Maxitrol R300 Electronic remote control system User Manual Microsoft PowerPoint

Maxitrol Company Electronic remote control system Microsoft PowerPoint

User manual

Maxitrol Company
Confidential 1
User manual
Maxitrol Company
Confidential
Maxitrol Company
Confidential 2
User manual
-Handset Models -
• Standard
• Display
• Thermostatic
Maxitrol Company
Confidential 3
Operational Specification
-Handset Models -
Display and
Thermostatic
Model
Maxitrol Company
Confidential 4
Operational Specification
- Handset Models and Corresponding Icons Used -
X
X
X
X
X
X
X
X
Thermostatic
Model
X
X
X
X
X
X
Display
Model
M2, M3, M4, M5, 1J
S1, S2, S3, S4, S5
T1, T2
T3
S6
1A to 1K, 1L, 2A to 2L,
3A to 3L, 4A to 4L, AM,
PM
B1, B2, B3, B4
M1
5A to 5L, 6A to 6L, °F,
°C
Corresponding LCD
Segments
LCD Icon
X
Communication Indicator
Timer1 and Timer2 Indicators
Setpoint Indicator (SP bars)
Sleep Mode Indicator
Enhanced Communication Indicator
Clock
Battery Indicator
X
Child-safety Lock
Standard
Model
Corresponding Feature
X
Temperature
Maxitrol Company
Confidential 5
Operational Specification
-“
Standard” -
None
When Rx receives the stop-
command, flame height knob stops
turning; and LED turns off
When Rx receives the increase-
flame command, LED turns on; and
flame height knob continuously
turns counterclockwise
When Rx receives the stop-
command, flame height knob stops
turning; and LED turns off
When Rx receives the decrease-
flame-command, LED turns on; and
flame height knob continuously
turns clockwise
None
Result seen on the receiver(Rx)
Communication indicator turns off;
and Tx sends ONE stop-command
Up button is released
Communication indicator turns off;
and Tx sends ONE stop-command
Down button is released
Programming
Active
Idle
Tx Operation Result seen on the Handset(Tx)Action Taken
ALL icons turn off and it enters
programming mode
Press and hold for 10
seconds both buttons
Room temperature is updated
continuously; and Child-safety Lock
is displayed if selected
No buttons are being
pressed
Communication indicator light up in
sequence(see above); and Tx sends
ONE increase-flame-command
Up button is pressed
Communication indicator light up in
sequence(M2-5,1J); and Tx sends
ONE decrease-flame-command
Down button is pressed
Note: To increase flame while child-lock is on, user needs to make 2 consecutive UP button presses within half a second. Doing so will
increase the flame but will not disable the child-lock. To decrease flame while child-lock is on, only one DOWN button press is required.
Maxitrol Company
Confidential 6
Operational Specification
-“Standard”-
When Rx receives the decrease-
flame-command, Rx continuously
turns the flame height knob
clockwise until knob
reaches limit and then it stops
Tx sends ONE decrease-flame-
command to Rx
Auto-pilot
After 8 hours of being in
continuous Sleep Mode
None
Result seen on the receiver(Rx)
Sleep
Tx Operation Result seen on the Handset(Tx)Action Taken
Tx goes to sleep, and ONLY the sleep
mode indicator is on
After 120 minutes of
being in continuous Idle
Mode
Maxitrol Company
Confidential 7
Operational Specification
-“Standard” Menu Structure -
After the UP and
DOWN buttons
are pressed for
10 seconds:
°F (blinking)
Child-safety lock (blinking)
Press UP button to
display: Press DOWN button
to scroll through the
options:
After 15s of
inactivity the
handset will
save
changes and
return to
normal
operation. Child-safety lock is on or off
°F or °C (blinking)
Maxitrol Company
Confidential 8
Operational Specification
-“Display”-
None
When Rx receives the stop-
command, flame height knob stops
turning; and LED turns off
When Rx receives the increase-
flame command, LED turns on; and
flame height knob continuously
turns counterclockwise
When Rx receives the stop-
command, flame height knob stops
turning; and LED turns off
When Rx receives the decrease-
flame-command, LED turns on; and
flame height knob continuously
turns clockwise
None
Result seen on the receiver(Rx)
Enhanced communication indicator
turns off; and Tx sends ONE stop-
command
Up button is released
Enhanced communication indicator
turns off; and Tx sends ONE stop-
command
Down button is released
Programming
Active
Idle
Tx Operation Result seen on the Handset(Tx)Action Taken
All icons turn off and it enters
programming mode
Press and hold for 10
seconds both buttons
Room temperature is updated
continuously; Child-safety Lock is
displayed if selected; Clock and battery
indicators are updated every second;
and COL icon flashes every second
No buttons are being
pressed
Enhanced communication indicator
turns on; and Tx sends ONE increase-
flame-command
Up button is pressed
Enhanced communication indicator
turns on; and Tx sends ONE decrease-
flame-command
Down button is pressed
Note: To increase flame while child-lock is on, user needs to make 2 consecutive UP button presses within half a second. Doing so will
increase the flame but will not disable the child-lock. To decrease flame while child-lock is on, only one DOWN button press is required.
Maxitrol Company
Confidential 9
Operational Specification
-“Display”-
When Rx receives the decrease-
flame-command, Rx continuously
turns the flame height knob
clockwise until knob reaches
limit and then it stops
Tx sends ONE decrease-flame-
command to Rx
Auto-pilot
After 8 hours of being in
continuous Sleep Mode
None
Result seen on the receiver(Rx)
Sleep
Tx Operation Result seen on the Handset(Tx)Action Taken
Tx goes to sleep, and ONLY the sleep
mode indicator is on
After 120 minutes of
being in continuous Idle
Mode
Maxitrol Company
Confidential 10
Operational Specification
-“Display” Menu Structure -
After the UP and
DOWN buttons
are pressed for
10 seconds:
°F (blinking)
“12h” (blinking)
(hh) (blinking)
Child-safety lock (blinking)
Press UP button to
display: Press DOWN button
to scroll through the
options:
“24h” or “12h”(blinking)
1-12 or 0 -23 (blinking)*
00 -59 (blinking)*
After 15s of
inactivity the
handset will
save
changes and
return to
normal
operation.
(mm) (blinking)
Child-safety lock is on or off
°F or °C (blinking)
*Prolonged button press will result in a
progressively faster scrolling rate (up to
10 increments/s)
Rev.A
Maxitrol Company
Confidential 11
Operational Specification
- “Thermostatic” -
The Thermostatic model can operate in one of three modes:
0:00 23:59T1, START T1, STOP T2, START T2, STOP
SP2 SP1 SP2 SP2SP1
Manual Mode:
Behaves as the “Display” Model. User has control of flame height via two buttons.
Automatic Mode:
User has control of the setpoint via two buttons.
Automatic mode will send increase or decrease commands to the receiver at random intervals to achieve a
temperature at the handset equal to the current setpoint.
Timer Mode:
User has control of the current setpoint via two buttons. Timer mode behaves as the Automatic Mode.
There are two programmable timers (T1and T2) each with a start and stop time that together span one 24
hour period.
There are two setpoints (SP1 and SP2) that correspond to “timer on” and “timer off”. When either of the two
timers are on, SP1 is current otherwise SP2 is current. (see diagram below)
SP2 cannot be set higher than SP1.
0:00 23:59T2, STOP T1, START T1, STOP T2, START
SP1 SP2 SP1 SP1SP2
Rev.A
Maxitrol Company
Confidential 12
Operational Specification
- “Thermostatic” -
Manual
Automatic
Timer
Idle
Active
Programming
Sleep
Auto-pilot
Active
Active
Programming
Programming
If the UP and
DOWN buttons
are pressed:
SP bars are displayed
(Thermostatic Mode)
SP bars, T1 and T2 are off
(Manual Mode)
Press UP and DOWN buttons and
release them immediately to
switch between the 3 modes:
SP bars are displayed, and T1 or
T2 are on
(Timer Mode)
In summary the 3 modes are: The 3 modes are entered by:
51°F set point < 61°F
40°F set point < 51°F
SP bars: Indicate the range in
which the set point is at:
61°F set point < 71°F
71°F set point < 81°F
81°F set point < 99°F
Rev.A
Maxitrol Company
Confidential 13
Operational Specification
-“Thermostatic”-
See slides 8 and 9
Mode
None
Rx waits for
command
from Tx
Rx waits for
command
from Tx
Rx waits for
command
from Tx
Result seen
on the
receiver(Rx)
Programming
Active
Tx Operation Result seen on the Handset(Tx)Action Taken
All icons turn off and it enters programming
mode
Press and hold for 10
seconds both buttons
Room temperature is updated continuously;
Child-safety Lock is displayed if selected; Clock
and battery indicators are updated every second;
COL icon flashes every second; Tx
automatically adjusts the flame at a random
interval so as the keep the room temperature at
the set temperature; and SP bars are displayed.
No buttons are being
pressed
Set point is increased by 1°; and SP bars are
updated
Up button is pressed
Set point is decreased by 1°; and SP bars are
updated
Down button is pressed
Automatic Manual
Note: To increase flame or SP while child-lock is on, user needs to make 2 consecutive UP button presses within half a second. Doing so will
increase the flame/SP but will not disable the child-lock. To decrease flame while child-lock is on, only one DOWN button press is required.
Maxitrol Company
Confidential 14
Operational Specification
-“Thermostatic”-
Rx waits for
command
from Tx
SP2 is decreased by 1°; and SP bars are
updated
Down button is pressed
while T1/T2 is off (SP2 is
active)
Rx waits for
command
from Tx
SP2 is increased by 1°; and SP bars are
updated
Up button is pressed
while T1/T2 is off (SP2 is
active)
Mode
None
Rx waits for
command
from Tx
Rx waits for
command
from Tx
Rx waits for
command
from Tx
Result seen
on the
receiver(Rx)
Programming
Active
Tx Operation Result seen on the Handset(Tx)Action Taken
All icons turn off and it enters programming
mode
Press and hold for 10
seconds both buttons
Room temperature is updated continuously;
Child-safety Lock is displayed if selected; Clock
and battery indicators are updated every second;
COL icon flashes every second; Tx
automatically adjusts the flame at a random
interval so as the keep the room temperature at
the current set temperature; either SP1 or SP2
is active; T1, T2 or T3 is on and SP bars are
displayed
No buttons are being
pressed
SP1 is increased by 1°; and SP bars are
updated
Up button is pressed
while T1/T2 is on (SP1 is
active)
SP1 is decreased by 1°; and SP bars are
updated
Down button is pressed
while T1/T2 is on (SP1 is
active)
Timer
Note: To increase flame or SP while child-lock is on, user needs to make 2 consecutive UP button presses within half a second. Doing so will
increase the flame/SP but will not disable the child-lock. To decrease flame while child-lock is on, only one DOWN button press is required.
Maxitrol Company
Confidential 15
Operational Specification
- “Thermostatic” Menu Structure -
After 15s of
inactivity the
handset will save
changes and return
to normal operation.
“12h” (blinking)
(hh) (blinking)
(mm) (blinking)
°F (blinking)
Press UP button to display: Press DOWN button to scroll
through the options:
1-12 or 0 -23 (blinking)*
00 -59 (blinking)*
“24h” or “12h” (blinking)
The temperature digits are
blinking, display “on” using the
clock digits, and “T1” and “T2”
are on
°C or °F (blinking)
Child-lock (blinking) Child-lock is on or off
After the UP and
DOWN buttons
are pressed for
10 seconds:
40-99 (blinking)*SP1
*Prolonged button press will result in a
progressively faster scrolling rate (up to
10 increments/s)
Rev.A
Maxitrol Company
Confidential 16
Operational Specification
- “Thermostatic” Menu Structure -
After 15s of
inactivity the
handset will save
changes and return
to normal operation.
T1, STOP
T2, START
T2, STOP
“--” denotes off, or turn the valve closed
until the lower limit switch is reached.
“T1” on and (hh:mm)
blinking
Display (SP1 and T1) T1, START
0:00, 0:15 - 23:45 or
12:00am, 12:15am-11:45pm
(blinking)*
The temperature digits are
blinking, display “off” using the
clock digits, and T3 is on
--, 40-99 (blinking)*SP2
0:00, 0:15 - 23:45 or
12:00am, 12:15am-11:45pm
(blinking)*
“T1” and (hh:mm) blinking
Display (SP1)
“T2” on and (hh:mm)
blinking
Display (SP1 and T2)
“T2” and (hh:mm) blinking
Display (SP1)
0:00, 0:15 - 23:45 or
12:00am, 12:15am-11:45pm
(blinking)*
0:00, 0:15 - 23:45 or
12:00am, 12:15am-11:45pm
(blinking)*
*Prolonged button press will result in a
progressively faster scrolling rate (up to
10 increments/s)
Rev.A
Maxitrol Company
Confidential 17
Note 1 :
This device complies with EMC Directive 89/336/EEC,
Low Voltage Directive 76/23/EEC and
R&TTE Directive 1995/5/EEC.This product has been
approved for upper directives and covers
the following countries : Austria Belgium Cyprus Czech
Republic Denmark Estonia Finland
France Germany Grecce Hungary Ireland Italy Lativa
Lithuania Luxembourg Malta Poland
Portugal Slovakia Slovenia Spain Sweden The
Netherlands UK Iceland Norway
Switerland Turkey Romania
Maxitrol Company
Confidential 18
Note 2 :
15.21 “Changes or modifications are not
expressly
approved by the manufacturer could void the
user's authority to operate the equipment.”
"Operation is subject to the following two
conditions: (1) this device may not cause
interference,
and (2) this device must accept any interference,
including interference that may cause undesired
operation of the device."

Navigation menu