Lutron Electronics 0108 Controller User Manual
Lutron Electronics Company Inc Controller
User Manual
Required Components Project 37 | Installation 041467 Rev. A 07/2014 Part of the Energi TriPak® Family FC-1 (Project 37 Control Module) 120 – 277 V~ 50 / 60 Hz 1 A FC-0 (Project 37 Sensor) 12 V- 25 mA One Project 37 Control Module Load Status LED At least one Sensor or Pico® Wireless Control Raise Project 37 Control Module with 0 –10 V Note: Project 37 Control Module can be used without a Sensor Important Notes: Please read before installing. For installation by a qualified electrician in accordance with all local and national electrical codes. Note: Use copper conductors only. Check to see that the device type and rating is suitable for the application. DO NOT install if product has any visible damage. If moisture or condensation is evident, allow the product to dry completely before installation. Operate between 0 °C and 40 °C, ambient. 0% to 90% humidity, non-condensing. For indoor use only. Project 37 Control Module Install control module directly to fixture or in junction box nearest the fixture. Install sensor in ceiling near fixture so as to optimize coverage in the desired area. Project 37 Control Module Sensor 30 ft (9 m) English Radio Powr SavrTM Occupancy/Vacancy Sensor Project 37 Occupancy/Vacancy and Daylight Sensor (1 maximum) 30 ft (9 m) max Pico® Wireless Control 6 mA maximum for the control lines. Switches up to 1 A total. May be pre-installed in light fixture. (10 maximum) (10 maximum) Hot (Bla Start Here Install Project 37 Control Module and Sensor Suggested Installation Location: Close to the Fixture/Troffer. Hot (Black) Green/Yellow Neutral (White) Neutral WARNING! Shock Hazard. May result in serious injury or death. Turn off power at circuit breaker before installing the unit. The Project 37 Control Module can be installed in a fixture/troffer, junction box or marshalling box using the conduit nut (provided) or with mounting screws (not provided). Please consult local and national electric codes for proper installation. If installing unit inside a junction box, please see Application Note #423 at www.lutron.com/TechnicalDocumentLibrary/048423.pdf B Ideally mount the sensor to the ceiling tile close to the fixture using the wire form or using the command strips (included). The 2 communication wires from the sensor attaches to the control module poke in connectors. C Once installed, energize the Project 37 Control Module. Fixture/Troffer or Junction Box Fixture Earth NEU Switched Hot (Red) HOT Violet Gray – Class 2 • • • Daylight Lens MAINS • • Consult third-party 0 – 10 V fixtures installation guide for fixture-specific wiring. PIR Lens Laser Detection Lower Control: 0–10 V- 6 mA At least one 0 – 10 V Fluorescent Ballast or LED Driver Toggle UL 2043 Plenum Rated • • Technical Assistance | 1.800.523.9466 USA, Canada, and the Caribbean | +44.(0)20.7702.0657 Europe | +1.610.282.3800 Others | www.lutron.com For each fixture, ensure that you have: The Project 37 sensor mounts to the ceiling surface with a supplied wireform clip. Two wires connect to the control module and can either be routed through a hole in the ceiling or across the ceiling surface. DO NOT install on ceilings higher than 12 ft (3.7 m). The sensor should be installed in a location where it has a good view of the space that it is meant to cover. Slide closed end of wire form under the two retention arms on the back of the sensor While continuing to push against the retention arms, rock the other side of the wireform down against the sensor and slide them into place under the loop retention features 1/2 in (21 mm) Knockout Opening Conduit Nut From back of sensor Pico® Wireless Control Neutral Install the Sensor Spring arms Note: For solid ceilings or others where the wireform cannot be utilized, use the supplied Command strips to adhere sensor to desired location on ceiling or fixture. Push wireform through tile and bend on the backside of the tile to complete the mounting. 40 ft (12 m) All Wireless Transmitters must be installed within 30 ft (9 m) of the Project 37 Control Module. Associate Wireless Transmitters to Project 37 Control Module Sensor Detection Range Before beginning this step, make sure that there are no other Project 37 Control Modules being set up in the building which are currently in this association mode.. It is possible that wireless transmitters from other systems can be incorrectly associated to this module. Ceiling A Initiate association mode on the Project 37 Control Module by shining a green laser pointer at the laser detection hole on the sensor until the load attached to the Project 37 Control Module starts flashing every 2 seconds. Alternatively, press and hold the toggle button for 6 seconds on the Project 37 Control Module to initiate association mode. B Hold the indicated button on each transmitter for 6 seconds. The fixture will flash to show that wireless transmitters have been associated. To associate another transmitter, repeat steps 4A and 4B. Default Functionality 9 ft (2.75 m) Floor 15 ft (4.6 m) 15 ft (4.6 m) Wireless Controls 9 ft (2.7 m) 3 ft (0.9 m) 3 ft (0.9 m) 9 ft (2.7 m) 15 ft (4.6 m) 400 ft2 (37 m2) maximum coverage area of one sensor whenmounted on an 9 ft (2.75 m) ceiling Laser Detection (smallest) On All lights 100% Favorite All lights 50% Off All lights off Link Test OR 9 ft (2.7 m) 3 ft (0.9 m) 3 ft (0.9 m) Green laser specifications: • Wave output: constant • Wavelength: 532 nm • Output power: 5 mW maximum Lutron Electronics Co., Inc., 7200 Suter Road Coopersburg, PA 18036-1299 U.S.A. 9 ft (2.7 m) 15 ft (4.6 m) 15 ft (4.6 m) 9 ft (2.7 m) 3 ft (0.9 m) 3 ft (0.9 m) 9 ft (2.7 m) 15 ft (4.6 m) Project 37 Load Control Module | Programming Part of the Energi TriPakR Family 041467 Rev. A 07/2014 ALL PROGRAMMING IS OPTIONAL Set a Favorite Light Level Technical Assistance | 1.800.523.9466 USA, Canada, and the Caribbean | +44.(0)20.7702.0657 Europe | +1.610.282.3800 Others | www.lutron.com For Pico® Wireless Controls with a Favorite Button. A Adjust lights to desired level: Raise Lower Use Raise button “ ” or Lower button “ ” on Pico® wireless control. Programming is not required for default functionality • Set a favorite light level • Set high-end and low-end trim for all fixtures B Save favorite level: Press and hold Favorite button for 6 seconds. The load flashes 3 times to confirm that the set level is saved. Reset Factory Defaults Note: In some instances, it may be necessary to reset the PowPak® Dimming Module and connected devices back to factory default settings. Before beginning, make sure that all devices are connected and powered. A Triple-tap any button on the PowPak® Dimming Module and hold until the LED begins to flash slowly; release button. B Within 3 seconds of the start of flashing, triple‑tap the same button again and the LEDs will flash rapidly indicating that the unit has been reset to factory defaults. Note: Any associations or programming previously set up with the PowPak® will be erased and will need to be re‑programmed. Favorite Set Low-End and High-End Trim For best results, minimize the amount of sunlight entering the room before performing the following procedures. Low-End Trim Enter low-end trim adjustment mode: Press and hold Lower button “ ” for 12 seconds. Lights will flash high-low-high and LED will begin flashing. Adjust the low-end trim: Use Raise button “ ” and Lower button “ ” to adjust and set the lights to the desired low-end (1 to 45%). Save the low-end trim: Press and hold Toggle button “ ” for 6 seconds to save setting. Notes LED will begin flashing and then turn solid to indicate new level has been saved. Depending on the fixture High-End Trim manufacturer or load, low-end and high-end trim may need to Enter high-end trim adjustment mode: be adjusted. Press and hold Raise button “ ” for 12 seconds. • Trim low-end to ensure a stable light level because some loads Lights will flash high-low-high and LED will flash. will flicker or drop out if trimmed too low. Adjust the high-end trim: • Be sure that you can turn on the Use Raise button “ ” and Lower button “ ” to adjust and set the lights to the desired high-end lights to the low-end trim level (55 to 100%). without any abnormal operation. • The factory default high-end trim Save the high-end trim: will normally be sufficient for most Press and hold Toggle button “ ” for 6 seconds to save setting. applications. Trim as desired. LED will begin flashing and then turn solid to indicate new level has been Troubleshooting Ballasts cannot be controlled locally from PowPak® Dimming Module. Lights do not dim or turn ON as expected. Lights do not respond to Wireless Transmitter(s). www.lutron.com • Ensure that the breaker(s) to the PowPak® Dimming Module are energized. • Ensure that the PowPak® Dimming Module switched hot lead is wired to the ballast(s). • Ensure that the PowPak® Dimming Module 0 –10 V control lines are wired to the ballast(s). Reset to factory defaults. • Ensure that 0 –10 V control lines are wired properly. • Ensure that fixture does not require an inverted signal (10 – 0 V control). • Ensure that the wires are connected between the Project 37 Sensor and Project 37 Control Module • Ensure that the breaker(s) to the PowPak® Dimming Module and ballasts are energized. • Ensure that Wireless Transmitters are associated to the PowPak® Dimming Module. Reset to factory defaults. Lights are unstable at low‑end or flash/flicker at turn-on or turn-off. • Adjust low-end trim. Wireless Transmitter(s) cannot be associated to PowPak® Dimming Module. • The maximum number of Wireless Transmitters have been associated to the PowPak® Dimming Module. To remove a previously set up Wireless Transmitter, tap a Wireless Transmitter button three times; on the third tap hold for three seconds and then tap three more times. FCC Information (FC-0, FC-1 and FC-2 only) This device complies with part 15 of the FCC Rules and Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation. Modifications not expressly approved by Lutron Electronics Co., Inc. could void the user’s authority to operate this equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Re-orient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Limited Warranty Lutron EA Ltd. (“Lutron EA”) warrants each unit to be free from defects in material and workmanship and to perform under normal use and service. To the extent permitted by law, Lutron EA and Lutron Electronics Co. Inc. (“Lutron”) make no warranties or representations as to the units except as set forth herein. This warranty shall run for a period of two years from the date of purchase and Lutron’s obligations under this warranty are limited to remedying any defect, replacing any defective part or replacement (at Lutron EA’s sole option) and shall be effective only if the defective unit is shipped to Lutron EA postage prepaid within 24 months after purchase of the unit. Repair or replacement of the unit does not affect the expiry date of the warranty. This warranty does not cover damage or deficiencies due to abuse, misuse, inadequate wiring or insulation or use or installation other than in accordance with instructions accompanying the unit. To the extent permitted by law, neither Lutron EA nor Lutron shall be liable for any other loss or damage including consequential or special loss or damages, loss of profits, loss of income, or loss of contracts arising out of or relating to the supply of the unit or the use of the unit and the purchaser assumes and will hold harmless Lutron EA and Lutron in respect of all such loss or damage. Nothing in this warranty shall have the effect of limiting or excluding Lutron EA’s or Lutron’s liability for fraud or for death or personal injury resulting from its own negligence, or any other liability, if and to the extent that the same may not be limited or excluded as a matter of law. This warranty does not affect the statutory rights of consumer purchasers of this product. Although every attempt is made to ensure that catalogue information is accurate and up-to-date, please check with Lutron EA before specifying or purchasing this equipment to confirm availability, exact specifications, and suitability for your application. For information on other products, please see the Warranty enclosed with the product. Lutron, Pico, PowPak, Energi TriPak, Clear Connect, EcoSystem, and ) are registered trademarks and Radio Powr Savr is a trademark of Lutron Electronics Co., Inc. ©2014 Lutron Electronics Co., Inc. Lutron Electronics Co., Inc., 7200 Suter Road Coopersburg, PA 18036-1299 U.S.A.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Create Date : 2014:07:30 08:41:10-04:00 Creator : Adobe InDesign CS6 (Windows) Modify Date : 2014:07:31 09:59:40-04:00 Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Metadata Date : 2014:07:31 09:59:40-04:00 Creator Tool : Adobe InDesign CS6 (Windows) Instance ID : uuid:37165778-436f-47e4-a3dd-6f0593091c40 Original Document ID : xmp.did:B9A671108F48E211AD8DDE0A1DBE8AD0 Document ID : xmp.id:462F5EADE617E411829FE7101954B087 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:452F5EADE617E411829FE7101954B087 Derived From Document ID : xmp.did:452F5EADE617E411829FE7101954B087 Derived From Original Document ID: xmp.did:B9A671108F48E211AD8DDE0A1DBE8AD0 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Windows) History Changed : / History When : 2014:07:30 08:41:10-04:00 Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 2EXIF Metadata provided by EXIF.tools