Megabyte MEGASCANM1 UHF RFID Reader User Manual rev2

Megabyte Limited UHF RFID Reader rev2

User manual rev2

  megascan M1 User Manual Rev. 1.0  Updated on 28th August, 2009     Technical Contacts and Enquiry: sales@scanmega.com          Website: www.scanmega.com                             (This user manual / product specification is subjected to be changed without prior notice)                          P.1           megascan M1 User Manual Rev. 1.0 Model: megascan M1
  megascan M1 User Manual Rev. 1.0  Updated on 28th August, 2009     Technical Contacts and Enquiry: sales@scanmega.com          Website: www.scanmega.com                             (This user manual / product specification is subjected to be changed without prior notice)                          P.2  Table of Content  FCC statement..................................................................................................... 3 CE statement ....................................................................................................... 3 Chapter 1 Introduction of megascan M1 ........................................................... 4 1.1 Overview of megascan M1 ................................................................ 4 1.2 Ports Description ................................................................................ 5 1.3 Indicators LEDs in megascan M1 ..................................................... 6 1.4 Antenna for megascan M1 ................................................................ 7 1.5 Product Features ................................................................................ 8 1.6 Specification: ....................................................................................... 9 Chapter 2 Installation of megascan M1 ........................................................... 10 2.1 Power up megascan M1 .................................................................. 10 2.2 Environmental Requirements .......................................................... 10 2.3 Start up Procedures ......................................................................... 11 2.4 Caution .............................................................................................. 11 2.5 Professional Installation Instructions .............................................. 12 Chapter 3 Demonstration of RFID Applications ............................................. 15 3.1 Creating RFID Application with megascan M1 .............................. 15 3.1.1   Delivering Application to megascan M1 ................................... 15 3.1.2   Programming Language compatibility ...................................... 15 Chapter 4 Regulatory Information ................................................................... 16 4.1 Federal Communications Commission (FCC) Compliance .......... 16 4.1.1 Radio Frequency Radiation Exposure ....................................... 17 4.2 CE Compliance ................................................................................. 18 Chapter 5 Disclaimer Notice ............................................................................ 19 Chapter 6 Warranty ........................................................................................... 20 Chapter 7 Support ............................................................................................. 21
  megascan M1 User Manual Rev. 1.0  Updated on 28th August, 2009     Technical Contacts and Enquiry: sales@scanmega.com          Website: www.scanmega.com                             (This user manual / product specification is subjected to be changed without prior notice)                          P.3  FCC statement  FCC NOTICE:    To comply with FCC part 15 rules in the United States, the system must be professionally installed to ensure compliance with the Part 15 certification. It is the responsibility of the operator and professional installer to ensure that only certified systems are deployed in the United States.    The use of the system in any other combination (such as co-located antennas transmitting the same information) is expressly forbidden.  CE statement  CE NOTICE:    The  CE  Mark  applies  to  products  regulated  by  certain  European  health,  safety  and environmental protection legislation. The CE Mark is obligatory for products it applies to: the  manufacturer  affixes  the  marking  in  order  to  be  allowed  to  sell  his  product  in  the European market.
  megascan M1 User Manual Rev. 1.0  Updated on 28th August, 2009     Technical Contacts and Enquiry: sales@scanmega.com          Website: www.scanmega.com                             (This user manual / product specification is subjected to be changed without prior notice)                          P.4 Chapter 1 Introduction of megascan M1  1.1 Overview of megascan M1   The Megabyte Ltd., megascan M1 RFID reader does more than simply read and acts as a data conduit, they need processing speed and ample memory. is an UHF RFID reader, which  includes  powerful  RFID  reader  with  17  RFID  antenna  ports,  which  operates  in 860MHz to 930MHz UHF band and is compliance with ISO 18000-6C Tag Air Interfaces with read and write function. megascan M1 reduces implementation cost and deployment time;  improves  reliability  in  harsh  environments  and  enhances  overall  RFID  system performance.  •  The  megascan  M1  Intelligent  RFID  Reader  supports  protocols,  UHF  CLASS  1 GEN2 EPC C1G2/ISO 18000-6C, (865-868 MHz RFID frequency band) in Europe as well as (902-928 MHz RFID frequency band) in United States.
  megascan M1 User Manual Rev. 1.0  Updated on 28th August, 2009     Technical Contacts and Enquiry: sales@scanmega.com          Website: www.scanmega.com                             (This user manual / product specification is subjected to be changed without prior notice)                          P.5 1.2  Ports Description      The megascan M1 has several types of input/output port:  Items  Name  Description 1  Ethernet Port, RJ-45  10BaseTx/100BaseTx port that connects the reader to your Ethernet  network,  which  is  embedded  with  Power  over Ethernet (PoE) Technology. 2  UHF RFID Antenna Port(s)      17 SMA ports for external UHF antenna connection; -16 ports with LED signal light, - 1 dedicate RF output ports for M2 connection,
  megascan M1 User Manual Rev. 1.0  Updated on 28th August, 2009     Technical Contacts and Enquiry: sales@scanmega.com          Website: www.scanmega.com                             (This user manual / product specification is subjected to be changed without prior notice)                          P.6  1.3  Indicators LEDs in megascan M1      The megascan M1 has different LEDs to indicate the reader status.  Name  Label  Description LAN Status, 10BaseTx  10M  Turn ON when 10Mbps network detected LAN Status, 10BaseTx  100M  Turn ON when 100Mbps network detected Ready, Read and write  READY  Turn ON when M1 is POWER ON, Flashes when M1 is reading. Antenna Ports 1-16  1,2 …16  Turn  on  when  the  antenna  is  ready  to perform schedule task
  megascan M1 User Manual Rev. 1.0  Updated on 28th August, 2009     Technical Contacts and Enquiry: sales@scanmega.com          Website: www.scanmega.com                             (This user manual / product specification is subjected to be changed without prior notice)                          P.7 1.4 Antenna for megascan M1     There is no antenna shipped with megascan M1. The following antenna model is used for megascan M1:  MRD E42
  megascan M1 User Manual Rev. 1.0  Updated on 28th August, 2009     Technical Contacts and Enquiry: sales@scanmega.com          Website: www.scanmega.com                             (This user manual / product specification is subjected to be changed without prior notice)                          P.8  1.5 Product Features  •  Excellent RFID monostatic RF performance with 17 external SMA antenna ports,  •  1 Watt (30dBm) Tx output levels and -80dBm Rx read sensitivity,  •  Consistently supports read ranges up to 30 feet,  •  Dense Reader Mode (DRM) Capability,  •  Power over Ethernet (PoE) connectivity,  •  Low power consumption,  •  Adjustable output Tx power levels over +5 to 30dBm range in 1dB steps,  •  RJ-45, 10/100Mbps Ethernet interface, TCP/IP,  •  Small Form, Fit size: 257mm(L) x 182mm(W) x 25mm(H),  •  Standalone and Server mode middleware control support,  •  High durability in harsh environments,    •  Easy installation and maintenance,  •  All-in-one compact design,  •  Fanless Design for protection of dirt, dust, insects, liquids,    •  Supporting tag interface of EPC C1G2/ISO 18000-6C(UHF C1G2),
  megascan M1 User Manual Rev. 1.0  Updated on 28th August, 2009     Technical Contacts and Enquiry: sales@scanmega.com          Website: www.scanmega.com                             (This user manual / product specification is subjected to be changed without prior notice)                          P.9  1.6 Specification:   Features   Compliant with EPC global C1G2/ISO 18000-6C,   Dense Reader Mode Capability,   Adjustable Output Power (up to +30dBm Max),   Exceptional Performance and Reliability,   Low Power Consumption,   Read Distance up to 30 feet(9m), Air-interface Protocols    EPC Gen 2 / ISO 18000-6C, Frequency Band   FCC 902-928 MHz,   ETSI 865-868 MHz,   NCC 922-928 MHz,   SRRC 920-925 MHz, RF Output Power    Adjustable from +5 to + 30dBm in 1 dB steps, Supply Voltage    Power over Ethernet (PoE), IEEE standard. 802.3af compliant, Power Consumption    Idle mode: 0.2W,   Scan mode: 8.95W@30dBm, Communication Interface    RJ-45, 10/100Mbps Ethernet Interface, TCP/IP, Regulatory   FCC 47 CFR Ch.1 Part 15,   ETSI EN 302-208,   NCC LP002,   RoHS, Tags Supported    Alien, Avery Dennison, Hitachi, Impinj, NXP, Omron, Rafsec, TI, Physical Size    257mm (L) x 182 mm (W) x 25 mm (H), External Antenna    17 ports SMA connector support external Monostatic Antenna up to 6dBi   VSWR < 1.5:1 @ 50ohm, Effective Range    Over 30 feet (9 meters) with 6dBi External Antenna , Environment    Storage Temperature: -40°C to 85°C,   Operating Temperature: 0°C to 40°C,
  megascan M1 User Manual Rev. 1.0  Updated on 28th August, 2009     Technical Contacts and Enquiry: sales@scanmega.com          Website: www.scanmega.com                             (This user manual / product specification is subjected to be changed without prior notice)                          P.10 Chapter 2 Installation of megascan M1 2.1 Power up megascan M1  This section explains how to set-up megascan M1 and connect the megascan M1 to your network and antenna: - Choose  the  PoE  feature  router/switch  and  compliance  with  IEEE  std. 802.3af-2003, and connect with Cat.5 and higher infrastructure cable,  - Antenna  port  is  standard  SMA  Jack(female),  the  RF  cable/antenna  connector should be standard SMA Plug(male),  - megascan M1 operates at UHF frequency band, ranging from 865MHz to 928MHz (ETSI 865-868 MHz, FCC 902-928 MHz, SRRC 920-925 MHz and NCC 922-928 MHz); the setting depends on countries’ regulations.  - Choose the right frequency band UHF antenna for your application.   2.2 Environmental Requirements  The  next  table  includes  environmental  requirements  for  the  megascan  M1.  Choose  a location that meets these requirements.    Description          Minimum      Maximum  Operating temperature        0ºC       55ºC    Storage temperature         -40ºC        85ºC    Humidity (non-condensing)      10%        90%
  megascan M1 User Manual Rev. 1.0  Updated on 28th August, 2009     Technical Contacts and Enquiry: sales@scanmega.com          Website: www.scanmega.com                             (This user manual / product specification is subjected to be changed without prior notice)                          P.11 2.3 Start up Procedures    1.  Before installation of megascan M1, please follow the steps below:  2.  Install and fasten the megascan M1 in right location.    3.  Before  turn  ON  the  megascan  M1  by  connecting  ethernet  cable  to  PoE Router/switch.    4.  The default IP / subnet mask is as follows: 192.168.1.254 / 255.255.255.0, change the IP setting for your network.  5.  Please make sure the antenna port is connected an UHF antenna before turn on the RF power for testing.    Caution: Each port must have either an antenna or a terminator connected. Do not apply power to the megascan M1 unless an antenna or terminator is installed on each antenna port.  2.4 Caution  Danger of Electric Shock  •  Disconnect  the  device  from  the  electric  supply  before  cleaning  or  performing maintenance on the machine. •  Keep this device dry. •  For in-door use only.    Not designed for out-door purpose. •  Turn off or unplug the machine when it is not in use.    Please  read  the  information  contained  within  this  user  manual  prior  to  attempting installation  and  operation  of  the  RFID  Reader.  Failure  to  install  and  operate  the  RFID Terminal (megascan M1) in accordance with the information contained in this manual may result in unsatisfactory performance.
  megascan M1 User Manual Rev. 1.0  Updated on 28th August, 2009     Technical Contacts and Enquiry: sales@scanmega.com          Website: www.scanmega.com                             (This user manual / product specification is subjected to be changed without prior notice)                          P.12  2.5 Professional Installation Instructions Safety and Regulatory Compliance Information This  document contains  important safety and  regulatory compliance  information  for  the following products:  Please read this document before installing and using your product and see the following sections for more information: • Safety Information   • Federal Communications Commission (FCC) Compliance – Modifications – Warnings • Information for Professional Installers • Regulatory Compliance Certifications Summary  Safety Information All  products  are  intended  to  be  installed,  used,  and  maintained  by  experienced telecommunications personnel only. When using this device, basic safety precautions should always be followed to reduce the risk of fire, electrical shock, and injury to persons, including the following: •  Operate  and  install  these  products  as  described  in  this  manual.  Equipment  must  be installed and used in strict accordance with the manufacturer's instructions as described in the user documentation provided. •  Installation  of  these  products  in  the  end  use  must  conform  to  local  regulations  and codes. • Products are to be used with and powered by only the power injector provided. • A 13-amp circuit breaker is required at the power source. • Do not connect or disconnect the power cable to the equipment when the power injector is plugged into an AC power outlet. •  Servicing  of  these  products  should  be  performed  only by  trained  personnel.    Do  not disassemble. By opening or removing any covers, you may expose yourself to hazardous energy  parts.  Incorrect  reassembly  of  these  products  can  cause  a  malfunction  and/or electric shock when the units are subsequently used. No user serviceable parts; all repairs and service must be handled by a qualified service center. • Do not insert any objects of any shape or size inside these products while powered on. Object may contact hazardous energy parts that could result in a risk of fire or personal injury. • Do not remove or alter the Marking label provided on these products. • To avoid the risk of electric shock from lightning, do not use these products during an electrical storm. • When using these products with an external antenna, see the installation documentation provided with the antenna system.
  megascan M1 User Manual Rev. 1.0  Updated on 28th August, 2009     Technical Contacts and Enquiry: sales@scanmega.com          Website: www.scanmega.com                             (This user manual / product specification is subjected to be changed without prior notice)                          P.13  Federal Communications Commission (FCC) Compliance These  products  operate  at  the  following  frequencies  in  compliance  with  Part  15  of  the FCC rules: -  RFID; 902 MHz - 928 MHz,  Operation is subject to the following two conditions: 1) this device may not cause harmful interference,  and  2)  this  device  must  accept  any  interference  received,  including interference that may cause undesired operation. To comply with  the  FCC radio frequency  exposure requirements,  the following  antenna installation and device operating configurations must be satisfied: • Product models using external antennas require professional installation. The antennas used  for  professional  installation  must  be  fixed-mounted  on  indoor/outdoor  permanent structures with a separation distance from all persons of at least 25 cm (approximately 10 inches). • Antennas must not  be co-located and must not operate in conjunction with  any other antenna or transmitter. • Shielded cables must be used with this unit to ensure compliance with the Class B FCC limits.  Warnings Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.      The equipment has been tested and found to comply with part 15 of the FCC rules.  These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy  and,  if  not  installed  and  used  in  accordance  with  the  instructions,  may  cause harmful  interference  to  radio  communications.    However,  there  is  no  guarantee  that interference will not occur in a particular installation. If this equipment does cause harmful interference  to  radio  or  television  reception,  which  can  be  determined  by  turning  the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures:  • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. •  Connect  the  equipment  into  an  outlet  or  on  a  circuit  different  from  that  to  which  the receiver is connected. • Consult the dealer or an experienced radio / technician for help.  To  ensure  safety  of  users,  the  FCC  has  established  criteria  for  the  amount  of  radio frequency energy that  can be safely absorbed by a user or bystander according to  the intended usage of the product. This product has been tested and found to comply with the
  megascan M1 User Manual Rev. 1.0  Updated on 28th August, 2009     Technical Contacts and Enquiry: sales@scanmega.com          Website: www.scanmega.com                             (This user manual / product specification is subjected to be changed without prior notice)                          P.14 FCC criteria. The megascan M1  shall be installed & used such that  parts of  the user’s body ther than the hands should be maintained at a comfortable distance of approximately 25 cm or more.  In some situations or environments, the use of wireless devices may be restricted by the proprietor  of  the  building  or  responsible  representatives  of  the  organization.  These situations may, for example, include the use of wireless equipment on board airplanes, or in  any  other  environment  where  the  risk  of  interference  to  other  devices  or  services  is perceived or identified as harmful. If you are uncertain of the policy that applies on the use of wireless equipment in a specific organization  or  environment  (such  as  airports),  you  are  encouraged  to  ask  for authorization to use this device prior to turning on the equipment.  Modifications The FCC requires the user to be notified that any changes or modifications to this device that  are  not  expressly  approved  by  the  manufacturer  may  void  the  user’s  authority  to operate  the  equipment.  The  correction  of  interference  caused  by  unauthorized modification,  substitution  or  attachment  will  be  the  responsibility  of  the  user.  The manufacturer and its authorized resellers or distributors are not liable for any damage or violation  of  government  regulations  that  may  arise  from  failing  to  comply  with  these guidelines.  Information for Professional Installers All products must be professionally installed, and the transmit power of the system must be adjusted by the professional installers to ensure that the system EIRP is in compliance with the limit specified by the regulatory authority of the country of application. See the following sections for more information:  Professional installers should select only the antenna types listed in the following table, Frequency Band     Antenna Type   RFID; 900 MHz          Panel Antenna The megascan M1 is only used with panel antenna. (model: MRD E42)
  megascan M1 User Manual Rev. 1.0  Updated on 28th August, 2009     Technical Contacts and Enquiry: sales@scanmega.com          Website: www.scanmega.com                             (This user manual / product specification is subjected to be changed without prior notice)                          P.15 Chapter 3 Demonstration of RFID Applications  3.1 Creating RFID Application with megascan M1  Megabyte  Ltd.  megascan  M1  is  an  intelligent  reader  and  compliance  with  EPC  global C1G2/ISO 18000-6C, Users can develop own UHF RFID application on this platform.    3.1.1   Delivering Application to megascan M1  When the user wants to deliver applications to the megascan M1, they just simply install the program in Windows XP and Linux platform.  3.1.2   Programming Language compatibility  Users  may  use  several  types  of  programming  language,  for  examples, C++, C#.NET, Java and Java script.
  megascan M1 User Manual Rev. 1.0  Updated on 28th August, 2009     Technical Contacts and Enquiry: sales@scanmega.com          Website: www.scanmega.com                             (This user manual / product specification is subjected to be changed without prior notice)                          P.16  Chapter 4 Regulatory Information 4.1  Federal Communications Commission (FCC) Compliance  This equipment has been tested and found to comply with the limits for a class B digital device,  pursuant  to  Part  15  of  the  FCC  Rules.  These  limits  are  designed  to  provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates uses and can radiate radio frequency energy  and,  if  not  installed  and  used  in  accordance  with  the  instructions,  may  cause harmful  interference  to  radio  communications.  However,  there  is  no  guarantee  that interference will not occur in a particular installation. If this equipment does cause harmful interference  to  radio  or  television  reception,  which  can  be  determined  by  turning  the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  •  Reorient or relocate the receiving antenna  •  Increase the separation between the equipment and receiver  •  Consult the dealer or an qualified radio/TV technician for assistance  FCC NOTICE: To comply with FCC part 15 rules in the United States, the system must be professionally  installed  to  ensure  compliance  with  the  Part  15  certification.  It  is  the responsibility  of  the  operator  and  professional  installer  to  ensure  that  only  certified systems  are  deployed  in  the  United  States.  The  use  of  the  system  in  any  other combination (such as co-located antennas transmitting the same information) is expressly forbidden.  WARNING:  DO  NOT  ATTEMPT  TO  SERVICE  THE  WIRELESS  COMMUNICATION  DEVICE YOURSELF.  SUCH  ACTION  MAY  VOID  THE  WARRANTY.  THE  MEGASCAN  M1  IS  FACTORY TUNED.  NO CUSTOMER CALIBRATION OR TUNING IS REQUIRED. CONTACT  MEGABYTE LTD. TECHNICAL  SUPPORT  FOR  INFORMATION  ABOUT  SERVICING  YOUR  WIRELESS COMMUNICATION DEVICE.  Note: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
  megascan M1 User Manual Rev. 1.0  Updated on 28th August, 2009     Technical Contacts and Enquiry: sales@scanmega.com          Website: www.scanmega.com                             (This user manual / product specification is subjected to be changed without prior notice)                          P.17 4.1.1  Radio Frequency Radiation Exposure  The highest RF output power of the unit was measured at 29.60dBm at 902.75 MHz.  According  to  §1.1310  of  the  FCC  rules,  the  power  density  limit  for General  Population/Uncontrolled  Exposure  at  902.75  MHz  is  f(MHz)/1500  = 0.602mW/cm2. The MPE  is  calculated  to  show  the  required  separation  distance  that  must  be maintained during installation  to  maintain compliance  with  the  power density limit. The minimum required cable length is 1.5m to be used with this device.    The following formula was used to calculate the Power Density:  S= Where: S = Power Density P = Power input to the external antenna (Output power from the EUT antenna Port(dBm) – cable loss(dB)) G = Gain of Transmit Antenna (Linear gain) R = Distance from Transmitting Antenna The power density at 25cm separation is: S=  For this device, the calculation is as follows: P  =  29.60dBm  (Output power  from  the  EUT antenna  Port)  –  0.75dB  (Cable Loss*)              = 28.85dBm (767.361mW)              *Cable Loss = (0.75dB) : 1.5m long of 0.5dB/m loss G = Worst Case Antenna Gain = 6dB = anti-log(6.0/10) = 3.98 At 25cm separation, S = ((767.361) x (3.98)) / (4π(25)2) = 0.389mW/cm2   Based on the above calculation for 25cm separation, the power density does not exceed FCC limit of 0.602mW/cm2.
  megascan M1 User Manual Rev. 1.0  Updated on 28th August, 2009     Technical Contacts and Enquiry: sales@scanmega.com          Website: www.scanmega.com                             (This user manual / product specification is subjected to be changed without prior notice)                          P.18 4.2  CE Compliance  This  device  has  been  tested  to  and  conforms  to  the  regulatory  requirements  of  the European  Union  and  has  attained  CE  Marking.  The  CE  Mark  is  a  conformity  marking consisting  of  the  letters  "CE".  The  CE  Mark  applies  to  products  regulated  by  certain European  health,  safety  and  environmental  protection  legislation.  The  CE  Mark  is obligatory for products it applies to: the manufacturer affixes the marking in order to be allowed to sell his product in the European market.    The CE Marking is not a quality-mark. Foremost, it refers to the safety rather than to the quality  of  a  product.  Secondly,  CE  Marking  is  mandatory  for  the  product  it  applies  to, whereas most quality markings are voluntary.
  megascan M1 User Manual Rev. 1.0  Updated on 28th August, 2009     Technical Contacts and Enquiry: sales@scanmega.com          Website: www.scanmega.com                             (This user manual / product specification is subjected to be changed without prior notice)                          P.19  Chapter 5 Disclaimer Notice  Disclaimer Notice  The  manufacturer  shall  not  be  liable  for  errors  contained  herein  or  for  incidental  or consequential  damages  in  connection  with  the  furnishing,  performance  or  use  of  this material.  This  document  contains  proprietary  information,  which  is  protected  by international  patent  applications  and  copyright.  All  rights  reserved.  No  part  of  this document may  be copied, reproduced or  translated without prior written consent  of the manufacturer. The manufacturer reserves the right to revise this publication and to make changes from time to time in the contents hereof without obligation to notify any person of such  revisions  or  changes.  The  manufacturer  also  reserves  the  right  to  change  the specifications without notice.
  megascan M1 User Manual Rev. 1.0  Updated on 28th August, 2009     Technical Contacts and Enquiry: sales@scanmega.com          Website: www.scanmega.com                             (This user manual / product specification is subjected to be changed without prior notice)                          P.20  Chapter 6 Warranty  1. Megabyte Ltd warrants to the User that the Products sold to the User will comply with their published specifications and will be of satisfactory quality and that Megabyte Ltd is entitled to  sell  the  Products  to  the  User.  Megabyte  Ltd  warrants  that  for  a  period  of  twelve  (12) months from date of purchase (“the Warranty Period”), the products will be free from defects in materials and workmanship.  2. During  the  Warranty  Period,  Megabyte  Ltd  will  repair,  or  if  in  Megabyte  Ltd’s  opinion necessary  replace,  the  defective  product  returned  to  Megabyte  Ltd’s  head  office  in  Hong Kong. The defective production must be returned in its original packaging and all shipping and handling charges shall be borne by the Users.  3. The Warranty Period shall not be extended by reason of any repair or replacement.  4. Megabyte Ltd shall have no liability to the User for any damage to or defects in any of the Products caused by fair wear and tear, improper use, negligent handling, failure to observe this  User  Manual  and  the  instructions  accompanying  the  Products  or  any  alterations maintenance  or  repair  to  the  Products  by  any  person  other  than  Megabyte  Ltd,  use  of non-Megabyte  Ltd  parts,  accessories  or  equipment,  or  third  party  software  which  would damage the Products.  5. Unless  in  the  case  of  any  damage  to  or  defect  in  the  Products  which  would  have  been apparent  on  reasonable  visual  inspection,  the  User  notifies  Megabyte  Ltd  of  the  same  in writing within 7 days after the date of purchase thereof, or in the case of any damage to or defects in the Products which would not have been apparent on reasonable visual inspection the  User  notifies  Megabyte  Ltd  of  the  same  in  writing  7  days  after  the  defect  becomes apparent to the User, the User shall not be entitled to reject the Products concerned.  6. The  User  shall be  responsible for  properly  storing  and  making back  up  copies  of  all data which may be stored in the Products. Megabyte Ltd shall not be responsible for any lost of data as a result of any repair or replacement.    7. Except  as  expressly  provided  in  this User  Manual  no  warranty,  condition,  undertaking, or term,  express or  implied,  statutory or otherwise,  as  to  the  condition, quality, performance, durability or fitness for purpose of the Products is given or assumed by Megabyte Ltd and all such warranties, conditions, undertakings and terms are hereby excluded to the fullest extent permitted by law.
  megascan M1 User Manual Rev. 1.0  Updated on 28th August, 2009     Technical Contacts and Enquiry: sales@scanmega.com          Website: www.scanmega.com                             (This user manual / product specification is subjected to be changed without prior notice)                          P.21  Chapter 7 Support  Technical support/sales enquiry can be obtained from Megabyte Ltd.  Please email to: sales@scanmega.com