Pdf EXT ADA LAN Manual
2018-03-29
: Manual Pdf Ext-Ada-Lan Manual pdf_EXT-ADA-LAN_manual EXT-ADA-LAN-RX products
Open the PDF directly: View PDF
.
Page Count: 126
| Download | |
| Open PDF In Browser | View PDF |
Gen 2.0 Digital & Analog Audio over IP EXT-ADA-LAN-TX EXT-ADA-LAN-RX User Manual Version A2 Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this product near water. 6. Clean only with a dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 8. Do not install or place this product near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus. 11. Only use attachments/accessories specified by the manufacturer. 12. To reduce the risk of electric shock and/or damage to this product, never handle or touch this unit or power cord if your hands are wet or damp. Do not expose this product to rain or moisture. 13. Unplug this apparatus during lightning storms or when unused for long periods of time. 14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. 15. Batteries that may be included with this product and/or accessories should never be exposed to open flame or excessive heat. Always dispose of used batteries according to the instructions. 2 Warranty Information For the latest warranty coverage information, refer to the Warranty and Return Policy under the Connect section of the Gefen website at http://www.gefen.com/connect/warranty-andreturn-policy 3 Contact Us Technical Support 1-707-283-5900 1-800-472-5555 8:00 AM to 5:00 PM Monday - Friday, Pacific Time Email support@gefen.com Web http://www.gefen.com Mailing Address Gefen Nortek Security & Control, LLC c/o Customer Service 1800 S McDowell Blvd Petaluma, CA 94954 USA © 2018 Nortek Security & Control, LLC. All Rights Reserved. All trademarks are the property of their respective owners. Gefen and Nortek Security & Control, LLC reserve the right to make changes in the hardware, packaging, and any accompanying documentation without prior notice. 4 Operating Notes Important • When connecting through a Local Area Network, a managed gigabit switch is required. Jumbo Frame Support (8k or greater) and IGMP Snooping must be enabled. • A dedicated LAN is not required but highly recommended. • In a Multi-Format system, when using HDCP-encrypted content, only HDMI & DisplayPort™ inputs & outputs can accept or display content. • We recommend that Sender and Receiver are first connected directly and functionality/ performance is fully verified before integrating them into a Local Area Network. • Always make sure that all units within a system are running the latest firmware. • This product has been specifically designed for use with the Gefen Syner-G™ Software Suite, available for download at www.gefen.com. The Gefen Syner-G™ Discovery and Show-Me features simplify initial IP configuration • Gefen highly recommends the Gefen EXT-CU-LAN Matrix Controller for setting up and controlling the operation of an AV-over-IP network using these products. Alternatively, the Syner-G™ software can be used for IP configuration and firmware updates. • Shielded CAT-5e (or better) cables used between the Sender and the Receiver unit or between each unit and the IP switch, should not exceed 330 feet (100 meters). • By default, all Sender and Receiver units are set to channel 0. • If terminating network cables in the field, please adhere to the TIA/EIA568B specification. See the Network Cable Diagram (page 123) for details. This product uses UL-Listed power supplies 5 Operating Notes Licensing This product uses software that is subject to open source licenses, including one or more of the General Public License Version 2 and Version 2.1, Lesser General Public License Version 2.1 and Version 3, BSD, and BSD-style licenses. Distribution and use of this product is subject to the license terms and limitations of liability provided in those licenses. Specific license terms and Copyright Notifications are provided in the source code. For three years from date of activation of this product, any party may request, and we will supply, for software covered by an applicable license (e.g. GPL or LGPL), a complete machine-readable copy of the corresponding open source code on a medium customarily used for software interchange. The following software and libraries are included with this product and subject to their respective open source licenses: • • jQuery Linux 6 Features Features • Extends digital and analog audio, RS-232, and IR, using a Gigabit Local Area Network • Independent audio, RS-232, and IR routing** • Supports 2 channels of PCM (Analog L/R and Coaxial/Optical Digital outputs) and up to 5.1 channels (Coaxial/Optical Digital outputs) of Bitsream audio when connected to HDMI sources on HDMI capable Gefen AV over IP products. • Backward-compatible with first generation Gefen AV over IP products • Analog L/R, Coaxial Digital, and Optical Digital Inputs and Outputs • MFU (Mass-Firmware-Update), quick and automated configuration, and enhanced control capabilities and system security when used with the Gefen EXT-CU-LAN Matrix Controller • Enhanced API for added functionality with third-party control systems • Built-in web interface, Telnet, and UDP • Compatible with the Gefen Keyboard Switching Controller software, available for download at www. gefen.com • Supports 39,900 Senders and a combination of over 65,000 Sender and Receiver units, depending on the network bandwidth and number of ports on your network switch • 802.3af standard Power-over-Ethernet allows the new Sender and Receiver units to be powered through a standard PoE-enabled IP network switch, without the need for external power supplies • Two-port Gigabit Ethernet switch built into the Receiver unit • Field-updatable firmware via EXT-CU-LAN controller or the built-in web server interface • Locking power supply connectors • Low-profile, half-rack width Sender and Receiver enclosures are rack-mountable using EXT-RACK1U-GRY • Sender and Receiver can also be surface-mounted using the included L-brackets • Low profile Receiver enclosure features an IR Extender port and can be hidden away * Features and specifications are subject to change without notice. 7 Packing List Packing List - Sender unit The following items are included in the Sender Unit package. If any of these items are not present in the box when you first open it, please contact Gefen Technical Support as soon as possible. (1) (1) (1) (1) (4) (2) (4) (2) (1) Sender unit (EXT-ADA-LAN-TX) 5V 2.6A Power Supply 3.5mm-to-DB-9 Adaptor, M-F (ADA-MP-2-DB9-MF-AB) IR Emitter (EXT-IREMIT) Self-Adhesive Rubber Feet L-Shaped Mounting Brackets Machine screws for L-Shaped Mounting Brackets Machine screws for EXT-RACK-1U-GRY (sold separately) Quick-Start Guide Packing List - Receiver unit The following items are included in the Receiver Unit package. If any of these items are not present in the box when you first open it, please contact Gefen Technical Support as soon as possible. (1) (1) (1) (1) (4) (2) (4) (2) (1) Receiver unit (EXT-ADA-LAN-RX) 5V 2.6A Power Supply 3.5mm-to-DB-9 Adaptor, M-M (ADA-MP-2-DB9-MM-AB) IR Extender Module (EXT-RMT-EXTIRN) Self-Adhesive Rubber Feet L-Shaped Mounting Brackets Machine screws for L-Shaped Mounting Brackets Machine screws for EXT-RACK-1U-GRY (sold separately) Quick-Start Guide 8 Table of Contents Introduction.....................................................................................................................11 Sender Unit..............................................................................................................................11 Receiver Unit.......................................................................................................................... 13 Installation..................................................................................................................... 16 Local Area Network (LAN) Connection................................................................................. 16 Using a Direct Connection.................................................................................................... 20 Supplementary Connections.................................................................................................22 Sample Wiring Diagram........................................................................................................23 LED Status.......................................................................................................................24 Link 2. Power 2. 42 42 Setting the Audio Channel............................................................................................ 25 Setting the Channel using the Web Interface......................................................................25 Setting the Channel using the Front Panel...........................................................................26 Muting Audio..................................................................................................................28 Unicast & Multicast Modes...........................................................................................30 Configuring Unicast Mode.....................................................................................................30 Switching between Sender units in Unicast mode...............................................................32 Configuring Multicast Mode................................................................................................. 35 Discovery Mode.............................................................................................................. 37 Gefen Syner-G Discovery....................................................................................................... 37 Finding Your Device...............................................................................................................38 RS-232 Control................................................................................................................40 RS-232 under Unicast Mode..................................................................................................42 RS-232 under Multicast Mode...............................................................................................42 Audio Connections.........................................................................................................43 Sender Unit.............................................................................................................................43 Receiver Unit..........................................................................................................................43 Audio Port Priority.................................................................................................................44 Changing the Password.................................................................................................46 Utilities............................................................................................................................47 Reset using the Web Interface..............................................................................................47 Reboot using the Web Interface...........................................................................................49 Reboot using the Front Panel................................................................................................50 9 Table of Contents Telnet Access....................................................................................................................51 Commands...................................................................................................................... 52 Discovery Service....................................................................................................................52 Help 5. 25 Network 5. 25 Routing 5. 35 RX Specific..............................................................................................................................54 Serial 5. 55 System 5. 55 TX Specific.............................................................................................................................. 55 Web Interface......................................................................................................................... 55 Network Cable Diagram...............................................................................................123 Rack Tray Installation.................................................................................................. 124 Specifications*...............................................................................................................125 10 Introduction EXT-ADA-LAN-TX EXT-ADA-LAN-TX Sender Unit 2 1 3 4 Reset Prog 5 On Power Link Power 6 Link Reset 7 Off Prog Sel On Prog Off Prog Sel 8 9 10 11 12 13 EXT-ADA-LAN-TX EXT-ADA-LAN-TX 5V DC LAN (PoE) RS-232 IR In/Ext IR Out Line In Opt In Coax In 5V DC LAN (PoE) RS-232 IR In/Ext IR Out Line In Opt In Coax In ID Name Description 1 Power This LED indicator glows solid blue when the unit is powered. 2 Link This LED glows solid green when a link is established between the Sender and Receiver. 3 Reset Press this button, using the end of a paper clip or other pointed object, to perform a soft reset. 4 Prog This button is used for device recovery 5 Prog Sel For normal operation, this switch should be in the Off position. Setting this switch to the On position, places the unit in the ready-state for firmware recovery or debug operations. Digital and Analog Audio - Sender operations, in theover event ofIP a firmware update or other failure. over IP - Sender Digital and Analog Audio 11 Introduction ID Name Description 6 5V DC This power receptacle is used to connect the included 5V DC power supply. An external power supply is not required when connecting to a PoE-enabled switch using the LAN (PoE) port. 7 LAN (PoE) Connect a CAT-5e or better cable up to 330 feet/100 meters, from this port to a PoEcapable network switch. If a PoE switch is not available or the Sender and Receiver are connected directly, then the included 5V DC power supply must be connected to the Sender unit. 8 RS-232 Using the included 3.5mm-to-Female-DB-9 adapator, connect an DB-9 cable from this port to a RS-232 automation control unit. See RS232 Control (page 40) for more information. 9 IR In/Ext Connect an IR Extender (Gefen part no. EXT-RMT-EXTIRN) to this port. Alternatively, connect a 3.5mm mini-stereo connector from this port to the electrical IR output of an automation control system. 10 IR Out Connect an IR Emitter (Gefen part no. EXTIREMIT) from this port to the IR sensor of the device to be controlled. 11 Line In*** Connect a 3.5mm mini-stereo cable from this port to the analog audio source. 12 Opt In*** Connect a digital audio cable with TOSLINK® connectors from this port to the digital audio output of a source. 13 Coax In*** Connect a digital audio cable with RCA connectors from this port to the digital audio output of a source. *** Please note that when Line In on Sender is plugged in, it takes priority over the two digital inputs. If Line In is not connected, the two digital ports have the same priority. First one connected will be active. If both digital ports are connected and then the unit is powered on, Opt In will be active. To avoid inconsistent and/or confusing user experience, we recommend that only one type of input is connected at a time. 12 EXT-ADA-LAN-RX EXT-ADA-LAN-RX Introduction Receiver Unit 2 1 3 4 5 6 On Off Power Link Reset Prog Prog Sel On Off Power Link Reset Prog Prog Sel 7 8 9 10 11 – CH + – CH + 12 13 14 15 EXT-ADA-LAN-RX EXT-ADA-LAN-RX Coax Out Opt Out Line Out RS-232 IR In/Ext IR Out LAN 1 LAN 2 (PoE) 5V DC Coax Out Opt Out Line Out RS-232 IR In/Ext IR Out LAN 1 LAN 2 (PoE) 5V DC ID Name Description 1 Power This LED indicator glows solid blue when the unit is powered. 2 Link This LED glows solid green when a link is established between the Sender and Receiver. 3 Reset Press this button, using the end of a paper clip or other pointed object, to perform a soft reset. 4 Prog This button is used for device recovery operations, in the event of a firmware update or other failure. 5 Digital and Analog Audio over IP - Receiver Digital and Analog Audio over IP - Receiver Prog Sel For normal operation, this switch should be in the Off position. Setting this switch to the On position, places the unit in the ready-state for firmware recovery or debug operations. 13 Introduction ID Name Description 6 CH -/+ Press the - / + buttons button to decrement / increment, respectively, the current channel number. See Setting the Audio Channel (page 25) for more information. 7 Coax Out**** Connect a digital audio cable with RCA connectors from this port to the digital audio input of an AV receiver or amplifier. 8 Opt Out**** Connect a digital audio cable with a TOSLINK® connectors from this port to the digital audio input of an AV receiver or amplifier. 9 Line Out**** Connect a 3.5mm mini-stereo cable from this port to an amplifier or other audio output device. 10 RS-232 Using the included 3.5mm-to-Male-DB-9 adapator, connect a DB-9 cable from the Receiver to the display or another device to be controlled. See RS-232 Control (page 40) for more information. 11 IR In/Ext Connect an IR Extender (Gefen part no. EXT-RMT-EXTIRN) to this port. Alternatively, connect a 3.5mm mini-stereo connector from this port to the electrical IR output of an automation control system. 12 IR Out Connect an IR Emitter (Gefen part no. EXTIREMIT) from this port to the IR sensor of the device to be controlled. 13 LAN 1 Use this port to connect IP-enabled devices, or to daisy-chain additional Receiver units (only when a single source is used, otherwise bandwidth may be compromised). CAT-5e or better cables up to 330 feet/100 meters. This port is NOT PoE -capable. **** All three audio outputs of the Receiver can be used simultaneously, but if the signal format is Bitstream, the analog output will not work. 14 Introduction ID Name Description 14 LAN 2 (PoE) Connect a CAT-5e or better cable up to 330 feet/100 meters, from this port to a PoEcapable network switch. If a PoE switch is not available or the Sender and Receiver are connected directly, then the included 5V DC power supply must be connected to the Receiver unit. 15 5V DC This power receptacle can be used to connect the included 5V DC power supply. An external power supply is not required when connecting to a PoE-enabled switch using the LAN 2 (PoE) port. 15 Installation The Gen 2.0 AV and KVM over IP Sender and Receiver units can be connected directly or through a Local Area Network (LAN). Both installations will be covered. Local Area Network (LAN) Connection When connecting the Sender and Receiver units to a Local Area Network (LAN), DHCP, static, or APIPA (Automatic Private IP Addressing) IP modes can be used. DHCP mode will use the EXT-ADA-LAN-TX DHCP server to automatically assign an IP address for each Sender and Receiver unit that is connected to the network. Static IP mode will allow the IP address for each Sender and Receiver unit to be configured manually. Contact your network administrator if necessary. APIAP mode assigns a class-B IP address, in the 169.254.x.x range, to the Sender and Receiver units, if a DHCP server is not available. 1. Connect a CAT-5e (or better) cable between On Off the LAN (PoE) port on the Sender unit and a Power Link Reset Prog Prog Sel Gigabit PoE-enabled IP switch. 2. Connect LAN 2 (PoE) on the Receiver unit to the same network switch. Each cable run can be up to 330 feet (100 meters). Sender unit EXT-ADA-LAN-TX 5V DC LAN (PoE) RS-232 IR In/Ext IR Out Line In Opt In Coax In to PoE-compatible switch 3. If NOT USING A PoE-compliant switch, then connect the included 5V DC power supplies to the Sender and Receiver units. Important If the IP switch is PoE-compliant and the Sender and Receiver are connected through their PoE ports, external power supplies will not be required. However, additional Receivers or other devices connected to the LAN 1 port of a Receiver will require an external power supply. Digital and Analog Audio over IP - Sender 16 Installation EXT-ADA-LAN-RX Coax Out Opt Out Line Out RS-232 IR In/Ext IR Out LAN 1 LAN 2 (PoE) 5V DC Receiver unit Connect to LAN 4. Launch the Gefen Syner-G™ app to discover the IP address of the Sender/Receiver unit. See the Gefen Syner-G™ User Manual for more information. 5. Click the desired unit from the list. The currently selected unit will be highlighted in red. 6. Use the fields in the Device Settings section to change the IP settings, as necessary. Digital and Analog Audio over IP - Receiver Device Settings Selected Unit 17 Installation 7. Once all IP settings have been adjusted, click the Apply button. 8. Click the Reboot button to apply changes. 9. Repeat steps 4 - 8 for each Sender and Receiver unit as necessary. 10. Open your Web browser and enter the IP address of the desired Sender or Receiver unit in the address bar. 11. The Login screen will be displayed. 12. In order to change network settings, you must login as “Administrator”. Select the “Administrator” username from the drop-down list. 13. Type the password in the Password field. The default password for “Administrator” is admin. The password is case-sensitive and will be masked as it is entered. Note Passwords and operating features can be changed when logged in as Administrator. The User option has limited access. To change password credentials, see Changing the Password (page 60) for more information. 18 Installation 14. Click the Login button. 15. The Network will automatically be selected. The current IP Mode will be highlighted within the IP Setup window group. 16. Click the desired IP Mode button. • If Static mode is selected, then enter the IP Address, Subnet Mask, and Default Gateway. Contact your system administrator if necessary. • If DHCP mode is selected, then the IP address, subnet mask, and default gateway will be specified by the DHCP server. 17. Click the Apply button to save the changes. This operation will require a reboot. 18. Click the Reboot button near the bottom of the page. 19. Repeat steps 12 - 21 for each Sender and Receiver to be configured. After the desired IP settings have been applied, set the audio channel for each Sender unit. See Setting the Audio Channel (page 25) for more information. Important The use of a Managed Gigabit switch with “Jumbo Frame” and “IGMP Snooping” capability is required when connecting the Gefen AV over IP products to a network. The switch should be set to greater than 8K and IGMP Snooping must be enabled. 19 Installation Using a Direct Connection By default, all Senders and Receivers are shipped in APIPA (Auto) mode. This network mode is used for directly connecting Sender and Receiver units to one another. APIAP mode assigns a class-B IP address, in the 169.254.x.x range, to the Sender and Receiver units, if a DHCP server is not available. When using a direct connection, each unit can remain in Auto mode and can be assigned a static or DHCP IP address using the Gefen Syner-G sofrware, or manually through the built-in web interface. EXT-ADA-LAN-TX 1. Connect an HDMI cable to connect the source to the HDMI In port on the Sender unit. 2. Connect an HDMI cable from the display to the HDMI Out port on the Receiver unit. 3. On the OffLAN (PoE) port on the Sender unit to the Connect a CAT-5e (or better) cable from Power Link Reset Prog Sel LAN 1 or LAN 2 (PoE) port onProgthe Receiver unit. The other LAN port can then be used for connecting (daisy-chaining) an additional Receiver unit. Each cable run can be up to 330 feet (100 meters). Please note that PoE is not active in direct connection. The Sender and all connected Receivers will need to be powered using their external power supplies. EXT-ADA-LAN-RX – On Power 5V DC Link Reset Prog + EXT-ADA-LAN-TX Prog Sel RS-232 LAN (PoE) CH Off IR In/Ext IR Out Line In Opt In Coax In Sender unit EXT-ADA-LAN-RX Coax Out Receiver unit Opt Out Line Out RS-232 IR In/Ext IR Out LAN 1 LAN 2 (PoE) 5V DC to IP-enabled devices 4. Connect the included 5V DC locking power supplies to both the Sender unit and Receiver unit. Do not overtighten the locking connectors. Plug the power supplies to available electrical outlets. 5. See Local Area Network (LAN) Connection (page 16) and follow steps 4 - 19, in order to access the built-in Web interface. Digital and Analog Audio over IP - Sender 6. Make note of both IP addresses. These IP addresses can be entered in a Web browser to access the built-in Web interface. 20 Digital and Analog Audio over IP - Receiver Installation 7. Set the audio channel. By default, both the Sender and Receiver unit are set to channel 0. See Setting the Audio Channel (page 25) for more information. 8. Once both Sender and Receiver units are configured using the built-in Web interface, the shielded CAT-5e cable, between the PC and the Receiver unit, can be disconnected. 9. See Supplementary Connections (page 22) for instructions on connecting IR, RS-232, and audio cables. 21 Installation ►► IR Supplementary Connections 1. Connect an IR Emitter (Gefen part no. EXT-IREMIT) to the IR Out port on the Sender unit and attach it to the IR sensor on the device to be controlled. 2. Connect an IR Extender (Gefen part no. EXT-RMT-EXTIRN) to the IR In/Ext port on the Sender unit to control the AV receiver. 3. Connect an IR Emitter (Gefen part no. EXT-IREMIT) to the IR Out port on the Receiver unit and attach it to the IR sensor on the device to be controlled. 4. Connect an IR Extender (Gefen part no. EXT-RMT-EXTIRN) to the IR In/Ext port on the Receiver unit to control the audio source. ►► Audio See Audio Connections (page 43) for more information on connections and port priorities. 5. Connect a 3.5mm mini-stereo cable from the Line In*** port on the Sender unit to the analog audio source. 6. Connect a optical audio cable from the Opt In*** port on the Sender unit to the TOSLINK® connector on the audio source. 7. Connect a digital audio coaxial cable from the Coax In*** port on the Sender unit, to the digital audio source. 8. Connect a 3.5mm mini-stereo cable from the Line Out**** port on the Receiver unit to the analog audio amplifier. 9. Connect a optical audio cable from the Opt Out**** port on the Receiver unit to the TOSLINK® input port on the audio amplifier. 10. Connect a digital audio coaxial cable from the Coax Out**** port on the Receiver unit to the digital audio input port on the audio amplifier. ►► RS-232 12. Connect an RS-232 cable from the PC or automation system to the RS-232 port on the Sender unit. 13. Connect an RS-232 cable from the Receiver unit to the RS-232 device to be controlled. *** Please note that when Line In on Sender is plugged in, it takes priority over the two digital inputs. If Line In is not connected, the two digital ports have the same priority. First one connected will be active. If both digital ports are connected and then the unit is powered on, Opt In will be active. To avoid inconsistent and/ or confusing user experience, we recommend that only one type of input is connected at a time. **** All three audio outputs of the Receiver can be used simultaneously, but if the signal format is Bitstream, the analog output will not work. 22 Installation Sample Wiring Diagram Blu-ray Player IR Emitter Automation Control Device CAT-5e CABLE RS-232 CABLE 3.5MM AUDIO CABLE OPTICAL DIGITAL AUDIO COAXIAL DIGITAL AUDIO IR IN IR OUT To PoE IP Switch EXT-ADA-LAN-TX 5V DC LAN (PoE) RS-232 IR In/Ext IR Out Line In Opt In Coax In EXT-ADA-LAN Sender Blu-ray Player OR OR IR Extender for remote amplifier control RS-232 Controlled Device IR Extender for source control Analog Audio Source To PoE IP Switch Powered Speakers or Audio Amplifier w/analog L/R input EXT-ADA-LAN-RX Coax Out Opt Out Line Out RS-232 IR In/Ext IR Out LAN 1 LAN 2 (PoE) 5V DC EXT-ADA-LAN Receiver Audio Amplifier w/ S/PDIF digital input Audio Amplifier w/ optical digital input IR Emitter All three audio outputs of the Receiver can be used simultaneously, but if the signal format is Bitstream, the analog output will not work. EXT-ADA-LAN Note The wiring diagrams above show an additional IR Emitter (Gefen part no. EXTIREMIT), an additional IR Extender Module (Gefen part no. EXT-RMT-EXTIRN), and various interconnect cables that are not included with the products. The Emitter, Extender Module, and select cables are available for purchase from your Gefen dealer or distributor. 23 LED Status The Power and Link LED indicators on the Sender and Receiver unit provide basic information on their current status. The information, in the tables below, applies to both the Sender and Receiver unit. Link Status Description Off • Connection is not established. • Check the cable between the Sender and Receiver unit. On • Connection is established and audio is streaming. Blinking • System is in a state of transition. Connection is established but streaming has not started. • No audio source detected. • Check that the Receiver unit is connected to the host. Power Status Description Off • No power. On • Power is on and the system is ready. Blinking • System is booting (not ready). 24 Setting the Audio Channel In order for a Sender and Receiver unit to communicate with one another, they must both be set to the same channel. This is similar to changing the channel on a set-top box in order to view a different program. Pressing and releasing either the CH + or CH - buttons on the front of the Receiver unit can also be used to change the channel. Both methods will be covered in this section. By default, all Sender and Receiver units are set to channel 0 (zero). Setting the Channel using the Web Interface 1. Access the Web interface by entering the IP address of the desired Sender or Receiver unit. 2. Login as “Administrator” or “User”. 3. Click the Functions tab. The current channel is displayed within the Channel Setup window group. 4. Type the desired channel number. Channel numbers can range from 0 to 39900. 5. Click the Apply button on the right-hand side of Channel Setup window group. 6. The following message will be displayed, at the top of the page, indicating that the selected channel has been applied. If the entered value is invalid, then the following message will be displayed: 7. Access the Web interface of the next unit (Sender or Receiver) by entering its IP address. 8. Repeat steps 1 - 5 for each Sender and Receiver to be changed. 25 Setting the Audio Channel EXT-ADA-LAN-RX Setting the Channel using the Front Panel 1. Press the CH - or CH + change the current channel number. Channel numbers range from 0 to 39900 and can be viewed in the Web interface. – On Power Link Reset Prog CH + Off Prog Sel Receiver unit To set the audio channel on a Sender unit, use the Web interface. See Setting the Channel using the Web Interface (page 25) for more information. EXT-ADA-LAN-RX The illustration below shows one Receiver unit and three Sender units. The numbers indicate Coax theOut audioOptchannel for each unit. IRHere, theIR Out ReceiverLAN unit is currently set to channel Out Line Out RS-232 In/Ext 1 LAN 2 (PoE) 5V DC 2 and is receiving the signal from the Sender unit, set to channel 2. Receiver unit Out LAN 2 Sender unit 2 Sender unit 1 In Sender unit 5 In Digital and Analog Audio over IP - Receiver In To switch the channel, and view the source that is connected to the Sender on channel 5, press and release the CH + button to increment the channel. The web interface will reflect the current channel change. 26 Setting the Audio Channel 2. The Receiver unit, on channel 5, is now receiving the signal from the Sender unit on channel 5. Receiver unit Out LAN 5 Sender unit 2 Sender unit 1 In Sender unit 5 In In 27 Muting Audio Use the Mute Audio option on a Sender unit to prevent audio from being transmitted to each of the connected Receiver units (multicast mode only). Use the Mute Audio option on the Receiver units, to selectively block audio on each Receiver unit. ►► Receiver Units 1. Access the Web interface of a Receiver unit by entering the IP address in the address bar of the browser. 2. Login as “Administrator”. 3. Click the Functions tab. 4. Under the Audio over IP window group, check the Audio Mute box to block the audio output on the Receiver unit. Deselect this check box to re-enable audio. 5. Click the Apply button within the Audio over IP group. 6. Repeat steps 1 through 5 for each Receiver unit in the system. 28 Muting Audio ►► Sender Units Note The Mute Audio option on Sender units is only applicable in multicast mode. 1. Access the Web interface of a Sender unit by entering the IP address in the address bar of the browser. 2. Login as “Administrator”. 3. Click the Functions tab. 4. Under the Audio over IP window group, check the Audio Mute box to prevent audio from being transmitted to each of the connected Receiver units. Deselect this check box to re-enable audio output on all connected Receiver units.. 5. Click the Apply button within the Audio over IP group. 6. Repeat steps 1 through 5 for each Sender unit in the system. 29 Unicast & Multicast Modes Configuring Unicast Mode The term unicast is used to describe a configuration where information is sent from one point to another point. It is possible to have multiple Sender and Receiver units connected in a system. However, in unicast mode a Sender unit can communicate with only one Receiver unit at a time. In unicast mode, the Gefen AV over IP products function similar to an audio switcher. Note The Gefen Audio over IP Sender and Receiver units are shipped from the factory in unicast mode. The illustration, below, shows 3 Sender units (S1, S2, and S3) and 2 Receiver units (R1 and R2) on a network, operating in unicast mode. The audio channels are notated in blue. Figure 2.1 - Unicast mode: A Sender unit can communicate with only one Receiver unit at a time. Receiver unit Out 2 LAN R 2 Sender unit Receiver unit 1 S 2 R 3 Out 1 Sender unit In S 2 1 Sender unit S In 1 5 In 1. Access the Web interface for each Sender and Receiver unit that will be using unicast mode. In this example, we will start with Receiver unit R1. 2. Login as “Administrator”. Tip In unicast mode, the Gefen AV over IP Senders and Receivers function as an audio switcher. 30 Unicast & Multicast Modes 3. Click the Network tab. 4. Click the Unicast button under the Network Mode window group. When selected, the Unicast button will be highlighted in red. 5. Click the Apply button in the lower-right corner of the Network Mode group. 6. The following message will be displayed, at the top of the page, indicating that the casting mode has been applied to the Sender or Receiver unit. 7. Click the Reboot button at the bottom of the page. If the Reboot button is not clicked, the following message will be displayed, indicating that the unit must be rebooted. 8. Repeat steps 1 - 7 in order to configure the Sender unit for unicast mode. Important When switching between unicast and multicast modes, both Sender and Receiver units must be set to the same mode. 31 Unicast & Multicast Modes Switching between Sender units in Unicast mode When multiple Sender and Receiver unit are used in unicast mode, the Gefen Audio over IP Sender and Receivers behave as a switcher. In unicast mode, a Sender unit can communicate with only one Receiver unit at a time. In the example below, Receiver unit R1 will be switched to receive the source connected to Sender unit S1. To do this, simply change the audio channel. Figure 2.2 - Unicast mode: Receiver unit R1 is connected to Sender unit S2. Receiver unit Out 2 LAN R 2 Sender unit Receiver unit 1 S 2 R 3 Out 1 Sender unit In S 2 1 Sender unit S In 1 5 In 1. Access the Web interface for Receiver unit R1. 2. Login as “Administrator”. 3. Click the Network tab and change the audio channel. Refer to Setting the Audio Channel (page 25) if necessary. 4. Click the Apply button. 5. The following message will be displayed, at the top of the page, indicating that the new channel has been applied to the Sender or Receiver unit. 6. Receiver unit R1 is now receiving the audio source connected to Sender unit S1, as shown on the next page. 32 Unicast & Multicast Modes Figure 2.3 - Unicast mode: Receiver unit R1 is now connected to Sender unit S1. Receiver unit Out 2 LAN R Sender unit 2 Out Receiver unit 3 Sender unit 1 5 S 2 R In S 2 1 Sender unit In S 1 5 In Now, observe the result when both Sender S1 and S2 are set to channel 5: Figure 2.4 - Unicast mode violation: Two Sender units (S1 and S2) using the same audio channel. Receiver unit Out 2 LAN R Sender unit 2 Out Receiver unit 2 S 3 R Sender unit 1 5 In 5 2 S Sender unit In S 1 5 In In this example, Receiver R1 will continue to receive audio data from Sender S1, even though Sender S2 is set to the same audio channel. The reason for this is because Receiver R1 and Sender S1 were already set to the same audio channel and communicating (as depicted in Figure 2.3). However, this scenario violates the unicast mode rule: A Sender unit can communicate with only one Receiver unit at a time. 33 Unicast & Multicast Modes When using unicast mode, each of the Sender units must be assigned a unique audio channel and should never be changed. Use the Receiver unit to switch (channels) between Sender units. Note In unicast mode, if an additional Sender unit is introduced into a system with the same channel as another Sender unit, then the Receiver unit will continue to receive audio data from the Sender unit which was connected first. 34 Unicast & Multicast Modes Configuring Multicast Mode The term multicast is used to describe a configuration where information is sent from one or more points to a set of other points. For example, a single Sender unit can transmit data to multiple Receiver units. In addition, if multiple Sender units are used, each Sender unit can transmit data to any Receiver that is not already receiving data from another Sender unit. In multicast mode, the Senders and Receivers function similar to a KVM matrix. The illustration, below, shows 3 Sender units (S1, S2, and S3) and 2 Receiver units (R1 and R2) on a network, operating in multicast mode. The audio channels are shown in blue. Figure 2.5 - Multicast mode: A Sender unit can communicate with multiple Receiver units. Receiver unit Out 1 LAN R 2 Sender unit Receiver unit 1 2 R S 3 Out 1 Sender unit In 1 2 S Sender unit In S 1 5 In 1. Access the Web interface for each Sender and Receiver unit that will be using multicast mode. In this example, we will start with Receiver S2. 2. Login as “Administrator”. Note In multicast mode, the Gefen AV over IP Senders and Receivers function as an audio matrix. 35 Unicast & Multicast Modes 3. Click the Network tab. 4. Click the Multicast button under the Network Mode window group. When selected, the Multicast button will be highlighted in red. 5. Click the Apply button in the lower-right corner of the Network Mode group. The following message will be displayed, at the top of the page, indicating that the casting mode has been applied to the Sender or Receiver unit. 6. Click the Reboot button at the bottom of the page. If the Reboot button is not clicked, the following message will be displayed, indicating that the unit must be rebooted. 7. Repeat the steps above in order to configure the Sender unit to multicast mode. Important When switching between unicast and multicast modes, both Sender and Receiver units must be set to the same mode. 36 Discovery Mode Gefen Syner-G Discovery Enabling the Gefen Syner-G Discovery feature allows the Gefen Syner-G Software Suite or Gefen Discovery Tool App to locate a Sender and/or Receiver on a network. Once the software is able to locate the unit, IP settings can be changed as desired. 1. Access the Web interface by entering the IP address of a Receiver or Sender unit. 2. Login as “Administrator”. 3. Click the Network tab. 4. Under the IP Setup window group, check the Gefen Syner-G Discovery box to allow the Gefen Syner-G software to locate the unit. If you do not want the unit to be discoverable, then un-check this box. 5. Click the Apply button. 6. Click the Reboot button at the bottom of the page to restart the unit and apply the change. 37 Discovery Mode Finding Your Device If several Sender and Receiver unit pairs are connected on a network, you may need to physically identify a particular Sender and/or Receiver unit. In such a case, use the Find Your Device feature. 1. Access the Web interface by entering the IP address of a Receiver or Sender unit. 2. Login as “Administrator”. 3. Click the Network tab. 4. Under the IP Setup window group, click the Show Me button. By default, the Hide Me button will be selected. Although shown, below, it is not necessary to have the Gefen Syner-G Discovery option enabled in order to use the Find Your Device feature. 38 Discovery Mode 5. The following message will be displayed, at the top of the page, indicating that the EXT-ADA-LAN-RX LED indicators on the unit are blinking. 6. The Power and Link LED indicators will continue to blink until the Hide Me button is clicked. – On Power Link Reset Prog CH + Off Prog Sel Receiver unit (shown) 7. Click the Hide Me button to stop both LED indicators from blinking. EXT-ADA-LAN-RX Coax Out 8. Opt Out Line Out RS-232 IR In/Ext IR Out LAN 1 LAN 2 (PoE) 5V DC The Power and Link LED indicators will stop blinking and the following message will be displayed at the top of the page. Digital and Analog Audio over IP - Receiver 39 RS-232 Control The Gefen Audio over IP Senders and Receivers support RS-232 pass-through, allowing the control of remote RS-232 devices. The Sender and Receiver unit which are being used to passthrough the RS-232 data must be set to the same baud rate as the RS-232 host and client. In the example below, an RS-232 device has been connected to Receiver R1. We want to control this product from Sender unit S3, using an automation control device. The channel numbers are listed in blue. Figure 2.6 - Basic RS-232 connection Receiver unit Out R 02 2 Sender unit Receiver unit 1 R S 12 3 Out Automation Control Device LAN Sender unit 12 In 2 S Sender unit 09 S In 1 RS-232 device 05 In Table 2.1 - RS-232 settings for an arbitrary RS-232 device. Description Setting Baud rate 19200 Data bits Parity Stop bits Hardware flow control 8 None 1 None Confirm that the same RS-232 settings are assigned to both the Sender and Receiver units. To do this, access the Web interface on both the required Sender unit and Receiver unit to set the proper RS-232 settings. Follow the instructions on the next page. 40 RS-232 Control 1. Access the Web interface for the Sender unit and login as “Administrator”. 2. Click the Functions tab. 3. Locate the Serial over IP group and change the RS-232 settings to match the settings of the RS-232 device that is being used. In this case, we need to use the settings from Table 2.1 (see previous page). 4. Make sure that the Enable Serial over IP box is checked. 5. Click the Apply button in the lower-right corner of the Serial over IP group. Important If Enable Serial over IP is not checked, then RS-232 pass-through will be disabled. 6. The following message will be displayed, at the top of the page, indicating that the new Serial over IP options have been applied. 7. Click the Reboot button at the bottom of the page. If the Reboot button is not clicked, the following message will be displayed, indicating that the unit must be rebooted. 8. Repeat steps 1 - 7 for the Receiver unit. 41 RS-232 Control RS-232 under Unicast Mode In unicast mode, a Sender unit will be able to communicate with only one Receiver unit at a time. Figure 2.7 - In unicast mode, the host can talk to only one RS-232 device at a time. RS-232 device Receiver unit Out R 02 2 Out Automation Control Device LAN Sender unit Receiver unit S 3 R 1 12 Sender unit 12 S 2 RS-232 device In Sender unit 09 In 1 S 05 In RS-232 under Multicast Mode In multicast mode, a Sender unit can communicate with multiple Receiver units simultaneously. Figure 2.8 - In multicast mode, the host can talk to multiple RS-232 devices. RS-232 device Receiver unit Out R 12 2 Sender unit Receiver unit 1 R 12 S 3 Out Automation Control Device LAN Sender unit 12 S 2 RS-232 device Sender unit 09 1 S 05 In 42 In In Audio Connections Audio works in both unicast and multicast modes. However, audio connections have different priorities, based on the type and the order in which they are connected. Sender Unit 1. EXT-ADA-LAN-TX Connect a 3.5mm mini-stereo cable from the Line In*** port on the Sender unit to the analog audio source. 2. Connect a optical audio cable from the Opt In*** port on the Sender unit to the TOSLINK® connector on the audio source. 3. Connect a digital audio coaxial cable from the Coax In*** port on the Sender unit, to the On Off Power Link Prog Sel digital audio source. Reset Prog Connect to Line Out on analog source EXT-ADA-LAN-TX 5V DC LAN (PoE) RS-232 IR In/Ext IR Out Line In Opt In Coax In Sender unit Connect to optical audio output on source Connect to digital audio output on source *** See Audio Port Priority section. Receiver Unit 1. Connect a 3.5mm mini-stereo cable from the Line Out**** port on the Receiver unit to powered speakers or an audio amplifier. 2. Connect a optical digital audio cable with TOSLINK® connectors from the Opt Out**** Digital and Analog Audio over IP - Sender port on the Receiver unit to the digital input of an audio amplifier. 3. Connect a coaxial digital audio cable from the Coax Out**** port on the Receiver unit to the digital input port of an audio amplifer. 43 – On Power Link Reset Prog CH + Audio Connections Off Prog Sel Connect to powered speakers or audio amplifier Receiver unit EXT-ADA-LAN-RX Coax Out Opt Out Line Out RS-232 IR In/Ext IR Out LAN 1 LAN 2 (PoE) 5V DC Connect to optical audio input on audio amplifier Connect to digital audio input on audio amplifier **** See Audio Port Priority section. Digital and Analog Audio over IP - Receiver Audio Port Priority When the Line In port on the Sender unit is connected, it takes priority over both digital inputs (Opt In and Coax In). If Line In is not connected, then the two digital ports have the same priority. The first digital port that receives a connection will become the active audio input port. If both digital ports are connected, after the unit is powered-on, then the Opt In port always has priority and will become the active audio input port. All three audio ports (Line Out, Opt Out, and Coax Out) output the same audio signal. See the table on the following page for a summary of audio port priorities. 44 Audio Connections Audio Port Priority Summary Transmitter Line In Opt In Receiver Coax In Line Out Opt Out Coax Out Line In Line In Line In Opt In Opt In Opt In Coax In Coax In Coax In Line In Line In Line In Line In Line In Line In First Second Opt In Opt In Opt In Second First Coax In Coax In Coax In Line In Line In Line In 45 Changing the Password 1. Access the Web interface for the Sender / Receiver unit. 2. Login as “Administrator”. 3. Click the System tab. 4. Under the Password Change window group, enter the new password for the desired username. Note that the new password will not be masked when it is entered. 5. Click the Change button. 46 Utilities Reset using the Web Interface All Senders and Receivers can be reset using the web interface or using the buttons on the front panel. When using the Web interface, the Sender / Receiver units will automatically be reset to Auto IP mode. When using the front-panel buttons, the Sender / Receiver can be reset to either Auto IP or Static IP mode. Note Once a unit has been reset to Auto IP mode, the connection to the Web interface will be terminated. To reestablish a connection to the Web interface, from your computer, see Installation (page 17). 1. Access the Web interface for the desired Sender / Receiver unit. It does not matter which unit is reset first. 2. Login as “Administrator”. 3. Click the System tab. 4. Click the Utilities rollout. 5. Click the Factory Default button. 47 Utilities 5. Both the Power and Link LED indicators will begin to flash. – On Power Link Reset Prog CH + Off Prog Sel Receiver unit (shown) 6. After both LED indicators stop flashing, the unit will be reset. 7. Repeat the process for each unit. EXT-ADA-LAN-RX Coax Out Opt Out Line Out RS-232 IR In/Ext IR Out LAN 1 LAN 2 (PoE) 5V DC Digital and Analog Audio over IP - Receiver 48 Utilities Reboot using the Web Interface The Sender and Receiver units can be rebooted in three different ways: Using the Web interface, the Reset button on the front panel, or simply disconnecting and reconnecting the power. 1. Access the Web interface for the Sender / Receiver unit. 2. Login as “Administrator”. 3. Click the System tab. 4. Click the Utilities rollout. 5. Click the Reboot button. 6. After a few moments, the Power LED indicator will flash. 7. Several seconds later, the Power LED indicator will glow solid blue and the Link LED indicator will begin to flash. 8. After both LED indicators stop flashing, the reboot process will be complete. 49 Utilities Reboot using the Front Panel 1. Press the Reset button, on the desired Sender or Receiver unit, using the end of a paper clip or other sharp pointed object. 2. After a few moments, the Power LED indicator will flash. 3. Several seconds later, the Power LED indicator will glow solid blue and the Link LED indicator will begin to flash. 4. After both LED indicators stop flashing, the reboot process will be complete. EXT-ADA-LAN-TX Reset button EXT-ADA-LAN-RX On Power Link Reset Prog Off Prog Sel Sender unit Reset button EXT-ADA-LAN-TX – 5V DC Power Off RS-232 On IR In/Ext LAN (PoE) Link Reset Prog CH IR Out + Line In Opt In Coax In Prog Sel Receiver unit EXT-ADA-LAN-RX Coax Out Opt Out Line Out RS-232 IR In/Ext IR Out LAN 1 LAN 2 (PoE) 5V DC Digital and Analog Audio over IP - Sender 50 Telnet Access Note By default, the Telnet login credentials are disabled. This setting is required when using the Matrix controller (Gefen part no. EXT-CU-LAN) but can be enabled for security purposes. Use the #use_telnet_login command to enable or disable this feature. 1. Launch the desired terminal application (e.g. Windows Hyperterminal, etc). 2. Within the terminal program, enter the IP address of the Sender or Receiver unit that you wish to control. 3. Enter the TCP listening port. The default listening port is 23. 4. After the correct settings have been used in the terminal program, information similar to the following will be displayed. In the example, below, we are connected to the client (Receiver unit) and Telnet login has been enabled: ------------- Welcome to the Gefen Telnet Server ---------ast2-client001C9103C8B3 login: 5. Login as “Administrator”. The default password is “admin”. To change the Telnet password, see the #set_telnet_pass command. 6. Type #help for a list of commands or refer to the tables on the following pages. 51 Commands Important Commands that are limited to a Sender or Receiver unit are marked as “Tx only” and “Rx only”, respectively. Unless otherwise noted, commands can be used when connected to either a Sender or Receiver unit. Discovery Service Command Description #get_device_desc Displays the device description #get_discovery Displays the current state of the discovery service #get_discovery_mode Displays the discovery read/write mode #get_showme Displays the status of the showme state #set_device_desc Sets the device description #set_discovery Enables or disables the discovery service #set_discovery_mode Sets the discovery mode #set_showme Enables or disables the “show me” feature Help Command Description #help Displays a list of available commands Network Command Description #get_gateway Displays the gateway IP address #get_ip_address Displays the IP address #get_ip_mode Displays the IP mode #get_ipconfig Displays the IP configuration information #get_net_mode Displays the network casting mode #get_netmask Displays the subnet mask address #get_remote_udp_access Displays the remote UDP access state #get_remote_udp_ip Displays the remote UDP IP address #get_remote_udp_port Displays the remote UDP listening port #get_telnet_access Displays the Telnet access state 52 Commands Command Description #get_telnet_login Displays the status of the Telnet login #get_telnet_port Displays the Telnet listening port #get_telnet_welcome Displays the Telnet welcome message #get_udp_access Displays the UDP access state #get_udp_port Displays the UDP listening port #get_web_port Displays the HTTP listening port #set_gateway Sets the gateway address #set_ip_address Sets the IP address #set_ip_mode Sets the IP mode #set_net_mode Sets the network casting mode #set_netmask Sets the subnet mask address #set_remote_udp_access Enables or disables remote UDP access #set_remote_udp_ip Sets the remote UDP IP address #set_remote_udp_port Sets the remote UDP listening port #set_telnet_access Enables or disables Telnet access #set_telnet_login Enables or disables the Telnet login #set_telnet_pass Sets the Telnet password #set_telnet_port Sets the Telnet listening port #set_telnet_welcome Sets the Telnet welcome message #set_udp_access Enables or disables UDP access #set_udp_port Sets the UDP listening port #set_web_port Sets the HTTP listening port Routing Command Description #get_rx_channel Displays the channel of the Receiver unit (Rx only) r Routes an input to a Receiver unit (Rx only) 53 Commands RX Specific Command Description #get_clk_lock Displays the audio clock lock #get_rx_id Displays the ID of the Receiver unit #get_rx_mute Displays the audio mute feature state #set_clk_lock Sets the audio clock lock #set_rx_id Sets the ID of the Receiver unit #set_rx_mute Sets the audio mute feature 54 Commands Serial Command Description #get_serial_allow Displays the Serial-over-IP state #get_serial_baud Displays the serial baud rate setting #get_serial_bits Displays the serial data bits setting #get_serial_parity Displays the serial parity setting #get_serial_stop Displays the serial stop bits setting #set_serial_allow Enables or disables Serial-over-IP mode #set_serial_baud Sets the baud rate for the serial port #set_serial_bits Sets the data bits for the serial port #set_serial_parity Sets the parity setting for the serial port #set_serial_stop Sets the number of stop bits for the serial port System Command Description #get_firmware_version Displays the firmware version #factory_reset Resets the unit to factory-default settings #fw_upgrade Upgrades firmware using external file #reboot Reboots the unit TX Specific Command Description #get_tx_channel Displays the audio channel #set_tx_channel Sets the audio channel Web Interface Command Description #set_webui_ad_pass Sets the administrator password for the web UI #set_webui_user_pass Sets the user password for the web UI 55 Commands #help Displays a list of available commands. The commands listed are specific to either the Sender or Receiver unit. Syntax #help Parameters None Example #help #HELP #FACTORY_RESET #FW_UPGRADE #GET_CLK_LOCK #GET_DEVICE_DESC #GET_DISCOVERY #GET_DISCOVERY_MODE #GET_EDID_COPY #GET_FIRMWARE_VERSION #GET_GATEWAY #GET_HDCP #GET_IP_ADDRESS #GET_IP_MODE #GET_IPCONFIG #GET_NET_MODE #GET_NETMASK #GET_REMOTE_UDP_ACCESS #GET_REMOTE_UDP_IP #GET_REMOTE_UDP_PORT #GET_RX_CHANNEL ... ... 56 Commands #factory_reset Resets the unit to factory-default settings. param1 must be included and set to 1. Syntax #factory_reset param1 Parameters param1 Integer 1 Example #factory_reset 1 RESET TO FACTORY DEFAULTS Related Commands #reboot 57 Commands #fw_upgrade Upgrades the firmware from the command. Syntax #fw_upgrade filename Parameters filename String Example #fw_upgrade firmware_file_v2.bin 58 Commands #get_clk_lock Displays the audio clock lock. Syntax #get_clk_lock Parameters None Example #get_clk_lock CLK_LOCK 0 Related Commands #set_clk_lock 59 Commands #get_device_desc Displays the description of the Sender / Receiver unit. Syntax #get_device_desc Parameters None Example #get_device_desc DEVICE DESCRIPTION IS Genius Sender 2 Related Commands #set_device_desc 60 Commands #get_discovery Displays the current discovery mode setting. Syntax #get_discovery Parameters None Example #get_discovery DISCOVERY SERVICE SET TO ENABLED Related Commands #set_discovery #set_showme 61 Commands #get_discovery_mode Displays the current discovery mode setting. Syntax #get_discovery_mode Parameters None Example #get_discovery_mode DISCOVERY MODE 1 Related Commands #set_discovery #set_discovery_mode #set_showme 62 Commands #get_firmware_version Displays the firmware version. Syntax #get_firmware_version Parameters None Example #get_firmware_version FIRMWARE VERSION IS 1.83hv Related Commands #fw_upgrade 63 Commands #get_gateway Displays the gateway address of the Sender/Receiver unit. Syntax #get_gateway Parameters None Example #get_gateway GATEWAY: 192.168.0.1 Related Commands #get_ip_address #get_ip_mode #get_ipconfig #get_netmask #set_gateway #set_ip_address #set_ip_mode #set_netmask 64 Commands #get_ip_address Displays the current IP address of the Sender or Receiver unit. Syntax #get_ip_address Parameters None Example #get_ip_address IP: 10.5.64.60 Related Commands #get_gateway #get_ip_mode #get_ipconfig #get_netmask #get_web_port #set_gateway #set_ip_address #set_ip_mode #set_netmask #set_web_port 65 Commands #get_ip_mode Displays the current IP mode. Syntax #get_ip_mode Parameters None Example #get_ip_mode IP MODE IS SET TO DHCP Related Commands #get_gateway #get_ip_address #get_ipconfig #get_netmask #get_web_port #set_gateway #set_ip_address #set_ip_mode #set_netmask #set_web_port 66 Commands #get_ipconfig Displays the current IP configuration. In addition to providing the MAC address and the broadcast IP address, this command also provides the same information as executing the #get_ip_mode, #get_ip_address, #get_netmask, and #get_gateway commands. Syntax #get_ipconfig Parameters None Example #get_ipconfig IP CONFIGURATION IS : IP MODE: DHCP IP: 10.5.64.60 NETMASK: 255.255.255.0 GATEWAY: 10.5.64.1 MAC ADDRESS: 00-1C-91-03-C8-B3 Related Commands #get_gateway #get_ip_address #get_netmask #get_web_port #set_gateway #set_ip_address #set_ip_mode #set_netmask #set_web_port 67 Commands #get_net_mode Displays the current network mode setting. Syntax #get_net_mode Parameters None Example #get_net_mode NETWORK MODE SET TO MULTICAST Related Commands #set_net_mode 68 Commands #get_netmask Displays the current net mask setting. Syntax #get_netmask Parameters None Example #get_netmask NETMASK: 255.255.255.0 Related Commands #get_gateway #get_ip_address #get_ipconfig #get_web_port #set_gateway #set_ip_address #set_ip_mode #set_netmask #set_web_port 69 Commands #get_remote_udp_access Displays the remote UDP access state. Syntax #get_remote_udp_access Parameters None Example #get_remote_udp_access REMOTE UDP ACCESS IS ENABLED Related Commands #get_remote_udp_ip #get_remote_udp_port #get_udp_access #get_udp_port #set_remote_udp_access #set_remote_udp_ip #set_remote_udp_port #set_udp_access #set_udp_port 70 Commands #get_remote_udp_ip Displays the remote UDP IP address. Syntax #get_remote_udp_ip Parameters None Example #get_remote_udp_access REMOTE UDP IP: 192.168.1.29 Related Commands #get_remote_udp_access #get_remote_udp_port #get_udp_access #get_udp_port #set_remote_udp_access #set_remote_udp_ip #set_remote_udp_port #set_udp_access #set_udp_port 71 Commands #get_remote_udp_port Displays the remote UDP listening port. Syntax #get_remote_udp_port Parameters None Example #get_remote_udp_port REMOTE UDP COMMUNICATIONS PORT: 50008 Related Commands #get_remote_udp_access #get_remote_udp_ip #get_udp_access #get_udp_port #set_remote_udp_access #set_remote_udp_ip #set_remote_udp_port #set_udp_access #set_udp_port 72 Commands #get_rx_channel Displays the current channel of the Receiver unit. To set the audio channel of a Receiver unit, use the #set_rx_id command. Syntax #get_rx_channel Parameters None Example #get_rx_channel RECEIVER CHANNEL: 1 Related Commands #get_tx_channel #set_tx_channel r 73 Commands #get_rx_id Displays the ID of the Receiver unit. This command is only available when connected to a Receiver unit. Syntax #get_rx_id Parameters None Example #get_rx_id RX ID: 8 Related Commands #set_rx_id 74 Commands #get_rx_mute Displays the audio mute feature state. Use the #set_rx_mute command to set enable/disable the audio mute feature. This command is only available when connected to a Receiver unit. Syntax #get_rx_mute Parameters None Example #get_rx_mute RX_MUTE 0 Related Commands #set_rx_mute 75 Commands #get_serial_allow Displays the Serial-over-IP state. Use the #set_serial_allow command to enable or disable the Serial-over-IP feature. Syntax #get_serial_allow Parameters None Example #get_serial_allow SERIAL OVER IP is ENABLE Related Commands #get_serial_baud #get_serial_parity #get_serial_stop #set_serial_allow #set_serial_baud #set_serial_bits #set_serial_parity #set_serial_stop 76 Commands #get_serial_baud Displays the serial baud rate setting. Use the #set_serial_baud command to set the baud rate. Syntax #get_serial_baud Parameters None Example #get_serial_baud SERIAL BAUD RATE IS 19200 Related Commands #get_serial_allow #get_serial_bits #get_serial_parity #get_serial_stop #set_serial_allow #set_serial_baud #set_serial_bits #set_serial_parity #set_serial_stop 77 Commands #get_serial_bits Displays the serial data bits setting. Use the #set_serial_bits command to set the number of data bits. Syntax #get_serial_bits Parameters None Example #get_serial_bits SERIAL DATA BITS IS 8 Related Commands #get_serial_allow #get_serial_baud #get_serial_parity #get_serial_stop #set_serial_allow #set_serial_baud #set_serial_bits #set_serial_parity #set_serial_stop 78 Commands #get_serial_parity Displays the serial parity bit setting. Use the #set_serial_parity command to set the parity bit. Syntax #get_serial_parity Parameters None Example #get_serial_parity SERIAL PARITY MODE SET TO NONE Related Commands #get_serial_allow #get_serial_baud #get_serial_bits #get_serial_stop #set_serial_allow #set_serial_baud #set_serial_bits #set_serial_parity #set_serial_stop 79 Commands #get_serial_stop Displays the serial stop bits setting. Use the #set_serial_stop command to set the number of stop bits. Syntax #get_serial_stop Parameters None Example #get_serial_stop SERIAL STOP BITS IS 1 Related Commands #get_serial_allow #get_serial_baud #get_serial_bits #get_serial_parity #set_serial_allow #set_serial_baud #set_serial_bits #set_serial_parity #set_serial_stop 80 Commands #get_showme Displays the showme state. Syntax #get_showme Parameters None Example #get_showme SHOW ME DISABLED Related Commands #set_showme 81 Commands #get_telnet_access Displays the Telnet access state. Use the #set_telnet_access command to enable or disable Telnet access. Syntax #get_telnet_access Parameters None Example #get_telnet_access TELNET ACCESS IS ENABLED Related Commands #get_telnet_login #get_telnet_port #get_telnet_welcome #set_telnet_access #set_telnet_pass #set_telnet_login #set_telnet_pass #set_telnet_port #set_telnet_welcome 82 Commands #get_telnet_login Displays the Telnet login status. Syntax #get_telnet_login Parameters None Example #get_telnet_login TELNET LOGIN SET TO DISABLED Related Commands #get_telnet_access #get_telnet_port #get_telnet_welcome #set_telnet_access #set_telnet_pass #set_telnet_login #set_telnet_pass #set_telnet_port #set_telnet_welcome 83 Commands #get_telnet_port Displays the Telnet listening port. Syntax #get_telnet_port Parameters None Example #get_telnet_port TELNET COMMUNICATION PORT: 23 Related Commands #get_telnet_access #get_telnet_login #get_telnet_welcome #set_telnet_access #set_telnet_pass #set_telnet_login #set_telnet_pass #set_telnet_port #set_telnet_welcome 84 Commands #get_telnet_welcome Displays the Telnet welcome message. Use the #set_telnet_welcome to create a custom welcome message. Syntax #get_telnet_welcome Parameters None Example #get_telnet_welcome TELNET WELCOME SCREEN IS DISABLED Related Commands #get_telnet_access #get_telnet_login #get_telnet_port #set_telnet_access #set_telnet_pass #set_telnet_login #set_telnet_pass #set_telnet_port #set_telnet_welcome 85 Commands #get_tx_channel Displays the audio channel of the Sender unit. This command is only available when connected to a Sender unit. Syntax #get_tx_channel Parameters None Example #get_tx_channel TRANSMITTER CHANNEL: 1 Related Commands #get_rx_channel #set_tx_channel r 86 Commands #get_udp_access Displays the UDP access state. Use the #set_udp_access command to enable or disable UDP access. Syntax #get_udp_access Parameters None Example #get_udp_access UDP ACCESS IS ENABLED Related Commands #get_remote_udp_access #get_remote_udp_ip #get_remote_udp_port #get_udp_port #set_remote_udp_access #set_remote_udp_ip #set_remote_udp_port #set_udp_access #set_udp_port 87 Commands #get_udp_port Displays the local UDP listening port. Syntax #get_udp_port Parameters None Example #get_udp_port UDP PORT SET TO 50007 Related Commands #get_remote_udp_access #get_remote_udp_ip #get_remote_udp_port #get_udp_access #set_remote_udp_access #set_remote_udp_ip #set_remote_udp_port #set_udp_access #set_udp_port 88 Commands #get_web_port Displays the HTTP listening port. Use the #set_web_port command to set the HTTP listening port. Syntax #get_web_port Parameters None Example #get_web_port WEB INTERFACE PORT: 80 Related Commands #get_gateway #get_ip_address #get_ipconfig #set_gateway #set_ip_address #set_ip_mode #set_netmask #set_web_port 89 Commands #reboot Reboots the Sender / Receiver unit. Syntax #reboot Parameters None Example #reboot UNIT WILL REBOOT SHORTLY Related Commands #factory_reset 90 Commands #set_clk_lock Sets the audio clock lock. This command is only available on the Receiver unit. After executing this command, the unit must be rebooted to apply the changes. Syntax #set_block param1 Parameters param1 Integer [0 ... 500] Example #set_clk_lock 100 PLEASE REBOOT THE UNIT TO APPLY CHANGES Related Commands #get_clk_lock 91 Commands #set_device_desc Sets the description for the Sender / Receiver unit. The description string cannot exceed 30 characters in length. Spaces and underscore characters are acceptable. Avoid using symbols and special characters. Syntax #set_description param1 Parameters param1 String Example #set_description Blu-ray_Panasonic PRODUCT DESCRIPTION SET Related Commands #get_device_desc 92 Commands #set_discovery Enables or disables the discovery feature. The default value is On. Syntax #set_discovery param1 Parameters param1 Integer [0 ... 1] param1 Description 0 Off 1 On Example #set_discovery 0 DISCOVERY SERVICE SET TO DISABLED Related Commands #get_discovery #set_showme #get_showme 93 Commands #set_discovery_mode Sets the discovery read / write mode. Syntax #set_discovery_mode param1 Parameters param1 Integer [0 ... 1] param1 Description 0 Read only mode 1 Read / write mode Example #set_discovery_mode 1 DISCOVERY MODE 1 Related Commands #get_edid_copy 94 Commands #set_gateway Sets the gateway address. This command is only applicable when using Static IP mode. param1 must be specified using dot-decimal notation. After executing this command, the unit must be rebooted to apply the changes. Syntax #set_gateway param1 Parameters param1 IP Address Example #set_gateway 192.168.1.1 GATEWAY ADDRESS SET TO 192.168.1.1 PLEASE REBOOT THE UNIT TO APPLY CHANGES Related Commands #get_gateway #get_ip_address #get_ip_mode #get_ipconfig #get_netmask #get_web_port #set_ip_address #set_ip_mode #set_netmask #set_web_port 95 Commands #set_ip_address Sets the IP address. param1 must be specified using dot-decimal notation. After executing this command, the unit must be rebooted to apply the changes. Syntax #set_ip_address param1 Parameters param1 IP Address Example #set_gateway 192.168.1.1 GATEWAY ADDRESS SET TO 192.168.1.1 PLEASE REBOOT THE UNIT TO APPLY CHANGES Related Commands #get_gateway #get_ip_address #get_ip_mode #get_ipconfig #get_netmask #get_web_port #set_gateway #set_ip_mode #set_netmask #set_web_port 96 Commands #set_ip_mode Sets the IP mode. After executing this command, the unit must be rebooted to apply the changes. Syntax #set_ip_mode param1 Parameters param1 Integer [0 ... 2] param1 Description 0 Static 1 2 DHCP Auto IP Example #set_ip_mode 1 IP MODE SET TO DHCP PLEASE REBOOT THE UNIT TO APPLY CHANGES Related Commands #get_gateway #get_ip_address #get_ip_mode #get_ipconfig #get_netmask #get_web_port #set_ip_address #set_gateway #set_netmask #set_web_port 97 Commands #set_net_mode Sets the network casting mode. Syntax #set_net_mode param1 Parameters param1 Integer [0 ... 1] param1 Description 0 Unicast 1 Multicast Example #set_net_mode 0 NETWORK CASTING MODE SET TO UNICAST Related Commands #get_net_mode 98 Commands #set_netmask Sets the network mask address. param1 must be specified using dot-decimal notation. After executing this command, the unit must be rebooted to apply the changes. Syntax #set_netmask param1 Parameters param1 IP Address Example #set_netmask 255.255.255.0 NETMASK ADDRESS SET TO 255.255.255.0 PLEASE REBOOT THE UNIT TO APPLY CHANGES Related Commands #get_gateway #get_ip_address #get_ip_mode #get_ipconfig #get_netmask #get_web_port #set_ip_address #set_ip_mode #set_gateway #set_web_port 99 Commands #set_remote_udp_access Enables or disables remote UDP access. After executing this command, the unit must be rebooted to apply the changes. Syntax #set_remote_udp_access param1 Parameters param1 Integer [0 ... 1] param1 Description 0 Disabled 1 Enabled Example #set_remote_udp_access 1 REMOTE UDP ACCESS SET TO ENABLED PLEASE REBOOT THE UNIT TO APPLY CHANGES Related Commands #get_remote_udp_access #get_remote_udp_ip #get_remote_udp_port #get_udp_access #get_udp_port #set_remote_udp_access #set_remote_udp_ip #set_remote_udp_port #set_udp_access #set_udp_port 100 Commands #set_remote_udp_ip Set the remote UDP IP address. param1 must be specified using dot-decimal notation. After executing this command, the unit must be rebooted to apply the changes. Syntax #set_remote_udp_ip param1 Parameters param1 IP address Example #set_remote_udp_ip 192.168.1.29 REMOTE UDP IP ADDRESS SET TO 192.168.1.29 PLEASE REBOOT THE UNIT TO APPLY CHANGES Related Commands #get_remote_udp_access #get_remote_udp_ip #get_remote_udp_port #get_udp_access #get_udp_port #set_remote_udp_access #set_remote_udp_port #set_udp_access #set_udp_port 101 Commands #set_remote_udp_port Set the remote UDP listening port. After executing this command, the unit must be rebooted to apply the changes. Syntax #set_remote_udp_port param1 Parameters param1 Integer [0 ... 65535] Example #set_remote_udp_port 50008 REMOTE UDP COMMUNICATIONS PORT IS SET TO PORT 50008 PLEASE REBOOT THE UNIT TO APPLY CHANGES Related Commands #get_remote_udp_access #get_remote_udp_ip #get_remote_udp_port #get_udp_access #get_udp_port #set_remote_udp_access #set_remote_udp_ip #set_udp_access #set_udp_port 102 Commands #set_rx_id Sets the ID of the Receiver unit. This command is only available when connected to a Receiver unit. Syntax #set_rx_id param1 Parameters param1 Integer [0 ... 65535] Example #set_rx_id 1 RX ID: 1 Related Commands #get_rx_id 103 Commands #set_rx_mute Enable or disable the audio mute feature. This command is only available when connected to a Receiver unit. Syntax #set_rx_mute Parameters param1 Integer [0 ... 1] param1 Description 0 Disable 1 Enable Example #set_rx_mute 0 RX_MUTE 0 Related Commands #get_rx_mute 104 Commands #set_serial_allow Enables or disables serial over IP. After executing this command, the unit must be rebooted to apply the changes. Syntax #set_serial_allow param1 Parameters param1 Integer [0 ... 1] param1 Description 0 Disable 1 Enable Example #set_serial_allow 0 SERIAL OVER IP SET TO DISABLED PLEASE REBOOT THE UNIT TO APPLY CHANGES Related Commands #get_serial_allow #get_serial_baud #get_serial_bits #get_serial_parity #get_serial_stop #set_serial_baud #set_serial_bits #set_serial_parity #set_serial_stop 105 Commands #set_serial_baud Sets the baud rate for the serial port. After executing this command, the unit must be rebooted to apply the changes. Syntax #set_serial_baud param1 Parameters param1 Integer [0 ... 9] param1 Description (baud rate) 0 300 1 2 3 4 5 6 7 8 Example 9 600 1200 2400 4800 9600 19200 38400 57600 115200 #set_serial_baud 6 SERIAL BAUD RATE SET TO 19200 PLEASE REBOOT THE UNIT TO APPLY CHANGES Related Commands #get_serial_allow #get_serial_baud #get_serial_bits #get_serial_parity #get_serial_stop #set_serial_allow #set_serial_bits #set_serial_parity #set_serial_stop 106 Commands #set_serial_bits Sets the data bits for the serial port. After executing this command, the unit must be rebooted to apply the changes. Syntax #set_serial_bits param1 Parameters param1 Integer [0 ... 3] param1 Description (data bits) 0 5 1 2 3 6 7 8 Example #set_serial_bits 3 SERIAL DATA BITS SET TO 8 PLEASE REBOOT THE UNIT TO APPLY CHANGES Related Commands #get_serial_allow #get_serial_baud #get_serial_bits #get_serial_parity #get_serial_stop #set_serial_allow #set_serial_baud #set_serial_bits #set_serial_parity #set_serial_stop 107 Commands #set_serial_parity Sets the parity bit for the serial port. After executing this command, the unit must be rebooted to apply the changes. Syntax #set_serial_parity param1 Parameters param1 Integer [0 ... 2] param1 Description 0 None 1 2 Odd Even Example #set_serial_parity 0 SERIAL PARITY MODE SET TO NONE PLEASE REBOOT THE UNIT TO APPLY CHANGES Related Commands #get_serial_allow #get_serial_baud #get_serial_bits #get_serial_parity #get_serial_stop #set_serial_allow #set_serial_baud #set_serial_bits #set_serial_stop 108 Commands #set_serial_stop Sets the number of stop bits for the serial port. After executing this command, the unit must be rebooted to apply the changes. Syntax #set_serial_stop param1 Parameters param1 Integer [0 ... 1] param1 Description (stop bits) 0 1 1 2 Example #set_serial_stop 0 SERIAL STOP BITS SET TO 1 PLEASE REBOOT THE UNIT TO APPLY CHANGES Related Commands #get_serial_allow #get_serial_baud #get_serial_bits #get_serial_parity #get_serial_stop #set_serial_allow #set_serial_baud #set_serial_bits #set_serial_parity 109 Commands #set_showme Enables or disables the “Show Me” feature. When the “Show Me” feature is enabled, then both the Power and Link LED indicators, on the front panel, will flash. This quickly identifies a unit and is useful when multiple units are being used. The default setting is disabled. Syntax #set_showme param1 Parameters param1 Integer [0 ... 1] param1 Description 0 Disabled 1 Enabled Example #set_showme 1 SHOW ME ENABLED Related Commands #get_discovery #set_discovery 110 Commands #set_telnet_access Enables or disables Telnet access. After executing this command, the unit must be rebooted to apply the changes. Syntax #set_telnet_access param1 Parameters param1 Integer [0 ... 1] param1 Description 0 Disabled 1 Enabled Example #set_telnet_access 1 TELNET ACCESS SET TO ENABLED PLEASE REBOOT THE UNIT TO APPLY CHANGES Related Commands #get_telnet_access #get_telnet_login #get_telnet_port #get_telnet_welcome #set_telnet_login #set_telnet_pass #set_telnet_port #set_telnet_welcome 111 Commands #set_telnet_login Enables or disables the Telnet login process. After executing this command, the unit must be rebooted to apply the changes. Syntax #set_telnet_login param1 Parameters param1 Integer [0 ... 1] param1 Description 0 Disabled 1 Enabled Example #set_telnet_login 1 TELNET INTERFACE LOGIN SET TO ENABLED PLEASE REBOOT THE UNIT TO APPLY CHANGES Related Commands #get_telnet_access #get_telnet_pass #get_telnet_port #get_telnet_welcome #set_telnet_access #set_telnet_pass #set_telnet_port #set_telnet_welcome 112 Commands #set_telnet_pass Sets the Telnet password. The password cannot exceed 8 characters in length and is casesensitive. No special characters are allowed. The default password is admin. After executing this command, the unit must be rebooted to apply the changes. Syntax #set_telnet_pass param1 Parameters param1 String Example #set_telnet_pass b055man TELNET INTERFACE PASSWORD IS SET b055man PLEASE REBOOT THE UNIT TO APPLY CHANGES Related Commands #get_telnet_access #get_telnet_pass #get_telnet_port #get_telnet_welcome #set_telnet_access #set_telnet_login #set_telnet_port #set_telnet_welcome 113 Commands #set_telnet_port Sets the Telnet listening port. After executing this command, the unit must be rebooted to apply the changes. Syntax #set_telnet_port param1 Parameters param1 Integer [0 ... 65535] Example #set_telnet_port 23 TELNET COMMUNICATIONS PORT SET TO PORT 23 PLEASE REBOOT THE UNIT TO APPLY CHANGES Related Commands #get_telnet_access #get_telnet_pass #get_telnet_port #get_telnet_welcome #set_telnet_access #set_telnet_login #set_telnet_pass #set_telnet_welcome 114 Commands #set_telnet_welcome Enables / disables the Telnet welcome screen. After executing this command, the unit must be rebooted to apply the changes. Syntax #set_telnet_welcome param1 Parameters param1 Integer [0 ... 1] param1 Description 0 Disabled 1 Enabled Example #set_telnet_welcome Welcome! TELNET WELCOME SCREEN IS ENABLED PLEASE REBOOT THE UNIT TO APPLY CHANGES Related Commands #get_telnet_access #get_telnet_pass #get_telnet_port #get_telnet_welcome #set_telnet_access #set_telnet_login #set_telnet_pass #set_telnet_port 115 Commands #set_tx_channel Sets the audio channel for the Sender unit. This command is only available when connected to the Sender unit. Syntax #set_tx_channel param1 Parameters param1 Integer [0 ... 255] Example #set_tx_channel 1 TRANSMITTER CHANNEL SET TO 1 Related Commands #get_tx_channel #get_rx_channel r 116 Commands #set_udp_access Enables or disables UDP access. After executing this command, the unit must be rebooted to apply the changes. Syntax #set_udp_access param1 Parameters param1 Integer [0 ... 1] param1 Description 0 Disabled 1 Enabled Example #set_udp_access 0 UDP ACCESS SET TO DISABLED PLEASE REBOOT THE UNIT TO APPLY CHANGES Related Commands #get_remote_udp_access #get_remote_udp_ip #get_remote_udp_port #get_udp_access #get_udp_port #set_remote_udp_access #set_remote_udp_ip #set_remote_udp_port #set_udp_port 117 Commands #set_udp_port Sets the local UDP listening port. After executing this command, the unit must be rebooted to apply the changes. Syntax #set_udp_port param1 Parameters param1 Integer [0 ... 65535] Example #set_udp_port 50007 UDP COMMUNCATION IS SET TO PORT 50007 PLEASE REBOOT THE UNIT TO APPLY CHANGES. Related Commands #get_remote_udp_access #get_remote_udp_ip #get_remote_udp_port #get_udp_access #get_udp_port #set_remote_udp_access #set_remote_udp_ip #set_remote_udp_port #set_udp_access 118 Commands #set_web_port Sets the HTTP listening port. Syntax #set_web_port param1 Parameters param1 Integer [0 ... 65535] Example #set_web_port 82 WEB INTERFACE PORT SET TO 80 PLEASE REBOOT THE UNIT TO APPLY CHANGES Related Commands #get_gateway #get_ip_address #get_ip_mode #get_ipconfig #get_netmask #get_web_port #set_gateway #set_ip_address #set_ip_mode #set_netmask 119 Commands #set_webui_ad_pass Sets the Administrator password for the Web interface login. The password cannot exceed eight characters in length. The default password is admin. Syntax #set_webui_ad_pass param1 Parameters param1 Password Example #set_webui_ad_pass b05Sman WEB UI ADMINISTRATOR PASSWORD IS SET Related Commands #set_webui_user_pass 120 Commands #set_webui_user_pass Sets the User password for the Web interface login. The password cannot exceed eight characters in length. The default password is user. Syntax #set_webui_user_pass param1 Parameters param1 Password Example #set_webui_user_pass m1ni0n WEB UI USER PASSWORD IS SET Related Commands #set_webui_ad_pass 121 Commands r Changes a Receiver unit to the specified audio channel. Changing the audio channel allows a Receiver unit to accept the signal from a Sender unit that uses the same audio channel. This command is only available when connected to a Receiver unit. Do not precede this command with the # symbol. Syntax r param1 Parameters param1 Integer [0 ... 255] Example r 1 TRANSMITTER 1 ROUTED TO RECEIVER Related Commands None 122 Network Cable Diagram Front of RJ-45 Connector 1 2 3 4 5 6 7 8 Gefen recommends the TIA/EIA-568-B wiring option. Use the table below when field-terminating cable for use with Gefen products. Pin Color Description 1 Orange / White TD+ (Transmit Data, positive differential signal) 2 Orange TD- (Transmit Data, negative differential signal) 3 Green / White RD+ (Receive Data, positive differential signal) 4 Blue Unused 5 Blue / White Unused 6 Green RD- (Receive Data, negative differential signal) 7 Brown / White Unused 8 Brown / White Unused Note Shielded CAT-5e (or better) cabling should be used.. 123 Rack Tray Installation The following illustrations provide instructions for installing the Sender and/or Receiver unit(s) in the Gefen 1U Rack Tray (Gefen part no. EXT-RACK-1U-GRY). Step 1 Turn unit upside down. Step 2 Remove rubber feet. Step 3 Line up holes on unit and rack tray. Step 4 Install countersink screws . Step 5 Ensure the unit is installed securely. Step 6 Unit has been installed into rack tray. 124 Specifications* Supported Formats Audio • Analog L/R Stereo, 2-Channel PCM, and up to 5.1 channels of Bitstream Audio In Connector (Sender) • 1 x 3.5mm mini-stereo, female Audio Out Connector (Receiver) • 1 x 3.5mm mini-stereo, female Opt In Connector (Sender) • 1 x TOSLINK® Opt Out Connector (Receiver) • 1 x TOSLINK® Coax In Connector (Sender) • 1 x RCA-type, female Coax Out Connector (Receiver) • 1 x RCA-type, female Link Connector (Sender / Receiver) • 1 x RJ-45, shielded Link PoE Connector (Sender / Receiver) • 1 x RJ-45, shielded RS-232 Connector (Sender / Receiver) • 1 x 3.5mm mini-stereo, female IR In/Ext Connector (Sender / Receiver) • 1 x 3.5mm mini-stereo, female IR Out Connector (Sender / Receiver) • 1 x 3.5mm mini-stereo, female Power Connector (Sender / Receiver) • 1 x 5V DC, locking, 5.5mm barrel/2.1mm pin Power Indicator (Sender / Receiver) • 1 x LED, blue Link Indicator (Sender / Receiver) • 1 x LED, green Power Consumption (maximum) • Sender: 3W, Receiver: 7W Operating Temperature • +32 to +122°F (0 to +50°C) Operating Humidity • 5% to 90% RH, non-condensing Storage Temperature • -4 to +185°F (-20 to +85°C) Storage Humidity (RH) • 0% to 95% RH, non-condensing MTBF • 50000 hours Dimensions (W x H x D) (Sender / Receiver), not including feet and connectors • 8.4” x 1.0” x 4.9” (214mm x 25mm x 123mm) Net Weight (Sender/Receiver) • 1.6 lbs. (0.72 kg) Connectors & Indicators Operational Physical * Features and specifications are subject to change without notice. All trademarks and registered trademarks are properties of their respective owners. Copyright© 2018 Nortek Security & Control, LLC 125 Nortek Security & Control, LLC 1800 S McDowell Blvd. Petaluma CA 94954, USA 1-707-283-5900 1-800-472-5555 Copyright© 2018 Nortek Security & Control, LLC Part Number: MAN-EXT-ADA-LAN
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Language : en-US Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.6-c143 79.161210, 2017/08/11-10:28:36 Create Date : 2018:03:22 16:26:07-07:00 Metadata Date : 2018:03:22 16:28:09-07:00 Modify Date : 2018:03:22 16:28:09-07:00 Creator Tool : Adobe InDesign CC 13.0 (Macintosh) Instance ID : uuid:b943888b-be9f-fd40-bfee-ce0ba5dfbfec Original Document ID : xmp.did:208FED43445CE211A75BEC20F72BF2CF Document ID : xmp.id:b27fea7b-2cb1-4351-8574-d504db5ea3db Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:2c882b0a-0c94-44e7-8a9f-759b42d3bf97 Derived From Document ID : xmp.did:2c882b0a-0c94-44e7-8a9f-759b42d3bf97 Derived From Original Document ID: xmp.did:208FED43445CE211A75BEC20F72BF2CF Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 13.0 (Macintosh) History Changed : / History When : 2018:03:22 16:26:07-07:00 Format : application/pdf Producer : Adobe PDF Library 15.0 Trapped : False Page Count : 126 Creator : Adobe InDesign CC 13.0 (Macintosh)EXIF Metadata provided by EXIF.tools