MOELCA S R L 1504 AUTOMATIC EXTRACTOR OF EMOCOMPONENTS User Manual Rev 1 05
MOELCA S.R.L. AUTOMATIC EXTRACTOR OF EMOCOMPONENTS Rev 1 05
User Manual
ARCHIMEDE User Manual Revision 1.05 MOELCA s.r.l. Registered Office: Via E.Toti 101 Offices: Via del Lavoro 19 22070 Limido Comasco (CO) 031-3520153 3520279 3524739 Fax 031-3524732 E-mail info@moelca.it Manufacturer Responsibility The instructions for use may contain a declaration that the Manufacturer, the Assembler, the Installer or the Importer consider themselves responsible for instrument safety, reliability and performance only if: ⢠⢠⢠assembling, extensions, adjustments, changes or repairs are performed by qualified service personnel under his authorization; the instrument is operated in a room whose electrical system applies with the relevant prescriptions; the instrument is operated according to the instructions for use. The device complies with part 15 of the FCC Rules. Operation is subjected to the following 2 conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operationâ Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. COPYRIGHT All rights reserved. The contents of this document may not be reproduced, stored in a retrieval system, transmitted in any form or electronic mean, used for different aims without the prior written consent of MOELCA s.r.l. This document is subject to change without notice. While the utmost care has been taken for collection and verification of the documentation contained in the present manual, MOELCA s.r.l. assumes no responsibility deriving from the use of the same. MOELCA s.r.l. assumes no responsibility for people or companies involved in the creation and issuing of the present manual. Page 2 of 105 User Manual Revision 1.05 WARRANTY MOELCA s.r.l. certifies that the instrument is free from any defect when shipped from factory. The warranty covers the instrument and all its parts for a period of 12 months from delivery date. During the warranty period MOELCA s.r.l. will repair or replace free of charge (at its discretion and ex factory) the parts or units that prove to be defective. All parts or units replaced will become MOELCA s.r.l. property. The warranty is automatically voided in case of violations, changes, different use from that described in the instructions, wrong plugging in power mains, repairs performed by personnel not authorized by MOELCA s.r.l., accidental breakings due to transportation or falls, lack or deletion or modification of the serial number. In case of repairs not covered by the warranty, MOELCA s.r.l. or its representatives will draw up a quotation and provide for repair upon written acceptance of the customer. Service During the warranty period the instrument should not be modified or repaired by personnel not authorized by MOELCA S.r.l. For information about service please contact: Any repair after the warranty period should be performed by qualified personnel properly instructed by MOELCA s.r.l. User Manual Revision 1.05 Page 3 of 105 Revisions Log Manual Revision # Software Revision # Date Author 1.00 1.00 01/03/2006 C. Milani Original Document 1.01 1.08 21/07/2007 C. Milani Change in separation procedures and WLAN. 1.02 1.12 03/03/2008 C. Milani Modify like Fenwal suggestion. 1.03 2.00 06/06/2008 C. Milani FCC ID rules-IP41 1.04 2.20 24/06/2008 C. Milani Modify as PRS reference 1.05 2.25 10/01/2009 C. Milani Page 4 of 105 Changes Change in troubleshooting. User Manual Revision 1.05 SYMBOLS The following list contains symbols and marks used in this manual. Class I In this instrument the protection against direct and indirect contacts does not consist only of the basic insulation but, also of an additional safety measure. Instrument with applied part type B. CE mark certifying compliance with MDD 93/42 guideline. SN Symbol for âSERIAL NUMBERâ. Caution: please read attached documentation. Caution: keep hands off this area. Not ionized radiation. Discard separately. Manufacturer. User Manual Revision 1.05 Page 5 of 105 CONTENTS WARRANTY INTRODUCTION 1.1 Intended Use.............................................................................. 11 1.2 Key features............................................................................... 11 INSTALLATION 13 2.1 2.2 2.3 2.4 2.5 2.5.1 2.5.2 11 Unpacking Archimede .................................................................. 13 Positioning Archimede.................................................................. 13 Assembling scale, filter holders and antenna. .................................. 13 Switching on Archimede ............................................................... 14 Instrument Setup........................................................................ 15 Date and Time Procedures Setup Check 15 16 GENERAL DESCRIPTION 17 3.1 Upper Panel ............................................................................... 17 3.2 Front Panel ................................................................................ 17 3.2.1 3.2.2 18 19 3.3 Rear Panel ................................................................................. 20 3.4 Side Panel.................................................................................. 20 3.5 Meaning of Procedure Parameters.................................................. 21 3.6 Procedure Parameters Display....................................................... 24 3.7 Maintenance Display .................................................................... 24 3.8 Date and Time ............................................................................ 24 3.9 Scales ....................................................................................... 25 3.10 Manual Control of Plate Forward Moving ......................................... 25 3.11 Clamps Manual Control ................................................................ 26 USING ARCHIMEDE 27 4.1 4.2 4.3 4.4 4.5 4.6 Keyboard Backlight Display 4.6.1 4.6.2 4.6.3 4.6.4 4.6.5 4.6.6 4.6.7 4.6.8 4.6.9 4.6.10 4.6.11 Switching on .............................................................................. 27 System Self-check....................................................................... 27 Use as a scale............................................................................. 30 Use as a sealing unit.................................................................... 30 Use as manual separator .............................................................. 31 Separation Procedure .................................................................. 32 Questions PROCEDURE 1 T & T triple PPP or PRP + RCC. PROCEDURE 2 T & T quadruple PPP or PRP BC + RCC. PROCEDURE 3 Top & Bottom triple PPP+BC+RCC. PROCEDURE 4 Top & Bottom quadruple PPP+BC+RCC. PROCEDURE 5 Separation from PRP to PPP+PLT PROCEDURE 7 Single or Pool of Buffy for PLT + residual BC with filter PROCEDURE 8 Separation of Erythrocytes Washing PROCEDURE 10 [a]UMBILICAL CORD PROCEDURE 11 [b] ALIQUOTE SEPARATION PROCEDURE 13 [d] T & T for RCC diluted in Plasma + Predefined HCT. 33 34 39 44 49 54 59 64 69 74 79 SCALE CALIBRATION 85 DATA TRANSFER 87 6.1 WLAN ........................................................................................ 87 6.2 Firmware Update and Procedures Protocols ..................................... 87 6.3 Data transmission and reception ................................................... 88 6.3.1 6.3.2 Example of procedure data transmission: List of symbols used in the transmission protocol: TROUBLESHOOTING Page 6 of 105 90 90 91 User Manual Revision 1.05 CONTENTS 7.1 Errors and Possible Solutions ........................................................ 91 7.2 Errors with Archimede codes......................................................... 91 Maintenance 99 8.1 Daily Maintenance ....................................................................... 99 8.1.1 8.1.2 8.1.3 Cleaning Decontamination Monthly Maintenance 99 99 99 8.2 Yearly Maintenance ..................................................................... 99 8.3 Maintenance Recording ................................................................ 99 ACCESSORIES 101 10 DISPOSAL 11 10.1 Packing Material Disposal ........................................................... 103 10.2 Archimede Disposal ................................................................... 103 TECHNICAL FEATURES 105 PICTURES Picture 1: Parts included in the packing. Picture 2: Archimede display Picture 3: Screen shot âSelf Testâ Picture 4: Date and time menu. Picture 5: Date and time format list. Picture 6: Utility menu. Picture 7: Parameters procedures list Picture 8: Global view Picture 9: Keyboard Picture 10: Main menu Picture 11: Lateral view Picture 12: Utility menu. Picture 13: Parameters procedures list Picture 14: Maintenance list Picture 15: Date and time menu. Picture 16: Date and time format list. Picture 17: Screen shot âSelf-Test in progressâ Picture 18: Scale tare Picture 19: Reading scale area Picture 20: Archimede view Picture 21: Manual movement window Picture 22: Enable procedures list Picture 23: Questions view Picture 24: Kit installation procedure T/T triple Picture 25: Position primary T/T triple bag. Picture 26: Position plasma and Sag.M. T/T triple bags. Picture 27: T/T Triple bags in position. Picture 28: Break cannulas view T/T triple procedure. Picture 29: Sealing procedure T/T triple Picture 30: Viewing weights T / T triple. Picture 31: Reweigh T/T quadruple. Picture 32: T/T quadruple with weight out of normal range. Picture 33: Pause or Stop procedure T/T triple. Picture 34: Kit installation T/T quadruple procedure. Picture 35: Position primary T/T triple bag. Picture 36: Position plasma, buffy coat and Sag.M. T/T quadruple bags. Picture 37: T/T quadruple bags in position Picture 38: Break cannulas view quadruple T/T procedure Picture 39: Sealing procedure T/T quadrupla User Manual Revision 1.05 103 13 14 14 15 15 16 16 17 18 19 20 24 24 24 25 25 27 30 30 30 31 32 33 35 35 35 36 36 37 37 37 38 38 40 40 40 41 41 42 Page 7 of 105 CONTENTS Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture 40: Viewing weights T / T quadruple. 41: T/T quadruple with weight out of normal range. 42: T/T quadruple with weight out of normal range 43: Pause or Stop procedure T/T quadruple 44: Kit installation T/B triple procedure. 45: Position primary T/B triple bag. 46: Position plasma, buffy coat and Sag.M. T/T triple bags. 47: T/B triple bags in position. 48: Break cannulas view T/B triple procedure. 49: Sealing procedure T/B tripe 50: Viewing weights T / B triple. 51: Reweigh T/B triple 52: T/B triple with weight out of normal range. 53: Pause or Stop procedure T/B triple 54: Kit installation T/B quadruple procedure 55: Position primary T/B quadrupla bag. 56: Position plasma, buffy coat and Sag.M. T/B quadruple bags. 57: T/B quadruple bags in position. 58: Break cannulas view T/B quadruple procedure. 59: Sealing Procedure T/B quadruple 60: Viewing weight T/B quadruple 61: Reweight T/B quadruple 62: T/B quadruple with weight out of normal range. 63: Pause or Stop procedure T/B quadruple. 64: Kit installation procedure PRP to PPP+PLT 65: Position primary bag procedure PRP to PPP + PRP 66: Position PLT bag procedure PRP to PPP + PRP. 67: PRP to PPP + PRP bags in position. 68: Break cannulas view procedure PRP to PPP + PRP 69: Sealing procedure PRP to PPP + PRP 70: Viewing weight PRP to PPP + PRP. 71: Reweight procedure PRP to PPP + PRP. 72: Procedure PRP to PPP + PRP with weight out of normal range.. 73: Pause or Stop procedure PRP to PPP + PRP. 74: Kit installation procedure PLT with filter 75: Position primary bag separation PLT with filter. 76: Position PLT bag separation PLT with filter. 77: Bag PLT with filter in position. 78: Break cannulas view procedure PLT with filter. 79: Sealing procedure PLT with filter. 80: Viewing weight PLT with filter. 81: Reweight procedure PLT with filter. 82: Procedure PLT with filter with weight out of normal range. 83: Pause or Stop procedure PLT with filter. 84: Kit installation procedure erythrocytes washing. 85: Position primary bag erythrocytes washing. 86: Position erythrocytes washing bag. 87: Erythrocytes washing bag in position. 88: Break cannulas view erythrocytes washing procedure 89: Sealing erythrocytes washing procedure. 90: Viewing weight erythrocytes washing . 91: Reweight procedure erythrocytes washing. 92: Pause or Stop in procedure erythrocytes washing . 93: Kit installation procedure umbilical cord 94: Position primary bag umbilical cord procedure. 95: Position plasma, RBC bag of umbilical cord procedure. 96: Erythrocytes umbilical cord in position. 97: Break cannulas view umbilical cord procedure. 98: Sealing umbilical cord procedure. Page 8 of 105 42 42 43 43 45 45 45 46 46 47 47 47 48 48 50 50 50 51 51 52 52 53 53 53 55 55 55 56 56 57 57 57 58 58 60 60 60 61 61 62 62 62 63 63 65 65 65 66 66 67 67 67 68 70 70 70 71 71 72 User Manual Revision 1.05 CONTENTS Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture Picture 99: Viewing weight umbilical cord procedure 100: Reweight umbilical cord procedure. 101: Pause or Stop procedure umbilical cord. 102: Kit installation aliquot separation procedure. 103: Position primary bag aliquot separation procedure. 104: Position aliquot separation procedure. bag. 105: Aliquot separation procedure bag in position. 106: Break cannulas view aliquot separation procedure. 107: Viewing weight aliquot separation procedure. 108: Reweight aliquot separation procedure. 109: Saldatura procedura separazione in aliquote 110: Pause or Stop aliquot separation. 111: Kit installation procedure T & T with predefined HCT. 112: Position primary bag T & T with predefined HCT procedure. 113: Position plasma bag T & T with predefined HCT procedure. 114: T & T with predefined HCT procedure bag in position. 115: Break cannulas view procedure T & T with predefined HCT. 116: Sealing procedure RCC T & T with predefined HCT. 117: Viewing RCC T & T with predefined HCT procedure. 118: Reweight T & T with predefined HCT procedure. 119: RCC T & T with predefined HCT procedure with weight out of normal range. 120: Pause or Stop procedure RCC T & T with predefined HCT. 121: Calibration menu. 122: Calibration, weight sample setting. 123: First step calibration. 124: Second step calibration. 125: Calibrazione, visualizzazione fattori di correzione. 126: WLAN connection 127: Communication request from Archimede 128: Communication request from ArchimedeLINK 129: Maintenance view User Manual Revision 1.05 72 72 73 75 75 75 76 76 77 77 77 78 80 80 80 81 81 82 82 82 83 83 85 85 85 85 86 87 88 89 99 Page 9 of 105 CONTENTS Page 10 of 105 User Manual Revision 1.05 INTRODUCTION INTRODUCTION The present user manual describes functions, operation and using instructions of Archimede. Please read the present document before using the instrument, and keep it to hand for consultation in order to ensure proper system operation. Archimede is an automatic extractor of emocomponents from whole blood. It allows to separate Erythrocytes, Buffy Coat, and Platelets from rich and poor plasma and platelet concentrate. Both Standard and Top & Bottom bags can be used and, thanks to the high automatization one single operator can use several units at the same time. The laboratory productivity is therefore increased maintaining a high and standardized separation quality. The separation procedure is continuously checked by a dedicated microcontroller. In case of alarm or if the preset parameter values are reached, the procedure is stopped. 1.1 Intended Use Archimede should be used by Qualified Personnel only. It has been designed for the separation of emocomponents contained in hermetically sealed bags (bags containing whole blood and/or blood derivatives) consistent with the International Standard ISO 3826 and with the 93/42 MDD regulation. For optimum operation Archimede should be placed on a solid and stable surface, preferably away from direct heat sources. 1.2 Key features ⢠⢠⢠⢠⢠⢠⢠⢠⢠⢠⢠⢠⢠⢠⢠⢠⢠⢠⢠⢠⢠⢠User-friendly interface. Graphic display of bags weight, force, and operation stages. Automatic delivery of Sag. M. through press. Variable speed separation movement, controlled by a stepper motor. Array of ten optical sensors for Buffy Coat level check. Optical detector of RBC, with electronic control of cover closure. Electronic control of the distance between plate and profile plate. Electronic control of the applied force with motor stop in case the safety limit is exceeded. Three scales with 2 Kg full-scale and 1 g resolution. Six clamps: four sealing-head clamps, one flow control clamp, one normal clamp. Mechanical buffy-coat separation system. Detection system of proper tubes positioning in each clamp. Can store up to 18 separation procedures, with approx. 40 parameters each. Self-tare and auto-calibration of the various measuring systems via software. Regulation trimmers have therefore been eliminated. The auto-calibration functions are managed directly by ArchimedeLINK. Can be used as a sealer and as a scale . Self-diagnosis program to make the solution of technical problems easier. Bi-directional data transmission via WLAN. PS2 port for barcode reader. Software update directly through PC. Built-in clock and calendar for traceability of the ongoing procedure. Optional RFID reader. Optional 2D bar code reader able to read multiple bar codes in one shot. User Manual Revision 1.05 Page 11 of 105 INTRODUCTION Page 12 of 105 User Manual Revision 1.05 INSTALLATION INSTALLATION Archimede is a simple use highly versatile instrument allowing great automation. It is supplied with preinstalled standard procedures that can be implemented and modified through ArchimedeLINK. Upper bag holder Barcode Side scale holders Picture 1: Parts included in the packing. Profile plate Support bar WLAN antenna Magnetic filter holder Power cable 2.1 Unpacking Archimede Remove Archimede from its packing. Take care not to crash the load cells. Check that no part is damaged. ⢠⢠⢠⢠⢠⢠⢠⢠Archimede is supplied with: Upper bag-holder plate and side scale-holders. Magnetic filter-holder. Pacemakers and floppy disk must keep away at least of 10 cm. WLAN antenna. Profile plate 2, 3, 4. Support bar. Power cable. Barcode reader. 2.2 Positioning Archimede ⢠⢠⢠⢠⢠⢠⢠Environmental conditions may affect Archimede operation. The following conditions should therefore be avoided or minimized: High temperatures, elevated humidity, proximity of free flames. Direct sunlight exposure. Elevated dust accumulation. Proximity of flammable substances. Unstable and non-flat surfaces or slippy. Separation distance of 20 cm must be maintained between the WLAN antenna and human bodies 2.3 Assembling scale, filter holders and antenna. Lean the plastic plate on the upper scale holder. Screw the side scale holders paying attention to the load cells: the load cells are mechanically protected but, they should not be hit with force. Screw antenna and place it in vertical position. The filter holder is magnetic, and can be put in the most suitable position to support the filter during the procedures requiring filter use. User Manual Revision 1.05 Page 13 of 105 INSTALLATION 2.4 Switching on Archimede The power cord must be plugged into a grounded power receptacle. When using an extension cord, make sure it is properly grounded. Any rupture of the ground lead inside or outside the instrument or a loose ground connection may result in hazardous operating conditions for the operating personnel. Intentional disconnection of the grounding is not permitted. The correct value of line voltage and line fuses are indicated on the rear plate of the instrument. Check that mains power switch on rear left is in 0 position. Then plug the Barcode Reader into the socket marked with Plug the power cord and turn the main switch on. Picture 2: Archimede display If Archimede is not in Stand Alone mode but is connected with ArchimedeLINK in WLAN, before proceed with the other controls it is necessary to set WLAN parameters. This configuration is described in the service manual at the paragraph configuration WLAN. When the display lights on, instrument model and firmware software revision number should appear. After verifying and initializing all data stored, Archimede performs a self-check of all measurement systems. In case of malfunction the display shows the problem detected and the possible remedy. Picture 3: Screen shot âSelf Testâ Press Plate Area ATTENTION: DO NOT PUT YOUR HANDS IN THE FRONTAL PRESS PLATE WORKING AREA. Page 14 of 105 User Manual Revision 1.05 INSTALLATION 2.5 Instrument Setup All sensitive data are preset in a non volatile RAM. They can be modified using ArchimedeLINK. Date and time are managed by a dedicated circuit that can operate for at least 60 days even without main power. However, if Archimede does not operate in stand alone mode, date and time are automatically updated when switching the instrument on, and get synchronized to ArchimedeLINK. When using the instrument for the first time, date and time need to be checked only if the system is not integrated with ArchimedeLINK. 2.5.1 Date and Time Using direction key-buttons current date and time. Press highlight the display area indicating to enter modify mode. Picture 4: Date and time menu. Set date and time using keys , up and down key to increase or decrease value, left and right to change the digit to modify and to confirm setting. If you donât want to confirm the date and time change, press key FORMAT 12 24 dd-mm-yyyy mm-dd-yyyy yyyy-mm-dd READING 0-24 0-12 am/pm 01-04-2008 04-01-2008 2008-04-01 Picture 5: Date and time format list. Set current date and time, and confirm setting with key If you donât want to confirm the date and time change, press key User Manual Revision 1.05 Page 15 of 105 INSTALLATION 2.5.2 Procedures Setup Check This check allows to verify all procedure parameters, and should be performed by the application specialist or service engineering. Procedure parameters and their meaning are described and can be set through ArchimedeLINK. The procedure is continuously displayed to enable users (above all those working in stand alone mode) to verify its correctness. To enter key-button above the icons this menu press PARAMETER LIST. and use direction key button to select Picture 6: Utility menu. Confirm setting with key Using direction key-buttons it is possible to select the desired procedures. Picture 7: Parameters procedures list Archimedes due to its versatility enables automation combined with ease of use. Itâs setup with a minimum of standard procedures installed, implemented and modified through ArchimedeLINK with the help of a technical application. Page 16 of 105 User Manual Revision 1.05 GENERAL DESCRIPTION GENERAL DESCRIPTION Archimede consists of two parts: ⢠⢠The electronic part includes a built-in microcontroller of the latest generation. Through this microcontroller the instrument can store the procedures data, control graphic display, drives motors, scales, sensors, clamps, sealer group and RFID reader. The mechanical part includes an axial system enabling movement of plate and buffycoat separation system. Picture 8: Global view 3.1 Upper Panel The upper panel is designed to house tubes and collection bags. It includes: ⢠⢠⢠⢠⢠Upper scale, with removable plate; weight capacity 0-2000 grams with Âą 1 g resolution. Photometer for red blood cells detection. It consists of a 540 nm optical system and a couple of IR sensors for air bubbles detection. A reflection optical systems detects cover state (open/closed) and tube presence. Three sealing head clamps: âTopâ, âPlasmaâ, and âBuffy Coatâ; one normal clamp for âSag.Mâ. One proportional valve for plasma flow control. Holder for additional bag. 3.2 Front Panel The front panel is designed to hold the bag from which the emocomponents are to be extracted. It includes: ⢠⢠⢠⢠⢠⢠Mobile separation plate controlled by one stepper motor and two sensors: the first sensor detects the distance between plate and profile plate, the second sensor detects the applied force. Fix plate provided with holders where the bag in use can be hanged. Primary bag support with bars for stainless-steel cannula breaking. Optical device for detection of buffy coat level. It consists of ten IR sensors linearity placed. Clamp âBottomâ with sealing head. Sensor for detection of the type of plate in use. User Manual Revision 1.05 Page 17 of 105 GENERAL DESCRIPTION 3.2.1 Keyboard Some of the keyboard key-buttons are multifunction. Picture 9: Keyboard Allows to stop some functions and go back to the upper menu level. Direction key-buttons: allow to move inside a menu and to change the value of the selected function. Allows to confirm the change or the selection. Allows to start the separation procedure. Allows to stop the ongoing procedure or application after confirmation. Allows to start the displayed function. Page 18 of 105 User Manual Revision 1.05 GENERAL DESCRIPTION 3.2.2 Backlight Display The screen is a wide LCD 240 x 128 graphic display. It is backlit to improve reading in poorly illuminated rooms. Picture 10: Main menu Here is the meaning of the displayed functions: This menu allows to enter maintenance actions displayed. submenus to have parameters and Press to login operator by bar code reader. The instrument status is displayed in this area. Current time is displayed in this area. This menu allows to set the tare and to have front scale, upper scale and side weight displayed. Date of the last scales calibration is displayed in this area. This function allows to move back and forth the pressing plate. This function allows to open and close the selected clamp. The arrow appears when the sealing is activated. This function allows to enter the menu to select the desired procedure. The procedure can be selected manually or through BC reading of the type of bag. User Manual Revision 1.05 Page 19 of 105 GENERAL DESCRIPTION 3.3 Rear Panel The rear side includes the main power socket and two connectors that enable data exchange with the barcode reader and with a host computer. Power supply group including: power socket, On-Off switch, and fuse holder. Antenna for WLAN connection to ArchimedeLINK. PS2 connector. Allows connection to barcode reader. Yellow led it is:. ⢠Lit; when Archimede is not connected in WLAN. ⢠Flash: when Archimede search WLAN. ⢠Off: when Archimede is connected in WLAN. Green led. It is not activated. Designed by manufacturer for exclusive connection to the instrument according to the prescriptions contained in the specific documentation of that instrument and to EN60950 Regulation. 3.4 Side Panel Picture 11: Lateral view The right-side panel includes the support for lateral scale and the magnetic and removable filter support. The filter support is to be used if required by the selected procedure. Page 20 of 105 User Manual Revision 1.05 GENERAL DESCRIPTION 3.5 Meaning of Procedure Parameters During the separation procedure Archimede operation is affected by several parameters. Some of these parameters are fix, that is, preset by the management program. Other parameters are variable, that is, settable by an application engineer through an external PC. All variable parameters are factory preset and saved in a non-volatile memory with elevated retention capacity. Fix parameters are used to monitor all the events with top priority alarm, i.e.: time necessary to enable all actuators very long, Sag. M dispensing time very long, etc. In order to obtain a better management, procedure parameters are divided into group, defined by their meaning: General control Parameters for procedure security control activation. 21 25 38 41 43 44 45 46 TUBES CHECK: During the procedure, checks that tubes are properly inserted into the clamps enabled for the ongoing procedure. Sag.M. quantity: Sag.M. amount already inside in the bag for RBC. Main bag weight: Weight of primary bag. PLT FILTRATE FLOW ALARM : Minimum flow that should pass through the filter. Below this value an alarm of obstructed filter is activated. Profile plate number: Number of profile plate use in the procedure. Primary Bag Positioning with Blade Ready for Weighing: Enables blade coming out to move primary bag away from front panel and allow correct weighing. Scale Stability Check: Enables check of weight stability as detected by enabled scales. Check Correlation Distance Weight: Check correlation between thickness bag and emocomponent weight. Enable scale reading: Must be inhibit in Archimede light version. Initial phase Parameters for Breaking Cannulas phase. 24 CANNULAS BREAKING ENABLING: Enables the routine controlling breaking of the primary bag cannulas. CANNULAS BREAKING THRESHOLD: Force in xx.x Kg beyond which the plate stops and waits for cannulas breaking. MOTOR SPEED DURING CANNULAS BREAKING: Plate forward moving speed during cannulas breaking step. CANNULAS BREAKING HYSTERESIS: Value used to calculate the force value below which the system exits out of the cannulasbreaking routine. V = (force measured at breaking position) â (current force). MOTOR SPEED DURING FILTER PRIMING: Plate forward moving speed during filter priming. Optical sensor management Parameters for manage optical sensors of Archimede (IR and RBC). User Manual Revision 1.05 Page 21 of 105 GENERAL DESCRIPTION NUMBER OF IR SENSOR USED TO ENABLE HB SENSOR: Number identifying the IR sensor dedicated to RBC sensor activation. RBC TARGET LEVEL: (PROCEDURE 8) Value of IR - HB sensor to intercept the level of RBC. MINIMUM OPTICAL GAP BETWEEN RBC AND PLASMA: Value minimal of difference of reading between RBC and plasma with which it comes controlled the bag before and during the procedure. 8 HB SENSOR SENSIBILITY: Sensibility HB sensor. 10 IR SENSOR ACTION THRESHOLD: Threshold value for action of IR sensors. 15 NUMBER OF IR SENSOR USED FOR CHECK BUFFY COAT LEVEL: Decimal number identifying the IR sensor buffy coat level position. HAEMATOCRIT SELECTION: (PROCEDURE 13) Allows you to set the desired level of haematocrit, based on this value system displays the number of IR LED concerned. 26 CLAMP CLOSURE DELAY TIME AFTER ERYTHROCITES LEVEL DETECTION Delay time for clamp closure after detecting erythrocites level [0-25]s. 42 Air Elimination: Allows to enable or inhibit the air elimination routine from plasma. 47 SELECTION OF IR CORRESPONDING TO UPPER AND LOWER BAG SIDE: Allows to select the calibration sensors to be used to define the systemâs optical sensitivity. For optimum operation of the optical system, always select sensors within lower and higher reflection area of the label. If this is not possible because the label is on both sides, select so that the sensors can detect both plasma and RBCs. Force management Parameters for the force regulation system during the procedure. MAXIMUM FORCE: Value of the maximum force applied during the procedure; the plate stops if the force exceeds this limit. 13 MOTOR SPEED IN AUTOLEARNING PHASE: Plate moving speed used in the first phase for the management of force . Seal management Parameters the select witch clamps will seal and how the selected clamp will seal. 11 SEALING MODE: Selection of the sealing mode. In automatic mode, the system automatically seals the bags when the procedure is over. In manual mode, bags sealing must be confirmed. 12 SEALING CLAMPS SELECTION: Selection of clamps to be used for sealing when the procedure is over. Clamps are numbered as follows: 1 Top, 2 Plasma, 4 Buffy, 8 Bottom. The value to be set in this position is the value corresponding to the sum of the clamps used: for example, if bottom and top are to be used, the value to be set is 9. 40 Clamps Number: Value allowing to select the clamps to be used in the procedure. Maximum flow of Sag. M. supplied, beyond which the dispensing force decreases. Page 22 of 105 User Manual Revision 1.05 GENERAL DESCRIPTION Emocomponent volume Parameters that define the Buffy Coat and the Sag.M. target volume. 18 RBCS NOT DETECTED FINAL DISTANCE WARNING: Final distance value beyond which the system, after confirmation, stops the procedure if RBCs have not been detected. BUFFY COAT VOLUME: Desired buffy coat volume. INSUFFICIENT DISPENSED VOLUMES FINAL DISTANCE WARNING: Final distance value beyond which the system, after confirmation, stops the procedure if the set volumes have not been dispensed. 20 SAG. M. AMOUNT: Sag. M. in [g] to be dispensed in the final step of the procedure. 22 BUFFY COAT AMOUNT WITHOUT BLADE SEPARATION: Buffy coat [g] top be dispensed before mechanical blade separation. 23 BUFFY COAT ALARM DISTANCE: Value of the distance beyond which the system, after confirmation, stops the procedure if the desired buffy coat amount has not been collected. 29 ALIQUOT WEIGHT 1: ( UPPER SCALE) Weight 1 desired for aliquot separation procedure. 14 ALIQUOT 2 WEIGHT: (UPPER SCALE) Weight 2 desired for aliquot separation procedure. 30 PLASMA-PLT WEIGHT: Value of the amount of plasma-plt to be separated. 37 BUFFY COAT TOTAL WEIGHT: Total buffy coat weight. 39 ALIQUOT 3 WEIGHT: (LATERAL SCALE) Weight 3 desired for aliquot separation procedure. Secondary Emocomponent volume Parameters that define the auto recover, wash or dilution and aliquot separation target volume. 19 EXCESS PLASMA FOR FILTER: Excess plasma [g] to be collected after the system has detected the buffy coat. MANUAL DISPENSING: Enables manual platelets recovery after detecting RBCs. 32 SENSIBILITY OF FLOW VALVE: Adjust sensitivity of flow valve feedback. (Clamp 6) 34 PLASMA FOR BC DILUTION: Amount of plasma to be added to the buffy coat when its separator is enabled. 35 Delay for BUFFY COAT LINE CLEANING WITH SAG.M.: Delay for cleaning deviation of Buffy Coat line with Sag.M. 36 PLASMA AMOUNT FOR BUFFY COAT TUBE CLEANING: Amount of plasma to be dispensed by gravity in the buffy coat bag. User Manual Revision 1.05 Page 23 of 105 GENERAL DESCRIPTION 3.6 Procedure Parameters Display Archimede is equipped with a long-retention internal memory. Up to 18 procedures can be stored, with up to 40 parameters each. To display procedure parameter press button key-button above the icons and use direction key to select PARAMETER LIST. Picture 12: Utility menu. Confirm setting with key Using direction key-buttons it is possible to select the desired procedures. Picture 13: Parameters procedures list All procedures parameter values have been optimized in various testing centres. However, parameter values can be changed by the application engineer through ArchimedeLINK to improve the desired procedure. 3.7 Maintenance Display Maintenance actions can be displayed only when Archimede is connected to ArchimedeLINK. In this case, maintenance actions can be managed reporting to ArchimedeLINK any information, including operator name and date of execution. It is also possible to schedule the desired maintenance actions according to the Blood Transfusional Centre protocol. To confirm the action performed, select maintenance type using the arrow read the operator code. , confirm by pressing and Picture 14: Maintenance list 3.8 Date and Time Although the display normally shows only hours and minutes, Archimede is provided with a built-in calendar used to send to ArchimedeLINK procedure data, including date and time. Using direction key-buttons Page 24 of 105 highlight the display area indicating User Manual Revision 1.05 GENERAL DESCRIPTION current date and time. Press to enter modify mode. Picture 15: Date and time menu. Set date and time using keys , up and down key to increase or decrease value, left and right to change the digit to modify and to confirm setting. If you donât want to confirm the date and time change, press key FORMAT 12 24 dd-mm-yyyy mm-dd-yyyy yyyy-mm-dd READING 0-24 0-12 am/pm 01-03-2008 03-01-2008 2008-03-01 Picture 16: Date and time format list. Set current date and time, and confirm setting with key If you donât want to confirm the date and time change, press key If the Blood Transfusional Centre uses ArchimedeLINK, date and time are automatically updated when the instrument is switched on or at the first connection of the day. The PC date and time are the reference data. 3.9 Scales Archimede is provided with one front scale, one upper scale, and one side scale. All of them have a weighing capacity up to 2 Kg with Âą 1 g resolution. The scales are electronically calibrated using a certified standard weight as a reference. The calibration date is highlighted in the lower display area dedicated to weights. Calibration is performed using ArchimedeLINK. The procedure is usually performed by a trained engineer authorized by the manufacturer. Before using the system as a scale, it is necessary to set the tare value. Move the cursor using the arrows until the display shows âzeroâ in the scales area. Press to zero all values. The bag or product you have to weight can be hanged to the front scale or to the side scale, or placed on the upper scale. 3.10 Manual Control of Plate Forward Moving The plate can be manually moved forward and backward. This can be useful both if you want to press a bag manually, and if you want to check that the movement axial system is working correctly. User Manual Revision 1.05 Page 25 of 105 GENERAL DESCRIPTION CAUTION: DO NOT PUT YOUR HANDS IN THE PLATE WORKING AREA. To enter this mode, use the arrows to highlight the icon , and then press .. Now move the arrows up and down to move the plate in the desired direction. The forward moving is always controlled by the maximum applied force, while the backward moving is ; to controlled by open plate limit switch. To stop the plate and keep the position press exit and put the plate in standby position press This mode also allows to enable clamps by pressing ; if the clamp is closed and the tube is in position it is possible to seal by pressing Clamp number 5 of Sag. M. is not provided with sealing head, therefore cannot be used as a sealer. 3.11 Clamps Manual Control All mounted clamps can be manually controlled with the exception of the flow clamp. This can be useful during the use of manual plate movement and to seal tubes to the bags. The clamps positions change from open to closed and vice versa by pressing the key-button . If the highlighted clamp has to be used as a sealer, insert the tube to be under the icon sealed in the clamp and press . The sealing cycle is inhibited in case the electronic protection implemented in the CSU detects the presence of moisture on the sealing clamp. Clamp 5 of Sag. M. is not provided with sealing head and therefore cannot be used as a sealer. Page 26 of 105 User Manual Revision 1.05 USING ARCHIMEDE USING ARCHIMEDE Using Archimede in separation mode is simple thanks to the built-in microcontroller. The microcontroller constantly checks the following parameters: buffy coat level, RBCs presence, weights, distance between plate and profile plate, separation speed, separation force, maximum settable force, correct program performance. If connected to ArchimedeLINK, Archimede sends all sensor and procedure data, including those acquired by the barcode reader. In stand alone mode data are store into a FIFO memory and should be sent automatically to ArchimedeLINK on next connection. 4.1 Switching on The switch on procedure includes a complete self-check of the system. Before switching Archimede on it is therefore necessary to remove any bag and check that the bags holders are free and correctly placed. After plugging the power cable, turn on the main switch on instrument rear. The display should be back lighted and show âARCHIMEDEâ. If not, check that the power cable is well plugged and that the power socket in use is powered. If the display does not light up, please see Troubleshooting section. 4.2 System Self-check Every time it is turned on, Archimede performs a self-check to verify proper system operation. Picture 17: Screen shot âSelf-Test in progressâ The actions performed following a negative check depend on the connection mode Stand Alone or ArchimedeLINK. E2prom Memory Check of data integrity concerning calibration and procedure parameters. If data are incorrect, the system, after confirmation, will initialize them and restore the factory set values. Procedure data are restore to factory set values, while calibration data will require a new calibration. User Manual Revision 1.05 Page 27 of 105 USING ARCHIMEDE Clock Date and time check. If date and time values are incompatible with the format, the system, after confirmation, will initialize them at 00:00:00 01/03/08. Synchronization with data and time of ArchimedeLINK Server. Scales Tare check of all scales. If the tare values are not within the preset limits, an error alarm will be sent and displayed. If the problem persists, please see the Troubleshooting section. Same as in stand alone mode. Plate motor Check of motor movement and limit switch. If limit switches are not enabled within the preset travel limits, an error alarm will be sent and displayed. If the problem persists, please see the Troubleshooting section. Same as stand alone mode. Buffy-coat separation motor Check of motor movement and limit switch. If limit switches are not activated within the preset travel limits, an error alarm will be sent and displayed. If the problem persists, please see the Troubleshooting section. Same as stand alone mode. IR sensors IR sensors check and self-calibration. If IR sensors have an elevated dark current or a low sensibility, an error alarm will be sent and displayed. If the problem persists, please see the Troubleshooting section. Same as stand alone mode. Force sensor Force sensor check. If the force detected by the sensor is over the preset limits, an error alarm will be sent and displayed. If the problem persists, please see the Troubleshooting section. Same as stand alone mode. HB sensor HB sensor check and self-calibration. If the HB sensor has an elevated dark current or a low sensibility, an error alarm will be sent and displayed. If the problem persists, please see the Troubleshooting section. Same as stand alone mode. Page 28 of 105 User Manual Revision 1.05 USING ARCHIMEDE CSU Check of sealing unit and tubes detector. If the CSU state is not âreadyâ, and if there are moisture or tubes within clamps, an error alarm will be sent and displayed. If the problem persists, please see the Troubleshooting section. Same as stand alone mode Flow control clamp Actuator movement check. If the limit switch is not activated within the preset travel limits, an error alarm will be sent and displayed. If the problem persists, please see the Troubleshooting section. Same as stand alone mode. User Manual Revision 1.05 Page 29 of 105 USING ARCHIMEDE 4.3 Use as a scale Archimede can be used as a weighing system thanks to its three load cells. The maximum measurable weight is 2 Kg with 1 g resolution. Before using the system as a scale, it is necessary to calculate the tare. Move the cursor using until the word âzeroâ is displayed in the scales area of the screen and press the arrows to zero the values. Picture 18: Scale tare Now use the arrows to move the cursor to another option; this will avoid performing another tare by pressing key-button unintentionally Take the product you wish to weigh and hang it to the front or side scale, or put it on the upper scale. Weights are displayed in the following order: Front scale Upper scale Side scale Picture 19: Reading scale area 4.4 Use as a sealing unit Archimede can be used as a sealing unit thanks to its four built-in sealing heads. Press key-button below the sealing head that you wish to use or highlight the sealing head using the arrows Location of the sealing heads is as follows: [5] NON-SEALING HEAD [4] SEALING HEAD [3] SEALING HEAD [2] SEALING HEAD [1] SEALING HEAD Picture 20: Archimede view Page 30 of 105 User Manual Revision 1.05 USING ARCHIMEDE To perform sealing with the selected sealing head, press key-button. If you donât want to seal but, you want to open or close the selected clamp, press shown on left side of the clamp by the symbol . Sealing operation will be In case any error occurs, this will be displayed in the notice window of the screen: ⢠Clean sealing head: the CSU has detected some moisture; it is necessary to clean sealing head and tube and check for leakages. ⢠Insert tube: the tube sensor has detected that the tube is missing or incorrectly inserted in the sealing head clamp. ⢠CSU busy: the CSU is busy with a sealing cycle; retry after a few seconds. 4.5 Use as manual separator Archimede can also be used as a manually controlled separator. In this mode the enabled checks are the following: ⢠Position sensor determining the plate standby position. ⢠Force sensor determining plate stop if the applied force exceeds the set value. When the applied force decreases below the value calculated according to the hysteresis, the plate starts again. The values set for force and hysteresis are those set during the first active procedure. ATTENTION: THE FORCE SENSOR IS ENABLED ONLY WHEN THE PLATE MOVES TOWARDS THE INSTRUMENT BODY. CAUTION: DO NOT PUT YOUR HANDS IN THE PLATE WORKING AREA WHEN THE PLATE IS MOVING. to highlight the icon and then press . Now To enter this mode, use the arrows press the arrows up or down to move the plate in the desired direction, and press the arrows left or right to change the applied force with fix increments of 5 units. ; to exit and move the plate to To stop the plate and maintain the position press standby position press In this mode you can also enable the clamps by pressing key-button, and seal by pressing key-button. Clamp 5 of Sag. M. is not provided with sealing head and cannot be used as a sealer. Picture 21: Manual movement window User Manual Revision 1.05 Page 31 of 105 USING ARCHIMEDE 4.6 Separation Procedure Archimede can store up to 18 procedures. The operator can perform a manual selection or an automatic selection if the system is connected to ArchimedeLINK. ⢠Manual mode: To speed up procedures selection, the system can be configured to show only the procedures enabled. In this way, only the procedures most frequently used in the blood transfusional center will be displayed. Using the arrows procedure. highlight the procedure you intend to use, then press to start the Picture 22: Enable procedures list ⢠Automatic mode: Using ArchimedeLINK it is possible to associate a bag type to a procedure type. In this way, from the main menu you will only have to read the bag type barcode and ArchimedeLINK will transmit to Archimede what type of procedure it has to run. The separation procedures presently available are: PRIMARY 10 11 13 T & T triple PPP or PRP + RCC. T & T quadruple PPP or PRP BC + RCC. Top & Bottom triple PPP+BC+RCC. Top & Bottom quadruple PPP+BC+RCC. [a] Cord separation. [b] Aliquot separation. [d] Procedure Top & Top RBC with PPP + PPP. SECONDARY # 5 PPP + PLT. # 7 PLT + residual BC with filter. # 8 Erythrocytes washing separation. Page 32 of 105 User Manual Revision 1.05 USING ARCHIMEDE 4.6.1 Questions This mode (not available in stand alone mode) allows complete procedures traceability. With ArchimedeLINK it is possible to define a series of questions to be asked soon after choosing the procedure to be used. The replies will be checked according to various criteria: length, barcode type, character type, authorized operators IDs, donors IDs, bag lot validation. Picture 23: Questions view To reply to the question indicated by the arrow, read the barcode of the item concerned. If you key-buttons. need to read a reply again, move the arrow indicating the question using Once the system has selected the type of procedure to be used, it is no longer possible to modify the reply to donor ID and operator ID. Actually, the choice criteria of the procedure take into consideration both operatorâs privileges and status of primary and secondary separation. Example: if a bag has already been processed as primary-secondary procedure, ArchimedeLINK will not allow the separation unless an operator having the due privileges forces it to do so. To clear the series of questions and return to main menu, press When all questions have been replied to, the initial display of the selected procedure will automatically appear. User Manual Revision 1.05 Page 33 of 105 USING ARCHIMEDE 4.6.2 PROCEDURE 1 T & T triple PPP or PRP + RCC. This procedure is suitable for triple bags containing Sag. M. It allows erythrocytes separation (RCC) and platelets poor plasma (PPP). Parameters used: 11 12 13 18 19 20 25 26 40 41 42 43 44 45 46 47 During the procedure, checks that tubes are properly inserted into the clamps enabled for the ongoing procedure. Enables the routine controlling breaking of the primary bag cannulas. Force in xx.x Kg beyond which the plate stops and waits for cannulas breaking. Plate forward moving speed during cannulas breaking step. Value used to calculate the force value below which the systems exits the cannulas breaking routine. V =(force measured at breaking position) â (current force). Number identifying the IR sensor dedicated to RBC sensor enabling. Value minimal of difference of reading between RBC and plasma with which it comes controlled the bag before and during the procedure Sensibility HB sensor. Value of the maximum force applied during the procedure; the plate stops if the force exceeds this limit. Selection of the sealing mode. In automatic mode, the system automatically seals the bags when the procedure is over. In manual mode, bags sealing must be confirmed. Selection of clamps to be used for sealing when the procedure is over. Clamps are numbered as follows: 1 Top, 2 Plasma, 4 Buffy, 8 Bottom. The value to be set in this position is the value corresponding to the sum of the clamps used: for example, if bottom and top are to be used, the value to be set is 9. Plate moving speed used in the first phase for the management of force Value of the distance beyond which the system, after confirmation, stops the procedure if no RBCs have been detected. Excess plasma [g] to be collected after the system has detected the buffy coat. Sag. M. amount [g] to be dispensed in the final step of procedure. Tara sacca primaria. Valore utilizzato per calcolare la quantitĂ di prodotto rimasto nella sacca primaria. [peso attuale-tara] Threshold value used to detect air bubbles during procedures requiring its elimination. Value allowing to select the clamps to be used in the procedure. Number of the profile plate to be used with the ongoing procedure. Enables the air elimination routine. Primary bag positioning with blade ready for weighing. Scale stability check. Check Correlation Distance Weight. Enable scale reading. IR corresponding to higher and lower bag edge. Page 34 of 105 User Manual Revision 1.05 USING ARCHIMEDE Position bags and tubes according to the below sequence. Be sure to avoid tensions and folds that might cause flow obstruction or weighing errors. Scale 2 Clamp 3 RBC Sensor Sag. M. bag Primary bag Scale 1 Picture 24: Kit installation procedure T/T triple NOTE: Tubes in the various kits have different lengths. To simplify kits management, the firmware allows to configure which valves you wish to enable. Picture 25: Position primary T/T triple bag. Hang the primary bag to the bag holders on the front panel. The label containing bag data should always be turned outside. After detecting the primary bag, the plate will move backword to make positioning of Sag.M. bag easier, and the display will show the bag icon. Picture 26: Position plasma and Sag.M. T/T triple bags. Hang the Sag. M. bag to the bag holders on the fix plate. Insert the Sag. M. tube firmly into clamp 5. Open the cover of HB sensor and insert the tube coming from the primary bag into the reading area. Close the cover. Insert the tube coming from the RBC sensor firmly into clamp 3. Position the plasma bag on upper scale. User Manual Revision 1.05 Page 35 of 105 USING ARCHIMEDE Picture 27: T/T Triple bags in position. Archimede checks correct tubes positioning inside proper clamps by means of its optical sensors. The tube is correctly inserted when the clamp number is replaced by the icon Press key-button to start the procedure. If the primary bag expected weight check has been enabled through ArchimedeLINK and the detected weight does not fall within the set limits, a warning will be displayed showing both limits and current weight. After verifying the cause of the problem, confirm weight with or to leave the procedure. Furthermore, if the tube presence check is enabled the press display will show the clamp numbers where tubes are not correctly inserted and the procedure will not start until all tubes are correctly inserted into the enabled clamps. Now wait for the plate to get close to the bag. The plate will exert a force corresponding to the value set in the procedure parameters. Parameters of the ongoing phase: #13: #18: #8: #19: #20: Plate forward moving speed Action distance RBC action threshold Excess plasma for filter Sag. M. amount Picture 28: Break cannulas view T/T triple procedure. Break the cannules by forcing on their side upper part, and wait a few seconds for positive pressure release. After detecting pressure decrease, Archimede automatically starts the separation cycle. If pressure does not decrease below the set value, due to tube obstruction or keybutton. fluid clogging, it is anyway possible to force the cycle start by pressing During the procedure, possible comments can be read on the external part of the fix front plate. The graphic interface will now show the current operating phase number, and the weight value of plasma collected. Archimede will check the erythrocytes level in the primary bag. When this level reaches the selected IR sensor, the display will show it in the area of the RBC-pressing plate. The photometer detecting the presence of erythrocytes will now check, in real time, the plasma flow. When the erythrocytes amount exceeds the value set in procedure parameters, the photometry will display âRBCâ on the sensor cover icon and, if dispensation of excess plasma is not provided, the separation process will stop and the plate will move backwards to allow Sag. M. dispensing. ATTENTION: THE FORCE SENSOR IS ENABLED ONLY WHEN THE PLATE MOVES TOWARDS THE INSTRUMENT BODY. CAUTION: DO NOT PUT YOUR HANDS IN THE PLATE WORKING AREA WHEN THE PLATE IS MOVING. If air elimination is enabled, the system will send the air contained in the primary bag into the Sag.M. bag both at the initial and final stage. Page 36 of 105 User Manual Revision 1.05 USING ARCHIMEDE The sealing cycle depends on the value set in the procedure parameters; Automatic sealing: sealing cycle of the selected clamps is performed automatically. Manual sealing: press keybutton to seal the enabled lines, or press continue, after confirming, without sealing. to Picture 29: Sealing procedure T/T triple Archimede will automatically send to ArchimedeLINK all events and data of the procedure performed. At the end of the procedure the display will show the detected weights. If they are not the expected ones, because tubes are not correctly placed and distort scalesâ readings, the emocomponents can be weighed again after correcting tubesâ position and the new weights can be sent to ArchimedeLINK again. Correct weights: press keybutton to continue with the same type of separation or press to go back to the page listing the procedures. Picture 30: Viewing weights T / T triple. Incorrect weights: press one of the keybuttons to weigh emocomponents again. To accept the new values and send them to ArchimedeLINK press Picture 31: Reweigh T/T quadruple. With ArchimedeLINK the normal limits check can be activated. If it is enabled and the detected weights do not fall within the set limits, the display will show the emocomponentsâ detected weights and the allowed limits. Press any key to continue. User Manual Revision 1.05 Page 37 of 105 USING ARCHIMEDE Picture 32: T/T quadruple with weight out of normal range. Now remove tubes and bags and press type or press to continue with another separations of the same to exit. If you need to interrupt the procedure either momentarily or definitively, press keybutton. Picture 33: Pause or Stop procedure T/T triple. Stop: press ArchimedeLINK. Pause: press Page 38 of 105 or or . Archimede will display the sealing page and send data to to continue the procedure. User Manual Revision 1.05 USING ARCHIMEDE 4.6.3 PROCEDURE 2 T & T quadruple PPP or PRP BC + RCC. This procedure is suitable for quadruple bags containing Sag. M. It allows to separate erythrocytes (RCC), platelets poor plasma (PPP) and buffy coat. Parameters used: 11 12 13 16 18 19 20 22 23 25 34 35 36 40 41 42 43 44 45 46 47 During the procedure, checks that tubes are properly inserted into the clamps enabled for the ongoing procedure. Enables the routine controlling breaking of the primary bag cannulas. Force in xx.x Kg beyond which the plate stops and waits for cannulas breaking. Plate forward moving speed during cannulas breaking step. Value used to calculate the force value below which the systems exits the cannulas breaking routine. V =(force measured at breaking position) â (current force). Number identifying the IR sensor dedicated to RBC sensor enabling. Value minimal of difference of reading between RBC and plasma with which it comes controlled the bag before and during the procedure Sensibility HB sensor. Value of the maximum force applied during the procedure; the plate stops if the force exceeds this limit. Selection of the sealing mode. In automatic mode, the system automatically seals the bags when the procedure is over. In manual mode, bags sealing must be confirmed. Selection of clamps to be used for sealing when the procedure is over. Clamps are numbered as follows: 1 Top, 2 Plasma, 4 Buffy, 8 Bottom. The value to be set in this position is the value corresponding to the sum of the clamps used: for example, if bottom and top are to be used, the value to be set is 9. Plate moving speed used in the first phase for the management of force. Plasma to dilute Buffy Coat. Value of the distance beyond which the system, after confirmation, stops the procedure if no RBCs have been detected. Excess plasma [g] to be collected after the system has detected the buffy coat. Sag. M. amount [g] to be dispensed in the final step of procedure. Buffy coat amount [g] to be dispensed before mechanical separation. Value of the distance beyond which the system, after confirmation, stops the procedure if the desired buffy coat amount has not been collected. Tare of the primary bag. This value is used to calculate the product amount left in the primary bag. [current weight - tare] Amount of plasma to be dispensed in the buffy coat bag. Delay for cleaning deviation of Buffy Coat line with Sag.M. Amount of plasma to be dispensed by gravity in the buffy coat bag. Value allowing to select the clamps to be used in the procedure. Number of the profile plate to be used with the ongoing procedure. Enabling of the air elimination routine. Primary bag positioning with blade ready for weighing. Scale stability check. Check Correlation Distance Weight. Enable scale reading. IR corresponding to upper and lower bag edges. User Manual Revision 1.05 Page 39 of 105 USING ARCHIMEDE Position bags and tubes according to the below sequence. Be sure to avoid tensions and folds that might cause flow obstruction or weighing errors. Scale 2 Clamp 3 Clamp 2 Scale 3 Clamp 5 Clamp 1 Sag. M. bag Primari bag Scale 1 Picture 34: Kit installation T/T quadruple procedure. NOTE: Tubes in the various kits have different lengths. To simplify kits management, the firmware allows to configure which valves you wish to enable. Picture 35: Position primary T/T triple bag. Hang the primary bag to the bag holders on the front panel. The label containing bag data should always be turned outside. After detecting the primary bag, the plate will move backword to make positioning of Sag.M. bag easier, and the display will show the bag icon. Picture 36: Position plasma, buffy coat and Sag.M. T/T quadruple bags. Hang the Sag. M. bag to the bag holders on the fix plate. Insert the Sag. M. tube firmly into clamp 5. Open cover of HB sensor and insert the tube coming from the primary bag into the reading area. Close the cover. Insert the tube coming from the HB sensor firmly into clamp 1. Insert buffy coat tube into clamp 3. Insert the plasma tube into clamp 2. Page 40 of 105 User Manual Revision 1.05 USING ARCHIMEDE Position the plasma bag on upper scale. Position the buffy coat bag on lateral scale. Picture 37: T/T quadruple bags in position Archimede checks correct tubes positioning inside proper clamps by mens of its optical sensors. The tube is correctly inserted when the clamp number is replaced by the icon Press key-button to start the procedure. If the primary bag expected weight check has been enabled through ArchimedeLINK and the detected weight does not fall within the set limits, a warning will be displayed showing both or limits and current weight. After verifying the cause of the problem, confirm weight with to leave the procedure. Furthermore, if the tube presence check is enabled the press display will show the clamp numbers where tubes are not correctly inserted and the procedure will not start until all tubes are correctly inserted into the enabled clapms Now wait for the plate to get close to the bag. The plate will exert a force corresponding to the value set in the procedure parameters. Parameters of the ongoing phase: #8: #22 #19: RBC action threshold Buffy coat amount Excess plasma for filter Picture 38: Break cannulas view quadruple T/T procedure Break the cannulas by forcing on their side upper part. Wait for a few seconds that positive pressure is released. After detecting pressure decrease, Archimede automatically starts the separation cycle. If pressure does not decrease below the set value, due to tube obstruction or keybutton. fluid clogging, it is anyway possible to force the cycle start by pressing During the procedure, possible comments can be read on the external part of the fix front plate. The graphic interface will now show the current operating phase number, and the weight value of plasma collected. Archimede will check the erythrocytes level in the primary bag. When this level reaches the selected IR sensor, the display will show it in the area of the RBC-pressing plate; the plasma line will be closed and the buffy coat line will be opened. When the buffy coat amount reaches the value set in the relevant procedure parameter, the system will enable the mechanical separation group and let the set plasma (PPP) amount flow to clean the line. When cleaning is over, buffy coat will be dispensed in the bag, and the plate will move back words to allow Sag. M. dispensing. ATTENTION: THE FORCE SENSOR IS ENABLED ONLY WHEN THE PLATE MOVES TOWARDS THE INSTRUMENT BODY. User Manual Revision 1.05 Page 41 of 105 USING ARCHIMEDE CAUTION: DO NOT PUT YOUR HANDS IN THE PLATE WORKING AREA WHEN THE PLATE IS MOVING. If air elimination is enabled, the system will send the air contanied in the primary bag to the Sag. M. bag both at initial and final stage. The sealing cycle depends on the value set in the procedure parameters: Automatic sealing: sealing cycle of the selected clamps is performed automatically. Manual sealing: press keybutton to seal the enabled lines, or press continue, after confirming, without sealing. to Picture 39: Sealing procedure T/T quadrupla Archimede will automatically send to ArchimedeLINK all events and data of the procedure performed. At the end of the procedure the display will show the detected weights. If they are not the expected ones, because tubes are not correctly placed and distort scalesâ readings, the emocomponents can be weighed again after correcting tubesâ position and the new weights can be sent to ArchimedeLINK again. Correct weights: press keybutton to continue with the same type of separation or press to go back to the page listing the procedures. Picture 40: Viewing weights T / T quadruple. Incorrect weights: press one of the keybuttons to weigh emocomponents again. To accept the new values and send them to ArchimedeLINK press Picture 41: T/T quadruple with weight out of normal range. Page 42 of 105 User Manual Revision 1.05 USING ARCHIMEDE With ArchimedeLINK the normal limits check can be activated. If it is enabled and the detected weights do not fall within the set limits, the display will show the emocomponentsâ detected weights and the allowed limits. Press any key to continue. Picture 42: T/T quadruple with weight out of normal range Now remove tubes and bags and press type or press to continue with another separation of the same to exit. If you need to interrupt the procedure either momentarily or definitively, press keybutton. Picture 43: Pause or Stop procedure T/T quadruple Stop: press ArchimedeLINK. Pause: press or or User Manual Revision 1.05 . Archimede will display the sealing page and send data to to continue the procedure. Page 43 of 105 USING ARCHIMEDE 4.6.4 PROCEDURE 3 Top & Bottom triple PPP+BC+RCC. This procedure is indicated for triple top & bottom bags to obtain buffy coat (BC), erythrocytes (RCC) and plasma (PRP). Parameters used: 11 12 13 15 18 20 21 25 32 36 40 41 42 43 44 45 46 47 During the procedure, checks that tubes are properly inserted into the clamps enabled for the ongoing procedure. Enables the routine controlling breaking of the primary bag cannulas. Force in xx.x Kg beyond which the plate stops and waits for cannulas breaking. Plate forward moving speed during cannulas breaking step. Value used to calculate the force value below which the systems exits the cannulas breaking routine. V =(force measured at breaking position) â (current force). Value minimal of difference of reading between RBC and plasma with which it comes controlled the bag before and during the procedure Sensibility HB sensor. Value of the maximum force applied during the procedure; the plate stops if the force exceeds this limit. Selection of the sealing mode. In automatic mode, the system automatically seals the bags when the procedure is over. In manual mode, bags sealing must be confirmed. Selection of clamps to be used for sealing when the procedure is over. Clamps are numbered as follows: 1 Top, 2 Plasma, 4 Buffy, 8 Bottom. The value to be set in this position is the value corresponding to the sum of the clamps used: for example, if bottom and top are to be used, the value to be set is 9. Plate moving speed used in the first phase for the management of force Number identifying the IR sensor dedicated to buffy coat level. Buffy coat target value. Sag. M. amount [g] to be dispensed in the final step of the procedure. Sag.M. amount already present in RBC destination bag. Tare of the primary bag. This value is used to calculate the product amount left in the primary bag. [current weight - tare]. Sensibility flow valve. (Clamp 6) Plasma amount to be dispensed in the buffy coat bag. Value allowing to select the clamps to be used in the procedure. Number of the profile plate to be used with the ongoing procedure. Enables the air elimination routine. Primary bag positioning with blade ready for weighing. Scale stability check. Check Correlation Distance Weight. Enable scale reading. IR corresponding to upper and lower bag edges. Page 44 of 105 User Manual Revision 1.05 USING ARCHIMEDE Position bags and tubes according to the below sequence. Be sure to avoid tensions and folds that might cause flow obstruction or weighing errors. Scale 2 Clamp 3 Scale 3 Clamp 6 HB sensor Sag. M. bag Clamp 4 Primary bag Scale 1 Picture 44: Kit installation T/B triple procedure. NOTE: Tubes in the various kits have different lengths. To simplify kits management, the firmware allows to configure which valves you wish to enable. Picture 45: Position primary T/B triple bag. Hang the primary bag to the bag holders on the front panel. The label containing bag data should always be turned outside. After detecting the primary bag, the plate will move backword to make positioning of Sag.M. bag easier, and the display will show the bag icon. Picture 46: Position plasma, buffy coat and Sag.M. T/T triple bags. If required, hang the Sag. M. bag to the bag holders on the fix plate and insert the Sag. M. tube into clamp 5. Open cover of HB sensor and insert the tube coming from the primary bag into the reading area. Close the cover. Insert the plasma tube firmly into the flow-valve. Insert the tube coming from the flow-valve firmly into clamp 3. Insert RBC tube into clamp 4. Position the plasma bag on upper scale. User Manual Revision 1.05 Page 45 of 105 USING ARCHIMEDE Position the RBC bag on lateral scale. Picture 47: T/B triple bags in position. Archimede checks correct tubes positioning inside proper clamps by mens of its optical sensors. The tube is correctly inserted when the clamp number is replaced by the icon Press key-button to start the procedure. If the primary bag expected weight check has been enabled through ArchimedeLINK and the detected weight does not fall within the set limits, a warning will be displayed showing both or limits and current weight. After verifying the cause of the problem, confirm weight with to leave the procedure. Furthermore, if the tube presence check is enabled the press display will show the clamp numbers where tubes are not correctly inserted and the procedure will not start until all tubes are correctly inserted into the enabled clapms Now wait for the plate to get close to the bag. The plate will exert a force corresponding to the value set in the procedure parameters. Parameters of the ongoing phase: #18: B.C target #8: RBC action threshold #20: Sag. M. amount Picture 48: Break cannulas view T/B triple procedure. Brake the cannulas by forcing on the side upper part of the cannula. Wait for a few seconds that positive pressure is released. After detecting pressure decrease, Archimede automatically starts the separation cycle. If pressure does not decrease below the set value, due to tube obstruction or fluid clogging, it is anywayt possible to force the cycle start by pressing keybutton. During the procedure, possible comments can be read on the external part of the fix front plate. The graphic interface will now show the current operating phase number, and the weight value of plasma collected. Archimede will check the buffy coat level through IR sensors, flow valve and valves 3 and 4. The distance sensor will stop the separation process when the plate reaches the distance set in the procedure parameters. When this process is over, the plate will move back words to allow Sag. M. dispensing if required. ATTENTION: THE FORCE SENSOR IS ENABLED ONLY WHEN THE PLATE MOVES TOWARDS THE INSTRUMENT BODY. CAUTION: DO NOT PUT YOUR HANDS IN THE PLATE WORKING AREA WHEN THE PLATE IS MOVING. Page 46 of 105 User Manual Revision 1.05 USING ARCHIMEDE Air elimination depends on procedure parameters setting: Manual air elimination: press keybutton to open clamp 3, put plasma bag in vertical position and remove air manually by pressing on the bag. When finished, press keybutton to close clamp 3, and re-position plasma bag to detect weight. The sealing cycle depends on the value set in the procedure parameters: Automatic sealing: sealing cycle of the selected clamps is performed automatically. Manual sealing: press keybutton to seal the enabled lines, or press continue, after confirming, without sealing. to Picture 49: Sealing procedure T/B tripe Archimede will automatically send to ArchimedeLINK all events and data of the procedure performed. At the end of the procedure the display will show the detected weights. If they are not the expected ones, because tubes are not correctly placed and distort scalesâ readings, the emocomponents can be weighed again after correcting tubesâ position and the new weights can be sent to ArchimedeLINK again. Correct weights: press keybutton to continue with the same type of separation or press to go back to the page listing the procedures. Picture 50: Viewing weights T / B triple. Incorrect weights: press one of the keybuttons to weigh emocomponents again. To accept the new values and send them to ArchimedeLINK press keybutton. Picture 51: Reweigh T/B triple User Manual Revision 1.05 Page 47 of 105 USING ARCHIMEDE With ArchimedeLINK the normal limits check can be activated. If it is enabled and the detected weights do not fall within the set limits, the display will show the emocomponentsâ detected weights and the allowed limits. Press any key to continue. Picture 52: T/B triple with weight out of normal range. Now remove tubes and bags and press type or press to continue with another separation of the same to exit. If you need to interrupt the procedure either momentarily or definitively, press keybutton. Picture 53: Pause or Stop procedure T/B triple Stop: press ArchimedeLINK. Pause: press Page 48 of 105 or or . Archimede will display the sealing page and send data to to continue the procedure. User Manual Revision 1.05 USING ARCHIMEDE 4.6.5 PROCEDURE 4 Top & Bottom quadruple PPP+BC+RCC. This procedure is indicated for quadruple top & bottom bags to obtain buffy coat (BC), erythrocytes (RCC) and two plasma (PPP) one PPP for single buffy coat. Parameters used: 11 12 13 15 18 20 21 25 32 34 36 40 41 42 43 44 45 46 47 During the procedure, checks that tubes are properly inserted into the clamps enabled for the ongoing procedure. Enables the routine controlling breaking of the primary bag cannulas. Force in xx.x Kg beyond which the plate stops and waits for cannulas breaking. Plate forward moving speed during cannulas breaking step. Value used to calculate the force value below which the systems exits the cannulas breaking routine. V =(force measured at breaking position) â (current force). Value minimal of difference of reading between RBC and plasma with which it comes controlled the bag before and during the procedure Sensibility HB sensor. Value of the maximum force applied during the procedure; the plate stops if the force exceeds this limit. Selection of the sealing mode. In automatic mode, the system automatically seals the bags when the procedure is over. In manual mode, bags sealing must be confirmed. Selection of clamps to be used for sealing when the procedure is over. Clamps are numbered as follows: 1 Top, 2 Plasma, 4 Buffy, 8 Bottom. The value to be set in this position is the value corresponding to the sum of the clamps used: for example, if bottom and top are to be used, the value to be set is 9. Plate moving speed used in the first phase for the management of force. Number identifying the IR sensor dedicated to buffy coat level. Buffy coat target value. Sag. M. amount [g] to be dispensed in the final step of procedure. Sag.M. amount already present in RBC destination bag. Tare of the primary bag. This value is used to calculate the product amount left in the primary bag [current weight - tare]. Flow valve sensibility. (Clamp 6) Plasma amount to be added to second plasma bag. Plasma amount to be dispensed by gravity in the buffy coat bag. Value allowing to select the clamps to be used in the procedure. Number of the profile plate to be used with the ongoing procedure. Enables the air elimination routine. Primary bag positioning with blade ready for weighing. Scale stability check. Check Correlation Distance Weight. Enable scale reading. IR corresponding to upper and lower bag edges. User Manual Revision 1.05 Page 49 of 105 USING ARCHIMEDE Position bags and tubes according to the below sequence. Be sure to avoid tensions and folds that might cause flow obstruction or weighing errors. Scale 2 Clamp 1 Clamp 2 Scale 3 Clamp 6 HB sensor Sag. M. bag Clamp 4 Primary bag Scale 1 Picture 54: Kit installation T/B quadruple procedure NOTE: Tubes in the various kits have different lengths. To simplify kits management, the firmware allows to configure which valves you wish to enable. Picture 55: Position primary T/B quadrupla bag. Hang the primary bag to the bag holders on the front panel. The label containing bag data should always be turned outside. After detecting the primary bag, the plate will move backword to make positioning of Sag.M. bag easier, and the display will show the bag icon. Picture 56: Position plasma, buffy coat and Sag.M. T/B quadruple bags. If required, hang the Sag. M. bag to the bag holders on the fix plate and insert the Sag. M. tube into clamp 5. Open cover of HB sensor and insert the tube coming from the primary bag into the reading area. Close the cover. Insert the plasma tube firmly into the flow-valve. (clamp 6) Insert the plasma tube coming from the flow-valve firmly into clamp 3. Position the plasma bag on upper scale. Insert the secondary plasma bag tube into clamp 2. Page 50 of 105 User Manual Revision 1.05 USING ARCHIMEDE Position the secondary plasma bag on upper scale. Insert RBC tube into clamp 4. Position the RBC bag on lateral scale. Picture 57: T/B quadruple bags in position. Archimede checks correct tubes positioning inside proper clamps by mens of its optical sensors. The tube is correctly inserted when the clamp number is replaced by the icon Press key-button to start the procedure. If the primary bag expected weight check has been enabled through ArchimedeLINK and the detected weight does not fall within the set limits, a warning will be displayed showing both or limits and current weight. After verifying the cause of the problem, confirm weight with to leave the procedure. Furthermore, if the tube presence check is enabled the press display will show the clamp numbers where tubes are not correctly inserted and the procedure will not start until all tubes are correctly inserted into the enabled clapms Now wait for the plate to get close to the bag. The plate will exert a force corresponding to the value set in the procedure parameters. Parameters of the ongoing phase: #18: #8: #20: B.C. target RBC action threshold Sag. M. amount Picture 58: Break cannulas view T/B quadruple procedure. Break the cannulas by forcing on their side upper part. Wait for a few seconds that positive pressure is released. After detecting pressure decrease, Archimede automatically starts the separation cycle. If pressure does not decrease below the set value, due to tube obstruction or keybutton. fluid clogging, it is anyway possible to force the cycle start by pressing During the procedure, possible comments can be read on the external part of the fix front plate. The graphic interface will now show the current operating phase number, and the weight value of plasma collected. Archimede will check the buffy coat level through IR sensors, flow valve and valves 2, 3 and 4. The distance sensor will stop the separation process when the plate reaches the distance set in the procedure parameters. When this process is over, the plate will move back words to allow Sag. M. dispensing if required. User Manual Revision 1.05 Page 51 of 105 USING ARCHIMEDE ATTENTION: THE FORCE SENSOR IS ENABLED ONLY WHEN THE PLATE MOVES TOWARDS THE INSTRUMENT BODY. CAUTION: DO NOT PUT YOUR HANDS IN THE PLATE WORKING AREA WHEN THE PLATE IS MOVING. Air elimination depends on procedure parameters setting: keybutton to open clamp 3, put plasma bag in vertical Manual air elimination: press position and remove air manually by pressing on the bag. When finished, press keybutton to close clamp 3, and re-position plasma bag to detect weight. The sealing cycle depends on the value set in the procedure parameters: Automatic sealing: sealing cycle of the selected clamps is performed automatically. Manual sealing: press keybutton to seal the enabled lines, or press continue, after confirming, without sealing. to Picture 59: Sealing Procedure T/B quadruple Archimede will automatically send to ArchimedeLINK all events and data of the procedure performed. At the end of the procedure the display will show the detected weights. If they are not the expected ones, because tubes are not correctly placed and distort scalesâ readings, the emocomponents can be weighed again after correcting tubesâ position and the new weights can be sent to ArchimedeLINK again. Correct weights: press keybutton to continue with the same type of separation or press to go back to the page listing the procedures. Picture 60: Viewing weight T/B quadruple Incorrect weights: press one of the keybuttons to weigh emocomponents again. To accept the new values and snd them to ArchimedeLINK press Page 52 of 105 User Manual Revision 1.05 USING ARCHIMEDE Picture 61: Reweight T/B quadruple With ArchimedeLINK the normal limits check can be activated. If it is enabled and the detected weights do not fall within the set limits, the display will show the emocomponentsâ detected weights and the allowed limits. Press any key to continue. Picture 62: T/B quadruple with weight out of normal range. Now remove tubes and bags and press type or press to continue with another separation of the same to exit. If you need to interrupt the procedure either momentarily or definitively, press keybutton. Picture 63: Pause or Stop procedure T/B quadruple. Stop: press ArchimedeLINK. Pause: press or or User Manual Revision 1.05 . Archimede will display the sealing page and send data to to continue the procedure. Page 53 of 105 USING ARCHIMEDE 4.6.6 PROCEDURE 5 Separation from PRP to PPP+PLT This secondary procedure is for separate from PRP to result platelets poor plasma (PPP), and platelets concentrate. Parameters used: 11 12 13 18 25 30 40 41 42 43 44 45 46 47 During the procedure, checks that tubes are properly inserted into the clamps enabled for the ongoing procedure. Enables the routine controlling breaking of the primary bag cannulas. Force in xx.x Kg beyond which the plate stops and waits for cannulas breaking. Plate forward moving speed during cannulas breaking step. Value used to calculate the force value below which the systems exits the cannulas breaking routine. V =(force measured at breaking position) â (current force). Value of the maximum force applied during the procedure; the plate stops if the force exceeds this limit. Selection of the sealing mode. In automatic mode, the system automatically seals the bags when the procedure is over. In manual mode, bags sealing must be confirmed. Selection of clamps to be used for sealing when the procedure is over. Clamps are numbered as follows: 1 Top, 2 Plasma, 4 Buffy, 8 Bottom. The value to be set in this position is the value corresponding to the sum of the clamps used: for example, if bottom and top are to be used, the value to be set is 9. Plate moving speed used in the first phase for the management of force. Value of the final distance beyond which the procedure stops. Tare of primary bag. This value is used to calculate the product amount left in the primary bag [current weight - tare]. Plasma-plt weight. Value allowing to select the clamps to be used in the procedure Number of the profile plate to be used with the ongoing procedure. Enables the air elimination routine. Primary bag positioning with blade ready for weighing. Scale stability check. Check Correlation Distance Weight. Enable scale reading. IR coresponding to upper and lower bag edge. Page 54 of 105 User Manual Revision 1.05 USING ARCHIMEDE Position bags and tubes according to the below sequence. Be sure to avoid tensions and folds that might cause flow obstruction or weighing errors. Scale 2 Clamp 3 Primari bag Scale 1 Picture 64: Kit installation procedure PRP to PPP+PLT NOTE: Tubes in the various kits have different lengths. To simplify kits management, the firmware allows to configure which valves you wish to enable. Picture 65: Position primary bag procedure PRP to PPP + PRP Hang the primary bag to the bag holders on the front panel. The label containing bag data should always be turned outside. Picture 66: Position PLT bag procedure PRP to PPP + PRP. ⢠Open HB sensor cover and put the tube coming from primary bag inside the reading area. Close cover. Insert the plasma tube firmly into clamp 3. Position the plasma bag on upper scale. User Manual Revision 1.05 Page 55 of 105 USING ARCHIMEDE Picture 67: PRP to PPP + PRP bags in position. Archimede checks correct tubes positioning inside proper clamps by mens of its optical sensors. The tube is correctly inserted when the clamp number is replaced by the icon Press key-button to start the procedure. If the primary bag expected weight check has been enabled through ArchimedeLINK and the detected weight does not fall within the set limits, a warning will be displayed showing both or limits and current weight. After verifying the cause of the problem, confirm weight with to leave the procedure. Furthermore, if the tube presence check is enabled the press display will show the clamp numbers where tubes are not correctly inserted and the procedure will not start until all tubes are correctly inserted into the enabled clapms Now wait for the plate to get close to the bag. The plate will exert a force corresponding to the value set in the procedure parameters. Parameters of the ongoing phase: #18: Action distance between phases Picture 68: Break cannulas view procedure PRP to PPP + PRP Break the cannulas by forcing on their side upper part. Wait for a few seconds that positive pressure is released. After detecting pressure decrease, Archimede automatically starts the separation cycle. If pressure does not decrease below the set value, due to tube obstruction or keybutton. fluid clogging, it is anyway possible to force the cycle start by pressing The graphic interface will now show the current operating phase number, and the weight value of plasma collected. The operating phase depends on the distance set in the procedure parameters. Archimede will check the plate distance. The distance sensor will stop the separation process when the plate reaches the distance set in the procedure parameters, and the plate will move back words to standby position. During the procedure, possible comments can be read on the external part of the fix front plate. ATTENTION: THE FORCE SENSOR IS ENABLED ONLY WHEN THE PLATE MOVES TOWARDS THE INSTRUMENT BODY. CAUTION: DO NOT PUT YOUR HANDS IN THE PLATE WORKING AREA WHEN THE PLATE IS MOVING. Page 56 of 105 User Manual Revision 1.05 USING ARCHIMEDE The sealing cycle depends on the value set in the procedure parameters: Automatic sealing: sealing cycle of the selected clamps is performed automatically. Manual sealing: press keybutton to seal the enabled lines, or press continue, after confirming, without sealing. to Picture 69: Sealing procedure PRP to PPP + PRP Archimede will automatically send to ArchimedeLINK all events and data of the procedure performed. At the end of the procedure the display will show the detected weights. If they are not the expected ones, because tubes are not correctly placed and distort scalesâ readings, the emocomponents can be weighed again after correcting tubesâ position and the new weights can be sent to ArchimedeLINK again. Correct weights: press keybutton to continue with the same type of separation or press to go back to the page listing the procedures. Picture 70: Viewing weight PRP to PPP + PRP. Incorrect weights: press one of the keybuttons to weigh emocomponents again. To accept the new values and send them to ArchimedeLINK press Picture 71: Reweight procedure PRP to PPP + PRP. With ArchimedeLINK the normal limits check can be activated. If it is enabled and the detected weights do not fall within the set limits, the display will show the emocomponentsâ detected weights and the allowed limits. Press any key to continue. User Manual Revision 1.05 Page 57 of 105 USING ARCHIMEDE Picture 72: Procedure PRP to PPP + PRP with weight out of normal range.. Now remove tubes and bags and press type or press to continue with another separation of the same to exit. If you need to interrupt the procedure either momentarily or definitively, press keybutton. Picture 73: Pause or Stop procedure PRP to PPP + PRP. Stop: press ArchimedeLINK. Pause: press Page 58 of 105 or or . Archimede will display the sealing page and send data to to continue the procedure. User Manual Revision 1.05 USING ARCHIMEDE 4.6.7 PROCEDURE 7 Single or Pool of Buffy for PLT + residual BC with filter This procedure allows to collect platelets and filtrate. Parameters used: 10 11 12 13 18 19 24 25 38 40 41 42 43 44 45 46 47 During the procedure, checks that tubes are properly inserted into the clamps enabled for the ongoing procedure. Enables the routine controlling breaking of the primary bag cannulas. Force in xx.x Kg beyond which the plate stops and waits for cannulas breaking. Plate forward moving speed during cannulas breaking step. Value used to calculate the force value below which the systems exits the cannulas breaking routine. V =(force measured at breaking position) â (current force). Number identifying the IR sensor dedicated to RBC sensor enabling. Sensibility HB sensor. Value of the maximum force applied during the procedure; the plate stops if the force exceeds this limit. Threshold value for action of IR sensors. Selection of the sealing mode. In automatic mode, the system automatically seals the bags when the procedure is over. In manual mode, bags sealing must be confirmed. Selection of clamps to be used for sealing when the procedure is over. Clamps are numbered as follows: 1 Top, 2 Plasma, 4 Buffy, 8 Bottom. The value to be set in this position is the value corresponding to the sum of the clamps used: for example, if bottom and top are to be used, the value to be set is 9. Plate moving speed used in the first phase for the management of force. Value of the distance beyond which the system, after confirmation, stops the procedure if no RBCs have been detected. Excess plasma [g] to be dispensed after the HB sensor has detected RBCs. If manual dispensing is enabled, the system allows manual product dispensing. Motor speed during filter priming. Tare of the primary bag. This value is used to calculate the product amount left in the primary bag [current weight - tare] Minimum flow that should pass through the filter. Below this value an alarm of obstructed filter is activated. Value allowing to select the clamps to be used in the procedure. Number of the profile plate to be used with the ongoing procedure. Enables the air elimination routine. Primary bag positioning with blade ready for weighing. Scale stability check. Check Correlation Distance Weight. Enable scale reading. IR corresponding to upper and lower bag edge. User Manual Revision 1.05 Page 59 of 105 USING ARCHIMEDE Position bags and tubes according to the below sequence. Be sure to avoid tensions and folds that might cause flow obstruction or weighing errors. Scale 2 Clamp 1 HB Sensor Clamp 4 Primary bag Scale 1 Picture 74: Kit installation procedure PLT with filter NOTE: Tubes in the various kits have different lengths. To simplify kits management, the firmware allows to configure which valves you wish to enable. Picture 75: Position primary bag separation PLT with filter. Hang the primary bag to the bag holders on the front panel. The label containing bag data should always be turned outside. Picture 76: Position PLT bag separation PLT with filter. Insert the tube coming from the primary bag into clamp 4. Open cover of HB sensor and insert the tube coming from filter into the reading area. Close the cover. Insert the tube coming from the HB sensor firmly into clamp 1. Position the PLT bag on upper scale. Page 60 of 105 User Manual Revision 1.05 USING ARCHIMEDE Picture 77: Bag PLT with filter in position. Archimede checks correct tubes positioning inside proper clamps by mens of its optical sensors. The tube is correctly inserted when the clamp number is replaced by the icon Press key-button to start the procedure. If the primary bag expected weight check has been enabled through ArchimedeLINK and the detected weight does not fall within the set limits, a warning will be displayed showing both or limits and current weight. After verifying the cause of the problem, confirm weight with to leave the procedure. Furthermore, if the tube presence check is enabled the press display will show the clamp numbers where tubes are not correctly inserted and the procedure will not start until all tubes are correctly inserted into the enabled clapms Now wait for the plate to get close to the bag. The plate will exert a force corresp0onding to the value set in the procedure parameters. Parameters of the ongoing phase: #13: Plate forward moving speed #18: Action distance between phases Picture 78: Break cannulas view procedure PLT with filter. Break the cannulas by forcing on their side upper part. Wait for a few seconds that positive pressure is released. After detecting pressure decrease, Archimede automatically starts the separation cycle. If pressure does not decrease below the set value, due to tube obstruction or keybutton. fluid clogging, it is anyway possible to force the cycle start by pressing During the procedure, possible comments can be read on the external part of the fix front plate. The graphic interface will now show the current operating phase number, and the weight value of PLT collected. Archimede will check the flow and stop the plate in case of filter obstruction or RBC presence in the HB sensor. In case of filter obstruction, the operator can press and continue until the new warning, while in case of RBC presence the system will stop the collection process and move the plate back to home position. During the procedure, possible comments can be read on the external part of the fix front plate. ATTENTION: THE FORCE SENSOR IS ENABLED ONLY WHEN THE PLATE MOVES TOWARDS THE INSTRUMENT BODY. CAUTION: DO NOT PUT YOUR HANDS IN THE PLATE WORKING AREA WHEN THE PLATE IS MOVING. User Manual Revision 1.05 Page 61 of 105 USING ARCHIMEDE Air elimination depends on procedure parameters setting: Manual air elimination: press keybutton to open clamp 3, put plasma bag in vertical position and remove air manually by pressing on the bag. When finished, press keybutton to close clamp 3, and re-position plasma bag to detect weight. The sealing cycle depends on the value set in the procedure parameters: Automatic sealing: sealing cycle of the selected clamps is performed automatically. Manual sealing: press keybutton to seal the enabled lines, or press continue, after confirming, without sealing. to Picture 79: Sealing procedure PLT with filter. Archimede will automatically send to ArchimedeLINK all events and data of the procedure performed. At the end of the procedure the display will show the detected weights. If they are not the expected ones, because tubes are not correctly placed and distort scalesâ readings, the emocomponents can be weighed again after correcting tubesâ position and the new weights can be sent to ArchimedeLINK again. Correct weights: press keybutton to continue with the same type of separation or press to go back to the page listing the procedures. Picture 80: Viewing weight PLT with filter. Incorrect weight: press one of the keybuttons to weigh emocomponents again. To accept the new values and send them to ArchimedeLINK press Picture 81: Reweight procedure PLT with filter. Page 62 of 105 User Manual Revision 1.05 USING ARCHIMEDE With ArchimedeLINK the normal limits check can be activated. If it is enabled and the detected weights do not fall within the set limits, the display will show the emocomponentsâ detected weights and the allowed limits. Press any key to continue. Picture 82: Procedure PLT with filter with weight out of normal range. Now remove tubes and bags and press type or press to continue with another separation of the same to exit. If you need to interrupt the procedure either momentarily or definitively, press keybutton. Picture 83: Pause or Stop procedure PLT with filter. Stop: press ArchimedeLINK. Pause: press or or User Manual Revision 1.05 . Archimede will display the sealing page and send data to to continue the procedure. Page 63 of 105 USING ARCHIMEDE 4.6.8 PROCEDURA 8 Separation of Erythrocytes Washing This procedure allows to separate the washing fluid from erythrocytes subjected to a washing procedure. Parameters used: 11 12 13 18 40 41 43 44 45 46 47 During the procedure, checks that tubes are properly inserted into the clamps enabled for the ongoing procedure. Enables the routine controlling breaking of the primary bag cannulas. Force in xx.x Kg beyond which the plate stops and waits for cannulas breaking. Plate forward moving speed during cannulas breaking step. Value used to calculate the force value below which the systems exits the cannulas breaking routine. V =(force measured at breaking position) â (current force). Number identifying the IR sensor dedicated to RBC sensor enabling. Value minimal of difference of reading between RBC and plasma with which it comes controlled the bag before and during the procedure Sensibility HB sensor. Value of the maximum force applied during the procedure; the plate stops if the force exceeds this limit. Selection of the sealing mode. In automatic mode, the system automatically seals the bags when the procedure is over. In manual mode, bags sealing must be confirmed. Selection of clamps to be used for sealing when the procedure is over. Clamps are numbered as follows: 1 Top, 2 Plasma, 4 Buffy, 8 Bottom. The value to be set in this position is the value corresponding to the sum of the clamps used: for example, if bottom and top are to be used, the value to be set is 9. Plate moving speed used in the first phase for the management of force. Value of the distance beyond which the system, after confirmation, stops the procedure if no RBCs have been detected. Value allowing to select the clamps to be used in the procedure. Number of the profile plate to be used with the ongoing procedure. Primary bag positioning with blade ready for weighing. Scale stability check. Check Correlation Distance Weight. Enable scale reading. IR corresponding to upper and lower bag edges. Page 64 of 105 User Manual Revision 1.05 USING ARCHIMEDE Position bags and tubes according to the below sequence. Be sure to avoid tensions and folds that might cause flow obstruction or weighing errors. Scale 2 Clamp 3 HB Sensor Primari bag Scale 1 Picture 84: Kit installation procedure erythrocytes washing. NOTE: Tubes in the various kits have different lengths. To simplify kits management, the firmware allows to configure which valves you wish to enable. Picture 85: Position primary bag erythrocytes washing. Hang the primary bag to the bag holders on the front panel. The label containing bag data should always be turned outside. Picture 86: Position erythrocytes washing bag. Open cover of HB sensor and insert the tube coming from the primary bag into the reading area. Close the cover. Insert the tube coming from the HB sensor firmly into clamp 1. Position the washing fluid bag on upper scale. User Manual Revision 1.05 Page 65 of 105 USING ARCHIMEDE Picture 87: Erythrocytes washing bag in position. Archimede checks correct tubes positioning inside proper clamps by mens of its optical sensors. The tube is correctly inserted when the clamp number is replaced by the icon Press key-button to start the procedure. If the primary bag expected weight check has been enabled through ArchimedeLINK and the detected weight does not fall within the set limits, a warning will be displayed showing both or limits and current weight. After verifying the cause of the problem, confirm weight with to leave the procedure. Furthermore, if the tube presence check is enabled the press display will show the clamp numbers where tubes are not correctly inserted and the procedure will not start until all tubes are correctly inserted into the enabled clapms Now wait for the plate to get close to the bag. The plate will exert a force corresponding to the value set in the procedure Parameters of the ongoing phase: #13: Plate forward moving speed #18: Action distance between phases #8: RBC action threshold Picture 88: Break cannulas view erythrocytes washing procedure Break the cannulas by forcing on the side upper part of the cannula itself. Wait for a few seconds that positive pressure is released. After detecting pressure decrease, Archimede automatically starts the separation cycle. If pressure does not decrease below the set value, due to tube obstruction or fluid clogging, it is anyway possible to force the cycle by pressing keybutton. The graphic interface will now show the current operating phase number, and the washing solution weight collected. Archimede will check the erythrocytes level in the primary bag. When this level reaches the selected IR sensor, the display will show âRBCâ in the pressing plate area. The photometer detecting the presence of erythrocytes will now check, in real time, the washing liquid flow. When the erythrocytes amount exceeds the value set in procedure parameters, the photometry will display âRBCâ on the sensor cover icon, the relative valve will stop, and the plate will move backwards to standby position. During the procedure, possible comments can be read on the external part of the fix front plate. Page 66 of 105 User Manual Revision 1.05 USING ARCHIMEDE ATTENTION: THE FORCE SENSOR IS ENABLED ONLY WHEN THE PLATE MOVES TOWARDS THE INSTRUMENT BODY. CAUTION: DO NOT PUT YOUR HANDS IN THE PLATE WORKING AREA WHEN THE PLATE IS MOVING. The sealing cycle depends on the value set in the procedure parameters: Automatic sealing: sealing cycle of the selected clamps is performed automatically. Manual sealing: press keybutton to seal the enabled lines, or press continue, after confirming, without sealing. to Picture 89: Sealing erythrocytes washing procedure. Archimede will automatically send to ArchimedeLINK all events and data of the procedure performed. At the end of the procedure the display will show the detected weights. If they are not the expected ones, because tubes are not correctly placed and distort scalesâ readings, the emocomponents can be weighed again after correcting tubesâ position and the new weights can be sent to ArchimedeLINK again. Correct weights: press keybutton to continue with the same type of separation or press to go back to the page listing the procedures. Picture 90: Viewing weight erythrocytes washing . Incorrect weights: press one of the keybuttons to weigh emocomponents again. To accept the new values and send them to ArchimedeLINK press Picture 91: Reweight procedure erythrocytes washing. User Manual Revision 1.05 Page 67 of 105 USING ARCHIMEDE Now remove tubes and bags and press type or press to continue with another separation of the same to exit. If you need to interrupt the procedure either momentarily of definitively, press keybutton. Picture 92: Pause or Stop in procedure erythrocytes washing . Stop: press ArchimedeLINK. Pause: press Page 68 of 105 or or . Archimede will display the sealing page and send data to to continue the procedure. User Manual Revision 1.05 USING ARCHIMEDE 4.6.9 PROCEDURE 10 [a]UMBILICAL CORD This procedure is indicated for quadruple top & bottom bag to obtain erythrocytes (RCC), plasma (PPP), and buffy coat (BC) diluted with plasma added through a press. Parameters used: 11 12 13 15 18 25 32 40 41 42 43 44 45 46 47 During the procedure, checks that tubes are properly inserted into the clamps enabled for the ongoing procedure. Enables the routine controlling breaking of the primary bag cannulas. Force in xx.x Kg beyond which the plate stops and waits for cannulas breaking. Plate forward moving speed during cannulas breaking step. Value used to calculate the force value below which the systems exits the cannulas breaking routine. V =(force measured at breaking position) â (current force). Value minimal of difference of reading between RBC and plasma with which it comes controlled the bag before and during the procedure. Sensibility HB sensor. Value of the maximum force applied during the procedure; the plate stops if the force exceeds this limit. Selection of the sealing mode. In automatic mode, the system automatically seals the bags when the procedure is over. In manual mode, bags sealing must be confirmed. Selection of clamps to be used for sealing when the procedure is over. Clamps are numbered as follows: 1 Top, 2 Plasma, 4 Buffy, 8 Bottom. The value to be set in this position is the value corresponding to the sum of the clamps used: for example, if bottom and top are to be used, the value to be set is 9. Plate moving speed used in the first phase for the management of force. Number identifying the IR sensor dedicated to buffy coat level. Buffy coat target value. Tare of the primary bag. This value is used to calculate the product amount left in the primary bag [current weight - tare] Sensibility flow valve. (Clamp 6) Value allowing to select the clamps to be used in the procedure. Number of the profile plate to be used with the ongoing procedure. Enables the air elimination routine. Primary bag positioning with blade ready for weighing. Scale stability check. Check Correlation Distance Weight. Enable scale reading. IR corresponding to upper and lower bag edges. User Manual Revision 1.05 Page 69 of 105 USING ARCHIMEDE Position bags and tubes according to the below sequence. Be sure to avoid tensions and folds that might cause flow obstruction or weighing errors. Scale 2 Clamp 1 Clamp 6 Scale 3 Clamp 4 HB sensor Primary bag Scale 1 Sag. M. bag Picture 93: Kit installation procedure umbilical cord NOTE: Tubes in the various kits have different lengths. To simplify kits management, the firmware allows to configure which valves you wish to enable. Picture 94: Position primary bag umbilical cord procedure. Hang the primary bag to the bag holders on the front panel. The label containing bag data should always be turned outside. Picture 95: Position plasma, RBC bag of umbilical cord procedure. Open cover of HB sensor and insert the tube coming from the primary bag into the reading area. Close the cover. Insert the tube coming from HB sensor into clamp 6. Insert the tube coming from clamp 6 into clamp 3. Position the plasma bag on upper scale. Insert bottom tube into clamp 4. Position the RBC bag on lateral scale. Page 70 of 105 User Manual Revision 1.05 USING ARCHIMEDE Picture 96: Erythrocytes umbilical cord in position. Archimede checks correct tubes positioning inside proper clamps by mens of its optical sensors. The tube is correctly inserted when the clamp number is replaced by the icon Press key-button to start the procedure. If the primary bag expected weight check has been enabled through ArchimedeLINK and the detected weight does not fall within the set limits, a warning will be displayed showing both or limits and current weight. After verifying the cause of the problem, confirm weight with to leave the procedure. Furthermore, if the tube presence check is enabled the press display will show the clamp numbers where tubes are not correctly inserted and the procedure will not start until all tubes are correctly inserted into the enabled clapms Now wait for the plate to get close to the bag. The plate will exert a force corresponding to the value set in the procedure parameters. Parameters of ongoing phase: #13: #18: #8: Plate forward moving speed Action distance between phases RBC action threshold Picture 97: Break cannulas view umbilical cord procedure. Break the cannulas by forcing on their side upper part. Wait for a few seconds that positive pressure is released. After detecting pressure decrease, Archimede automatically starts the separation cycle. If pressure does not decrease below the set value, due to tube obstruction or keybutton. fluid clogging, it is anyway possible to force the cycle start by pressing During the procedure, possible comments can be read on the external part of the fix front plate. The graphic interface will now show the current operating phase number, and the weight value of plasma collected. Archimede will check the buffy coat level through IR sensors, flow valve and valves 3, and 4. The distance sensor will stop the separation process when the plate reaches the distance set in the procedure parameters. ATTENTION: THE FORCE SENSOR IS ENABLED ONLY WHEN THE PLATE MOVES TOWARDS THE INSTRUMENT BODY. CAUTION: DO NOT PUT YOUR HANDS IN THE PLATE WORKING AREA WHEN THE PLATE IS MOVING. The sealing cycle depends on the value set in the procedure parameters: User Manual Revision 1.05 Page 71 of 105 USING ARCHIMEDE Automatic sealing: Manual sealing: sealing cycle of the selected clamps is performed automatically. press keybutton to seal the enabled lines, or press continue, after confirming, without sealing. to Picture 98: Sealing umbilical cord procedure. Archimede will automatically send to ArchimedeLINK all events and data of the procedure performed. At the end of the procedure the display will show the detected weights. If they are not the expected ones, because tubes are not correctly placed and distort scalesâ readings, the emocomponents can be weighed again after correcting tubesâ position and the new weights can be sent to ArchimedeLINK again. Correct weights: press keybutton to continue with the same type of separation or press to go back to the page listing the procedures. Picture 99: Viewing weight umbilical cord procedure Incorrect weiths: press one of the keybuttons to weigh emocomponents again. To accept the new values and send them to ArchimedeLINK press Picture 100: Reweight umbilical cord procedure. Now remove tubes and bags and press type or press Page 72 of 105 to continue with another separation of the same to exit. User Manual Revision 1.05 USING ARCHIMEDE If you need to interrupt the procedure either momentarily or definitively, press keybutton. Picture 101: Pause or Stop procedure umbilical cord. Stop: press ArchimedeLINK. Pause: press or or User Manual Revision 1.05 . Archimede will display the sealing page and send data to to continue the procedure. Page 73 of 105 USING ARCHIMEDE 4.6.10 PROCEDURE 11 [b] ALIQUOT SEPARATION This procedure allows to separate emocomponents in the four available bags by weighing them separately. Parameters used: 11 12 13 14 18 25 29 39 40 41 42 43 44 45 46 47 During the procedure, checks that tubes are properly inserted into the clamps enabled for the ongoing procedure. Enables the routine controlling breaking of the primary bag cannulas. Force in xx.x Kg beyond which the plate stops and waits for cannulas breaking. Plate forward moving speed during cannulas breaking step. Value used to calculate the force value below which the systems exits the cannulas breaking routine. V =(force measured at breaking position) â (current force). Value of the maximum force applied during the procedure; the plate stops if the force exceeds this limit. Selection of the sealing mode. In automatic mode, the system automatically seals the bags when the procedure is over. In manual mode, bags sealing must be confirmed. Selection of clamps to be used for sealing when the procedure is over. Clamps are numbered as follows: 1 Top, 2 Plasma, 4 Buffy, 8 Bottom. The value to be set in this position is the value corresponding to the sum of the clamps used: for example, if bottom and top are to be used, the value to be set is 9. Plate moving speed used in the first phase for the management of force. Weight of aliquot 2. (Upper scale) Value of the distance beyond which the system, after confirmation, stops the procedure if the set volumes have not been dispensed. Tare of the primary bag. This value is used to calculate the product amount left in the primary bag [current weight - tare]. Weight of aliquot 1. (Upper scale) Weight of aliquot 3. (Lateral scale) Value allowing to select the clamps to be used in the procedure. Number of the profile plate to be used with the ongoing procedure. Enables the air elimination routine. Primary bag positioning with blade ready for weighing. Scale stability check. Check Correlation Distance Weight. Enable scale reading. IR corresponding to upper and lower bag edges. Page 74 of 105 User Manual Revision 1.05 USING ARCHIMEDE Position bags and tubes according to the below sequence. Be sure to avoid tensions and folds that might cause flow obstruction or weighing errors. Scale 2 Clamp 3 Clamp 2 Scale 3 Clamp 1 Primary bag Scale 1 Picture 102: Kit installation aliquot separation procedure. NOTE: Tubes in the various kits have different lengths. To simplify kits management, the firmware allows to configure which valves you wish to enable. Picture 103: Position primary bag aliquot separation procedure. Hang the primary bag to the bag holders on the front panel. The label containing bag data should always be turned outside. Picture 104: Position aliquot separation procedure. bag. Insert tubes from the bags on upper scale firmly into clamps 1 and 3. Insert tubes from the bags on lateral scale firmly into clamp 2. User Manual Revision 1.05 Page 75 of 105 USING ARCHIMEDE Picture 105: Aliquot separation procedure bag in position. Archimede checks correct tubes positioning inside proper clamps by mens of its optical sensors. The tube is correctly inserted when the clamp number is replaced by the icon Press key-button to start the procedure. If the primary bag expected weight check has been enabled through ArchimedeLINK and the detected weight does not fall within the set limits, a warning will be displayed showing both or limits and current weight. After verifying the cause of the problem, confirm weight with to leave the procedure. Furthermore, if the tube presence check is enabled the press display will show the clamp numbers where tubes are not correctly inserted and the procedure will not start until all tubes are correctly inserted into the enabled clapms Now wait for the plate to get close to the bag. The plate will exert a force corresponding to the value set in the procedure parameters. Parameters of the ongoing phase: #13: Plate forward moving speed. Picture 106: Break cannulas view aliquot separation procedure. Break the cannulas by forcing on the side upper part of the cannula. Wait for a few seconds that positive pressure is released. During the procedure, possible comments can be read on the external part of the fix front plate. The graphic interface will now show the current operating phase number, and the weight value of plasma collected. Archimede will check the bags weights. When the desired volume is reached, the relevant clamp will be close. After the last aliquot the plate will move backwards to standby position. ATTENTION: THE FORCE SENSOR IS ENABLED ONLY WHEN THE PLATE MOVES TOWARDS THE INSTRUMENT BODY. CAUTION: DO NOT PUT YOUR HANDS IN THE PLATE WORKING AREA WHEN THE PLATE IS MOVING. At the end of the procedure the display will show the detected weights. If they are not the expected ones, because tubes are not correctly placed and distort scalesâ readings, the Page 76 of 105 User Manual Revision 1.05 USING ARCHIMEDE emocomponents can be weighed again after correcting tubesâ position and the new weights can be sent to ArchimedeLINK. Correct weights: press keybutton to continue with the same type of separation or press to go back to the page listing the procedures. Picture 107: Viewing weight aliquot separation procedure. Incorrect weights: prss one of the keybuttons to weigh emocomponents again. To accept the new values and send them to ArchimedeLINK press Picture 108: Reweight aliquot separation procedure. The sealing cycle depends on the value set in the procedure parameters: Automatic sealing: sealing cycle of the selected clamps is performed automatically. press keybutton to seal the enabled lines, or press Manual sealing: continue, after confirming, without sealing. to Picture 109: Sealing in aliquot separation procedure Archimede will automatically send to ArchimedeLINK all events and data of the procedure performed. Now remove tubes and bags and press type ore press to continue with another separation of the same to exit. User Manual Revision 1.05 Page 77 of 105 USING ARCHIMEDE If you need to interrupt the procedure either momentarily or definitively, press keybutton. Picture 110: Pause or Stop aliquot separation. Stop: press ArchimedeLINK. Pause: press Page 78 of 105 or or . Archimede will display the sealing page and send data to to continue the procedure. User Manual Revision 1.05 USING ARCHIMEDE 4.6.11 PROCEDURE 13 [d] T & T for RCC diluted in Plasma + Predefined HCT. This procedure is suitable for triple bags to obtain diluted RCC in plasma with predefined haematocrit (no additive solution) and PPP. Parameters used: 11 12 13 15 18 25 40 41 42 43 44 45 46 47 During the procedure, checks that tubes are properly inserted into the clamps enabled for the ongoing procedure. Enables the routine controlling breaking of the primary bag cannulas. Force in xx.x Kg beyond which the plate stops and waits for cannulas breaking. Plate forward moving speed during cannulas breaking step. Value used to calculate the force value below which the systems exits the cannulas breaking routine. V =(force measured at breaking position) â (current force). Value minimal of difference of reading between RBC and plasma with which it comes controlled the bag before and during the procedure Value of the maximum force applied during the procedure; the plate stops if the force exceeds this limit. Selection of the sealing mode. In automatic mode, the system automatically seals the bags when the procedure is over. In manual mode, bags sealing must be confirmed. Selection of clamps to be used for sealing when the procedure is over. Clamps are numbered as follows: 1 Top, 2 Plasma, 4 Buffy, 8 Bottom. The value to be set in this position is the value corresponding to the sum of the clamps used: for example, if bottom and top are to be used, the value to be set is 9. Plate moving speed used in the first phase for the management of force Haematocrit target. Value of the distance beyond which the system, after confirmation, stops the procedure if no RBCs have been detected. Tare of the primary bag. This value is used to calculate the product amount left in the primary bag [current weight - tare] Value allowing to select the clamps to be used in the procedure. Number of the profile plate to be used with the ongoing procedure. Enables the air elimination routine. Primary bag positioning with blade ready for weighing. Scale stability check. Check Correlation Distance Weight. Enable scale reading. IR corresponding to upper and lower bag edges. User Manual Revision 1.05 Page 79 of 105 USING ARCHIMEDE Position bags and tubes according to the below sequence. Be sure to avoid tensions and folds that might cause flow obstruction or weighing errors. Scale 2 Clamp 3 RBC Sensor Primary bag Scale 1 Picture 111: Kit installation procedure T & T with predefined HCT. NOTE: .Tubes in the various kits have different lengths. To simplify kits management, the firmware allows to configure which valves you wish to enable. Picture 112: Position primary bag T & T with predefined HCT procedure. Hang the primary bag to the bag holders on the front panel. The label containing bag data should always be turned outside. Picture 113: Position plasma bag T & T with predefined HCT procedure. Open the cover of HB sensor and insert the tube coming from the primary bag into the reading area. Close the cover. Insert the tube coming from the HB sensor firmly into clamp 3. Position the plasma bag on upper scale. Page 80 of 105 User Manual Revision 1.05 USING ARCHIMEDE Picture 114: T & T with predefined HCT procedure bag in position. Archimede checks correct tubes positioning inside proper clamps by mens of its optical sensors. The tube is correctly inserted when the clamp number is replaced by the icon Press key-button to start the procedure. If the primary bag expected weight check has been enabled through ArchimedeLINK and the detected weight does not fall within the set limits, a warning will be displayed showing both or limits and current weight. After verifying the cause of the problem, confirm weight with to leave the procedure. Furthermore, if the tube presence check is enabled the press display will show the clamp numbers where tubes are not correctly inserted and the procedure will not start until all tubes are correctly inserted into the enabled clapms Now wait for the plate to get close to the bag. The plate will exert a force corresponding to the value set in the procedure parameters. Parameters of the ongoing phase: #13: Plate forward moving speed #18: Action distance #15: Haematocrit target Picture 115: Break cannulas view procedure T & T with predefined HCT. Brake the cannulas by forcing on the side upper part of the cannula. Wait for a few seconds that positive pressure is released. After detecting pressure decrease, Archimede automatically starts the separation cycle. If pressure does not decrease below the set value, due to tube obstruction or fluid clogging, it is anyway possible to force the cycle start by pressing keybutton. During the procedure, possible comments can be read on the external part of the fix front plate. The graphic interface will now show the current operating phase number, and the weight value of plasma collected. Archimede will check the erythrocytes level and distance in primary bag. When this level reaches the HCT target will stop and the plate will move backwards. ATTENTION: THE FORCE SENSOR IS ENABLED ONLY WHEN THE PLATE MOVES TOWARDS THE INSTRUMENT BODY. CAUTION: DO NOT PUT YOUR HANDS IN THE PLATE WORKING AREA WHEN THE PLATE IS MOVING. The sealing cycle depends on the value set in the procedure parameters: Automatic sealing: sealing cycle of the selected clamps is performed automatically. User Manual Revision 1.05 Page 81 of 105 USING ARCHIMEDE Manual sealing: press keybutton to seal the enabled lines, or press continue, after confirming, without sealing. to Picture 116: Sealing procedure RCC T & T with predefined HCT. Archimede will automatically send to ArchimedeLINK all events and data of the procedure performed. At the end of the procedure the display will show the detected weights. If they are not the expected ones, because tubes are not correctly placed and distort scalesâ readings, the emocomponents can be weighed again after correcting tubesâ position and the new weights can be sent to ArchimedeLINK again. Correct weights: press keybutton to continue with the same type of separation or press to go back to the page listing the procedures. Picture 117: Viewing RCC T & T with predefined HCT procedure. Incorrect weights: press one of the keybuttons to weigh emocomponents again. To accept the new values and send them to ArchimedeLINK press Picture 118: Reweight T & T with predefined HCT procedure. With ArchimedeLINK the normal limits check can be activated. If it is enabled and the detected weights do not fall within the set limits, the display will show the emocomponentsâ detected weights and the allowed limits. Press any key to continue. Page 82 of 105 User Manual Revision 1.05 USING ARCHIMEDE Picture 119: RCC T & T with predefined HCT procedure with weight out of normal range. Correct weights: press keybutton to continue with the same type of separation or press to go back to the page listing the procedures. Incorrect weights: press one of the keybuttons to weigh emocomponents again. To accept the new values and send them to ArchimedeLINK press Now remove tubes and bags and press type or press to continue with another separation of the same to exit. If you need to interrupt the procedure either momentarily or definitively, press keybutton. Picture 120: Pause or Stop procedure RCC T & T with predefined HCT. Stop: press ArchimedeLINK. Pause: press or or User Manual Revision 1.05 . Archimede will display the sealing page and send data to to continue the procedure. Page 83 of 105 USING ARCHIMEDE Page 84 of 105 User Manual Revision 1.05 CALIBRATION SCALE CALIBRATION Scale calibration can be performed only when Archimede has been switched on for a few minutes. This is necessary for measuring sensors to reach thermal stabilization. A set of certified sample weights is also necessary. To enter calibration, press the keybutton above the icon, and select CALIBRATION using direction keybuttons. Picture 121: Calibration menu. Confirm by pressing Picture 122: Calibration, sample weight setting. Select the sample weight value you intend to use for calibration using confirm pressing keybuttons, then Picture 123: First step calibration. To perform tare, remove any weight from the front scale and then confirm pressing Picture 124: Second step calibration. Position the selected sample weight. When the displayed value is stable to confirm. Repeat the above steps with upper scale (2) and lateral scale (3). User Manual Revision 1.05 Page 85 of 105 CALIBRATION Picture 125: Calibration, calibration factors display. Verify calibration factors calculated for front scale (1), upper scale (2), and lateral scale (3). Press factors. to confirm factors and save them, or press Page 86 of 105 to restore the previous calibration User Manual Revision 1.05 DATA TRANSFER DATA TRANSFER When the WLAN option is installed, Archimede can dialogue in bidirectional mode with ArchimedeLINK. This allows data transfer from more Archimede units, even if located several meters distant from the PC where ArchimedeLINK server is installed. The maximum possible distance is about 50 meters, depending on environment and disturbances that might be present. 6.1 WLAN Picture 126: WLAN connection A 802.11 b/g wireless LAN should be installed on the PC to be used. Communication takes place through the identification of Archimedeâs univocal serial number. This allows ArchimedeLINK to communicate with more units installed and switched on within a 50 meters distance. Designed by manufacturer for exclusive connection to the instrument according to the prescriptions contained in the specific documentation of that instrument and to EN60950 Regulation. 6.2 Firmware Update and Procedures Protocols ⢠The use of ArchimedeLINK allows to: ⢠Update Archimedeâs internal firmware. Firmware updating should preferably be performed by qualified engines authorized by manufacturer. ⢠Enter new procedures, up to a maximum of 18. New procedures creation should preferably be performed by application engineers having detailed knowledge of the various procedure parameters functions. ⢠Modify procedure parameters. This should be done by trained operators, or by application engineers in order to avoid entering unsuitable values for the regular bag press operation. ⢠Verify correct operation of all peripheral units connected to Archimede. This operation should be performed by qualified engineers authorized by manufacturer. User Manual Revision 1.05 Page 87 of 105 DATA TRANSFER 6.3 Data transmission and reception Data concerning the ongoing procedure are sent both during the procedure and at the end of the procedure, with a round-up of all data acquired. During the initial phase, Archimede sends Archimedeâs univocal serial number, the procedure number and date and time of procedure beginning. In the final phase it sends all procedure data and events or errors, if any. Comunication Request from Archimede ArchimedeLINK STXID|ENQ|XOR|ETX ID is serial number. Lenght max 4 digit zero included. STXID|NAK|XOR|ETX SN NOK? Busy? Yes Exit No STXID|ACK|XOR|ETX OK for comunicazion STXID|âŚâŚ..|XOR|ETX Send Function Comand Comand OK No Yes 3 NAK sent? Yes Exit No STXID|NAK|XOR|ETX No 3 NAK Received ? Yes Manage request Exit Picture 127: Communication request from Archimede Page 88 of 105 User Manual Revision 1.05 DATA TRANSFER Picture 128: Communication request from ArchimedeLINK User Manual Revision 1.05 Page 89 of 105 DATA TRANSFER 6.3.1 Example of procedure data transmission: Procedure preparation # STXxxxx|0d|yy|XOR|ETX STXxxxx|ACK|XOR|ETX Procedure start # STXxxxx|0e|yy|XOR|ETX STXxxxx|ACK|XOR|ETX Sealing in progress #ď STXxxxx|0f|yy|XOR|ETX STXxxxx|ACK|XOR|ETX Procedure run and relevant data #ď STXxxxx|0g|yy|OP|BC0|BC1|BC2|BC3|BC4|BC5|BC6|BC7|BC8|BC9| hh:mm:ss|hh:mm:ss|hh:mm:ss|gg/mm/aa| 1111|2222|3333|cccc|ffff|ssss|hh:mm:ss|Events|Errors|XOR|ETX STXxxxx|ACK|XOR|ETX 6.3.2 List of symbols used in the transmission protocol: Data transmission from Archimede to PC. Data transmission from PC to Archimede. STX Start of Text. Unit separator ACK Acknowledge XOR String control byte ETX End of Text xxxx Archimedeâs univocal serial number 0d Data string ID: procedure preparation 0e Data string ID: procedure start 0f Data string ID: sealing in progress 0g Data string ID: procedure run and relevant data yy Procedure number OP Operator code BC 0,1,2,3,4,5,6,7,8,9 data read by barcode reader hh:mm:ss 1st field procedure start time, 2nd field sealing start time, 3rd field time and date procedure end Weight of frontal scale 2222 Weight of upper scale 3333 Weight of lateral scale cccc Amount of plasma used for cleaning ffff Amount of plasma used for filter ssss Amount of Sag.M. Events Evens occurred during procedure Errors Errors occurred during procedure Page 90 of 105 User Manual Revision 1.05 TROUBLESHOOTING TROUBLESHOOTING Archimede checks continuously that the peripheral units connected work correctly. In case it detects an error that cannot be eliminated through the dedicated algorithms, the instrument displays the error. 7.1 Errors and Possible Solutions Error 1A THE INSTRUMENT DOES NOT TURN ON. Cause 1: Remedy: Cause 2: Remedy: Error 2A DATE AND TIME LOSS. Cause 1: Remedy: Cause 2: Remedy: Error 3A Reset of RTC circuit due to big conducted interferences. Re-set date and time. RTC backup capacitor is exhausted. Call Authorized Service Center. THE DISPLAY SHOWS INCOMPREHENSIBLE CHARACTERS. Cause 1: Remedy: Error 4A Main power is lacking. Check that main voltage is present and that the power cord is correctly plugged. Fuse blown Replace burnt fuses with new ones of the type reported on data plate. Electronics interferences. Turn Archimede OFF and ON. Call Authorized Service Center. ARCHIMEDE DOES NOT CONNECT TO ARCHIMEDELINK. Cause 1: Remedy: Cause 2: Remedy: ArchimedeLINK is not enabled or Archimede network is disconnected. Enable ArchimedeLINK server. Connect to Archimede WLAN network. Check that Archimede and ArchimedeLINK server subnets are correct. Check firewall settings. Noisy communication. Check signal strength and ensure that Archimedeâs antenna is correctly screwed on and is not near metal objects. Bring access point or server nearer Archimede units. Change the WLAN module transmission channel. Call Authorized Service Center. 7.2 Errors with Archimede codes Error 1 E2PROM BUSY. Cause 1: Remedy: Cause 2: Remedy: Error 2 E2prom memory stuck or defective. Turn Archimede OFF and ON. Defective microcontroller E2prom memory. Call Authorized Service Center. E2PROM VERIFY. Cause 1: Remedy: Cause 2: Remedy: User Manual Revision 1.05 E2PROM verify failed. Turn Archimede OFF and ON. Defective microcontroller E2prom memory. Call Authorized Service Center. Page 91 of 105 TROUBLESHOOTING Error 3 Error 4 Error 5 Error 6 Error 7 Error 8 Error 9 SPI TIMEOUT Cause 1: One peripheral unit has unexpectedly interrupted the communication. Remedy: Turn the instrument OFF and ON. Cause 2: Defective CPU or SO board. Remedy: Call Authorized Service Center. RFID TIMEOUT Cause 1: Defective RFID label. Remedy: Replace RFID label. Cause 2: RFID module is not responding. Remedy: Turn the instrument OFF and ON. RFID COMUNICATION ERROR Cause 1: RFID data are corrupted. Remedy: Turn the instrument OFF and ON. CORRUPTED BOOT LOADER Cause 1: Checksum of boot loader routine is not correct. Remedy: Call Authorized Service Center. CORRUPTED FIRMWARE Cause 1: Checksum of firmware is not correct. Remedy: Download firmware by ALNK. WRONG CALIBRATION DATE Cause 1: Data loss or corrupted. Remedy: Run scales calibration. PARAMETER OVER RANGE Cause 1: Remedy: Error 10 (1-4) AD CONVERTER IS IN OVERFLOW. Cause 1: Remedy: Error 11 (1-4) Error 13 (1-4) A/D converter stuck. Turn Archimede OFF and ON. ADC UNDERFLOW DURING SCALE (X) TARE. Cause 1: Scale holder is not in correct position. Remedy: Check that scale holders are correctly mounted and free from obstructions. Turn Archimede OFF and ON. SCALE (X) TARE IS OVER LIMITS. Cause 1: Page 92 of 105 Incorrect analog power Check that scale holders are correctly mounted and free from obstructions. Turn Archimede OFF and ON. AD CONVERTER TIMEOUT. Cause 1: Remedy: Error 12 (1-4) During parameter check an error in parameter value has been detected. Run procedure update. Scale holder is not in correct position. AD input circuit not compensated. User Manual Revision 1.05 TROUBLESHOOTING Remedy: Error 14 (1-4) IN SEPARATION MODE TARE (X) VALUE IS OVER RANGE. Cause 1: Remedy: Error 15 (1-4) Remedy: Error 17 (1-10) Error 18 (1-10) Error 19 Error 20 Weight detection circuit output ⼠1000 mV. Remove any extra weight from the cradle. Call Authorized Service Center. K SCALES (X) VALUE OVERRANGE. Cause 1: Error 16 (1-10) Check that scale holders are correctly mounted and free from obstructions. Turn Archimede OFF and ON. During calibration, the system has checked that scales calibration factor is over limit. The value of standard weight in use does not correspond to the value set during calibration.. Repeat calibration. Call Authorized Service Center. LUMINOSITY. Cause 1: There is too much light in the room. IR dark voltage > 500 mV. Remedy: Reduce environment luminosity. Cause 2: IR sensor is defective. Remedy: Call Authorized Service Center. IR SENSOR SENSITIVITY TOO LOW. Cause 1: IR sensor does not detect sufficient difference between lit and unlit led. Vtr < 4500mV with I led > 300 mA. Remedy: Clean IR sensors and yellow strip. Cause 2: IR sensors pair is defective. Remedy: Call Authorized Service Center. IR SENSOR SENSITIVITY TOO HIGH. Cause 1: IR sensor detects too much difference between lit and unlit led. Remedy: Reduce environment luminosity. Cause 2: IR sensors pair is defective. Remedy: Call Authorized Service Center. HB SENSOR SENSITIVITY TOO LOW. Cause 1: HB sensor does not detect sufficient variation between lit and unlit led. Remedy: Clean sensors. Cause 2: Green sensors is defective. Remedy: Call Authorized Service Center. HB SENSOR SENSITIVITY TOO HIGH. Cause 1: HB sensor detects too high variation between lit and unlit led. Remedy: Call Authorized Service Center. User Manual Revision 1.05 Page 93 of 105 TROUBLESHOOTING Error 21 PLATE OPENING MOVING TIME TO LIMIT POSITION >30 SECONDS. Cause 1: Error 22 Remedy: Mechanical obstructions prevent the pressing plate from reaching open position. Time > 30 seconds. Remove any obstruction. Clean support bars. Cause 2: Open position sensor defective. Remedy: Call Authorized Service Center. PLATE CLOSING MOVING TIME TO LIMIT POSITION >30 SECONDS. Cause 1: Error 23 Remedy: Mechanical obstructions prevent the pressing plate from reaching close position. Time > 30 seconds. Remove any obstruction. Clean support bars. Cause 2: Force sensor defective. Remedy: Call Authorized Service Center. BLADE MOVING TIME TO LIMIT POSITION >10 SECONDS. Cause 1: Error 24 Error 25 Error 26 Error 27 Remedy: Mechanical obstructions prevent the buffy coat separator from reaching open or close position within 10 seconds. Remove any obstruction, Clean blade assy. Cause 2: BC position sensor defective. Remedy: Call Authorized Service Center. PLATE POSITIONING TIME TO HOME POSITION >30 SECONDS. Cause 1: Mechanical obstructions prevent plate movement from reaching home position within 30 seconds.. Remedy: Remove any obstruction. Cause 2: Home position sensor defective. Remedy: Call Authorized Service Center. POSITIONING TIME OF IR CALIBRATION POSITION SENSOR > 10 SECONDS. Cause 1: Mechanical obstructions prevent plate movement from reaching IR calibration position within 10 seconds.. Remedy: Remove any obstruction. Cause 2: IR cal position sensor defective. Remedy: Call Authorized Service Center. PLATE ZERO-POSITION SENSOR OVER RANGE. Cause 1: Mechanical obstructions prevent plate movement from reaching zero position. Remedy: Remove any obstruction. Cause 2: Distance sensor defective. Remedy: Call Authorized Service Center. FORCE SENSOR HAS DETECTED STRESS >1 WITH PLATE FREE. Cause 1: Error 28 Remedy: Mechanical obstructions prevent to correlate between distance and force during self-check. Remove any obstruction. Cause 2: Force sensor is defective. Remedy: Call Authorized Service Center. CALIBRATION POSITION DISTANCE SENSOR VOLTAGE > 4600 mV. Cause 1: Page 94 of 105 values Mechanical obstructions prevent plate movement. User Manual Revision 1.05 TROUBLESHOOTING Error 29 (1-4) Error 30 Error 31 Error 32 (1-4) Error 33 Error 34 Remedy: Remove any obstruction. Cause 2: Defective linear sensor. Remedy: Call Authorized Service Center. WET OR DIRTY ELECTRODES IN SEALING HEAD. Cause 1: Sealing heads wet or dirty. Remedy: keybutton Clean and dry sealing headsâ electrodes. Press to open the clamp in error; insert tube again and press to perform sealing again. If a procedure is ongoing, press to continue. Cause 2: Defective sealing head or CSU. Remedy: Call Authorized Service Center. SEALING UNIT BUSY. Cause 1: CSU cable disconnected. Remedy: Check and connect cable. Cause 2: Defective CSU. Remedy: Call Authorized Service Center. TUBE IN THE CLAMP. Cause 1: Tubes are inserted to clamps during self-diagnosis. Remedy: Remove tubes from clamps and repeat self-diagnosis cycle. Cause 2: Defective tube sensor. Remedy: Call Authorized Service Center. ELEVATED LOAD CELLS OFFSET. Cause 1: Bags or weights positioned on the scales during selfdiagnosis. Remedy: Remove any bags or weights from the scales during selfdiagnosis cycle. Cause 2: Defective offset digital system. Remedy: Call Authorized Service Center ELEVATED FLOW-VALVE CHECK CYCLE. Cause 1: Valve-actuator movement is locked. Remedy: Remove tubes or any obstruction from the actuator and retry. Check if cable is inserted correctly. Replace flow valve assy. Cause 2: Defective position sensor. Remedy: Call Authorized Service Center. STEP NUMBER UNSUITABLE FOR COMPLETING ONE FLOW-VALVE CYCLE. Cause 1: Valve-actuator movement is locked. Remedy: Remove tubes or any obstruction from the actuator and retry. Check if cable is inserted correctly. Replace flow valve assy. Cause 2: Defective motor. Remedy: Call Authorized Service Center. User Manual Revision 1.05 Page 95 of 105 TROUBLESHOOTING Error 35 (1-3) Error 36 Error 37 CELL K OVER RANGE. Cause 1: In self test phase, during calibration factors check an error has been detected. Remedy: Ricalibrate all scales. FORCE SENSOR K OVER RANGE. Cause 1: In self test phase, during calibration factor check an error has been detected. Remedy: Ricalibrate force sensor. INSUFFICIENT PLASMA-PLT. Cause 1: Error 38 Error 39 Remedy: The plasma amount set in the procedure is higher than the amount collected. Verify actual value. Cause 2: Remedy: Scale not calibrated. Calibrate scale. INSUFFICIENT PLASMA WEIGHT. Cause 1: During separation plasma weight is not adequate. Remedy: Check that the cannula has broken and that there are no obstructions; then go on. INSUFFICIENT BUFFY-COAT. Cause 1: Error 40 Error 41 Error 42 Remedy: The buffy-coat amount set in the procedure is higher than the amount collected. Verify actual value. Cause 2: Scale not calibrated. Remedy: Calibrate scale. (see scale calibration) INSUFFICIENT SAG-M WEIGHT. Cause 1: Sag-M amount is insufficient to complete the procedure. Remedy: Check actual amount and confirm. Cause 2: Scale not calibrated. Remedy: Calibrate scale (see scale calibration). CHECK SAG-M FLOW. Cause 1: Remedy: Sag-M tube folded or collapsed. Adjust bag tube and remove obstructions. Cause 2: Remedy: Clamp 5 closed. Unlock clamp 5. Call Authorized Service Center. Cause 3: Remedy: Scale not calibrated. Calibrate scale (see scale calibration). LIMIT SWITCH REACHED WITH INSUFFICIENT SAG-M. Cause 1: Error 43 Page 96 of 105 Remedy: Sag-M bag lacking. The system has detected the allopened-plate sensor without dispensing Sag-M. Position Sag-M bag. Cause 2: Remedy: Defective open-plate sensor. Call Authorized Service Center. RBCS NOT DETECTED. User Manual Revision 1.05 TROUBLESHOOTING Error 44 Cause 1: Wrong action threshold. Remedy: Check value of parameters 8. Cause 2: Wrong distance threshold. Remedy: Check value of parameters 18. Cause 3: Insufficient erythrocytes amount. Remedy: Repeat procedure. Cause 4: Defective HB sensor. Remedy: Call Authorized Service Center. CHECK FLOW. Cause 1: Obstructed filter. Remedy: Retry with a new bags set. Cause 2: Tubes poorly positioned. Remedy: Relocate tubes. Cause 3: Scale not calibrated. Remedy: Calibrate scale (see scale calibration). Error 45 NOT IN USE. Error 46 UNEXPECTED WEIGHT. Error 47 Cause 1: Scale weight has had a sudden variation due to an external agent. Remedy: Check that foreign objects are not on the scales and remove it. Cause 2: Scale unstable. Remedy: Check if scale holder donât touch against metal plate. Call Authorized Service Center. BARCODE TOO LONG. Cause 1: Error 48 Error 50 Remedy: Barcode not compatible with the system. The maximum possible length is 20 characters including the control character. Read a compatible code. Cause 2: Barcode reader set improperly. Remedy: Reconfiguration configuration). barcode (see Datalogic barcode PROCEDURE HAS BEEN INTERRUPTED BY THE OPERATOR. Cause 1: key-button and confirmed The operator has pressed interruption with key-button. Remedy: Repeat procedure. ERROR DISTANCE-WEIGHT. Cause 1: Remedy: Error 51 of The plate is in position where weight measured must be more. Verify any obstructions that may create false weight readings. Check bag setting parameters. ERRORE PESATA-DISTANZA. Cause 1: The plate is in position where weight measured must be less. User Manual Revision 1.05 Page 97 of 105 TROUBLESHOOTING Remedy: Verify any obstructions that may create false weight readings. Check bag setting parameters. Error 52 TIMEOUT PLATE. Cause 1: The distance detected did not change over the last 18 seconds. Remedy: Verify any obstructions of the tubes and proper breaking of cannula. Error 53 (1-6) HIGH SENSOR TUBE LIGHT. Cause 1: Ambient light detected by the sensor tube x is too high. Remedy: Reduce ambient light. Change tube sensor (x). Page 98 of 105 User Manual Revision 1.05 MAINTENANCE Maintenance Archimede requires very little maintenance. It simply consists in keeping clean case, clamps, flow valve, optical sensors and the weighing system calibration control. 8.1 Daily Maintenance 8.1.1 Cleaning Clean upper scale tray and holder with detergent or disinfectant; avoid hitting the mechanical device supporting the tray and do not pour liquids inside the central gap. Clean clamps hollow and its actuator with a wet cotton wad. Clean Archimede case with disinfectant. Keyboard and optical sensors should be cleaned only with a cloth dampened with water. Never use alcohol, acetone, trichloroethylene or any solvents. 8.1.2 Decontamination Remove the upper scale tray and decontaminate both tray and holder with bleach or disinfectant. Do not hit the mechanical device supporting the tray and do not pour liquids inside the central gap. Decontaminate also flow-valve actuator, clamps actuators and optical sensors with a cotton fioc dampened with bleach or disinfectant. Rinse with water all parts treated with bleach or disinfectant. Never use alcohol, acetone, trichloroethylene or any solvents. 8.1.3 Monthly Maintenance Monthly maintenance simply consists of checking scales calibration. The check should be performed by a certificate centre with certified weights. If the reading does not fall within the allowed range, please contact the authorized technical service centre. 8.2 Yearly Maintenance Yearly maintenance is performed by qualified engineers authorized by manufacturer. Before cleaning with any liquid, turn Archimede off and disconnect the power cable. 8.3 Maintenance Recording This function is enabled only when Archimede is connected to ArchimedeLINK. In this case, all maintenance operations can be stored sending to ArchimedeLINK data relevant to maintenance, operator, and date of performance. To confirm the action done, select the desired maintenance using the arrows and read the operator code. , confirm with Picture 129: Maintenance view User Manual Revision 1.05 Page 99 of 105 MAINTENANCE Page 100 of 105 User Manual Revision 1.05 OPTIONAL ACCESSORIES ACCESSORIES Archimede can be supplied with: RFID reader for labels or cards type RFID ISO15693. Supported tags are I.CODE SLI and Tag_it. Omnidirectional bar code reader. User Manual Revision 1.05 Page 101 of 105 OPTIONAL ACCESSORIES Page 102 of 105 User Manual Revision 1.05 DISPOSAL 10 DISPOSAL When disposing materials, please observe the following recommendations: 10.1 Packing Material Disposal ⢠Throw packing materials in the proper separate collection containers. ⢠In case of doubts, please ask the blood centre chief for information about proper separate collection. 10.2 Archimede Disposal ⢠If Archimede is no longer usable, please bring it to the area separate collection centre or ⢠Ask the nearest Technical Service authorized centre. Separate waste collection. Discard separately. User Manual Revision 1.05 Page 103 of 105 DISPOSAL Page 104 of 105 User Manual Revision 1.05 TECHNICAL FEATURES 11 TECHNICAL FEATURES ⢠Painted metal case. ⢠Graphic backlight display 240 x 128. ⢠N° 3 load cells for 2 kg: non linearity 0,02% F.S., repeatability 0,02% F.S., resolution Âą 1 g. ⢠Detection system of force exerted by the plate. ⢠N° 4 sealing head clamps, 1 normal clamp, and one flow valve. ⢠N° 10 optical sensor to detect buffy coat level. ⢠Optical device to detect red blood cells presence. ⢠Many separation procedures stored, up to a maximum of 18. ⢠WLAN for bi-directional data transfer of procedure and configuration data. ⢠PS2 port for external barcode-reader connection. ⢠Adjustable sealing time from 0.5 to 4 seconds, frequency 40.68 MHz. ⢠Environmental requirements: Temperature between 5°C and 45°C Humidity lower than 80% without condensation. ⢠Power supply: 90 VAC 84 W 1A, 230 VAC 81 W 0.4A, fuses 2.0 AT. ⢠Dimensions Width 435, depth 500, height 425 [mm]. ⢠Weight: 40Kg ⢠Transport and storage From â20°C to +70°C. Relative humidity from temperature 20% to 90% without condensation. ⢠In accordance with: EN60601-1-2 (2001-11) IEC60601-1-2 (2001-09) EN60601-1:1990-08+ EN60601-1/Ec :1994-07 + EN60601-1/A1:1993+EN60601-1/A1/Ec:1994-07 + EN60601-1/A2:1995-06 + EN60601-1/A13:1996-01. EN60950-1(2001) + A1 EN301 489-17 V1.2.1 (2002-08). EN301 489-1 V1.6.1 (2005-09). ⢠Electrical safety: Class I â Instrument with applied part Type B. Rule 12 MDD 93/42 â Device belonging to Class I without measurement function. Instrument not suitable for use in the presence of flammable anaesthetic mixtures with air or oxygen or nitrous oxide. Instrument for continuous working. ⢠Instrument in compliance with MDD 93/42 EEC requirements. ⢠International protection: IP41. ⢠FCC ID: V991504. MOELCA s.r.l. Sede Legale Via E.Toti,101 Uffici Via del Lavoro,19. 22070 Limido Comasco (CO) 031-3520153 3520279 3524739. Fax 031-3524732 Email: info@moelca.it User Manual Revision 1.05 Page 105 of 105
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Format : application/pdf Title : Microsoft Word - User Manual Rev. 1.05.doc Creator : Claudio Create Date : 2009:06:09 09:59:46+02:00 Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2009:06:09 09:59:46+02:00 Producer : Acrobat Distiller 8.1.0 (Windows) Document ID : uuid:5fb19376-673f-494f-b648-929ae291c2aa Instance ID : uuid:813b6aa0-33b9-4dd0-9214-094befa225a6 Page Count : 105 Author : ClaudioEXIF Metadata provided by EXIF.tools