Lutron Electronics 0055 Electronic control with RF communication User Manual
Lutron Electronics Company Inc Electronic control with RF communication
User Manual
StanzaTM StanzaTM Keypads SZ-2B, SZ-3B, SZ-4B, SZ-5B, SZ-3/1B Installation Instructions 120 V Please Read Before Installing 50 / 60 Hz 0.5 W Installation Caution! Locate and remove fuse or lock circuit breaker in the OFF position before proceeding. Wiring with power ON may result in personal injury or death. SZ-2B SZ-3B SZ-5B SZ-4B SZ-3/1B Important Notes Install in accordance with all local and national electrical codes. Caution! These controls must not be used to control equipment that is not visible from every control location. They must also not be used to control equipment that could create hazardous situations such as entrapment if operated accidentally. Examples of such equipment which must not be operated by these controls include (but are not limited to) industrial doors, microwave ovens, heating pads, etc. It is the installer’s responsibility to ensure that the equipment being controlled is visible from every control location and that only suitable equipment is connected to these controls. Environment: Ambient operating temperature: 32 to 104 °F (0 to 40 °C), 0 to 90% humidity, non-condensing. Indoor use only. Spacing: If mounting one control above another, leave at least 4½ in. (114 mm) vertical space between them. Faceplates: Use Lutron Stanza faceplates for best color match and aesthetic appearance. Do not paint controls or faceplates. Cleaning: To clean, wipe with a clean damp cloth. Do not use any chemical cleaning solutions. Wallboxes: Lutron recommends using 3.5 in. (89 mm) deep wallboxes for easier installation. RF Device Placement: RF keypads must be located within 20 feet (6 m) of an RF signal repeater or a device configured as a repeater. Stanza RF keypads cannot control any device in the system until they are addressed and programmed. When powered and unaddressed, they turn on their button backlights to indicate proper operation. 1. T urn power OFF at fusebox or circuit breaker. 2. P repare wires. When making wire connections, follow the recommended strip lengths and combinations for the supplied wire connector. Note: Wire connectors provided are suitable for copper wire only. Wire Connector: • Strip insulation 3/8 in. (9.5 mm) for #14 AWG (1.5 mm2) wire • Strip insulation 1/2 in. (12.7 mm) for #16 or 18 AWG (1.0 mm2 or 0.75 mm2) wire Twist wire connector tight. Operation Mounting Diagram Faceplate adapter mounting screws Wallbox Included: Control Wire Connectors (2) Faceplate/adapter purchased separately. Keypad Buttons Can be programmed to control one or more zones or contact closure outputs Buttons are backlit for easy location in a darkened room. Mounting Screws (2) Returning the Dimmer/Switch to Factory Settings 1. Triple-tap a button on the keypad quickly (within 1 second). 2. Press and hold the same button on the keypad for 5 seconds (until the status LEDs flash) . 3. Triple-tap the same button on the keypad quickly again. Notes •R eturning to factory settings will clear all programming from the keypad, and will prevent it from being controlled over RF. •A fter being returned to factory defaults, the device will need to be readdressed as part of a system. 3. W ire controls as follows: a. Connect the black control wire to the Hot/Live wire coming from the panel. b. Connect the white control wire to the Neutral wire coming from the panel. Hot/ Live Black 120 V 50 / 60 Hz Neutral Status LEDs Indicate current scene selected; all glow softly as night lights when scene is not selected Control mounting screws White Troubleshooting Guide 4. P ush all wires back into the wallbox and loosely fasten the control to the wallbox using the control mounting screws provided. Do not pinch the wires. 5. Attach Lutron Stanza faceplate adapter and faceplate. a. Install faceplate adapter onto front of control(s). b. Tighten control mounting screws until faceplate adapter is flush to wall (do not over-tighten). c. Snap faceplate onto faceplate adapter, and verify that control is aligned properly. d. If control(s) is (are) misaligned, loosen mounting screws appropriately. 6. Restore power. Check for correct local operation (see Operation). Keypad will not control a remote device until it is addressed. Symptom Cause and Action Keypad LEDs do not light Power not present • Circuit breaker OFF or tripped. Perform short circuit check. Wiring error • Check wiring to be sure it agrees with installation instructions and wiring diagrams. Lights do not respond to a button press Improper programming • Check programming in the Stanza software. Out of RF range • Ensure device is within 20 feet (6 m) of another device configured as a repeater. All status LEDs flash when each keypad button is pressed Keypad is not addressed to the system • Address device as part of a Stanza system. Technical support: U SA, Canada, Caribbean: 1.800.523.9466 Mexico: +1.888.235.2910 Central/South America: +1.610.282.6701 Warranty: 1-year limited warranty standard. 2-year parts and labor warranty, with 8-year pro-rated parts replacement on commissioned systems. FCC Information Note: This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules. Operation is subject to the following: (1) This device may not cause harmul interference, and (2) this device must accept any interference received, incouding interference that may cause undesired operation. These products may be covered under one or more of the following U.S. patents: 5,248,919; 5,637,930; 5,838,226; 5,848,054; 5,905,442; 6,687,487; 6,803,728; and corresponding foreign patents. U.S. and foreign patents pending. Lutron and the sunburst logo are registered trademarks and FASS and Stanza are trademarks of Lutron Electronics Co., Inc. © 2008 Lutron Electronics Co., Inc. Lutron Electronics Co., Inc. Made and printed in the U.S.A. P/N 030-995 Rev. A 6 /08
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Tagged PDF : Yes XMP Toolkit : 3.1.1-111 Instance ID : uuid:11c93947-9c37-4fd8-9efe-b9f8e3c921fe Document ID : adobe:docid:indd:9700f181-3320-11dd-b82a-ac4c19f22906 Rendition Class : proof:pdf Derived From Instance ID : af4e7c0a-331a-11dd-b82a-ac4c19f22906 Derived From Document ID : adobe:docid:indd:192b05e9-3237-11dd-b82a-ac4c19f22906 Manifest Link Form : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream Manifest Placed X Resolution : 300.00, 300.00, 72.00, 300.00, 300.00, 300.00, 72.00 Manifest Placed Y Resolution : 300.00, 300.00, 72.00, 300.00, 300.00, 300.00, 72.00 Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches Manifest Reference Instance ID : uuid:F01E7A69A33D11DC9AE4F26D9E047CA8, uuid:F01E7A63A33D11DC9AE4F26D9E047CA8, uuid:6081411C76C5DA11BDC9A93607A846D6, uuid:62BB6CB7A33D11DC9AE4F26D9E047CA8, uuid:475B50FEA33D11DC9AE4F26D9E047CA8, uuid:F762C72B286011DDB231FA88107FC6E4, uuid:6081411C76C5DA11BDC9A93607A846D6 Manifest Reference Document ID : uuid:F01E7A68A33D11DC9AE4F26D9E047CA8, uuid:F01E7A62A33D11DC9AE4F26D9E047CA8, uuid:5F81411C76C5DA11BDC9A93607A846D6, uuid:62BB6CB6A33D11DC9AE4F26D9E047CA8, uuid:475B50FDA33D11DC9AE4F26D9E047CA8, uuid:CE14146E286011DDB231FA88107FC6E4, uuid:5F81411C76C5DA11BDC9A93607A846D6 Create Date : 2008:06:24 11:20:41-04:00 Modify Date : 2008:06:24 11:21:27-04:00 Metadata Date : 2008:06:24 11:21:27-04:00 Creator Tool : Adobe InDesign CS2 (4.0.5) Thumbnail Format : JPEG Thumbnail Width : 256 Thumbnail Height : 256 Thumbnail Image : (Binary data 11619 bytes, use -b option to extract) Format : application/pdf Producer : Adobe PDF Library 7.0 Trapped : False Page Count : 1 Creator : Adobe InDesign CS2 (4.0.5)EXIF Metadata provided by EXIF.tools