Dark Field Series Illuminator Configuration Guide Darkfieldconfigguide

2011-08-08

: Microscan Darkfieldconfigguide darkfieldconfigguide 13b8e8d0-adb7-4ac6-9c89-4f5a1681a888 _att

Open the PDF directly: View PDF PDF.
Page Count: 2

DownloadDark Field Series Illuminator Configuration Guide  Darkfieldconfigguide
Open PDF In BrowserView PDF
Nerlite

Dark Field Light Series Illuminators

Configuration Guide
		

Strobe Current	

Continuous Operation	

						
Part			
Ring 1 (& 2 			
Number	
Description	
Continuous Current	
Where Applicable)	
Ring 3	
Fan Cooled	
NER-011609311	

DF-50 Red Continuous, Non-Diffuse	

NER-011609312	

DF-50 Red Strobe, Non-Diffuse	

NER-011609321	

DF-50 White Continuous, Non-Diffuse	

NER-011609322	

DF-50 White Strobe, Non-Diffuse	

NER-011609331	

DF-50 Blue Continuous, Non-Diffuse	

NER-011609332	

DF-50 Blue Strobe, Non-Diffuse	

NER-011601520	

DF-100-1 Red Continuous, Non-Diffuse	

NER-011601521	

DF-100-1 Red Continuous, Diffuse	

69mA	

NA	

NA	

1.20A	

120mA	

NA	

NA	

2.40A	

Figure A	

Figure B		

1

100mA	

NA	

NA		

Figure A	

Figure B		

1

NER-011600031	

DF-150-1 White Continuous, Non-Diffuse	

NER-011600032	

DF-150-1 White Strobe, Non-Diffuse	

NER-011600070	

DF-150-1 Blue Continuous, Non-Diffuse	

196mA	

NA	

NER-011600080	

DF-150-1 Blue Strobe, Non-Diffuse	

NA	

4.00A	

NER-011600021	

DF-150-1 Red Continuous, Diffuse	

100mA	

NA	

NER-011600007	

DF-150-1 Red Strobe, Diffuse	

NA	

2.00A	

NER-011600041	

DF-150-1 White Continuous, Diffuse	

NER-011600042	

DF-150-1 White Strobe, Diffuse	

NER-011600208	

DF-150-3 Red Continuous, Non-Diffuse	

NER-011603300	

DF-200-1 Red Continuous, Diffuse	

NER-011603301	

DF-200-1 Red Strobe, Diffuse	

NA	

2.00A	
NA	

NA	

2.00A	

196mA	

NA	

NA	

4.00A	

196mA	

NA	

NA	

4.00A	

300mA	

NA	

NA	

7.14A	

450mA	

NA	

NA	

8.00A	

200mA	

NA	

NA	

4.00A	

Figure A	

Figure B		

1
1

NA		

100mA	

NA		

Figure B	

NA	

DF-150-1 Red Strobe, Non-Diffuse	

DF-150-3 White Strobe, Non-Diffuse	

NA				

1
1

NA	

NER-011600004	

DF-150-3 Red Strobe, Non-Diffuse	

Figure B	

Figure B		

2.40A	

DF-100-1 Red Strobe, Diffuse	

DF-150-3 White Continuous, Non-Diffuse	

Figure B		

Figure A	

NA	

DF-150-1 Red Continuous, Non-Diffuse	

NER-011600207	

NA		

100mA	

NER-011601502	

NER-011600209	

Figure A	

NA				

Connection Notes Reference Number
(See the Connection
Notes on back of the Page)

120mA	

NER-011600020	

NER-011600206	

NA		

Strobe Operation

No Controller Required	
NL-2XX Optional		
(Can be Connected	
(Used only if Intensity And/Or Ethernet		
Directly to 24VDC)	
Control Is Desired)	
NL-2XX (Required)	

NA				

Figure B	

NA				
NA		

Figure A	

Figure B	

Figure B		

NA				
NA		

Figure A	

Figure B	

Figure B		

NA				
NA		

Figure A	

Figure B	

Figure B		

NA				
NA		

Figure A	

Figure B	

Figure B		

NA				
NA		

Figure A	

Figure B	

Figure B		

NA				
NA		

Figure A	

Figure B	

Figure B		

NA				
NA		

Figure A	

Figure B	

Figure B		

4.00A				
NA		

Figure A	

Figure B	

Figure B		

NA				

Figure B	

1
1

1
1
1
1
1
1
1
1
1
1
1
1
1
1
6
1
1

Hardware Required
	 Item	
	
1	
	
2	
	
3	

Description	
DF Series Illuminators	
Power Supply DSP60 24VDC 2.5A DIN Mount	
NL-200 Current Controller Series	

Part Number
NER-01160XXXX
NER-011504100
98-000152-0X

1

3

Copyright ©2010 Microscan Systems, Inc.	

- POWER
+ INPUT

Figure A
Dark Field Series Illuminator
with power supply

2

- 12V. 1.4A (UNFUSED)
+ POWER OUTPUT

2

1

Figure B
Dark Field Series Illuminator
with NL-200 and power supply

P/N 83-230003 Rev B

NERLITE Dark Field Light Series Illuminators

Accessories
AC Power Cord US	
AC Power Cord EU	
AC Power Cord UK	

NER-030028300	
NER-030028400	
NER-030028500	

Power Cord For Power Supply
Power Cord For Power Supply
Power Cord For Power Supply

General Notes:
1.	Those lights that do not require a controller require 24VDC +/- 1%.
2.	The NL-2XX series controllers require 24 to 48VDC.
3.	The cable on all flying lead models is terminated with three, five, or seven leads. Each lead is labeled. See “Connection Notes” for connection instructions.
4.	For all models with M12 connectors, the connector is a 4 pin, male, M12 connector. See “Connection Notes” or connector pin out and connection instructions.
5.	All models with separate fan circuits must have 24VDC connected to the fan circuit at all times when the light is operating.
6.	When operating in strobe mode at the maximum rated current, the maximum pulse width = 1mS and the maximum duty cycle = 6%. See the NL-2XX series controllers’
manual for pulse width and duty cycle limitations under various conditions.
7. ATTENTION! When programming an NL-2XX series controller for use in strobe mode, you must set the current rating to 10% of the current specified in this configuration
guide. In the few cases where an individual light that requires both channels of the NL-200, be sure to set the current for each channel as specified in this configuration
guided. Note: The currents for channel 1 and channel 2 are not always the same. The NL-2XX Series Controller allows the operator to set the output to 1000% of the rated
current in strobe mode. By programming the initial current rating at 10% of the light’s rated current, full intensity is achieved and the controller is prevented from exceeding
the light’s rated current. Setting the current rating at a value greater than 10% of the current printed on the configuration label on the light may result in damage to the light.
Connection Notes:
1.	Connect the lead labeled “V+” to the positive(+) output terminal of the power supply or controller. Connect the lead labeled “GND” to the negative(-) output terminal of the
power supply or controller. Connect the lead labeled “Shield” or “SHLD” to chassis ground.
2.	Connect the lead labeled “V+” to the positive(+) output terminal of the power supply or controller. Connect the lead labeled “GND” to the negative(-) output terminal of the
power supply or controller. Connect the lead labeled “Fan V+” to the positive(+) output terminal of a 24VDC power supply. Connect the lead labeled “Fan GND” to the negative(-) output terminal of a 24VDC power supply. Connect the lead labeled “Shield” to chassis ground.
3. Connect the lead labeled “V+1” to the positive(+) output terminal of channel 1 on an NL-2XX series controller. Connect the lead labeled “GND1” to the negative(-) output
terminal of channel 1 on the NL-2XX series controller. Connect the lead labeled “V+2” to the positive(+) outpt terminal of channel 2 on the NL-2XX series controller. Connect
the lead labeled “GND2” to the negative(-) output terminal of channel 2 on the NL-2XX series controller. Connect the lead labeled “Shield” to chassis ground
4.	Connect the lead labeled “+” to the positive(+) output terminal of the power supply or controller. Connect the lead labeled “-” to the negative(-) output terminal of the power
supply or controller. Connect the cable’s braided shield to chassis ground.
5.	Connect the lead labeled “DOAL V+” to the positive(+) output terminal of channel 1 on an NL-2XX series controller. Connect the lead labeled “DOAL GND” to the negative(-) output terminal of channel 1 on the NL-2XX series controller. Connect the lead labeled “Ring V+” to the positive(+) output terminal of channel 2 on the NL-2XX series
controller. Connect the lead labeled “Ring GND” to the negative(-) output terminal of channel 2 on the NL-2XX series controller. Connect the lead labeled “Fan V+” to the
positive(+) output terminal of a 24VDC power supply. Connect the lead labeled “Fan GND” to the negative(-) output terminal of a 24VDC power supply. Connect the lead
labeled “Shield” to chassis ground.
6.	Connect the two leads labeled “RING 1, 2 V+” & “RING 3 V+” to the same positive(+) output terminal of the power supply or controller. Connect the two leads labeled “RING
1, 2 -” & “RING 3 -” to the same negative(-) output terminal of the power supply or controller. Connect the lead labeled “Shield” to chassis ground.
7.	Connect Pin 1 of the M12-M connector to the positive(+) output terminal of the power supply or controller. Connect Pin 3 of the M12-M connector to the negative(-) output
terminal of the power supply or controller. Connect the shell of the M12-M connector to chassis ground. Pins 2 and 4 are not used.

Copyright ©2010 Microscan Systems, Inc.	

www.microscan.com



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Create Date                     : 2010:04:19 17:11:30-04:00
Metadata Date                   : 2011:08:08 12:43:22-07:00
Modify Date                     : 2011:08:08 12:43:22-07:00
Creator Tool                    : Adobe InDesign CS3 (5.0.4)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 10185 bytes, use -b option to extract)
Instance ID                     : uuid:9dd6df46-ac65-4be9-baad-0ff9f6f99b59
Original Document ID            : xmp.did:D5800130202611688507D49043955069
Document ID                     : adobe:docid:indd:7ada5aeb-073b-11df-a7de-be08506ea2fc
Rendition Class                 : proof:pdf
History Action                  : created, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved
History Instance ID             : xmp.iid:D5800130202611688507D49043955069, xmp.iid:E178A97C219A11688507D49043955069, xmp.iid:E178A97D219A11688507D49043955069, xmp.iid:E178A97F219A11688507D49043955069, xmp.iid:E178A980219A11688507D49043955069, xmp.iid:E178A981219A11688507D49043955069, xmp.iid:1563EC8321A611688507D49043955069, xmp.iid:1563EC8421A611688507D49043955069, xmp.iid:1563EC8621A611688507D49043955069, xmp.iid:1563EC8721A611688507D49043955069, xmp.iid:1563EC8821A611688507D49043955069, xmp.iid:531F6F3121AF11688507D49043955069
History When                    : 2010:01:15 10:51:27-05:00, 2010:01:15 10:54:44-05:00, 2010:01:15 10:54:44-05:00, 2010:01:15 11:06:40-05:00, 2010:01:15 11:06:40-05:00, 2010:01:15 11:57:08-05:00, 2010:01:15 12:17:40-05:00, 2010:01:15 12:17:40-05:00, 2010:01:15 12:39:26-05:00, 2010:01:15 12:41:09-05:00, 2010:01:15 12:49:28-05:00, 2010:01:15 13:39:16-05:00
History Software Agent          : Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0
History Changed                 : /, /metadata, /metadata, /;/metadata, /, /metadata, /;/metadata, /, /, /, /
Derived From Instance ID        : xmp.iid:1563EC8321A611688507D49043955069
Derived From Document ID        : xmp.did:E178A980219A11688507D49043955069
Derived From Original Document ID: xmp.did:D5800130202611688507D49043955069
Derived From Rendition Class    : default
Manifest Link Form              : ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 150.00, 300.00
Manifest Placed Y Resolution    : 150.00, 300.00
Manifest Placed Resolution Unit : Inches, Inches
Manifest Reference Instance ID  : uuid:229C1150196D11DF960CEC6F3FC6B53E, xmp.iid:59F2D171B8B9DE119EF6AD6A4AAF49EF
Manifest Reference Document ID  : uuid:95E657032FEFDE11AD1AA48928C286E9, xmp.did:58F2D171B8B9DE119EF6AD6A4AAF49EF
Doc Change Count                : 888
Format                          : application/pdf
Title                           : Dark Field Series Illuminator Configuration Guide
Creator                         : 
Producer                        : Adobe PDF Library 8.0
Trapped                         : False
Page Count                      : 2
Page Layout                     : SinglePage
Warning                         : [Minor] Ignored duplicate Info dictionary
EXIF Metadata provided by EXIF.tools

Navigation menu