Mettler Toledo QLX45MODULE Liquid Dosing Unit with RFID reader User Manual Quantos Automated Dosing
Mettler-Toledo GmbH Liquid Dosing Unit with RFID reader Quantos Automated Dosing
Contents
- 1. user manual
- 2. Operating instructions
user manual
User Manual Quantos Automated Dosing Liquid Module Overview Liquid module Legend Liquid Module Pump module with bottle Pump module (QL2) Liquid dosing head support Bottle Quantos Automated Dosing Liquid kit with liquid dosing head (QLL1000) Top glass liquid Liquid dosing head (QL001) Liquid kit (QLX45) ErgoClip vial 1 Safety Information Read and understand the instructions in this manual before you use the device. Keep this manual for future reference. • Include this manual if you pass on the device to other parties. If the device is not used according to the instructions in this manual or if it is modified, the safety of the user may be impaired and Mettler-Toledo GmbH assumes no liability. • • 1.1 Definition of signal words and warning symbols Signal Words WARNING for a hazardous situation with medium risk, possibly resulting in death or severe injury if not avoided. CAUTION for a hazardous situation with low risk, resulting in minor or moderate injury if not avoided. NOTICE for a hazardous situation with low risk, resulting in damage to the instrument, other material damage, malfunctions and erroneous results, or loss of data. Note (no symbol) for useful information about the product. Symbols General hazard Electrical shock Inflammable or explosive substance Explosion Toxic substance 1.2 Product specific safety notes Your dosing system represents state-of-the-art technology and complies with all recognized safety rules, however, certain hazards may arise in extraneous circumstances. Do not open the device; it does not contain any parts that can be maintained, repaired or replaced by the user. If you experience problems with your dosing system, contact your authorized METTLER TOLEDO dealer or service representative. The dosing system has been tested for the experiments and intended purposes documented in the appropriate manual. However, this does not absolve you from the responsibility of performing your own tests of the products supplied by us regarding their suitability for the methods and purposes you intend to use them for. Intended use This dosing system is designed to be used in analytical laboratories by qualified staff. Your dosing system is used for weighing and dosing powder or liquid samples. Use the dosing system exclusively for this purpose. Any other type of use and operation beyond the limits of technical specifications without written consent from Mettler-Toledo GmbH, is considered as not intended. Site requirements The balance has been developed for indoor operation in a well-ventilated area. Avoid the following environmental influences: • • • • Conditions outside of the ambient conditions specified in the technical data Powerful vibrations Direct sunlight Corrosive gas atmosphere Quantos Automated Dosing • • Explosive atmosphere of gases, steam, fog, dust and flammable dust Powerful electric or magnetic fields Staff qualification Incorrect use of the dosing system or the chemicals used in the analysis can lead to death or injury. The following experience is needed for operating the dosing system. • • • Knowledge and experience in working with toxic and caustic substances. Knowledge and experience in working with standard laboratory equipment. Knowledge and experience in working in accordance with general lab safety rules. Responsibilities of the dosing system owner The dosing system owner is the person that uses the dosing system for commercial use or places the dosing system at the disposal of his staff. The dosing system owner is responsible for product safety and the safety of staff, user(s) and third party. The operator has the following responsibilities: • • • • • Know the rules for safety at the workplace that are in effect and enforce them. Ensure that only qualified staff uses the dosing system. Define the responsibilities for installation, operation, cleaning, troubleshooting and maintenance and ensure that the tasks are done. Train the staff in regular intervals and inform them about dangers. Provide the necessary protective gear for the staff. Shut down of the instrument in emergency situations − Pull the plug from the electrical outlet. Protective clothing Wear protective clothing in the laboratory when working with hazardous or toxic substances. Wear suitable eye protection such as goggles. Use appropriate gloves when handling chemicals or hazardous substances and check their integrity before use. Wear a lab coat. Quantos Automated Dosing Safety notes WARNING Danger of death or serious injury due to electric shock! Contact with parts that contain a live current can lead to injury and death. If the device cannot be shut down in an emergency situations, people can be injured or the device can be damaged. 1 Only use the supplied three-core power cable with equipment grounding conductor to connect your device. 2 Check that the voltage printed on it is the same as your local power supply voltage. ð If this is not the case, under no circumstances connect the AC adapter to the power supply, but contact a METTLER TOLEDO representative. Only connect the instrument to a three-pin power socket with earthing contact. Only standardized extension cable with equipment grounding conductor must be used for operation of the device. Do not disconnection the equipment grounding conductor. Check the cables and the plug for damage and replace damaged cables and plugs. Make sure that the cables are arranged so that they cannot be damaged or interfere with the operation. Keep all electrical cables and connections away from liquids. Make sure that the power plug is accessible at all times. WARNING Danger of injuries and death due to toxic substances or caustic components! Chemicals can cause injuries if they come in contact with bare skin, eyes or are inhaled. 1 When using chemicals and solvents, comply with the instructions of the producer and the general lab safety rules. 2 Set up the instrument in a well-ventilated location. 3 Clean any spills immediately. 4 If you dry substances which form toxic gases, place the instrument in a fume hood. WARNING Damage of bottle or pump because of high pressure! If the bottle or the pump with a protective gas exposed to high pressure, the bottle or the pump module might get damaged. 1 Avoid pressure higher than 1.5 bar (21 psi) in the bottle. 2 Ensure the protective gas does not exceed the pressure range of 0.2 bar (2.9 psi). 3 Wear protective glasses when working with the bottle. WARNING Danger of death and serious injuries due to flammable solvents! Flammable solvents can ignite and lead to fire and explosions. 1 Keep flammable solvents away from naked flames. 2 When using chemicals and solvents, comply with the instructions of the producer and the general lab safety rules. Quantos Automated Dosing CAUTION Danger of injuries due to splashing liquids! Splashing liquids because of remaining pressure in dosing head. If you don't release the pressure of the dosing head, liquid might splash when opening dosing head or removing liquid tube. 1 Always release pressure of dosing head by switching off the instrument before removing liquid tube. 2 Wear protective glasses. NOTICE Environment Only use indoors in dry locations. NOTICE Danger of damage to the device! Never open the device. The device contains no user-serviceable parts. − In the event of problems, please contact a METTLER TOLEDO representative. NOTICE Danger of damage to the device due to incorrect parts! Using incorrect parts with the device can damage the device or cause the device to malfunction. − Only use parts supplied with the device, listed accessories and spare parts from Mettler-Toledo GmbH. Finding more information Refers to an external document. FCC Rules This device complies with Industry Canada licence-exempt RSS standard(s) and part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Quantos Automated Dosing 2 Design and Function 2.1 Dosing head Liquid dosing head This is the standard head for liquid dosing. It is used together with pump module and bottle. Manual dosing head The manual dosing head is used for manual powder dosing. It is equipped with a integrated RFID tag to store substance data and to provide printing data. Functional description As soon as a head is inserted, the instrument automatically reads the data of the head. In addition, the instrument performs automatic adjustments concerning the Dosing steps, automatic door operation and other instrument settings. When no dosing head is installed the instrument will replace head-specific information with factory settings. Quantos Automated Dosing 2.2 Data stored in the dosing head’s RFID Every dosing head is equipped with a integrated RFID tag (1) which stores and exchanges data with the instrument. The following data is stored in the RFID tag of the head: • • User data This block holds information about the substance such as the name of the substance, the filling and expiry dates, the quantity, etc. This data can be edited by the user at any time and should be entered before using a new head for the first time to have the data available for reports and labels. Quantos Automated Dosing 3 Installation and Putting into Operation Additional information about this instrument can be found in the Operating Instructions on the CD-ROM or online. Finding more information u www.mt.com/quantos The instrument is installed by METTLER TOLEDO service engineers. This includes the wiring as well as the configuration of the interfaces and peripherals. 3.1 Scope of delivery Liquid module Check the delivery for completeness. The following accessories are part of the standard equipment of the liquid module: • Liquid kit QLX45 • Liquid bottle and head QLL1000 – Liquid kit QLX45 – Liquid head QL001 – Top glass liquid – Bottle 1000 ml pressure resistant – ErgoClip vial – Bottle cap with fitting and support – SmartGrid round – Micro dosing valve tool – Vial adapter 5 pcs – Spare part set (incl. filter, ferrule, peek nut) – MinWeigh door – Liquid tube – Screwdriver torx T8 – RS232C-cable – Air tube • Pump module QL2 – RFID transponder 5 pcs – Pump QL2 – Power supply – Liquid side doors for QL2 – Cable conduct – Muffler – Cable clip (cable conduct closure) – Bottle holder – User Manual – Drip pan – CAN-cable 3.2 Selecting the location An optimal location will ensure accurate and reliable operation of the instrument. The surface must be able to safely take the weight of the instrument when fully loaded. The following local conditions must be observed: If the instrument is not horizontal at the outset, it must be leveled during commissioning. • • • • • • • 10 The instrument must only be used indoors and up to a maximum altitude of 4000 m above sea level. Before switching on the balance, wait until all parts are at room temperature (+5 to 40 °C). The humidity must be between 10% and 80% non-condensing. The power plug must be accessible at all times. Firm, horizontal and vibration-free location. Avoid direct sunlight. No excessive temperature fluctuations. No strong drafts. Quantos Automated Dosing 3.3 Assembling the liquid module Assemble the balance according to your XPE Operating Instructions. 1 Remove top glass (1) by sliding it backwards and pulling it upwards (2) carefully. 2 Insert the liquid kit (1), pull 2 levers (2) towards you and slide liquid kit onto the rack. Note CAN-connector is on bottom of liquid kit. 3 To fix position of liquid kit, release 2 levers (2) and move liquid kit slightly. ð Liquid kit locks down. ð Liquid kit is mounted. 4 Insert the top glass liquid (1) into the rear guide. 5 Carefully fold top glass liquid (2) downwards. 3.4 Assembling pump module and bottle WARNING Damage of bottle because of high pressure! If the bottle has to resist higher pressure than 1.5 bar (21 psi) it might get damaged. 1 Avoid pressure higher than 1.5 bar (21 psi) in the bottle. 2 Wear protective glasses when working with the bottle. Quantos Automated Dosing 11 − Mount pump module and bottle according to figure. Inserting and removing liquid dosing head in and from the liquid dosing head support CAUTION Danger of injuries due to splashing liquids or substances! The bottle stands during use under 0.5 bar (7 psi) pressure. Liquid splashing out might harm the user and can damage the device. 1 Do not remove tubes under pressure. 2 Relieve pressure by switching off the insrument, pull out the tube. 1 Insert liquid dosing head in the liquid dosing head support. 2 To remove liquid dosing head from the liquid dosing head support, pull the catch (1) to the front and remove liquid dosing head (2). 12 Quantos Automated Dosing 3.4.1 Connecting the tubes Connectors of pump module Power Supply RS232C To Bottle CAN Inlet Pump CAN Exhaust The thinner tube is used for transporting liquid from the bottle to the liquid dosing head. The slightly bigger tube is used for pumping air into the bottle. By adding air, pressure rises in the bottle. When pressure reaches min. 0.3 to max 0.5 bar (4.4 to 7.2 psi) the micro dispensing valve in the dosing head opens and liquid can ascend the liquid tube. The two tubes are further referred to as liquid tube and air tube. § The liquid dosing head is inserted in the liquid dosing head 3 support. − Connect liquid tube (1) at bottle (2) and at liquid dosing head (3). Connect air tube NOTICE Damage on tube connectors because of mishandling! If the tubes are not removed correctly, the connectors and therefore the pump module can be damaged. Wrongly cut tubing can cause leaking connections. 1 To remove tubes, press down ring on connector and pull out tube carefully. 2 Cut tubes with a tube cutter. A tube in the air inlet to bottle (5) opens the valve of the air outlet. Never leave a tube which is connected to the air outlet unconnected at the other end because pressure can not be built up. You can connect up to 3 bottles to the pump module (7). Quantos Automated Dosing 13 − Connect the air tube (4) at the air inlet of the bottle (5) and the air outlet of the pump module (6). Remove air tube 1 Remove air tube to the bottle (4) by firmly press lay down the ring (8) at the air inlet (5). 2 Remove the air tubing of the bottle (8) and only if necessary of the pump module by pushing the ring (9). 9 6 Use the pump with protective gas WARNING Damage of pump because of high pressure! If you need to feed the pump with protective gas, e.g. nitrogen, make sure it does not exceed the pressure range of 0.2 bar (2.9 psi). The pump module might get damaged. 1 Ensure the protective gas does not exceed the pressure range of 0.2 bar (2.9 psi). 2 Wear protective glasses when working with the pump. 14 Quantos Automated Dosing 1 Insert muffler (10) into air inlet (11) to absorb noise. 2 If you need to feed the pump with protective gas, e.g. nitrogen, make sure it does not exceed the pressure range of 0.2 bar (2.9 psi). Wear protective glasses. Do not insert the muffler (11) but instead connect a tube to the air inlet (11). Note Outer tube diameter: 6 mm Pressure range: 0.1 to 0.2 bar (1.5 to 2.9 psi) 10 11 Contaminated air by using toxic, explosive or flammable liquids! WARNING Danger of injuries and death due to toxic substances! If you use toxic, explosive or flammable liquids, the exhaust air will be contaminated. − Use a tube for the exhaust air outlet. 1 If you use toxic, explosive or flammable liquids, the exhaust air will be contaminated and the device can get damaged. 2 Connect a tube to exhaust air (12) outlet to absorb the air into a safe container. Note Outer tube diameter: 6 mm 12 3.5 Installing liquid dosing head Installing liquid dosing head on liquid kit 1 Slide the liquid dosing head (1) onto the liquid kit (2) until it comes to a stop. 2 Press it down slightly until it is properly seated in the holding pins. Important Check that dosing head is inserted correctly. If there is just a small gap between dosing head and its support, press it down again. 3 Thread the liquid tube through slot in Quantos top glass. Quantos Automated Dosing 15 Removing liquid dosing head from liquid kit − To remove the liquid dosing head, press it slightly upwards and remove it to the front. 3.6 Connecting the tubes Connectors of pump module Power Supply To Bottle RS232C CAN Inlet Pump CAN Exhaust 1 WARNING Contaminated air! If you use toxic, explosive or flammable liquids, the exhaust air will be contaminated and the device can get damaged. Connect a tube to exhaust air outlet to absorb the air into a safe container. Note Outer tube diameter: 6 mm 12 CAUTION Damage on tube connectors because of mishandling! If the tubes are not removed correctly, the connectors and therefore the pump module can get damaged. − To remove tubes, press down ring on connector and pull out tube carefully. 16 Quantos Automated Dosing 3.7 Wiring the liquid module WARNING Danger of death or serious injury due to electric shock! Contact with parts that contain a live current can lead to injury and death. If the instrument cannot be shut down in an emergency situations, people can be injured or the instrument can be damaged. 1 To connect the pump module, only use the supplied three-core power cable with equipment grounding conductor. 2 Only connect the pump module to a three-pin power socket with earthing contact. 3 Only standardized extension cable with equipment grounding conductor must be used for operation of the pump module. 4 Do not disconnection the equipment grounding conductor. 5 Check that the voltage printed on it is the same as your local power supply voltage. ð If this is not the case, under no circumstances connect the AC adapter to the power supply, but contact a METTLER TOLEDO representative. Check the cables and the plug for damage and replace damaged cables and plugs. Make sure that the cables are arranged so that they cannot be damaged or interfere with the operation. Keep all electrical cables and connections away from liquids. Make sure that the power plug is accessible at all times. The balance is supplied with an AC/DC adapter and a country-specific power cable. The AC/DC adapter is suitable for use with the following voltage range: 100 – 240 V AC, 50/60 Hz. NOTICE • • • • • Check whether your local power supply falls within this range. If this is not the case, under no circumstances connect the AC/DC adapter to the power supply, but contact a METTLER TOLEDO representative. The power plug must be accessible at all times. Prior to use, check the power cable for damage. Route the cable in such a way that it cannot be damaged or cause a hindrance when working. Ensure that no liquid comes into contact with the AC/DC adapter. Important Wire the components before turning the balance on. After turning the balance on, if the message Wrong head type mounted appears, check wires. Make sure you connect CAN-cables before connecting power supplies. Quantos Automated Dosing 17 Connectors of pump module Power Supply RS232C To Bottle CAN Inlet Pump CAN Exhaust Note Power supply and RS232C Connector are covered with a faceplate. Remove faceplate. 1 Connect pump module with liquid kit via CAN-cable. There are 2 CAN-connectors on the pump module. There is no preference which one to take. 2 Remove left side glass and exchange one clip with the cable clip included in the scope of delivery. 3 Guide CAN-cable through cable clip and insert left side glass. 4 Connect pump module with balance via standard RS232Ccable. ð Liquid module is connected. 18 Quantos Automated Dosing 1 Connect power cable of liquid module to power socket and local power supply. 2 Connect power cable of balance to power socket and local power supply. Quantos Automated Dosing 19 4 Operation 4.1 Basic operation settings Refer to your XPE Operating Instructions for further information on settings and parameters. Navigation: [ ] > Liquid module... [Define] > Mounted... [Define] If you dose liquid for the first time, or after a master reset, check following settings: Configure your settings in the following menu: • • • • Dosing must be chosen as application: [ ] > [Dosing] Liquid module must be defined as mounted: [ ] > Liquid module… [Define] > [Mounted] Powder module must be defined as unmounted: [ ] > Powder module… [Define] > [Unmounted] RS232 device must be activated: [ ] > [System] > [Peripherals] > RFID / Quantos… [RS232 built-in] > [RS232 built-in] 4.2 Dosing liquid § Liquid dosing head is installed. § Weighing pan is empty. § If required, ErgoClip is installed. 1 Tap [Start] > [Liquid dosing]. 2 Enter User ID and confirm with [OK]. 3 Note The Sample ID is not mandatory and the instrument does not check whether or not it is unique. Enter Sample ID and confirm with [OK]. 4 Enter the amount Target liquid [g] required and confirm with [OK]. 5 Place sample vessel on weighing pan or ErgoClip and confirm with [OK]. 6 Lower position of dosing head until it is about 1 cm to 2 cm above the sample vessel and confirm with [OK]. 7 Note To abort dosing during process, tap [C]. Check, if all necessary adjustments are completed: To abort procedure, tap [No]. To start dosing, tap [Yes]. ð Pressure builds up. ð Instrument doses liquid. ð The results are being displayed. 8 To finish dosing process, confirm with [OK]. Congratulations, you have just successfully finished your first dosing! Note Bubbles in the tube do not impair the result, because the target result is weighed. If you dose liquids that might crystalize, clean the dosing head from time to time. Note See Quantos Liquid Module Operating Instructions for further information on your possibilities with the different dosing applications. • • 20 Quantos Automated Dosing 5 Technical Data 5.1 General data WARNING Danger of death or serious injury due to electric shock! Contact with parts that contain a live current can lead to injury and death. 1 Only use an approved AC adapter with a current-limited SELV output. 2 Ensure correct polarity Power supply AC adapter: Cable for AC adapter: Balance power supply: Primary: 100 – 240 V AC, -15%/+10%, 50/60 Hz Secondary: 12 V DC ±3%, 2.5 A (with electronic overload protection) 3-core, with country-specific plug 12 V DC ±3%, 2.5 A, maximum ripple: 80 mVpp Protection and standards Overvoltage category: Degree of pollution: Protection: Standards for safety and EMC: Range of application: II Protected against dust and water See Declaration of Conformity For use only in closed interior rooms Environmental conditions Height above mean sea level: Ambient temperature: Relative air humidity: Quantos Automated Dosing Up to 4000 m 5–40 °C Max. 80% up to 31 °C, linearly decreasing to 50% at 40 °C, noncondensing 21 22 Quantos Automated Dosing www.mt.com/quantos For more information Mettler-Toledo GmbH Im Langacher 44 8606 Greifensee, Switzerland www.mt.com/contact Subject to technical changes. © Mettler-Toledo GmbH 11/2016 30260315C en 30260315
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : Mettler-Toledo GmbH Create Date : 2016:11:28 07:04:04+01:00 Keywords : Quantos Automated Dosing, Liquid Module, 30260315 Modify Date : 2016:11:28 07:06:33+01:00 Subject : Liquid Module Language : en-US XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Format : application/pdf Creator : Mettler-Toledo GmbH Description : Liquid Module Title : Quantos Automated Dosing Creator Tool : SCHEMA ST4 Metadata Date : 2016:11:28 07:06:33+01:00 Producer : ST4 PDF Engine (Build 6.0.0.0) Document ID : uuid:c54f5b22-2411-44cc-aca4-59231d923d29 Instance ID : uuid:f4fbc349-c067-4ced-a790-8b6e48954620 Page Mode : UseOutlines Page Count : 24EXIF Metadata provided by EXIF.tools