MEIAN Technology ST-IIIB ALARM CONTROL PANEL User Manual
Shenzhen Meian Technology Co.,Ltd . ALARM CONTROL PANEL
User Manual
ST-IIIB user manual P/N 20130320-1 U ser 册 手 品manual 产 Brief Dear customer: Congratulations on purchasing you new security systeman thank you for the confidence you have shown in us.You have chosena high -quality. Product that has been produced,tested and packed wthegreatest care.Please familiarize yourself with these instructions before atte mpting operation will only been sure if it is fitted properly.We hope your new security system will bring you lasting pleasure. U ser 册 手 品manual 产 Content Chapter I Introduction Chapter 2 Installation and Connection 2.1 Installation 2.2 Connection(N.O. N.C) 2.3 Install wired detector 2.4 Intall wereless detector Chapter 3 Keybad and Operation 3.1 About panel 3.2 Basic operation 3.3 Flashes when phone line cut 3.4 Host arm and disarm 3.5 Alarm procedure Chapter IV Voice alarm receiving and GSM control 4.1 Remote phone control 10 11 11 4.2 Alarm receiving phone operation 11 4.3 GSM remote operation 12 4.4 GSM alarm receiving 12 4.5 GSM control via SMS Chapter IV Voice alarm receiving and GSM control 12 13 5.1 Set system clock 13 5.2 Set user password 13 5.3 Set voice phone 13 Chapter VI System Setting 14 6.1 Set password 14 6.2 Set CMS number 15 6.3 Set voice phone 16 6.4 Set system options 17 6.4.1 Set system clock 17 U ser 册 手 品manual 产 6.4.2 Set entry delay 18 6.4.3 Set exit delay 6.4.4 Set siren time 6.4.5 Set ring times 18 18 18 6.4.6 Set detector loss inspection 6.4.7 Set arm/disarm tone 6.4.8 Set arm/disarm report 6.4.9 Set others 6.4.9.1Set emergency alarm siren type 19 19 20 20 20 6.4.9.2 Ac off inspection time setting 6.4.9.3 Magnetic contact inspection 21 21 6.4.9.4 Check wireless detector tamper 6.4.9.5 Set force arm 6.4.9.6 Set telehpone line disconnect remind 6.4.9.7 Set zone alrm times 6.4.9.8 Set listen-in time 6.4.9.9 Set AC off remind 6.5 Manage wireless device 6.5.1 Set remote control 6.5.1.1 Enroll remote control 6.5.1.2 Enter remote control code 6.5.1.3 Delte remote control 6.5.2 Set detector 6.5.2.1 Detector coding 6.5.2.2 Enter detector code 6.5.2.3 Delete detector 6.5.3 Set appliance switch 6.5.3.1 Enroll appliance switch 6.5.3.2 Delete appliance switch 6.5.4 Enroll wireless siren 6.5.4.1 Enroll wireless siren 6.5.4.2 Delete wireless siren 6.6.5 Set door bell 6.5.5.1Enroll doorbell 6.5.5.2 Delete doorbell 21 21 22 22 22 23 23 23 23 24 24 24 24 25 25 25 25 26 26 26 26 27 27 27 U ser 册 手 品manual 产 6.6.1 Set zone attribution 6.6.2 Set zone siren type 6.6.3 Set wired zone loop type 6.6.4 Set wired zone response speed 6.6.5 Set related zone 6.7 System maintance 28 28 28 29 29 30 6.7.1 Set timing operation 31 6.7.2 Recording 31 6.7.3 Play recording 31 6.7.4 Set programmable output port 31 6.7.5 Delete system events 32 6.7.6 Restore to factory default 32 6.8 Set GSM module 6.9 Advanced setting options 32 34 6.9.1 GPRS enable and disable 6.9.2 Set sever IP address 6.9.3 Set sever port 35 35 36 6.9.4 Set user ID 6.9.5 Set user password 36 36 6.9.6 GSM SMS language 36 6.9.7 Delay zone tone source options 37 6.9.8 Handshake tone input signal intensity 37 6.9.9 DTMF output signal intensity 37 6.9.10 Set LCD standby brightness 37 6.9.11 Alarm event retain time Chapter VII technical specification 7.1 General data 7.2 Physical performance Chapter VIII maintenance 8.1 Regular test 8.2 The cleanliness of control main machine Chapter VX limitation of the products 38 39 39 39 40 40 40 40 User 册 手 品manual 产 Chapter I Introduction 1.1 Function Introduction I 、Alarm mode: with PSTN and GSM network alarm, GSM network with GPRS function(GPRS function is for China market only), remote arm and disarm panel through CMS or SMS CID protocol, SMS notification, the priority of PSTN and GSM network is Optional. 2、With a new large-screen, full-touch buttons, LCD graphic display steps, work status,Alarm process easy and intuitive. 3、The full English voice prompting operation: all local or remote operation, alarm information, event log view. 4、GSM-hook and voice telephone with intercom function. 5、All alarm information can be programmed for the following settings: 0 does not send any information 1,Send only SMS 2,Only call users 3,SMS + call user 4, CMS only 5 ,CMS + SMS. 6,CMS + call user 7. CMS + SMS + call user 6、Sleep mode: Under sleep mode, all the lights, backlight, voice and remind tone are disabled. 7、Alarm panel under idle status is equivalent to a cellphone, you can call through the GSM network for balance inquiries 8、The associated zone: 4 groups associated zone, three kinds of association patterns, can effectively reduce false alarm or for other functions. 9、PGM output: With a programmed output port, followed by five kinds of alarm events output. 10、The doorbell Audio Optional: 1. Ding Dong 2 Welcome 3. Recording 4. Dee-Dee~ 11、Remote phone operation: dialing by telephone offsite, after password verification, you can arm, disarm, listen-in premise, system status query and electrical switches controls and other operations. 12、Voice Alarm: When panel alarm, it will automatically dial the preset user phone numbers to report alarm information then you can remote control the panel after enter user passwords. U ser 册 手 品manual 产 13、Wireless zones, each wireless zone can automatically learn the codes or be coded manually via the keyboard. 14、8 wired zones, User can set the circuit type and speed of response, support N.O, N.C. 15、Enable enroll total 8 wireless remote,8 electronic switch,1 pc of wireless doorbell and Unlimited for quantity of one way wireless siren. 16、 Follow me phone #,two for CMS,four for private alarm receiving. 17、Status inspection function:Enable record and inquiry 120 alarm event messages.Like the time when happens anti-tam per alarm,detector alarm, tel-line off,arm,disarm,system setting,battery low volt age etc.And also can inquiry the zone number and alarm type. 18、Timing arm and disarm: 4 sets of timing arm and disarm time. 19、Electrical switches control: User can remote switch on/off via phone or SMS, also can be controlled manually through the local alarm panel. 20、Zone programmable: factory preset for each zone type. Users can modify all the zone type according to the actual needs . 21、Clock: Built-in full automatic calendar clock, set to local time consistent 22、Password access management: the panel has one administrator password 16 user password, The administrator password primarily for system administrators to set up the alarm system; The user passwords for users in the day-to-day use such arm/ disarm,remote operation. The administrator password, user password can be freely modified. 23、For CMS networking alarm, depending on the number of users, the user can set four, six or eight user codes(account number). 24、Zone type identification:After an alarm is triggered, the alarm zone number displayed on the LCD screen of the panel, also can send the detailed report to CMS which includes alarm locations and zone types. 25、Al-proof function:If try to cut off the wire between wered detector and panel or cut off the tel line which. U ser 册 手 品manual 产 26、The tampering alarm: cut the cable between wired detectors and the panel will trigger larm, the telephone line cut will autom atically trigger siren alarm. When someone deliberately dismantled the panel, it will alarm when triggering tamper switch at the back of the panel. 27、Timing arm/disarm:Enable set 4 group time arm/disarm time. 28、CMS communications test: The panel will send a message to CMS at the pre-set time interval to inspect the communicaiton if normal. 29、Siren options:Built-in siren, external wired siren, Wirelss siren. All sirens can be programmed as enabled/disbale when alarms. 30、The voice speaker volume adjustment: adjust the volume by a rotary switch on the panel. 31、Wireless repeater function:can extend the distance between the detector and the panel by adding a wireless repeater of our company. 32、The wireless detector low battery prompted:Detectors will send status report to the panel every 1-3 hours, the corresponding zone number and the battery voltage symbol will be displayed on the LCD screen and also will report to CMS. U ser 册 手 品manual 产 Chapter 2 Installation and Connection 2.1 Installation 1. Fix the bracket to the wall and hang the pane to the bracket 2. The large metal objects can not be placed around the panel, so as not to affect the wireless signal. 3. Make sure to place the panel within the wireless range of all wireless accessoris and pay attention to the hidden 2.2 Connection(N.O. N.C) As pictures N.C N.O NO NC 10K 10K NO 10K NC 10K PGM GND Z33 Z34 GND Z35 Z36 Z37 Z38 GND Z39 Z40 DC15V/2A Power LINE TELL Voice volume knobs Here only introduce the zone 33, 34, 37, 38. The other zones please refer to the above. 2.3 Install wired detector 2.3.1The wired zones is disabled factory default. when to use wired zones please enable the zones firstly.When wired zones is in trouble, the panel will voice prompt "operation fails, Zone trouble” if users try User 册 手 品manual 产 To arm the panel. The zone number will be also display on the LCD screen. At this time arm system is not allowed unless you force arm. 2.3.2 The control pane can power 15V, 100mA to detectors. The max curent is 100mA. Do not exceed 100mA, otherwise please use extra power supply. 2.4 Intall wereless detector 2.4.1 As the detector`s manual says,install coded detector in the area 150m from the control panel.Please test and make sure detector can work with control panel normally. 2.4.2 Wireless repeater function:when wireless detector is too far from the panel or some occluders between panel and detector which disable the panel receivethe signal from wireless detector.Now you can choose our made wireless repeater to achieve wireless signal relay trans mitting. Chapter 3 Keybad and Operation 3.1 About panel Disarm Fault Alarm LCD screen Intercom/monitor hole Arm Stay/on turn key Key machine Protection /return button Event query /under turn key Set the keys Enter key A light hole U ser 册 手 品manual 产 Arm led: Light on under armed status, Light flashes under stay status. Disarm led: Light on under disarmed status Trouble led: Light on when with zone trouble. Light flashes when AC cut. Alarm led: Light flashes when alarm. 1 :Press 3 seconds to tirgger fire alarm 21 :Press 3 seconds for medical help 31 :Press 3 seconds for SOS 41 :Press 3 seconds then enter user code to enable or disable delay zone doorbell(Refer to page 36) 51 :Press 3 seconds then enter user code to enable or disable PGM output(refer to page 30) 61 :Press 3 seconds to enter or exit sleep mode. :Press 3 seconds then enter user code to enable or disable eletrical switch. 81 :Press 3 seconds then enter user code to bypass zones or activate zones. 9 :Press 3 seconds then enter user code to proceed normal testing, siren testing and walk testing. 1 :Press 3 seconds to make phone call through GSM, the longest 10 talk time is 240 seconds. the call will be interrupted when alarm occurs. Sleep mode: all led indicators, backlight, voice, remind tone will be disabled under sleep mode, The panel will exit sleep mode automatically when users enter system setting or when alarm occurs. Bypass zone: bypassed zones means zones disabled. The bypass will be restored when users disarm systems under home armed or armed status. Communication test: To test the communication between the panel and the CMS if normal Siren test: to test if siren working normal Walk test: to test if the detectors are working normally with the panel and alarm User 册 手 品manual 产 3.2 Basic operation Factory default Adminitrator password: 012345 16 User passwords, NO. 01 factory default is 1234. No. 02-16 of the user password is blank and can not enter the user setting untill user set the password. Disarm: User password[1234]+DISARM Home arm: Home arm key Arm: Arm key Event log: inquiry key Shutdown operation: AC power-off state ( # press and hold for more than 3 seconds) + user password [1234]+ # Enter system setting: press and hold for more than 3 seconds+ adminstrator password [012345]+ # Enter user setting: Press and hold for more than 3 seconds+ user NO. (01) +user password(1234)+ # Zone inspection: Not insepct wired zones within one minutes of panel power up Password reset: Enter 000000 to enter system setting menu within one minute of panel power up. 3.3 Flashes when phone line cut. Light on when phone line is normal. Icon Meaning Icon Meaning GSM signal strength GSM is enabled Telephone line Left behind Detector low battery Disarm PANEL low battery Arm Alarm Enable GPRS Voice prompts U ser 册 手 品manual 产 Flashes when phone line cut. Light on when phone line is normal. Flashes when GSM not ready, Light on when GSM is normal. Flashes when GPRS disconnected with CMS. Light on when GPRS is connected well with CMS. Flashes under sleep mode. Light on uder normal working mode. Zone 5 alarm Zone 5 detector lost Zone 5 trouble Zone 5 low battery Zone 5 bypass The alarm zone number will still be displayed on LCD screen after first disarm when alarm accurs, returned to normal screen display only users disarm twice. 3.4 Host arm and disarm ☆ Arm ☆ Disarm ~DI~ DI ~ ~DI~ DI ~ Press the key for arm away on remote or the keypad,then you hear"system armed,please exit the protection area" there will be “Dee-dee”sound to confirm the system is armed successfully. Press the disarm key on the remote or enter your user password on the keypad,then you will hear"dee"and voice"system disarmed",then you have disarm successfully. U ser 册 手 品manual 产 ☆ Home Arm ☆ Panic ~DI~ DI ~ ~DI~ DI ~ Press the key for home arm on the remote or "HOME"key on the keypad, then you will hear "s ystem stay " And it display home arm icon on the LCD screen. Press the panic button on remoter,or press" 3 " key on panel for 3 seconds. The codes of arm/disarm via different ways: Arm/disarm via keyfobs: 1-8 keyfobs----#40-47 Arm/disarm via user codes: 1-16 user codes---#01-16 Arm/disarm via phone call: 1-4 user phone number---#60-63 Arm/disarm via CMS: #97 Arm/disarm via home arm key or arm key in panel: #98 Auto arm/dsiarm via auto timer or key zone: #99 U ser 册 手 品manual 产 3.5 Alarm procedure Tele Telephone 1st 2nd telephone Cell phone 3rd 4th 3.The panel will dial 1-4 telephone numbers as preset.If more than 4 numbers,the panel will ire start with second telephone number, then 3,4... Alarm software Alarm situation found, start to send message 1.The detector activated send alarm infor mation to alarming center. CMS 110 alarm center 2.The panel use Ademco Contact ID to send ire le ss alarm information to alarming center. If the panel got confirmation from center, then alarm successfully.Otherwise, the panel will repeat alarm.The alarm information will be display and reslove by the alarm center computer software. 10 U ser 册 手 品manual 产 Chapter IV Voice alarm receiving and GSM control 4.1 Remote phone control User can remote control the system by phone call, after the preset ringing times then panel will off hook the phone then enter the 4 digit user codes according to voice prompting and operate as per the voice prompting. Telephone line The phone rings is 7 times, after 7 times ring, the panel will off-hook automatically. User call landline phones 12 13 Please enter password Press 1 to arm system Press 2 to disarm system Press 3 to Stay arm Press 4 to check system status Press 5 to appliance switch control Press 6 to control programmable output port Press 0 to Disconnect 11 14 Then enter user code according to voice prompting( the factory default user code is 1234) 4.2 Alarm receiving phone operation When alram, the panel will dial the pre-set voice phone number, when the user pick up the call, they will hear the voice prompting as below, if not press 1 to cancel the alarm or press 4 to disarm the system, after off-hook, the panel will call other preset voice phone numbers . The panel will dial the preset voice phone number when alarm occurs The user pick up the call Play the recorded voice message first, then : Press 1 to cancel alarm Press 2 to check alarm event Press 3 to arm system Press 4 to disarm system Press 5 to Stay arm Press 6 to enable siren Press 7 to listen-in Press 8 to control programmable output port Press 0 to Disconnect 11 U ser 册 手 品manual 产 4.3 GSM remote operation ( talk-back function added) When alarm occurs, GSM will call the preset voice number, when pick up the call,enter 4 digit user code, then voice prompt: Press 1 to arm system, Press 2 to disarm system, Press 3 to Stay arm, Press 4 to check system status, Press 5 to appliance switch control, Press 9 to talk-back, Press 0 to Disconnect. 4.4 GSM alarm receiving (talk-back function added) When alarm occurs, it will send SMS first, then call the preset voice number, when pick up the call, it will play the recorded voice message first, then voice prompt: Press1 to cancel alarm, Press 2 to check alarm event, Press 3 to arm system,Press 4 to disarm system, Press 5 to Stay arm, Press 6 to enable siren, Press 7 to listen-in, Press 8 to con trol programmable output port, Press 9 to talk-back, Press 0 to Disconnect. 4.5 GSM control via SMS Arm command: password:1234 system arm Disamr command: password:1234 system disarm Stay command: password:1234 system home Cancel alarm command: password:1234 system cancel Status checking command: password:1234 system status Enable programmable output port command: pasword:1234 pgm open Disable programmable output port command: password:1234 pgm close Enable appliance switch command: password:1234 switch open X(X=1-8 on behalf of appliance switch number) Disable appliance switch command: password:1234 switch close X(X=1-8 on behalf of appliance switch number) Set apn: password:1234 apn: " aaa " password:1234 user: "bbb " Set ID: Set password: password:1234 pwd: "ccc " Note: the factory default user code is 1234, when arm successfully, SMS auto reply”arm successfully”, if the password is correct, the command is not correct, SMS will reply” operation failure”, if the password is not correct, no SMS reply. 12 U ser 册 手 品manual 产 Chapter IV Voice alarm receiving and GSM control Press[*] for 3 seconds 1 2 3 4 Set system clock Set user password Set voice phone 5.1 Set system clock For example: set system clock as : 22:59:36 22/12/2012 Press[*] for 3 seconds Enter passord + 1 Please enter system clock, pressconfirm key tosave,press back key toexit. + 5 9 + 3 Min 4 + # + 1 2 + 2 + 2 + 6 + # Sec on screen According to flash of Y.M.D.H.Min.Sec on screen, enter 12.12.22.22.59.36 by turn, also can press [UP] [DOWN] key to move cursor. 5.2 Set user password For example: Set No.16 user pasword as 5678 Press[*] for 3 seconds Enter passord + 1 Please enter the serial number of your modified password, confirm key to confirm,press back key to exit. + 5 4 + # + 2 6 + # Enter password, press confirm key to save, press back key to exit. 8 + # Note: Can set 16 user passwords, corresponding password No. from 01 to 16, Only No.1 password can enter user setting. 5.3 Set voice phone (refer to page 15) 13 U ser 册 手 品manual 产 Chapter VI System Setting Press[*] for 3 seconds 0 1 2 3 4 5 6.1 Set password Set GSM Set advanced options Set password Set CMS number Set voice phone Set system options Set wireless devices Set zone System maintenance Press[*] for 3 seconds 0 1 2 3 4 5 1 # Then operate according to the voice prompt as below. Set password [1]Set Admin password Enter password, press confirm key to save, press back key to exit. X X X # The setting is saved [2]Set user password Please enter the serial number of your modified password, confirm key to confirm, press back key to exit press confirm key to save, X X X # Enter password,press confrim key to save, Press back key to exit X X X # The setting is saved Note: 1. password setting include “user password” and “ administrator password” password”, user password mainly use to disarm the system, it is a private key for remote controlling, “administrator password” is the sole password to set the system. 14 U ser 册 手 品manual 产 2.Administrator password is 6 digit, user password is 4 digit, can set 16 user passwords, corresponding password No. from 01 to 16, but No.2-16 password can’t enter user setting. 3.If forgot the password, when the alarm is powered on, for the first minute,the administrator password is 000000. For example: Set admin pasword as 888888 Press[*] for 3 seconds Enter password + 1 # 8 8 8 8 8 8 0 1 2 3 4 5 Enter password,press confirm key to save, press + back key to exit 1 # Note: 1.Above base on the correct operation, if incorrect operation occurs, please press back key to back previous menu to reset. 2.The factory default of admin password is 9876, user password is 1234, if you have modified the password, please refer to the new password. 6.2 Set CMS number Press[*] for 3 seconds 0 1 2 3 4 5 2 # Then operate according to the voice prompt as below: Set CMS [1] Set CMS phone number 1 # [2] Set CMS phone no.2 2 # Please enter phone number, press * key to delete, Long press 1, dialing pause 1 second,press confirm key to save, press back key to exit. X X X # The setting is saved [3] Set User Number 3 # [4] Set CMS dialing times 4 # [5] Set CMS communication test interval time 5 # Please enter account No. press confirm key to save, press back key to exit Please enter dialing times, press confirm key to save, press back key to exit Please enter communication inspection interval time, 0 for disable, press confirm key to save, press back key to exit X X X # X X X # X X X # The setting is saved The setting is saved The setting is saved 15 U ser 册 手 品manual 产 Note: 1.The user code is the identification code in CMS setting, CMS 1 and CMS 2 use the same user code; dialing times can be set 1-15 , communication inspection interval time can be set 0-999 hours, the common setting is 24 hours. 2.When set phone number, long press 1, display the letter P, means pause 1 second when dialing, when the telephone line which connect to the alarm panel is sub-line, need a pause dialing. 3.For GSM, just recognize the number behind P, can make sure telephone and GSM dial the same number. For example: the sub-line connect to alarm panel, CMS number is 80808080, in this way, set CMS number like this 9P80808080, 9 is out code. Press[*] for 3 seconds Enter password + 0 1 2 3 4 5 2 # Please enter phone number, press * key to delete, Long + 9 1 8 0 8 0 8 0 press 1, dialing pause 1 second, press confirm key to Press[1] key for 3 seconds. save, press back key to exit. 1 # 8 0 6.3 Set voice phone Press[*] for 3 seconds 0 1 2 3 4 5 3 # Then operate according to the voice prompt as below: Set voice phone [5] Set voice phone dialing times [1] Set voice phone 1 1 # [2] Set voice phone 2 2 # [3] Set [4] Set voice phone 3 voice phone 4 3 # Please enter phone number, press * key to delete, Long press 1, dialing pause 1 second, press confirm key to save, press back key to exit. X X X # The setting is saved 16 4 # [5] Set voice phone dialing times 5 # Please enter dialing times, press confirm key to save, press back key to exit. X X X # The setting is saved [6] Set voice phone password inspection 6 # 1.Enable 2.Disable X X X # The setting is saved U ser 册 手 品manual 产 Note:1.dialing times can set 1-15 2.When panel call user’s phone, if you enable password check, it will prompt enter user password when pick up the call. For example: Set voice phone No.3 is 12345678 Press[*] for 3 seconds 0 1 2 3 4 5 Enter password + Please enter phone number, press * key to delete, Long press 1, dialing pause 1 se cond, press confirm key to save, press back key to exit. 3 # 1 2 3 4 5 6 7 8 3 # 6.4 Set system options Press[*] for 3 seconds 0 1 2 3 4 5 4 # Set system clock Set entry delay Set exit delay Set siren time Set ring times Set detector loss inspection Set arm/disarm tone Set arm/disarm report Set others 6.4.1 Set system clock For example: Set system time to 22:59:36 22/12/2012 Press[*] for 3 seconds Enter password + Please enter system clock, press confirm key to save, press back key to exit. 0 1 2 3 4 5 1 2 1 2 2 2 4 # 2 2 1 # 5 9 Min + 3 6 + # Sec on screen According to flash of Y.M.D.H.Min.Sec on screen, enter 12.12.22.22.59.36 by turn, also can press [UP] [DOWN] key to move cursor. 17 U ser 册 手 品manual 产 6.4.2 Set entry delay When trigger alarm, the panel will give delay alarm time(default setting is 10s) For example: Set entry delay to 20seconds Press[*] for 3 seconds Enter password + Please enter entry delay time, press confirm key to save, press back key to exit 0 1 2 3 4 5 0 2 0 4 # 2 # Enter 3 digit number from 0-255, add 0 if less than 3 digit. Note: Entry delay is just effective for delay zone. Other zone types can’t enter delay. 6.4.3 Set exit delay After user armed the system, it is convenient for user to exit the area after arm successfully.( the default setting is 10seconds) For example: Set exit delay time is 20s Press[*] for 3 seconds Enter password + Please enter exit delay time, press confirm key to save, press back key to exit 0 1 2 3 4 5 0 2 0 4 # 3 # Enter 3 digit number from 0-255, add 0 if less than 3 digit. 6.4.4 Set siren time :The siren ring time after alarm is triggered( the default setting is 5 minutes) For example: Set siren time is 10 minutes Press[*] for 3 seconds Enter password + 0 1 2 3 4 5 Please enter 0 to 30 minutes siren time, press confirm key to save, press back key to exit 1 0 4 # 4 # 6.4.5 Set ring times User remote control alarm panel, dail the preset phone number, the panel will off-hook after phone ring times( the default setting is 7 times) For example: Set ring times is 5 18 U ser 册 手 品manual 产 Press[*] for 3 seconds Enter password + 0 1 2 3 4 5 Enter password.... Please enter ring times, if set as 0, the phone will not off hook, press confirm key to save, press back key to exit 0 5 4 # 5 # Enter 2 digit number from 0-15, add 0 if lower than 10. Note: The max. Ring times as per the local communication, if set 0, not off-hook. 6.4.6 Set detector loss inspection The alarm panel will inspect the detectors’ status or alarm info in this time interval, if not receive, it is determined that the detector is loss, the general setting is not less than 6 hours( the default setting is 0, disable this function) For example: Set detector loss inspection time is 8 hours. Press[*] for 3 seconds Enter password + 0 1 2 3 4 5 Please enter 0 to 99 hours detector loss inspection time, 0 for disable, press confirm key to save, press back key to exit 0 8 4 # 6 # 6.4.7 Set arm/disarm tone When user arm/disarm the system through remote control, if siren will sound or not for prompting.( the default setting is disabled) For example: Set siren with short sound when arm/disarm through remote control. Press[*] for 3 seconds Enter password + 0 1 2 3 4 5 Please choose arm/ disarm tone: 1. siren short sound 2. no voice, press confirm key to save, press back key to exit 4 # 7 # 19 U ser 册 手 品manual 产 6.4.8 Set arm/disarm report Set if arm/disarm report to CMS or not( the default setting is disabled) For example: Set arm/disarm report to CMS Press[*] for 3 seconds Enter password + 0 1 2 3 4 5 Please choose arm/disarm report: 1. enable, 2. disable, press confirm key to save, press back key to exit 4 # 8 # 6.4.9 Set others 0 1 2 3 4 5 4 # 9 # Set emergency alarm siren type Set AC off inspection time Enable magnetic contact inspection Check wireless detector tamper Set force arm Set telephone line disconnect remind Set zone alarm times Set listen-in time Set AC off remind 6.4.9.1 Set emergency alarm siren type( the default setting is mute) For example: set emergency alarm siren type is pedal point. Press[*] for 3 seconds Enter password + 20 1 # 0 1 2 3 4 5 Please choose zone siren type: 1.pedal point 2.pulse tone 3. mute, press confirm key to save, press back key to exit 4 # 9 # U ser 册 手 品manual 产 6.4.9.2 Ac off inspection time setting. When the AC power is off, delay to report to CMS(factory default delay time is 30 min) Example:set AC off inspection time as 15 min Press[*] for 3 seconds Enter password + 0 1 2 3 4 5 Plsease enter 0 to 255 minutes AC off duration time.press confirm key to save, press back key to exit. 2 # 4 # 0 1 5 9 # 6.4.9.3 Magnetic contact inspection: Set if the alarm panel show zone trouble on LCD screen or not when sperate the magnetic strip from transmitter. (Factory default disable the inspection) Example: enbale the magnetic contact inspection Press[*] for 3 seconds Enter password + 3 # 0 1 2 3 4 5 Please choose: 1. Enable magnetic contact inspection 2. Disable Press confirm key to save, Pressback key to exit. 4 # 9 # 6.4.9.4 Check wireless detector tamper: if the enable the checking when trigger the detector’s tamper , will trigger alarm. If disable the checking, it will not trigger alarm.(factory default enable the checking) Example: disable the checking of wireless detector tamper. Press[*] for 3 seconds Enter password + 4 # 0 1 2 3 4 5 Please choose : 1. Enable wireless detector tamper inspection, 2. Disable Press confirm key to save, Pressback key to exit. 4 # 9 # 6.4.9.5 Set force arm: if enabel set force arm, when there is zone trouble, the system can be armed and report the trouble zone’s bypass message to CMS. If disable the force arm, the system can not be armed(factory default is disable forem arm) Example: enabel force arm 21 User 册 手 品manual 产 Press[*] for 3 seconds Enter password + 5 # 0 1 2 3 4 5 Please choose: 1. Auto force arm 2. Forbid force arm via remote control. Press confirm key to save, pressback key to exit. 4 # 9 # 6.4.9.6 Set telehpone line disconnect remind(factory default delayed siren sound remind) Example : disable telephone line disconnet remind Press[*] for 3 seconds Enter password + 6 # 0 1 2 3 4 5 Please choose telephone line disconnect remind: 1. Siren delay remind, 2. Buzzer remind, 3 disable Press confirm key to save, Pressback key to exit. 4 # 9 # 6.4.9.7 set zone alrm times: if set the alarm alarm times as 1, when zone start alarm but the zone is trigger one time again, the panel will not make alarm. Example: set zone alarm times as 1 time Press[*] for 3 seconds Enter password + 7 # 0 1 2 3 4 5 Please choose zone alarm times: 1. no limited 2. 1 time Press confirm key to save, Pressback key to exit. 0 2 0 4 # 9 # 4 # 9 # 6.4.9.8 set listen-in time(factory default 10 sec) Example: set listen-in time as 20sec Press[*] for 3 seconds Enter password + 22 8 # 0 1 2 3 4 5 Please enter 10 to 255 seconds listen-in time Press confirm key to save, Pressback key to exit. U ser 册 手 品manual 产 6.4.9.9 Set AC off remind(factory default remind by SMS) Example:disable AC off remind Press[*] for 3 seconds Enter password + 9 # 4 # Please choose AC off remind: 1. SMS remind 2. Voice phone remind 3. Disable Press confirm key to save, Pressback key to exit. 0 1 2 3 4 5 9 # 6.5 manage wireless device Press[*] for 3 seconds 0 1 2 3 4 5 5 # Set remote control Set detectors Set appliance switch Enroll wireless siren Set door bell 6.5.1 set remote control Press[*] for 3 seconds 0 1 2 3 4 5 5 # 1 # Enroll remote control Enter remote control code Delete remote control 6.5.1.1 enroll remote control Example: enroll remote to the #3 remote in alarm panel Press[*] for 3 seconds Enter password + 1 # 0 1 2 3 4 5 Please enter the serial number of remote control + Press confirm key to save, Pressback key to exit. Enroll successful + 5 # 1 # Please trigger the remote control Pressback key to exit. Trigger arming key on the remote control 23 U ser 册 手 品manual 产 6.5.1.2enter remote control code Example: manaul enter the address code of remote 112113114 to the #8 remote in alarm pa Press[*] for 3 seconds Enter password + 2 # 0 1 2 3 4 5 Please enter the serial number of remote control. Press confirm key to save, Pressback key to exit. Please enter remote control Number Press confirm key to save, Pressback key to exit. 5 # 1 1 2 1 1 3 1 1 4 1 # 6.5.1.3 delte remote control Example: delete the # 5 remote Press[*] for 3 seconds Enter password + 0 1 2 3 4 5 Please enter the serial number of remote control to delete, enter 0 to delete all. Press confirm key to save, Pressback key to exit. 3 # 5 # 1 # 6.5.2 set detector Press[*] for 3 seconds 0 1 2 3 4 5 5 # 2 # Detector coding Enter detector code Delete detector 6.5.2.1 detector coding Example: auto code detector to # 9 detector in alarm panel Press[*] for 3 seconds Enter password + 1 # Please enter detector Number Press confirm key to save, Pressback key to exit. trigger the detector 24 0 1 2 3 4 5 0 9 5 # 2 # Please trigger the detector Pressback key to exit. Enroll successful + User 册 手 品manual 产 6.5.2.2 enter detector code Example: manual enter the address code of detector 011022033 to the # 7 detector in alarm panel Press[*] for 3 seconds Enter password + 2 # 0 1 2 3 4 5 Please enter detector Number. Press confirm key to save, Pressback key to exit. Please enter detector code Press confirm key to save, Pressback key to exit. 0 7 5 # 2 # 0 1 1 0 2 2 0 3 3 6.5.2.3 delete detector Example: delete the # 3 detector Press[*] for 3 seconds Enter password + 3 # 0 1 2 3 4 5 Please enter the serial number of detector to delete, enter 00 to delete all. Press confirm key to save, Pressback key to exit. 5 # 0 3 2 # 6.5.3 set appliance switch Press[*] for 3 seconds 0 1 2 3 4 5 5 # 3 # Enroll appliance switch Delete appliance switch 6.5.3.1 enroll appliance switch Example: auto the appliance to the # 1swith in alarm panel Press[*] for 3 seconds 1 # Enter password + 0 1 2 3 4 5 Please enter the serial number of appliance switch + Press confirm key to save, Pressback key to exit. Trigger appliance switch 5 # 3 # Please trigger appliance switch Pressback key to exit. Enroll successful + 25 User 册 手 品manual 产 6.5.3.2 Delete appliance switch Example: delete the # 4 appliance switch Press[*] for 3 seconds Enter password + 0 1 2 3 4 5 Please enter the serial number of appliance switch to delete, enter 0 to delete all Press confirm key to save, Pressback key to exit. 2 # 5 # 3 # 6.5.4 Enroll wireless siren 0 1 2 3 4 5 5 # 4 # Delete wireless siren 5 # Enroll wireless siren 6.5.4.1 Enroll wireless siren Press[*] for 3 seconds Enter password + 0 1 2 3 4 5 Please make wireless siren under coding status, then press confirm key to start coding. 1 # 4 # Make wireless siren under coding status + This is one way wireless siren Press confirm key to save, Pressback key to exit. Start siren coding, please operate as voice prompting Pressback key to exit. This is 2-way wireless siren Press confirm key to save, Pressback key to exit. NOTE: when dual-way wireless siren make tamper alarming, the LCD screen of alarm panel will display zone 41 alarming. 6.5.4.2 Delete wireless siren 按[*] 3秒 以 上 Enter password + 2 # 0 1 2 3 4 5 Delete wireless siren Press confirm key to save, + Pressback key to exit. Note: It is dual-way wireless siren deleted. 26 5 # 4 # U ser 册 手 品manual 产 6.6.5 Set door bell 0 1 2 3 4 5 5 # 5 # Enroll doorbell Delete doorbell 6.5.5.1Enroll doorbell Press[*] for 3 seconds Enter password + 1 # 0 1 2 3 4 5 Please trigger doorbell Pressback key to exit. Please trigger doorbell 5 # 5 # Enroll successful Note: can only learn a wireless doorbell, the trigger will be issued after the chink 6.5.5.2 Delete doorbell Press[*] for 3 seconds Enter password + 2 # 0 1 2 3 4 Delete doorbell Press confirm key to save, Pressback key to exit. 5 # 5 # 6.6 Sector Settings Press[*] for 3 seconds 0 1 2 3 4 5 6 # Set zone attribution Set zone siren type Set wired zone loop type Set wired zone response speed Set related zone 6.6.1 set zone attribution The type of zone attributuion is as below: 0)disable zone 3>inerior zone 6>fire zone 1> delay zone 4>emergency zone 7> key zone 2> perimeter zone 5> 24 hours zone 1.Zone attribution is the alarm type of the zone display on the alarm panel’ s LCD screen when the zone is triggered. When set the zone attribution as 0 is to disable the zone. The alarm panel will not make alarm when trigger this zone. 27 U ser 册 手 品manual 产 2.interior zone only trigger alarm when the zone is triggered under system at armed status. 3.delay and perimeter zone trigger alarm when the zone is triggered under system at armed or home arm status. 4.emergency zone, 24 hours zone, fire zone will trigger alarm when system at any status 5.wirelss zone can not set key zone type. When wired zone is set as keyzone, trigger the zone, system turn to disarm status. The zone restore, system turn to armed status. This is for access contron system. Example: set zone 39 as keyzone type Press[*] for 3 seconds Enter password + 0 1 2 3 4 5 Please enter the zone No. to modify. Press confirm key to save, Pressback key to exit. 3 9 6 # 1 # Please choose zone type: 0. Disable the zone 1. Delay zone 2. Perimeter zone 3. Interior zone + 4. Emergency zone 5. 24 hours zone 6. Fire zone 7. Key zone 6.6.2 set zone siren type(factory default is pefal point) Example set zone 23’s siren type as pulse tone Press[*] for 3 seconds Enter password + 0 1 2 3 4 5 Please enter the zone number to modify. Press confirm key to save, Pressback key to exit. 2 3 6 # 2 # Please choose zone siren type: 1.pedal point 2.pulse tone 3. Mute Press confirm key to save, Pressback key to exit. 6.6.3 set wired zone loop type(factory default EOL ) The options is as below: 1>EOL loop type: when the resistor value is 10k on the zone is normal, when the zone is open loop or shortcut trigger alarm 2>N/C loop type: zone shortcut is normal, open loop trigger alarm 3>N/O loop type: zone open loop is normal, shortcut loop trigger alarm 28 U ser 册 手 品manual 产 10KΩ NC NO 10KΩ EOL loop N/O wiring diagram EOL loop N/C wiring diagram Example: set zone 35 as N/O loop type Press[*] for 3 seconds 0 1 2 3 4 5 Enter password + Please enter the zone number to modify Press confirm key to save, Pressback key to exit. 3 5 6 # 3 # Please choose loop type: 1.EOL 2.N/C, 3.N/O Press confirm key to save, Pressback key to exit. 6.6.4 set wired zone response speed(factory default is 500 millisecond) Press[*] for 3 seconds Enter password + 0 1 2 3 4 5 Please enter the zone numbEr to modify Press confirm key to save, Pressback key to exit. 4 0 6 # 4 # Please choose loop response speed: 1. 500ms, 2. 10ms Press confirm key to save, Pressback key to exit. Note: Normall the detector’s response speed is 500 millisecond, high speed response detector like vibration detector is 10 millisecond 6.6.5 set related zone: zone 1+zone 2+related time+mode The options as belows 0>disable related zone mode 1>EXIT-ENTRANCE dual trigger mode: trigger zone 1 or 2 seperately will not trigger alarming. Trigger zone 1 first, then during the period of related time trigger zone 2, then both zone 1 and 2 trigger alarm.Trigger zone 2 first, then trigger zone 1 will not trigger alarm. 29 U ser 册 手 品manual 产 2>EXIT-ENTRANCE single trigger model: trigger zone 1, zone 1 make alarm. Trigger zone 2 first, then during the period of related time trigger zone 1, do not make alarm. Trigger zone 2, then do not trigger zone 1 during related time, then zone 2 make alarm. 3> Dual trigger alarm mode: trigger zone 1 or zone 2 only do not make alarm. During related time trigger zone 1 or zone 2, then zone 1 or zone 2 make alarm. Example: set zone 5 and zone 9 as greep #4 dual trigger mode related zone, related time is 120sec. Press[*] for 3 seconds Enter password + Eneter correlate group # , press confirm key to confirm or press back key + to exit setting. 0 5 0 1 2 3 4 5 6 # 5 # Enter the firstcorrelate zone # press confirm key to savesetting, or press back key to exit setting. Settingsaved, enter second related zone #, press confirm key to save setting or press back key to exit setting Setting is saved, press set relate time from 2 to 255sec, and press confirm key to save setting, or press back key to exit setting Setting is saved, pls choose relate mode. 0 disable relate mode , 1 entrance-exit dual trigger mode, 2 entrance-exit single trigger mode, 3 dual trigger mode. Press confirm key to save setting or press back key to exit. 0 9 1 2 0 NOTE: max set 4 group relate zone 6.7 system maintance Press[*] for 3 seconds 30 0 1 2 3 4 5 7 # Set timing arm /disarm Recording Play recoreding Set programmable output port Delete system log Restore to factory default U ser 册 手 品manual 产 6.7.1 Set timing operation Example: Set group No.3 as timing disarm at 8:30, and timing arm at 17:30 Press[* ] for 3 seconds Enter password + 0 1 2 3 4 5 Please enter timing arm /disarm group number 1 7 3 0 7 # 1 # Please enter timing arm time, 00 is invalid time.Press confirmkey to save, pressback key to exit. Please enter timing disarm time, 00 is invalid time. Press confirm key to save, + press back key to exit. 0 8 3 0 Hint: 4 groups of timing arm/disarm can be set according to the schedule of user. 6.7.2 Recording Press[* ] for 3 seconds 2 # Enter password 0 1 2 3 4 5 7 # Start to record when you hear “Bi” sound Hint: 15 seconds for recording time. And it will play recording as soon as the panel dial to the telephone No.as preset. 6.7.3 Play recording Press * for 3 seconds. Enter password + 3 # 0 1 2 3 4 5 7 # Play the recording 6.7.4. Set programmable output port: the voltage will change from 0V to 14.5V as soon as some events occurs. (Default is follow alarm output) Trigger events can be set as below 1. Follow alarm output 3. Follow AC power fault output 5. Password control output 2. Follow arm output 4. Follow communication fault output 31 User 册 手 品manual 产 For example: Set as password control output Press[*] for 3 seconds Enter password + 0 1 2 3 4 5 7 # Please select programmable output port follow event 1.Follow alarm output 2.Follow arm output 3.Follow AC power fault output 4.Follow Communication fault output 5.Password control output 4 # Hint: when setting as password control output, press key 5 for 3 seconds, then enter the user password, the programme output port will be open or closed. Voice phone or SMS also can open or close the outport. 6.7.5.Delete system events Press[*] for 3 seconds Enter password + 0 1 2 3 4 5 Please re-confirm to restore to factory default. Press confirm key to save, press back key to exit. 7 # 5 # 7 # 6 # 6.7.6.Restore to factory default Press * for 3 seconds Enter password + 0 1 2 3 4 5 Please re-confirm to restore to factory default. Press confirm key to save, press back key to exit. 6.8. Set GSM module Press[*] for 3 seconds The voice prompt will instruct you to proceed below operations. For example: Set enable GSM module, telephone line priority, Set GSM bill reminder time is 21st Dec. 2012. 32 0 1 2 3 4 5 8 # U ser 册 手 品manual 产 Set GSM module [1]Set GSM disabled/enabled Please choose 1> enable GSM 2> disable GSM, Press confirm key to save, press back key to exit. [2]Set GSM [3] GSM signal [4] Set GSM bill in priority display reminder time Please choose 1> GSM in priority 2> PSTN in priority, Press confirm key to save, press back key to exit. 1 # 2 # The setting is saved The setting is saved The maximum signal intensity can be displayed in LCD is 31, press back key to exit. Please enter SIM card expiry time, Press confirm key to save, press back key to exit. 1 2 1 2 2 1 # The setting is saved Hint: The alarm control panel will send SMS to cellphone as preset and remind you to recharge as you set GSM bill reminder time before or after ten days. 33 User 册 手 品manual 产 6.9 Advanced setting options Without voice prompt, programme address and the corresponding options as below table. 01 GPRS enable and disable 59 Sensor recovery 02 Set sever IP address 60 Sensor loss 03 Set sever port 61 System low battery 04 Set user ID 62 System AC loss Set user password 63 System AC recovery GSM SMS language 64 Zone bypass 07 Delay zone tone source options 65 Telephone line fault 08 Handshake tone input signal 66 Periodic test report intensity 67 Wireless zone loop trouble 05 06 09 DTMF output signal intensity 10 Set LCD standby brightness 11 Alarm event retain time 68 Wireless zone loop recovery 0 69 System battery recovery 50 System 00 zone 51 Delay zone 52 Perimeter zone 53 Interior zone 70 Communication trouble 71 Bypass cancel 72 Alarm cancel 73 Disarm 74 Armed stay 75 Armed 54 24 Hour zone 76 Panel programming changed 0 55 Emergency zone 77 System alarm failure 56 Fire zone 78 Telephone line recovery 57 Tamper zone 79 Communication recovery 58 Sensor low battery Programming address 50-79 are correspond to the options for the alarm content, the right of data are factory default. Set alarm data as below: 0. Do not send any information 1.Only send SMS. 2.Only telephone line 3.SMS+telephone line 4.Only upload to CMS 5.Upload to CMS+SMS 6.Upload to CMS+telephone line 7.Upload to CMS+SMS+telephone line 34 User 册 手 品manual 产 LCD display direction Programming address Data Data bit Press key up and down to check and modify the different data of the data bit. 6.9.1 GPRS enable and disable(1. Enable 2. Disable default is 2 ) For example: set enable GPRS Press[*] for 3 seconds Enter password LCD display 0 1 0 1 2 3 4 5 Programming Data address 9 # LCD display Hint: Priority to enable the GSM module before enable the GPRS 6.9.2 Set sever IP address For example: Sever IP address is 103.59.108.3 Press[*] for 3 seconds Enter password + 0 2 1 0 3 0 1 2 3 4 5 0 5 9 1 0 8 9 # 0 0 3 Less than 3 bits high zero. 35 U ser 册 手 品manual 产 6.9.3 Set sever port For example: Sever port as 80808 Press[*] for 3 seconds Enter password + 0 3 0 1 2 3 4 5 8 0 8 0 8 9 # 9 # 6.9.4 Set user ID For example: User ID as 50505050 Press[*] for 3 seconds Enter password 0 4 0 1 2 3 4 5 5 0 5 0 5 0 5 0 User ID must be 8 bits 6.9.5 Set user password For example: User password as 12345678 Press[*] for 3 seconds Enter password 0 5 0 1 2 3 4 5 9 # 1 2 3 4 5 6 7 8 User password must be 8 bits 6.9.6 GSM SMS language(1. Chinese 2. English Default is 1 Chinese) For example: Set GSM SMS language as English Press * for 3 seconds Enter password 36 0 6 0 1 2 3 4 5 9 # User 册 手 品manual 产 6.9.7 Delay zone tone source options 1. Dingdong 2. Welcome 3. Recording 4. Didi For example : Delay zone tone source as recording Press[*] for 3 seconds Enter password + 0 7 0 1 2 3 4 5 9 # Hint: In disarm mode, once delay zone triggered and above 4 voices will be generated. press key 4 for 3 seconds and input the user password can be open and close it.When the tone source is recording mode, the voice phone will not play the recording. 6.9.8 Handshake tone input signal intensity ( default is 60) For example: set it as 70 Press[*] for 3 seconds Enter password 0 8 0 1 2 3 4 5 7 0 9 # 6.9.9 DTMF output signal intensity(The default is 04) For example: set the DTMF output signal strength to 06 Press[*] for 3 seconds Enter password + 0 9 0 1 2 3 4 5 0 6 9 # 9 # 6.9.10 Set LCD standby brightness (default is 02) For example: Set it as 22 Press[*] for 3 seconds Enter password + 1 0 0 1 2 3 4 5 0 8 Brightness range: 0-10,Less than 2 bits high zero 37 User 册 手 品manual 产 6.9.11 Alarm event retain time When telephone line and GSM all fault, the alarm event will be retained in the preset time. Otherwise it will loss. After telephone line and GSM recovery, it will upload to the CMS. (default time is 10 mintus). For example: set the alarm information retention time is 255 minutes Press[*] for 3 seconds Enter password 1 1 0 1 2 3 4 5 2 5 5 Retain time :1-255 mintus.Less than 3 bits high zero. 38 9 # User 册 手 品manual 产 Chapter VII technical specification 7.1 General data 1.Power supply: 15V/2000mA 2.Built in rechargeable battery:11.1V/1000mah 3.System static current: <50mA(exclude wireless detector) 4.System alarming current: <300mA(exclude wireless high siren current) 5.System maximum output current: ≤100mA(supply wireless detector) 6.Frequency:433MHz/868MHz 7.Signal transmit distance: 100 to 150 meters (open area) 8.The method of alarming dial: DTMF GSM or GPRS 9.Communication protocol with CMS: Ademco Contact ID 10.DTMF dial frequency variation:,1.5% 11.Recording time:15s 7.2 Physical performance Operation temperature range: 0℃-45℃(32F-120F Storage temperature range: -20℃-60℃(-4F-140F) Relative humidity: 85% at 30℃(86F) Color: as box indicated. 39 User 册 手 品manual 产 Chapter VIII maintenance 8.1 Regular test Design of components of the system is to reduce maintenance cost, but still it is suggested that periodical check may be carried out. 8.2 The cleanliness of control main machine Main control panel may be stained by fingers or covered by dust after using for a while. Use soft cotton cloth or sponge to clean it, don't use any lubricant, liquid such as kerosene, acetone and strong gel which will damage appearance and the transparency of top window. Attention: don't use any lubricant, liquid such as kerosene, acetone and strong gel which will damage appearance and the top transparency of window. Chapter VX limitation of the products Although the products is a high standard products, there is also some limitation of them such as false alarm or no alarm. The reasons may be below: Lack of maintenance, the system needs maintenance and test regularly test the sensitive of the detector may decrease and the siren may not whistle.Lack of power supply if no power input and the back up power is not enough, the panel can not work normally.Telephone line false, if the telephone line is cut, the panel could not send alarm signals. Limitation of smoke detectors, if the smoke is far from the smoke detector, the detector could not alarm.If the intrude break in through some door or window not monitored. Or someone know how to make the system not work. 40 FCC WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help FCC Radiation Exposure Statement The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No XMP Toolkit : 3.1-702 Create Date : 2014:04:28 20:22:47+08:00 Creator Tool : CorelDRAW X5 Modify Date : 2014:06:18 09:41:02+08:00 Metadata Date : 2014:06:18 09:41:02+08:00 Format : application/pdf Creator : Administrator Title : ST-III 触摸屏(改)英文 Producer : Corel PDF Engine Version 15.0.0.486 Document ID : uuid:39739a96-60e1-4221-a9ed-e4ddc5bce1bb Instance ID : uuid:1e53c627-48e5-486b-a8b8-a446b8522c69 Has XFA : No Page Count : 46 Profile CMM Type : Lino Profile Version : 2.1.0 Profile Class : Display Device Profile Color Space Data : RGB Profile Connection Space : XYZ Profile Date Time : 1998:02:09 06:49:00 Profile File Signature : acsp Primary Platform : Microsoft Corporation CMM Flags : Not Embedded, Independent Device Manufacturer : IEC Device Model : sRGB Device Attributes : Reflective, Glossy, Positive, Color Rendering Intent : Perceptual Connection Space Illuminant : 0.9642 1 0.82491 Profile Creator : HP Profile ID : 0 Profile Copyright : Copyright (c) 1998 Hewlett-Packard Company Profile Description : sRGB IEC61966-2.1 Media White Point : 0.95045 1 1.08905 Media Black Point : 0 0 0 Red Matrix Column : 0.43607 0.22249 0.01392 Green Matrix Column : 0.38515 0.71687 0.09708 Blue Matrix Column : 0.14307 0.06061 0.7141 Device Mfg Desc : IEC http://www.iec.ch Device Model Desc : IEC 61966-2.1 Default RGB colour space - sRGB Viewing Cond Desc : Reference Viewing Condition in IEC61966-2.1 Viewing Cond Illuminant : 19.6445 20.3718 16.8089 Viewing Cond Surround : 3.92889 4.07439 3.36179 Viewing Cond Illuminant Type : D50 Luminance : 76.03647 80 87.12462 Measurement Observer : CIE 1931 Measurement Backing : 0 0 0 Measurement Geometry : Unknown Measurement Flare : 0.999% Measurement Illuminant : D65 Technology : Cathode Ray Tube Display Red Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Green Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Blue Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Author : AdministratorEXIF Metadata provided by EXIF.tools