Microsensys UNI13Q60232X RFID Read/Write Module UNI13-Q60-232 User Manual RFID

Microsensys GmbH RFID Read/Write Module UNI13-Q60-232 RFID

Users Manual

                       User Manual UNI13-Q60-232 / UNI13-Q60-USB   RFID read/write module 13.56 MHz closed coupling   iID®Reader
 Page 2    ©2011 microsensys GmbH  User Manual UNI13-Q60-232 / -USB                                         Contact/Copyright  microsensys GmbH Office Park im GVZ In der Hochstedter Ecke 2 99098 Erfurt Germany  tel:    +49 (0) 3 61/5 98 74-0 fax:    +49 (0) 3 61/5 98 74-17 e-mail:    info@microsensys.de homepage:   www.microsensys.de
 User Manual UNI13-Q60-232 / -USB     ©2011 microsensys GmbH  Page 3 FCC Compliance Statement               These  devices  comply  with  part  15  of  the  FCC  Rules.  Operation  is  subject  to  the following two conditions:   1.  These devices may not cause harmful interferences;  2.  These devices must accept any interference received, including interference      that may cause undesired operation.  The  following  figures  list  the  Grant  by  FCC  ID  Number  for  each  of  the  following devices:      UNI13-Q60-232    FCC ID:  ZLCUNI13Q60232X     UNI13-Q60-USB    FCC ID:  ZLCUNI13Q60USBX  Please refer to the FCC’s website ( http://www.fcc.gov/ ) to view the grant and related documentation.  CAUTION ! Exposure to Radio Frequency Radiation. The radiated output of this device is far below the  FCC  radio frequency  exposure  limits.  Nevertheless, the device  shall  be  used in such  a  manner  that  the  potential  for  human  contact  during  normal  operation  is minimized.  In  order  to  avoid  the  possibility  of  exceeding  the  FCC  radio  frequency exposure limits, human proximity to the antenna shall not be less than 20cm (8inches) during  normal  operation.  These  devices  may  not  be  co-located  with  any  other transmitter or transmitter antenna.  NOTE: This  equipment  has  been  tested  and  found  to  comply  with  the  limits  for  a  Class  A digital  device,  pursuant  to  part  15  of  the  FCC  Rules.  These  limits  are  designed  to provide  reasonable  protection  against  harmful  interferences  when  the  equipment  is operated  in  a  commercial  environment.  This  equipment  generates,  uses,  and  can radiate radio frequency energy and, if not installed and used in accordance with the instruction  manual,  may  cause  harmful  interference  to  radio  communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.  Changes or modifications  not expressly approved by  Microsensys  GmbH could  void the user’s authority to operate the equipment described in the manual.
 Page 4    ©2011 microsensys GmbH  User Manual UNI13-Q60-232 / -USB Introduction                                The RFID read/write module UNI13-Q60 is part of the inductive read/write- identification system iID®3000 and serves for the reading and writing of 13.56MHz RFID transponders. It supports RFID transponder systems like  iID®, TELID®, ISO15693, I-CODE™, tag-it™, my-D™,  LEGIC®  and  further.  The  UNI16-Q60  is  available  in  two  types,  with  a  serial interface and with a USB interface to the host computer. This product is designed for use in industrial environment together with a host, such as handheld devices or laptops. The small size and the integrated antenna on the front side of  the  UNI13-Q60  module  allow  a  simple  use  in  many  different  applications.  For  the mechanical mounting of the module four threads for screws on the back side may use.  Please read this document carefully to prevent damage and unwanted results.
 User Manual UNI13-Q60-232 / -USB     ©2011 microsensys GmbH  Page 5 Technical Data               Housing:      plastic case with integrated antenna, epoxy molded  Size:       55mm x 29mm x 12mm   (without cable or connector)  Temperatur range:    Operating:  0 ... +50 °C         Storage:    -25 ... + 70°C  Power supply (VCC):  5V +/- 5%, ripple <50mV  Current consumption:  typ. 100mA  (active mode, with active RF field)         typ. 10mA  (idle mode, without RF field)  Connector:    serial interface:    USB interface:         BLR 125Z,    standard USB Type A         Fischer Elektronik  Voltage Level:    serial interface:    USB interface:         high:    0.85*VCC ... VCC  according USB 1.1 standard         low:     GND ... 0.15*VCC  Protocol:      baudrate:   57.6 kabaud         data bits:   8         stop bits:   1         parity:    no  Software interface:    iID® Driver Engine for Windows   Supported Commands:  see actual API documentation  of iID® Driver Engine
 Page 6    ©2011 microsensys GmbH  User Manual UNI13-Q60-232 / -USB  RFID air interface           Carrier frequency:    13.56MHz +/- 7kHz  RF output power:    200mW  Implemented standards:  ISO15693, ISO14443B  Anticollision:    not implemented  Antenna type:    P13  Operating distance:   0 … 50 mm         depending on transponder type and environment conditions        Ordering information              Product Product code UNI13-Q60-232 25.26.603.02 UNI13-Q60-USB 25.29.600.02
 User Manual UNI13-Q60-232 / -USB     ©2011 microsensys GmbH  Page 7  Safety instructions             ●  The  device  may  only  be  used  for  the  intended  purpose  designed  by  for  the manufacturer. ●  Unauthorized changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or  injuries.  Such  unauthorized  measures  shall  exclude  any  liability  by  the manufacturer. ●  The  liability-prescriptions  of  the  manufacturer  in  the  issue  valid  at  the  time  of purchase  are  valid  for  the  device.  The  manufacturer  shall  not  be  held  legally responsible for inaccuracies, errors, or omissions in the manual or automatically set parameters for a device or for an incorrect application of a device. ●  Repairs may only be executed by the manufacturer. ●  Installation, operation,  and maintenance  procedures should  only be  carried  out  by qualified personnel. ●  Use  of  the  device  and  its  installation  must  be  in  accordance  with  national  legal requirements and local electrical codes. ●  When working on devices the valid safety regulations must be observed.       Questions? Contact us: microsensys GmbH Office Park im GVZ In der Hochstedter Ecke 2 D-99098 Erfurt Germany  e-mail:  info@microsensys.de tel:  +49 361 59874 0 fax:  +49 361 59874 17     © 2011 microsensys GmbH  Every  reproduction  of the  document  in  hand  or storing  in electronic  media,  as  well  as translation  in other languages is not allowed without a written approval of MICROSENSYS GmbH. All rights reserved.
 Page 8    ©2011 microsensys GmbH  User Manual UNI13-Q60-232 / -USB

Navigation menu