Dark Field Series Illuminator Configuration Guide Darkfieldconfigguide
2011-08-08
: Microscan Darkfieldconfigguide darkfieldconfigguide 13b8e8d0-adb7-4ac6-9c89-4f5a1681a888 _att
Open the PDF directly: View PDF
.
Page Count: 2
| Download | |
| Open PDF In Browser | View PDF |
Nerlite Dark Field Light Series Illuminators Configuration Guide Strobe Current Continuous Operation Part Ring 1 (& 2 Number Description Continuous Current Where Applicable) Ring 3 Fan Cooled NER-011609311 DF-50 Red Continuous, Non-Diffuse NER-011609312 DF-50 Red Strobe, Non-Diffuse NER-011609321 DF-50 White Continuous, Non-Diffuse NER-011609322 DF-50 White Strobe, Non-Diffuse NER-011609331 DF-50 Blue Continuous, Non-Diffuse NER-011609332 DF-50 Blue Strobe, Non-Diffuse NER-011601520 DF-100-1 Red Continuous, Non-Diffuse NER-011601521 DF-100-1 Red Continuous, Diffuse 69mA NA NA 1.20A 120mA NA NA 2.40A Figure A Figure B 1 100mA NA NA Figure A Figure B 1 NER-011600031 DF-150-1 White Continuous, Non-Diffuse NER-011600032 DF-150-1 White Strobe, Non-Diffuse NER-011600070 DF-150-1 Blue Continuous, Non-Diffuse 196mA NA NER-011600080 DF-150-1 Blue Strobe, Non-Diffuse NA 4.00A NER-011600021 DF-150-1 Red Continuous, Diffuse 100mA NA NER-011600007 DF-150-1 Red Strobe, Diffuse NA 2.00A NER-011600041 DF-150-1 White Continuous, Diffuse NER-011600042 DF-150-1 White Strobe, Diffuse NER-011600208 DF-150-3 Red Continuous, Non-Diffuse NER-011603300 DF-200-1 Red Continuous, Diffuse NER-011603301 DF-200-1 Red Strobe, Diffuse NA 2.00A NA NA 2.00A 196mA NA NA 4.00A 196mA NA NA 4.00A 300mA NA NA 7.14A 450mA NA NA 8.00A 200mA NA NA 4.00A Figure A Figure B 1 1 NA 100mA NA Figure B NA DF-150-1 Red Strobe, Non-Diffuse DF-150-3 White Strobe, Non-Diffuse NA 1 1 NA NER-011600004 DF-150-3 Red Strobe, Non-Diffuse Figure B Figure B 2.40A DF-100-1 Red Strobe, Diffuse DF-150-3 White Continuous, Non-Diffuse Figure B Figure A NA DF-150-1 Red Continuous, Non-Diffuse NER-011600207 NA 100mA NER-011601502 NER-011600209 Figure A NA Connection Notes Reference Number (See the Connection Notes on back of the Page) 120mA NER-011600020 NER-011600206 NA Strobe Operation No Controller Required NL-2XX Optional (Can be Connected (Used only if Intensity And/Or Ethernet Directly to 24VDC) Control Is Desired) NL-2XX (Required) NA Figure B NA NA Figure A Figure B Figure B NA NA Figure A Figure B Figure B NA NA Figure A Figure B Figure B NA NA Figure A Figure B Figure B NA NA Figure A Figure B Figure B NA NA Figure A Figure B Figure B NA NA Figure A Figure B Figure B 4.00A NA Figure A Figure B Figure B NA Figure B 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 6 1 1 Hardware Required Item 1 2 3 Description DF Series Illuminators Power Supply DSP60 24VDC 2.5A DIN Mount NL-200 Current Controller Series Part Number NER-01160XXXX NER-011504100 98-000152-0X 1 3 Copyright ©2010 Microscan Systems, Inc. - POWER + INPUT Figure A Dark Field Series Illuminator with power supply 2 - 12V. 1.4A (UNFUSED) + POWER OUTPUT 2 1 Figure B Dark Field Series Illuminator with NL-200 and power supply P/N 83-230003 Rev B NERLITE Dark Field Light Series Illuminators Accessories AC Power Cord US AC Power Cord EU AC Power Cord UK NER-030028300 NER-030028400 NER-030028500 Power Cord For Power Supply Power Cord For Power Supply Power Cord For Power Supply General Notes: 1. Those lights that do not require a controller require 24VDC +/- 1%. 2. The NL-2XX series controllers require 24 to 48VDC. 3. The cable on all flying lead models is terminated with three, five, or seven leads. Each lead is labeled. See “Connection Notes” for connection instructions. 4. For all models with M12 connectors, the connector is a 4 pin, male, M12 connector. See “Connection Notes” or connector pin out and connection instructions. 5. All models with separate fan circuits must have 24VDC connected to the fan circuit at all times when the light is operating. 6. When operating in strobe mode at the maximum rated current, the maximum pulse width = 1mS and the maximum duty cycle = 6%. See the NL-2XX series controllers’ manual for pulse width and duty cycle limitations under various conditions. 7. ATTENTION! When programming an NL-2XX series controller for use in strobe mode, you must set the current rating to 10% of the current specified in this configuration guide. In the few cases where an individual light that requires both channels of the NL-200, be sure to set the current for each channel as specified in this configuration guided. Note: The currents for channel 1 and channel 2 are not always the same. The NL-2XX Series Controller allows the operator to set the output to 1000% of the rated current in strobe mode. By programming the initial current rating at 10% of the light’s rated current, full intensity is achieved and the controller is prevented from exceeding the light’s rated current. Setting the current rating at a value greater than 10% of the current printed on the configuration label on the light may result in damage to the light. Connection Notes: 1. Connect the lead labeled “V+” to the positive(+) output terminal of the power supply or controller. Connect the lead labeled “GND” to the negative(-) output terminal of the power supply or controller. Connect the lead labeled “Shield” or “SHLD” to chassis ground. 2. Connect the lead labeled “V+” to the positive(+) output terminal of the power supply or controller. Connect the lead labeled “GND” to the negative(-) output terminal of the power supply or controller. Connect the lead labeled “Fan V+” to the positive(+) output terminal of a 24VDC power supply. Connect the lead labeled “Fan GND” to the negative(-) output terminal of a 24VDC power supply. Connect the lead labeled “Shield” to chassis ground. 3. Connect the lead labeled “V+1” to the positive(+) output terminal of channel 1 on an NL-2XX series controller. Connect the lead labeled “GND1” to the negative(-) output terminal of channel 1 on the NL-2XX series controller. Connect the lead labeled “V+2” to the positive(+) outpt terminal of channel 2 on the NL-2XX series controller. Connect the lead labeled “GND2” to the negative(-) output terminal of channel 2 on the NL-2XX series controller. Connect the lead labeled “Shield” to chassis ground 4. Connect the lead labeled “+” to the positive(+) output terminal of the power supply or controller. Connect the lead labeled “-” to the negative(-) output terminal of the power supply or controller. Connect the cable’s braided shield to chassis ground. 5. Connect the lead labeled “DOAL V+” to the positive(+) output terminal of channel 1 on an NL-2XX series controller. Connect the lead labeled “DOAL GND” to the negative(-) output terminal of channel 1 on the NL-2XX series controller. Connect the lead labeled “Ring V+” to the positive(+) output terminal of channel 2 on the NL-2XX series controller. Connect the lead labeled “Ring GND” to the negative(-) output terminal of channel 2 on the NL-2XX series controller. Connect the lead labeled “Fan V+” to the positive(+) output terminal of a 24VDC power supply. Connect the lead labeled “Fan GND” to the negative(-) output terminal of a 24VDC power supply. Connect the lead labeled “Shield” to chassis ground. 6. Connect the two leads labeled “RING 1, 2 V+” & “RING 3 V+” to the same positive(+) output terminal of the power supply or controller. Connect the two leads labeled “RING 1, 2 -” & “RING 3 -” to the same negative(-) output terminal of the power supply or controller. Connect the lead labeled “Shield” to chassis ground. 7. Connect Pin 1 of the M12-M connector to the positive(+) output terminal of the power supply or controller. Connect Pin 3 of the M12-M connector to the negative(-) output terminal of the power supply or controller. Connect the shell of the M12-M connector to chassis ground. Pins 2 and 4 are not used. Copyright ©2010 Microscan Systems, Inc. www.microscan.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : No XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Create Date : 2010:04:19 17:11:30-04:00 Metadata Date : 2011:08:08 12:43:22-07:00 Modify Date : 2011:08:08 12:43:22-07:00 Creator Tool : Adobe InDesign CS3 (5.0.4) Thumbnail Format : JPEG Thumbnail Width : 256 Thumbnail Height : 256 Thumbnail Image : (Binary data 10185 bytes, use -b option to extract) Instance ID : uuid:9dd6df46-ac65-4be9-baad-0ff9f6f99b59 Original Document ID : xmp.did:D5800130202611688507D49043955069 Document ID : adobe:docid:indd:7ada5aeb-073b-11df-a7de-be08506ea2fc Rendition Class : proof:pdf History Action : created, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved History Instance ID : xmp.iid:D5800130202611688507D49043955069, xmp.iid:E178A97C219A11688507D49043955069, xmp.iid:E178A97D219A11688507D49043955069, xmp.iid:E178A97F219A11688507D49043955069, xmp.iid:E178A980219A11688507D49043955069, xmp.iid:E178A981219A11688507D49043955069, xmp.iid:1563EC8321A611688507D49043955069, xmp.iid:1563EC8421A611688507D49043955069, xmp.iid:1563EC8621A611688507D49043955069, xmp.iid:1563EC8721A611688507D49043955069, xmp.iid:1563EC8821A611688507D49043955069, xmp.iid:531F6F3121AF11688507D49043955069 History When : 2010:01:15 10:51:27-05:00, 2010:01:15 10:54:44-05:00, 2010:01:15 10:54:44-05:00, 2010:01:15 11:06:40-05:00, 2010:01:15 11:06:40-05:00, 2010:01:15 11:57:08-05:00, 2010:01:15 12:17:40-05:00, 2010:01:15 12:17:40-05:00, 2010:01:15 12:39:26-05:00, 2010:01:15 12:41:09-05:00, 2010:01:15 12:49:28-05:00, 2010:01:15 13:39:16-05:00 History Software Agent : Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0 History Changed : /, /metadata, /metadata, /;/metadata, /, /metadata, /;/metadata, /, /, /, / Derived From Instance ID : xmp.iid:1563EC8321A611688507D49043955069 Derived From Document ID : xmp.did:E178A980219A11688507D49043955069 Derived From Original Document ID: xmp.did:D5800130202611688507D49043955069 Derived From Rendition Class : default Manifest Link Form : ReferenceStream, ReferenceStream Manifest Placed X Resolution : 150.00, 300.00 Manifest Placed Y Resolution : 150.00, 300.00 Manifest Placed Resolution Unit : Inches, Inches Manifest Reference Instance ID : uuid:229C1150196D11DF960CEC6F3FC6B53E, xmp.iid:59F2D171B8B9DE119EF6AD6A4AAF49EF Manifest Reference Document ID : uuid:95E657032FEFDE11AD1AA48928C286E9, xmp.did:58F2D171B8B9DE119EF6AD6A4AAF49EF Doc Change Count : 888 Format : application/pdf Title : Dark Field Series Illuminator Configuration Guide Creator : Producer : Adobe PDF Library 8.0 Trapped : False Page Count : 2 Page Layout : SinglePage Warning : [Minor] Ignored duplicate Info dictionaryEXIF Metadata provided by EXIF.tools