Maxitrol R300 Electronic remote control system User Manual Microsoft PowerPoint
Maxitrol Company Electronic remote control system Microsoft PowerPoint
Maxitrol >
User manual
User manual Maxitrol Company Confidential Maxitrol Company Confidential User manual - Handset Models • Standard • Display • Thermostatic Maxitrol Company Confidential Operational Specification - Handset Models - Display and Thermostatic Model Maxitrol Company Confidential Operational Specification - Handset Models and Corresponding Icons Used LCD Icon Corresponding LCD Segments Corresponding Feature Standard Model Display Model Thermostatic Model 5A to 5L, 6A to 6L, °F, °C Temperature M1 Child-safety Lock B1, B2, B3, B4 Battery Indicator 1A to 1K, 1L, 2A to 2L, 3A to 3L, 4A to 4L, AM, PM Clock S6 Enhanced Communication Indicator T3 Sleep Mode Indicator T1, T2 Timer1 and Timer2 Indicators S1, S2, S3, S4, S5 Setpoint Indicator (SP bars) M2, M3, M4, M5, 1J Communication Indicator Maxitrol Company Confidential Operational Specification - “Standard” Note: To increase flame while child-lock is on, user needs to make 2 consecutive UP button presses within half a second. Doing so will increase the flame but will not disable the child-lock. To decrease flame while child-lock is on, only one DOWN button press is required. Action Taken Tx Operation Result seen on the Handset(Tx) Result seen on the receiver(Rx) Idle Room temperature is updated continuously; and Child-safety Lock is displayed if selected None Down button is pressed Communication indicator light up in sequence(M2-5,1J); and Tx sends ONE decrease-flame-command When Rx receives the decreaseflame-command, LED turns on; and flame height knob continuously turns clockwise Down button is released Communication indicator turns off; and Tx sends ONE stop-command When Rx receives the stopcommand, flame height knob stops turning; and LED turns off Up button is pressed Communication indicator light up in sequence(see above); and Tx sends ONE increase-flame-command When Rx receives the increaseflame command, LED turns on; and flame height knob continuously turns counterclockwise Up button is released Communication indicator turns off; and Tx sends ONE stop-command When Rx receives the stopcommand, flame height knob stops turning; and LED turns off ALL icons turn off and it enters programming mode None No buttons are being pressed Active Press and hold for 10 seconds both buttons Maxitrol Company Confidential Programming Operational Specification - “Standard” Action Taken After 120 minutes of being in continuous Idle Mode After 8 hours of being in continuous Sleep Mode Maxitrol Company Confidential Tx Operation Result seen on the Handset(Tx) Result seen on the receiver(Rx) Sleep Tx goes to sleep, and ONLY the sleep mode indicator is on None Tx sends ONE decrease-flamecommand to Rx When Rx receives the decreaseflame-command, Rx continuously turns the flame height knob clockwise until knob reaches limit and then it stops Auto-pilot Operational Specification - “Standard” Menu Structure Press UP button to display: After 15s of inactivity the handset will save changes and return to normal operation. Press DOWN button to scroll through the options: After the UP and DOWN buttons are pressed for 10 seconds: Maxitrol Company Confidential °F (blinking) °F or °C (blinking) Child-safety lock (blinking) Child-safety lock is on or off Operational Specification - “Display” Note: To increase flame while child-lock is on, user needs to make 2 consecutive UP button presses within half a second. Doing so will increase the flame but will not disable the child-lock. To decrease flame while child-lock is on, only one DOWN button press is required. Action Taken Tx Operation Result seen on the Handset(Tx) Result seen on the receiver(Rx) Idle Room temperature is updated continuously; Child-safety Lock is displayed if selected; Clock and battery indicators are updated every second; and COL icon flashes every second None Down button is pressed Enhanced communication indicator turns on; and Tx sends ONE decreaseflame-command When Rx receives the decreaseflame-command, LED turns on; and flame height knob continuously turns clockwise Down button is released Enhanced communication indicator turns off; and Tx sends ONE stopcommand When Rx receives the stopcommand, flame height knob stops turning; and LED turns off Up button is pressed Enhanced communication indicator turns on; and Tx sends ONE increaseflame-command When Rx receives the increaseflame command, LED turns on; and flame height knob continuously turns counterclockwise Up button is released Enhanced communication indicator turns off; and Tx sends ONE stopcommand When Rx receives the stopcommand, flame height knob stops turning; and LED turns off All icons turn off and it enters programming mode None No buttons are being pressed Active Press and hold for 10 seconds both buttons Maxitrol Company Confidential Programming Operational Specification - “Display” Action Taken After 120 minutes of being in continuous Idle Mode After 8 hours of being in continuous Sleep Mode Maxitrol Company Confidential Tx Operation Result seen on the Handset(Tx) Result seen on the receiver(Rx) Sleep Tx goes to sleep, and ONLY the sleep mode indicator is on None Tx sends ONE decrease-flamecommand to Rx When Rx receives the decreaseflame-command, Rx continuously turns the flame height knob clockwise until knob reaches limit and then it stops Auto-pilot Operational Specification - “Display” Menu Structure Press UP button to display: Press DOWN button to scroll through the options: After the UP and DOWN buttons are pressed for 10 seconds: After 15s of inactivity the handset will save changes and return to normal operation. Maxitrol Company Confidential °F (blinking) °F or °C (blinking) “12h” (blinking) “24h” or “12h”(blinking) (hh) (blinking) 1-12 or 0 -23 (blinking)* (mm) (blinking) 00 -59 (blinking)* Child-safety lock (blinking) Child-safety lock is on or off *Prolonged button press will result in a Rev.A progressively faster scrolling rate (up to 10 increments/s) 10 Operational Specification - “Thermostatic” The Thermostatic model can operate in one of three modes: • Manual Mode: – • Automatic Mode: – – • Behaves as the “Display” Model. User has control of flame height via two buttons. User has control of the setpoint via two buttons. Automatic mode will send increase or decrease commands to the receiver at random intervals to achieve a temperature at the handset equal to the current setpoint. Timer Mode: – – – User has control of the current setpoint via two buttons. Timer mode behaves as the Automatic Mode. There are two programmable timers (T1 and T2) each with a start and stop time that together span one 24 hour period. There are two setpoints (SP1 and SP2) that correspond to “timer on” and “timer off”. When either of the two timers are on, SP1 is current otherwise SP2 is current. (see diagram below) SP2 cannot be set higher than SP1. 0:00 T1, START SP2 0:00 T1, STOP SP1 T2, STOP SP1 Maxitrol Company Confidential T2, START SP2 T1, START SP2 T2, STOP SP1 T1, STOP SP1 23:59 SP2 T2, START SP2 23:59 SP1 Rev.A 11 Operational Specification - “Thermostatic” In summary the 3 modes are: The 3 modes are entered by: Idle Active Manual Programming If the UP and DOWN buttons are pressed: Press UP and DOWN buttons and release them immediately to switch between the 3 modes: SP bars, T1 and T2 are off (Manual Mode) Sleep Auto-pilot Active Automatic Programming Active Timer SP bars are displayed (Thermostatic Mode) SP bars are displayed, and T1 or T2 are on (Timer Mode) SP bars: Indicate the range in which the set point is at: Rev.A Programming 81°F ≤ set point < 99°F 71°F ≤ set point < 81°F 61°F ≤ set point < 71°F Maxitrol Company Confidential 51°F ≤ set point < 61°F 40°F ≤ set point < 51°F 12 Operational Specification - “Thermostatic” Action Taken Manual Mode Tx Operation Result seen on the receiver(Rx) See slides 8 and 9 Room temperature is updated continuously; Child-safety Lock is displayed if selected; Clock and battery indicators are updated every second; COL icon flashes every second; Tx automatically adjusts the flame at a random interval so as the keep the room temperature at the set temperature; and SP bars are displayed. Rx waits for command from Tx Down button is pressed Set point is decreased by 1°; and SP bars are updated Rx waits for command from Tx Up button is pressed Set point is increased by 1°; and SP bars are updated Rx waits for command from Tx All icons turn off and it enters programming mode None No buttons are being pressed Automatic Result seen on the Handset(Tx) Active Press and hold for 10 seconds both buttons Programming Note: To increase flame or SP while child-lock is on, user needs to make 2 consecutive UP button presses within half a second. Doing so will increase the flame/SP but will not disable the child-lock. To decrease flame while child-lock is on, only one DOWN button press is required. Maxitrol Company Confidential 13 Operational Specification - “Thermostatic” Note: To increase flame or SP while child-lock is on, user needs to make 2 consecutive UP button presses within half a second. Doing so will increase the flame/SP but will not disable the child-lock. To decrease flame while child-lock is on, only one DOWN button press is required. Result seen on the Handset(Tx) Result seen on the receiver(Rx) No buttons are being pressed Room temperature is updated continuously; Child-safety Lock is displayed if selected; Clock and battery indicators are updated every second; COL icon flashes every second; Tx automatically adjusts the flame at a random interval so as the keep the room temperature at the current set temperature; either SP1 or SP2 is active; T1, T2 or T3 is on and SP bars are displayed Rx waits for command from Tx Down button is pressed while T1/T2 is on (SP1 is active) SP1 is decreased by 1°; and SP bars are updated Rx waits for command from Tx Up button is pressed while T1/T2 is on (SP1 is active) SP1 is increased by 1°; and SP bars are updated Rx waits for command from Tx Down button is pressed while T1/T2 is off (SP2 is active) SP2 is decreased by 1°; and SP bars are updated Rx waits for command from Tx Action Taken Timer Mode Tx Operation Active SP2 is increased by 1°; and SP bars are updated Up button is pressed while T1/T2 is off (SP2 is active) Press and hold for 10 seconds both buttons Maxitrol Company Confidential Programming All icons turn off and it enters programming mode Rx waits for command from Tx None 14 Operational Specification - “Thermostatic” Menu Structure Press UP button to display: Press DOWN button to scroll through the options: After the UP and DOWN buttons are pressed for 10 seconds: After 15s of inactivity the handset will save changes and return to normal operation. °F (blinking) °C or °F (blinking) “12h” (blinking) “24h” or “12h” (blinking) (hh) (blinking) 1-12 or 0 -23 (blinking)* (mm) (blinking) 00 -59 (blinking)* Child-lock (blinking) Child-lock is on or off The temperature digits are blinking, display “on” using the clock digits, and “T1” and “T2” are on 40-99 (blinking)* SP1 Rev.A *Prolonged button press will result in a Maxitrol Company Confidential progressively faster scrolling rate (up to 10 increments/s) 15 Operational Specification - “Thermostatic” Menu Structure - After 15s of inactivity the handset will save changes and return to normal operation. “T1” on and (hh:mm) blinking Display (SP1 and T1) 0:00, 0:15 - 23:45 or 12:00am, 12:15am-11:45pm (blinking)* T1, START “T1” and (hh:mm) blinking Display (SP1) 0:00, 0:15 - 23:45 or 12:00am, 12:15am-11:45pm (blinking)* T1, STOP “T2” on and (hh:mm) blinking Display (SP1 and T2) 0:00, 0:15 - 23:45 or 12:00am, 12:15am-11:45pm (blinking)* T2, START “T2” and (hh:mm) blinking Display (SP1) 0:00, 0:15 - 23:45 or 12:00am, 12:15am-11:45pm (blinking)* T2, STOP The temperature digits are blinking, display “off” using the clock digits, and T3 is on Maxitrol Company Confidential --, 40-99 (blinking)* SP2 Rev.A *Prolonged button press will result in a “--” denotes off, or turn the valve closed until the lower limit switch is reached. progressively faster scrolling rate (up to 10 increments/s) 16 Note 1 : • This device complies with EMC Directive 89/336/EEC, Low Voltage Directive 76/23/EEC and • R&TTE Directive 1995/5/EEC.This product has been approved for upper directives and covers • the following countries : Austria Belgium Cyprus Czech Republic Denmark Estonia Finland • France Germany Grecce Hungary Ireland Italy Lativa Lithuania Luxembourg Malta Poland • Portugal Slovakia Slovenia Spain Sweden The Netherlands UK Iceland Norway • Switerland Turkey Romania Maxitrol Company Confidential 17 Note 2 : • 15.21 “Changes or modifications are not expressly • approved by the manufacturer could void the user's authority to operate the equipment.” • "Operation is subject to the following two conditions: (1) this device may not cause interference, • and (2) this device must accept any interference, including interference that may cause undesired operation of the device." Maxitrol Company Confidential 18
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0.5 (Windows) Create Date : 2008:03:04 14:30:28+08:00 Creator Tool : PScript5.dll Version 5.2 Modify Date : 2008:03:04 14:30:28+08:00 Format : application/pdf Title : Microsoft PowerPoint - User manual.ppt Creator : MIS Document ID : uuid:f5ca023a-7a6c-4acf-ab68-48df14772e64 Instance ID : uuid:bec4bf65-354a-41c8-ba51-20440ed2a240 Page Count : 18 Author : MISEXIF Metadata provided by EXIF.tools