QX 870 Industrial Raster Scanner Quick Start Guide Qx870quickstartguide
2009-10-07
: Microscan Qx870Quickstartguide qx870quickstartguide 06e7034e-039d-4d46-953c-9e09dabba0ec _att
Open the PDF directly: View PDF
.
Page Count: 2
| Download | |
| Open PDF In Browser | View PDF |
Quick Start Guide Step 1 — Check Hardware Step 2 — Connect the System QX-870 Industrial Raster Scanner Important: When connecting Ultra-Lock cordsets to the QX-870 and QX-1, align the pins first and then push the connector into place. Do not twist the connectors, as this will bend the pins. Important: Do not attempt to power more than four scanners with a single power supply in a daisy chain configuration. Add a QX-1 and one power supply for every four additional scanners in the daisy chain. RS-232 Standalone (with QX-1) Standalone (without QX-1) Hardware Required 1. Connect the Serial Communication Cable from “A” on the QX-870 to “2” on the QX-1. 2. Connect the host cable from “1” on the QX-1 to the host computer. 3. Connect the photo sensor to “T” on the QX-1. 4. Connect the power supply to “3” on the QX-1. 5. Plug in the power supply. Ethernet Caution: Be sure that all connections are secure BEFORE applying power to the system. Always power down BEFORE disconnecting any cables. Item 1 2 3 4 5 6 7 8 P/N 83-110870 Rev B Step 3 — Position Scanner 1. Place a test symbol in a location with as little ambient light as possible. 2. Position the scanner at the focal distance used in your application. 3. Align the test symbol with the scanner’s field of view. 4. Tip the scanner relative to the test symbol to avoid glare from specular reflection. axis Skew Bar code label Tilt axis Tilt Symbol Maximum skew, tilt, Scanner and pitch: ±30° Pitch Pitch axis Scanner Scan line Description QX-870 Industrial Raster Scanner QX-1 Interface Device QX Cordset, Common, M12 12-pin Plug to M12 12-pin Socket, 1 m QX Cordset, Host, Serial, M12 12-pin Plug to DB9, 1 m QX Cordset, Host, Serial, M12 12-pin Socket to DB9, 1 m QX Power Supply, M12 12-pin Socket, 1.3 m QX Cordset, Host, Ethernet, M12 8-pin Plug to RJ45, 1 m QX Photo Sensor, M12 4-pin Plug, NPN, Dark On, 2 m Part Number FIS-0870-XXXXG 98-000103-01 61-000162-01 61-000152-01 61-000153-01 97-000003-01 61-000160-01 99-000020-02 1. Connect the Ethernet Cable from “B” on the QX-870 to the network. 2. Connect the power supply to “A” on the QX-870. 3. Plug in the power supply. Note: Additional cordsets and accessories are available in the Microscan Product Pricing Catalog. Step 4 — Install ESP ESP Software can be found on the Microscan Tools CD that is packaged with the QX-870. 1. Follow the prompts to install ESP from the CD. 2. Click on the ESP icon to run the program. Step 5 — Select Model When you start ESP, the model menu will appear: Note: ESP can also be installed from the Download Center at www.microscan.com. Refer to the QX-870 Industrial Raster Scanner User’s Manual for detailed information about using ESP to configure the QX-870. 1. Click the button showing the QX-870. 2. Click OK. Note: You can also simply double-click the button showing your scanner to make your selection. 3. Click Yes when this dialog appears: Note: If you need to select another model later, click the Switch Model button near the top of the screen or use Model > New Model in the menu toolbar. Copyright ©2009 Microscan Systems, Inc. Step 6 — Connect Step 6 — Connect (cont.) Step 6 — Connect (cont.) RS-232 Ethernet TCP/IP Ethernet TCP/IP (cont.) To connect using the Connection Wizard: • Click Connect on the menu toolbar, and then select Connection Wizard. • Select RS-232. • Configure RS-232 settings as required by the application, and click Connect. To connect using the Connection Wizard: • Click Connect on the menu toolbar, and then select Connection Wizard. • Select Ethernet. • Configure Ethernet settings as required by the application, and click Connect. When the QX-870 is connected, incoming symbol data can be displayed in the Terminal, as shown below. • When a connection is established, the green indicator in the status bar at the bottom right of the screen will be visible: • When a connection is established, the green indicator in the status bar at the bottom right of the screen will be visible. Important: The scanner is in Continuous Read Mode by default. For best connection results, be sure that no decodable symbols are within the scanner’s field of view while attempting to connect. Important: The scanner is in Continuous Read Mode by default. For best connection results, be sure that no decodable symbols are within the scanner’s field of view while attempting to connect. Step 7 — Test Read Rate Read Rate indicates the number or percentage of successful decodes per second achieved by the scanner. 1. Click the Test button in ESP’s EZ Mode to start the Read Rate test. Symbol data and read rate percentage information should appear in the Symbol Information table. The Read Rate LEDs on the side of the QX-870 will indicate the percentage of successful decodes per second. 2. Click Stop to end the Read Rate test. Note: Read Rate can also be tested using the Read Rate interface in Utilities. Step 8 — Configure the Scanner Click the App Mode button to make configuration changes to the scanner. The following modes are accessible by clicking the buttons at the top of the screen: • • • • • • • • Refer to the QX-870 Industrial Raster Scanner User’s Manual for information about how to test read rate using serial commands or the scanner’s EZ button. Copyright ©2009 Microscan Systems, Inc. Click the EZ Mode button to return to EZ Mode. Click the Autoconnect button to establish communications. Click the Send/Recv button to send or receive commands. Click the Switch Model button to open the model menu, or to return to the previous model. Click the Parameters button to show the tabbed tree control views. Click the Setup button to show the tabbed interface views. Click the Terminal button to display decoded symbol data and to send serial commands. Click the Utilities button to access Read Rate, Counters, Device Control, Differences from Default, Master Database, Digital Bar Code, and Firmware. For further details, see Microscan ESP Help in the dropdown Help menu. Step 9 — Save Changes To make changes to configuration settings in the tree controls: 1. Left-click on the + to expand the desired tree. 2. Double-click on the desired parameter and click once in the selection box to view options. 3. Place your cursor in the selection box, scroll down to the setting you want to change, and click once on the setting. 4. Left-click on the open screen to complete your selection. 5. Right-click on the open screen and select Save to Reader to implement the command in the scanner. Saving Options • Send, No Save. Changes will be lost when power is re-applied to the scanner. • Send and Save. This activates all changes in current memory and saves to the scanner for power-on.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Page Mode : UseNone XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Producer : Acrobat Distiller 8.1.0 (Windows) Creator Tool : FrameMaker 8.0 Modify Date : 2009:09:30 15:48:14-07:00 Create Date : 2005:05:17 07:56:12Z Metadata Date : 2009:09:30 15:48:14-07:00 Format : application/pdf Title : QX-870 Industrial Raster Scanner Quick Start Guide Creator : Document ID : uuid:ece8426e-7957-4d50-912a-d6004fdd769f Instance ID : uuid:f898e783-cb96-4ddf-8b24-f8f850356dfb Page Count : 2 Page Layout : SinglePageEXIF Metadata provided by EXIF.tools