Lutron Electronics 0074 RF Theromstat User Manual
Lutron Electronics Company Inc RF Theromstat
Contents
- 1. user manual
- 2. manual
user manual
Mounting Diagram English seeTemp™ Wall Display Installation Instructions Wallplate Adapter Mounting Screws LRD-WST-F, LRD-WST-C 24 V or 120 V 50 / 60 Hz 0.1 A Typical Power Consumption*: 1 W Please Read Before Installing Adapter Mounting Wallplate Screws Environment: Ambient operating temperature: 32 °F to 104 °F (0 °C to 40 °C), 0 to 90% humidity, non-condensing. Indoor use only. 3. Exit Add Mode: Press and hold the “Add” button on any Repeater for 3 seconds until “Add” LED begins to rapid-flash. After LED turns off (can take up to 30–60 seconds), system has exited Add Mode. eco Wallplates: Use only Lutron® wallplates with these devices. The mechanical design of the seeTemp Wall Display is NOT compatible with non-Lutron wallplates. Non-Lutron wallplates will NOT sit flush against the wall. Claro® and Satin Colors® wallplates are strongly recommended for best color match and clean aesthetic appearance. Do not paint controls, buttons, or wallplates. Cleaning: To clean, wipe with a clean damp cloth. Do not use any chemical cleaning solutions. 4. Test the system: Wallbox a. Set the seeTemp to Heat or Cool mode. seeTemp Wall Display Wallplate adapter and wallplate purchased separately. in (89 mm) deep Installation Room Temperature LEDs Column of LEDs that display the current room temperature. ON ON OFF OFF OFF seeTemp® Wall Display ON RF Device Placement: RF must be located within 30 ft (9 m) of an RF signal repeater. WARNING: Shock Hazard. To avoid the risk of electric shock, locate and remove fuse or lock circuit breaker in the OFF position before proceeding. Wiring with power ON could result in serious injury or death. 1. Turn power OFF at fusebox or circuit breaker. 2. Prepare wires. When making wire connections, follow the recommended strip lengths and combinations for the supplied wire connectors. Note: Wire connectors provided are suitable for copper wire only. • Strip insulation 3/8 in (10 mm) for 14 AWG (1.5 mm2 ). • Strip insulation 1/2 in (13 mm) for 18 AWG (0.75 mm2 ). • Use to join one 14 AWG (1.5 mm2 ) with one 18 AWG (0.75 mm2 ) wires. 3. Wire control. 120 V Wiring Hot/Live Set Temperature LEDs Column of LEDs that display the current set temperature point. Set LED turns off when system is turned off. Probable Cause and Action LEDs on a seeTemp Wall Display don’t light up when the buttons on it are pressed. Power not present at seeTemp Wall Display • Circuit breaker OFF. Turn ON breaker. Incorrect wiring. • Wire the seeTemp Wall Display according to the Installation section. Press to raise the Set temperature. Raise/Lower Rocker Press to lower the Set temperature. 75° 70° 65° eco 60° Heat Cool Auto Off Fan On HVAC controller not controlled by a seeTemp Wall Display and/or temperature is not changing. Eco Button Press to toggle Eco mode on/off. Black Green Auto HVAC equipment does not have enough power and can’t reach setpoint Ground Flip-Down Door Covers the System and Fan buttons. Opens 180°. 70° Fan Buttons Indicates the current fan setting. Button will light up when selected. On – Fan is constantly on. Auto – Fan is on only when Heat/Cool is active. 65° Black Green OFF OFF NOTE: O rientation arrow MUST point UP. OFF Wiring 5. Attach Lutron Claro or Satin Colors wallplate adapter and wallplate (see Mounting Diagram). a. Install the wallplate adapter onto the front of the seeTemp Wall Display. b. Tighten mounting screws until wallplate adapter is flush to wall (do not over-tighten). c. Snap wallplate onto wallplate adapter and verify that the color replacement kit is aligned properly. d. If control(s) are misaligned, loosen mounting screws appropriately. 6. Restore power. ON LUTRON ON White ON eco 60° * 80° *Cap ground wire for 24 V wiring applications. 24 V 50 / 60 Hz 70° 65° eco 60° White LUTRON Programming After installation, the HVAC controller (LR-HVAC) will only function when programmed to a system with a seeTemp™ Wall Display (LRD-WST). For full functionality, the HVAC Controller must be programmed to a RadioRA® 2 Main Repeater (RR-MAIN-REP) and PC software must be used by a Lutron factorytrained installer. For questions on how to become a qualified installer, please contact your local Lutron representative. Temporary Programming 4. Push all wires back into the wallbox and loosely fasten the control to the wallbox using the seeTemp Wall Display mounting screws provided. Do not pinch the wires. See Mounting Diagram below. *Typical Power Consumption test conditions: all backlights on medium intensity, two LEDs on seeTemp Wall Display powered at 120 V Technical Assistance | 24 hours a day, 7 days a week | www.lutron.com U.S.A. / Canada: 1.800.523.9466 | Mexico: +1.888.235.2910 | Other Countries: +1.610.282.3800 Lutron Electronics Co., Inc. 7200 Suter Road | Coopersburg, PA 18036-1299 Printed in the U.S.A. 11/2010 P/N 041-298 Rev. A 6 LEDs on the seeTemp Wall Display flash when any button is pressed. The seeTemp Wall Display is in the Factory Settings mode and has not been configured to work in a system. •F ollow the steps in Programming. Room Temperature LED flashes rapidly. Low battery on Wireless Temperature Sensor. •R eplace battery in Wireless Temperature Sensor. Set temperature LED flashes rapidly. The seeTemp Wall Display is hearing the wired backup sensor and cannot hear Wireless Temperature Sensor. •M ove Wireless Temperature Sensor closer to a repeater. Room LED scrolls up and down. No Wireless Temperature Sensor or wired backup is present. •R eplace battery in Wireless Temperature Sensor. •A dd a Wireless Temperature Sensor. •A dd a wired backup sensor. Room and set LED scrolls up and down when button is pressed. Communication Error. •M ove a repeater closer to a seeTemp Wall Display. Returning a seeTemp Wall Display to Factory Settings Room Set 75° The HVAC controller is not assigned to a seeTemp Wall Display. •F ollow the steps in Programming. There is no power to the device. •E nsure that the device is powered NOTE: O rientation arrow MUST point UP. 120 V 50 / 60 Hz 24 V Common Symptom 80° 75° 24 V from HVAC equipment c. As the temperature changes, the HVAC controller will control the HVAC equipment when required. Temperature may take up to 20 minutes to change in the space Room Set 24 V b. Tap the link button on the Wireless Temperature Sensor. The Temperature will update on the seeTemp. Troubleshooting Guide for seeTemp Wall Display Room Set System Buttons Indicates the current system setting. When selected, buttons will light up according to the following: Heat - Red Cool - Blue Auto - Orange Off - Orange 80° Neutral a. For the HVAC controller, press and hold the Link button for 3 seconds until all LEDs normal-flash (once per second). c. For the Wireless Temperature Sensor, press and hold the Link button for 6 seconds until the hidden LED flashes (once per second). Codes: Install in accordance with all local and national electrical codes. 1⁄ 2 (continued) b. For the seeTemp, press and hold the Eco button for 3 seconds until all LEDs normal-flash (once per second). Important Notes Wallboxes: All seeTemp Wall Display units require a U.S. wallbox. 3 recommended, 2 1⁄ 4 in (57 mm) deep minimum. Temporary Programming 2. Add the devices to the Main Repeater: Since the HVAC system may need to function before a Lutron factory-trained installer is available for programming, temporary programming may be used to provide climate control. To complete the steps below, the following are required: RadioRA 2 Main Repeater (RR-MAIN-REP) within 30 ft of the HVAC controller, seeTemp unit(s), and Wireless Temperature sensor(s). 1. Enter Add Mode: Press and hold the “Add” button on Main Repeater for 3 seconds until green “Add” LED begins to rapid-flash (ten times per second) and repeater beeps. Wait 10 seconds. Returning a seeTemp Wall Display to its Factory Settings will remove the seeTemp Wall Display from the system and erase all programming. Step 1: T riple tap the ECO button on the seeTemp Wall Display. DO NOT release after third tap. Step 2: K eep the button pressed on the third tap until all the status LEDs start to flash slowly (approximately 3 seconds). Step 3: Immediately release the button and triple tap the button again. The status LEDs on the seeTemp Wall Display will flash quickly. The seeTemp Wall Display has now been returned to Factory Settings. Warranty: For warranty information, please see the Warranty enclosed with the product, or visit www.lutron.com/resiinfo
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.0-c006 1.236519, Wed Jun 14 2006 08:31:24 Instance ID : uuid:48ebfde9-711c-49f6-ab36-f8b6b3e58e90 Document ID : adobe:docid:indd:00d6c585-cbca-11df-b307-ced790c13628 Rendition Class : proof:pdf Derived From Instance ID : 00d6c584-cbca-11df-b307-ced790c13628 Derived From Document ID : adobe:docid:indd:178ab69d-cb2b-11df-9ccb-8052682b0a9c Manifest Link Form : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream Manifest Placed X Resolution : 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00 Manifest Placed Y Resolution : 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00 Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches Manifest Reference Instance ID : uuid:7860F4D45062DE119979F126F7D3F84E, uuid:7860F4D45062DE119979F126F7D3F84E, uuid:FC241998C5CBDF119F29A045DABA0B38, uuid:FA81CE76A800DB11AE108EA38A6D00F8, uuid:23299C2BB9D0DF11A96DF1EF5A90DAB2, uuid:3964009A9299DF11AC13F44AC749A36A, uuid:7860F4D45062DE119979F126F7D3F84E, uuid:BFF2EDBAC1D0DF11A96DF1EF5A90DAB2, uuid:7860F4D45062DE119979F126F7D3F84E, uuid:C1F2EDBAC1D0DF11A96DF1EF5A90DAB2, uuid:7860F4D45062DE119979F126F7D3F84E Manifest Reference Document ID : uuid:351EBD1D4C57DE11A4E1FC9FF2836DD1, uuid:351EBD1D4C57DE11A4E1FC9FF2836DD1, uuid:FB241998C5CBDF119F29A045DABA0B38, uuid:F981CE76A800DB11AE108EA38A6D00F8, uuid:22299C2BB9D0DF11A96DF1EF5A90DAB2, uuid:3664009A9299DF11AC13F44AC749A36A, uuid:351EBD1D4C57DE11A4E1FC9FF2836DD1, uuid:1DEC1AA4CCA0DF118BDBD88A2456CD01, uuid:351EBD1D4C57DE11A4E1FC9FF2836DD1, uuid:24299C2BB9D0DF11A96DF1EF5A90DAB2, uuid:351EBD1D4C57DE11A4E1FC9FF2836DD1 Create Date : 2010:12:06 08:20:36-05:00 Modify Date : 2010:12:06 08:20:37-05:00 Metadata Date : 2010:12:06 08:20:37-05:00 Creator Tool : Adobe InDesign CS3 (5.0) Thumbnail Format : JPEG Thumbnail Width : 256 Thumbnail Height : 256 Thumbnail Image : (Binary data 11728 bytes, use -b option to extract) Format : application/pdf Producer : Adobe PDF Library 8.0 Trapped : False Page Count : 1 Creator : Adobe InDesign CS3 (5.0)EXIF Metadata provided by EXIF.tools