OPERATING INSTRUCTIONS    FOR OEM USE ONLY© 2013 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.16 / 28SETTING CELSIUS OR FAHRENHEIT1  2ONAMPMOFFTo change between °C and °F, press and   buttons simultaneously.NOTE:  Choosing °F results in a 12 hour clock. Choosing °C results in a 24 hour clock.SETTING THE TIME1  2ONAMPMOFF1.   Press   and   buttons simultane-ously. Hour fl ashes.2. To select hour press   or   button.3.   Press   and   buttons simultane-ously. Minutes fl ash.4.  To select minutes press   or   but-ton.5.  To  confi rm  press   and   buttons simultaneously or wait.MODES OF OPERATION1  2ONAMPMOFFEnter Mode Press the appropriate mode button. Exit Mode1.  Press the same mode button again to change to Manual mode.2.   Press   or   button to change to Manual mode.3.  Press a different mode button to change to that mode.1  2ONAMPMOFFThermostatic Mode The room temperature is measured and compared to the set temperature. The fl ame  height  is  then  automatically  ad-justed to achieve the set temperature.1  2ONAMPMOFFProgram Mode Programs 1 and 2, each can be pro-grammed to go ON and OFF at specifi c times at a set temperature. 6-SYMBOLFigure 21: 6-symbol DisplayProgram ModeTemperatureTimeCountdown TimerBattery StatusSignal Indicator Child ProofThermostatic Mode1  2ONAMPMOFF°F or °C
OPERATING INSTRUCTIONS  FOR OEM USE ONLY© 2013 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.17 / 286-SYMBOLMANUAL MODE (HANDSET)NOTICEBEFORE OPERATING1.  Make sure MANUAL knob on the GV60 Valve is in the ON, full counterclockwise   position. 2.  Place the ON/OFF switch (if equipped) in the “I” (ON position).TO TURN ON FIRE When pilot ignition is confi rmed, motor turns automatically to maximum fl ame height.1  2ONAMPMOFFHandset▪   Press   button until a short beep con-fi rms  the  start  sequence  has  begun; release button. ▪   Continuing beeps confi rm ignition is in process.▪   Rotating circle is shown on display un-til ignition sequence is complete.▪   There is main gas fl ow once pilot igni-tion is confi rmed.▪   Handset automatically goes into Man-ual mode after main burner ignition.If the pilot does not stay lit after several tries, turn the main valve knob to OFF and follow the instructions “TURN OFF GAS TO APPLIANCE” (page 28).Standby Mode (Pilot Flame)Handset▪  Press and hold   button to set appliance to pilot fl ame.TO TURN OFF FIRE1  2ONAMPMOFFHandset▪  Press   button to turn off.NOTE:  There is a 5 sec delay before the next ignition is possible.FLAME HEIGHT ADJUSTMENT1  2ONAMPMOFFHandset▪   To  increase  fl ame  height  press  and hold   button.▪  To decrease fl ame height or to set ap-pliance to pilot fl ame, press and hold  button.DESIGNATED LOW FIRE AND HIGH FIREAM▪   To  go  to low fi re, double-click   but-ton. “LO” is displayed.NOTE:  Flame goes to high fi re fi rst be-fore going to low fi re.AM▪   To go to high fi re, double-click   but-ton. “HI” is displayed.If the appliance will not operate, follow the instructions “TURN OFF GAS TO APPLIANCE” (page 28).THERMOSTATIC MODE1  2ONAMPMOFFON: Press   button. Thermostat icon dis-played, preset temperature displayed briefl y,  and  then  room  temperature  dis-played.OFF: 1.   Press   button.2.   Press   or   button to enter Manual mode.3.   Press   button to enter Countdown Timer mode.1  2ONAMPMOFFSETTING: 1.   Press   button and hold until Ther-mostat icon displayed, temperature fl ashes.2.  To adjust SET temperature press   or   button.3. To confi rm press   button or wait.
OPERATING INSTRUCTIONS    FOR OEM USE ONLY© 2013 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.18 / 281  2ONAMPMOFFTime SETTING: 1.   Press   button and hold until  ,  ,  displayed, hour fl ashes.2.  To select hour press   or   button.3.  To confi rm press   button.  ,  dis-played, minutes fl ash.4.  To select minutes press   or   but-ton.1  2ONAMPMOFF5.  To confi rm press   button.  ,  ,  displayed, hour fl ashes.6. To select hour, press   or   button.7.  To confi rm press   button.  ,  ,  displayed, minutes fl ash.8.  To select minutes press   or   but-ton.NOTE:  If you stop programming at this point, program 2 remains deactivated.NOTE:  Programs 1 and 2 use the same ON (Thermostatic) and OFF temperatures.1  2ONAMPMOFF1.  To continue to program , press   button.  , ,   displayed, hour fl ashes.2.  To select hour press   or   button.3.  To confi rm press   button.  , ,  displayed, minutes fl ash.4.   To  select  minutes, press   or   but-ton.5.  To  confi rm  press   button.  , ,  displayed, hour fl ashes.6.  To select hour, press   or   button.7.  To confi rm press   button.  , ,  displayed, minutes fl ash.  8.  To select minutes, press   or   but-ton.  9.  To confi rm press   button or wait.NOTE:  Programs   and  use the same ON and OFF tempera-tures. Once an ON and/or OFF temperature has been set, that temperature becomes the new default setting.CHILD PROOF1  2ONAMPMOFFON: To activate press   and   buttons si-multaneously. Children icon displayed and the handset is rendered inoper-able, except for the OFF function.OFF: To deactivate press   and   buttons simultaneously. Children icon disap-pears.COUNTDOWN TIMER1  2ONAMPMOFFON/SETTING: 1.  Press and hold   button until hour-glass icon displayed and hour fl ashes. 2.  To select hour press   or   button.3.  To confi rm press  button. Minutes fl ash.4.   To select minutes press   or   button.5.  To confi rm press   button or wait.OFF:  Press  button,  hourglass and count-down time disappear.NOTE:  At end of countdown time period, the fi re turns OFF. The CountdownTimer only works in Manual, Thermostatic, and Random modes. Maximum countdown time is 9 hours.PROGRAM MODENOTE:  The set temperature for Thermostatic Mode is the tem-perature for the ON time in Program Mode. Changing the Thermostatic Mode set temperature also changes the ON time temperature in Program Mode.1  2ONAMPMOFFON: Press   button.  ,   or , ON or OFF displayed. 1  2ONAMPMOFFOFF: 1.   Press   or   or   button to enter Manual mode.2.   Press   button to enter Thermostatic mode.3.  Press Random icon button to enter Random mode.1  2ONAMPMOFFPROGRAM Temperature SETTING: 1.   Press   button and hold until  ,  , Set temperature (Thermostatic) displayed.2.  To continue press   button.  ,   displayed,  temperature  fl ashes  and wait.3.  To select OFF temperature press   or   button.4.  To confi rm press   button or wait.NOTE:  The  ON  (Thermostatic)  and  OFF  set  temperatures  are the same for each day.Program Mode
OPERATING INSTRUCTIONS  FOR OEM USE ONLY© 2013 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.19 / 281  2ONAMPMOFFSETTING CELSIUS OR FAHRENHEIT1  2ONAMPMOFFTo change between °C and °F, press and   buttons simultaneously.NOTE:  Choosing °F results in a 12 hour clock. Choosing °C results in a 24 hour clock.SETTING THE TIME1  2ONAMPMOFF1.   Press   and   buttons simultane-ously. Hour fl ashes.2. To select hour press   or   button.3.   Press   and   buttons simultane-ously. Minutes fl ash.4.  To select minutes press   or   but-ton.5.  To  confi rm  press   and   buttons simultaneously or wait.MODES OF OPERATION1  2ONAMPMOFFEnter Mode Press the appropriate mode button.   Exit Mode1.  Press the same mode button again to change to Manual mode.2.   Press   or   button to change to Manual mode.3.  Press a different mode button to change to that mode.1  2ONAMPMOFFThermostatic Mode The room temperature is measured and compared to the set temperature. The fl ame  height  is  then  automatically  ad-justed to achieve the set temperature.1  2ONAMPMOFFProgram Mode Programs 1 and 2, each can be pro-grammed to go ON and OFF at specifi c times at a set temperature. 8-SYMBOLFigure 22: 8-symbol DisplayProgram ModeTemperatureTimeAuxiliary FeatureCountdown TimerBattery StatusSignal Indicator Child ProofRandom ModeThermostatic Mode°F or °C 8-SYMBOL
OPERATING INSTRUCTIONS    FOR OEM USE ONLY© 2013 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.20 / 28AMRandom ModeFlame height changes automatically.NOTE: Mains adapter recommended. MANUAL MODE (HANDSET)NOTICEBEFORE OPERATING1.  Make sure MANUAL knob on the GV60 Valve is in the ON, full counterclockwise   position. 2.  Place the ON/OFF switch (if equipped) in the “I” (ON position).TO TURN ON FIRE When pilot ignition is confi rmed, motor turns automatically to maximum fl ame height.1  2ONAMPMOFFHandset▪   Press   button until a short beep con-fi rms  the  start  sequence  has  begun; release button. ▪   Continuing beeps confi rm ignition is in process.▪   Rotating circle is shown on display un-til ignition sequence is complete.▪   There is main gas fl ow once pilot igni-tion is confi rmed.▪   Handset automatically goes into Man-ual mode after main burner ignition.If the pilot does not stay lit after several tries, turn the main valve knob to OFF and follow the instructions “TURN OFF GAS TO APPLIANCE” (page 28).Standby Mode (Pilot Flame)Handset▪  Press and hold   button to set appliance to pilot fl ame.TO TURN OFF FIRE1  2ONAMPMOFFHandset▪  Press   button to turn off.NOTE:  There is a 5 sec delay before the next ignition is possible.FLAME HEIGHT ADJUSTMENT1  2ONAMPMOFFHandset▪   To  increase  fl ame  height  press  and hold   button.▪  To decrease fl ame height or to set ap-pliance to pilot fl ame, press and hold  button.DESIGNATED LOW FIRE AND HIGH FIREAM▪   To  go  to low fi re, double-click   but-ton. “LO” is displayed.NOTE:  Flame goes to high fi re fi rst be-fore going to low fi re.AM▪   To go to high fi re, double-click   but-ton. “HI” is displayed.If the appliance will not operate, follow the instructions “TURN OFF GAS TO APPLIANCE” (page 28).
OPERATING INSTRUCTIONS  FOR OEM USE ONLY© 2013 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.21 / 281  2ONAMPMOFFOFF: 1.   Press   or   or   button to enter Manual mode.2.   Press   button to enter Thermostatic mode.3.  Press Random icon button to enter Random mode.1  2ONAMPMOFFPROGRAM Temperature SETTING: 1.   Press   button and hold until  ,  , Set temperature (Thermostatic) displayed.2.  To continue press   button.  ,   displayed,  temperature  fl ashes  and wait.3.  To select OFF temperature press   or   button.4.  To confi rm press   button or wait.NOTE:  The  ON  (Thermostatic)  and  OFF  set  temperatures  are the same for each day.1  2ONAMPMOFFTime SETTING: 1.   Press   button and hold until  ,  ,  displayed, hour fl ashes.2.  To select hour press   or   button.3.  To confi rm press   button.  ,  dis-played, minutes fl ash.4.  To select minutes press   or   but-ton.1  2ONAMPMOFF5.  To confi rm press   button.  ,  ,  displayed, hour fl ashes.6. To select hour, press   or   button.7.  To confi rm press   button.  ,  ,  displayed, minutes fl ash.8.  To select minutes press   or   but-ton.NOTE:  If you stop programming at this point, program 2 remains deactivated.NOTE:  Programs 1 and 2 use the same ON (Thermostatic) and OFF temperatures.THERMOSTATIC MODE1  2ONAMPMOFFON: Press   button. Thermostat icon dis-played, preset temperature displayed briefl y, and then room temperature dis-played.OFF: 1.   Press   button.2.   Press   or   button to enter Manual mode.3.   Press   button to enter Countdown Timer mode.4.   Press   button to enter Random mode.1  2ONAMPMOFFSETTING: 1.   Press   button and hold until Ther-mostat icon displayed, temperature fl ashes.2.  To adjust SET temperature press   or   button.3. To confi rm press   button or wait.COUNTDOWN TIMER1  2ONAMPMOFFON/SETTING: 1.  Press and hold   button until hour-glass icon displayed and hour fl ashes. 2.  To select hour press   or   button.3.  To  confi rm  press   button. Minutes fl ash.4.   To select minutes press   or   but-ton.5. To confi rm press   button or wait.OFF:  Press   button,  hourglass and count-down time disappear.NOTE:  At end of countdown time period, the fi re turns OFF. The CountdownTimer only works in Manual, Thermostatic, and Random modes. Maximum countdown time is 9 hours.PROGRAM MODENOTE:  The set temperature for Thermostatic Mode is the tem-perature for the ON time in Program Mode. Changing the Thermostatic Mode set temperature also changes the ON time temperature in Program Mode.1  2ONAMPMOFFON: Press  button.  ,   or , ON or OFF displayed. 8-SYMBOL
OPERATING INSTRUCTIONS    FOR OEM USE ONLY© 2013 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.22 / 28CHILD PROOF1  2ONAMPMOFFON: To activate press   and   buttons si-multaneously. Children icon displayed and the handset is rendered inoper-able, except for the OFF function.OFF: To deactivate press   and   buttons simultaneously. Children icon disap-pears.1  2ONAMPMOFF1.  To continue to program , press   button.  , ,   displayed, hour fl ashes.2.  To select hour press   or   button.3.  To confi rm press   button.  , ,  displayed, minutes fl ash.4.   To  select  minutes, press   or   but-ton.5.  To  confi rm  press   button.  , ,  displayed, hour fl ashes.6.  To select hour, press   or   button.7.  To confi rm press   button.  , ,  displayed, minutes fl ash.  8.  To select minutes, press   or   but-ton.  9.  To confi rm press   button or wait.NOTE:  Programs   and  use the same ON and OFF tempera-tures. Once an ON and/or OFF temperature has been set, that temperature becomes the new default setting.RANDOM FLAMEAMON: Press   button. Random icon dis-played.OFF: Press   button. Random icon disap-pears.NOTE: Mains adapter recommended. AUXILIARY FEATUREUpon ignition burner 1 is ON and burner 2 is in the last setting.1  2ONAMPMOFFOFF:   To switch the burner OFF, press the  button (Auxiliary icon disappears).ON: To switch a burner ON, press the   but-ton.NOTE:  The latching solenoid valve cannot operate manually. If the receiver battery runs down it will remain in the last operating position. Program Mode
OPERATING INSTRUCTIONS  FOR OEM USE ONLY© 2013 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.23 / 28SETTING CELSIUS OR FAHRENHEIT1  2ONAMPMOFFTo change between °C and °F, press and   buttons simultaneously.NOTE:  Choosing °F results in a 12 hour clock. Choosing °C results in a 24 hour clock.SETTING THE TIME1  2ONAMPMOFF1.   Press   and   buttons simultane-ously. Hour fl ashes.2. To select hour press   or   button.3.   Press   and   buttons simultane-ously. Minutes fl ash.4.  To select minutes press   or   but-ton.5.  To  confi rm  press   and   buttons simultaneously or wait.MODES OF OPERATION1  2ONAMPMOFFEnter Mode Press the appropriate mode button.   Exit Mode1.  Press the same mode button again to change to Manual mode.2.   Press   or   button to change to Manual mode.3.  Press a different mode button to change to that mode.1  2ONAMPMOFFThermostatic Mode The room temperature is measured and compared to the set temperature. The fl ame  height  is  then  automatically  ad-justed to achieve the set temperature.1  2ONAMPMOFFProgram Mode Programs 1 and 2, each can be pro-grammed to go ON and OFF at specifi c times at a set temperature. 10-SYMBOLFigure 23: 10-symbol DisplayLightFanProgram ModeTemperatureTimeAuxiliary FeatureCountdown TimerBattery StatusSignal Indicator Child ProofRandom ModeThermostatic Mode1  2ONAMPMOFF°F or °C 10-SYMBOL
OPERATING INSTRUCTIONS    FOR OEM USE ONLY© 2013 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.24 / 28AMRandom ModeFlame height changes automatically.NOTE: Mains adapter recommended. MANUAL MODE (HANDSET)NOTICEBEFORE OPERATING1.  Make sure MANUAL knob on the GV60 Valve is in the ON, full counterclockwise   position. 2.  Place the ON/OFF switch (if equipped) in the “I” (ON position).TO TURN ON FIRE When pilot ignition is confi rmed, motor turns automatically to maximum fl ame height.1  2ONAMPMOFFHandset▪   Press   button until a short beep con-fi rms  the  start  sequence  has  begun; release button. ▪   Continuing beeps confi rm ignition is in process.▪   Rotating circle is shown on display un-til ignition sequence is complete.▪   There is main gas fl ow once pilot igni-tion is confi rmed.▪   Handset automatically goes into Man-ual mode after main burner ignition.If the pilot does not stay lit after several tries, turn the main valve knob to OFF and follow the instructions “TURN OFF GAS TO APPLIANCE” (page 28).Standby Mode (Pilot Flame)Handset▪  Press and hold   button to set appliance to pilot fl ame.TO TURN OFF FIRE1  2ONAMPMOFFHandset▪  Press   button to turn off.NOTE:  There is a 5 sec delay before the next ignition is possible.FLAME HEIGHT ADJUSTMENT1  2ONAMPMOFFHandset▪   To  increase  fl ame  height  press  and hold   button.▪  To decrease fl ame height or to set ap-pliance to pilot fl ame, press and hold  button.DESIGNATED LOW FIRE AND HIGH FIREAM▪   To  go  to low fi re, double-click   but-ton. “LO” is displayed.NOTE:  Flame goes to high fi re fi rst be-fore going to low fi re.AM▪   To go to high fi re, double-click   but-ton. “HI” is displayed.If the appliance will not operate, follow the instructions “TURN OFF GAS TO APPLIANCE” (page 28).
OPERATING INSTRUCTIONS  FOR OEM USE ONLY© 2013 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.25 / 281  2ONAMPMOFFOFF: 1.   Press   or   or   button to enter Manual mode.2.   Press   button to enter Thermostatic mode.3.  Press Random icon button to enter Random mode.1  2ONAMPMOFFPROGRAM Temperature SETTING: 1.   Press   button and hold until  ,  , Set temperature (Thermostatic) displayed.2.  To continue press   button.  ,   displayed,  temperature  fl ashes  and wait.3.  To select OFF temperature press   or   button.4.  To confi rm press   button or wait.NOTE:  The  ON  (Thermostatic)  and  OFF  set  temperatures  are the same for each day.1  2ONAMPMOFFTime SETTING: 1.   Press   button and hold until  ,  ,  displayed, hour fl ashes.2.  To select hour press   or   button.3.  To confi rm press   button.  ,  dis-played, minutes fl ash.4.  To select minutes press   or   but-ton.1  2ONAMPMOFF5.  To confi rm press   button.  ,  ,  displayed, hour fl ashes.6. To select hour, press   or   button.7.  To confi rm press   button.  ,  ,  displayed, minutes fl ash.8.  To select minutes press   or   but-ton.NOTE:  If you stop programming at this point, program 2 remains deactivated.NOTE:  Programs 1 and 2 use the same ON (Thermostatic) and OFF temperatures.THERMOSTATIC MODE1  2ONAMPMOFFON: Press   button. Thermostat icon dis-played, preset temperature displayed briefl y, and then room temperature dis-played.OFF: 1.   Press   button.2.   Press   or   button to enter Manual mode.3.   Press   button to enter Countdown Timer mode.    4.   Press   button to enter Random mode.1  2ONAMPMOFFSETTING: 1.   Press   button and hold until Ther-mostat icon displayed, temperature fl ashes.2.  To adjust SET temperature press   or   button.3. To confi rm press   button or wait.COUNTDOWN TIMER1  2ONAMPMOFFON/SETTING: 1.  Press and hold   button until hour-glass icon displayed and hour fl ashes. 2.  To select hour press   or   button.3.  To  confi rm  press   button. Minutes fl ash.4.   To select minutes press   or   but-ton.5. To confi rm press   button or wait.OFF:  Press   button,  hourglass and count-down time disappear.NOTE:  At end of countdown time period, the fi re turns OFF. The CountdownTimer only works in Manual, Thermostatic, and Random modes. Maximum countdown time is 9 hours.PROGRAM MODENOTE:  The set temperature for Thermostatic Mode is the tem-perature for the ON time in Program Mode. Changing the Thermostatic Mode set temperature also changes the ON time temperature in Program Mode.1  2ONAMPMOFFON: Press   button.  ,   or , ON or OFF displayed. 10-SYMBOL
OPERATING INSTRUCTIONS    FOR OEM USE ONLY© 2013 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.26 / 28RANDOM FLAMEAMON: Press   button. Random icon dis-played.OFF: Press   button. Random icon disap-pears.NOTE: Mains adapter recommended. AUXILIARY FEATUREUpon ignition burner 1 is ON and burner 2 is in the last setting.1  2ONAMPMOFFOFF:   To switch the burner OFF, press the  button (Auxiliary icon disappears).ON: To switch a burner ON, press the   but-ton.NOTE:  The latching solenoid valve cannot operate manually. If the receiver battery runs down it will remain in the last operating position. CHILD PROOF1  2ONAMPMOFFON: To activate press   and   buttons si-multaneously. Children icon displayed and the handset is rendered inoper-able, except for the OFF function.OFF: To deactivate press   and   buttons simultaneously. Children icon disap-pears.1  2ONAMPMOFF1.  To continue to program , press   button.  , ,   displayed, hour fl ashes.2.  To select hour press   or   button.3.  To confi rm press   button.  , ,  displayed, minutes fl ash.4.   To  select  minutes, press   or   but-ton.5.  To  confi rm  press   button.  , ,  displayed, hour fl ashes.6.  To select hour, press   or   button.7.  To confi rm press   button.  , ,  displayed, minutes fl ash.  8.  To select minutes, press   or   but-ton.  9.  To confi rm press   button or wait.NOTE:  Programs   and  use the same ON and OFF tempera-tures. Once an ON and/or OFF temperature has been set, that temperature becomes the new default setting.CIRCULATING FAN OPERATIONAM NOTE:  SETTING only. Fan is switched ON automatically when gas opens. Circulating fan has 4 speed levels from low (1 bar) to high (4 bars).SETTING:  1.   Press   button and hold until fan icon fl ashes.2.   Press   button to increase fan speed and   button to decrease fan speed.3.  To confi rm setting either press   but-ton or wait (Fan icon displayed). OFF:    Press   button until all 4 speed level bars disappear.LIGHT/DIMMER OPERATIONAMON: Press    button  (light  icon  displayed). Light is on at preset level.OFF: Press   button (light icon disappears).  SETTING:  1.   Press  button and hold until light icon fl ashes.2.  To adjust light between 20…100 % press   or   button.  3.  To confi rm setting either press   but-ton or wait (Light icon displayed).NOTE:  The Light works independently of the Pilot fl ame. If you want the light ON but no fl ame, press   button.
OPERATING INSTRUCTIONS  FOR OEM USE ONLY© 2013 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.27 / 28TOUCH PAD / WALL SWITCHTo Turn ON Appliance ▪  Press   button  (see  fi gure  24)  until  a  short  beep  con-fi rms the start sequence has begun; release button.▪  Continuing beeps confi rm the ignition is in process.▪  Once pilot ignition is confi rmed, there is main gas fl ow.If the  pilot does not stay lit after several tries, turn  the main valve knob to OFF and follow the instructions “TO TURN OFF GAS TO APPLIANCE” (page 28).STANDBY MODE (PILOT FLAME)▪  Press and hold   (small fl ame) button to set appliance at pilot fl ame.To Turn OFF Appliance▪  Press  button.Flame Height Adjustment▪  Press and hold   (large fl ame) button to increase fl ame height.▪  Press and hold   (small fl ame) button to decrease fl ame height or to set appliance at pilot fl ame.▪  For fi ne adjustment tap   (large fl ame) or   (small fl ame) button.If  the  appliance  will  not  operate,  follow  the  instructions  “TO TURN OFF GAS TO APPLIANCE” (page 28).TO OPEN AND CLOSE SOLENOID VALVE/BURNER ▪  Upon ignition Main Burner and Decorative Burner are ON.▪  Simultaneously press the  and   (small fl ame) buttons to switch the Decorative Burner OFF.▪  Simultaneously press  and   (large fl ame) buttons but-tons to switch Decorative Burner ON. NOTE:  The latching solenoid valve cannot operate manually. If the receiver battery runs down it will remain in the last operating position. During normal operation the solenoid valve will be reset to the ON position when the GV60 is switched OFF remotely.Figure 25: Switch PanelA)  Increase fl ame heightB) ON/OFFC)  Decrease fl ame heightSWITCH PANEL To Turn ON Appliance ▪  Press “B” button (see fi gure 25) until a short beep confi rms the start sequence has begun; release button.▪  Continuing beeps confi rm the ignition is in process.▪  Once pilot ignition is confi rmed, there is main gas fl ow.If the  pilot does not stay lit after several tries, turn  the main valve knob to OFF and follow the instructions “TO TURN OFF GAS TO APPLIANCE” (page 28).STANDBY MODE (PILOT FLAME)▪  Press and hold “C” button to set appliance at pilot fl ame.To Turn OFF Appliance▪  Press “B” button.Flame Height Adjustment▪  Press and hold “A” button to increase fl ame height.▪  Press and  hold  “C” button to  decrease  fl ame height  or  to  set appliance at pilot fl ame.▪  For fi ne adjustment tap button “A” or “C” button.If  the  appliance  will  not  operate,  follow  the  instructions  “TO TURN OFF GAS TO APPLIANCE” (page 28).Increase fl ame heightON-OFFDecrease fl ame heightFigure 24: Touch  Pad / Wall  Switch
OPERATING INSTRUCTIONS    FOR OEM USE ONLY© 2013 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.28 / 28MANUAL OPERATION (Only possible, when MANUAL knob is used)Access to the pilot burner is only required for ignition with a match.When turning main valve knob, do not force. Knob has a slip clutch that clicks until the end stops are reached. This allows for manual  fl ame height  adjustment  as  well  as  adjustment  to  pilot standby position.1.  STOP! Read the safety information included before proceeding.2.  Turn main valve knob to the OFF, full clockwise   position.3.  Turn MANUAL knob to the MAN, full clockwise   position.4.   Place ON/OFF switch (if equipped) in O (OFF position).5.  Wait fi ve (5) minutes to clear out any gas. Verify that no gas is in  the  area around  the  appliance, including  near  the fl oor. If you detect gas STOP! Follow “WHAT TO DO IF YOU SMELL GAS” in the safety information on page 2. If no gas is present, proceed to step 6.6.  Place ON/OFF switch (if equipped) in “I” (ON position).7.  With the MANUAL knob in MAN position a manual pilot valve operator and piezo ignitor (optional) are accessible.8.  Fully push down manual pilot valve operator and hold in, to start pilot gas fl ow (see fi gure 25).   Ignition with match:   Immediately  light  the  pilot  with  a  match,  while  continuing  to hold in the manual pilot valve operator for about one (1) minute after the pilot is lit. Release manual pilot valve operator. If pilot does not stay lit, wait fi ve (5) minutes and repeat.  Ignition with piezo ignitor:   Change the ignition cable from the receiver to the valve (see fi gure 25). Push in the piezo ignitor to ignite. If pilot does not stay lit, wait fi ve (5) minutes and repeat.If  the  pilot  does  not  stay  lit  after  several  tries,  turn  the  gas control knob (main valve knob) to OFF and proceed to step 12. Figure 25: Combination control, cover8 Wire Receiver jackMicroswitchMANUAL knobin MAN positionMain valve knobin OFF positionManual pilot valve operatorPiezo ignitor(optional)ON/OFF switch(optional) inON PositionConnectionpiezo ignitor tab 2.8 x 0.8 mm9.   If applicable, replace pilot access panel before proceeding.10.  Turn MANUAL knob to the ON, full counterclockwise   position.11.  Turn main valve knob to the full ON, full counterclockwise  position.12.  If the appliance will not operate, follow the instructions “TO TURN OFF GAS TO APPLIANCE” (below).TO TURN OFF GAS TO APPLIANCE1. Place ON/OFF switch (if equipped) in O (OFF position).2.  If gas control is accessible turn main valve knob to the OFF full clockwise   position.3. Replace appliance access cover (if applicable).AUTOMATIC TURN DOWN3 Hour No Communication Function▪  The valve will turn to  pilot  fl ame if there is  no communication between handset and receiver for a 3 hour period. The fi re will continue to function normally when communication is restored. Receiver Overheating(only if module is connected)▪  Valve turns to  pilot  fl ame if  the  temperature in the receiver  is higher  than  140 °F  (60 °C).  The  main burner  turns back ON (manually or in thermostatic mode) only when the temperature is below 140 °F (60 °C).1 Hour Turn Down for Special Receiver (bedroom fi replaces only)▪  The valve will turn to pilot fl ame if there is no change in fl ame height over a 1 hour period.AUTOMATIC SHUT OFFCountdown Timer▪    At end of countdown time period, the fi re turns OFF. The Count-downTimer only works in Manual, Thermostatic, and Random modes. Maximum countdown time is 9 hours.Low Battery Receiver▪  With low battery power in the receiver the system shuts off the fi re completely. This will not happen if the power supply is inter-rupted.Five Day Shut Off (CSA version)▪  The system shuts off the fi re completely if there is no change in fl ame height for 5 days.2nd Thermocouple Shut Off▪  2nd thermocouple Option: The system shuts OFF the fi re if the main burner does not completely ignite approximately 20 sec-onds after ignition or after pushing   button.NOTE:  Before the next ignition there is a 2 minute waiting period.Exclusive Distributor North America for Mertik MaxitrolMaxitrol Company, Inc.23555 Telegraph Rd., PO Box 2230, Southfield, MI 48037-2230, USATel: +1 248-356-1400, Fax: +1 248-356-0829www.maxitrol.comMertik Maxitrol GmbH & Co. KGWarnstedter Str. 3, 06502 Thale, GermanyTel: + 49 3947 400-0, Fax: + 49 3947 400-200www.mertikmaxitrol.comRRGV60-II.OI-EN-10.2013-Symax