clorox may be used when cleaning this chair.
cloth dampened in water or mineral oil.

2

566DG Ortho Biotic Clinical Care® Recliner Operating Instructions

Upholstered Back
Upholstered Armrest

Padded Push Handle

Upholstered Seat
Upholstered Legrest

Upholstered Footrest
Drop Arm

Telescoping Tubes

Front Casters
with Tread
Lock

Rear Swivel Locking
Casters with Tread lock

Drop Arm Pull Button
(Behind Table)
Frame
Trendelenburg Release Bar
Fold Down Side Tables

To Operate Drop Arm
To Drop Arm:
To Raise Arm:
1. Lift fold down Side table away from frame to 1. Grasp armrest with one hand and pull upwards
expose button.
while pulling pull button out. Pull up on arm
2. Pull button out while gently pushing down on
evenly until pull button locks into place.
center of armrest until arm is in the full down 2. Ensure arm is secure by pushing down on
position.
center of armrest.

566DG Ortho Biotic Clinical Care® Recliner Operating Instructions

3

UPHOLSTERED BACK ASSEMBLY
1. Lift the skirt on the rear of the upholstered
back, fasten skirt up with a small piece of
tape to fully expose the "KD Bracket" that are
to be mated to the recliner mechanism.

upholstered back "KD Brackets". The top of
bayonet link should be even with top of KD
Bracket. (See fig. 1)

4. Once back is properly seated onto
2. Carefully guide upholstered back onto the
mechanism insert the threaded knob thru
mechanism inserting both "bayonet links" at
"bayonet link", 'ED Bracket" and steel tube.
the same time thru cutouts in vinyl.
Secure hand tight.
3. Push down on the back until the mechanism
"bayonet links" are properly engaged into the

5. Remove tape lower upholstery skirt and
secure to Velcro.

Upholstered Back

Upholstered Skirt

Threaded Knobs

Upholstered Back’s
KD Brackets

Steel Tube
Mechanism’s
Bayonet Links

Bracket and Link to be even

Threaded Knob thru large
hole in Bayonet Link

KD Bracket

Bayonet Link

4

566DG Ortho Biotic Clinical Care® Recliner Operating Instructions

CASTER OPERATION (FRONT)

Tread Lock Pedal

NOTE: This chair is equipped with four casters for
improved maneuverability. The front
casters are equipped with tread locks.
To Lock: Step on the back edge of the black
pedal until it latches and stays down.
Figure 5

To Unlock: Step on the top edge of the pedal.

To lock swivel

CASTER OPERATION (REAR)

To unlock wheel

NOTE: The chair is equipped with four casters for
improved maneuverability. Right rear
caster is also equipped with locking
features. Swivel lock will aid the chair in
rolling straight.

To lock wheel

Lock: To prevent the rear casters from swiveling
and wheel turning, step on the rear pedal of the
caster until it latches.

Figure 4

Armrest

Unlock: Step on middle button to unlatch.

TABLE OPERATION
To Raise: Raise table all the way up and slide in
toward the armrest until tabs engage slots in
mount bracket. Press down lightly on table to
ensure lock tabs are engaged.
To Lower: Lift table up until tabs disengage slots
and pull table away from armrest. Lower table to
self-storing position.

Table
(Disengaged Position)

3/8 Clevis Pin
Attachment

Table Mount
Bracket
Tabs engage into
slots on table
mount bracket

Table
(Engaged
Position)

Table
(Stored Position)

SIDE PANEL REMOVAL
To Remove: Grasp upholstered side panel at
back of panel and pull sharply out from chair
until locking clips release side panel.

Side Panel

To Install: Insert side panel into chair frame by
lining up side panel clips with tubes on frame
and pushing firmly.
Drop Arm Pull Button
(Behind Table)
566DG Ortho Biotic Clinical Care® Recliner Operating Instructions

5

SEAT POSITIONING
Reclining by Patient: Place hands on armrest
and push body against chair's back to recline
yourself to desired position. To bring yourself
up, place hands on armrest and pull yourself up
while leaning your body forward away from the
chairs back.
Reclining by Attendant: Standing on either side
of the chair, grasp the armrest with one hand
and push handle with the other hand. Push back
on push handle to recline and pull forward to
raise the chair.

Upright Position

Infinite Position Between TV and Full Recline

TV Position

TRENDELENBURG POSITION:
Standing on either side of the chair, grasp the
armrest with one hand while holding the recliner
back with the other. With your foot, push down
on the release bar while gently pushing down
with your hand on the recliners back until it
comes to a stop. To bring chair out of
Trendelenburg, stand on either side of the chair,
grasp the armrest with one hand and push
handle with the other hand and pull forward on
the push handle.
Trendelenburg Position

6

566DG Ortho Biotic Clinical Care® Recliner Operating Instructions

NOTES

U.S.A., Corporate Headquarters:
Graham-Field Health Products
2935 Northeast Parkway
Atlanta, Georgia 30360
telephone: 800-347-5678, 770-447-1609
fax: 800-726-0601, 678-291-3232

http://www.grahamfield.com



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Page Count                      : 8
Producer                        : QuarkXPress(tm) 6.5
Create Date                     : 2005:06:02 17:08:26
X Press Private                 : %%DocumentProcessColors:.%%EndComments
Title                           : 566DG
Creator                         : QuarkXPress(tm) 6.5
EXIF Metadata provided by EXIF.tools

Navigation menu