Lutron Electronics 0038 Tabletop Radio Frequency Key Pad Control User Manual Aurora Repl Dimmer Inst qxp

Lutron Electronics Company Inc Tabletop Radio Frequency Key Pad Control Aurora Repl Dimmer Inst qxp

Usres Manual

Lutron Electronics Co., Inc.7200 Suter RoadCoopersburg, PA  18036-1299, U.S.A.Made and printed in the U.S.A.  2/06  P/N 044-108  Rev. AFCC InformationNote: This equipment has been tested and found to comply with the limits fora Class B digital device, pursuant to Part 15 of the FCC rules. These limits aredesigned to provide reasonable protection against harmful interference in a res-idential installation. This equipment generates, uses and can radiate radio fre-quency energy and, if not installed and used in accordance with the instruc-tions, may cause harmful interference to radio or television reception. However,there is no guarantee that interference will not occur in a particular installation.If this equipment does cause harmful interference to radio or television recep-tion, which can be determined by turning the equipment off and on, the user isencouraged to try to correct the interference by one or more of the followingmeasures: • Reorient or relocate the receiving antenna.• Increase the seperation between the equipment and receiver.• Connect the equipment into an outlet on a circuit different from that towhich the receiver is connected.• Consult the dealer or an experienced radio/TV technician for help.Caution: Changes or modifications not expressly approved by LutronElectronics Co. could void the user’s authority to operate this equipment.Operation is subject to the following: (1) This device may not cause harmfulinterference, and (2) this device must accept any interference received, including interference that may cause undesired operation.Limited Warranty(Valid only in the U.S., Canada, Puerto Rico, and the Caribbean.)Lutron will, at its option, repair or replace any unit that is defective in materialsor manufacture within one year after purchase. For warranty service, return unitto place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA18036-1299, postage pre-paid .THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES,AND THE IMPLIED WARRANTY OF MERCHANTABILITY IS LIMITED TOONE YEAR FROM PURCHASE. THIS WARRANTY DOES NOT COVER THECOST OF INSTALLATION, REMOVAL OR REINSTALLATION, OR DAMAGERESULTING FROM MISUSE, ABUSE, OR IMPROPER OR INCORRECTREPAIR, OR DAMAGE FROM IMPROPER WIRING OR INSTALLATION.THIS WARRANTY DOES NOT COVER INOPERABILITY RESULTING FROMINTERFERENCE, INCORRECT INSTALLATION, OR ENVIRONMENTALFACTORS. THIS WARRANTY DOES NOT COVER INCIDENTAL OR CONSE-QUENTIAL DAMAGES. LUTRON’S LIABILITY ON ANY CLAIM FOR DAM-AGES ARISING OUT OF OR IN CONNECTION WITH THE MANUFACTURE,SALE, INSTALLATION, DELIVERY, OR USE OF THE UNIT SHALL NEVEREXCEED THE PURCHASE PRICE OF THE UNIT.This warranty gives you specific legal rights, and you may also have other rightswhich vary from state to state. Some states do not allow limitations on how longan implied warranty lasts, so the above limitation may not apply to you. Somestates do not allow the exclusion or limitation of incidental or consequentialdamages, so the above limitation or exclusion may not apply to you.These products may be covered under one or more of the following U.S.patents: 4,835,343; 4,954,768; 5,248,919; 5,399,940; 5,637,930; 5,736,965;5,798,581; 5,838,226; 5,848,054; 5,905,442; 5,982,103; 6,687,487; D353,798and corresponding foreign patents. U.S. and foreign patents pending. Lutron, Fassada, and the sunburst logo are registered trademarks and AuroRAis a trademark of Lutron Electronics Co., Inc.© 2006 Lutron Electronics Co., Inc.Technical AssistanceIf you have questions concerning the installation or opera-tion of this product, call the Lutron Technical SupportCenter. Please provide exact model number when calling.+1.800.523.9466 (U.S.A., Canada, and the Caribbean)Other countries call +1.610.282.3800Fax +1.610.282.3090Visit our web site at www.lutron.comImportant Notes11..  Caution::  To avoid overheating and possible damage toother equipment, do not use dimmers to control recep-tacles, fluorescent lighting fixtures, motor-operated ortransformer-supplied appliances.22..Use dimmers with 120V incandescent lighting fixturesonly. Do not use with low-voltage transformers. 33..Install in accordance with all national and local electricalcodes.44..When there is no ground wire or a way to connect thewallbox to ground within the wallbox then the NEC®2002, Article 404-9 allows a dimmer without a ground-ing connection to be installed as a replacement, as longas a plastic, noncombustible wallplate is used. For thistype of installation, cap or remove the green groundwire on the dimmer and use an appropriate wallplatesuch as Lutron’s Fassada®series wallplates.55..Do not paint dimmers or wallplates.66..The total wattage of all light bulbs controlled by eachdimmer must be between 50 and 600 watts. 77..Dimmers work with most incandescent light bulbs.Dimmers may not work with dioded light bulbs (SylvaniaCAPSYLITE DESIGNER 16TM or Philips PAR-16TM).88..Operate system in temperatures between 0 °C (32 °F) and 40 °C (104 °F).99..Dimmer may feel warm to the touch during normaloperation.1100..Recommended wallbox depth is 2 1/2" minimum.1111..single-pole circuit three-way circuitfour-way circuit1122..When combining dimmers in the same wallbox, thedimmer’s load capacity must be reduced.1133..Wire PreparationTrim or strip wallbox wires to the lengthindicated by the strip gauge on the backof the dimmer. Push-in: Insert wires fully. Use #14 AWGsolid copper wire only. For aluminumwire, consult an electrician. DO NOT usestranded or twisted wire.Screw Terminals: Tighten securely. Screwterminals are for use with solid copperwire only. For aluminum wire, consult anelectrician. DO NOT use stranded or twisted wire.1144..Service SwitchPull service switch out to open position to replace lightbulbs.  Push service switch in after new bulb isinstalled.Installation Instructions forReplacement DimmerRead all instructions completely before installation.Incandescent / 120 V HalogenDimmerAR-6D120 V 50/60 Hz  600 WPossible Cause• Front Accessible Service Switch (FASSTM) on Dimmer is pulled out to theOFF position.• Light bulb(s) burned out.• Breaker is OFF or tripped.• Dimmer is out of RF range.• Dimmer not activated to system.• Keypad not activated to system.• Miswire–check wiring with 3-way or 4-way diagram on page 1.• Dimmer is in 4-way location–move Dimmer to 3-way location.TroubleshootingSymptomLight does not turn ON.Dimmer does not respond toKeypad button press.Dimmer does not switch from 3-waylocation.Follow the load capacities in table below for multi-ganged dimmers.singlegang600Wmaxdoublegang500Wmaxtriple gang400Wmaxdouble gang        triple gangservice switchopenservice switchclosedHot120V60HzDimmerGround GroundNeutralLight3-waySwitchHot120V60HzDimmerGroundNeutralLightHot120V60HzDimmer 3-waySwitchGround Ground GroundNeutralLight4-waySwitch1
Installing a Replacement Dimmer2 3Install replacement dimmerA. Note which wire(s) are connected to each terminal. Thereplacement dimmer will be installed identically.B. Disconnect the wires from the dimmer.4Uninstall existing dimmerWARNING: Power mustbe turned off for yoursafety.123Turn power off at circuit breaker or remove fuse Turn power on at circuit breaker or replace fuseConnect the wires to the terminals on the replacement dimmerin the same configuration they were connected to the old dim-mer.6Mount dimmer and replace wallplate51. Enter Device Replacement: Press and hold the Advanced but-ton (on the Central Antenna) for approximately 3 seconds. TheAdvanced LED will be on solid  during the press until the hold isdetected. When the hold is detected, the Advanced LED willflash slowly.2. Dimmers that are already in the System will flash the lights con-nected to each. The Master Control will have the following LEDfeedback: LED flashing corresponds to a Dimmer present andLED off corresponds to a Dimmer not present. Press andRelease the Master Control button that corresponds to theDimmer not present.3. Press and hold the button on the Replacement Dimmer forapproximately three seconds. Upon successful replacement,the Dimmer will start flashing its lights and the selected Keypadbutton will flash its LED.4. Exit Device Replacement: Press and hold the Advanced button forapproximately 3 seconds. The Advanced LED will turn off and theDimmer will stop flashing its lights.5. Dimmer now works in System.Remove wallplate and existing dimmer. Do not disconnectwires. Activating the Replacement Dimmer in your system

Navigation menu