MEIAN Technology MC-535R Wireless digital PIR detector User Manual

Shenzhen Meian Technology Co.,Ltd . Wireless digital PIR detector

User Manual

Installation:①wide-angle: 12M * 12M detection angle of 110 degrees②flat curtain: 12M * 2M detection angle of 3 degrees③ceiling curtain: 6M * 1M detection angle of 3 degreesInstallation heightOperation condition:Operation temperature:-10℃~60℃﹤95%RHStorage temperature:20℃ ~60℃(4℉ ~140℉)Size::86(L)*45(W)*36(H)mm④ : 2~2.3M3.Installation3.1 NotesDon't face cold orheat directlyDon't face the sun-shine directlyDon't install nearelectric cablesDon't install on aunstable base  Don't face metal wallWall mounting wideangle lens view03m3m6m6m9m9m12m8m4m0Side view2.3m1.5m0.6m12m8m4m7.52316,52,,,8,0,,XXX1.IntroductionX3.2 Installation locationP/N:20170428A01X3.3 Change battery:2~2.3mDetectorUse double-sided adhesive to install the detector 2 to 2.3 meters from the ground, pay attention to the installation of PIR down.A, with a word screwdriver light top groove, pull out the bottom cover, remove the bottom cover. ++-B, remove the old battery, according to the marked polarity of the battery correctly into the battery.Fig.1 Appearance Fig.2 Internal StructurePIRLED Tamper switchBattery containerDIP switch   MC-535R is a PIR intruder detector for indoor use.It adopts precision cylindrical FRESNEL lens, can effectively improve energy saving, with high sensitivity and free of false alarm. By using advanced patented software, it can identify the real intruder and other interference factor which may result in false alarm. Pulse counting can be adjustable. It is widely use in various indoor applications, Built-in big capacity lithium battery, power-save mode.Its working life is up to 2 years or above.2.Specifications     Model:MC-535R     Maximum detection distance: 12m/25     Emitting distance: 120m (in the open area)     Infrared distance:     Working voltage: DC3V, 1*CR123A lithium battery     Alarm current: <20mA     Quiescent Current: 16µA~17µA      Infrared section (as shown at right)     Optical lens data sheet     Infrared area: 12 × 4 (typical)     Maximum coverage: 12m * 12m (39 * 39 feet) / 90 °     Emitting distance : 433MHz     Alarm indication: The LED indicator is on for 2~3 seconds.℃12m   Installation can choose to install wide-angle, flat curtain, ceiling curtain three ways, different installation  methods corresponding to the installation height and detection angle is different (see "2, specifications and technical parameters").-1-Wireless digital PIR detector User Manual
①Set the detector as test mode to proceed walk-test.②Walk accross the far edge of coverage area at the speed of 1step/second(about 0.75m/s). The LED will flash for seconds then alarm(see the right figure).③Do walk-test in opposite direction to confirm the boundary of both sides.Makesure the detection centre pointing to the centre of protected area.④Make sure the detection centre at the proper place,should properly adjust thedetection area if you can not get an ideal detection area.⑤After adjust the detection angle, should re-do walk test as above.   6. Walking test in coverage area:7.Customer Service⑥After passing the test, be sure to set the alarm delay to 5 minutes mode, otherwise it will affect the battery life。For any help please contact with our company and you could visit our website for more information 5. Coding method between detector and panel:Coding setting:①Set the detector as normal mode, place the battery and LED will flashseconds,set the panel as coding mode(panel coding setting pls referto panel manual), within 3 seconds when press the confirm key of the panelWave hand near the front side of detector, it will send a alarm signalto the panel, if the panel sounds a response then code successfully.②Enter the address number to code with panel,set the panel as manual codingmode and enter the 9-digit address number,this method is much better.C, the side of the shell with a battery up one end, the bottom cover with a button at one end down the face of the shell to close and pull the bottom cover into the face shell.Tamper switch4.DIP switch function description123ON KE123OFF ONLow sensitivity High sensitivity(default)Alarm delay 5 minutes(default)LED is on(default)LED is offSwitch serialnumberAlarm delay 5 second-2-Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:-- Reorient or relocate the receiving antenna.-- Increase the separation between the equipment and receiver.-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.-- Consult the dealer or an experienced radio/TV technician for help .FCC WARNINGThis device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:(1) this device may not cause harmful interference, and(2) this device must accept any interference received, including interference that may cause undesired operation.

Navigation menu