MUL T LOCK TECHNOLOGIES ENTRWRF00 ENTR Fingerprint Reader User Manual ENTRR Fingerprint Reader FCC IC

MUL-T-LOCK TECHNOLOGIES LTD ENTR Fingerprint Reader ENTRR Fingerprint Reader FCC IC

Contents

Users Manual-Part 1 (1-20).pdf

Download: MUL T LOCK TECHNOLOGIES ENTRWRF00 ENTR Fingerprint Reader User Manual ENTRR Fingerprint Reader  FCC IC
Mirror Download [FCC.gov]MUL T LOCK TECHNOLOGIES ENTRWRF00 ENTR Fingerprint Reader User Manual ENTRR Fingerprint Reader  FCC IC
Document ID3248338
Application IDCvm6CGo9ezCJ/Qf/KH7uVw==
Document DescriptionUsers Manual-Part 1 (1-20).pdf
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize369.8kB (4622529 bits)
Date Submitted2017-01-05 00:00:00
Date Available2017-07-04 00:00:00
Creation Date2016-12-28 10:52:51
Producing SoftwarePDF-XChange Viewer [Version: 2.0 (Build 40.7) (Nov 25 2008; 17:31:42)]
Document Lastmod2016-12-28 10:54:23
Document TitleENTRR Fingerprint Reader_user manual_FCC,IC.pdf
Document CreatorPDFCreator Version 1.2.3
Document Author: suhsiao

Y I ENTR‘ I
EMUL-T-LDCK' m:
Table of Content
1. Cylinder Installation 5
1.1 Package Content 5
1.2 Tools Requirements ............................................................... 5
1.3 Prior to Installation ................................................................ 6
1.4 Cylinder & Unit Installation ................................................................... 6
1.5 Magnet Fitting ............ 8
2. ENTR® Description 9
2.1 ENTRG’ Description .............................................................. 9
2.2 Indications .............................................................................................................................. 9
2-3 0N/0FF Switch ............................................................................................................................. 10
2.3.1 Switching the ENTRQ 0N .......................................................... 10
2.3.2 Switching the ENTR‘B7 OFF .......................................... . 10
2.33 Low Battery Indication .............................................................. 10
2.4 Initiating the Lock ................................................................. 11
2.5 Default PIN Code 11
3- Operation ..................................................................... 12
3.1 Changing PIN Code VVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVV 12
3.2 Door Configuration .............................................................. 13
3.3 Pairing Remote Control ................................................................................................................... 16
3.4 Deleting Remote Control .............................................................. 17
3.5 Setting the Sound Signal. .................................................. 18
3.6 Setting Locking Mode .............................................................. 19
3-7 Operated by Knob. .............................................................. ..20
3.8 Operated by Slide Buttons 20
II ENTR® Dead Bolt User Manual
T I ENTR‘ I
.MUL-T-Locn'
mm; mm
4. Touchpad Reader 21
4.1 Changing PIN Code .............................................................. 21
4-2 Battery Replacement . .......................................................... 21
42.1 Low Battery Indication ...................................................... 21
5. Touchpad Reader Operation 22
5.1 Operation.
5.2 Pairing Touchpad Reader ............................................................... 22
5-3 Touchpad Reader Master PIN Code .......................................... 24
5.4 Menu Mode. ....................................................... 24
5.5 Adding Personal User Code ................................................. 24
5.6 Open Door ................................................................ 25
5.7 Lock Door ............................................................... 25
5.8 Delete Personal User Code .. ............................................. 25
5.9 Delete All Personal User Codes ...................................... 25
5.10 Volume Control 26
5.11 Factory Reset 25
6- Fingerprint Reader . ...................................................... 27
6.1 Mounting the Fingerprint Reader V ............................... 27
62 Battery Replacement .. .......................................................... 27
6.3 Adjust Date & Time 27
6.4 Pairing Fingerprint Reader ............................................................. 28
6.4.1 Add Master ....................................................................... 29
6.4.2 Set Finger 29
6.4.3 Set PIN Code 29
6.5 Unlock the Door 30
ENTR® Dead Bolt User Manual m
I. MUL-T-LDCK'
I ENTR‘ I
mm; mm
6.6 Lock Door 31
6.7 Low-battery Indication 31
6.8 Setting Menu 31
6.9 Add User ................................................................ 32
6.10 Delete User .............................................................. 33
6.11 Enable/Disable User ................................................................................. 33
6.12 Delete all Users ...................................................................... 34
6.13 Add Time Schedule 34
6.14 Edit Time Schedule 35
6.15 Volume Control 35
6.16 Double Security 36
6.17 Factory Reset 36
7- Smartphone App ............................................................................................................................. 37
7-1 APP Installation . .............................................................. 37
7-2 Pairing Smaitphone ............................................................ 38
8. Remote Control Battery Change 39
8-1 Battery Removal .......................................... .39
8.2 Battery Insertion
9. Troubleshooting 41
10.1 Limitations and External Influences 41
10.2 Cases 41
Limited warranty. ................................................. 44
Federal Communications Commission (FCC) Statement 47
ENTR® Dead Bolt User Manual
Y I ENTR‘ I
.MUL-T-Locn'
mm; “er:
1. Cylinder Installation
1.1 Package Content
1 Base plate & Knob 5 Battery charger
2 Electrical unit 6 Magnet
3 Mounting screw 7 Inside drive adapter
4 Panel screw 8 Mounting screws
9 Decorative spacer 10 Allen key #3
1.2 Tools Requirements
0 Small Phillips screwdriver
Note: Do not use power tools or any excessive force to assemble ENTR® parts.
ENTR® Dead Bolt User Manual 5
Y I ENTR‘ I
.MUL-T-Locx'
mm; mm
1.3 Prior to Installation
i Warning Do not attempt to operate the unit until assembled into the door
- Remove knob screw using 1/16" Allen key and take the knob out.
- Use a flat screwdriver to remove the cover.
- Remove both Allen screws entirely and remove internal mechanism.
Note: While removing the internal mechanism secure the outside cylinder from
falling. Consider using masking tape or similar.
%%-
Knob screw
Cover
1.4 Unit Installation
- Prior to installation check bolt locking direction.
- Verify that the bolt is in open position (bolt inside the door, unlocked).
. Rotate adapter tail—piece opposite to the bolt locking direction until stopped (see
below drawing #1).
0 Verify that the wide teeth is pointing up. If not rotate the external ring until the
wide teeth will point up (see below drawing #2).
Wide teeth
Bolt locking direction
‘-
Drawing #2
Drawing #1
Rotate adapter tail piece opposite
to the bolt locking direction
6 ENTR® Dead Bolt User Manual
Y I ENTR‘ I
EMUL-T-LDCK'
mm; mm
- Place the Inside drive adapter and tighten the
screws. Do not over tighten the screws or use
power tools.
- Place decorative spacer over the
Inside drive adapter.
- Assemble base plate (top
housing & knob).
- Tighten cylinder mounting screw.
U 7 Mounting screw
Decorative spacer
“’3
/ \ “/g Base plate
Note: In case the "Male rectangle" on the adapter is not aligned with the "Female
rectangle" on the Knob, the unit will not engage properly and may cause to malfunction.
Female rectangle Male rectangle Female rectangle
Pll
Adapter Adapter
ENTR® Dead Bolt User Manual 7
Y I ENTR‘ I
.MUL-T-anx'
mm; mm
- Carefully connect data cable plug.
- Assemble electrical unit panel (battery housing). attache to base
plate (1) and push down (2).
I Tighten electrical unit panel screw.
9 7 Panel screw
Electrical unit
Data cable plug
1.5 Magnet Fitting
Magnet Fitting:
- Mount the magnet on the frame
moldings, as close as possible to
the lock.
I The lower part of the magnet should
align with the lower point of the slider
(see illustration).
Note: The magnet area on frame molding
should be clean and free from dust,
peeling paint etc. Use alcohol if required.
Wait until completely dry prior to sticking.
8 ENTR® Dead Bolt User Manual
I, MUL-T-LDCK‘
I ENTR' I
mm mm
Z. ENTR® Description
2.1 ENTR® Description
2.2 Indications
Mute (Green)
fl
Door not closed (Red)
ON/OFF switch
Touchpad
Indications
Knob
Manual Mode (Green) OK (Green)
@ v
Battery status (Green/Red) Error (Red)
ENTR® Dead Bolt User Manual
I. MUL-T-LDCK'
I ENTR‘ I
mm; “er:
2.3 0N/OFF Switch
I Turning the ENTR® lock ON or OFF.
2.3.1 Switchin the ENTR® ON
Before turning ENTR® ON, verify that the
door is shut.
I Move the switch to the ON position.
Make sure that the knob is in the zero
position (see illustration).
I Function and numeric buttons will all
blink once.
I Hazard beep sound will be emitted and
error indication will blink once.
I ENTR® is now in operating mode.
Note:
I After turning ENTR® ON, avoid touching
the front panel until beep sound ends.
I After turning ENTR® ON, the door will be
shut but not locked.
2.3.2 Switching the ENTR® OFF
I Move the switch to OFF position.
2.3.3 Low battery indication
Zero position
Battery red signal rapidly blinking and 2 long beeps will be sounded during every
lock/unlock action, indicating that the battery is low and needs to be charged.
10
ENTR® Dead Bolt User Manual
Y I ENTR‘ I
.MUL-T-Locx' "a
2.4 Initialization of the Lock
Initiate the lock by touching the middle of the touch screen
with the palm of your hand or fingers for 3 seconds.
- Programing buttons and battery status indication light
will illuminate for 15 seconds, waiting for user's action.
- After 15 seconds of inactivity, ENTR® will idle.
2.5 Default PIN Code
The lock's default factory PIN code is: 1 2 3 4 5 #
Please note:
- Default PIN code must be changed before starting the configuration process.
I The PIN code must consist of 4—10 digits using numbers 1 through Sin any sequence.
0 Only the Code and Mute functions will operate until the default PIN code is changed.
I Warning: Don't forget/lose the PIN code once changed, otherwise you will be
locked out. Keep your new PIN code in a safe place.
ENTR® Dead Bolt User Manual 11
In MUL-T-LDCK'
3.
Operation
3.1 Changing PIN Code
Do not attempt to operate the unit until assembled
I ENTR‘ I
mm; mm
Touch screen with palm orfingers for
3 seconds to active.
Mute Clo Del
[OK] indication blinks once,
1 long beep emitted.
Illuminated buttons turn off.
Mute Cig [L'al
I 2 7
4 T T
.-.: H
ll]
ii
Numeric buttons illuminated.
Reenter [New PIN code] III‘ [It]
For example: 12312343:
Milie- ;:ng [Iel
1 2 3
4 5 #
MIA
U l]
w 'm)
ill» 2
Press [Code]
Numeric buttons illuminated.
Mute Cfg Del
1 g 7
-I z‘ :
C 9 MIA Add
a ll]
yr
Ill’ 5
III‘ 3
Numeric buttons illuminated Enter
[New pin code] (4710 digits) i» m
For example: 123123“
Lei
‘I 2 3
4 5 #
Type [Default PIN code]
(1 2 3 4 5) in. [is]
MUN lfiig [HI
1 2 3
4 5
le MIA
II D
III‘ 5
[0K] indication blinksonce.
1 long beep emitted.
Illuminated buttons turns off.
Ht'lla
Cfg [:al
PIN codes match
PIN Code doesn't match
[0K] indicatidn illuminated.
2 short beep emitted.
New PIN code is set.
Halli-J
Cfg
HI =
i ii
-. H
I 1]
iii
[Error] indication illuminated.
2 long Beeps emitted for 1 second.
ENTR“ goes to menu mode
Start the QrOEESS from stage 1.
Eel
12
ENTR® Dead Bolt User Manual
Y I ENTR‘ I
EMUL-T-LDCK'
KEVFREE .mse
3.2 Door Configuration
The door configuration process sets your lock and door preferences.
This process should be done after successful installation ofthe lock. It will take 15-20
seconds to complete.
1 ill‘ 2 ill‘ 3
Important: Verify that the door is Touch screen with palm or fingers Press [Cfg]
shut and no key is Inserted into the for 3 seconds to active
cylinder during configuration steps.
Mute Clg Del Mute Clo Del
1 2 3 l _, \‘\
4 7
Code MIA d
U [] I l]
’x// 3“, PT
4 in» 5
Numeric buttons Illuminated, Press [1] or [3] to configure ENTR”
Type [pm code] n» [u] side (see illustratioril.
1 long beep emitted. Press [1] for ENTRw on left side,
Press [3] for ENTR“ on right side.
ENTR® on left
side of the door
ENTR® on right
side of the door
Press [1] Press [3]
ENTR® Dead Bolt User Manual 13
In MUL-T-LDCK'
Hold the door shut to avoid opening.
The lock Will carry out the
configuration process.
it take's 15720 seconds to complete.
Open the door using the handle,
Bring the latch as close as possible to
the door molding,
Note: Do not shut the door.
Door
moldings
ENT
(Ewan .mss
7 Configuration OK
[Cig] Indication blinks. [Manual] indication illuminated.
Turn the knob manually to unlock [Cfg] indication blinks.
position and keep the door closed. Note: if the configuration fails
Push on [Cfg]
Magnet
refer to troubleshooting #1
d ' :
~:«:~ia rile .;..M
U [I II]
V E6? in
8 Configuration 0K
Press [Cfg] 0K] Indication blinks once.
The lock Will carry out the Zshort beeps emitted,
configuration process. illuminated buttons turn off.
iiiiie Cig Lei Mule 4;;
'I e
d e
mi; . l l
[i i l]
V/ ”N- tfli 3v? ,cff
Troubleshooting #1
Lock configuration failed
1. Remove the mechanical key from the lock.
2. Check that the door was closed properly or if
lock operation was interfered.
14
ENTR® Dead Bolt User Manual
Yum... El
m ms. us rm
Configuration failed Troubleshooting #2
[Error] indication illuminated. Magnet configuration fai|ed
2 long beeps emitted. , D4 4 .
Reiertotroubleshootin #2 1. You can still operate ENTR In Manual mode (w/o automatic locking).
2. Remove any other magnets from the door.
Hulls 1.2m pal 3. Place the magnet according to instructions.
4. Consult your installer or contact ENTRD Technical Support.
1 2 3
d 5 :
34M
[1]]
Vi
Magnet Fitting:
- Mount the magnet on the frame moldings, as close as possible to the lock.
- The lower part of the magnet should align with the lower point of the
slider (see illustration).
Frame
moldings
Slider
Magnet
ENTR® Dead Bolt User Manual 15
In MUL-T-LDCK'
I ENTR‘ I
mm; mm
3.3 Pairing Remote Control
Touch screen with palm Drfingers for
3 seconds to acnve.
Mule Clg Dal
Press [1] to add remote control.
Illuminated buttons turn off.
[ox] indication blinks for 15 Seconds,
wamng for remote control unit
Huh 1:!) [4|
1 2 5
:19
ll
// (an Kr
HI‘ 2
Press [Add]
m‘ 5
Press the remote control button,
III» 3
Numenc buttons illuminated.
Type [PIN code] \II‘ [a]
Numeric buttons blinking.
mm :12;
1 2 3
4 5 #
Remote control
button
16
ENTR® Dead Bolt User Manual
In MUL-T-LDCK'
I ENTR‘ I
mm; Inns:
Pairing 0K
Pairing failed
[0K] indication blinks once,
2 short beeps emitted.
Remote control unit addedt
llIIll—. Cfg [ =|
Notes:
[0K] indication blinks for 15 seconds,
No beeps emitted.
Start the process from stage 1.
- To add more remote control units repeat this procedure.
- A remote control unit can be paired with only one single door unit.
- It is possible to add up to 20 remote control units.
0 Only authorized dealer can reset a paired remote.
3.4 Deleting Remote Control
The deleting remote control process‘ will delete a_H remote control units including
Touchpad and Fingerprint readers defined within the system.
ul’ 3
Touch screen WIth palm orfingers for
3 seconds to active.
Mute Ciq Del
ul’ 2
Press [Del]
Numeric buttons illuminated.
Mute qu Del
4 ' #
Code MIA Add
II U [l]
\V/ in. yr
\W
\\
Type [PIN code] ul’ [#1
1 long beep emitted.
Hull» in [Vi
1 2 3
4 5 #
_ .’ is (‘l
'i
V”
ENTR® Dead Bolt User Manual
17
Y I ENTR‘ I
.MUL-T-ann'
mm; unis:
4 ”l» 5 Deletion accomplished
[Del] blinks for 30 seconds. Press [Del] to confirm. 0K] indication blinks once
2 5mm beeps emitted,
iiluminated buttons turn off.
iii-Ii» .11 ' liliila _ .1 J Del Nut—- Clg Lei
l L z | L 3 | L T,
4 ‘ :: .1 :' _z't W .1 :- :
.r 1+ IiI,—, ,..-»ii . J~ ii|... Add r. _, . ,.
H D II] !' [1 Hi \
\w H. yr y ii; yr
Note: Wall reader and smartphone connected to the ENTR® lock will not be deleted.
3.5 Setting Sound Signal
Turn the sound signal to OFF or ON
1 ill‘ 2 ill» 3
Touch screen With pairri orfirigers for Press [Mute] [Mute] indication iiluminated.
3 seconds m active. Sound signal is off.
Mule Cfg Del Mule Cfg Del Mule Gig Del
1 2 3 | ’ 3 l L 7
4 4 : :3
Code Code MIA Add
II n I 1] H l]
y Ivi VT \‘// in
Notes:
- Setting the ENTR® lock sound to OFF will mute the lock and unlock sounds, and
the open door hazard signal. It will not mute the touchpad, mechanical override
and low-battery sounds.
I Follow the same procedure to turn the sound back to ON.
18 ENTR® Dead Bolt User Manual
In MUL-T-LDCK'
3.6 Setting Locking Mode
Toggle between Automatic to Manual locking mode
ul‘ 2 III» 3
Touch screen with palm orfingers for
3 Seconds to actlve.
Press [MIA]
Mute Cfg Del
[Manual] indication illuminated.
Mute Clg Del
Code MIA Add
Ill [] ll]
Notes:
Tvpe [PIN code] ul‘ [5?]
I Setting the ENTR® lock to Manual will disable automatic locking.
0 Follow the same procedure to set the ENTR® lock to Automatic locking.
l ii’l
{nil
i-«iu Ii.
[HI
I ENTR‘ I
mm; Inns:
ENTR® Dead Bolt User Manual
19
Y I ENTR‘ I
.MUL-T-ann'
mm; mm
3.7 Doorknob Operation
Turn clockwise or counterclockwise to unlock.
Beep sound emitted during doorknob operation.
Important! When an active lock is opened by
turning of the knob you must re—operate it by
one of its automatic modes (i.e remote, phone,
sliding your fingers, touch pad etc.) or else it will
remain UNLOCKED.
Knob operation is meant solely for mechanical
override in the rare event it will not otherwise
unlock.
3.8 Slide Buttons Operation
Slide your fingers on the recessed grooves on both
sides of the ENTR® front panel:
- To open, slide fingers downwards on the recessed
grooves on both sides. /
0 To lock, slide fingers upwards on the recessed
grooves on both sides.
we
2i
2° ENTR® Dead Bolt User Manual
Y I ENTR‘ I
.MUL-T-ann' m.
4. Touchpad Reader
4.1 Mounting the Touchpad Reader
Select the location where the Touchpad Reader will be
mounted.
0 Attach the Touchpad Reader baseplate to the wall.
- Use 4 screws and screw anchors, or double sided
adhesive strip.
4.2 Battery Replacement
1. Release lid screw and open the lid.
2. Put in the batteries (ZXAA) according
to the "+" "—" signs.
3. Close the lid and tighten the screw.
Notes:
- After inserting the batteries the Touchpad
Reader will turn on automatically.
0 A short beep sound emitted and Green
[OK] indication illuminated for 2 seconds.
Important: Do not touch the Touchpad during
the self test procedure and until the lights
a re off.
4.2.1 Low Batten; Indication
When batteries need replacement, a red
warning signal will blink rapidly and long beep
will sound during every lock/unlock action.
ENTR® Dead Bolt User Manual 21

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Modify Date                     : 2016:12:28 10:54:23+08:00
Create Date                     : 2016:12:28 10:52:51+08:00
Metadata Date                   : 2016:12:28 10:54:23+08:00
Creator Tool                    : PDFCreator Version 1.2.3
Format                          : application/pdf
Title                           : ENTRR Fingerprint Reader_user manual_FCC,IC.pdf
Creator                         : suhsiao
Document ID                     : uuid:cb7c53cc-c301-43f8-8194-d4f1fac66892
Instance ID                     : uuid:7d05e16c-332b-4357-bb61-637e821368aa
Producer                        : PDF-XChange Viewer [Version: 2.0 (Build 40.7) (Nov 25 2008; 17:31:42)]
Page Count                      : 20
Author                          : suhsiao
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AHH8ENTRWRF00

Navigation menu