Lutron Electronics 0064 Visor Control Receiver User Manual 1
Lutron Electronics Company Inc Visor Control Receiver 1
Contents
- 1. User Manual 1
- 2. User Manual 2
User Manual 1
English Installation Instructions Please Read Before Installing Visor Control Receiver: RR-VCRX 9V 300 mA DC Adapter: T120-9DC-3 Input: 120 V 60 Hz 6.5 W Output: 9 V 300 mA Typical Power Consumption*: 1.6 W Visor Control Transmitter: LR-3B-H 3V 10 mA Dimensions Receiver (front view) Features • 2 Contact Closure Inputs (CCI) for integration with other systems and 1 CCI for security systems. • 4 Contact Closure Outputs (CCO) to control up to 4 momentary garage doors or motorized gates. • Up to 10 Transmitters can be used with a Receiver. • Each output can be controlled locally at the Receiver or remotely by a Transmitter • Includes pre-printed and blank labels for naming scenes / buttons. Installation of a Visor Control Transmitter 1. Attach the visor clip to the Transmitter as shown in the Mounting Diagram. 2. Mount the Transmitter onto a vehicle’s visor. *Typical Power Consumption test conditions: two LEDs on (two presets active), Receiver powered by the 9 V supplied, no Contact Closure Outputs or Contact Closure Inputs active. Technical Assistance: U.S.A. / Canada: 1.800.523.9466 Mexico: +1.888.235.2910 Other Countries: +1.610.282.3800 24 hours a day, 7 days a week. Lutron Electronics Co., Inc. 7200 Suter Road Coopersburg, PA 18036-1299 Made and printed in the U.S.A. 8/09 P/N 044-161 Rev. A Security Input 0.23 (5.8) Outputs Keypad 5.25 (133.4) Visor Transmitter 2.72 (70) Learn 1 - Output 1 C - Common 1 2 - Output 2 C - Common 2 Security - Full Flash 3 - Output 3 C - Common 3 4 - Output 4 C - Common 4 Input 2 - 2 Input 1 - 1 0.31 (7.9) dia. 0.19 (4.8) dia. 9V DC Inputs Full 1 2 Flash C Symptom Probable Cause and Action Dimmers, keypads, shades/drapes, security system, garage doors or motorized gates do not respond to the Visor Control Receiver or Transmitter. Power Not Present • Ensure that the power supply cord is plugged into a wall outlet and the power jack on the Receiver. • Circuit Breaker is OFF or tripped. Reset or turn on circuit breaker. 9V Visor Control Receiver Power Contact Closure Outputs (CCO) Max Voltage / Current: See Relay Contact Ratings below. Listed Class 2 / Certified PELV Minimum Pulse Time: 500 ms (all inputs) Flash Mounting hole detail Contact Closure Inputs (CCI) at 2 mA ON saturation: <1 V OFF leakage: <1 µA at 9 V Minimum Pulse Time: 40 ms Common - C Full Outputs 1 C 2 C 3 C 4 C Mounting holes 3.75 (95.3) 4.25 (108) Transmitter (front view) Contact Closure Terminal Blocks Use Class 2 cable Maximum 1,000 ft (305 m) Each terminal holds up to one 16 AWG (1.0 mm2) or two 18 AWG (0.75 mm2) or smaller wire. Power Jack (to DC adapter) Model: T120-9DC-3 (NEC® Class 2 / IEC PELV) Transmitter (side view) 3.19 (81) 0.75 (19) Vertical Voltage Resistive Load Inductive Load Up to 30 V 1A 0.2 A Contact Closure Inputs not wired correctly. • Refer to the Connection Diagram for proper wiring. Up to 30 V 1A 0.1 A Up to 60 V 0.5 A Do not use. Contact Closure Outputs not wired correctly. • Refer to the Connection Diagram for proper wiring. Dead, low, or no batteries in the Transmitter. • Install new batteries in the Transmitter (CR2032) The Transmitter is not communicating with the Receiver. Normal Operation Horizontal Ceiling Visor Control Receiver Input LEDs Display which CCIs are active. Inputs Input Buttons Press to test CCI programming. Security Input Full Wall #6 (M3) screw recommended (included) Flash Outputs Keypad Inputs Security Input Full Visor Transmitter Learn Flash Visor Control Receiver Power 9V DC Level Surface 1.06 (26.9) Transmitter (back view) Vehicle visor Inputs Full 1 2 Flash C Outputs 1 C 2 C 3 C 4 C Outputs Keypad Learn LED Flashes to indicate that the Receiver is in Learn mode. Visor Control Transmitter The Transmitter is not programmed correctly. the system Setup Guide to program the Transmitter. • See Transmitter is not within specified RF range. • Wait until the Transmitter is within 150 ft (46 m) of the Receiver before pressing a button on the Transmitter. Dead, low, or no batteries in the Transmitter. • Install new batteries in the Transmitter (CR2032). Security Input LEDs Display which Security option has been selected. Security Input Buttons Press and hold to test Security programming. Output LEDs Display which CCOs are active. Output Buttons Press to test CCOs. System devices are not within specified RF range. • Ensure that dimmers, keypads and shades/drapes are within 30 ft (9 m) of a repeater. • Verify that all repeaters are within 60 ft (18 m) of another repeater. • Make sure that the Receiver is within 30 ft (9 m) of a repeater. • Wait until the Transmitter is within 150 ft (46 m) of the Receiver before pressing a button on the Transmitter. The Transmitter is not programmed correctly. • See the system Setup Guide to program the Transmitter. Mounting Diagram Receiver (side view) System devices are not programmed correctly. • Program all devices according to the system Setup Guide. Receiver is not programmed correctly. • See the system Setup Guide to program the Receiver. Relay Contact Ratings 1.5 (38) Installation of a Visor Control Receiver 1. Find a suitable location for the Receiver either near a security sytem panel or above a garage door opener and within 30 ft (9 m) of a repeater. For more information regarding the proper placement of a Receiver in a system see the system Setup Guide located at the website listed above. 2. Mount vertically or horizontally, as shown in the Mounting Diagram, using two #6 (M3) screws (included). When mounting, allow 7 in (177.8 mm) clearance for the antenna and ensure convenient access to the contact closures and front buttons. In order to achieve proper RF performance, do not mount unit in a metal enclosure. 3. Attach the DC adapter cord to the power jack on the Receiver and insert the DC adapter plug into a 120 V 60 Hz receptacle. 0.63 (16) Inputs Important Notes nvironment Visor Control Receiver: Ambient operating temperature: 32 °F to 140 °F (0 °C to 60 °C), 0% to 90% humidity, non-condensing. Indoor use only. Visor Control Transmitter: Ambient operating temperature: -40 °F to 235 °F (-40 °C to 113 °C), 0% to 90% humidity, non-condensing. Meets the Society of Automotive Engineers (SAE) temperature standards. Codes Install in accordance with all local and national electrical codes. Cleaning To clean, wipe with a clean damp cloth. DO NOT use any chemical cleaning solutions. Visor Control Receiver DC Adapter Power NOTICE - Using a DC adapter not rated at the proper specifications could damage the Receiver and possibly overheat the DC adapter. Use only the Lutron® DC adapter listed above. Visor Control Transmitter Battery Power A Transmitter uses two (2) CR 2032 batteries (included). Keep batteries out of reach of children. Using improper batteries could damage the Transmitter. DO NOT dispose of the batteries in normal household waste. Please recycle batteries, take to a battery disposal facility, or contact your local waste disposal provider regarding local restrictions on the disposal or recycling of batteries. RF Device Placement The Receiver must be within 30 ft (9 m) of an RF signal repeater. The typical operating distance between a Receiver and a Transmitter is 150 ft (46 m). Programming For programming instructions, see the system Setup Guide provided with the system or visit the website listed above. Receiver (bottom view) 6.25 (158.8) Use these instructions to install the model numbers listed above. For system setup instructions and tools visit: www.lutron.com/radiora2 Troubleshooting Guide Connection Diagram Measurements are in inches (mm). LEDs on the Receiver do not turn on when it is powered up. Improper AC adapter used. • Use the DC adapter provided with the Receiver. Top Keypad LED on the Receiver flashing rapidly. Improper adapter used. • Use the DC adapter provided with the Receiver. Note: Refer to the system Setup Guide for additional troubleshooting suggestions. Remove all Visor Control Transmitters from the Visor Control Receiver Keypad Buttons Press to test keypad programing. Visor Transmitter Learn Learn Button Press and hold for 10 seconds to enter Learn mode. Labels Place pre-printed or custom labels in depression to name buttons. Keypad LEDs Display status of lights and shades / drapes programmed to the Keypad buttons. adapter Visor Control Transmitter Buttons Press to activate functions remotely. These products may be covered under one or more of the following U.S. patents: 5,838,226; 5,848,054; 5,905,442; 6,687,487; 6,803,728 and corresponding foreign patents. U.S. and foreign patents may be pending. Lutron, RadioRA and the sunburst logo are registered trademarks and RadioRA 2 is a trademark of Lutron Electronics Co., Inc. © 2009 Lutron Electronics Co., Inc. Note: Removing the Transmitters from the Receiver will remove the capability to activate functions on the Receiver remotely but will not remove programming from the Receiver. The Transmitters will need to be reprogrammed to a Receiver according to the system Setup Guide. 1. Triple tap and hold the Learn button on the Receiver. DO NOT release the button after the third tap. 2. Keep the button pressed on the third tap until the Learn LED starts to flash slowly (approximately 3 seconds). 3. Release the button and immediately triple tap it again. The Learn LED will flash quickly. When the LED stops flashing, all of the Transmitters have been removed from the Receiver. Returning a Visor Control Receiver to Factory Settings Note: Returning the Receiver to factory settings will erase all system programming from the Receiver and will require the Receiver and all Transmitters to be reprogrammed into a system according to the system Setup Guide. 1. Triple tap and hold any button (except the Learn button) on a Receiver. DO NOT release the button after the third tap. 2. Keep the button pressed on the third tap until the LED(s) start to flash slowly (approximately 3 seconds). 3. Release the button and immediately triple tap it again. The LEDs will flash quickly. When the LEDs stop flashing, the Receiver has been returned to factory settings. Warranty: For warranty information, please see the Warranty enclosed with the product, or visit www.lutron.com/resiinfo.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No XMP Toolkit : 3.1-702 Instance ID : uuid:fa0c504d-ea64-4574-9262-3f050e5528c8 Document ID : adobe:docid:indd:24ed3ede-aded-11de-ab7f-9ab6f81e12a0 Rendition Class : proof:pdf Derived From Instance ID : b77c6580-addc-11de-ab7f-9ab6f81e12a0 Derived From Document ID : adobe:docid:indd:b77c6579-addc-11de-ab7f-9ab6f81e12a0 Manifest Link Form : ReferenceStream, ReferenceStream Manifest Placed X Resolution : 72.00, 72.00 Manifest Placed Y Resolution : 72.00, 72.00 Manifest Placed Resolution Unit : Inches, Inches Manifest Reference Instance ID : uuid:293040644CACDE119C1DA7BE78A4994A, uuid:DA55EB382F13DE11BC0CA12883387E6B Manifest Reference Document ID : uuid:DA954BFBDBA6DE118E5386E6F67080A9, uuid:D955EB382F13DE11BC0CA12883387E6B Create Date : 2009:10:01 09:52:06-04:00 Modify Date : 2009:10:01 10:09:14-04:00 Metadata Date : 2009:10:01 10:09:14-04:00 Creator Tool : Adobe InDesign CS3 (5.0.4) Thumbnail Format : JPEG Thumbnail Width : 256 Thumbnail Height : 256 Thumbnail Image : (Binary data 12816 bytes, use -b option to extract) Format : application/pdf Producer : Adobe PDF Library 8.0 Trapped : False Page Count : 1 Creator : Adobe InDesign CS3 (5.0.4)EXIF Metadata provided by EXIF.tools