Lutron Electronics 0108 Controller User Manual

Lutron Electronics Company Inc Controller

User Manual

Download: Lutron Electronics 0108 Controller User Manual
Mirror Download [FCC.gov]Lutron Electronics 0108 Controller User Manual
Document ID2363070
Application IDo8eh80VI5MjcxAuf2LnBqg==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize130.93kB (1636673 bits)
Date Submitted2014-08-19 00:00:00
Date Available2014-08-19 00:00:00
Creation Date2014-07-30 08:41:10
Producing SoftwareAdobe PDF Library 10.0.1
Document Lastmod2014-07-31 09:59:40
Document TitleUser Manual
Document CreatorAdobe InDesign CS6 (Windows)

Required Components
Project 37 | Installation
041467
Rev. A
07/2014
Part of the Energi TriPak® Family
FC-1 (Project 37
Control Module)
120 – 277 V~ 50 / 60 Hz 1 A
FC-0
(Project 37 Sensor)
12 V- 25 mA
One Project 37 Control Module
Load Status LED
At least one Sensor or Pico® Wireless Control
Raise
Project 37 Control Module with 0 –10 V
Note: Project 37 Control Module can be used without a Sensor
Important Notes: Please read before installing.
For installation by a qualified electrician in accordance with all
local and national electrical codes.
Note: Use copper conductors only.
Check to see that the device type and rating is suitable for the
application.
DO NOT install if product has any visible damage.
If moisture or condensation is evident, allow the product to dry
completely before installation.
Operate between 0 °C and 40 °C, ambient.
0% to 90% humidity, non-condensing.
For indoor use only.
Project 37
Control Module
Install control module directly to fixture or
in junction box nearest the fixture. Install sensor
in ceiling near fixture so as to optimize coverage in the desired area.
Project 37
Control
Module
Sensor
30 ft (9 m)
English
Radio Powr SavrTM
Occupancy/Vacancy Sensor
Project 37 Occupancy/Vacancy and
Daylight Sensor (1 maximum)
30 ft (9 m) max
Pico® Wireless
Control
6 mA maximum for the control lines. Switches up to 1 A total. May be
pre-installed in light fixture.
(10 maximum)
(10 maximum)
Hot (Bla
Start Here
Install Project 37 Control Module
and Sensor
Suggested Installation Location: Close to the
Fixture/Troffer.
Hot (Black)
Green/Yellow
Neutral (White)
Neutral
WARNING! Shock Hazard. May result in serious injury or death.
Turn off power at circuit breaker before installing the unit.
The Project 37 Control Module can be installed in a
fixture/troffer, junction box or marshalling box using the
conduit nut (provided) or with mounting screws (not
provided). Please consult local and national electric
codes for proper installation.
If installing unit inside a junction box, please see
Application Note #423 at
www.lutron.com/TechnicalDocumentLibrary/048423.pdf
B Ideally mount the sensor to the ceiling tile close to the
fixture using the wire form or using the command strips
(included). The 2 communication wires from the sensor
attaches to the control module poke in connectors.
C Once installed, energize the Project 37 Control Module.
Fixture/Troffer
or Junction
Box
Fixture Earth
NEU
Switched Hot (Red)
HOT
Violet
Gray
–
Class 2
•
•
•
Daylight Lens
MAINS
•
•
Consult third-party 0 – 10 V fixtures installation guide for fixture-specific wiring.
PIR Lens
Laser Detection
Lower
Control: 0–10 V- 6 mA
At least one 0 – 10 V Fluorescent Ballast or LED Driver
Toggle
UL 2043 Plenum Rated
•
•
Technical Assistance | 1.800.523.9466 USA, Canada, and the Caribbean | +44.(0)20.7702.0657 Europe | +1.610.282.3800 Others | www.lutron.com
For each fixture, ensure that you have:
The Project 37 sensor mounts to the ceiling surface with a supplied wireform clip.
Two wires connect to the control module and can either be routed through a hole in
the ceiling or across the ceiling surface. DO NOT install on ceilings higher than 12 ft
(3.7 m). The sensor should be installed in a location where it has a good view of the
space that it is meant to cover.
Slide closed end of wire form under
the two retention arms on the back
of the sensor
While continuing to push against the
retention arms, rock the other side of
the wireform down against the sensor
and slide them into place under the
loop retention features
1/2 in (21 mm) Knockout Opening
Conduit Nut
From back of sensor
Pico®
Wireless
Control
Neutral
Install the Sensor
Spring arms
Note: For solid ceilings or
others where the wireform
cannot be utilized, use the
supplied Command strips
to adhere sensor to desired
location on ceiling or fixture.
Push wireform through tile and
bend on the backside of the tile to
complete the mounting.
40 ft (12 m)
All Wireless
Transmitters
must be
installed within
30 ft (9 m) of the
Project 37 Control Module.
Associate Wireless Transmitters to Project 37 Control Module
Sensor Detection Range
Before beginning this step, make sure that there are no other Project 37 Control Modules being set up in the building which are currently in this
association mode.. It is possible that wireless transmitters from other systems can be incorrectly associated to this module.
Ceiling
A Initiate association mode on the Project 37 Control Module by shining a green
laser pointer at the laser detection hole on the sensor until the load attached to
the Project 37 Control Module starts flashing every 2 seconds.
		 Alternatively, press and hold the toggle button for 6 seconds on the Project 37
Control Module to initiate association mode.
B Hold the indicated button on each transmitter
for 6 seconds. The fixture will flash to show that
wireless transmitters have been associated.
To associate another transmitter, repeat steps
4A and 4B.
Default Functionality
9 ft
(2.75 m)
Floor
15 ft
(4.6 m)
15 ft
(4.6 m)
Wireless Controls
9 ft
(2.7 m)
3 ft
(0.9 m)
3 ft
(0.9 m)
9 ft
(2.7 m)
15 ft
(4.6 m)
400 ft2 (37 m2) maximum coverage
area of one sensor whenmounted
on an 9 ft (2.75 m) ceiling
Laser Detection (smallest)
On
All lights 100%
Favorite All lights 50%
Off
All lights off
Link
Test
OR
9 ft
(2.7 m)
3 ft
(0.9 m)
3 ft
(0.9 m)
Green laser specifications:
• Wave output: constant
• Wavelength: 532 nm
• Output power: 5 mW maximum
Lutron Electronics Co., Inc., 7200 Suter Road
Coopersburg, PA 18036-1299 U.S.A.
9 ft
(2.7 m)
15 ft
(4.6 m)
15 ft
(4.6 m)
9 ft
(2.7 m)
3 ft
(0.9 m)
3 ft
(0.9 m)
9 ft
(2.7 m)
15 ft
(4.6 m)
Project 37 Load Control Module |
Programming
Part of the Energi TriPakR Family
041467
Rev. A
07/2014
ALL PROGRAMMING IS OPTIONAL
Set a Favorite Light Level
Technical Assistance | 1.800.523.9466 USA, Canada, and the Caribbean | +44.(0)20.7702.0657 Europe | +1.610.282.3800 Others | www.lutron.com
For Pico® Wireless Controls with a Favorite Button.
A Adjust lights to desired level:
Raise
Lower
Use Raise button “ ” or Lower button “ ” on Pico® wireless control.
Programming is not required for default functionality
• Set a favorite light level
• Set high-end and low-end trim for all fixtures
B Save favorite level:
Press and hold Favorite button for 6 seconds.
The load flashes 3 times to confirm that the set level is saved.
Reset Factory Defaults
Note: In some instances, it may be necessary
to reset the PowPak® Dimming Module and
connected devices back to factory default
settings. Before beginning, make sure that all
devices are connected and powered.
A Triple-tap any button on the PowPak® Dimming
Module and hold until the LED begins to flash
slowly; release button.
B Within 3 seconds of the start of flashing, triple‑tap
the same button again and the LEDs will flash
rapidly indicating that the unit has been reset to
factory defaults.
Note: Any associations or programming
previously set up with the PowPak® will be erased
and will need to be re‑programmed.
Favorite
Set Low-End and High-End Trim
For best results, minimize the amount of sunlight entering the room before performing the following procedures.
Low-End Trim
Enter low-end trim adjustment mode:
Press and hold Lower button “ ” for 12 seconds.
Lights will flash high-low-high and LED will begin flashing.
Adjust the low-end trim:
Use Raise button “ ” and Lower button “ ” to adjust and set the lights to the desired low-end (1 to 45%).
Save the low-end trim:
Press and hold Toggle button “ ” for 6 seconds to save setting.
Notes
LED will begin flashing and then turn solid to indicate new level has been saved.
Depending on the fixture
High-End Trim
manufacturer or load, low-end
and high-end trim may need to
Enter high-end trim adjustment mode:
be adjusted.
Press and hold Raise button “ ” for 12 seconds.
• Trim low-end to ensure a stable
light level because some loads
Lights will flash high-low-high and LED will flash.
will flicker or drop out if trimmed
too low.
Adjust the high-end trim:
•
Be sure that you can turn on the
Use Raise button “ ” and Lower button “ ” to adjust and set the lights to the desired high-end
lights to the low-end trim level
(55 to 100%).
without any abnormal operation.
•
The factory default high-end trim
Save the high-end trim:
will normally be sufficient for most
Press and hold Toggle button “ ” for 6 seconds to save setting.
applications. Trim as desired.
LED will begin flashing and then turn solid to indicate new level has been
Troubleshooting
Ballasts cannot be controlled locally from
PowPak® Dimming Module.
Lights do not dim or turn ON as expected.
Lights do not respond to Wireless Transmitter(s).
www.lutron.com
• Ensure that the breaker(s) to the PowPak® Dimming Module are energized.
• Ensure that the PowPak® Dimming Module switched hot lead is wired to the ballast(s).
• Ensure that the PowPak® Dimming Module 0 –10 V control lines are wired to the ballast(s).
Reset to factory defaults.
• Ensure that 0 –10 V control lines are wired properly.
• Ensure that fixture does not require an inverted signal (10 – 0 V control).
• Ensure that the wires are connected between the Project 37 Sensor and Project 37 Control Module
• Ensure that the breaker(s) to the PowPak® Dimming Module and ballasts are energized.
• Ensure that Wireless Transmitters are associated to the PowPak® Dimming Module.
Reset to factory defaults.
Lights are unstable at low‑end or flash/flicker at
turn-on or turn-off.
• Adjust low-end trim.
Wireless Transmitter(s) cannot be associated to
PowPak® Dimming Module.
• The maximum number of Wireless Transmitters have been associated to the PowPak® Dimming Module. To remove a previously set up Wireless
Transmitter, tap a Wireless Transmitter button three times; on the third tap hold for three seconds and then tap three more times.
FCC Information (FC-0, FC-1 and FC-2 only)
This device complies with part 15 of the FCC Rules and Industry
Canada license-exempt RSS standard(s). Operation is subject
to the following two conditions: (1) This device may not cause
interference, and (2) this device must accept any interference,
including interference that may cause undesired operation.
Modifications not expressly approved by Lutron Electronics Co.,
Inc. could void the user’s authority to operate this equipment.
NOTE: This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the
following measures:
• Re-orient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
Limited Warranty
Lutron EA Ltd. (“Lutron EA”) warrants each unit to be free from
defects in material and workmanship and to perform under
normal use and service. To the extent permitted by law, Lutron
EA and Lutron Electronics Co. Inc. (“Lutron”) make no warranties
or representations as to the units except as set forth herein. This
warranty shall run for a period of two years from the date of purchase
and Lutron’s obligations under this warranty are limited to remedying
any defect, replacing any defective part or replacement (at Lutron
EA’s sole option) and shall be effective only if the defective unit
is shipped to Lutron EA postage prepaid within 24 months after
purchase of the unit. Repair or replacement of the unit does not affect
the expiry date of the warranty. This warranty does not cover damage
or deficiencies due to abuse, misuse, inadequate wiring or insulation
or use or installation other than in accordance with instructions
accompanying the unit.
To the extent permitted by law, neither Lutron EA nor Lutron shall be
liable for any other loss or damage including consequential or special
loss or damages, loss of profits, loss of income, or loss of contracts
arising out of or relating to the supply of the unit or the use of the unit
and the purchaser assumes and will hold harmless Lutron EA and
Lutron in respect of all such loss or damage. Nothing in this warranty
shall have the effect of limiting or excluding Lutron EA’s or Lutron’s
liability for fraud or for death or personal injury resulting from its own
negligence, or any other liability, if and to the extent that the same
may not be limited or excluded as a matter of law.
This warranty does not affect the statutory rights of consumer
purchasers of this product.
Although every attempt is made to ensure that catalogue information
is accurate and up-to-date, please check with Lutron EA before
specifying or purchasing this equipment to confirm availability, exact
specifications, and suitability for your application.
For information on other products, please see the Warranty
enclosed with the product.
Lutron, Pico, PowPak, Energi TriPak, Clear Connect, EcoSystem,
and ) are registered trademarks and Radio Powr Savr is a
trademark of Lutron Electronics Co., Inc.
©2014 Lutron Electronics Co., Inc.
Lutron Electronics Co., Inc., 7200 Suter Road
Coopersburg, PA 18036-1299 U.S.A.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Create Date                     : 2014:07:30 08:41:10-04:00
Creator                         : Adobe InDesign CS6 (Windows)
Modify Date                     : 2014:07:31 09:59:40-04:00
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Metadata Date                   : 2014:07:31 09:59:40-04:00
Creator Tool                    : Adobe InDesign CS6 (Windows)
Instance ID                     : uuid:37165778-436f-47e4-a3dd-6f0593091c40
Original Document ID            : xmp.did:B9A671108F48E211AD8DDE0A1DBE8AD0
Document ID                     : xmp.id:462F5EADE617E411829FE7101954B087
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:452F5EADE617E411829FE7101954B087
Derived From Document ID        : xmp.did:452F5EADE617E411829FE7101954B087
Derived From Original Document ID: xmp.did:B9A671108F48E211AD8DDE0A1DBE8AD0
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Windows)
History Changed                 : /
History When                    : 2014:07:30 08:41:10-04:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 2
EXIF Metadata provided by EXIF.tools
FCC ID Filing: JPZ0108

Navigation menu