Microelectronics Technology RU00-M03 RFID HP-SIP Module User Manual 43 RU00 M03 X001 01 A1
Microelectronics Technology Inc RFID HP-SIP Module 43 RU00 M03 X001 01 A1
Contents
- 1. User Manual.pdf
- 2. Users Manual_rev.pdf
- 3. Users Manual_rev 3.pdf
Users Manual_rev 3.pdf
Confidential Level(安全等級) □ Public(公開) █ Low(內部使用) NOTE: □ Medium(中度機密) APPROVAL ON THIS PAGE SIGNIFIES THE ENTIRE DOCUMENT APPROVED □ High(高度機密) RU00-M03 RFID High Power SiP Quick Guide A1 ECO- 10-19-2018 REV Change Order DATE Document No.: 43-RU00-M03-X001-01 Page No.: OF 18 江 東 曄 AS ISSUED CHANGE INFORMATION APPROVED BY AUTHOR 葉曜誠 Confidential Level(安全等級 安全等級):Low(內部使用) RU00-M03 RFID High Power SiP Quick Guide 43-RU00-M03-X001-01 PAGE: 2 DATE: 10-19-2018 REVISION HISTORY Document No.: 43-RU00-M03-X001-01 TITLE: RU00-M03 RFID High Power SiP Quick Guide Confidential Level(安全等級 安全等級):Low(內部使用) RU00-M03 RFID High Power SiP Quick Guide 43-RU00-M03-X001-01 PAGE: 3 DATE: 10-19-2018 Table of Contents RU00-M03 RFID High Power SiP Quick Guide ..................................................................................................... 1 1.0 2.0 Introduction ......................................................................................................................................... 4 Regulatory Statement .......................................................................................................................... 5 Federal Communication Commission Interference Statement ............................................................... 5 3.0 System Block Diagram ......................................................................................................................... 6 4.0 5.0 Pin Configurations and Descriptions................................................................................................... 8 Package Information ......................................................................................................................... 10 Package Mechanical Outline ................................................................................................................ 10 Recommend Footprint .......................................................................................................................... 11 Recommend Stencil ............................................................................................................................... 12 6.0 7.0 Interfacing to the RU00-M03............................................................................................................. 13 Operating the RU00-M03................................................................................................................... 15 8.0 Regulatory Guidelines ........................................................................................................................... 16 Figures Figure 1: System Block Diagram ........................................................................................................................ 7 Figure 2: Pin Configurations .............................................................................................................................. 8 Figure 3: Package Mechanical Outline ............................................................................................................ 10 Figure 4: Recommend Footprint ..................................................................................................................... 11 Figure 5: Recommend Stencil.......................................................................................................................... 12 Tables Table 1: Band configurations............................................................................................................................. 4 Table 2: Pin Configurations ............................................................................................................................... 9 Confidential Level(安全等級 安全等級):Low(內部使用) PAGE: 4 RU00-M03 RFID High Power SiP Quick Guide 43-RU00-M03-X001-01 1.0 DATE: 10-19-2018 Introduction The RU00-M03 is a System in Package (SiP) that comprises a completely in integrated solution for EPC Gen 2 / ISO18000-63 (formerly 18000-6C) application. The SiP was developed to make embedding UHF RFID reader capability easy. The RU00-M03 builds on market-leading Indy reader chip technology and integrates all of the necessary components into a tiny package. It requires very few external components. The RU00-M03 comes in a surface mount package designed to work as a SMT (surface mount technology) component in a standard PCB manufacturing process. This document provides instructions to the end-user to ensure optimal performance in their OEM hardware. Details on the use of the RU00-M03 Development Kit are also included to provide an example of appropriate application. Model Number RU00-M03-X001 RU00-M03-X011 Supported Regions Operating Frequency US 902.75MHz~927.25MHz EU 865.7MHz~867.5MHz CN 920.625MHz~924.375MHz JP 916.8MHz~920.4MHz Table 1: Band configurations Regions configuration in different end-use products is limited by an original equipment manufacturer (OEM) Confidential Level(安全等級 安全等級):Low(內部使用) PAGE: 5 RU00-M03 RFID High Power SiP Quick Guide 43-RU00-M03-X001-01 2.0 DATE: 10-19-2018 Regulatory Statement Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 21cm between the radiator & your body. Confidential Level(安全等級 安全等級):Low(內部使用) RU00-M03 RFID High Power SiP Quick Guide 43-RU00-M03-X001-01 3.0 PAGE: 6 DATE: 10-19-2018 System Block Diagram An example of a RU00-M03 system-level block diagram for an embedded application is shown in Figure 1. Required connections: VDC and GND are required to power the RU00-M03. RF pin must be connected to the OEM antenna. UART1 provides host communications to control the operation of the RU00-M03. ENABLE pin resets the RU00-M03 when set low. Recommended connections: UART2 provides debug information. HEALTH indicates successful boot of the RU00-M03. Connection to an LED provides a visual indication of whether or not an error condition exists. STATUS provides an indication when the RU00-M03 is inventorying tags. Connection to an LED provides a visual indicator of the tag activity. Optional connections: GPIO allow the user to provide general-purpose user-controlled digital I/O WAKEUP is a digital input which may wake the RU00-M03 from its sleep mode, the lowest power state of the RU00-M03 (TBD). Antenna port can be added by multiplexer (Switch). Confidential Level(安全等級 安全等級):Low(內部使用) RU00-M03 RFID High Power SiP Quick Guide 43-RU00-M03-X001-01 Figure 1: System Block Diagram PAGE: 7 DATE: 10-19-2018 Confidential Level(安全等級 安全等級):Low(內部使用) RU00-M03 RFID High Power SiP Quick Guide 43-RU00-M03-X001-01 4.0 PAGE: 8 DATE: 10-19-2018 Pin Configurations and Descriptions The module is 35-pin surface mount package (SMT compatible). The pin configurations are shown in Figure Figure 2: Pin Configurations Confidential Level(安全等級 安全等級):Low(內部使用) PAGE: 9 RU00-M03 RFID High Power SiP Quick Guide DATE: 10-19-2018 43-RU00-M03-X001-01 Pin Number 10 11 Pin Name VDC GND UART2_TX UART2_RX GND UART1_TX UART1_RX GND ENABLE GND VDC Type Description Power Ground Output Input Ground Output Input Ground Input Ground Power Power Supply Ground UART Debug Transmit Data UART Debug Receive Data Ground UART Console Transmit Data UART Console Receive Data Ground Active High Enable Device Ground Power Supply Ground Ground WAKEUP GPIO1 GPIO2 GPIO3 GPIO4 STATUS HEALTH GND CLK_OUT DTEST0 DTEST1 GND ANT2 GND ANT1 Input I/O I/O I/O I/O Output Output Ground Output Output Output Ground Output Ground Output Active High Wake up Device General Purpose Input/Output General Purpose Input/Output General Purpose Input/Output (*1) General Purpose Input/Output (*2) Status Indication Status Indication Ground N/A N/A N/A Ground Monostatic antenna port 2 (*3) Ground Monostatic antenna port 1 (*3) 32,33,34,35 GND Ground Ground UFL1 UFL2 ANT3 ANT4 Output Output Monostatic antenna port 3 (*3) Monostatic antenna port 4 (*3) 12,13,14,15,16 GND 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Table 2: Pin Configurations (*1) Pin 20: GPIO3 can be configured to SWDIO (Serial Wire Input/Output) for programming Confidential Level(安全等級 安全等級):Low(內部使用) PAGE: 10 RU00-M03 RFID High Power SiP Quick Guide 43-RU00-M03-X001-01 DATE: 10-19-2018 (*2) Pin 21: GPIO4 can be configured to SWDIO (Serial Wire Input/Output) for programming (*3) Antenna connections may be used via ANT1 (pin 31), ANT2 (pin 29) pads with 50Ω line on the bottom of board and via U.FL connectors on the top of board named ANT3(UFL1) and ANT4(UFL2). 5.0 Package Information Package Mechanical Outline Figure 3: Package Mechanical Outline Confidential Level(安全等級 安全等級):Low(內部使用) RU00-M03 RFID High Power SiP Quick Guide 43-RU00-M03-X001-01 Recommend Footprint Figure 4: Recommend Footprint PAGE: 11 DATE: 10-19-2018 Confidential Level(安全等級 安全等級):Low(內部使用) PAGE: 12 RU00-M03 RFID High Power SiP Quick Guide 43-RU00-M03-X001-01 DATE: 10-19-2018 Recommend Stencil Figure 5: Recommend Stencil Confidential Level(安全等級 安全等級):Low(內部使用) RU00-M03 RFID High Power SiP Quick Guide 43-RU00-M03-X001-01 6.0 PAGE: 13 DATE: 10-19-2018 Interfacing to the RU00-M03 Power and Ground All circuits on the RU00-M03 are powered from inputs at pin 1 and 11. The RU00-M03 operates with any supply voltage between 3.2 and 5.25V. Because the individual supplies within the part are regulated on the RU00-M03, a large amount of supply filtering is not required. A high value, low ESR tantalum capacitor (150uF or greater) is recommended and should be accompanied by a 0.1uF ceramic chip capacitor close to the pin. All 16 available ground pins of the RU00-M03 must be soldered to the user PCB per the recommended assembly guidelines. If the PCB utilizes separate analog/RF and digital grounds, it is recommended that the RU00-M03 connect to the analog/RF ground. Providing a highly conductive path from the SiP ground to a continuous ground plane (by use of numerous vias to the ground plane) and as much ground conductor area as possible on the outer layers of the user PCB will help to reduce the RU00-M03 temperature rise during operation. Communication The RU00-M03 has two UART ports, each of which utilizes 3.3V CMOS I/O over a pair of pins. The UARTs are compatible with a standard RS-232C serial port through an appropriate level translator IC. The user’s host processor issues IRI commands to the HOST UART (RX pin 7, TX pin 6), which can be configured for any standard UART data rate for 115.2k, 230.4k, 460.8k and 921.6 kbaud. The default rate is set to 115.2 kbaud. The DEBUG UART (RX pin 4, TX pin 3) is available to provide status information from the RU00-M03 microcontroller. The DEBUG UART is not required for RU00-M03 reader applications and should be operated at a fixed data rate of 115.2 kbaud. Please see the RU00-M03data sheet for detailed I/O specifications. RF The RU00-M03 is configured for monostatic operation, which requires only a single RF I/O pin for full duplex communication. The output must be routed to the antenna via 50 ohm microstrip or stripline on the OEM PCB. No coupling capacitor is required given that the RF pin is AC-coupled internal to the RU00-M03. To maximize the radiated power (and corresponding communication range), the length of the transmission line between RU00-M03 and antenna should be made as short as possible. GPIO Confidential Level(安全等級 安全等級):Low(內部使用) RU00-M03 RFID High Power SiP Quick Guide 43-RU00-M03-X001-01 PAGE: 14 DATE: 10-19-2018 There are four user-configurable digital GPIOs on the RU00-M03. The signals are number GPIO1 – GPIO4 and occupy pins 17 – 20 respectively. Each GPIO operates at standard 3.3V CMOS logic levels with a minimum output current capability of 4 mA per pin while maintaining guaranteed noise margins. Appropriate interface circuitry and layout as well as handling of the OEM hardware should be applied. Please see the RU00-M03 data sheet for detailed I/O specifications. Enable Pin 9 of the RU00-M03 comprises the ENABLE signal. The RU00-M03 is held in reset if the signal is held low. The ENABLE signal is bidirectional and is pulled down to 3.3V by ~10kΩ resistance internal to the RU00-M03. Any external connection to this pin must maintain a low impedance (<<10kΩ) other than when an external reset signal is applied. This allows the RU00-M03 to exert control of the reset line during power up and other situations that require it. Health and Status RU00-M03 pin 22 is a dedicated digital output that indicates the HEALTH of the RU00-M03. After the RU00-M03 is successfully booted and in its operational state, the health output switches to low. Otherwise, the output is high. The OEM can digitally monitor this signal or use it to drive an LED for visual indication of the RU00-M03 health. Pin 23 is a dedicated digital output that indicates the tag inventory STATUS of the RU00-M03. When the RU00-M03 is successfully inventorying one or more tags, it will generate 0.5ms minimum high pulse. The output remains low when no tags are being inventoried. Like the health signal, the OEM can monitor it via firmware or use it to drive an LED for visual indication to the device user. Confidential Level(安全等級 安全等級):Low(內部使用) RU00-M03 RFID High Power SiP Quick Guide 43-RU00-M03-X001-01 7.0 PAGE: 15 DATE: 10-19-2018 Operating the RU00-M03 Once the required hardware connections are made to the RU00-M03, the unit can be operated with simple software routines running on the OEM’s host processor. The host software issues commands to configure the reader, set the reader’s idle mode and to start and stop various Gen2 RFID reader operations. An example of the sequence of events starting at reader power-up is: 1. Apply 3.2V~5.25V power to the RU00-M03. 2. Establish a connection to the device via the host software. 3. Configure the reader. Critical parameters are: a. Region of operation When configured for a specific region, the RU00-M03 can operate only according to the air interface standards for that region. Key communication parameters are not adjustable by the user but are inherent in the RU00-M03 firmware. The FCC regional operation is the default for the device. NOTE: The OEM is strictly forbidden to operate the RU00-M03 in a regional mode other than that in which the device is located. Applicable agency certification must be obtained by the OEM for their product to operate in the region in which it is located. The modular certification of the RU00-M03 in the U.S. may only be utilized by OEM’s that follow all guidelines set forth in this document. b. RF output power The RU00-M03 output power must be set to a level between 10 and 30dBm. The default power is set to the reader’s maximum allowable of 30dBm. 4. Initiate an RFID operation. Gen2 RFID operations including Inventory, Read, Write, Lock and Kill are initiated with a command. 5. Set the RU00-M03 standby mode. When the RU00-M03 is not executing an RFID operation, it assumes a low power state until another RFID function is initiated by the host. Confidential Level(安全等級 安全等級):Low(內部使用) RU00-M03 RFID High Power SiP Quick Guide 43-RU00-M03-X001-01 PAGE: 16 DATE: 10-19-2018 8.0 Regulatory Guidelines OEM shall follow the below design guidelines for KDB 993369 1. Trace layout and dimensions including specific designs for each type: a. For the chain 2 and chain 3, it can be connected 50 ohm UFL mapping connector to external antenna b. For chain 0, it is connected via microstrip trace, please design guide as below. c. For chain 1 and chain 4, it is connected via microstrip trace and insert a single pole two through switch. The parameters in portion of transmission line are same as chain 0. The RF Switch is also 50 ohm characteristic and isolation is at least 20dB. It is equivalent to passive part. It always transmits one path at one time during operating. Confidential Level(安全等級 安全等級):Low(內部使用) RU00-M03 RFID High Power SiP Quick Guide 43-RU00-M03-X001-01 PAGE: 17 DATE: 10-19-2018 The RU00-M03 is designed for 50 +/- 10% Ohm characteristic impedance, and the connection between RU00-M03 and antenna should all be designed for 50 Ohm characteristic impedance. For connection to external antenna via connectors, user should design the PCB layout for 50 Ohm characteristic impedance using microstrip, stripline, etc. For example, user can design Microstrip according to PCB stack up (shown in below figure) by tool TXLINE (Transmission Line Calculator) to get PCB path width for RF is 7.5mil. The detail parameters such as operating center frequency, RF impedance, dialectical constant, trace width, height of PCB Copper thickness. Please see the below figure. 2. Appropriate parts by manufacturer and specifications. All parts from RF I/O interface of module to antenna shall meet characteristic impedance of 50 ohms +/10%. a. The connector on OEM’s PCB with interfaces to antenna must be 50ohm characteristic impedance Confidential Level(安全等級 安全等級):Low(內部使用) RU00-M03 RFID High Power SiP Quick Guide 43-RU00-M03-X001-01 PAGE: 18 DATE: 10-19-2018 as well. The following connectors are allowed. - Ultra UMCC Jack : Hirose electric, model U.FL-R-SMT-1 or equivalent - SMA Jack : Aliner Industries, model 20-001DW-T or equivalent. - Other 50ohm characteristic impedance equivalent RF connector b. It supports to add multiplexer (RF Switch) between transmission line and connector on OEM’s PCB. - RF switch: Skyworks, model SKY13270-92LF or equivalent. c. The cable between qualified antenna and connector shall use 50 ohm coaxial pigtail from connector of PCB to antenna. d. The OEM must strictly use only with the following antennas or antenna types with maximum gain as shown. - American RFID solution, model HD-500 circular polarization antenna with 6dBi gain - Microelectronics Technology Inc, model RFID0900 circular polarization antenna with 6dBi gain - BroadRadio, model BRA-07 circular polarization antenna with 3dBiC 3. Test procedures for design verification. -OEM shall follow transmission line design rule for characteristic impedance of 50 ohms +/- 10%. -OEM needs to measure transmission line width on PCB to ensure the impedance is 50 ohms +/- 10% 4. Production test procedures for ensuring compliance The 50 ohm transmission line and connector are passive parts, it is an attenuation in system. Once OEM has confirmed the impedance in design verification, OEM can measure output power via connector instead of transmission impedance measurement. -Connect cable with connector on OEM’s PCB to RF power meter or equivalent. -Execute OEM’s product to transmit output power and measure output power.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Page Count : 18 Producer : GPL Ghostscript 9.06 Create Date : 2018:10:19 09:59:40+08:00 Modify Date : 2018:10:19 09:59:40+08:00 Title : Microsoft Word - 43-RU00-M03-X001-01_A1 Creator : PScript5.dll Version 5.2.2 Author : 4697EXIF Metadata provided by EXIF.tools