INSTALLATIONINSTRUCTIONS
COMMERCIAL DRYER- Gas or Electric
INSTRUCTIONSPOUR NSTALLATION D'UNE
SECHEUSECOMMERCIALE- A gaz ou (_lectrique
Table of Contents/Table
des mati_res
........................................
2
l
MDE17MN
MDG17MN
MDE17CS
MDG17CS
W10184576A
SP-W10184577A
www.maytagcommerciallaundry.com
TABLEOF CONTENTS
DRYER SAFETY ............................................................................
TABLEDES MATIERES
2
SECURITI_ DE LA SECHEUSE
..............................................
22
INSTALLATION REQUIREMENTS .............................................. 5
Tools and Parts ..........................................................................
5
Location Requirements ..............................................................
5
Electrical Requirements - Gas Dryer ........................................ 7
Electrical Requirements - Electric Dryer (U.S.A. Only) ............ 8
Electrical Requirements - Electric Dryer (Canada Only) .......... 9
Gas Supply Requirements
....................................................
10
Venting Requirements ............................................................
11
INSTALLATION INSTRUCTIONS - COIN SLIDE
AND COIN BOX ......................................................................
12
EXIGENCES D'INSTALLATION ................................................
25
Outillage et pi_ces .................................................................... 25
Exigences d'emplacement
...................................................... 26
Specifications electriques - s6cheuse _ gaz ........................... 27
Specifications electriques - Pour le Canada seutement ......... 28
Specifications de I'alimentation en gaz .................................. 29
Exigences concernant I'evacuation .......................................... 30
INSTALLATION D'UNE GLISS_I_RE
ET D'UNE CAISSE ._ MONNAIE .............................................. 32
INSTALLATION INSTRUCTIONS - GAS DRYER ..................
Make Gas Connection ..............................................................
Connect Vent ............................................................................
Complete Installation ..............................................................
INSTALLATION INSTRUCTIONSELECTRIC DRYER ........
Make Electrical Connection ......................................................
Connect Vent ............................................................................
Complete Installation ..............................................................
CHANGING TO A 30- OR 60-MINUTE TIMING CAM ..........
REVERSING THE DOOR SWING ..........................................
13
13
13
13
14
14
18
18
19
19
Raccordement h la canalisation de gaz .................................. 32
Raccordement du conduit d'evacuation ................................ 32
Achever I'instaltation ................................................................ 33
INSTRUCTIONS D'INSTALLATION - SECHEUSE
I_LECTRIQUE ............................................................................
33
Raccordement du conduit d'evacuation ................................ 33
Achever l'instatlation ................................................................ 34
INSTALLATION D'UNE CAME DE MINUTAGE DE 30 OU 60
MINUTES ......................................................................................
34
INVERSION DU SENS D'OUVERTURE DE LA PORTE ............ 35
MAINTENANCE
20
INSTRUCTIONS
21
GARANTIE ....................................................................................
WARRANTY
INSTRUCT{ONS
..........................................
..............................................................................
INSTRUCTIONS
D'INSTALLATION
- SI_CHEUSE A GAZ .... 32
D'ENTRETIEN ..................................................
DRYERSAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
35
36
WARNING
- Clothes
dryer installation
- ".isk ofFire"
must be performed
- Install the clothes dryer according
by a qualified
to the manufacturer's
installer.
instructions
and local codes.
- Do not install a clothes dryer with flexible plastic venting materials,
if flexible metal
(foil type) duct is installed, it must be of a specific type identified by the appliance
manufacturer
as suitable for use with clothes dryers. Flexible venting materials
are
known to collapse, be easily crushed, and trap lint. These conditions will obstruct
clothes dryer airflow and increase the risk of fire.
- To reduce the risk of severe
injury or death, follow
all installation
instructions.
- Save these instructions.
WARNING: For your safety, the information in this manual must be followed to minimize
the risk of fire or explosion, or to prevent property damage, personal injury, or death.
- Do not store or use gasoline
or any other appliance.
or other flammable
vapors and liquids in the vicinity of this
- WHAT TO DO iF YOU SMELL GAS:
®Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
= Clear the room, building, or area of all occupants.
= Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
= if you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed
the gas supplier.
WARNING:
Gas leaks cannot always be detected
Gas suppliers recommend
For more information,
by a qualified
installer, service agency, or
by smell.
that you use a gas detector approved
by UL or CSA.
contact your gas supplier.
If a gas leak is detected,
follow the "What to do if you smell gas" instructions.
IMPORTANT: The gas installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1/NFPA 54 or the Canadian Natural Gas and Propane Installation Code, CSA B149.1.
The dryer must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National
Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1.
3
In the State of Massachusetts,
the following installation instructions apply:
[] Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by
the State of Massachusetts.
[] If using a ball valve, it shall be a T-handle type.
[] A flexible gas connector, when used, must not exceed 3 feet.
IMPORTANT SAFETY INSTRUCTIONS
WARNING:
To reduce the risk of fire, electric shock, or injury to persons when using the dryer, follow basic precautions,
including the following:
[]
Read all instructions
[]
Do not place items exposed to cooking oils in your dryer.
Items contaminated with cooking oils may contribute to
a chemical reaction that could cause a load to catch fire.
[]
Do not dry articles that have been previously cleaned in,
washed in, soaked in, or spotted with gasoline, drycleaning solvents, or other flammable or explosive
substances as they give off vapors that could ignite or
explode.
Do not allow children to play on or in the dryer. Close
supervision of children is necessary when the dryer is
used near children.
[]
before using the dryer.
Do not repair or replace any part of the dryer or attempt
any servicing unless specifically recommended in this
Use and Care Guide or in published user-repair
instructions that you understand and have the skills to
carry out.
[]
Do not use fabric softeners or products to eliminate static
unless recommended by the manufacturer of the fabric
softener or product.
[]
Do not use heat to dry articles containing foam rubber or
similarly textured rubber-like materials.
Clean lint screen before or after each load.
[]
[]
Keep area around the exhaust opening and adjacent
surrounding areas free from the accumulation of lint, dust,
and dirt.
Do not reach into the dryer if the drum is moving.
[]
Do not install or store the dryer where it will be exposed
to the weather.
The interior of the dryer and exhaust vent should be
cleaned periodically by qualified service personnel.
[]
See installation instructions
[]
Before the dryer is removed from service or discarded,
remove the door to the drying compartment.
[]
[]
[]
[]
for grounding
requirements.
Do not tamper with controls.
SAVE THESE INSTRUCTIONS
[]
It is recommended that the owner post, in a prominent location, instructions for the customer's use in the event the customer smells
gas. This information should be obtained from your gas supplier.
[]
Post the following warning in a prominent location.
and liquids
the vicinity of this or any other appliance.
I Do not store or use gasoline or other flammable vapors FOR
YOUR in
SAFETY
I
INSTALLATIONREQUIREMENTS
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools
listed here.
Tools needed
m 8" (20 cm) or 10" (25 cm) Pipe wrench
m 8" (20 cm) or 10" (25 cm) adjustable wrench
m Flat-blade screwdriver
m Phillips screwdriver
m Adjustable wrench that opens to 1" (25 mm) or 1" (25 mm)
hex-head socket wrench
m Level
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer.
m 5_6"socket wrench
Do not install in a garage.
m Utility knife
Failure to do so can result in death, explosion, or fire.
m Vent clamps
m Pipe-joint compound resistant to LP gas
m Caulk gun and caulk (for installing new exhaust vent)
m Pliers
if installing a gas dryer:
iMPORTANT:
Check code requirements: Some codes limit or do not permit
installation of clothes dryers in garages, closets, or sleeping
quarters. Contact your local building inspector.
[]
Make sure that lower edges of the cabinet, plus the back and
bottom sides of the dryer, are free of obstructions to permit
adequate clearance of air openings for combustion air. See
"Recessed Area and Closet Installation Instructions" below
for minimum spacing requirements.
m Putty knife
Parts supplied
Remove parts bag from dryer drum. Check that all parts were
included.
m Wedge Cone
m Foot boot (4)
m Dryer foot (4)
m 5_6-18 x 21Z2
'' bolt
m 3 pin timing cam
m 6 pin timing cam
Observe all governing codes and ordinances.
[]
NOTE: The dryer must not be installed in an area where it will
be exposed to water and/or weather.
Recessed
Area
and Closet
Installation
instructions
This dryer may be installed in a recessed area or closet.
For recessed area and closet installations, minimum clearances
can be found on the warning label on the rear of the dryer.
The installation spacing is in inches and is the minimum
allowable. Additional spacing should be considered for ease
of installation, servicing, and compliance with local codes
and ordinances.
If closet door is installed, the minimum unobstructed air opening
in the top and bottom is required. Louvered doors with equivalent
air openings are acceptable.
The dryer must be exhausted outdoors.
No other fuel-burning appliance may be installed in the same
closet as the dryer.
5
Minimum Installation Clearances
Product Dimensions 27" (686 ram) dryer
_ mm_
_--_
max._
_
oto
15"
Closet
(381 mm)*
Inl
{'4
r_
.........r
I
_L_CT_,C
_
0"
door _
0" (0 mm)
"_L_-----27 '' (686 mm)
___
/
(35.6 cm)
(0 mm)
[
37"
BACK VIEW
O"(0mm) _
(940mm)
/
"_
'==='="_l [_L_'''_
1'' (25 mm)
63/4 ''
Recessed front view
Closet side view
Additional clearances for wall, door and floor moldings may be required or if
external exhaust elbow is used.
13"
(152 mm)
£
4" (102 mm)
_
43/4"
/dia.
i
/
(121 mm)
ZZ;; ......L
3" (76 mm)
48 in_
(310 cm2)*
Front
View
i-4_--
11/4" ____
(32mm)
291/4'' (743 mm)
O
closet
door
261/2'' (673 mm)
[ ....
I
I
I
I
3" (76 mm)
Non-coinoperated models:
*Opening is the minimum for a closet door.
Louvered doors with equivalent air openings are acceptable.
71/8'' (181 mm)
SIDE VIEW
Coin-operated
models:
35"
(889 mm)
101/4''
(260 mm)
77/8'' (200 mm)
LEFT OR
RIGHT SIDE
i
T
41/4''
(108 mm)
3/4"
(21 mm)
I
71/4" I/I
(184 mm)
!
_
[
(359 mm)
¢_'
BOTTOM
EXHAUST
Recommended
Ground
Method
The dryer, when installed, must be electrically grounded in
accordance with local codes or, in the absence of local codes,
with the National Electrical Code, ANSl/NFPA 70, latest edition,
or Canadian Electrical Code, CSA C22.1, and all local codes
and ordinances.
GROUNDING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground
prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
iMPORTANT: The dryer must be electrically grounded in
accordance with local codes and ordinances or, in the absence of
local codes, with the National Electrical Code, ANSl/NFPA 70,
latest edition, or Canadian Electrical Code, CSA C22.1.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path is adequate.
INSTRUCTIONS
[] For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipmentgrounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING:
improper connection of the equipmentgrounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with the
dryer: if it will not fit the outlet, have a proper outlet installed
by a qualified electrician.
SAVE THESE
INSTRUCTIONS
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park, Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
[]
A 120 volt, 60 Hz, AC only, 15- or 20-amp, fused electrical
circuit is required. A time-delay fuse or circuit breaker is also
recommended. It is recommended that a separate circuit
serving only this dryer be provided.
7
if using
it is your responsibility
[]
To contact a qualified electrical installer.
[]
To be sure that the electrical connection is adequate and in
conformance with the National Electrical Code, ANSl/NFPA
70-latest edition and all local codes and ordinances.
The National Electrical Code requires a 4-wire power supply
connection for homes built after 1996, dryer circuits involved
in remodeling after 1996, and all mobile home installations.
a power
supply
cord:
Use a UL listed power supply cord kit marked for use with
clothes dryers. The kit should contain:
[]
A UL listed 30-amp power supply cord, rated 120/240 volt
minimum. The cord should be type SRD or SRDT and be at
least 4 ft (1.22 m) long. The wires that connect to the dryer
must end in ring terminals or spade terminals with upturned
ends.
[]
A UL listed strain relief.
If your ouUet looks like this:
A copy of the above code standards can be obtained from:
National Fire Protection Association, One Batterymarch Park,
Quincy, MA 02269.
[]
[]
[]
To supply the required 3 or 4 wire, single phase, 120/240 volt,
60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt
electrical supply, if specified on the serial/rating plate) on a
separate 30-amp circuit, fused on both sides of the line. A
time-delay fuse or circuit breaker is recommended. Connect
to an individual branch circuit. Do not have a fuse in the
neutral or grounding circuit.
Do not use an extension cord.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
Electrical
Connection
4-wire receptacle(14-30R)
Then choose a 4-wire power supply cord with ring or spade
terminals and UL listed strain relief. The 4-wire power supply
cord, at least 4 ft (1.22 m) long, must have four 10-gauge copper
wires and match a 4-wire receptacle of NEMA Type 14-30R. The
ground wire (ground conductor) may be either green or bare. The
neutral conductor must be identified by a white cover.
If your ouUet looks like this:
To properly install your dryer, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.
[]
This dryer is manufactured ready to install with a 3-wire
electrical supply connection. The neutral ground conductor is
permanently connected to the neutral conductor (white wire)
within the dryer. If the dryer is installed with a 4-wire electrical
supply connection, the neutral ground conductor must be
removed from the external ground connector (green screw),
and secured under the neutral terminal (center or white wire)
of the terminal block. When the neutral ground conductor is
secured under the neutral terminal (center or white wire) of the
terminal block, the dryer cabinet is isolated from the neutral
conductor.
[]
If local codes do not permit the connection of a neutral
ground wire to the neutral wire, see "Optional 3-wire
connection" section.
[]
A 4-wire power supply connection must be used when the
appliance is installed in a location where grounding through
the neutral conductor is prohibited. Grounding through the
neutral is prohibited for (1) new branch-circuit installations, (2)
mobile homes, (3) recreational vehicles, and (4) areas where
local codes prohibit grounding through the neutral conductor.
3-wire receptacle
(10-30R)
Then choose a 3-wire power supply cord with ring or spade
terminals and UL listed strain relief. The 3-wire power supply
cord, at least 4 ft (1.22 m) long, must have three 10-gauge copper
wires and match a 3-wire receptacle of NEMA Type 10-30R.
If connecting
bydirectwire:
Power
supply
cablemustmatchpowersupply(4-wire
or3-wire)
andbe:
[] Flexible
armored
cableornonmetallic
sheathed
copper
cable
(withground
wire),protected
withflexible
metallic
conduit.
All
current-carrying
wiresmustbeinsulated.
[] 10-gauge
solidcopper
wire(donotusealuminum).
[] Atleast5ft (1.52m)long.
GROUNDING
INSTRUCTIONS
[] For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer uses a cord having an equipment-grounding
conductor and a grounding plug. The plug must be plugged
into an appropriate outlet that is properly installed and
grounded in accordance with all local codes and ordinances.
[] For a permanently connected dryer:
This dryer must be connected to a grounded metal,
permanent wiring system, or an equipment-grounding
conductor must be run with the circuit conductors and
connected to the equipment-grounding terminal or lead on
the dryer.
WARNING:
Improper connection of the equipmentgrounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug on the power
supply cord: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE THESE
[] Tosupplytherequired
4wire,single
phase,
120/240
volt,60
Hz.,AConlyelectrical
supplyona separate
30-amp
circuit,
fusedonbothsidesoftheline.Atime-delay
fuseorcircuit
breaker
isrecommended.
Connect
toanindividual
branch
circuit.
[] Thisdryerisequipped
withaCSAInternational
Certified
Power
Cordintended
tobeplugged
intoa standard
14-30R
waltreceptacle.
Thecordis5 ft (1.52m)inlength.
Besure
wattreceptacle
iswithinreach
ofdryer's
finallocation.
INSTRUCTIONS
4-wire receptacle(14-30R)
[]
Do not use an extension cord.
If you are using a replacement power supply cord, it is
recommended that you use Power Supply Cord Replacement
Part Number 9831317. For further information, please
reference the service numbers located in the "Assistance
or Service" section.
GROUNDING
INSTRUCTIONS
[] For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipmentgrounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING:
improper connection of the equipmentgrounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with the
dryer: if it will not fit the outlet, have a proper outlet installed
by a qualified electrician.
SAVE THESE
Electrical
INSTRUCTIONS
Shock Hazard
Plug into a grounded 4 prong outlet.
Failure to do so can result in death or electrical
shock.
It is your responsibility
[]
To contact a qualified electrical installer.
[]
To be sure that the electrical connection is adequate and in
conformance with the Canadian Electrical Code, C22.1-1atest
edition and all local codes. A copy of the above codes
standard may be obtained from: Canadian Standards
Association, 178 Rexdate Blvd., Toronto, ON M9W 1R3
CANADA.
9
Gas
_iiiiiiii_i!:_!!iil;
iiii_i:!ii?ili:i::iiiii?
¸ !i:!_%i?_!:ii:ii::'_!i!:_:_iiii_:_i_i_!!%:i:!!ii_
Supply
Recommended
Line
method
[]
Provide a gas supply line of 1/2"rigid (IPS) pipe to the dryer
location. Pipe joint compounds that resist the action of LP gas
must be used. Do not use TEFLON _'t tape. With LP gas,
piping or tubing size can be 1/2"minimum. Usually, LP gas
suppliers determine the size and materials used in the system.
Alternate method
Explosion Hazard
Use a new CSA International
[]
approved gas supply line.
Install a shut=off valve.
Securely tighten all gas connections.
if connected to LP, have a qualified person make sure
gas pressure does not exceed 13" (330 rnnrn)water
column.
The gas supply may also be connected using %" approved
copper or aluminum tubing. If the total length of the supply
line is more than 20 ft. (6.1 m), larger tubing will be required.
If using natural gas, do not use copper tubing. Pipe joint
compounds that resist the action of LP gas must be used.
Flexible metal appliance
connector:
[]
It is recommended that a new flexible stainless steel gas line,
design-certified by CSA International, be used for connecting
the dryer to the gas supply line. (The gas pipe which extends
through the lower rear of the dryer is provided with %" mate
pipe thread.)
[]
Do not kink or damage the flexible stainless steel gas line
when moving the dryer.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
IMPORTANT: Observe all governing codes and ordinances.
This installation must conform with all local codes and
ordinances. In the absence of local codes, installation must
conform with American National Standard, National Fuel Gas
Code ANSI Z223.1/NFPA 54 or CAN/CSA B149.
Rigid pipe connection:
The rigid pipe connection requires a combination of pipe fittings
to obtain an in-line connection to the dryer.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park, Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
The design of this dryer has been certified by CSA International
for use at altitudes up to 10,000 feet (3048 m) above sea level at
the B.T.U. rating indicated on the model/serial plate. Burner input
adjustments are not required when the dryer is operated up to
this elevation.
When installed above 10,000 feet (3048 m), a four percent (4%)
reduction of the burner B.T.U. rating shown on the model/serial
plate is required for each 1,000 foot (305 m) increase in elevation.
For assistance when converting to other gas types and/or
installing above 10,000 feet (3048 m) elevation, contact your
local service company.
[]
Must include a shutoff valve:
The supply line must be equipped with a manual shutoff
valve installed within 6 ft. (1.8 m) of dryer in accordance
with National Fuel Gas Code, ANSI Z223.1. In Canada,
an individual manual shutoff valve must be installed in
accordance with the B149 installation codes CAN/CGA
B149.1 and CAN/CGA B149.2. This valve should be located
in the same room as the dryer. It should be in a location that
allows ease of opening and closing. Do not block access to
shutoff valve. The valve is for turning on or shutting off gas
to the dryer.
B
_'_'_",_,_,_,
D
ii
Type of Gas
This dryer is equipped for use with natural gas. It is designcertified by CSA International for LP (propane and butane) gases
with appropriate conversion. No attempt shall be made to convert
the dryer from the gas specified on the serial/rating plate for use
with a different gas without consulting the serving gas supplier.
Conversion must be done by a qualified service technician.
Gas conversion kit part numbers are listed on the gas valve
burner base.
A.
B.
C.
D.
Gas supply line
Shutoff valve in "open" position
To dryer
NPT 1/8" min. plugged tapping
1-®TEFLON is a registered trademark
10
of E.I. Du Pont De Nemours and Company.
[]
Installed in a confined area:
If the dryer is installed in a confined area such as a bathroom
or closet, provision must be made for enough air for
combustion and ventilation. Check governing codes and
ordinances or refer to the "Recessed Area and Closet
Installation Instructions" in the "Location Requirements"
section.
Exhaust hood must be at least 12" (305 mm) from the ground
or any object that may be in the path of the exhaust (such as
flowers, rocks, or bushes).
If using an existing vent system, clean lint from the entire length
of the system and make sure exhaust hood is not plugged with
lint. Replace any plastic or metal foil vent with rigid metal or
flexible metal vent.
Plan installation to use the fewest number of elbows and turns.
Gas Supply
Pressure
Testing
A 1A" NPT minimum plugged tapping, accessible for gauge
testing, must be installed immediately upstream of the installed
shut-off valve to the dryer.
The dryer must be disconnected from the gas supply piping
system during any pressure testing of the system at test
pressures in excess of 1Z2"psig.
ExhaustAir Flow
A. Good
B. Better
Allow as much room as possible when using elbows or making
turns. Bend vent gradually to avoid kinking.
Vent outlet is located at the back of the dryer, at bottom center.
The vent can be routed up, down, left, right, or straight out the
back of the dryer.
Vent System
Fire Hazard
Length
Maximum length of vent system depends upon the type of
vent used, number of elbows, and type of exhaust hood.
The maximum length for rigid vent is shown in the chart.
Use a heavy metal vent,
Do not use a plastic vent.
Do not use a metal foil vent,
Failure to follow these instructions
or fire.
Maximum Vent Length
can result in death
WARNING;
To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
[]
[]
[]
The dryer vent must not be exhausted into any gas vent,
chimney, walt, ceiling, attic, crawtspace, or a concealed space
of a building.
4" (102 mm) Diameter Exhaust Hoods
Rigid Metal Vent
No. of 90 ° turns
Box Hood and Louvered Style
Angled Hood Style
0
130 ft. (39.6 m)
129 ft. (39.3 m)
1
125 ft. (38.1 m)
119 ft. (36.3 m)
Only rigid or flexible metal duct shall be used for exhausting.
2
115 ft. (35.1 m)
109 ft. (33.2 m)
Do not use an exhaust hood with a magnetic latch.
3
106 ft. (32.3 m)
100 ft. (30.5 m)
4
98 ft.
92 ft.
(29.9 m)
(28.0 m)
[]
Do not install flexible metal vent in enclosed walls, ceilings,
or floors.
[]
4" (102 mm) heavy metal vent and clamps must be used. Do
not use plastic or metal foil vent.
For vent systems not covered by the vent specification
see your parts distributor.
[]
Use clamps to seat all joints. The duct shall not be assembled
with screws or other fastening means that extend into the
duct and catch lint. Do not use duct tape.
[]
The total length of flexible metal vent shall not exceed 73/4ft
(2.4 m).
If dryer is installed in a confined area, such as a bedroom,
bathroom, or closet, provision must be made for enough air
for combustion and ventilation. (Check governing codes and
ordinances.) See "Recessed Area and Closet Installation
Instructions" in the "Location Requirements" section.
iMPORTANT:
Observe all governing codes and ordinances.
Rigid metal vent is recommended to prevent crushing and
kinking.
Flexible metal vent must be fully extended and supported when
the dryer is in its final position. Remove excess flexible metal vent
to avoid sagging and kinking that may result in reduced airflow
and poor performance.
chart,
A 4" (102 mm) outlet hood is preferred. However, a 21/,`' (64 mm)
outlet exhaust hood may be used. A 21/2`' (64 mm) outlet creates
greater back pressure than other hood types. For permanent
installation, a stationary vent system is required.
An exhaust hood should cap the vent to prevent rodents and
insects from entering the home or business.
11
Keep air openings free of dry cleaning fluid fumes. Fumes create
acids which, when drawn through the dryer heating units, can
damage dryers and loads being dried.
[]
[]
A main vent can be used for venting a group of dryers. The
main vent should be sized to remove 200 CFM of air per
dryer. Large-capacity lint screens of proper design may be
used in the main vent if checked and cleaned frequently. The
room where the dryers are located should have make-up air
equal to or greater than the CFM of all the dryers in the room.
Back-draft Damper Kit, Part No. 3391910, is available from
your dealer and should be installed in the vent of each dryer
to prevent exhausted air from returning into the dryers and
to keep the exhaust in balance within the main vent.
Unobstructed air openings are required.
A clean-out cover should be located on the main vent for periodic
cleaning of the vent system.
If an exhaust hood cannot be used:
The outside end of the main vent should have a sweep elbow
directed downward. If the main vent travels vertically through the
roof, rather than through the walt, install a 180° sweep elbow on
the end of the vent at least 2 ft. (610 mm) above the highest part
of the building. The opening in the walt or roof shall have a
diameter 1Z2"(13 mm) larger than the vent diameter. The vent
should be centered in the opening.
B
Each vent should enter the main vent at an angle pointing in the
direction of the airflow. Vents entering from the opposite side
should be staggered to reduce the exhausted air from interfering
with the other vents.
U
C
The maximum angle of each vent entering the main vent should
be no more than 30 °.
air flow
_
B
-_---
0w
E" 180f°sn:e;edbow
_. _o_al vent
A. Individualdryervent
B. Mainvent
...............
E
F
__
/-
_
J_::::::::_
G highestpoint
of building
Do not install screening or cap over the end of the vent.
INSTALLATION
INSTRUCTIONS
- COINSLIDEANDCOINBOX
The console houses the factory-installed
actuating arm and button.
accumulator
timer with
The factory-installed timer is set to provide 45 minutes (4 pins)
of drying time when activated by the coin slide. Timer cams for
30-minute (6 pins) and 60-minute (3 pins) drying times are
included in the parts bag.
The coin slide mechanism, control panel lock and key, and coin
box lock and key are not included and are available from usual
industry sources.
Excessive Weight Hazard
3=
Take two of the cardboard corners from the carton and place
them on the floor in back of the dryer. Firmly grasp the body
of the dryer and gently lay it on its back on the cardboard
corners.
4=
With one of the legs in hand, check the ridges for a diamond
marking. That's how far the leg is supposed to go into the
hole.
5=
Start to screw the leveling legs into the holes by hand. (Use a
small amount of liquid detergent to lubricate the screw
threads so it is easier to turn the legs.) Use a 1" (25 mm)
wrench or socket wrench to finish turning the legs until you
reach the diamond mark.
6=
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.
NOTE: Slide dryer onto cardboard or hardboard before moving to
avoid damaging floor covering.
1.
Using two or more people, move dryer to desired installation
location.
2. Take tape off front corners of dryer. Open dryer and remove
the literature and parts packages. Wipe the interior of the
drum thoroughly with a damp cloth.
12
Now stand the dryer up.
Remove the service
door of the meter case
by lifting it up at the
back. Install the moneyaccepting device. (Refer
to manufacturer's
instructions for proper
installation.)
For dryers using coin
slides, use the adapter kit supplied with the dryer.
7=
Replace the meter case service door. Put the coin vault with
lock and key in the meter case opening.
8.
Remove cardboard or hardboard from under dryer. Adjust the
legs of the dryer up or down until the dryer is level.
INSTALLATIONINSTRUCTIONS- GASDRYER
1=
With dryer in final position, place level on top of the dryer, first
side to side; then front to back. If the dryer is not level, adjust
the legs of the dryer up or down until the dryer is level.
Excessive Weight Hazard
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.
1.
Remove red cap from gas pipe.
2. Connect gas supply to dryer. Use pipe-joint compound
resistant to the action of LR gas for gas connections. If
flexible metal tubing is used, be certain there are no kinks.
Electrical Shock Hazard
If necessary for service, open the toe panel by removing the
21A'' hex-head screws from the bottom of the panel. Then lift
up on the panel while pulling the bottom of the panel away
from the dryer.
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
3. Open the shutoff valve in the gas supply line.
Do not use an adapter.
4. Test all connections by brushing on an approved noncorrosive
leak-detection solution. Bubbles will show a leak. Correct any
leak found.
Do not use an extension cord.
Failure to follow these instructions
fire, or electrical shock.
2.
1.
2.
Using a 4" (102 mm) clamp, connect vent to exhaust outlet
in dryer. If connecting to existing vent, make sure the vent is
clean. The dryer vent must fit over the dryer exhaust outlet
and inside the exhaust hood. Make sure the vent is secured
to exhaust hood with a 4" (102 mm) clamp.
can result in death,
Plug into a grounded 3 prong outlet.
3. Check dryer operation:
Insert coins. Operating time will accumulate per number of
coins. Push START/RESTART button. Using a full heat cycle
(not the air cycle), let the dryer run for at least five minutes.
Dryer will stop when time is used up.
Using two or more people, move dryer to desired installation
location. Do not crush or kink vent. Make sure dryer is level.
NOTE: Dryer door must be closed for dryer to operate. When
door is open, dryer stops, but timer continues to run. To
restart dryer, close door and push START/RESTART button.
3. Check to be sure there are no kinks in the flexible gas line.
4.
If the burner does not ignite and you can feel no heat inside
the dryer, shut off dryer for five minutes. Check that all supply
valve controls are in "ON" position and that the electrical cord
is plugged in. Repeat five-minute test.
5.
If drying time is too long, make sure lint screen is clean.
13
INSTALLATIONINSTRUCTIONS-ELECTRICDRYER
Power
Supply
Cord
Method
1.
Disconnect power.
2.
Remove hold-down screw and the terminal block cover.
= U.S. Only
A. External ground conductor screw
B. Tab
C. Terminal block cover
D. Hold-down screw
Fire Hazard
Use a new UL listed 30 amp power supply cord.
3=
Use a UL listed strain relief.
Disconnect power before making
electrical connections.
Assemble ,_A"(19 mm) UL-listed
strain relief) into the hole below
Tighten strain relief screws just
sections together. Install power
strain relief.
strain relief (UL marking on
the terminal block opening.
enough to hold the two clamp
supply cord through the
Connect neutral wire (white or center wire) to center
terminal (silver).
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals (gold),
Securely tighten
all electrical
connections.
A. Strain relief clamp sections
B. Dryer cabinet
C. Strain relief screws
Failure to do so can result in death, fire, or
electrical shock.
4=
This dryer is manufactured with the neutral ground wire
connected to the neutral (center) of the wiring harness at the
terminal block. If local codes do not permit this type of
connection, use "Four-wire connection" instructions.
Use a UL-listed power supply cord rated 240 volt min.,
30-amp and marked for use with a clothes dryer.
14
Complete installation following instructions for your type of
electrical connection:
* Four-wire (recommended
method)
Three-wire (if four-wire is not available)
Power Supply Cord,
Four-wire
electrical
connection:
B
C
A
6.
Remove the appliance neutral ground wire
from the external ground conductor screw.
Fasten under center, silver-colored
terminal block screw.
g
8. Connect the neutral wire (white or center)
of the power supply cord under the center
screw of the terminal block. Tighten
screw.
i'
A. Spadeterminalswithupturnedends
B. Neutral
C. s/4"(19mm) UL-Iistedstrainrelief
D. Neutral(white)
E. Ringterminals
F. Groundwire
G. Groundprong
Remove the center terminal block screw.
7. Connect the ground wire of the power
supply cord to the external ground
conductor screw. Tighten screw.
D
G
5.
/
E
9. Connect the other wires to outer terminal
block screws. Tighten screws.
10. Tighten strain relief screws.
11. Insert tab of the terminal block cover into
slot of the dryer rear panel. Secure cover
with hold-down screw.
A. External ground conductor screw
B. Appliance neutral ground wire
C. Center terminal block screw
D. Outer terminal block screws
E. Strain relief screw
F. Neutral (center wire)
G. Ground wire
Four-wire power supply cord must have four,
No. 10 copper wires and match a four-wire
receptacle of NEMA Type 14-30R. The
fourth wire (ground conductor) must be
identified by a green cover and the neutral
conductor by a white cover.
15
Use this method where local codes permit connecting
Power Supply Cord,
Three=wire electrical
connection:
neutral ground wire to neutral wire:
5.
Loosen
or remove the center terminal
block screw.
1_1_.__
F .....................
Connect the neutral wire (white or center)
of the power supply cord to the center,
silver-colored terminal screw of the
terminal block. Tighten screw.
7.
_m
A
E
O__1
..........
Connect the other wires to outer terminal
_
8. Tighten strain relief screws.
9. Insert
block tab
screws.
of the
Tighten
terminal
screws.
block cover into
slot of the dryer rear panel. Secure cover
with hold-down screw.
....................
B
A ................................ _Z_
.........
D ............
_
C
A. External ground conductor screw
B. Center terminal block screw
C. Outer terminal block screws
D. Strain relief screw
This bladeconnectedto
B
..............................
.....
.....this conductor.
E. Neutral (center wire)
F. Appliance neutral ground wire
E
D
C
A. Spade terminals with upturned ends
B. Ring terminals
C. Neutral (white or center)
D. s/4" (19 mm) UL-Iisted strain relief
E. Neutral
Three-wire power supply cord must
have three, No. 10 copper wires and
match a three-wire receptacle of NEMA
Type 10-30R.
Use this method where local codes do not permit
connecting neutral ground wire to neutral wire:
5.
Remove the center terminal block screw.
6.
Remove the appliance neutral ground wire
from the external ground conductor
screw. Connect the appliance neutral
ground wire and the neutral wire (white or
center) of the power supply cord under
the center, silver-colored terminal block
screw. Tighten screw.
A ..........!1
C
uw h
G
7. Connect the other wires to outer terminal
block screws. Tighten screws.
8. Tighten strain relief screws.
9. Insert tab of the terminal block cover into
slot of the dryer rear panel. Secure cover
with hold-down screw.
10. After reattaching the terminal cover,
connect a separate copper ground wire
from the external ground conductor screw
to an adequate ground.
If codes permit and a separate ground wire is
used, it is recommended that a qualified
electrician determine that the ground path is
adequate.
16
E
F ...................
A. Separate copper ground wire
B. External ground conductor screw
C. Appliance neutral ground wire
D. Center terminal block screw
E. Outer terminal block screws
F. Strain relief screw
G. Neutral (center wire)
Direct
Wire
Method
1.
2.
= U.S. Only
Disconnect power.
Remove hold-down screw and terminal block cover.
A. External ground conductor screw
B. Tab
C. Terminal block cover
D. Hold-down screw
Fire Hazard
Use 10 gauge copper wire.
Use a UL listed strain relief.
3=
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal (silver).
Install 3A" conduit connector into the hole below the terminal
block opening. Connect flexible metallic conduit and tighten
connector screw. Install direct wire cable through the flexible
metallic conduit.
L
J
Ground wire (green or bare wire) must be connected to
green ground connector.
......._ g
Connect remaining 2 supply wires to remaining
2 terminals (gold).
Securely tighten
all electrical connections.
A. Conduit connector
Failure to do so can result in death, fire, or
electrical shock.
B. Dryer cabinet
C. Connector screw
4=
Direct wire cable must match power supply (4-wire or 3-wire)
and be:
[]
Flexible armored cable or nonmetallic sheathed copper cable
(with ground wire), protected with flexible metallic conduit. All
current-carrying wires must be insulated.
[]
10-gauge solid copper wire (do not use aluminum).
[]
At least 5 ft. (1.52 m) long.
Direct Wire,
Four-wire electrical
to
connection:
I °_r_ e_jof /
_
-_ _
5" (127mm) _
fromendof cable.Leavegreenor bare
Shape ends
ground wireat 5" (127 mm). Cut11/2"
ofwiresinto (38 mm) from3 remaining wires. Strip
Strip
5" (127
mm) of
a hook.
insulation
back1"
(25outer
cm). covering
A. s/4"(19 mm) conduitconnector
B. Neutral(whiteor center)
C. Groundwire (greenor bare)
D. lO-gauge,3 wirewith groundwire in
flexiblemetallicconduit
Complete installation following instructions for your type of
electrical connection:
• Four-wire (recommended
method)
Three-wire (if four-wire is not available)
5.
Remove the center terminal block screw.
6.
Remove the appliance neutral ground
wire from the external ground conductor
screw. Fasten under center, silvercolored terminal block screw.
7. Connect the ground wire (green or bare)
of the direct wire cable to the external
ground conductor screw. Tighten screw.
8. Place the hooked end of the neutral wire
(white or center) of the direct wire cable
under the center screw of the terminal
block (hook facing right). Squeeze hook
end together. Tighten screw.
9. Place the hooked ends of the other
direct wire cable wires under the outer
terminal block screws (hook facing right).
Squeeze hooked ends together. Tighten
screws.
10. Insert tab of the terminal block cover into
slot of the dryer rear panel. Secure cover
with hold-down screw.
F
E¸
D
A. External ground conductor screw
B. Appliance neutral ground wire
C. Center terminal block screw
D. Outer terminal block screws
E. Neutral (center wire)
F. Green or bare ground wire
17
DirectWire,
Three-wire electrical
connection:
Use this method where local codes permit
connecting neutral ground wire to
neutral wire:
5.
Loosen or remove the center terminal
block screw.
6.
Three wire with ground wire: green or bare
wire cut short. Wire is not used. Dryer is
grounded through neutral conductor.
A
to
disconnect
box
1" (25 mm)
of wires
strippedof
insulation
Place the hooked end of the neutral wire
(white or center) of the direct wire cable
under the center screw of the terminal
block (hook facing right). Squeeze
hooked end together. Tighten screw.
7. Place the hooked ends of the other
direct wire cable wires under the outer
terminal block screws (hook facing right).
Squeeze hooked ends together. Tighten
screws.
8.
_
Insert tab of the terminal block cover into
slot of the dryer rear panel. Secure cover
with hold-down screw.
Use this method where local codes do
not permit connecting neutral ground
wire to neutral wire:
C
(89 mm)
Shape ends
of wiresinto
a hook.
Strip 31/2'' (89 mm) of outer
covering from end of cable.
Strip insulation back 1" (25 mm).
If using 3 wire cable with ground
wire, cut green or bare wire even
with outer covering.
A. s/4"(19 mm) conduit connector
B. Neutral (white or center)
C. lO-gauge, 3 wire with ground wire in
flexible metallic conduit
5.
Remove the center terminal block screw.
6.
Remove the appliance neutral ground wire
from the external ground conductor screw.
Connect the appliance neutral ground wire
and the neutral wire (white or center) of the
direct wire cable under the center, silvercolored terminal block screw. Tighten
screw.
7. Connect the other wires to outer terminal
block screws. Tighten screws.
8. Insert tab of the terminal block cover into
slot of the dryer rear panel. Secure cover
with hold-down screw.
9. After reattaching the terminal cover,
connect a separate copper ground wire
from the external ground connector screw
to an adequate ground.
If codes permit and a separate ground wire is
used, it is recommended that a qualified
electrician determine that the ground path is
adequate.
2.
1.
2.
1=
18
Using a 4" (102 mm) clamp, connect vent to exhaust outlet in
dryer. If connecting to existing vent, make sure the vent is
clean. The dryer vent must fit over the dryer exhaust outlet
and inside the exhaust hood. Make sure the vent is secured to
exhaust hood with a 4" (102 mm) clamp.
A. External ground conductor screw
B. Center terminal block screw
C. Outer terminal block screws
D. Neutral (center wire)
E. Appliance neutral ground wire
A .........
C
A. Separate copper ground wire
B. External ground conductor screw
C. Appliance neutral ground wire
D. Center terminal block screw
E. Outer terminal block screws
F. Neutral (center wire)
Plug in dryer or reconnect power.
3. Check dryer operation (some accumulated
the timer due to factory testing).
time may be on
Insert coins in slide and press slide in slowly. (Operating time
will accumulate per number of coins and type of timing cam
used.) Push START/RESTART button. Using a full heat cycle
(not the air cycle), let the dryer run for at least five minutes.
Dryer will stop when time is used up.
Move dryer into final position. Do not crush or kink vent.
Make sure dryer is bevel.
With dryer in final position place level on top of the dryer, first
side to side; then front to back. If the dryer is not level, adjust
the legs of the dryer up or down until the dryer is bevel.
C
NOTE: Dryer door must be closed for dryer to operate. When
door is open, dryer stops, but timer continues to run. To
restart dryer, close door and push START/RESTART button.
4.
If drying time is too long, make sure lint screen is clean.
5.
Now start the dryer and allow it to complete a full heat cycle
(not air cycle) to make sure it is working properly.
CHANGINGTOA 30- OR 60-MINUTETIMINGCAM
..............
A. Ratchettooth
B. Timir_gcam
Electrical Shock Hazard
c D ive
lug
D. V-shapednotch
Disconnect power before making cam changes.
Failure to follow these instructions
or electrical shock.
D
_.\
k%\\\
_X_
,
Source Exif Data:
File Type : PDF
File Type Extension : pdf
MIME Type : application/pdf
PDF Version : 1.2
Linearized : No
Page Count : 36
Page Layout : SinglePage
Page Mode : UseNone
Producer : Goby Monitor Application version 4, 0, 0, 13
Create Date : Wed Feb 11 04:33:18 2009
Author :
Title :
Subject :
EXIF Metadata provided by EXIF.tools