Megabyte MEGASCANM1 UHF RFID Reader User Manual rev2

Megabyte Limited UHF RFID Reader rev2

User manual rev2

Download: Megabyte MEGASCANM1 UHF RFID Reader User Manual rev2
Mirror Download [FCC.gov]Megabyte MEGASCANM1 UHF RFID Reader User Manual rev2
Document ID1161384
Application ID42hZx0DGvIaCiIHeUuYymg==
Document DescriptionUser manual rev2
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize31.72kB (396474 bits)
Date Submitted2009-08-31 00:00:00
Date Available2009-08-31 00:00:00
Creation Date2009-08-28 14:22:12
Producing SoftwareGPL Ghostscript 8.15
Document Lastmod2009-08-28 16:40:37
Document TitleMicrosoft Word - megascan M1 User Manual Rev1.1f.doc
Document CreatorPScript5.dll Version 5.2.2
Document Author: Jack Chan

megascan M1 User Manual Rev. 1.0
Updated on 28th August, 2009
megascan M1 User Manual
Rev. 1.0
Model: megascan M1
Technical Contacts and Enquiry: sales@scanmega.com
Website: www.scanmega.com
(This user manual / product specification is subjected to be changed without prior notice)
P.1
megascan M1 User Manual Rev. 1.0
Updated on 28th August, 2009
Table of Content
FCC statement..................................................................................................... 3
CE statement ....................................................................................................... 3
Chapter 1 Introduction of megascan M1 ........................................................... 4
1.1
Overview of megascan M1 ................................................................ 4
1.2
Ports Description ................................................................................ 5
1.3
Indicators LEDs in megascan M1 ..................................................... 6
1.4
Antenna for megascan M1 ................................................................ 7
1.5
Product Features ................................................................................ 8
1.6
Specification: ....................................................................................... 9
Chapter 2 Installation of megascan M1 ........................................................... 10
2.1
Power up megascan M1 .................................................................. 10
2.2
Environmental Requirements .......................................................... 10
2.3
Start up Procedures ......................................................................... 11
2.4
Caution .............................................................................................. 11
2.5
Professional Installation Instructions .............................................. 12
Chapter 3 Demonstration of RFID Applications ............................................. 15
3.1
Creating RFID Application with megascan M1 .............................. 15
3.1.1
Delivering Application to megascan M1................................... 15
3.1.2
Programming Language compatibility...................................... 15
Chapter 4 Regulatory Information ................................................................... 16
4.1
Federal Communications Commission (FCC) Compliance .......... 16
4.1.1 Radio Frequency Radiation Exposure ....................................... 17
4.2
CE Compliance ................................................................................. 18
Chapter 5 Disclaimer Notice ............................................................................ 19
Chapter 6 Warranty ........................................................................................... 20
Chapter 7 Support............................................................................................. 21
Technical Contacts and Enquiry: sales@scanmega.com
Website: www.scanmega.com
(This user manual / product specification is subjected to be changed without prior notice)
P.2
megascan M1 User Manual Rev. 1.0
Updated on 28th August, 2009
FCC statement
FCC NOTICE:
To comply with FCC part 15 rules in the United States, the system must be professionally
installed to ensure compliance with the Part 15 certification. It is the responsibility of the
operator and professional installer to ensure that only certified systems are deployed in
the United States.
The use of the system in any other combination (such as co-located antennas transmitting
the same information) is expressly forbidden.
CE statement
CE NOTICE:
The CE Mark applies to products regulated by certain European health, safety and
environmental protection legislation. The CE Mark is obligatory for products it applies to:
the manufacturer affixes the marking in order to be allowed to sell his product in the
European market.
Technical Contacts and Enquiry: sales@scanmega.com
Website: www.scanmega.com
(This user manual / product specification is subjected to be changed without prior notice)
P.3
megascan M1 User Manual Rev. 1.0
Updated on 28th August, 2009
Chapter 1 Introduction of megascan M1
1.1 Overview of megascan M1
The Megabyte Ltd., megascan M1 RFID reader does more than simply read and acts as a
data conduit, they need processing speed and ample memory. is an UHF RFID reader,
which includes powerful RFID reader with 17 RFID antenna ports, which operates in
860MHz to 930MHz UHF band and is compliance with ISO 18000-6C Tag Air Interfaces
with read and write function. megascan M1 reduces implementation cost and deployment
time; improves reliability in harsh environments and enhances overall RFID system
performance.
•
The megascan M1 Intelligent RFID Reader supports protocols, UHF CLASS 1
GEN2 EPC C1G2/ISO 18000-6C, (865-868 MHz RFID frequency band) in Europe
as well as (902-928 MHz RFID frequency band) in United States.
Technical Contacts and Enquiry: sales@scanmega.com
Website: www.scanmega.com
(This user manual / product specification is subjected to be changed without prior notice)
P.4
megascan M1 User Manual Rev. 1.0
Updated on 28th August, 2009
1.2 Ports Description
The megascan M1 has several types of input/output port:
Items
Name
Description
Ethernet Port, RJ-45
10BaseTx/100BaseTx port that connects the reader to your
Ethernet network, which is embedded with Power over
Ethernet (PoE) Technology.
UHF RFID Antenna Port(s)
17 SMA ports for external UHF antenna connection;
-16 ports with LED signal light,
- 1 dedicate RF output ports for M2 connection,
Technical Contacts and Enquiry: sales@scanmega.com
Website: www.scanmega.com
(This user manual / product specification is subjected to be changed without prior notice)
P.5
megascan M1 User Manual Rev. 1.0
Updated on 28th August, 2009
1.3 Indicators LEDs in megascan M1
The megascan M1 has different LEDs to indicate the reader status.
Name
Label
Description
LAN Status, 10BaseTx
10M
Turn ON when 10Mbps network detected
LAN Status, 10BaseTx
100M
Turn ON when 100Mbps network detected
Ready, Read and write
READY
Turn ON when M1 is POWER ON,
Flashes when M1 is reading.
Antenna Ports 1-16
1,2 …16
Turn on when the antenna is ready to
perform schedule task
Technical Contacts and Enquiry: sales@scanmega.com
Website: www.scanmega.com
(This user manual / product specification is subjected to be changed without prior notice)
P.6
megascan M1 User Manual Rev. 1.0
Updated on 28th August, 2009
1.4 Antenna for megascan M1
There is no antenna shipped with megascan M1. The following antenna model is used for
megascan M1:
MRD E42
Technical Contacts and Enquiry: sales@scanmega.com
Website: www.scanmega.com
(This user manual / product specification is subjected to be changed without prior notice)
P.7
megascan M1 User Manual Rev. 1.0
Updated on 28th August, 2009
1.5 Product Features
•
Excellent RFID monostatic RF performance with 17 external SMA antenna ports,
•
1 Watt (30dBm) Tx output levels and -80dBm Rx read sensitivity,
•
Consistently supports read ranges up to 30 feet,
•
Dense Reader Mode (DRM) Capability,
•
Power over Ethernet (PoE) connectivity,
•
Low power consumption,
•
Adjustable output Tx power levels over +5 to 30dBm range in 1dB steps,
•
RJ-45, 10/100Mbps Ethernet interface, TCP/IP,
•
Small Form, Fit size: 257mm(L) x 182mm(W) x 25mm(H),
•
Standalone and Server mode middleware control support,
•
High durability in harsh environments,
•
Easy installation and maintenance,
•
All-in-one compact design,
•
Fanless Design for protection of dirt, dust, insects, liquids,
•
Supporting tag interface of EPC C1G2/ISO 18000-6C(UHF C1G2),
Technical Contacts and Enquiry: sales@scanmega.com
Website: www.scanmega.com
(This user manual / product specification is subjected to be changed without prior notice)
P.8
megascan M1 User Manual Rev. 1.0
Updated on 28th August, 2009
1.6 Specification:
Compliant with EPC global C1G2/ISO 18000-6C,
Dense Reader Mode Capability,
Features
Adjustable Output Power (up to +30dBm Max),
Exceptional Performance and Reliability,
Low Power Consumption,
Read Distance up to 30 feet(9m),
Air-interface Protocols
EPC Gen 2 / ISO 18000-6C,
FCC 902-928 MHz,
Frequency Band
ETSI 865-868 MHz,
NCC 922-928 MHz,
SRRC 920-925 MHz,
RF Output Power
Supply Voltage
Power Consumption
Adjustable from +5 to + 30dBm in 1 dB steps,
Power over Ethernet (PoE), IEEE standard. 802.3af compliant,
Idle mode: 0.2W,
Scan mode: 8.95W@30dBm,
Communication Interface
RJ-45, 10/100Mbps Ethernet Interface, TCP/IP,
FCC 47 CFR Ch.1 Part 15,
Regulatory
ETSI EN 302-208,
NCC LP002,
RoHS,
Tags Supported
Physical Size
External Antenna
Effective Range
Environment
Alien, Avery Dennison, Hitachi, Impinj, NXP, Omron, Rafsec, TI,
257mm (L) x 182 mm (W) x 25 mm (H),
17 ports SMA connector support external Monostatic Antenna up to 6dBi
VSWR < 1.5:1 @ 50ohm,
Over 30 feet (9 meters) with 6dBi External Antenna ,
Storage Temperature: -40°C to 85°C,
Operating Temperature: 0°C to 40°C,
Technical Contacts and Enquiry: sales@scanmega.com
Website: www.scanmega.com
(This user manual / product specification is subjected to be changed without prior notice)
P.9
megascan M1 User Manual Rev. 1.0
Updated on 28th August, 2009
Chapter 2 Installation of megascan M1
2.1 Power up megascan M1
This section explains how to set-up megascan M1 and connect the megascan M1 to your
network and antenna:
- Choose the PoE feature router/switch and compliance with IEEE std.
802.3af-2003, and connect with Cat.5 and higher infrastructure cable,
Antenna port is standard SMA Jack(female), the RF cable/antenna connector
should be standard SMA Plug(male),
megascan M1 operates at UHF frequency band, ranging from 865MHz to 928MHz
(ETSI 865-868 MHz, FCC 902-928 MHz, SRRC 920-925 MHz and NCC 922-928
MHz); the setting depends on countries’ regulations.
Choose the right frequency band UHF antenna for your application.
2.2 Environmental Requirements
The next table includes environmental requirements for the megascan M1. Choose a
location that meets these requirements.
Description
Minimum
Maximum
Operating temperature
0ºC
55ºC
Storage temperature
-40ºC
85ºC
Humidity (non-condensing)
10%
90%
Technical Contacts and Enquiry: sales@scanmega.com
Website: www.scanmega.com
(This user manual / product specification is subjected to be changed without prior notice)
P.10
megascan M1 User Manual Rev. 1.0
Updated on 28th August, 2009
2.3 Start up Procedures
1. Before installation of megascan M1, please follow the steps below:
2. Install and fasten the megascan M1 in right location.
3. Before turn ON the megascan M1 by connecting ethernet cable to PoE
Router/switch.
4. The default IP / subnet mask is as follows: 192.168.1.254 / 255.255.255.0, change
the IP setting for your network.
5. Please make sure the antenna port is connected an UHF antenna before turn on
the RF power for testing.
Caution: Each port must have either an antenna or a terminator connected.
Do not apply power to the megascan M1 unless an antenna or terminator is
installed on each antenna port.
2.4 Caution
Danger of Electric Shock
•
Disconnect the device from the electric supply before cleaning or performing
maintenance on the machine.
•
•
•
Keep this device dry.
For in-door use only. Not designed for out-door purpose.
Turn off or unplug the machine when it is not in use.
Please read the information contained within this user manual prior to attempting
installation and operation of the RFID Reader. Failure to install and operate the RFID
Terminal (megascan M1) in accordance with the information contained in this manual may
result in unsatisfactory performance.
Technical Contacts and Enquiry: sales@scanmega.com
Website: www.scanmega.com
(This user manual / product specification is subjected to be changed without prior notice)
P.11
megascan M1 User Manual Rev. 1.0
Updated on 28th August, 2009
2.5 Professional Installation Instructions
Safety and Regulatory Compliance Information
This document contains important safety and regulatory compliance information for the
following products:
Please read this document before installing and using your product and see the following
sections for more information:
• Safety Information
• Federal Communications Commission (FCC) Compliance
– Modifications
– Warnings
• Information for Professional Installers
• Regulatory Compliance Certifications Summary
Safety Information
All products are intended to be installed, used, and maintained by experienced
telecommunications personnel only.
When using this device, basic safety precautions should always be followed to reduce the
risk of fire, electrical shock, and injury to persons, including the following:
• Operate and install these products as described in this manual. Equipment must be
installed and used in strict accordance with the manufacturer's instructions as described in
the user documentation provided.
• Installation of these products in the end use must conform to local regulations and
codes.
• Products are to be used with and powered by only the power injector provided.
• A 13-amp circuit breaker is required at the power source.
• Do not connect or disconnect the power cable to the equipment when the power injector
is plugged into an AC power outlet.
• Servicing of these products should be performed only by trained personnel. Do not
disassemble. By opening or removing any covers, you may expose yourself to hazardous
energy parts. Incorrect reassembly of these products can cause a malfunction and/or
electric shock when the units are subsequently used. No user serviceable parts; all repairs
and service must be handled by a qualified service center.
• Do not insert any objects of any shape or size inside these products while powered on.
Object may contact hazardous energy parts that could result in a risk of fire or personal
injury.
• Do not remove or alter the Marking label provided on these products.
• To avoid the risk of electric shock from lightning, do not use these products during an
electrical storm.
• When using these products with an external antenna, see the installation documentation
provided with the antenna system.
Technical Contacts and Enquiry: sales@scanmega.com
Website: www.scanmega.com
(This user manual / product specification is subjected to be changed without prior notice)
P.12
megascan M1 User Manual Rev. 1.0
Updated on 28th August, 2009
Federal Communications Commission (FCC) Compliance
These products operate at the following frequencies in compliance with Part 15 of the
FCC rules:
- RFID; 902 MHz - 928 MHz,
Operation is subject to the following two conditions: 1) this device may not cause harmful
interference, and 2) this device must accept any interference received, including
interference that may cause undesired operation.
To comply with the FCC radio frequency exposure requirements, the following antenna
installation and device operating configurations must be satisfied:
• Product models using external antennas require professional installation. The antennas
used for professional installation must be fixed-mounted on indoor/outdoor permanent
structures with a separation distance from all persons of at least 25 cm (approximately 10
inches).
• Antennas must not be co-located and must not operate in conjunction with any other
antenna or transmitter.
• Shielded cables must be used with this unit to ensure compliance with the Class B FCC
limits.
Warnings
Changes or modifications to this unit not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
The equipment has been tested and found to comply with part 15 of the FCC rules.
These limits are designed to provide reasonable protection against harmful interference in
a residential installation. This equipment generates uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try and correct the interference by one or
more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet or on a circuit different from that to which the
receiver is connected.
• Consult the dealer or an experienced radio / technician for help.
To ensure safety of users, the FCC has established criteria for the amount of radio
frequency energy that can be safely absorbed by a user or bystander according to the
intended usage of the product. This product has been tested and found to comply with the
Technical Contacts and Enquiry: sales@scanmega.com
Website: www.scanmega.com
(This user manual / product specification is subjected to be changed without prior notice)
P.13
megascan M1 User Manual Rev. 1.0
Updated on 28th August, 2009
FCC criteria. The megascan M1 shall be installed & used such that parts of the user’s
body ther than the hands should be maintained at a comfortable distance of approximately
25 cm or more.
In some situations or environments, the use of wireless devices may be restricted by the
proprietor of the building or responsible representatives of the organization. These
situations may, for example, include the use of wireless equipment on board airplanes, or
in any other environment where the risk of interference to other devices or services is
perceived or identified as harmful.
If you are uncertain of the policy that applies on the use of wireless equipment in a specific
organization or environment (such as airports), you are encouraged to ask for
authorization to use this device prior to turning on the equipment.
Modifications
The FCC requires the user to be notified that any changes or modifications to this device
that are not expressly approved by the manufacturer may void the user’s authority to
operate the equipment. The correction of interference caused by unauthorized
modification, substitution or attachment will be the responsibility of the user. The
manufacturer and its authorized resellers or distributors are not liable for any damage or
violation of government regulations that may arise from failing to comply with these
guidelines.
Information for Professional Installers
All products must be professionally installed, and the transmit power of the system must
be adjusted by the professional installers to ensure that the system EIRP is in compliance
with the limit specified by the regulatory authority of the country of application.
See the following sections for more information:
Professional installers should select only the antenna types listed in the following table,
Frequency Band
Antenna Type
RFID; 900 MHz
Panel Antenna
The megascan M1 is only used with panel antenna. (model: MRD E42)
Technical Contacts and Enquiry: sales@scanmega.com
Website: www.scanmega.com
(This user manual / product specification is subjected to be changed without prior notice)
P.14
megascan M1 User Manual Rev. 1.0
Updated on 28th August, 2009
Chapter 3 Demonstration of RFID Applications
3.1 Creating RFID Application with megascan M1
Megabyte Ltd. megascan M1 is an intelligent reader and compliance with EPC global
C1G2/ISO 18000-6C, Users can develop own UHF RFID application on this platform.
3.1.1 Delivering Application to megascan M1
When the user wants to deliver applications to the megascan M1, they just
simply install the program in Windows XP and Linux platform.
3.1.2 Programming Language compatibility
Users may use several types of programming language, for examples,
C++, C#.NET, Java and Java script.
Technical Contacts and Enquiry: sales@scanmega.com
Website: www.scanmega.com
(This user manual / product specification is subjected to be changed without prior notice)
P.15
megascan M1 User Manual Rev. 1.0
Updated on 28th August, 2009
Chapter 4 Regulatory Information
4.1 Federal Communications Commission (FCC) Compliance
This equipment has been tested and found to comply with the limits for a class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
•
Reorient or relocate the receiving antenna
•
Increase the separation between the equipment and receiver
•
Consult the dealer or an qualified radio/TV technician for assistance
FCC NOTICE: To comply with FCC part 15 rules in the United States, the system must be
professionally installed to ensure compliance with the Part 15 certification. It is the
responsibility of the operator and professional installer to ensure that only certified
systems are deployed in the United States. The use of the system in any other
combination (such as co-located antennas transmitting the same information) is expressly
forbidden.
WARNING: DO NOT ATTEMPT TO SERVICE THE WIRELESS COMMUNICATION DEVICE
YOURSELF. SUCH ACTION MAY VOID THE WARRANTY. THE MEGASCAN M1 IS FACTORY
TUNED. NO CUSTOMER CALIBRATION OR TUNING IS REQUIRED. CONTACT MEGABYTE LTD.
TECHNICAL
SUPPORT
FOR
INFORMATION
ABOUT
SERVICING
YOUR
WIRELESS
COMMUNICATION DEVICE.
Note:
Changes or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
Technical Contacts and Enquiry: sales@scanmega.com
Website: www.scanmega.com
(This user manual / product specification is subjected to be changed without prior notice)
P.16
megascan M1 User Manual Rev. 1.0
Updated on 28th August, 2009
4.1.1 Radio Frequency Radiation Exposure
The highest RF output power of the unit was measured at 29.60dBm at 902.75
MHz. According to §1.1310 of the FCC rules, the power density limit for
General Population/Uncontrolled Exposure at 902.75 MHz is f(MHz)/1500 =
0.602mW/cm2. The
MPE is calculated to show the required separation distance that must be
maintained during installation to maintain compliance with the power density
limit. The minimum required cable length is 1.5m to be used with this device.
The following formula was used to calculate the Power Density:
S=
Where:
S = Power Density
P = Power input to the external antenna (Output power from the EUT antenna
Port(dBm) – cable loss(dB))
G = Gain of Transmit Antenna (Linear gain)
R = Distance from Transmitting Antenna
The power density at 25cm separation is:
S=
For this device, the calculation is as follows:
P = 29.60dBm (Output power from the EUT antenna Port) – 0.75dB (Cable
Loss*)
= 28.85dBm (767.361mW)
*Cable Loss = (0.75dB) : 1.5m long of 0.5dB/m loss
G = Worst Case Antenna Gain = 6dB = anti-log(6.0/10) = 3.98
At 25cm separation,
S = ((767.361) x (3.98)) / (4π(25)2) = 0.389mW/cm2
Based on the above calculation for 25cm separation, the power density does
not exceed FCC limit of 0.602mW/cm2.
Technical Contacts and Enquiry: sales@scanmega.com
Website: www.scanmega.com
(This user manual / product specification is subjected to be changed without prior notice)
P.17
megascan M1 User Manual Rev. 1.0
Updated on 28th August, 2009
4.2 CE Compliance
This device has been tested to and conforms to the regulatory requirements of the
European Union and has attained CE Marking. The CE Mark is a conformity marking
consisting of the letters "CE". The CE Mark applies to products regulated by certain
European health, safety and environmental protection legislation. The CE Mark is
obligatory for products it applies to: the manufacturer affixes the marking in order to be
allowed to sell his product in the European market.
The CE Marking is not a quality-mark. Foremost, it refers to the safety rather than to the
quality of a product. Secondly, CE Marking is mandatory for the product it applies to,
whereas most quality markings are voluntary.
Technical Contacts and Enquiry: sales@scanmega.com
Website: www.scanmega.com
(This user manual / product specification is subjected to be changed without prior notice)
P.18
megascan M1 User Manual Rev. 1.0
Updated on 28th August, 2009
Chapter 5 Disclaimer Notice
Disclaimer Notice
The manufacturer shall not be liable for errors contained herein or for incidental or
consequential damages in connection with the furnishing, performance or use of this
material. This document contains proprietary information, which is protected by
international patent applications and copyright. All rights reserved. No part of this
document may be copied, reproduced or translated without prior written consent of the
manufacturer. The manufacturer reserves the right to revise this publication and to make
changes from time to time in the contents hereof without obligation to notify any person of
such revisions or changes. The manufacturer also reserves the right to change the
specifications without notice.
Technical Contacts and Enquiry: sales@scanmega.com
Website: www.scanmega.com
(This user manual / product specification is subjected to be changed without prior notice)
P.19
megascan M1 User Manual Rev. 1.0
Updated on 28th August, 2009
Chapter 6 Warranty
1.
Megabyte Ltd warrants to the User that the Products sold to the User will comply with their
published specifications and will be of satisfactory quality and that Megabyte Ltd is entitled
to sell the Products to the User. Megabyte Ltd warrants that for a period of twelve (12)
months from date of purchase (“the Warranty Period”), the products will be free from defects
in materials and workmanship.
2.
During the Warranty Period, Megabyte Ltd will repair, or if in Megabyte Ltd’s opinion
necessary replace, the defective product returned to Megabyte Ltd’s head office in Hong
Kong. The defective production must be returned in its original packaging and all shipping
and handling charges shall be borne by the Users.
3.
The Warranty Period shall not be extended by reason of any repair or replacement.
4.
Megabyte Ltd shall have no liability to the User for any damage to or defects in any of the
Products caused by fair wear and tear, improper use, negligent handling, failure to observe
this User Manual and the instructions accompanying the Products or any alterations
maintenance or repair to the Products by any person other than Megabyte Ltd, use of
non-Megabyte Ltd parts, accessories or equipment, or third party software which would
damage the Products.
5.
Unless in the case of any damage to or defect in the Products which would have been
apparent on reasonable visual inspection, the User notifies Megabyte Ltd of the same in
writing within 7 days after the date of purchase thereof, or in the case of any damage to or
defects in the Products which would not have been apparent on reasonable visual inspection
the User notifies Megabyte Ltd of the same in writing 7 days after the defect becomes
apparent to the User, the User shall not be entitled to reject the Products concerned.
6.
The User shall be responsible for properly storing and making back up copies of all data
which may be stored in the Products. Megabyte Ltd shall not be responsible for any lost of
data as a result of any repair or replacement.
7.
Except as expressly provided in this User Manual no warranty, condition, undertaking, or
term, express or implied, statutory or otherwise, as to the condition, quality, performance,
durability or fitness for purpose of the Products is given or assumed by Megabyte Ltd and all
such warranties, conditions, undertakings and terms are hereby excluded to the fullest extent
permitted by law.
Technical Contacts and Enquiry: sales@scanmega.com
Website: www.scanmega.com
(This user manual / product specification is subjected to be changed without prior notice)
P.20
megascan M1 User Manual Rev. 1.0
Updated on 28th August, 2009
Chapter 7 Support
Technical support/sales enquiry can be obtained from Megabyte Ltd.
Please email to: sales@scanmega.com
Technical Contacts and Enquiry: sales@scanmega.com
Website: www.scanmega.com
(This user manual / product specification is subjected to be changed without prior notice)
P.21

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Copy, Extract, Print high-res
XMP Toolkit                     : 3.1-701
Create Date                     : 2009:08:28 14:22:12Z
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2009:08:28 16:40:37+08:00
Metadata Date                   : 2009:08:28 16:40:37+08:00
Format                          : application/pdf
Creator                         : Jack Chan
Title                           : Microsoft Word - megascan M1 User Manual Rev1.1f.doc
Producer                        : GPL Ghostscript 8.15
Document ID                     : uuid:f081b5ab-b14d-4759-8a65-c0efd602ce73
Instance ID                     : uuid:4d5422d3-f625-41a2-997d-3708183257db
Page Count                      : 21
Author                          : Jack Chan
EXIF Metadata provided by EXIF.tools
FCC ID Filing: XEK-MEGASCANM1

Navigation menu