PRODUCT: ASSSEMBLY PART NUMBER: REV:
Puma
ASSEMBLY INSTRUCTION
FOR
LAN Radio and Meter
ASSY# PRD0900
CREATED BY: DATE:
Kent Vogel 11/12/02
APPROVED: DATE:
METERING TECHNOLOGY
Carlos Cuturrufo 02 CORPORATION
APPROVED: DATE:
Scotts Valley, CA
QA:
Kent Vogel
DATE:
02
DATE: DOCUMENT NUMBER: REVISION: PAGE OF
11/12/02 ASI0021 A 1 2
FORM: xxxxxxxxxxxx
Tested and Report Prepared By: FCC ID PDVRFLAN
ITC Engineering Services
9959Calaveras Road, Box 543
Sunol, CA 94586-0543
Tel: 925-862-2944 Fax: 925-862-9013
Email: docs@itcemc.com Web: www.itcemc.com
MTC CONFIDENTIAL INFORMATION
PRODUCT: ASSSEMBLY PART NUMBER: REV:
Puma
DATE: DOCUMENT NUMBER: REVISION: PAGE OF
11/12/02 ASI0021 A 2 2
FORM: xxxxxxxxxxxx
DOCUMENT REVISION HISTORY
DOC
REV
REASON FOR CHANGE DESCRIPTION OF CHANGE DATE
A Initial Release Release of Instruction 11-12-2002
Procedure:
1. Place the meterboard on the top of the base assembly. Attach the power connector
assembly, CT connector assembly, and battery to the meterboard. Snap the meterboard
onto the base skirt.
2. Attach the display bracket to the top of the board. Install the flex cable from the LCD
to the meterboard, then snap the LCD into the display bracket.
3. Install the LAN radio card to the side of the base skirt using the plastic plunger rivets.
4. Install the LAN antenna board to the display bracket using the pine tree rivets.
5. Connect the flex circuit between the LAN radio and the meterboard.
6. Solder the coax cable between the LAN antenna and the LAN radio.
7. Install the cover seal to the base rib.
8. Place the bezel over the meter base and align the slots so that it snaps into place onto
the base skirt.
9. Add label with the following notation: « Contains FCC ID: PDVRFLAN », MTC p/n.
XXXXXXXXX to the top surface of the meter bezel
10. Install the cover assembly as the final step to the meter.