Microlife BP3GT1-6B Upper Arm Automatic Digital Blood Pressure Monitor User Manual GT1 6B Master IB
Microlife Corporation Upper Arm Automatic Digital Blood Pressure Monitor GT1 6B Master IB
user manual
Microlife BP3GT1‐6B Instruction Manual v01 Model # BP3GT1‐6B Microlife BP3GT1‐6B Instruction Manual v01 Microlife BP3GT1‐6B Instruction Manual v01 Microlife BP3GT1‐6B Instruction Manual v01 Microlife BP3GT1‐6B Instruction Manual v01 Microlife BP3GT1‐6B Instruction Manual v01 Microlife BP3GT1‐6B Instruction Manual v01 Microlife BP3GT1‐6B Instruction Manual v01 Microlife BP3GT1‐6B Instruction Manual v01 Microlife BP3GT1‐6B Instruction Manual v01 10 Microlife BP3GT1‐6B Instruction Manual v01 11 Microlife BP3GT1‐6B Instruction Manual v01 12 Microlife BP3GT1‐6B Instruction Manual v01 13 Microlife BP3GT1‐6B Instruction Manual v01 14 Microlife BP3GT1‐6B Instruction Manual v01 15 Microlife BP3GT1‐6B Instruction Manual v01 16 Microlife BP3GT1‐6B Instruction Manual v01 17 Microlife BP3GT1‐6B Instruction Manual v01 18 Microlife BP3GT1‐6B Instruction Manual v01 19 Microlife BP3GT1‐6B Instruction Manual v01 20 Microlife BP3GT1‐6B Instruction Manual v01 21 Microlife BP3GT1‐6B Instruction Manual v01 22 Microlife BP3GT1‐6B Instruction Manual v01 23 Microlife BP3GT1‐6B Instruction Manual v01 24 Microlife BP3GT1‐6B Instruction Manual v01 25 Microlife BP3GT1-6B Instruction Manual an experienced radio/TV technician for help. v01 or consult the dealer or For body worn operation, this device has been tested and meets FCC RF exposure guidelines. When used with an accessory that contains metal may not ensure compliance with FCC RF exposure guidelines. 26 Microlife BP3GT1-6B Instruction Manual v01 1. Weight:326 g(with batteries) 2. Size:82x160x35 mm 3. Storage/ transportation Condition: Temperature: -20℃ ~ +55℃ (Humidity: 15% - 90% RH; non-condensed) 4. Operation Condition: Temperature: 10℃ ~ 40℃ (Humidity: 15% ~ 90% RH; non-condensed) 5. Display: LCD-Display(Liquid Crystal Display) 6. Measuring method: Oscillometric 7. Pressure sensor: Capacitive 8. Measuring range: Pressure (SYS/DIA): 20 to 280 mmHg Pulse: 40 to 200 beats/per min 9. Cuff pressure display range:0-299 mmHg 10. Memory: Automatically stores the last 120 measurements for 2 users(total 240) 11. Measuring resolution: 1 mmHg 12. Accuracy: Pressure within ± 3 mmHg; Pulse ± 5% of the reading 13. Power source: a) 4 AAA batteries, 1.5 V ; b) Certificated AC adapter 6 V DC 600 mA(voltage 4.5 V DC to 6 V DC) 14. Accessories: Wide range cuff for arm circumference 22-46 cm (8.7”-18.1”) Cradle Storage case 15. Adaptor Vendor: Deevan 16. Adaptor model: DSA-6E-05 17. atmospheric pressure:(80-105)KPa Operating instructions 1) comfortably seated 2) legs uncrossed 3) feet flat on the floor 4) back and arm supported 5) middle of the CUFF at the level of the right atrium of the heart 27 Microlife BP3GT1‐6B Instruction Manual v01 28 Microlife BP3GT1-6B Ins Manual v01 safety warning: 1. To avoid accidental strangulation, keep this product away from children and baby. 2. If this equipment is modified, appropriate inspection and testing must be conducted to ensure continued safe use of equipment 3. Only use accessories provided with the equipment. Otherwise erroneous results will be recorded. 4. regarding the effect of blood flow interference and resulting harmful injury to the PATIENT caused by continuous CUFF pressure due to connection tubing kinking; 5. indicating that too frequent measurements can cause injury to the PATIENT due to blood flow interference; 6. regarding the application of the CUFF over a wound, as this can cause further injury; 7. regarding the application of the CUFF and its pressurization on any limb where intravascular access or therapy, or an arterio-venous (A-V) shunt, is present because of temporary interference to blood flow and could result in injury to the PATIENT; 8. regarding the application of the CUFF and its pressurization on the arm on the side of a mastectomy; 9. regarding the information that pressurization of the CUFF can temporarily cause loss of function of simultaneously used monitoring ME EQUIPMENT on the same limb; 10.regarding the need to check (for example, by observation of the limb concerned) that operation of the AUTOMATED SPHYGMOMANOMETER does not result in prolonged impairment of the circulation of the blood of the PATIENT. 29 Guidance and manufacturer’s declaration-electromagnetic emissions The BP3GT1-6B is intended for use in the electromagnetic environment specified below. The customer or the user of the BP3GT1-6B should assure that it is used in such an environment. Emission test Compliance Electromagnetic environment-guidance RF emissions CISPR 11 Group 1 The BP3GT1-6B uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment. RF emissions CISPR 11 Class B Harmonic emissions IEC 61000-3-2 Class A Voltage fluctuations /flicker emissions IEC 61000-3-3 Compliance The BP3GT1-6B is suitable for use in all establishments, including domestic establishments and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes. Guidance and manufacturer’s declaration-electromagnetic immunity The BP3GT1-6B is intended for use in the electromagnetic environment specified below. The customer or the user of the BP3GT1-6B should assure that it is used in such an environment. Immunity test IEC 60601 Compliance level test level Electromagnetic environment-guidance Electrostatic + 6 kV contact + 6 kV contact Floors should be wood, concrete discharge(ESD) IEC + 8 kV air + 8 kV air or ceramic tile. If floors are 61000-4-2 covered with synthetic material, the relative humidity should be at least 30% Electrical fast + 2kV for power + 2kV for power Mains power quality should be transient/burst IEC supply lines supply lines that of a typical commercial or 61000-4-4 + 1kV for input/output Not applicable hospital environment. + 1kV line(s) to line(s) + 1kV differential Mains power quality should be + 2kV line(s) to earth mode that of a typical commercial or Not applicable hospital environment. lines Surge IEC 61000-4-5 Voltage Dips, short <5% UT(>95% dip in <5% UT(>95% dip in Mains power quality should be interruptions and voltage UT) for 0,5 cycle UT) for 0,5 cycle that of a typical commercial or variations on power supply 40% UT(60% dip in 40% UT(60% dip in hospital environment. If the user input lines IEC 61000-4-11 UT) for 5 cycles UT) for 5 cycles of the BP3GT1-6B 70% UT(30% dip in 70% UT(30% dip in requires continued operation UT) for 25 cycles UT) for 25 cycles during power mains <5% UT(>95% dip in <5% UT(>95% dip in interruptions, it is recommended UT) for 5 s UT) for 5 s that the BP3GT1-6B be powered from an uninterruptible power supply or a battery. Power frequency(50, 60 3 A/m 3 A/m The BP3GT1-6B power Hz) magnetic field IEC frequency magnetic fields 61000-4-8 should be at levels characteristic of a typical location in a typical commercial or hospital environment. NOTE UT is the a.c. mains voltage prior to application of the test level. Guidance and manufacturer’s declaration-electromagnetic immunity The BP3GT1-6B is intended for use in the electromagnetic environment specified below. The customer or the user of the BP3GT1-6B should assure that is used in such and environment. Immunity test IEC 60601 test level Compliance level Electromagnetic environment-guidance Portable and mobile RF communications equipment should be used no closer to any part of the BP3GT1-6B including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Recommended separation distance: Conducted RF 3 Vrms IEC 61000-4-6 150 KHz to 80 MHz Radiated RF 3 V/m IEC 61000-4-3 80MHz to 2,5 GHz 3 Vrms 3 V/m d = 1,2 √P d = 1,2 √P 80MHz to 800 MHz d = 2,3 √P 800MHz to 2,5 GHz Where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in metres (m). Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey, should be less than the compliance level in each frequency range. Interference may occur in the vicinity of equipment marked with the following symbol: NOTE1 At 80 MHz and 800 MHz, the higher frequency range applies. NOTE2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the BP3GT1-6B is used exceeds the applicable RF compliance level above, the BP3GT1-6B should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the BP3GT1-6B. Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m. Recommended separation distance between portable and mobile RF communications equipment and the BP3GT1-6B The BP3GT1-6B is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the BP3GT1-6B can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the BP3GT1-6B as recommended below, according to the maximum output power of the communications equipment. Rated maximum output Separation distance according to frequency of transmitter power of transmitter 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2,5 GHz d =1,2√P d =1,2√P d =2,3√P 0,01 0,12 0,12 0,23 0,1 0,38 0,38 0,73 1,2 1,2 2,3 10 3,8 3,8 7,3 100 12 12 23 For transmitters rated at a maximum output power not listed above, the recommended separation distance d in metres (m) can be estimated using the equation applicable to the frequency of the transmitter, where p is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. NOTE1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. NOTE2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : ida.chen Create Date : 2017:01:20 17:37:17+08:00 Modify Date : 2017:02:22 15:57:21+08:00 XMP Toolkit : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27 Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2017:02:22 15:57:21+08:00 Thumbnail Width : 184 Thumbnail Height : 256 Thumbnail Format : JPEG Thumbnail Image : (Binary data 9545 bytes, use -b option to extract) Producer : Acrobat Distiller 9.0.0 (Windows) Trapped : False Format : application/pdf Title : Microsoft Word - GT1-6B Master IB Creator : ida.chen Document ID : uuid:34763542-9c3c-41a3-aecb-01dd00fe364d Instance ID : uuid:8baf1cdb-9f41-1f44-83b5-d6e6293b2b37 Rendition Class : proof:pdf Version ID : 1 N Pages : 1 Has Visible Transparency : False Has Visible Overprint : False Max Page Size W : 209.980292 Max Page Size H : 297.038889 Max Page Size Unit : Millimeters Font Name : Calibri, AdobeSongStd-Light Font Family : Calibri, Adobe 宋体 Std Font Face : Regular, L Font Type : Open Type, Open Type Font Version : Version 5.62, Version 5.016;PS 5.002;hotconv 1.0.67;makeotf.lib2.5.33168 Font Composite : False, False Font File Name : Calibri.ttf, AdobeSongStd-Light.otf Plate Names : Black Swatch Groups Group Name : Default Swatch Group Swatch Groups Group Type : 0 GTS PDFX Version : PDF/X-4 Page Count : 33EXIF Metadata provided by EXIF.tools