Lutron Electronics 0120 RF In-Wall Occupancy Dimmer User Manual Vive Integral Fixture Controls INSTALL 041600
Lutron Electronics Company Inc RF In-Wall Occupancy Dimmer Vive Integral Fixture Controls INSTALL 041600
032515a_FCC_IC manual
Vive Sensor Dimmer / Switch Start Here Wiring For more information and additional wiring instructions, visit: www.lutron.com/TechnicalDocumentLibrary/048687.pdf and/or www.lutron.com/TechnicalDocumentLibrary/3691097.pdf Part of the Vive System 032515 Rev. A 06/2018 Please read before installing 0–10 V- RF Sensor Dimmer MRF2S-8SD010 MRF2S-8SDV010 English MRF2S-8SS MRF2S-8SSV 1. Turn off power Line / Hot Black Black 120–277 V~ 50 / 60 Hz 3. Open the app and follow the instructions. Mode Occ Lrn Fixd Vac Gray (–) Vive White Violet (+) Black Gray (–) Gray (–) White Violet (+) Violet (+) Black Alt 30 m 15 Canada: 120–277 V~ 50 / 60 Hz Lighting Electronic fluorescent ballast or LED driver 120 – 277 V~ 50 / 60 Hz 8 A Canada: 120 V~ 50 / 60 Hz 8 A PIR Hi Med Low Min Green Note: For further information on set up, programming, and troubleshooting with a Vive system, please refer to the installation instructions included with the Vive hub or visit www.lutron.com/vive Programming without a Vive Hub or in optional multi-location applications (associating wireless devices to sensor dimmer / switch) White Ground Compatible Devices Works with all ballasts and drivers that provide a current source compliant to ANSI C137.1-201x 0–10 V. 1. Press and hold T for until the lights flash (about 7 seconds). Neutral b. Sensor Switch - Single Pole Wiring Line / Hot 0–10 V- Load Rating • One sensor dimmer / switch can sink up to 50 mA of current. • Controls up to 25 drivers or ballasts. • ANSI C137.1-201x 0–10 V requires the driver / ballast to limit the current draw to 2.0 mA maximum. Black 120–277 V~ 50 / 60 Hz 120–277 V~ 50 / 60 Hz Motion Coverage • Major: 30 ft × 30 ft (9 m × 9 m) [900 ft2 (81 m2)] • Minor: 20 ft × 20 ft (6 m × 6 m) [400 ft2 (36 m2)] Black Alt 30 m 15 Mode Occ Lrn Fixd Vac White White 2. Press and hold the wireless device button shown below until the lights flash (about 6 seconds). Pico wireless control (up to 10) Black Canada: Radio Powr Savr daylight sensor (1 maximum) Radio Powr Savr occupancy / vacancy sensor (up to 10) Alt 30 m 15 Mode Occ Lrn Fixd Vac Link Test PIR Hi Med Low Min PIR Hi Med Low Min Black Green White Ground Neutral Note: Program all desired settings before installing the wallplate. 3. Turn on power WARNING: Shock Hazard. Could result in minor or moderate personal injury. Ground connection required before connecting power Note: To associate multiple wireless devices, repeat steps 1 and 2 above for each wireless device. Un-associating a wireless device from a sensor dimmer/switch 1. Rapidly tap the wireless device button three times and hold on the fourth until the lights begins to flash rapidly; release the button. Within 1 second of releasing the button, rapidly tap it three times again. 2. To test that the wireless device has been successfully un-associated, press “Test” or d and verify that the wireless device no longer controls the load. 4. Wait 2 minutes •T he sensor dimmer / switch will manually control the load after the first 10 seconds. • Once power has been restored, the sensor dimmer / switch will automatically control the load after the first 2 minutes. 5. Set desired settings (optional) • See other side of sheet for details on how to select custom settings. • FCC / IC - Supplier Declaration of Conformity • • • This device complies with part 15 of the FCC Rules and Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference and (2) This device must accept any interference, including interference that may cause undesired operation. Modification not expressly approved by Lutron Electronics Co., Inc. could void the user’s authority to operate this equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Re-orient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Ce dispositif est conforme à la section 15 des règlements du FCC et des standards CNR exempt de licence d’Industrie Canada. L'opération est sous réserve des deux conditions suivantes : (1) Cet appareil ne peut causer d'interférence nuisible, et (2) Cet appareil doit tolérer toute interférence, même celle pouvant affecter son fonctionnement. Tout changement ou modification sans l'autorisation expresse de Lutron Electronics Co., Inc. pourrait annuler le droit d'utiliser cet équipement. REMARQUE : Cet équipement a été testé et jugé conforme aux limites applicables aux dispositifs numériques Classe B, conformément à la section 15 des régles de la FCC. Ces limites sont conçues pour procurer une protection raisonnable contre les perturbations nuisibles en application résidentielle. Cet équipement génère, utilise et peut radier l'énergie de fréquences radiophoniques. S'il n'est pas installé et utilisé selon les directives, peut causer des interférences radiophoniques nuisibles. Cependant, il n’y a aucune garantie qu’aucune interférence ne se produira dans une installation précise. Si votre équipement produit de l'interférence à la réception radiophonique ou télévisuelle, ce qui peut être détecté en coupant et refermant l'alimentation au système d’éclairage. Dans le cas d’interférence, l'utilisateur sera contraint d’essayer de corriger la situation par un ou plusieurs des moyens suivants : Lutron Electronics Co., Inc. 7200 Suter Road Coopersburg, PA 18036-1299 USA 2. Download the Lutron Vive app. a. Sensor Dimmer - Single Pole Wiring For set-up, programming, and troubleshooting with a Vive system, please refer to the installation instructions included with the Vive hub or at www.lutron.com Important Notes: • Neutral is required for product to function. If a neutral wire is not present, consult a licensed electrician. • When power is applied, the sensor dimmer / switch can be manually turned on / off after the first 10 seconds and the sensor will automatically control the load after 2 minutes. • The sensor requires an unobstructed view of the room and line‑of‑sight to detect motion. • Hot objects or moving air currents can affect the performance of the sensor and may cause it to turn on unexpectedly or not function as desired. • CAUTION: To reduce the risk of overheating and possible damage to other equipment, do NOT use to control receptacles. • Class 2 / Class 1 wiring: Install in accordance with all national and local electrical codes. • For indoor use only. Operate between 32 °F – 104 °F (0 °C – 40 °C), ambient. 0% to 90% humidity, non-condensing. • Clean only with soft, damp cloth, no chemical cleaners. 1. U se an iOSR or AndroidT compatible device. 2. Connect Wires Occupancy / Vacancy Vacancy Only Wireless Communication • Range of wireless communication is 60 ft (18 m) line-of-sight or 30 ft (9 m) through walls. • Wireless communication is affected by the installation or physical setup of the room. • Keep all wireless devices visible within the space. Do not place behind large furniture or appliances. • Do NOT mount in a metal partition wall or metal power pole. Programming with a Vive Hub WARNING: Shock Hazard. May result in serious injury or death. Turn OFF power at circuit breaker or fuse before installing or servicing the unit. Occupancy / Vacancy Vacancy Only RF Sensor Switch Customer Assistance | 1.844.LUTRON1 U.S.A. / Canada | +1.888.235.2910 Mexico | +1.610.282.3800 Others | www.lutron.com/support • Réorienter ou re-localiser l'antenne de réception • Augmenter la distance séparant l'équipement et le récepteur • Brancher l’équipement sur un circuit différent que celui sur lequel le récepteur est branché • Demander l'aide du distributeur ou d'un technicien expérimenté en radio et télévision Link Test Link Test Default settings in bold Vive Sensor Dimmer / Switch 1. Press and hold the desired programming button ( Programming is not required for default functionality Timeout 4 Default Settings 100% 55% Mode Occ Lrn Fixd Vac To display the current settings, tap the Timeout ( ), Sensor Mode ( M ), or PIR Sensitivity ( P ) button. The indicator LED ( IL ) that corresponds to the current setting will illuminate. Mode Tapswitch (on / off) Maestro LEDs Mode Occ Lrn Fixd Vac Raise Indicator LEDs 2 Alt Alt See Test Mode section. Occ Lrn Fixd Vac 30 m 15 ML IL 30 m 15 Hi Med Low Min Alt Lower 3 PIR PIR sensitivity 4 Sensor dimmer shown ensor Mode is locked as “Vacancy” in vacancy only models (MRF2S-8SDV010 and MRF2S-8SSV). Available in standalone. Not available when used in a Vive system. Only available with the sensor dimmer. Not available with sensor switch. Available in standalone. When the device is used in a Vive system, these adjustments are only available via the Vive software. Learning ALD (Ambient Light Detection): Lights remain off if enough natural light is present. If the lights turn on and the user does not want that much light, they can tap T within 5 seconds of entering the space. Similarly, if the lights do not turn on when entering a space and the user wants more light, they can tap T within 5 seconds of entering the space. Over time, the sensor will learn the preferred light level. Fixed ALD: Lights turn on only when there is less than a set (locked) amount of natural light available. The level can be adjusted in “Fixed ALD Level” settings. This setting will override the sensor mode of the Radio Powr Savr occupancy / vacancy sensor. Lutron Electronics Co., Inc. 7200 Suter Road Coopersburg, PA 18036-1299 USA Test Mode flashes (about 3 seconds). Test mode has a short timeout (< 15 seconds) that will test the coverage of the sensor with the current settings. (determines when lights turn on) Occupancy (Auto-ON / Auto-OFF)4 Occupancy with Learning ALD 2, 5 Occupancy with Fixed ALD 2, 6 Vacancy (Manual-ON / Auto-OFF)4 1. Wait at least 2 minutes after power is turned on. P PIR Sensitivity 4 2. Press and hold Reset Factory Defaults Note: It may be necessary to reset the device to factory default settings. Before beginning, ensure the device is connected and powered. 30 m 15 Mode Occ Lrn Fixd Vac 1. Press and hold T and R until a ML flashes (about 6 seconds). 2. Press and hold R until the top ML is lit and the lights stop brightening. 3. Tap L until the desired level is achieved. Press and hold T until the ML stops flashing (about 6 seconds). Note: Any associations or programming previously set up with the sensor dimmer / switch will be erased and will need to be re‑programmed after resetting to factory defaults. 1. Rapidly tap Alt 1% 1. Press and hold T and L until a ML flashes (about 6 seconds). 2. Press and hold L until the bottom ML is lit and the lights stop dimming. 3. Tap R until the lights are on and stable (no flickering) and the desired level is achieved. Press and hold stops flashing (about 6 seconds). until the PIR lens flashes (about 3 seconds). The sensor LED behind the lens will turn on while occupied and turn off while vacant. PIR Hi Med Low Min 3. The device will exit test mode after 5 minutes of inactivity or when any button is pressed. High Medium Low Minimum Low-End Trim 3, 4 three times and hold on the fourth until the lights begins to flash rapidly; release 2. Within 1 second of releasing T , rapidly tap device has been reset to factory defaults. until the three times again and the lights will flash slowly indicating that the ML PIR Occupancy Level 3, 4 Hi Med Low Min The level which the sensor dimmer turns on when motion is detected. This level is adjustable from 1% to 100% within the range of the low-end and high-end trims. 100% 1. Press and hold M and R until a ML flashes (about 6 seconds). L until desired level is achieved. Alt 2. Tap R or 3. Press and hold M until the ML stops flashing (about 6 seconds). Troubleshooting Symptom www.lutron.com/support Possible Causes and Solutions 1% PIR Vacancy Level 3, 4 Hi Med Low Min The level which the sensor dimmer dims or turns off when motion has not been detected for the timeout period. This level is adjustable from 1% to 100% within the range of the low-end and high-end trims. 100% 1. Press and hold M and L until a ML flashes (about 6 seconds). L until desired level is achieved. Alt 2. Tap R or 3. Press and hold M until the ML stops flashing (about 6 seconds). Lights can not be manually turned ON or OFF with the newly installed sensor dimmer / switch. • Verify proper wiring. Neutral must be connected for product to function properly. • Wait 10 seconds and try to turn ON or OFF again. Wireless device will not associate to a sensor dimmer / switch. • Wireless device is out of range. • Wireless performance is being affected by the physical setup of the space. See Wireless Communication section for more information. Not all of the sensor modes are available when programming. • Sensor modes are limited for vacancy only models (MRF2S-8SDV010 and MRF2S-8SSV). • Device may be part of a Vive system. Lights do not automatically turn ON when space is occupied. • Sensor Mode is set to Vacancy (Manual-ON / Auto-OFF). • The sensor dimmer / switch may be a vacancy only model (MRF2S-8SDV010 and MRF2S-8SSV). • The room may be too bright for the current light level setting for Fixed ALD Level. 0% PIR Fixed ALD Level 2 (MRF2S-8SD010 and MRF2S-8SS only) Hi Med Low Min The light level that determines when a sensor will turn lights on or keep lights off when detecting occupancy. This setting only affects sensors set to “Fixed ALD” mode. 1. Press and hold M and Alt until an IL flashes (about 3 seconds). 2. The “Fixed ALD” light level will now be displayed by the IL . Tap M to cycle to the desired setting. 3. Press and hold M until the IL turns solid (about 3 seconds). High (turn ON lights unless area has a lot of light) Medium Low Minimum (turn ON lights only when room is dark) PIR lens Alt 30 m 15 30 m 15 Sensor LED (behind lens) IL High-End Trim 3, 4 Check Current Settings2 Sensor mode 4, 7 ) until an For complete programming options and additional information, visit www.lutron.com/TechnicalDocumentLibrary/048687.pdf 45% Change Advanced Settings Timeout: 15 minutes Sensor Mode: Occupancy (Auto-On / Auto-Off)1 PIR Sensitivity: High Occupied Level: 100% Vacancy Level: 0% Fixed ALD Level: Low (when in Fixed ALD mode) Occ Lrn Fixd Vac , or M Sensor Mode 1 30 minutes 15 minutes 5 minutes 1 minute For set-up, programming, and troubleshooting with a Vive system, please refer to the installation instructions included with the Vive hub or at www.lutron.com Mode 3. Press and hold the same programming button until the IL turns solid (about 3 seconds). The setting has been saved. ALL PROGRAMMING IS OPTIONAL Timeout 2. Tap the same programming button to cycle to your desired setting. Part of the Vive System Customer Assistance | 1.844.LUTRON1 U.S.A. / Canada | +1.888.235.2910 Mexico | +1.610.282.3800 Others | www.lutron.com/support Change Basic Settings Walk-through Mode 2 Alt Allows the lights to turn off before the Timeout has expired if occupancy is detected only briefly. 30 m 1. Press and hold and Alt until an IL flashes (about 3 seconds). 15 (unused) (unused) 2. The walk-through setting will now be displayed by the IL . Tap Alt to cycle to the desired setting. Disabled 3. Press and hold Alt until the IL turns solid (about 3 seconds). Enabled Electronic Off 2 Mode PIR Alt Hi off. If enabled, the driver will still have power but the lights will be turned off. If disabled, the driver will Affects how the lights are turned Occ 30 Lrnm have power and the lights Med not will be turned off. 15 Low Fixd 5Vac (unused) 1. Press andMinhold and M until an IL flashes (about 3 seconds). (unused) 2. he electronic off setting will now be displayed by the IL . Tap M to cycle to the desired setting. Enabled 3. Press and hold M until the IL turns solid (about 3 seconds). Disabled PIR Mode Hi Occ Alt Med Lrn 30 Fixd 15 Vac Low Min Lutron, Pico, Maestro, and Vive are trademarks of Lutron Electronics Co., Inc. registered in the U.S. and other countries. Radio Powr Savr is a trademark of Lutron Electronics Co., Inc. App Store is a service mark of Apple, Inc. Android and Google Play are trademarks of Google LLC. iOS is a trademark or registered trademark of Cisco in the U.S. and other countries and is used under license. © 2018 Lutron Electronics Co., Inc. Mode Occ PIR Hi Med Driver / ballast cannot be dimmed up or down. Lens flashes when trying to dim the lights. • Verify proper connection of gray and purple wires. • Driver / ballast does not comply with ANSI C137.1-201x 0–10 V. See www.lutron.com/TechnicalDocumentLibrary/048687.pdf
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2018:06:18 13:49:28-04:00 Creator : Adobe InDesign CS6 (Windows) Modify Date : 2019:01:03 11:14:55-05:00 Has XFA : No Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.6-c016 91.163616, 2018/10/29-16:58:49 Format : application/pdf Title : Vive Integral Fixture Controls INSTALL (041600) Description : Vive Integral Fixture Controls INSTALL (041600) Subject : Vive Integral Fixture Controls INSTALL (041600), Vive, Lutron, 041600, 041-600, DFCSJ-OEM-OCC, DFCSJ-OEM-RF, daylight sensor Metadata Date : 2019:01:03 11:14:55-05:00 Creator Tool : Adobe InDesign CS6 (Windows) Instance ID : uuid:d13fc669-f40f-4231-92ae-076ada9db246 Original Document ID : xmp.did:B9A671108F48E211AD8DDE0A1DBE8AD0 Document ID : xmp.id:317775DF1F73E811A92DD15589C15C5A Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:307775DF1F73E811A92DD15589C15C5A Derived From Document ID : xmp.did:307775DF1F73E811A92DD15589C15C5A Derived From Original Document ID: xmp.did:B9A671108F48E211AD8DDE0A1DBE8AD0 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Windows) History Changed : / History When : 2018:06:18 13:49:28-04:00 Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 2EXIF Metadata provided by EXIF.tools