MS Connect 210 Ethernet Quick Start Guide Msconnect210quickstartguide
2009-05-25
: Microscan Msconnect210Quickstartguide msconnect210quickstartguide 3d69ac70-894c-490a-a045-eaca78575f5b _att
Open the PDF directly: View PDF
.
Page Count: 8
| Download | |
| Open PDF In Browser | View PDF |
MS-Connect 210 Ethernet Quick Start Guide P/N 83-212212 Rev A Power-On the System Step 1 — Power-On the System When your reader is connected to the MS-Connect 210 and all other cabling is connected and secured, it is safe to turn on the system. Power supply cable (97-100004-15) Set the Power switch to ON to cycle power. 2-2 MS-Connect 210 Ethernet Quick Start Guide MS-Connect 210 Ethernet Quick Start Guide Step 2 — Select and Identify Device Using ESP When you run ESP, you will see the model menu shown below. Select the MS-Connect 210 by double clicking on the MS-Connect 210 button, or by clicking it once and then clicking OK. Click the button showing the MS-Connect 210. The MS-Connect 210 view (shown below) will then appear. Click Search to locate your MS-Connect 210. The MS-Connect 210’s IP address and MAC address will appear in this field. Important: The unit’s MAC address is printed on the top of the Ethernet module inside the box. Click Revert to match all settings to the selected MS-Connect 210’s current settings. MS-Connect 210 Ethernet Quick Start Guide 2-3 Set Network Parameters Step 3 — Set Network Parameters You can use ESP to change Ethernet settings. Clicking Send and Save updates the settings in the MS-Connect 210’s Ethernet module. The firmware version, MAC address, and IP address will automatically populate the fields shown at left. Select the appropriate Subnet Mask, Gateway address, and TCP port. Send and Save network parameters. 2-4 MS-Connect 210 Ethernet Quick Start Guide MS-Connect 210 Ethernet Quick Start Guide Step 4 — Set COM Port Parameters The serial port settings of the MS-Connect 210 must match those of the reader for Ethernet communication to be successful. Click here to communicate with readers via TCP/IP connection. Note: This option can also be configured in the ESP Preferences dialog. Set Baud Rate, Parity, Stop Bits, and Data Bits to match the corresponding settings in the connected reader. Send and Save COM port parameters. MS-Connect 210 Ethernet Quick Start Guide 2-5 Select Reader Model and Connect Step 5 — Select Reader Model and Connect Once the MS-Connect 210’s Ethernet and serial port settings are configured, click the Switch Model button and select your reader model from the dropdown menu. If your reader model does not appear on the dropdown menu, select New Model to bring up the model menu shown below. When your reader is selected, select Settings from the Connect dropdown menu in ESP’s menu toolbar. In the Connection Settings dialog, select the TCP/IP tab, set the previously configured IP address and TCP port, and click Connect. When a connection is established, you can begin configuring the reader in ESP. 2-6 MS-Connect 210 Ethernet Quick Start Guide MS-Connect 210 Ethernet Quick Start Guide Step 6 — Configure the Connected Reader Each Microscan reader has different configuration requirements. Refer to the User’s Manual for the Microscan reader or readers being used in your application. Once the reader is configured, you can begin communicating via Ethernet. Important: If the reader’s settings for baud rate, parity, stop bits, or data bits are changed, you must reconfigure those settings in the MS-Connect 210 to match the new settings in the reader. See Set COM Port Parameters. Step 7 — Begin Active Operation of System For detailed information about customizing MS-Connect 210 settings for EtherNet/IP™, assigning an IP address without using ESP, or using a star network topology in industrial automation applications, refer to the MS-Connect 210 User’s Manual. For further details about implementing EtherNet/IP, visit the Open DeviceNet Vendor Association (ODVA™) website: http://www.odva.org/default.aspx For additional information about the MS-Connect 210, a specific Microscan reader, Microscan software, application information, or any other questions or concerns, you can submit a Helpdesk Request on the Microscan website: http://www.microscan.com/support/helprequest.htm MS-Connect 210 Ethernet Quick Start Guide 2-7 Begin Active Operation of System 2-8 MS-Connect 210 Ethernet Quick Start Guide
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Page Mode : UseNone XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Format : application/pdf Title : MS-Connect 210 Ethernet Quick Start Guide Creator : Create Date : 2007:03:21 14:17:56Z Creator Tool : FrameMaker 7.1 Modify Date : 2007:09:13 12:42:57-07:00 Metadata Date : 2007:09:13 12:42:57-07:00 Producer : Acrobat Distiller 8.0.0 (Windows) Document ID : uuid:0e548b17-1339-4361-996a-92dc3fd60d8e Instance ID : uuid:c9cde6e5-51e2-4f26-9ec8-2abf5f086425 Page Count : 8EXIF Metadata provided by EXIF.tools