Microsensys UNI13Q60232X RFID Read/Write Module UNI13-Q60-232 User Manual RFID

Microsensys GmbH RFID Read/Write Module UNI13-Q60-232 RFID

Users Manual

Download: Microsensys UNI13Q60232X RFID Read/Write Module UNI13-Q60-232 User Manual RFID
Mirror Download [FCC.gov]Microsensys UNI13Q60232X RFID Read/Write Module UNI13-Q60-232 User Manual RFID
Document ID1508254
Application IDVtJd+0njyONCTUsRUdn4kQ==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize14.06kB (175772 bits)
Date Submitted2011-07-25 00:00:00
Date Available2011-07-25 00:00:00
Creation Date2011-07-22 17:11:04
Producing SoftwareMicrosoft® Office Word 2007
Document Lastmod2011-07-22 17:11:04
Document TitleRFID
Document CreatorMicrosoft® Office Word 2007
Document Author: Wicht

®
iID Reader
User Manual
UNI13-Q60-232 / UNI13-Q60-USB
RFID read/write module
13.56 MHz closed coupling
Contact/Copyright
microsensys GmbH
Office Park im GVZ
In der Hochstedter Ecke 2
99098 Erfurt
Germany
tel:
fax:
e-mail:
homepage:
+49 (0) 3 61/5 98 74-0
+49 (0) 3 61/5 98 74-17
info@microsensys.de
www.microsensys.de
Page 2
©2011 microsensys GmbH
User Manual UNI13-Q60-232 / -USB
FCC Compliance Statement
These devices comply with part 15 of the FCC Rules. Operation is subject to the
following two conditions:
1.
These devices may not cause harmful interferences;
2.
These devices must accept any interference received, including interference
that may cause undesired operation.
The following figures list the Grant by FCC ID Number for each of the following
devices:
UNI13-Q60-232
FCC ID: ZLCUNI13Q60232X
UNI13-Q60-USB
FCC ID: ZLCUNI13Q60USBX
Please refer to the FCC’s website ( http://www.fcc.gov/ ) to view the grant and related
documentation.
CAUTION !
Exposure to Radio Frequency Radiation. The radiated output of this device is far below
the FCC radio frequency exposure limits. Nevertheless, the device shall be used in
such a manner that the potential for human contact during normal operation is
minimized. In order to avoid the possibility of exceeding the FCC radio frequency
exposure limits, human proximity to the antenna shall not be less than 20cm (8inches)
during normal operation. These devices may not be co-located with any other
transmitter or transmitter antenna.
NOTE:
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interferences when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference
in which case the user will be required to correct the interference at his own expense.
Changes or modifications not expressly approved by Microsensys GmbH could void
the user’s authority to operate the equipment described in the manual.
User Manual UNI13-Q60-232 / -USB
©2011 microsensys GmbH
Page 3
Introduction
The RFID read/write module UNI13-Q60 is part of the inductive read/write- identification
system iID®3000 and serves for the reading and writing of 13.56MHz RFID transponders.
It supports RFID transponder systems like iID®, TELID®, ISO15693, I-CODE™, tag-it™,
my-D™, LEGIC® and further. The UNI16-Q60 is available in two types, with a serial
interface and with a USB interface to the host computer.
This product is designed for use in industrial environment together with a host, such as
handheld devices or laptops. The small size and the integrated antenna on the front side
of the UNI13-Q60 module allow a simple use in many different applications. For the
mechanical mounting of the module four threads for screws on the back side may use.
Please read this document carefully to prevent damage and unwanted results.
Page 4
©2011 microsensys GmbH
User Manual UNI13-Q60-232 / -USB
Technical Data
Housing:
plastic case with integrated antenna, epoxy molded
Size:
55mm x 29mm x 12mm (without cable or connector)
Temperatur range:
Operating:
0 ... +50 °C
Storage:
-25 ... + 70°C
Power supply (VCC):
5V +/- 5%, ripple <50mV
Current consumption:
typ. 100mA
(active mode, with active RF field)
typ. 10mA
(idle mode, without RF field)
Connector:
serial interface:
USB interface:
BLR 125Z,
standard USB Type A
Fischer Elektronik
Voltage Level:
Protocol:
serial interface:
USB interface:
high:
0.85*VCC ... VCC
according USB 1.1 standard
low:
GND ... 0.15*VCC
baudrate:
57.6 kabaud
data bits:
stop bits:
parity:
no
Software interface:
iID® Driver Engine for Windows
Supported Commands:
see actual API documentation of iID® Driver Engine
User Manual UNI13-Q60-232 / -USB
©2011 microsensys GmbH
Page 5
RFID air interface
Carrier frequency:
13.56MHz +/- 7kHz
RF output power:
200mW
Implemented standards:
ISO15693, ISO14443B
Anticollision:
not implemented
Antenna type:
P13
Operating distance:
0 … 50 mm
depending on transponder type and environment conditions
Ordering information
Page 6
Product
Product code
UNI13-Q60-232
25.26.603.02
UNI13-Q60-USB
25.29.600.02
©2011 microsensys GmbH
User Manual UNI13-Q60-232 / -USB
Safety instructions
●
The device may only be used for the intended purpose designed by for the
manufacturer.
●
Unauthorized changes and the use of spare parts and additional devices which have
not been sold or recommended by the manufacturer may cause fire, electric shocks
or injuries. Such unauthorized measures shall exclude any liability by the
manufacturer.
●
The liability-prescriptions of the manufacturer in the issue valid at the time of
purchase are valid for the device. The manufacturer shall not be held legally
responsible for inaccuracies, errors, or omissions in the manual or automatically set
parameters for a device or for an incorrect application of a device.
●
Repairs may only be executed by the manufacturer.
●
Installation, operation, and maintenance procedures should only be carried out by
qualified personnel.
●
Use of the device and its installation must be in accordance with national legal
requirements and local electrical codes.
●
When working on devices the valid safety regulations must be observed.
Questions? Contact us:
microsensys GmbH
Office Park im GVZ
In der Hochstedter Ecke 2
D-99098 Erfurt
Germany
e-mail:
info@microsensys.de
tel: +49 361 59874 0
fax: +49 361 59874 17
© 2011 microsensys GmbH
Every reproduction of the document in hand or storing in electronic media, as well as translation in
other languages is not allowed without a written approval of MICROSENSYS GmbH.
All rights reserved.
User Manual UNI13-Q60-232 / -USB
©2011 microsensys GmbH
Page 7
Page 8
©2011 microsensys GmbH
User Manual UNI13-Q60-232 / -USB

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 8
Language                        : de-DE
Tagged PDF                      : Yes
Title                           : RFID
Author                          : Wicht
Creator                         : Microsoft® Office Word 2007
Create Date                     : 2011:07:22 17:11:04
Modify Date                     : 2011:07:22 17:11:04
Producer                        : Microsoft® Office Word 2007
EXIF Metadata provided by EXIF.tools
FCC ID Filing: ZLCUNI13Q60232X

Navigation menu