Lumi United Technology MCCGQ11LM Window and Door Sensor User Manual

Lumi United Technology Co., Ltd Window and Door Sensor Users Manual

Users Manual

Download: Lumi United Technology MCCGQ11LM Window and Door Sensor User Manual
Mirror Download [FCC.gov]Lumi United Technology MCCGQ11LM Window and Door Sensor User Manual
Document ID3246098
Application IDASoZ7zJJkBiqtHT+geAUHQ==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize32.55kB (406857 bits)
Date Submitted2017-01-04 00:00:00
Date Available2017-01-04 00:00:00
Creation Date2016-12-30 08:55:02
Producing SoftwareMicrosoft® Word 2016
Document Lastmod2016-12-30 08:55:02
Document TitleUsers Manual
Document CreatorMicrosoft® Word 2016
Document Author: Tom

The Door and Window Sensor User’s Manual
Introduce
Aqara’s Door/Window Sensor (DWS) is a smart device featuring low power
consumption, small size, and cost-efficiency, utilizing the ZigBee© wireless protocol. It is
powered by a CR1632 battery, and complies with ZigBee’s HA1.2 (Home Automation)
standard. The DWS communicates with the Aqara multi-functional gateway.
1. This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may
cause undesired operation.
2. Changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance
20cm
between the radiator & your body.
Parameter
Product Model: MCCGQ11LM
Product Size: 41x22x11mm
Battery Type: CR1632
Detect Range :~22 mm
Operation Temperature:- 10℃-+ 50℃
Operation Humidity: 0-95% RH,No Condensation
Execution standard: Q/QLML003-2015
Installation Method:
Effective distance validation: Click the reset button on the OS sensor in selected sensor
installation location, it will be effective communication between device and gateway if the
gateway to prompt.
Step 1: Tear off glue stick protective film
Step 2: Please align install tags
Step 3: Paste respectively on the door or window (advice body fixed installed in opening
and closing area surface, magnet installed in active surface, installation clearance under
the Windows and doors closed less than 22 mm).Please make sure this equipment
installed and operated with minimum distance 20cm between your body.
*The surface of the paste must be kept clean and dry
*Please avoid falls when installation, easy to damage the sensor body.
Step 4: After connected with the gateway, you can monitoring the status of doors and
windows through the APP.
Button Function and LED light indication
No
Function
State
Operation
Join network
If the DWS is not joined with the network:
Press and Hold the reset button for 3
seconds then the DWS initiates a request to
join the network.
Press and hold the
reset button for 3
seconds
Reset
The DWS may or may not be joined to the
network: Press the reset button and the
device will restart.
Press and release the
reset button for a short
time ( <1 second)
Check the
network state
When the DWS is joined to the network: the
DWS will transmit a data request message,
if the gateway receives the message, it will
ring “ding-dong’ after receiving the
message, otherwise not.
Press and release the
reset button for a short
time ( <1 second)
Actuating DWS by joining / separating the magnet:
No
Function
State
Operation
Send closed
message
After
joining the
network
Bring the magnet within Xmm of the DWS body
Send open
message
After
joining the
network
Separate the magnet more than Xmm from the DWS
body
Definition of LED light indication
Operation
Press the reset button for a
short time
Press and hold the reset
button for 3 seconds, until
light blinks, then release it
Condition and state
Led indication
If DWS is not linked to the network
LED blinks once quickly
If the joining operation has finished
and succeeded.
LED blinks 3 times
If the joining operation has finished
and failed
LED lights up for 1
second
If the sensor receives a response
from gateway indicating the sensor
was already linked to the network
LED blinks twice
If the sensor has joined the network or
not, it will disconnect from the
network, and initiate the joining
operation again
Upon successfully
joining the network, the
LED blinks 3 times.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 3
Language                        : zh-CN
Tagged PDF                      : Yes
XMP Toolkit                     : 3.1-701
Producer                        : Microsoft® Word 2016
Creator                         : Tom
Creator Tool                    : Microsoft® Word 2016
Create Date                     : 2016:12:30 08:55:02+08:00
Modify Date                     : 2016:12:30 08:55:02+08:00
Document ID                     : uuid:0E4D93B0-7A17-4D66-904A-77DB5F10AD56
Instance ID                     : uuid:0E4D93B0-7A17-4D66-904A-77DB5F10AD56
Author                          : Tom
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AKIT-MCCGQ11LM

Navigation menu