Lumex Syatems Zhejiang Co Ltd Range 566Dg Users Manual
566DG to the manual 55791fc1-ea74-4311-9c10-916878256d11
2015-02-09
: Lumex-Syatems Lumex-Syatems-Zhejiang-Lumex-Syatems-Co-Ltd-Range-566Dg-Users-Manual-576485 lumex-syatems-zhejiang-lumex-syatems-co-ltd-range-566dg-users-manual-576485 lumex-syatems pdf
Open the PDF directly: View PDF .
Page Count: 8
Download | |
Open PDF In Browser | View PDF |
566DG Ortho-Biotic Clinical Care Drop Arm Recliner Operating Instructions 566DG-INS-LAB © Graham-Field Health Products 2005 IMPORTANT: READ THIS MANUAL BEFORE OPERATING YOUR ORTHO-BIOTIC CLINICAL CARE DROP ARM RECLINER WARNINGS Warning: Read entire sheet before assembly or operation. Warning: Occupant weight should not exceed 350 lbs. Warning: Periodically inspect all parts and replace as needed. Warning: Casters must be locked at all times, except during transit. Warning: Do not use near open flame, as the chair may be a “combustion source”. CARE & MAINTENANCE Every three months: • Check and clean casters • tighten nuts • check brakes on casters • • check and clean lock recline mechanism • Check recliner mechanism for operation in all positions with assistant seated in recliner. For upholstery maintenance and stain removal, the following hints will be helpful: Ordinary Dirt: Wash with warm water and a mild Paint, Shoe Polish, Heel Marks: Remove immediately! Use a white cloth dampened in soap or detergent. kerosene, naphtha or turpentine. Do not use Stubborn Dirt: Using a soft bristle brush, follow paint remover or liquid brush cleaners. directions above. Tars, Asphalt, Creosote: Remove to prevent Ground-in Dirt: Scrub with powdered cleanser or staining. Clean area with kerosene or naphtha. Caution: When using kerosene or naphtha, do so similar detergent. in a well ventilated area and keep away Chewing Gum: Scrape carefully; remove with from fire and flame. kerosene or naphtha. Waxing and Refinishing: Improves wearability. Nail Polish and Remover: Blot immediately to Use any quality paste wax. prevent damage. A diluted solution of 10% (or less) of bleach or Ball Point Pen: Blot immediately with a white Clorox may be used when cleaning this chair. cloth dampened in water or mineral oil. 2 566DG Ortho Biotic Clinical Care® Recliner Operating Instructions Upholstered Back Upholstered Armrest Padded Push Handle Upholstered Seat Upholstered Legrest Upholstered Footrest Drop Arm Telescoping Tubes Front Casters with Tread Lock Rear Swivel Locking Casters with Tread lock Drop Arm Pull Button (Behind Table) Frame Trendelenburg Release Bar Fold Down Side Tables To Operate Drop Arm To Drop Arm: To Raise Arm: 1. Lift fold down Side table away from frame to 1. Grasp armrest with one hand and pull upwards expose button. while pulling pull button out. Pull up on arm 2. Pull button out while gently pushing down on evenly until pull button locks into place. center of armrest until arm is in the full down 2. Ensure arm is secure by pushing down on position. center of armrest. 566DG Ortho Biotic Clinical Care® Recliner Operating Instructions 3 UPHOLSTERED BACK ASSEMBLY 1. Lift the skirt on the rear of the upholstered back, fasten skirt up with a small piece of tape to fully expose the "KD Bracket" that are to be mated to the recliner mechanism. upholstered back "KD Brackets". The top of bayonet link should be even with top of KD Bracket. (See fig. 1) 4. Once back is properly seated onto 2. Carefully guide upholstered back onto the mechanism insert the threaded knob thru mechanism inserting both "bayonet links" at "bayonet link", 'ED Bracket" and steel tube. the same time thru cutouts in vinyl. Secure hand tight. 3. Push down on the back until the mechanism "bayonet links" are properly engaged into the 5. Remove tape lower upholstery skirt and secure to Velcro. Upholstered Back Upholstered Skirt Threaded Knobs Upholstered Back’s KD Brackets Steel Tube Mechanism’s Bayonet Links Bracket and Link to be even Threaded Knob thru large hole in Bayonet Link KD Bracket Bayonet Link 4 566DG Ortho Biotic Clinical Care® Recliner Operating Instructions CASTER OPERATION (FRONT) Tread Lock Pedal NOTE: This chair is equipped with four casters for improved maneuverability. The front casters are equipped with tread locks. To Lock: Step on the back edge of the black pedal until it latches and stays down. Figure 5 To Unlock: Step on the top edge of the pedal. To lock swivel CASTER OPERATION (REAR) To unlock wheel NOTE: The chair is equipped with four casters for improved maneuverability. Right rear caster is also equipped with locking features. Swivel lock will aid the chair in rolling straight. To lock wheel Lock: To prevent the rear casters from swiveling and wheel turning, step on the rear pedal of the caster until it latches. Figure 4 Armrest Unlock: Step on middle button to unlatch. TABLE OPERATION To Raise: Raise table all the way up and slide in toward the armrest until tabs engage slots in mount bracket. Press down lightly on table to ensure lock tabs are engaged. To Lower: Lift table up until tabs disengage slots and pull table away from armrest. Lower table to self-storing position. Table (Disengaged Position) 3/8 Clevis Pin Attachment Table Mount Bracket Tabs engage into slots on table mount bracket Table (Engaged Position) Table (Stored Position) SIDE PANEL REMOVAL To Remove: Grasp upholstered side panel at back of panel and pull sharply out from chair until locking clips release side panel. Side Panel To Install: Insert side panel into chair frame by lining up side panel clips with tubes on frame and pushing firmly. Drop Arm Pull Button (Behind Table) 566DG Ortho Biotic Clinical Care® Recliner Operating Instructions 5 SEAT POSITIONING Reclining by Patient: Place hands on armrest and push body against chair's back to recline yourself to desired position. To bring yourself up, place hands on armrest and pull yourself up while leaning your body forward away from the chairs back. Reclining by Attendant: Standing on either side of the chair, grasp the armrest with one hand and push handle with the other hand. Push back on push handle to recline and pull forward to raise the chair. Upright Position Infinite Position Between TV and Full Recline TV Position TRENDELENBURG POSITION: Standing on either side of the chair, grasp the armrest with one hand while holding the recliner back with the other. With your foot, push down on the release bar while gently pushing down with your hand on the recliners back until it comes to a stop. To bring chair out of Trendelenburg, stand on either side of the chair, grasp the armrest with one hand and push handle with the other hand and pull forward on the push handle. Trendelenburg Position 6 566DG Ortho Biotic Clinical Care® Recliner Operating Instructions NOTES U.S.A., Corporate Headquarters: Graham-Field Health Products 2935 Northeast Parkway Atlanta, Georgia 30360 telephone: 800-347-5678, 770-447-1609 fax: 800-726-0601, 678-291-3232 http://www.grahamfield.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Page Count : 8 Producer : QuarkXPress(tm) 6.5 Create Date : 2005:06:02 17:08:26 X Press Private : %%DocumentProcessColors:.%%EndComments Title : 566DG Creator : QuarkXPress(tm) 6.5EXIF Metadata provided by EXIF.tools