BR/BC Series Woodburning Fireplace Homeowner's Installation and Operating Manual For Models: BR36 BR42 BC36 BC42 WF553 For use in U.S./Canada BR/BC36 Underwriter's Laboratories Report No. MH6018 11/10/97 DO NOT DISCARD THIS MANUAL: Retain for future use. 7412944 4/07 Rev. 21 Majestic Fireplaces® BR/BC Series Safety Information PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING FIREPLACE. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Description The BR/BC Series fireplaces are solid fuel, woodburning fireplaces. The BR36/42 (Builder Radiant) is a clean-face fireplace and the BC36/42 (Builder Circulating) unit has fixed grilles. Precautions CFM Corporation fireplaces and component parts have been highly tested and will operate safely when installed in accordance with instructions provided in this manual. Carefully read and understand all instructions before beginning installation. If you notice any damage to fireplace or component parts, immediately report damage to your Majestic Fireplaces dealer. Only use CFM Corporation components or the warranty will be voided and a fire hazard may be created. CFM Corporation warranty will be voided by and CFM Corporation disclaims any responsibility for the following actions: • Installation by any other than a qualified install• • • • er, preferably NFI or WETT (Canada) certified. Installation of any damaged fireplace or chimney component; Modification of fireplace, chimney assembly or any component parts thereof; (except for chase flashings as detailed in Chimney Top installation instructions). Installation other than as instructed by CFM Corporation; or Installation and/or use of any component part not manufactured or approved by CFM Corporation in combination or assembly with a Majestic Fireplaces fireplace system, notwithstanding any independent testing laboratory or other third party approval of such component parts or accessory. Any such action may possibly cause a fire hazard. Consult local building codes to ensure that you are in compliance before installing the fireplace. Fireplaces must be vented to the out-of-doors. Do not obstruct or modify air inlets/outlets in any manner. 2 Do not install combustible materials on any of the black fireplace surround. Burn only solid wood fuel or gas logs. Do not install a solid fuel burning insert or other products not specified for use with this fireplace. Proposition 65 Warning: Fuels used in gas, woodburning or oil fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm. California Health & Safety Code Sec. 25249.6 Drafts The fireplace should not be located in areas that create drafts (ie: frequently opened doors and central heating air inlets/outlets) that hamper the normal flow of air into the fire. Gas Logs If you plan to install a gas log, the gas line should be installed before framing the fireplace. The gas line must be installed by a certified gas line installer. BR36 / BR42 BC36 / BC42 Listed UL 127 / ULC-S610 Standard for Factory Built Fireplaces Table of Contents Safety Information . . . . . . . . . . . . . . . . . . 2 Specifications and Framing . . . . . . . . . . 3 Parts Identification . . . . . . . . . . . . . . . . . 5 Chimney Requirements . . . . . . . . . . . . . 6 Planning Information . . . . . . . . . . . . . . . . 7 Installation . . . . . . . . . . . . . . . . . . . . . . . 8 Replacement Parts . . . . . . . . . . . . . . . . 19 Accessories . . . . . . . . . . . . . . . . . . . . . 20 7412944 Majestic Fireplaces® BR/BC Series BR36 Series Woodburning Fireplace 45���" (1162mm) ���" (13mm) ) m Outside Air ����" (241mm) ����" (191mm) 40���" (1035mm) ����" (191mm) Gas Line Access �����" (502mm) ��" (533mm) 36" (914mm) �����" (372mm) Gas Line Access ����" (167mm) 3" (76mm) Electrical Access �����" (337mm) 8" Dia. (203mm) ���" Recessed Nailing Flange Rough Opening Width 41" (1041mm) Rough Opening Height �� ��� " 36���" (930mm) 11" Dia. (279mm) ����" �����" (187mm) * (521mm) 20" (508mm) �� (1 �" ( 64 16 5m m m m ) ) (8 22 m �� ��� " 45���"(1162mm) ���" ��" (559mm) Rough Opening Depth 40" (1016mm) *If elbows are offset to the back of the unit, chase depth will be 22⁵⁄₈" (575mm). Fig. 1 BR36 Series specifications and framing. FP526 BR36 SPECS 10/28/98 BC36 Series Woodburning Fireplace — Circulating Model 45���" (1162mm) ���" (13mm) ��" (559mm) Rough Opening Depth 11" Dia. (279mm) 8" Dia. (203mm) ����" (187mm) * �����" (521mm) ���" Recessed Nailing Flange m Rough Opening Height Rough Opening Width 41" (1041mm) �� ���" ��� " ( ���" 16 (1 45 6m m m m ) ) 2m 82 "( ��� �� 45���" (1162mm) ) 20" (508mm) 36���" (930mm) Outside Air ����" (241mm) 40���" (1035mm) ����" (191mm) Gas Line Access ����" (191mm) 36" (914mm) �����" (372mm) �����" (337mm) 3" (76mm) Electrical Access 34���" (880mm) �����" (502mm) ��" (533mm) Gas Line Access ����" (197mm) �����" (902mm) 40" (1016mm) �����" (64mm) *If elbows are offset to the back of the unit, chase depth will be 22⁵⁄₈" (575mm). Fig. 2 BC36 Series specifications and framing. 7412944 FP527 BC36 SPECS 10/28/98 3 Majestic Fireplaces® BR/BC Series BR42 Series Woodburning Fireplace ��" (711mm) Rough Opening Depth 49" (1245mm) ���" (13mm) 11" Dia. (279mm) 17 ���" 65 (1 m 6m m m ) ) 89 5m "( �� ��� ���" Rough Opening Width 47" (1194mm) Rough Opening Height "( �� ��� 49" (1245mm) m ) ����" * �����" (187mm) (521mm) 20" (508mm) 36���" (930mm) Gas Line Access ����" (241mm) ����" (191mm) 40���" (1035mm) ����" (191mm) Outside Air 42" (1067mm) �����" (372mm) �����" Gas Line (502mm) Access ��" (533mm) ����" (197mm) 3" (76mm) Electrical Access �����" (337mm) 8" Dia. (203mm) ���" Recessed Nailing Flange 46" (1168mm) *If elbows are offset to the back of the unit, chase depth will be 22⁵⁄₈" (575mm). Fig. 3 BR42 Series specifications and framing. FP546 BR42 SPECS BC42 Series Woodburning Fireplace — Circulating Model 10/28/98 ��" (711mm) ����" * �����" (187mm) (521mm) 20" (508mm) m m (1 ���" 76 (1 5m 6m m m ) ) 89 5 ��� "( Rough Opening Width 47" (1194mm) �� ���" Rough Opening Height 11" Dia. (279mm) 8" Dia. (203mm) ���" Recessed Nailing Flange ��� " �� 49" (1245mm) ) 49" (1245mm) ���" (13mm) Rough Opening Depth 36���" (930mm) ����" (241mm) 40���" (1035mm) Outside Air ����" (191mm) Gas Line Access ����" (191mm) 42" (1067mm) �����" (372mm) �����" (337mm) 3" (76mm) Electrical Access 34���" (880mm) Gas Line Access �����" ��" (502mm) (533mm) ����" (197mm) ��" (965mm) 46" (1168mm) �����" (64mm) *If elbows are offset to the back of the unit, chase depth will be 22⁵⁄₈" (575mm). Fig. 4 BC42 Series specifications and framing. 4 FP545 BC42 SPECS 10/28/98 7412944 Majestic Fireplaces® BR/BC Series B BR/BC36 BR/BC42 C Front Width A 33¹⁄₄" (845 mm) 39¹⁄₄" (997 mm) Back Width B 19⁵⁄₈" (499 mm) 25⁵⁄₈" (651 mm) Depth C 15¹⁄₄" (387 mm) 15¹⁄₄" (387 mm) A FP1531 FP1531 Fig. 4a Hearth dimensions. hearth dimensions 9/04 djt Chase Installation Insulation methods shown are optional for cold climate, not a requirement for unit operation. Termination Cap Storm Collar Pan Flashing Batt Insulation (cut our around firestop) Draftstop Firestop Ceiling Level Standoff Surround Damper Control Nailing Flange Gas Line Knockout (both sides) Gas Line Access (both sides) Screen Grate Electrical Access Firebox Outside Air Cover Plate Metal Safety Strips (1,2 or 3 pieces) FP554 Fig. 5 Fireplace and chase parts identification. WF554 BR/BC Combo of IWF261 AND IWF265 11/10/97 7412944 5 Majestic Fireplaces® BR/BC Series Chimney Requirements - Offset Installations OFFSET CHIMNEY FLUE EXIT RISE CHIMNEY SECTION FP282 B A D E 6 FT. C G 30˚ OFFSET ELBOW RISE H OFFSET 30˚ RETURN ELBOW 30˚ RETURN ELBOW 30˚ OFFSET ELBOW B 30˚ Elbow Offsets FP282 G SKCS8 SUPPORT H HEARTH FLOOR Example 1 Example 2 Example 3 Notes: G + H cannot exceed 20 feet. Air Space Clearances: SK8 (2-wall) = 1¹⁄₂" and "S" Series (3-wall) = 2" Illustration Key FP269 The following safety rules apply to offset installations (letters correspond with illustration above): A. Height of the chimney is measured from the hearth to the chimney exit. BR/BC36 90'0" Maximum: Minimum: Without Elbows 12' 6" With 2 Elbows* 14' 6" With 4 Elbows* 21' 0" FP269 BR/BC42 90'0" 12' 6" 14' 6" 21' 0" B. Do not use more than 4 elbows per chimney. Attach the straps of the return (top) elbow to a structural framing member. The offset (first) elbow of any pair does not have straps. * In Canada, two (2) SK845 are allowed. C. The chimney cannot be more than 30˚ MBUF (45˚ in Canada) from the vertical 5/16/96 plane in rev. 5/25 any installation*. D. The maximum length of the angled run of the total chimney system is 20 feet. (G plus H cannot exceed 20 feet.) E. A chimney support (Model SKCS8) is required every 6 feet of angled run of chimney. Chimney supports are required for every 30 feet and 60 feet (SK8 pipe) or 20 feet and 40 feet (3-wall pipe) of vertical chimney height above the hearth. Determine the offset distance of your chimney arrangement from the centerline of the fireplace to the centerline of the chimney where it is to pass through the first ceiling. NOTE: This offset distance may not be your full offset distance. See Examples 2 and 3. 1' 1¹⁄₂' 3' 4' 0 1 0 2 1 0 2 0 0 1 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 0 0 0 0 0 1 0 0 1 0 0 2 0 1 2 0 1 3 0 2 3 1 2 0 1 3 0 2 3 1 2 0 1 3 0 2 3 1 2 0 0 0 0 0 0 0 0 1 0 1 1 0 1 1 0 2 1 0 2 1 0 2 1 3 2 1 3 2 1 3 2 4 3 2 4 3 2 4 3 5 Chimney Support ELBOW 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 3 3 3 3 MBUF 5/26/96 Offset Rise 3" 8¹⁄₄" 11¹⁄₄" 13¹⁄₂" 16¹⁄₂" 20¹⁄₄" 21³⁄₄" 26¹⁄₄" 28¹⁄₂" 31¹⁄₂" 34¹⁄₂" 37¹⁄₂" 41¹⁄₂" 45" 47¹⁄₄" 51" 53¹⁄₄" 56¹⁄₄" 59¹⁄₄" 62¹⁄₄" 64¹⁄₂" 68¹⁄₄" 70¹⁄₂" 74¹⁄₄" 78" 81" 84" 87" 89¹⁄₄" 93" 95¹⁄₄" 99¹⁄₄" 101¹⁄₄" 104¹⁄₄" 107¹⁄₄" 110¹⁄₄" 114" 117³⁄₄" 120" 123³⁄₄" 11" 20" 25¹⁄₄" 29¹⁄₄" 34¹⁄₄" 40³⁄₄" 43¹⁄₂" 51¹⁄₄" 55¹⁄₄" 60¹⁄₄” 65¹⁄₂" 70³⁄₄" 77³⁄₄" 83³⁄₄" 87¹⁄₂" 94" 98" 103¹⁄₄" 108¹⁄₂" 113¹⁄₂" 117¹⁄₂" 124" 128" 134¹⁄₂" 140³⁄₄" 146" 151¹⁄₄" 156¹⁄₂" 160¹⁄₄" 166³⁄₄" 170³⁄₄" 177³⁄₄" 181³⁄₄" 186¹⁄₄" 191¹⁄₂" 196³⁄₄" 203¹⁄₄" 209³⁄₄" 213¹⁄₂" 220" Fig. 6. Chimney system requirements. 6 7412944 Majestic Fireplaces® BR/BC Series Planning Information Preplanning an installation is very important to ensure safety and to save time and money. An installer must predetermine where a fireplace will be set and how the chimney system will be run. Mounting the Fireplace A fireplace may only be mounted on the following surfaces: 1. A flat combustible surface. 2. A raised wooden platform. 3. A concrete block or other solid object placed beneath each of the four (4) corners of the fireplace. The fireplace must be spaced 1/2" (13mm) from a combustible back wall and 1/2" (13mm) from a combustible side wall or support. (Page 14, Fig. 20) Planning the Chimney Run LT L1 L1 MODEL SK 2 WALL CHIMNEY SK81 SK818 SK83 SK84 TOTAL LENGTH (LT) �����" �����" �����" �����" INSTALLED LENGTH (L1) The Ten Foot Rule Major U.S. building codes specify a minimum chimney height above the roof top. The “Ten Foot Rule” is a fire safety rule and not a draft rule. To ensure proper draft, it is recommended that you always meet or exceed the “Ten Foot Rule,” especially when installing a termination on a high pitch roof. (Fig. 8) The key points of the "Ten Foot Rule" are: 1. If the horizontal distance from the chimney to the peak of the roof is 10' (3m) or less, the top of the chimney must be at least 2' (610mm) above the peak of the roof, but never less than 3' (914mm) in height above the highest point where it passes through the roof. 2. If a horizontal distance from the chimney to the peak of the roof is more than 10' (3m), a chimney height reference point is established on the surface of the roof a distance of 10' (3m) from the chimney in a horizontal plane. The top of the chimney must be at least 2' (610mm) above the reference point, but never less than 3' (914mm) in height above the highest point where it passes through the roof. �����" �����" �����" �����" 0 To 10' 2' Min. 0 To 10' 3' Min. FP288 2' Min. 3' Min. Fig. 7 Installed lengths of chimney sections. Determine how the chimney will be run, length of run FP288 and chimney components required to complete the MBUF-INSTALLED LENGTH job. (Fig. 6) Never install a chimney below minimum 6/17/96 heights. In planning a chimney system, it is important to know: 1. The height of a chimney is measured from the hearth to the exit point on the termination. 2. A chimney cannot be offset more than 30° from a vertical plane. 3. A chimney may run straight up or it may be necessary to offset it to avoid obstructions. 4. The maximum length of an angled run (total chimney system) is 20' (6 m). 5. No more than 2 offsets (4 total 30° elbows in U.S./or 2 total 45° elbows in Canada) per fireplace may be used. 6. A guy wire stabilizer is required for chimneys extending more than 6' (1.8 m) above a roof line. 7412944 Reference Point AC246 Fig. 8 Ten Foot Rule illustration. AC246 4/1/96 7 Majestic Fireplaces® BR/BC Series Installation Chimney Supports The chimney system is supported by the fireplace for vertical chimney heights less than 30' (9m) above the hearth. Chimney supports are required if the vertical height exceeds 30' (9m) with SK8 chimneys or 20' (6m) with 3-wall chimneys. Locate chimney supports at ceiling holes or other structural framing at 30' (9m) (SK8) or 20' (6m) (3-wall) heights. Spacing between chimney supports must not exceed 30' (9m) (SK8) or 20' (6m) (3-wall). Use Chimney Support Model SKCS8. (NOTE: The SKCS8 can not be mounted directly to the fireplace.) Support provided by elbow straps fulfills the support requirement only if they are spaced as previously described. (A chimney support is 2¹⁄₂" (64mm) long when installed.) Insulating Fireplace Enclosure for Cold Climates If you live in a cold climate, it is not required but highly recommended that you insulate fireplace enclosure to eliminate cold air penetration as much as possible. Insulate base of fireplace with a noncombustible insulation rated for a minimum of 300°F. Insulating is very important for outside wall installations over a concrete slab. If fireplace is installed on a platform, insulation should be placed on top of the platform before fireplace is set. (Fig. 10) A chase is a vertical box-like structure which encloses the fireplace and/or chimney. Chases are typically built on the outside of the house with fireplace opening cut into the outer wall of a room. (Page 5, Fig. 5) When a fireplace is installed in a chase or on a outside wall, enclosure should be treated like any outside wall in a home. Insulation should be installed on the inside wall as well as the outside wall(s). In a chase, it is also a good idea to install a firestop at the first ceiling level above the fireplace and enclose the chase with sheeting material. Insulation may then be installed above sheeting material to assure the space around the fireplace is totally protected. (Fig. 5) If you need help in determining fireplace location or how the chimney system should be run, contact your Majestic Fireplaces dealer for assistance. When installing the chimney, DO NOT caulk between outer pipe and firestop. It is vital that some air be allowed to flow through this very thin gap. Angled chimney runs require a support every 6' (1.8m) in addition to the elbow straps. Chimney supports are used for this function. (Fig. 9) Chase Installation CAUTION: WHEN INSTALLING A FIREPLACE IN AN INSULATED ENCLOSURE, BE SURE ALL REQUIRED AIR SPACES ARE MAINTAINED. (Page 14, Figure 20) Chimney Support Strap SKCS8 FP284 Fig. 9 Chimney support installation 8 IWF284 MBUF 5/25/96 7412944 Majestic Fireplaces® BR/BC Series Framing Option For Circulating Models Only — Framing can be constructed before or after the fireplace is set in place, however, most installers build the frame before setting the fireplace. Frame fireplace with 2 x 4 lumber or heavier materials. Refer to framing dimensions in Figures 1, 2, 3 or 4 for basic fireplace specifications. NOTE: When using 2 x 6 framing construction, the allowable air space between the front of the SK8 outer pipe and 2 x 6 framing is reduced to 1" (25mm) as tested and approved by U.L. for use in both the United States and Canada. NOTE: Framing should be positioned to accommodate wall covering and fireplace facing material. Installing Electrical Wire (for Circulator Models) If a circulating fireplace is to be installed, run the 120 VAC, 60 Hz wiring to the left side of installation. Wiring must be completed before the fireplace is secured and finish material applied. EB1 (Receptacle) Hook-Up: • Wiring should be installed by a certified electrician. • Turn off circuit breaker before wiring models. Once fireplace is secured, complete wiring the fan kit. Remove knockout in the center of the back of the EB1 and install listed cable clamps. Feed electrical wire through listed cable clamp leaving approximately 6" (152 mm) of wire exposed through the EB1. Secure listed cable clamp to the wire. Attach white wire from power source to one (1) wire of receptacle and secure with nut. Attach black wire from power source to the other wire of receptacle and secure with nut. Be sure nuts are secured tightly. Secure EB1 assembly to inside of electrical box coverplate using two screws. Attach cover to face of the EB1 while being careful to position excess wire completely within the EB1, then attach coverplate to fireplace. Install Fan Kit Assembly Remove the cover plate and electrical knock-out on the lower left side of the fireplace and set aside. Follow the instructions on Page 10 for proper wiring and installation of the EB1. Refer to optional Model FK12 fan kit assembly installation instructions for field installation. If the fan kit is not being installed with the fireplace, it is highly recommended that 120 VAC supply be made available since someone may elect to install a blower at a later date. Chimney Set-up Hard Flat Surface Since you have already preplanned the chimney run, you should know exactly how the installation is to be accomplished — how much pipe is required, the number of elbows, if any, and type of termination to be used. CAUTION: REPORT TO YOUR DEALERS ANY PARTS DAMAGED IN SHIPMENT, SPECIFICALLY CHECK THE END CONNECTION OF CHIMNEY SECTIONS AND ELBOWS. NOTE: Fireplaces may use CFM Corporation Model SK8, or Model S (three wall) chimney systems. The BR/BC Series Fireplace will accept the SK8 chimney system as is; but a TWABR adapter collar is required when using the Model S (triple wall) chimney system. The installation procedure described in this manual applies only to the SK8 system. Either chimney system may be used, but may not be mixed. Insulation Platform FP555 Fig. 10 Insulating between platform and fireplace. 7412944 9 FP555 Platform, insulation 1/10/97 Majestic Fireplaces® BR/BC Series Straight-Up Chimney Installation To mark the centerline of the flue, put the fireplace in final position and measure out from the wall: 8¹⁄₄" (210 mm) Mark a spot on the ceiling directly above the fireplace. Draw a line parallel to the back wall through this mark. (Fig. 11) Using a plumb bob positioned directly over center point of fireplace flue collar, mark the ceiling to establish the chimney center point. (Fig. 11) Chimney Centerline Determine offset distance of your chimney arrangement from centerline of fireplace to centerline of chimney where it is to pass through ceiling. Locate center point of the chimney on ceiling as though a straight up chimney arrangement is to be used. Measure your offset dimension from straight up chimney center point on ceiling. Ceiling Chimney Hole/ Possible Obstructions The size of the hole in ceiling will vary with the angle at which the chimney passes through ceiling. Drive a nail up through ceiling at marked chimney center point. Go to floor above and see where hole will be cut. Check to see where existing ceiling joists and other possible obstructions are located...i.e. wiring, plumbing etc... If necessary, re-position chimney and/or fireplace to avoid obstructions. Actual Centerpoint ����" (210mm) Cutting the Hole Cover fireplace collar opening and cut proper sized chimney hole in chimney. The SK8 pipe allows you to run pipe through a typical 16” on center joist without cutting joists. Plumb Line Framing the Ceiling Hole Plumb Bob Frame the ceiling chimney hole as shown in Figure 12. It is good practice to use framing lumber that is the same size as the ceiling joists; this is a requirement at attic level. Imaginary Centerpoint Existing Ceiling Joists AB AB Chimney Hole FP556 Fig. 11 Locate centerline of chimney with plumb line. Offset Installation In order to clear an obstruction, it may be necessary to offset chimney from vertical. This is accomplished by using CFM Corporation elbows. Use the 30° Offset Elbow table on Page 6 to determine proper offset and parts required. FP556 Each offset requires two (2) elbows. The second elbow BR/BC is equipped with support straps. ItLOCATE is very CENTER importantLINE to install the second elbow in each offset as close to the 11/10/97 ceiling or support as possible so that the elbow straps can be secured to framing members to help support the weight of the chimney. 10 Ceiling New Framing Members A "SK" Series framing = 14¹⁄₂" X 14¹⁄₂" (368 x 368mm) B "S" Series framing = 17¹⁄₂" X 17¹⁄₂" (445 x 445mm) FP551 Fig. 12 Typical frame for ceiling chimney hole. FP551 BR/BC 9/29/97 7412944 Majestic Fireplaces® BR/BC Series The following table gives firestop spacer model numbers: Angle of Chimney at Ceiling Size of Chimney Vertical 30° 8" Flue SKFS2A SKFS6A "SK" Series 14¹⁄₂" x 14¹⁄₂" 14¹⁄₂" x 25¹⁄₂" (368 mm x 368 mm) (368 mm x 648 mm) 8" Flue FS2A FS6A "S" Series 3-Wall 17¹⁄₂" x 17¹⁄₂" 17⁷⁄₈" x 29⁵⁄₈" (445 mm x 445 mm) (454 mm x 753 mm) Installing Outside Air Kit An outside air kit is installed in all BR/BC Series Fireplaces. If desired, or if local codes mandate the use of an air kit, then an AK-MST is required to complete the installation (from air kit to the outdoors). If the outside air kit is to be used, the AK-MST MUST be installed BEFORE the fireplace is enclosed. Refer to the AK-MST instructions for field installation. Fig. 13 Ceiling chimney hole sizes necessary for installing firestop spacer. The inside dimension of the frame must be the same as the hole size selected from Figure 13 in order to provide the required 1¹⁄₂" (38 mm) of air space between the outside diameter of the chimney and the edges of the framed ceiling hole. Metal Safety Strip (1,2 or 3 pieces) Positioning, Safety Strips, Securing the Fireplace FirePlace Slide fireplace into position. Lift the fireplace front slightly and slide the metal safety strips under front bottom edge about 1¹⁄₂" (38 mm), allowing the remainder to extend in front of firebox. Overlap strips at least 1/2" (13 mm) to provide a positive joint. (Flat safety strips are packed with fireplace.) (Fig. 14) ����" (38mm) ���" (13mm) Min. Overlap (not supplied) PlatForm FP557 WF557 BR 11/10/97 Nail Top Standoffs If fireplace is to be elevated above the floor, a “Z” shaped metal safety strip must be fabricated and used to protect combustible surfaces in front of the fireplace. This “Z” shaped safety strip is not provided but must be fabricated of metal with each horizontal leg at least 1¹⁄₂" (38mm) wide and equal in length to the metals strips provided with the fireplace. Four (4) nailing flanges are supplied with the fireplace (found on the fireplace hearth). To level the box and secure it firmly in place, remove the nailing flanges from the hearth and install at the sides of the fireplace as shown in Figure 15. 7412944 Hearth Ext. Fig. 14 Safety strip installation. Safety strips are used to ensure that any combustible materials in front of the fireplace are protected even though a noncombustible hearth extension is required. Note: Safety strips are not required over noncombustible floors where all supports at the base of the fireplace are noncombustible. "Z" Safety Strip Nail SideNailing Flanges FP549 Fig. 15 Fasten fireplace in position. FP549 9/29/97 BR/BC 11 Majestic Fireplaces® BR/BC Series Installing the Chimney System Pipe Section Start by attaching the first chimney section to the collar on top of the fireplace. Pipe Rim UP Install the pipe as pictured in Figure 16. When you get a good lock, you will hear the pipe clearly snap together. Once sections are snap-locked in place, it is extremely difficult to get them apart. Make sure the pipe is firmly snapped and locked together as each pipe section is mounted. Pipe Rim Hem Lance When installing elbows, only outer pipe will snap- lock. Middle pipes simply slide into position. Be sure to always attach straps on upper elbow to a structural framing member. (Fig. 17) Continue installing the pipe as required until pipe is installed up through the ceiling. At this point, you must install a firestop spacer. Installing the Firestop Spacer in the Ceiling Hole FP558 Fig. 16 Install pipe, listening for the snap-lock to fasten. Support Structure A firestop spacer is used to keep pipe spaced properly and required for safety. Nail the firestop spacer (at each corner) to the framing members of the ceiling hole. NOTE: A firestop spacer is not required at the roof. Hole sizes listed in Figure 13 for angled firestop spacers provide minimum required air space to chimney pipe for ceiling thickness up to 8" (203mm). When combined thickness of ceiling material, ceiling joists and flooring material exceeds 8" (203mm), adjustments must be made in framing to assure that minimum air spaces to chimney are maintained. FP558 BR 11/10/97 If the area above the ceiling is not an attic, position the firestop spacer with the flange on the ceiling side and the angled portion extending up into the hole. If the area above the ceiling is an attic, position the firestop spacer with the flange on the top of the framed hole and the angled portion extending down into the hole. Ceiling Hole Framing Elbow Strap Angled Firestop Proper Firestop Spacer Installation Figure 18 shows different installation procedures for both an area that is an attic and an area that is not an attic. Elbow Strap (must be tight) Angled Strap Chimney Support Strap (must be tight) FP270/271 FP270/271 CR Series Fig. 17 Attach straps to a structural framing 2/19/99 member. djt Ceiling Installation Attic Installation Nails (4) Joist Firestop Spacer Firestop Spacer Joist Nails (4) NOTE: If the attic insulation shield is used, the firestop is not required in the attic installation. FP593 Fig. 18 Installing firestop spacer. 12 FP593 SR/C 11/20/97 7412944 Majestic Fireplaces® BR/BC Series Firestop spacers are not available for nor are they required on vertical walls. DO NOT put any sealant around the area where the outer pipe slides through the firestop spacer. If you seal this area, it may cause a fire hazard. A chimney support is 2¹⁄₂" (64mm) long when installed. Consider this dimension when determining how many straight chimney sections are needed. NOTE: Chimney supports are generally used in long runs in a chase installation. Additional Ceilings Canadian Requirements for Insulation Shield In Canada, an attic insulation shield is required to prevent attic insulation from contacting the chimney section. NOTE: If the attic insulation shield is used, the firestop is not required in the attic installation. Framing dimensions for the chimney hole should measure 14¹⁄₂" x 14¹⁄₂" (368 x 368mm). An attic shield MUST be installed on top of attic joists (above the floor level). (Fig. 19) NOTE: In the U.S., it is a good idea, although not always required, to install an attic insulation shield where blown-in insulation is planned to be used in the attic. Install the attic insulation shield with the flanges on its base extending down into the framing hole. Nail each corner of attic insulation shield to the framing members of the ceiling hole using 8d nails. Attic shields are not required at the roof. If you encounter additional ceilings, repeat same steps required for first ceiling installation. See firestop illustration on Page 12, Figure 18. Penetrating the Roof Run pipe to roofline. Since chimney system must be vented to the out-of-doors, you must use an approved termination. If a chase is used, refer to the installation manual provided with the termination cap. Locate Chimney Centerpoint On Roof Use same procedure detailed in locating center point of the flue system. Drive a nail up through roof at the center point. This will determine center point on outside of the roof. Cut and Frame Roof Hole Size of roof hole varies with the type of chimney termination installed. Refer to installation instructions provided with the chimney termination to find correct size of roof hole. Attic Insulation Shield Nails (4 required) Attic Joist Ceiling Base Flanges FP263 Fig. 19 Attic shield installlation (Canadian requirement). Continue Installing Pipe to Complete Run FP263 MBUF Continue attaching pipe sections to complete system to next level always being careful that the 5/9/96 pipe is firmly snapped locked in place before proceeding to next pipe section. Chimney Supports There must be a 1¹⁄₂" (38mm) air space between outermost portion of chimney sections and any adjacent combustible surfaces. (Combustible surfaces include burnable materials such as: ceiling members, joists, flooring, combustible insulation and roof structures.) WARNING: DO NOT PACK REQUIRED AIR SPACES WITH INSULATION OR OTHER MATERIALS. Mark an outline of the roof hole around the center of the point nail. NOTE: Hole dimensions given in the chimney top installation instructions are horizontal dimensions; therefore, the hole size must be marked on the roof accordingly. Cover the opening of the installed chimney so debris cannot get into the system. Cut and frame the hole. It is good practice to use framing lumber that is the same size as the rafters. Install the frame securely because the chimney top and flashing anchored to the frame must be able to withstand heavy winds. If chimney supports are required, they are installed the same as elbows. Nail chimney support straps to adjacent structural framing, as shown on Figure 9, Page 8. Bend straps as necessary and make sure they are secure so they will support the weight of the chimney. 7412944 13 Majestic Fireplaces® BR/BC Series Install Remainder of Chimney Sections Since you have already preplanned the height of your termination according to the Ten Foot Rule, continue to install pipe to the predetermined height. Air Space Clearances Combustible framing material MUST NOT penetrate AIR SPACE (shaded areas). Check the chimney top installation instructions for details on how high above the roof top the chimney sections (all pipes) should extend. Installing Top Housing or Termination Follow the installation instructions provided with the chimney termination you have selected. Installing Chimney In a Chase Refer to Page 5, Figure 5 for an illustration of a typical chase installation. CAUTION: Treatment of firestop spacers and construction of chase may vary with type of building. These instructions are not a substitute for local building codes. You must check your local building codes to determine specific requirements for your city or state. NOTE: Other building materials may be required in addition to Firestop Spacers. 1���" (SK8) 2" (3-WALL) Standoff ���" air space to sides Front View Side View Firestop Wall Shield 1/2" (13 mm) Air Space to Back Finishing 1/2" (13 mm) Air Space to Sides CAUTION: All joints between the finished wall and the fireplace surround (top/sides) must be sealed with noncombustible material to prevent cold air leakage into the room. Only noncombustible material may be applied to the facing of the fireplace surround. (Black painted area) (Fig. 20) Finish Wall Finish the wall with material of your choice. Do not install a combustible mantel shelf less than 12" (305mm) from the top of the fireplace opening for radiant models and 12" (305mm) from top of grille opening for circulating models. Do not install a mantel face plate less than 6" (159mm) from top of fireplace opening for radiant models and 6" (159mm) from top of grille opening for circulating models. (Fig. 22) If a combustible material is used below a flat mantel shelf, consult your local building codes for minimum clearance from top of fireplace opening to bottom of mantel shelf. Only noncombustible material may be applied as facing to the black fireplace surround. 0" Clearance to Floor Hearth Extension FP559 Fig. 20 Minimum clearances to combustibles. Often a decorative surround or vertical portion of the FP559 mantel is desired. If this is constructed of any combusBR/BC tible material it must be within the safe zone indicated in AIR SPACES Figure 23. 11/10/97 All joints (top, bottom and sides) where wall or decorative facing material meets fireplace surround must be completely sealed with a noncombustible material. (Figures 21 and 22) NOTE: No side wall protection is required for fireplaces installed at 45° to two (2) side walls (corner installation). 14 7412944 Majestic Fireplaces® BR/BC Series Mantel Clearance - Radiant Model - No Noncombustible Facing Material Combustible Mantel and Trim 12" (305mm) Max. Finished Wall 1���" (38mm) Combustible Mantel and Trim 12" (305mm) Max. Standoff Noncombustible Material 12" (305mm) Min. Radiant Surround Face Mantel Clearance Circulating Model Combustible Mantel and Trim Finished Wall 1���" (38mm) Header 12" (305mm) Min. * Mantel Clearance - Radiant Model - with Noncombustible Facing Material 1���" (38mm) Header Standoff 6" (159mm) Min. 12" (305mm) Max. Noncombustible Material Noncombustible Facing Material Radiant Surround Face 12" (305mm) Min. 6" (159mm) Min. Header Standoff Noncombustible Material Circulating Surround Face Fireplace Opening Fireplace Opening Fireplace Opening Finished Wall * Minimum width from top of surround to bottom of screen rail Top View ���" 2 x 4 Stud Finished Wall Fireplace Front Must be sealed with noncombustible material FP531a Fig. 21 Mantel clearances. Face Plate FP531a BR/BC mantel clearances 9/03 djt 1¹⁄₂" Ref. *12" from top of fireplace opening for radiant models 12" from top of grille opening for circulating models **6" from top of fireplace opening for radiant models (Noncombustible material must seperate the black face surround of the fireplace from any combustible mantel material) 6" from top of grille opening for circulating models * ** Combustible materials are permitted within a shaded area shown in Figure 23 titled Minimum Wall Clearances. MA81 Fig. 22 Combustible mantel clearances. 7412944 MA81 rev. 8/5/97 15 Majestic Fireplaces® BR/BC Series Side Wall Protection Hearth Installation Adjacent combustible side walls that are within minimum dimensions shown in Figure 23 of the fireplace opening must be protected with CFM Corporation Wall Shield Model SP40 or a specifically built wall shield described in Figure 20. A hearth extension is required to protect a combustible floor in front of the fireplace. Refer to Figure 23 for minimum dimensions and mounting detail. The special wall shield design described in Figure 20 is an alternate method of adding protection to side walls and can be used in place of the SP40 with the same wall clearances specified for the SP40. Rt must =1.85 minimum. The hearth extension described in Figure 23 must be a durable noncombustible material with a minimum (total) Rt value of 1.09; see Figure 24 for examples. The overall height (above a combustible floor), depth and width must be as indicated, with the extension centered to the fireplace opening. Examples of wall shield insulation: 1. Manville - CERAFORM 126, K=.27, 1/2 inches thick NOTE: Hearth Extension must not cover the air inlet opening of a fireplace. The top of insulation must be covered with a noncombustible decorative covering or a piece of .018” minimum sheet metal, to protect hearth extension material. (Fig. 23) 2. CFM Corporation - EH2416, K = .458, 1 inch thick required. Secure the hearth extension to the floor to prevent shifting, using trim molding or other similar means at three (3) outer edges. Seal crack between the fireplace hearth and hearth extension with a noncombustible material. (Figs. 23 and 25) Minimum Hearth Extension Dimensions Minimum Wall Clearances WITH Noncombustible Surround Facing WITHOUT Noncombustible Surround Facing Shaded area starts 1/2" away from edge of unit 4" 4" Brick (Example material) E C** Side Wall (for On-Site Construction) Firebox Opening F** E D A - Min. clearance to combustible perpendicular wall Side B - Min. clearance Wall to combustible perpendicular wall when using noncombustible wall shield* Combustible material permitted within shaded area. * Noncombustible wall shield requires 1" CFM Corporation EH2416 insulation (minimum R Value = 1.85) between decorative noncombustible rigid covering and combustible wall. Minimum height and width is 40" x 40". ** Dimension/degree of angle will vary depending on thickness of noncombustible surround facing. A B 16" 12" 406 mm 305 mm BR/BC42 20" 12" 508 mm 305 mm BR/BC36 C 48° 42° H G G J May install noncombustible decorative covering OR .018" min. sheet metal Seal cracks between the fireplace and hearth extension with noncombustible material Fireplace Hearth 4" MIN. Combustible Floor Minimum Insulation Value "R" Safety strips must overlap ���" minimum D 41° E F G H J 18" 14" 9" 16" 48" 457 mm 356 mm 229 mm 406 mm 1219 mm 35° 18" 14" 12" 20" 61¹⁄₂" 457 mm 356 mm 305 mm 508 mm 1562 mm Fig. 23 Combustible side wall protection and hearth extension dimensions. FP594 SR/SC 16 11/20/97 FP594 7412944 Majestic Fireplaces® BR/BC Series WARNING: HEARTH EXTENSION MUST BE INSTALLED IN ACCORDANCE WITH FIGURE 23 AND MUST NOT COVER THE BOTTOM FRONT OPENING OF THE CIRCULATING MODEL. Example of Determining Hearth Extension Equivalents Alternate noncombustible materials may be used providing the (total) thermal resistance (Rt value) of the alternate material employed is greater than or equal to R = 1.09 Thermal resistance (R) or thermal conductivity (K), may be obtained from manufacturer of the material. Factors are related by the formula K = 1/R. (Fig. 24) NEW K of new material (per inch) thickness required = --------------------------------------- X of listed thickness K of listed material (per inch) material T = given thickness R = thermal resistance for a given thickness (T) K = thermal conductivity Noncombustible material with a lower R value may be used, provided thickness of material is sufficiently greater to maintain an equivalent (total) thermal resistance (Rt). COMMON MATERIALS AND FACTORS MATERIAL EH2416 K* (CFM Corporation) MINIMUM THICKNESS R 0.458 1.09 Common Brick 5.0 0.10 To determine the thickness required for any new material: Example for Common Brick T (new) = 5.0/0.458 x 0.50 in. = 5.46 in. (new required thickness). Recessed Installation - BR/BC36 Only Noncombustible Material (if desired) Insulation with Minimum R Value of 2.75 0.50 in.** Minimum 33” (838 mm) 2” (51 mm) 2” (51 mm) Hearth Extension A FP533ADD Minimum .030 Thick Stainless Steel Plate Fig. 24 Hearth extension material factors. Noncombustible Decorative Facing 6” (152 mm) Minimum 5.46 in.** R Value is for 1/2 inch. * Units of K = BTU/SQ FT/HR/˚F/IN ** Thickness of Listed Material Wall Covering Minimum 36” (914 mm) A FP533ADD Addendum 6/1/99 djt 2x4" HEADER 8/4/99 changed .2 .1 notch at Dotonot one inch to 1/2 inch djt standoffs. Seal all cracks between fireplace surround and wall materials with noncombustible material. Insulation with Minimum R Value of 2.75 Minimum .030 Thick Stainless Steel Plate Maximum 10” (254 mm) Maximum 14” (356 mm) Noncombustible Decorative Covering Hearth Extension FP1608 View A Hearth Extension Insulation Seal crack between fireplace and hearth extension with noncombustible material. Side View Safety Strips Must be overlapped ���" minimum. FP550 Fig. 25 Sealing gaps. 7412944 NOTE: If noncombustible material is not used between the stainless steel plate and fireplace opening, the steel must be attached to the front of the unit a minimum of four (4) places on each piece with sheet metal screws no longer than 1/2". ������ NOTE: The size of the insulation and stainless steel plate must be within������������������� limits stated above and covers all combustible framing material. ���� Fig. 26 Recessed installation. FP550 BR/BC - SEALING DETAILS 29/97 17 Majestic Fireplaces® BR/BC Series Installing Line For Gas Log CFM Corporation fireplaces are designed to accept a 1/2 inch gas line for installation of an approved gas appliance. (CFM Corporation manufactures a wide variety of gas logs for use in CFM Corporation fireplaces.) Be sure to have the appliance installed in accordance with building codes. Gas connection may enter from either left or right side of the fireplace. Fireplace Top View Hole in Outer Casing Gas Line Tube 1" Min. Supply Line Ceramic Knockout Repack Insulation 1/2" Locate appropriate gas line in the outer casing of fireplace and remove insulation from gas line tube. (Fig. 27) From inside the fireplace, locate the knockout on the firebrick -- be sure you are on the appropriate or "gas line" side of the fireplace. Using a flat bladed screwdriver or small chisel and hammer, carefully tap around the knockout until it loosens and falls out. Install 1/2 inch certified gas pipe through opening. After gas pipe installation is complete, use insulation that was removed from gas line tube to repack space around the pipe. Material should be inserted from outside of the fireplace and packed tightly to totally seal between the pipe and tube. Note: Gas pipe should not come in contact with any wood structures until it has reached a point at least one (1) inch away from fireplace side. NOTE: When installing an ANSI Z21.11.2 ventless appliance, the finishing material used for the mantel must be rated at 250°F or greater. BTU input of a gas appliance installed in fireplace should be rated less than 100,000 BTU/Hr. Gas pipe installation is intended for connection to a decorative gas appliance only when (1.) incorporating an automatic shutoff device and (2.) complying with the Standard for Decorative Gas Appliances for Installation in Vented Fireplaces (ANSI Z21.60) or CSA draft requirements for Gas-Fired Log Lighters for Woodburning Fireplaces (Draft No. 4, August 1993). Hole in Outer Casing Ceramic Knockout (both sides) FP560 Fig. 27 Gas line access. WF560 BR/BC CAUTION: WHEN USING DECORATIVE 11/10/97 MUST GAS APPLIANCE, FLUE DAMPER BE SET IN FULLY OPEN POSITION. IF YOU HAVE GLASS DOORS ON THE FIREPLACE, THEY MUST ALSO BE FULLY OPENED. WARNING: DO NOT OPERATE AN UNVENTED GAS LOG SET IN THIS FIREPLACE WITH THE CHIMNEY REMOVED. WARNING: WHEN INSTALLING AN UNVENTED GAS LOG SET, THE CFM CORPORATION MODEL AH3244BK OR AH3244PB 4" ADJUSTABLE HOOD MUST BE USED. Decorative gas appliance should be installed in accordance with the National Fuel Gas Code, ANSI Z223.1/ NFPA 54 (latest edition). Only unvented gas log sets which have been found to comply with the Standard for Unvented Room Heaters, ANSI Z21.11.2, are to be installed in this fireplace. 18 7412944 Majestic Fireplaces® BR/BC Series 1 10 2 b 4 6 c d 3 a 5 8 12 13 7 9 11 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, with out notice. BR/BC SERIES For units: FA40R0, FA40R1, GA40R0, GA40R1 1. 2. 3. 4. 5. 6a. 6b. 6c. 6d. 7. 8. 9. 10. 11. 12. 13. Item/Model Number Damper Blade Weld Assembly Damper Bracket Screen Rod Assembly Screen Assembly (two per fireplace) Screen Pulls Firebrick - Hearth* Firebrick - Rear* Firebrick - Rt. Side* Firebrick - Lt. Side* Top Brick Retainers (three per fireplace) Cable Clips (four per fireplace) Hearth Pan Cover (BC Only) Outer Collar Assembly (SK8 Chimney) Nailing Flange - Bag of 4 w/screws Basket Grate O.S.A. Assy. BR/BC36 RP199 944 3030176 BR/BC parts 3030126 5/16/00 djt 7554338 7554239 3030103 or 20007494 3030102 or 20007495 3030160 or 20007492 3030104 or 20007493 3030172 7512135 3031104 3030143 2253160 3030129 20003076 BR/BC42 RP199 3030176 3032112 7554340 7554239 3032103 or 20007496 3032102 or 20007497 3030160 or 20007492 3030104 or 20007493 3030172 7512135 3031104 3030143 2253160 3030129 20003076 * When ordering replacement firebrick, check the serial number and plant code of the fireplace, located on the UL label inside the firebox. Serial numbers/plant code with an 'H' require the firebrick listed first under the respective fireplace (white brick). Serial numbers/plant code with an 'X' require the firebrick listed second under the respective fireplace (grey brick). 7412944 19 Majestic Fireplaces® BR/BC Series Accessories The following accessories for this appliance are available from your local Majestic Fireplaces distributor. Should you need additional information beyond what your distributor can furnish, contact: CFM Corporation, 410 Admiral Blvd., Mississauga, Ontario, Canada L5T 2N6, Attn: Technical Services. CAUTION: This fireplace and chimney assembly is a highly engineered system, and, as such, must be operated only with CFM Corporation approved components. If you use an unapproved component to make any modifications, you may create a possible fire hazard and will void the CFM Corporation warranty. In addition, such action may void the coverage provided by the owner’s insurance. Description Accessory Glass Door — Standard Bi-Fold door set Brushed Brass finish 42GDKBB (BR/BC42) Black finish Polished Brass finish Pewter finish Fan Kit Variable Speed Control Outside Air Termination Hearth Extension Insulation Grate for BR/BC36/42 Hearth Patch Compound Chimney System Adapter Collar Provides forced air flow Provides speed adjustment of fans Completes connection from air kit to out-of-doors Provides hearth extension floor protection Holds firewood in firebox Patch cracks in hearth Converts fireplace to a 3-wall chimney system Model Number 36GDKBB (BR/BC36) 36GDKBK (BR/BC36) 42GDKBK (BR/BC42) 36GDKDP (BR/BC36) 42GDKDP (BR/BC42) 36GDKS (BR/BC36) 42GDKS (BR/BC42) FK12 SCVS AK-MST EH2416 RBBG36 HPC-1 TWABR Contact your Majestic Fireplaces distributor or dealer for finishing Marble and Mantels, available in a wide selection of styles. 20 7412944 Majestic Fireplaces® BR/BC Series Chimney Components U.S. Component Round Top Termination Round Top Termination Extended Flashing Square Termination Housing Adapter Kit Housing Extensions Square Chase Termination Adapter Kit Chase Top Housing Chase Top Housing SK8 Chimney Sections SK8 Chimney Elbows Firestop Chimney Support 7412944 Description Top used to terminate chimney at roof. (Flashing not included.) Top used to terminate chimney at chase. (Flashing not included.) Metal finishing required around Contemporary Termination to prevent rain leakage. Top housing of simulated brick pattern available in red, tan or white. Appropriate adapter required. Flashing included. Unites Square Termination with chimney pipe (required). Extends Square Termination on steep pitched roofs. Housing used to terminate chimney through a chase top. Appropriate adapter required. (Flashing not included.) Unites Square Chase Termination with chimney pipe (required). Low profile pyramid-style chimney cap used to terminate chimney through a chase. Includes adapter. (Flashing not included.) Square chimney cap used to terminate chimney through a chase. Terra Cotta Masonry. Includes adapter. (Flashing not included.) Pipe used to build 8" (SK8) flue systems. Elbow used to create an offset in an 8" chimney system. Only 30˚ elbows available. Packaged 2 per carton (offset and return). Required at each floor level of chimney installation. (Plus attic on multi-story installation.) Used to support chimney for each of: 30' vertical height and 6' of angled chimney run. Model Number RLTSK8 RLTSK8L 8-6-12 with 8" flue: 0-6/12 pitch 8-12-12 with 8" flue: 6/12-12/12 pitch S20B (R,T,W) Msut include PLTSK8 or SLTSK8 CF8CA 202036 CT100 CTSK PTLSK8 SLTSK8 SK81 (1' Long) SK818 (1¹⁄₂' Long) SK83 (3' Long) SK84 (4' Long) SK830-2 SKFS2A — (8" straight flue) SKFS6A — (8" 30˚ inclined flue) SKCS8 21 Majestic Fireplaces® BR/BC Series (Chimney Components con't.) Canada Component Chimney Collar Enclosure Attic Insulation Shield SK8 Chimney Sections 45˚ Chimney Elbows 22 Description Installs on the "over the chimney collar" of the fireplace; provides outside air to assist in cooling the chimney system. Used to prevent insulation from coming in contact with the chimney system. Used to build chimney systems exposed above roof. Provides 45˚ offset and return. For Canadian installations only. For use with SK8 chimney only. (Maximum use of 2, or 1 pair.) Model Number CCE-SK AIS-SK SK818CAN (1¹⁄₂' Long) SK84CAN (4' Long) SK845/2 7412944 Majestic Fireplaces® BR/BC Series LIMITED WARRANTY & 30 YEAR PROTECTION PLAN For MAJESTIC FIREPLACES® PRE-ENGINEERED Fireplace Systems CFM Corporation warrants its MAJESTIC FIREPLACES® PreEngineered Fireplace (“Fireplace”) and the CFM Corporation supplied firegrate, glass doors, outside air system, fan motor, and liners to be free from defects in material or workmanship, as follows: A. Fireplace and Chimney Components: (exclusive of CFM Corporation-supplied firegrate, glass doors, outside air system, fan motor, and liners all of which are covered by separate warranties under paragraphs B through D below): At its option for a period of thirty (30) years from the date the Fireplace is installed, CFM Corporation will; 1. For a period of five (5) years from the date the Fireplace is installed, CFM Corporation, at its option, will repair or replace any defective part without charge. 2. Thereafter, through the 10th year after the date the Fireplace is installed, if replacement parts are available, CFM Corporation will provide a replacement for any defective part without charge for the part itself. The consumer must pay for everything else other than the part. 3. Thereafter, through the 30th year after the date the Fireplace is installed, if replacement parts are available,CFM Corporation will provide a replacement for any defective part at a cost to the consumer of CFM Corporation then current list price, FOB CFM Corporation factory. B. Firegrate, Glass Doors, Outside Air System: For a period of 90 days from the date the Fireplace is installed CFM Corporation, at its option, will provide a replacement for any defective part, without charge for the part itself, FOB CFM Corporation factory, (The consumer must pay for everything else other than the part,). C. Fan Motor: 1. For a period of one (1) year from the date the Fireplace is installed, CFM Corporation, at its option, will repair or replace any defective part without charge. 2. Thereafter, through the 30th year after the date the Fireplace is installed CFM Corporation, at its option, if replacement parts are available, will provide a replacement for any defective part at a cost to the consumer of CFM Corporation then current list price, FOB CFM Corporation factory. D. Liners (Refractory or Metal): 1. For a period of two (2) years from the date the Fireplace is installed, CFM Corporation, at its option, will repair or replace any defective part without charge. 2. Thereafter, through the 30th year after the date the Fireplace is installed CFM Corporation, if replacement parts are available, will provide a replacement for any defective part at a cost to the consumer of CFM Corporation then current list price, FOB CFM Corporation factory. This warranty is subject to the following conditions and limitations: 1. This warranty is extended only to a Fireplace installed in the continental United States, the state of Alaska and Canada; only if and so long as the Fireplace is installed or serviced by a qualified installer, preferably NFI or WETT (Canada) certified, and according to the installation instructions furnished with 7412944 the Fireplace, and operated at all times under normal conditions, use and service according to the operative instructions furnished with the Fireplace, and only if and so long as the Fireplace is not removed from its original installation. 2. This warranty is non-transferrable, and is made to the original owner, provided that the purchase was made through an authorized supplier of the Company. 3. The sole and exclusive remedies for breach of any warranties hereunder shall be for the repair, replacement or provision of a replacement part at CFM Corporation then current list price, FOB CFM Corporation factory, for any defective part as specified in paragraphs A through D. 4. CFM Corporation shall not be liable for damage from any smoking of a MAJESTIC FIREPLACES Pre-Engineered Fireplace System related to environmental geographic conditions (such as, for example, nearby structures or roof peaks, trees, hills, or mountains), inadequate ventilation, or negative air pressure in the place where the Fireplace system is installed, related to any mechanical system (such as, for example, furnaces, fans, air conditioners, clothes dryers, etc.) 5. Except as otherwise expressly specified in paragraphs A through D, NONE OF THESE WARRANTIES COVER, AND CFM CORPORATION SHALL NOT BE RESPONSIBLE FOR, ANY CONSTRUCTION, INSTALLATION, LABOR, TRANSPORTATION OR OTHER COSTS OR EXPENSES ARISING FROM A DEFECTIVE PART, ITS REPAIR OR REPLACEMENT OR OTHERWISE, NOR SHALL CFM CORPORATION IN ANY EVENT BE RESPONSIBLE FOR ANY INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES EXCEPT TO THE EXTENT REQUIRED BY LAW. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this exclusion or limitation may not apply to you. NO IMPLIED WARRANTIES, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL REMAIN IN EFFECT AFTER THE EXPIRATION OF THE WARRANTIES SET FORTH IN PARAGRAPHS A THROUGH D. Some states do not allow limitations on how long an implied warranty lasts, so this limitation may not apply to you. In order to obtain performance of any of the above warranty obligations write to CFM Corporation at this address: CFM Corporation 410 Admiral Blvd. Mississauga, Ontario, Canada L5T 2N6 Attention: Director of Warranty Services Since local building requirements may vary greatly throughout the country, users of CFM Corporation products should determine in advance whether there are any building code restrictions on the use of a specific product. CFM CORPORATION MAKES NO REPRESENTATION OR WARRANTY REGARDING, AND SHALL NOT BE RESPONSIBLE FOR, ANY BUILDING CODE COMPLIANCE. The foregoing warranties give you specific legal rights and you may also have other rights which vary from state to state. 23 CFM Corporation 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 800-668-5323 • www.cfmcorp.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : No Author : Provided By MANUALSLIB.COM - http://www.manualslib.com/ Create Date : 2012:05:16 07:51:08Z Keywords : manuals, instruction manuals, user manuals, service manuals, user guides, pdf manuals, owners manuals, installation guides Modify Date : 2014:12:07 14:08:52+08:00 Subject : Search through 700.000 manuals online & and download pdf manuals. Has XFA : No XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Format : application/pdf Creator : Provided By MANUALSLIB.COM - http://www.manualslib.com/ Description : Search through 700.000 manuals online & and download pdf manuals. Title : ManualsLib - Makes it easy to find manuals online! Creator Tool : pdftk 1.44 - www.pdftk.com Metadata Date : 2014:12:07 14:08:52+08:00 Producer : itext-paulo-155 (itextpdf.sf.net-lowagie.com) Document ID : uuid:5af0efe6-bc40-ef4d-829f-aa88b79813d9 Instance ID : uuid:480c8808-c05b-8044-bcc5-00c062600c0d Page Count : 24EXIF Metadata provided by EXIF.tools