Maxell ME-M21 RFID Reader/Writer Module User Manual

Hitachi Maxell, Ltd. RFID Reader/Writer Module Users Manual

Contents

User Manual

Download: Maxell ME-M21 RFID Reader/Writer Module User Manual
Mirror Download [FCC.gov]Maxell ME-M21 RFID Reader/Writer Module User Manual
Document ID738260
Application IDHVs9X7zNrfEgq/FpMZN5Xg==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize25.95kB (324321 bits)
Date Submitted2006-12-14 00:00:00
Date Available2006-12-14 00:00:00
Creation Date2006-11-23 15:37:28
Producing SoftwareAcrobat Distiller 5.0.5 (Windows)
Document Lastmod2006-11-23 15:37:34
Document TitleUsers Manual
Document CreatorAcrobat PDFMaker 5.0 for Word
Document Author: “ú—§ƒ}ƒNƒZƒ‹\(Š”\)“dŽqƒfƒoƒCƒX

Manual
Reader/Writer Module
ME-MA21 (UART I/F)
ME-MR21 (RS232C I/F)
1. External Appearance
2. Application
3. Product Outline
4. Specifications
5. Receiving property parameters
6. Notices before use
7. Notes in handling
8. Notes in operating
FCC WARNING
ME-MA21/MR21
Coil-on-Chip RFID
External Appearance
Reader/Writer module
Antenna
100±20mm
ME-MA21
MR21
150±20mm
ME-MR21
50.0±0.5mm
34.6±0.5mm
ME-CK21
MA21
Antenna cable
18.8±0.5mm
Where model name
65.0±0.5mm
14.2mm(max)
label is affixed.
7.0mm(max)
MAXELL SEIKI CONFIDENTIAL
ME-MA21/MR21
Coil-on-Chip RFID
Application
These specifications are applicable to the reader/writer modules for RFID: ME-MA21 and ME-MR21
that are delivered by Maxell Seiki, Ltd. (referred to as Maxell hereafter), to SEGA Corporation (referred
to as SEGA hereafter) by way of Kaga Devices Co., Ltd.
Product outline
3.1
Outline of ME-MA21 (UART I/F)
The ME-MA21 is used in a reader/writer module for RFID that performs data communication with a
host system using UART I/F (CMOS level I/F), by connecting the device to equipment prepared by
SEGA. Applicable RFID chips are ME-Y2000 series products (1Kbyte/2Kbyte/4Kbyte), which perform
data processing by radio communication with RFID chip incorporated in a card.
The following provides circuit block diagram of the ME-MA21 module:
3.2
Outline of ME-MR21 (RS232C I/F)
The ME-MR21 is used in a reader/writer module for RFID that performs data communication with a
host system using RS232C I/F (RS232C level I/F), by connecting the device to equipment prepared by
SEGA. Applicable RFID chips are ME-Y2000 series products (1Kbyte/2Kbyte/4Kbyte), which perform
data processing by radio communication with RFID chip incorporated in a card.
The following provides circuit block diagram of the ME-MR21 module:
MAXELL SEIKI CONFIDENTIAL
ME-MA21/MR21
Coil-on-Chip RFID
Specifications
4.1
Environmental performances
No
4.2
Item
Operating temperature range
Operating humidity range
Storage temperature range
Storage humidity range
Specifications
0 ~ 50°C
20 ~ 80%RH (No condensation)
-10 ~ 60°C
20 ~ 80%RH (No condensation)
Physical specifications
・Reader/Writer module
No
Item
Outer dimensions
Material of board
Weight
Specifications
50.0mm (D) x 65.0mm (W) x 14.2mm (H: max.)
Glass epoxy FR-4
Approximately 32g
・Antenna module
No
Item
Outer dimensions
Material of board
Weight
MAXELL SEIKI CONFIDENTIAL
Specifications
18.8mm (D) x 34.6mm (W) x 7.0mm (H: max.)
Glass epoxy FR-4
Approximately 2g
ME-MA21/MR21
4.3
・MA21
Electrical performance
Item
Power supply voltage
Current consumption
Carrier frequency
Data rate
Communication
quality*
Carrier on/off ratio
・MR21
Coil-on-Chip RFID
Item
Power supply voltage
Current consumption
Carrier frequency
Data rate
Communication quality*
Carrier on/off ratio
Specifications
4.75~5.25 V
1) Max. 700mA
Operating condition: Primary condition is turning-on carrier.
2) Max. 110mA
Idle 1 and Idle 2 conditions: Primary condition is turning-off carrier.
13.56MHz±15ppm or lower
212kbps
-Communicating distance: 0.7 to 2.2mm
-Allowable transverse displacement (width direction): ±1.0mm/vertcal
displacement (length direction): ±2.0mm (from antenna board to
antenna side of RFID chip on board)
-Communication of only one card
1) When communicating, adjust an amplifier gain at an optimum level on
the host system.
2) Do not install any parts of metal or magnetic material around the
antenna.
Ratio of on status: 50% or lower
Specifications
4.75~5.25 V
1) Max. 900mA
Operating condition: Primary condition is turning-on carrier.
2) Max. 110mA
Idle 1 and Idle 2 conditions: Primary condition is turning-off carrier
13.56MHz±15ppm or lower
212kbps
-Communicating distance: 1.0 to 2.2mm (communicating using one card)
1.0 to 1.6mm (communicating using two cards)
(from antenna board to antenna side of RFID chip on board)
-Allowable transverse displacement (width direction): ±1.0mm/vertcal
displacement (length direction): ±2.0mm
1) When communicating, adjust an amplifier gain at an optimum level on
the host system.
2) Do not install any parts of metal or magnetic material around the
antenna.
Ratio of on status: 50% or lower
* Values in the table above are provided for reference purpose only. The values fluctuate according
to actual system environments. Perform evaluation on an actual system environment, and adjust
communication distance, gain settings, and transverse displacement for secure communication.
The “communication distance” above refers to a distance between an antenna-coil surface of RFID
chip and a R/W antenna coil. A distance between an RFID chip package surface and a R/W
antenna coil is shorter than the values above as much as a thickness of package.
MAXELL SEIKI CONFIDENTIAL
ME-MA21/MR21
Coil-on-Chip RFID
4.4
4.4.1
Pin
Interface specifications
CN101 connector pin alignment (host)
Pin name
Function
GND
GND(0V)
TXD
Data output
RXD
Data input
Remarks
Direction
-
Ground
Output
Sending data signal (output)
Input
Receiving data signal (input)
(Connected to Vcc on board)
RFID chip presence/absence signal
/DETECT
Presence/absence of
chip
Present: /DETECT=0
Input
Absent: /DETECT=1
/DETECT=1 is applicable when “not used.”
(Pull-up with 1kΩ on board)
Antenna power supply control signal
/ANTPWR
Antenna power
Input
ON:
/ANTPWR=0
OFF:
/ANTPWR=1
Fixed to /ANTPWR=0 when “not used.”
(Pull-up with 1kΩ on board)
System reset signal
/RESET
Reset signal
Input
Reset:
/RESET=0
Other than Reset:
/RESET= open
/RESET is opened for “not used.”
4.4.2
Pin
VCC
+5V power supply
-
CN102 connector pin alignment (antenna)
Pin name
Function
VANT
Antenna power supply
GND
GND
SIGNAL
Analog signal
MAXELL SEIKI CONFIDENTIAL
Remarks
Direction
Output
Input
Core wire
Shielded wire side
Core wire
ME-MA21/MR21
Coil-on-Chip RFID
RXD/TXD communication specifications
4.4.3
Item
Specifications
Communication rate
(real rate *1)
19,200 bps(18,750 bps)*2
38,400 bps(37,500 bps)
Communication mode
RS232C half duplex
Synchronous mode
Asynchronous
Flow control
None
Number of start bits
1bit
Number of data bits
8bit
Number of stop bits
1bit
Number of parity bits
bit/even
*1: The controller installed on this module uses a 6MHz oscillator. Because a communication
rate is generated by frequency division of the oscillator, actual rates of this module are
values in parentheses.
*2: A communication rate upon turning on the power (system resetting) is 19,200bps.
MAXELL SEIKI CONFIDENTIAL
ME-MA21/MR21
Coil-on-Chip RFID
5 Receiving property parameters
This setting is very important for stable reading and writing processings. Optimum receiving property
parameter values vary depending on communication characteristics of individual RFID chips and
positional relationship between the R/W antenna and the RFID chip. When communicating with
another RFID chip or after re-positioning the components (including removing and inserting a card), be
sure to optimize the receiving property parameters to agree with the receiving property of the RFID
chip.
Parameters to be optimized are slice level and gain. Switching of gain only also can optimize the
characteristics to some degree. To optimize the system more fitting to the using environments,
optimize the parameters in combination with a slice level.
Specify a comparator slice level using higher-order bits b7 to b4 (4 bits) of the receiving property
parameter. Also, specify an amplifier gain using lower-order bits b 3 to b0 (4 bits) of the parameter. The
following provides receiving property parameter setting registers and parameter values.
bit
Reset
values
7~4
Function
Slice level selecting bit
D: Low
E: High
Receiving gain
selecting bit
3~0
0: 14dB
1: 16dB
2: 18dB
3: 20dB
4: 22dB
5: 24dB
6: 26dB
7: 28dB
8: 30dB
9: 32dB
A: 34dB
B: 36dB
C: 38dB
D: 40dB
E: 42dB
F: 44dB
- Example of adjusting receiving property parameters
Find a gain setting that causes the least communication errors in product development and evaluation
stage, and set the value as default. In addition, provide software processing that automatically
fine-tunes the gain values upward and downward.
In consideration of operating conditions (power supply voltages and ambient temperatures), variation
of communicating distance, and variation of communicating performances of RFID chip, tuning the
gain in 1-LSB steps upward and downward is recommended.
For details, refer to the application notes.
Example: Setting values in lower 8 bits of receiving property parameter setting register:
Default “EA”→EB→E9→EC→E8→ED→E7→EE→E6→EF→E5 (→Return to default)
(Repeat several retries at each gain level.)
MAXELL SEIKI CONFIDENTIAL
ME-MA21/MR21
Coil-on-Chip RFID
Notices before use
・ R The R/W module may not comply with the Electro Magnetic Interference (EMI) Standards by
itself.
Provide appropriate EMI measures on a system according to customer’s application and use.
・ For safety purposes, provide protective measures on the host against overcurrent of a power
supply due to short circuit in components of this product.
・ Do not place a metal object between the R/W module and the RFID chip. Place the antenna away
from conductive objects such as a metal frame. ME-CK21 antenna must be placed 30mm or more
away from such objects. Placing a conductive object near the antenna may deteriorate
communication property.
Notes in handling
・ When handling the module, remove static electricity from human body. Do not drop, bump, bend, or give a
shock to the module.
Notes in operating
・ Be sure to use Maxell’s ME-Y2000 series RFID chip (ME-Y2001/ME-Y2002/ME-Y2004). Using
other chips may cause malfunction or destruction of circuits.
・ A slow-start power supply circuit is installed on the R/W module for protection against rush
currents. After changing /ANTPWR=1 into /ANTPWR=0 (shutdown), wait for at least 2 seconds
before starting communication with a RFID chip.
・ Perform sufficient evaluations on user environments and communicating distances and perform
correct adjustment on receiving gain property parameters in accordance with user’s
environments.
・ Be sure to adjust receiving gain property parameters by host control. Upon retrying after
communication error, re-adjust gain.
・ After terminating required communication, issue a carrier OFF command (CARRIER_OFF
command). Continuing operation under carrier ON status causes heating of RFID chip and
deformation of the package.
・ Specify an interval of switching carrier-OFF into carrier-ON to be twice or more of a previous
carrier-sending period. For safety purpose, a carrier is terminated in approximately 40 seconds
after starting transmission of a carrier (Protection status) .
・ To release the Protection status, issue a RESET command or turn off the power and then turn it
on again.
・ When inserting and removing connectors on the R/W module, turn off the power. Inserting and
removing connectors with power on may cause damage to circuits.
MAXELL SEIKI CONFIDENTIAL
Coil-on-Chip RFID
ME-MA21/MR21
●FCC WARNING
Changes or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
Notice:
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
-Reorient or relocate the receiving antenna
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
We, the manufacturer (Maxell Seiki, Ltd.) hereby declare that this equipment (RFID
Reader/Writer Module), model ME-MA21-A-SNT/ME-MR21-A-SG is in compliance with the
essential requirements and other relevant provisions of Directive 1999/5/EC.
evant provisions of Directive 1999/5/EC.
MAXELL SEIKI CONFIDENTIAL

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Modify Date                     : 2006:11:23 15:37:34+09:00
Create Date                     : 2006:11:23 15:37:28+09:00
Page Count                      : 11
Creation Date                   : 2006:11:23 06:37:28Z
Mod Date                        : 2006:11:23 06:37:28Z
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Author                          : “ú—§ƒ}ƒNƒZƒ‹\(Š”\)“dŽqƒfƒoƒCƒX
Metadata Date                   : 2006:11:23 06:37:28Z
Title                           : ƒf[ƒ^ƒV[ƒg
Creator                         : “ú—§ƒ}ƒNƒZƒ‹\(Š”\)“dŽqƒfƒoƒCƒX
Page Mode                       : UseNone
Tagged PDF                      : Yes
EXIF Metadata provided by EXIF.tools
FCC ID Filing: UOEME-M21

Navigation menu