STACKED

WASHER-

INSTALLATION

IMPORTANT

DRYER

INSTRUCTIONS

TO INSTALLER

REMOVE THE DOOR FROM ALL DISCARDED
APPLIANCES
SUCH AS DRYERS
AND COMBINATION
WASHER/DRYERS
TO AVOID THE DANGER OF A CHILD
SUFFOCATING
SHOULD HE/SHE CRAWL INSIDE AND THE DOOR BE SHUT.
TIIE DRYER MUST NOT BE INSTALLED
OR STORED
WILL BE EXPOSED TO WATER ANI)/OR WEATHER.

IN AN AREA WHERE

IT

US MODELS
PLEASE READ THE FOLLOWING
1FNSTRUCTIONS CAREI_q.ILLY
STARTING TO INSTALL THE DRYER.
FOR GAS DRYERS, THE
MUST CONFORM
WITH THE NATIONAL FUEL GAS CODE ANSI
EST REVISION.
ANY QUESTIONS
CONCERNING
THIS SHOULD
TO THE LOCAL GAS UTILITY.

MA'_IAG

A_mlral 7t

_,Je_N-_

BEFORE
INSTALLATION
Z223.1, LATBE REFERRED

4V_

C._f

C_s_omer
Se_i_0

__

240 EdwardsStreet,SE
Cleveland,Tennessee3731;
Te!: 423-472-3333
Fax:423-478-6710

IMPORTANT

TO OWNER

Retain these instructions for future reference.
This new Maytag appliance is designed to serve you dependably for many years. However,
it cannot do so unless provided with sufficient electrica! power, suitable exhausting and if a
gas model, adequate gas supply. We urge you to read this carefully to make sure all
requirements are met.
Operating instructions,
safety precautions and your warranty are in the accessory
with each appliance.
Read the operating instructions carefully.

package

NOTE: A wiring diagram for the dryer is located on the inside of the dryer access panel.
wiring diagram for the washer is located on the inside of the washer front panel.

A

LrNCRATING

To remove carton, cut around bottom of carton on or below dotted line. Cut down each
corner of carton (vertically) and "peel" carton away from stacked washer/dryer.
Fold carton
material for removal.
Check the unit for shipping damage.

The control cable for the washer is taped to the rear of the dryer stand at the bottom.
Remove tape from control cable and temporarily place end of control cable in dryer vent.
From the back of the Stacked Washer/Dryer,
grasp the dryer and stand, Pull dryer and stand
back and off of washer and shipping base. As dryer and stand are pulled back, carefully drop
dryer stand rear legs to the floor before clearing shipping base. (Do not drop dryer and stand
off of shipping base!).

_] M,\'_rAG

Admiral71

=_=mJENN-A;_

"_la_ic

C,,_ef

2a8 EdwardsStreet.SE
Cleveland,Tennessee37311
Tel: 423472-3333
Fax:423-478-6710

\

Untape and open washer lid. Remove installation accessory package, fill hoses and drain
hose and close lid. Leave tub block in place until installation is complete.
Be sure to remove
tub block after installation is complete and before use.!
Using the carton corner posts stacked in pairs, lay the washer on the posts on the left side.
Remove the crate base wires from the carton base. Use pliers or screwdriver to pry wires
from wood. (Do not kick the shipping base off of the washer).

Run the washer rear legs all the way up into the rear corner brackets and lock in place by
tightening lock nuts. Leave the front legs loose for leveling in a following step.
Install vinyl feet on the washer legs.
With the washer laying down, check belt tension and motor track freedom.
Lay a piece of
the shipping cardboard along the bottom edge of the cabinet and stand the washer back up.
(The cardboard protects the lower edge at the cabinet and the floor when standing the washer
back up).

NOTE: With the rear washer legs adjusted up, cabinet corner brackets in the rear can touch
and damage floor if caution is not used when moving washer
The dryer and stand are installed first.
Necessary electrical, gas, (if gas stacked
washer!dryer)
and vent connections are made as dryer and stand are put in position
eled. Let's first look at what facilities are needed.

.'¢V_£AG

Admirai

7!

_'nn_._N.._

_Magic

and lev-

C,het

_ustomer .....

o

i ,,Jl :_1"_jl,,,_ml,

4TA_,,i.,ir" _

2aOEdwardsS_e:. SE
Cleveland,Tennessee37311
Tei:423-_72-3332
Fax:_23-_78-87i0

PREINSTALLATION

CONSIDERATIONS

Location:
The stacked washer/dryer
is approved for zero clearance installation on the sides
and the back (depending on venting used). The location selected must take into consideration
the dimensions of the unit and convenience for customer use and access in case service should
be needed. The floor must be capable at supporting the weight of the unit (approximately
340 pounds) plus water (approximately
130 pounds) and be stable enough to prevent excessive vibration in spin cycles. A floor which is adequate for the standard washer is sufficient
for the stacked washer/dryer.
The following specifications and drawings show dimensions and locations
minal block (electric dryer) gas inlet (gas dryer) and drain outlet.

STACKED

WASHER

AND DRYER

Basic Dimensions 27 1/2" W x 27 1/2" D x 73" H (rain). See drawings
dimensions.
Uncrated Weight: Approximately
340 pounds.
KEY FACTS
Capacity:
Water

Standard

(16 gallons)

(full cycle) - 36 (30 Imp.) gal: 136 liters - large
30 (25 Imp.) gal: 114 liters - medium
24 (20 Imp.) gal: 91 liters - small

Motor:
!/2 H.P, rated; 115 volt; 60 Hz; reversible; thermoprotected
automatic reset. Model LDE7804 available in 220-240 volt; to Hz.
0.1 - 0.17

Hose Lengths:
Installation
120 p.s.i.
electrical
Uncrated

for complete

- WASHER

Usage:

Power:

of fill valve, ter-

kwh depending

on cycle.

Inlet 5 feet (1.52 m); drain 4 feet (t.22 m).

Requirements:
(2.11-8.44
outlet

against overload;

kg/cm)

properly

Weight:

Hot and cold water
range;

grounded

connections

120F to 140F
and protected

Approximately

340

_AG

hot water;

with water
a drain;

pressure
a t20

volt,

within
60Hz

by a 15 amp fuse.

pounds.

Admiral

7|

"JmmnlJENN-AJi:t

"_lc!lgiC

C,"l_|

30-

_x

igOUllqj

24GEdwardsStreet, SE
Cleve!and,Tennessee373!;
Tei: 423472-3333
Fax:423-47g-67t0

KEY

Air

FACTS

Flow:

Exhaust:
ductwork.
Dryer

180 cubic

feet per minute.

4 inch (t0.2 cm) duct permits a maximum
of 50 feet (15.4 m) rigid aluminum
Subtract
8 feet (2.44 m) for each 90 degree elbow and 8 feet for an exhaust
hood.

vented

Motor:

!/4

Export

Model

Heat

- DRYER

Source:

out of the back.
H.P.

rated;

- Model

115 volt;
LDE7804

60 Hz;

thermoprotected

available

in 220-240

against

overload;

automatic

volt; 50 Hz.

ELectric - Nichrome
helix coil, 240 volt 3-wire, 4600 watts, 30 amp
Gas - Single port burner;
18,000 BTU/hr;
electric ignition;
automatic

fuse.
shut-off.

13_
34.9

96.5 cm

73"
185.4cm

Note: Recessed
69.9 cm
back panel permits
flush-to-wall installation.

MAYrA6

27_I£
69.9 cm

.&dm|rai tJ

reset.

m.J_N-,_Jg

_ _tacjm ¢,',_'

240 EdwardsStreet,SE
C!eveland,Tenressee37311
TeJ:423-472-3333
Fax:422-478-67!0

ALCOVE

OR CLOSET

INSTALLATION

When the stacked washer/dryer is to be installed in an alcove area or a closet, clearance
should be provided around the unit for an adequate air supply and for ease of installation and
servicing. An appliance installed in a closet shall have no other fuel burning appliance
installed in the same closet, such as gas furnace, water heater or space heater, etc.
The dryer must be exhausted to the outside to minimize excessive lint accumulation and to
maintain good drying. We recommend allowance for more clearance than the minimum
installation clearances as shown.

\
36

Sq. I

Openin_

J

Each opening area must have a minimum of 36 square inches. These openings must not be
obstructed.
(Louvered door with equivalent air opening is acceptable).

MOBILE

HOME

INSTALLATION

Installation of Maytag dryers certified by the American Gas Association and bearing a label
stating they are suitable for installation in mobile homes, when installed in mobile homes,
must conform to the Manufactured Home Construction and Safety Standard Title 24 CFR,
part 32-80.
When installing a dryer in a mobile home, provisions for anchoring the dryer should be
made. An anchor bracket kit is available, Part No, 303740 to fasten dryer stand to floor.
Instructions for installing the anchor brackets are contained in each kit.
All mobile home installations

must be exhausted

to the outside with the exhaust duct termi-

nation securely fastened to the mobile home structure, using materials that will not support
combustion.
Exhaust the dryer using flexible metal exhausting materials and locate in an area
that provides adequate make-up air. The exhaust duct may not terminate beneath the mobile
home.

:S

240 EdwardsStreet,SE
C[eveland,Tennes.-_ee
.!7311
Tel:422-472-33._
Fax:423-478-57_0

MAKE

- UP AIR

For proper operation of the dryer unit, it is important to make sure the location has adequate
make-up air. This is especially important in any confined area such as a bathroom or closet.
There must be at least two 36 inch square unobstructed openings for intake air. This can be a
louvered door or other equivalent opening.
On gas dryer units in particular, adequate clearance as noted on the dryer minimum clearance
label should be maintained to insure enough air for combustion and proper operation of the
dryer. The area where located must not obstruct the flow of combustion or ventilating air.
When installing a Maytag Stacked Washer/Dryer the following minimum clearances to combustible surfaces must be maintained; clearance to wall and sides, 0 inches, top, 6 inches,
front 1/2 inch to washer, rear 0 inches with an outside exhaust, 4 inches with an inside
exhaust (not recommended). See Exhausting Section and Installation Accessories for exhaust
kits.

SERVICE

ACCESS

Location should allow access to the foot at the unit for washer and dryer service. Access
must be available to two screws at the top front corners of the dryer front panel (on the top).

240EdwardsS:raet,S£
Cleveland,Tensessee37_11
TeI: 423-472-$333
Fax:423-478-67"3

EXHAUSTING

The free air flow rate is approximately 180 cubic feet per minute. The vent system carries
lint and moisture away and to the outside. The length of the venting and the number of
elbows affect the air flow rate and the efficiency of the exhaust system.
DO NOT EXHAUST DRYER INTO ANY WALL, CEILING, CRAWL SPACE OR A
CONCEALED
SPACE OF A BUILDING, VENT CONNECTION,
GAS VENT OR
CHIMNEY.
THIS COULD CREATE A FIRE HAZARD FROM LINT EXPELLED
BY
THE DRYER.
FOR THE SAME I_ASON,
WE RECOMMEND
ONLY METAL
EXHAUST DUCT TO MINIMIZE RESTPdCTED AIR FLOW AND RELIABLY INSURE
THE CONTAINMENT
OF EXHAUST AIR, HEAT AND LINT. NEVER INSTALL A
SCREEN OVER EXHAUST OUTLET.
NEVER USE PLASTIC OR OTHER COMBUSTIBLE DUCTWORK.
AT LEAST ONCE A YEAR, INSPECT AND CLEAN INTE_OR
OF DUCTWORK.
FREQUENTLY
CHECK AND CLEAN VENT HOOD TO ASSURE
PROPER OPERATION.
A clothes dryer produces combustible lint and the area around the clothes dryer should be
kept free of lint. DO NOT STORE FLAMAVlABLE LIQUIDS OR MATERIALS
NEAR
A DRYER.

It is recommended that a dryer be exhausted to the outside using 4" rigid or flexible metal
ducting.
When located in a bedroom, bathroom or closet, the dryer must be exhausted to the outside.
The stacked washer/dryer
can only be exhausted
to accept the exhaust from the dryer.

out the back.

A 4" vent should be installed

To permit sufficient air circulation under the exhaust hood, there should be no less than a 12"
clearance between the bottom of the exhaust hood and the ground.
When possible the
exhaust hood should not exhaust directly into a window well. DO NOT terminate exhaust
under a building.
NOTE: Where the exhaust hood is to be installed
necessary to cut the hole.

through masonry,

a special masonry

saw is

Install the exhaust hood and secure with screws to the outside wall and seal with caulking
compound.

2_0 EdwardsStreet SE
Cieveiand.Tennessee57311
Tel: -:23-472-L333
Fax:423-478-6710

DIRECT

EXHAUST

An exhaust hood positioned to line up with the dryer exhaust pipe can be installed directly
through an outside wall. This would be the shortest and most direct exhaust method.
To exhaust up, route standard 4" diameter ducting up the recess and in the cabinet back using
the furnished retaining strap an screws to get nearly flush to walt installation.
To exhaust to
the side or down, install the furnished 4" long duct with four "S" clips to the inner dryer
exhaust, then use standard 4" ducting. This will position the dryer about 4 1/2" away from
the wall. Flush to wall side exhausting may be done by going above the dryer before going
sideways.
When exhausting down, wallboard can be removed from the wail to get the dryer closer to
the wall by placing the exhaust pipe between the studs. Check local codes for required
exhaust clearances.
Install ductwork from the dryer to exhaust hood. All joints must be made so exhaust end of
one pipe is inside the intake end of the next pipe. On flexible metal ductwork, all joints
should be secured with a 304630 clamp. DO NOT use sheet metal screws when assembling
rigid ducting.
Joints should taped.

FLEXIBLE

DUCTWORK

LIMITATIONS

Flexible metal ductwork should not exceed 34' of straight 4" ducting. The exhaust hood is
equivalent to 8' of duct and each 90 degree bend is equivalent to 8'. As an example if an
exhaust hood is used and two 90 degree bends, the maximum straight run would be 10'.
NOTE:
straight
hood.

If the radius
run.

No more

of a bend
than three

with 4" duct is 12" or greater,
90 degree

bends

should

the bend

can be considered

a

be used in any run with an exhaust

If flexible metal exhaust ducting is used, cut a short piece (about 3") off the male end of a 4"
diameter metal duct pipe. The short extension can be secured to the dryer exhaust with the
clips and the flexible metal duct can be clamped to the short extension.

.,3

240 EdwardsStreet, SE
C;eve!and,Tennessee373tl
Te_:422-472-3333
Fax:423-478-67t0

RIGID

DUCTWORK

LIMITATIONS

Rigid metal ductwork should not exceed 50' of straight 4" duct. Each 90 degree elbow and
the exhaust hood should be considered equivalent to 8' of straight ductwork.
For example, if an
duct allowed would
rigid ductwork run
between 90 degree

exhaust hood and two 90 degree elbows are used, the maximum straight
be 26'. Not more than three 90 degree elbows should be used in any
with an exhaust hood. Four feet of straight duct should be allowed
elbows

240 EdwardsStreet,SE
Cleveland,7e"nessee37311
Tel: 423-472-$333
Fax:423-478-,3710

ELECTRICAL

OBSERVE

ALL NATIONAL

ELECTRICAL

REQUIREMENTS

ELECTRICAL
AND
ORDINANCES

CODES,

SERVICE - 120 VOLTS,
WASHER-GAS
DRYER

LOCAL

CODES

60 HZ ONLY

A 120 volt, 60 Hz, 15 ampere fused eIectrical supply is required.
An individual branch (or
separate) circuit serving only this appliance is recommended.
DO NOT USE AN EXTENSION CORD unless it meets all requirements as outlined for grounding, polarizing (3-wire)
and capacity.
Wire size should be at least No. 14.

BEFORE OPERATING OR TESTING,
tion.

GROUNDING
IMPORTANT

follow grounding instructions in Grounding Sec-

- 120 VOLTS,
SAFETY

60 HZ

PRECAUTIONS

WARNING - To prevent unnecessary risk of fire, electrical shock or personal injury, all
wiring and grounding must be done in accordance with the National Electrical Code
ANSI/NFPA,
No.70, Latest Revision and local codes and ordinances.
It is the personal
responsibility and obligation of the appliance owner to provide adequate electrical service for
this appliance.
ELECTRICAL

GROUND

IS REQUIRED

MA'_.rAG

Admiral tt

ON

THIS

APPLIANCE

_n'n_JENN-ZJ_

"_gie

Cbet

240 EdwarusStree[,SE
Ueve]and,Tennessee37311
feF: _23-472-3333
Fax:423-_78-67_0

GROUNDING

INSTRUCTIONS

i

F

This appliance must be grounded. In the event of malfunction or breakdown, grounding will
reduce the risk of electric shock by providing a path of least resistance for electric current.
This appliance is equipped with a cord having an equipment-grounding conductor and a
grounding plug. The plug must be plugged into an appropriate outlet that is properly
grounded in accordance with all local codes and ordinances.

DANGER - Improper connection of the equipment-grounding conductor can result in a risk
of electric shock. Check with a qualified electrician or serviceman if you are in doubt as to
whether the appliance is properly grounded.
Do not modify the plug provided with the appliance.
proper outlet installed by a qualified electrician

ADDITIONAL

GROUND

PROCEDURE

- WHE_

If it will not fit the outlet, have a

LOCAL

CODE PERMITS.

An external ground wire, clamp and screws are provided for assistance in meeting local
codes. Where approved, it is recommended
this additional ground be installed.
A suitable
external ground connection MUST be determined prior to wire hookup.
Consult local building officials and qualified electrician in the event any questions exist.
NEVER CONNECT GROUND
HOT WATER PIPES.

WIRE TO PLASTIC

PLUMBING

LINES,

ALL GROUNDING
AND WIRING MUST BE DONE IN ACCORDANCE
NATIONAL
AND LOCAL CODES.

[]

_V;fAG

Admira|

]|

8,.,;ENN-.a41:I

_l_']llagic

GAS OR

WITH

C,'_e|

240 EdwardsStreet.SE
CJeveiand,Tennessee37311
Tel:423-472-3333
Fax:423-478-5710

ELECTRIC

DRYER

GROUNDING

UNITS

INSTRUCTIONS

This electric dryer must be connected to a ground metal, permanent wiring system; or an
equipment grounding conductor must be run with the circuit conductors and connected to the
equipment grounding terminal on the back panel.

Electric models are shipped with a ground strap connected from the neutral (P2) terminal
block post to the frame of the dryer. The use of this strap is permitted by the national electrical code. The dryer electrical supply may be connected by means of a new U.L. Listed
power supply cord kit rated at 240 volts minimum, 30 amperes with three No. 10 copper
wire conductors terminated with closed loop terminals, open end spade lugs with turned up
ends or with tinned leads.

Pt"

P2

-P3
Strain

Relief

f"

The power cord must be marked for use with a clothes dryer and be retained with suitable
strain relief. If the dryer is to be installed in a mobile home or an area where local codes do
not permit grounding through neutral, only a 4 conductor power cord, rated and terminated
as above, may be used.
The electrical supply circuit should be fused through a 30 amp fuse or circuit breaker on both
sides of the line. The neutral line of the service cord must always be connected to the P2
terminal post. The two hot lines of the service cord go to the PI and P3 terminal block
posts. The neutral should not be fused or broken.
Be sure terminal block nuts are tight and
replace access cover.
Canadian

models are shipped with approved

MA'fi_AG

power cord sets attached.

Admiral

71

=dE.._r,4-,._l

_llagic

Che!

240 EdwardsStreet,SE
Cleveiand,Tennessee37311
Tek 423472-3333
Fax:423-478-8710

G.F.I.
If the electric dryer is protected by a GROUND
cedure for a 4-wire hookup below.

4-WIRE

FAULT

INTERRUPTER,

follow the pro-

RECEPTACLE

The frame of a 120/240 Volt machine must NOT be connected to neutral terminals. It
MUST be connected to the 4th wire (green of the power supply) or to the metallic covering
of a three-wire supply.

If a 4-wire receptacle of NEMA type is used, a matching UL Listed power supply cord (pigtail) must be used. This cord contains four NO. 10 copper conductors with spade or ring
terminals on the dryer end. The 4th (grounding) conductor must be identified by a green
cover and the neutral conductor by a white cover. The cord should have a suitable strain
relief and should be a minimum of 4 feet long. The poser supply cord and strain relief are
not provided with the dryer.

MA'_rAG

Admtrai

TI

_l_,JeNN.,_m

"-_'_'_lagic C_'_et

240Edwards Street.SE
Cleveland,Tennessee37311
Tei:423-z72-3333
Fax:423-478-67"0

4-WIRE

SYSTEM

1. Remove

CONNECTIONS

the terminal

block cover.

2. Remove the ground strap from the ground screw and center (silver colored) terminal of
the terminal block.
3. Connect the neutral (white) wire of the power supply cord to the center (silver colored)
terminal of the terminal block. Connect the grounding (green) wire of the cord to the external ground connector, sing the green screw.
4. connect

the other two wires of the cord to the outer terminals of the terminal

block.

5. Replace the terminal block cover.

208 VOLT OPERATION
A 306378
operation.

kit is used to convert the electric microprocessor
stacked washer/dryer
A new heater element label and instructions are included.

The elctrical

mechanical

stacked washer/dryer

MA*_£\G

is not available

Admiral

I1

_,_.,ad_

for 208 volt

for 208 volt operation.

.¥ Jd.-aqic e_t

240EdwardsStreet,SE
CIeveian&Te£_essBe;7311
1el: 423-472-,3333
Fax:423-478-6710

WATER

SUPPLY

WATER

SUPPLY

AND DRAIN

The water supply to the washer unit should be capable of providing both adequate water
pressure and water temperature. The pressure should fall within the range of 30 pounds per
square inch to 120 pounds per square inch when the washer is filling. Note that this is flow
pressure and not static pressure. Low water pressure will result in slow fill and could result
in a water valve sticking open after a fill.
The temperature of the hot water as delivered to the washer should be 140 degrees F. The
temperature of the cold water as delivered to the washer should be 75 degrees F.
Warm water temperature is a result of the mix of the hot and cold water supplies. The final
temperature is dependent on both the pressure and the temperatures of the hot and cold supplies. The desired temperature for warm is between 100 degrees F and 105 degrees F.

DRAIN

FACILITIES

Because of the desirability of flush to the wall installation of the stacked washer/dryer,
drain directly behind the unit is preferred to a drain located on either side.

a

The washer unit is equipped with a built-in siphon break which allows for a variance in
height of the drain facility. The drain must be capable of accepting a flow rate of approximately 20 gallons per minute. An inside diameter of at least 1" - 1 l/2" is required.
The portion of the drain hose from the siphon break to the drain can be extended
drain. Consult the parts catalog for extra drain hose as needed.
The use of a laundry built-in wall box can greatly simplify

_'_ MA'zrAG

Admiral

!|

installation

_OENN-AIR

to a floor

of the unit.

_,_'_giC

¢_|

240 EdwardsStreet, SE
Cleveiand,TennesseeZ7311
Tel:423-472-3333
Fax:423-478-6710

Models are available that incorporate water supply, water drain, 120 Volt AC and 240 Volt
AC connections. An example is shown.

O

©
O

\
If the faucets and!or drain is located to either side of the stacked washer/dryer,
openings
located in the dryer stand uprights to allow hoses and power cords to be passed through.
This is to allow installation against the back wall. (This is dependent on venting used.)

[]

_'_-vfr,',.G

Admiral

YI

m.JeNN-aJR

"_Magic

Chef

are

240EdwardsStreet, SE
Creveianct,Tennessee37311
Tel: 423-47"2-3333
Fax:423-478-6710

GAS CONNECTION

Gas operated dryers are equipped with a burner orifice for operation on NATURAL gas. If
the dryer is to be operated on LP gas, it must be converted correctly for safety and proper
performance.
Conversion kits from NATURAL to LPG or LPG to NATURAL are available
through your local Maytag dealer. If other conversions are required, check with local gas
utility for specific information concerning conversion requirements.
NOTE:
The conversion should always be performed by a qualified service technician.

A 1/2" gas supply line is recommended and must be reduced to connect to the 3/8" gas line
on the dryer.
NOTE: A 3/8" x 2" pipe nipple is included to adapt valve connection from a 3/8" female to
a 3/8" male I.P.S. connection.
Additionally, a 1/8" N.P.T. (National Pipe Thread) plugged tapping, accessible for test
gauge connection, must be installed immediately upstream of the gas supply connection to the
dryer. Refer to your local gas utility or plumbing contractor should you have questions on
the installation of the plugged tapping.
The dryer and its individual shut-off valve must be disconnected from the gas supply piping
system during any pressure testing of the system at test pressures in excess of 1/2 P.S.I.G.
The dryer must be isolated from the gas supply piping system by closing its individual
manual shut-off valve during any pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 P.S.I.G.

Gas Line
Dryer

118"' NPT Plug

Gas Line

The gas supply should be connected to the dryer using pipe joint compound or a Teflon tape
on male thread connections.
NOTE:
Any pipe joint compound used must be resistant to the
action of any liquefied petroleum gas.

J

MA_£_G

Admiral

11

_E_N-,._

"_Maqic

Chef

CustomerSe_ic_

_'__

240 EGwardsStreet, SE
Cleveland,Tennessee3731;
Tel: :t23-472-3333
Fax:_23-478-67t0

Turn on gas supply and open the shutoff at the gas valve. Check all gas connections for leaks
using a soap solution. If bubbles occur, tighten connections and recheck. DO NOT use an
open flame to check for gas leaks.
NOTE:
As a courtesy, many local gas utilities will inspect a gas appliance
Check with your utility to see if this service is provided in your area.

installation.

NOTE: The minimum permissible gas (natural or mixed) supply pressure for purposes in
input adjustment is 4.5 inches of water.

GAS

IGNITION

This dryer uses an automatic ignition system to light the main burner when the dryer is
turned on.
If a 4-wire receptacle of NEMA type is used, a matching UL Listed power supply cord (pigtail) must be used. This cord contains four No. 10 copper conductors with spade or ring
terminals on the dryer end. The 4th (grounding) conductor must be identified by a green
cover and the neutral conductor by a white cover. The cord should have a suitable strain
relief, and should be a minimum of 4 feet long. The power supply cord and strain relief are
not provided with the dryer.

240 EdwardsStreet,SE
Cleveland.Tennessee37311
Te!:423-472-3333
Fax:423-478-6710

INSTALLATION

INSTALL

DRYER

UNIT AND STAND

The dryer and stand are installed first. With the connections prepared for exhausting, electric
power and gas (if gas stacked washer/dryer,
see Gas Connection),
the dryer and stand are
moved to the location.

NOTE: When moving the dryer and stand on an appliance hand truck, it is recommended
that the dryer and stand be Backed upside down. Protective padding should be used to avoid
damage to the cabinet finish.
Install the vinyl feet on the dryer stand legs. Note the rear legs are "washer" legs and use
the larger feet.
Install electric power cord (electric
tion.

stacked washer/dryer).

See Electrical

Requirements

sec-

The vent connection is lined up from underneath the dryer as the dryer and stand are moved
back into position when a straight-out-the-back
vent is used. When venting down, up, or to
the side, an elbow or flat duct section is placed on to the dryer exhaust before the dryer is
slid into position.
Level the dryer and stand and lock leveling legs using leg lock nuts.

Connect gas line for gas units and check for leaks. Use a liquid soap solution or leak detector. DO NOT use a match or open flame !
With dryer "and stand in position, exhaust vent connected, unit leveled and gas line connected
(if gas unit), power cord set installed (if electric unit), plug power cord into electric outlet.

INSTALL

WASHER

UNIT

Install washer glide bars on rear of washer cabinet. The glide bars are in the installation
package found in the washer tub. Install with rounded edge down. The glide bars will
extend beyond the edge of the cabinet on each side when properly installed.

[]

MA_ raft

Admiral

II

_mII._ENN._il_

_Magic

Chef

240 EdwardsStreet, SE
Cleveland,Tennessee37311
Tel:423-472-,3333
Fax:423-478-67;0

INSTALL

FILL

HOSES

Insert plain hose washers in 90 degree end of fill hoses and screen washers
hoses. The screens should point outward.
The valve inlets are marked

in straight

end of

'_H" and "C" to denote the hot inlet (top) and cold inlet (lower).

Connect 90 degree ends of hoses to the valve. Connect lower hose first. Be sure that hose
connectors are not cross threaded on the valve. Tighten securely by hand plus 1/4 turn with
pliers. Do no overtighten as this can strip the threads on the valve.
Connect

the straight ends of the hose to the corresponding

.MA'ffAG

Adrnirai

_J

supply faucets (hot and cold).

IJENN-AIR

'_'_la{Ji¢

the|

_0st0_er
S_ice

_A4'Y"/,4G

240 EdwardsStreet, SE
Cleveland.Tennessee3731t
Tel: 423-472-3333
Fax:423-478-67;0

INSTALL

DRAIN

HOSE

Secure drain hose to siphon break using the hose clamp provided in the parts package. The
siphon break can be turned right or left to meet the end of the drain hose. Place the gooseneck into the standpipe (or position the gooseneck as if it were in the standpipe). Insert the
clamp over the hose and direct the straight end of the hose toward the siphon break outlet
with a very gradual bend. Push the drain hose over the siphon break outlet and if necessary
twist the hose to relieve any stress on the hose between the siphon break outlet and the
standpipe after the hose is inserted into the standpipe.
NOTE: It is very important when connecting the drain hose that it is properly installed to
minimize the chance of the hose becoming kinked when the washer is moved into position.

If it is necessary to extend the drain hose, attach one end of the extension hose to the siphon
break, and in the other end insert an accessory coupler, similar to the one shown below.
Push the drain hose (hose with short gooseneck) over the coupler until the extension hose and
drain hose join together in approximately the middle of the coupler. When the coupler is
properly used, hose clamps are not required.

€OUFUnl

DUIN

Ma_rAG

Aamtrai

_'|

HOSE

_.JENN-,_Ii:!

_'_lagic

Chef

240EdwardsStreet,SE
Cleveland,Tennessee37311
Te_:423-472-3333
Fax:423-478-6710

If not previously done, remove shipping pads from washer top.
Move the washer into position in front of the dryer and stand. Use caution to avoid floor
damage because of the minimum height of the rear legs.
Tip forward enough for glides to clear the legs of the stand, and guide the glides into the slots
on the top of the stand legs.

Lower Washer Glide
Bar Down into slot.
Slide Washer Back
onto Stand

Before sliding washer back into position,

connect fill hoses.

Be sure the gooseneck is fully inserted into the drain standpipe to prevent any chance of the
hose coming out of the standpipe from the force of the water being discharged.
Connect

the. two control cables, one from the dryer and one from the washer,

.',4A'YI',._,G
Admirat

7|

_JENN-.-,'k_R

as shown.

"_?AlacJi¢

C,._:_f

240 EdwardsStreet,SE
Cleveland.Tennessee3731
Tel: 423-472-3333
Fax:422-478-6710

If the unit is a microprocessor
120 volt AC outlet.

stacked washer/dryer,

connect the washer power cord to the

Slide washer back into position.
A peg on the back right corner of the washer wilt locate in a
socket on the fight leg of the dryer stand.

Adjust the washer front legs down against the floor to raise the washer front slightly. The
washer should be level side to side and just barely higher in the front than in the back (bubble
just touching in the level). Lock leveling leg in position using leg lock nuts.
Remove all instruction
Remove

packages

from washer tub and dryer drum before using units.

tub block ring from washer tub opening.

ADDITIONAL
ODD CYCLE

INFOI/dVIATION

OPERATION

This Maytag stacked washer/dryer is manufactured
for operation on 60 Hz approved electrical service.
It is not designed for use on 50 Hz AC electrical service and conversion of the
product from 60 to 50 cycle operation is not recommended.
For additional information on 50
cycle products, write, MAYTAG INTERNATIONAL,
8700 Bryn Mawr Ave. Chicago, IL
60631. Or call 3t2-7t4-0100
(FAX 312-714-8180).

LUBRICATION
No routine lubrication is required to maintain the stacked washer/dryer.
In the event something does need attention, contact an authorized Maytag dealer or servicer.

_'_!AG

Admira|_l

_,_r_nJENN._a, IR

"_da_jk:

Cb_t

240 EdwardsStreet,SE
C;eve{end,Tennessee37311
Tek 422-472-33,g3
Fax:423-478-67:0

FINISH
All the cabinet and external finishes are protected against rust to keep product looking well
for many years. Cleaning and waxing will provide additional protection to these finishes.

The washer top has a porcelain finish. Since porcelain is "glass" bonded to metal, it is very
durable. Avoid damage from sharp blows of objects or tools used around and in the appliance.
Clean the control panel with a soft damp cloth. Avoid abrasive cleaners that would scratch
the surface. A coat of household was will reduce the chance of scratches on the control panel
surface.
Caution:
If "spilled" or used improperly, bleaches and other strong laundering chemicals can
permanently
spot or stain finishes unless wiped up immediately.
Aerosol pretreat products
can also damage finish on control panel. When using these products on garments placed in
the stacked washer/dryer,
it is advisable to avoid control panel area with the overspray.

WATER

DAMAGE

FROM

FLOODING

In the event the stacked washer/dryer
is exposed to water from flooding, call you local Maytag dealer before using. Always unplug the appliance and have a qualified technician inspect
the appliance before any attempt is made to operate the unit. Never wash product inside and
out with a garden hose or pressure cleaning equipment.

REPLACEMENT

PARTS

If your unit requires replacement parts, contact the dealer from who you purchased your
appliance, or Maytag Customer Service. 240 Edwards St. SE, Cleveland, TN 37311 for
information on the nearest Maytag parts distributor.

Service manuals are available through your dealer or nearest parts distributor.

MAYfAG

._dm_rat

n

_JENN-_MI:;

_lilaqic

C_'lef

A,tt4Y'TAG
240 EdwardsStreet, SE
Cleve]an&Tennessee37311
Tel: 423-472-3333
Fax:423-478-67;8

INSTALLATION

ACCESSOR S

059129

Vent hood - 4" (10.16 cm) opening

059130

Aluminum pipe - 4" x 24:(10.16

059131

Aluminum elbow - 4" (10.16 cm)

059134

Aluminum window plate - 15" x 20" (38.10 cm x 50.80 cm) - 4"
(10.16 cm) hole

059143

Flexible vent kit - contains wide opening vent hood, wall plate, two
clamps and flexible aluminum vent duct

304353

Flexible aluminum vent duct - 4" (10.16 cm) diameter 38" (81.28 cm)
length stretches to 8' (2.44 m)

304630

Clamp for flexible aluminum duct.

306642

Exhaust deflector kit - inside exhaust kit

306205

Natural to LPG conversion it for gas valve

311353

Dacron lint bag

[]

MAYrAG

Admiral

_1

cm x 60.96 cm)

=m_l,ast_l_l.Alla

_._iagi¢

Cb,e_



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 26
Page Layout                     : SinglePage
Page Mode                       : UseNone
Producer                        : Goby Monitor Application version 3, 2, 1, 4
Create Date                     : Thu May 28 07:00:26 2015
Author                          : 
Title                           : 
Subject                         : 
EXIF Metadata provided by EXIF.tools

Navigation menu