Document Title8

Microtek
ScanMaker V6USL
User's Manual
(for Windows)
M English
iv
o.
r:
if
LL
Copyrighi © 1999 by Mieroiek Inlnrrtuh'anul, Inc.
All rights reserved.
lmcmauonnl Busincss Machines Corporation. Windows and MS-DOS are trademarks of Microsoft Corporation. Other
product or company names are trademarks or registered trademarks of their respective holders
Important
materials.
Doc No. 149-002195, A
Micmlelt Lib, lnc, Mitrutek Inltmalinlul, Inc. Micmuk Europe BM
3715 Doolittl: Drive 5, Industry Easl Road 3 Max Euwtlazn 68
Redcndu Beach, ("A 90178-1226 Science Based industrial Park NL—3062 MA Rotterdam
Main“ 310-297-5000 Sales: 800-654-4160 Hstnchu. 30077, Taiwan. KOC. The NeLhzrlands
FAX. BIO-2975050 BBS: 310-297-5102 TEL: 885-3-5772155 TEL. 31-10-2425688
Technical Support“ 310-297-5151 FAX: SSS-35772598 FAX ill—104425699
AuloTech fax back system. 310—297-5101
http'l/wwwmicmtekusacom
- Reon‘ent/relocate the receivmg antenna.
- increase the separation between the equipment and receiver.
. Cant-tea the equipment inla an outlet on a circuit different from that to which the receiver is connected
- Consult the dealer or an experienced radio/IV technician for help.
computer or peripheral devices). Any changes or modifications not expressly approved by the party responsible lot
compliance could void the user's authority to operate this equipment.
Responsible Party: Microwk Lab, Inc.
3715 Donlittle Drive
Redondo Beach, a 902784226
us A
Telephone No: (310) 297-5000
Contents
Introduction ‘I
Basicchulret-ncnts u ,
Before You Begin
Unpacking your scanner and checking components .......
Installation under Windows 98 (USB Environment)
1. Verify the presence oIUSB .. ,
2, Connect the scanner and install scanne software
3. Test your scanner .
Troubleshooting . ,
lnslollufion under Windows 95 (SCSI Envtrenmoni) 9
1. Instalhngtheinteriacecard
2. Checking interface ward status,
3. Insmllingsoftwarzm. .
Using the Manuals ...............
. Resetting the scanner‘s SCSI ID if necessary
5. Connecting the scanner
6 Checking scanner status ..
7. Testing your scanner t
Troubleshooting..
Installation under Windows 98 (SCSI Envlronmenl) 16
Troubleshooting
Influlluiion under Windows NT 40 (SCSI Enviromnnni) 19
Resetting the scanner‘s SCSI ID if necessary .................
Installing the interface card
Checking your Vlfmdows NT configuration
Installing software .......
Connecting the scanner
Tasting your scanner
Troubleshooting u
OMfilfiNf“
Miscellaneous 22
Performingthe Power—on Test ......... a v .. 22
Returning your scanner [or repair
lampR/eplacement.v.... ..
iii
M Engllsh
u.
Componenis 23
Sp-cificulions 25
Important Notes 26
Choose only one interface 26
Power up notice .......... . .. 26
iv
Inirod ucfion
An image scanner is a device that captures and converts illustrations, graphics, photographs, or text into
electronic files that can be edited or enhanced and then incorporated in printed documents or multimedia
presentations,
The single-pass, 36-bit, high—resolution ScanMaker VGUSL has been specifically designed and engineered
for the discriminating scanner user, who demands rich, detailed images suitable for any prepress or
multimedia need.
The ScanMalter V6USL color flatbed scanner scans reflective originals, but also features media interface.
allowing you to upgrade for scanning 35mm positive or negative film in a variety of industry-standard
formats.
Francois
The ScanMaker V6USL is a dual-interface scanner which supports two Widely used interfaces -- USB and
SCSI, Choose either of them to connect with your computer for scan, If you are running Pentium
computer with a built-in USB interface under Windows 98, it is best to choose USE. If you have installed
SCSI card, in your computer, SCSI interface supports full-range of Windows family (i e, Windows 95,
Windows 98, and NT 4.0) for your ease of scan.
The ScanMaker V6USL includes 36-bit throughput capability for delivering images with more image dam
than 30- or 24~bit scanner are capable of capturing, superior optics and hardware components, as well as
Micmtelt ScanWizarcl scanner controller software.
7 l
T‘ zissbeamws 1 2151911248?" I
1L
Before You Begin
Unpacking your scanner and checking components
Open your scanner package and check the components as stated in your packing lisl If any component 15
missing, call Microlek Sales
USE Gibb
Melolok CD~ROM
SCSl termlnilof (25-pin)
sc5| able (25-25 pin)
Nolo: The SCSI interface card is not included With your scanner paLkage. For purchase, contact Micmtek.
‘H 2mm_pc.pss 2 i ZIW‘PIEPM
T I NWJQDGS a
To install under Windows 98, take the steps below:
1. Verify the presence of USB
2. Connect the scanner and install scanner
software
3 Test your scanner
1. Verify the presence of USB
Turn on your computer and check to see if USB is
implemented.
Visually inspect the USB pans of your computer,
USE Pom
If you cannot find Lb: USB ports at the back of
your computer, read the documentation that came
With your computer main board.
For computer main board with USB supported:
To enter BIOS settings and enable USB, see the
documentation that came with your computer.
Normally when the computer power is turned on,
before starting Windows 98, the computer will hint
you to press some keys for displaying BIOS menu.
For computer main board without USE supported:
In this case, USB can be implemented by an USB
add—on card. The BIOS settings for main board
type USB are not required.
2. Connect the scanner and
install scanner software
1. Connect the scanner to your computer. using
the USB mble that provided in the scanner
package.
Power adapter
2. Plug the power adapter to the power connector
at the back panel of the scanner\ and plug the
other end of the power adapter to your AC
power source at wall outlet.
Your scanner automatically turns on when the
power adapter is connected. The scanner has
no power switch. The green light on the front
of the scanner will start flashing, and alter a
few seconds, will remain on solid.
we». mam
Dents-ch
Francois
3. An Unknown Device message appears, asking
you to Sarah 3 new device.
English
lNi , U ml», m
rs
S“
§
u.
Click Next to continue.
4. Click “Search for the has! driver for your devnce
(Recommended)f to start searching.
5 Insert the Microtek CD—ROM into your CD—
ROM drive.
6. From the ”Add New Hardware Wizard" dialog
box, click “Next" to display the following
screen
LalurT'lndlcatas the location oiyour
(DD-ROM diva
On the above screen, E:\ indicates the default
CD-ROM drive location, Click Browse if your
CD-ROM drive is elsewhere. Click Next [0
continue. _Q
T Your scanner IS automatically detected, Click
Next to continue.
MhWPM
Click OK to prepare installing ScanWizard
driver programv
S The screen shows you the setuprexe program
in your Windows directory You should NOT
click on the OK button at this time. Instead,
click the Drives selection to choose the CD-
ROM.
9. Locate the correct setupexe program, which is
under E:\Scanwlz\Diskl directory
10, Click OK to continue.
ScanWizarcl lnstallanon has begun,
Francais
Micmtek ScanWizard is the Twain driver used
for the scanner to communicate With various
applications. ScanWizard cannot be used by
itszll and requires another program in order to
work,
Follow screen instructions to complete
installation. When installation is complete
Microtek ScamWiLard for Windows appears
as a folder on the Programs menu.
11. Install applicatten programs
Install each application software by clicking on
the individual pmgram options.
12 Install documentation reader
Click Adobe Acrobat Reader, then follow
screen instructions until installation is
complete. Acrobat Reader ls available for
reading the manuals on your CD~ROM.
25/99, 1.40 PM
3.
P’
r“
- . . a M English
Test your scanner
Restart Windows 98, Click Start. Settings, and
select Contral Paneli
Double-click on the System icon in Control
Panel, then select Device Manager from the
top
Double—click on “Imaging Device”. you can find
“Microtek ScanMaker V6USL" is listed. The
scanner is ready to sun.
Start up Scanner Test from the Micmtek
SennVWzard for “findews [older in the
Programs menu. When started up successfully.
the screen below appears,
54 Place a reflective document wnh faced down
on the scanner glass, Center the top of the
document along the horizontal ruler on the
scanner
Humoml rule!
6. Click the Flatbed button on the Mictouak
ScanTest program screen. A preview of your
image will be displayed in the Microtek
ScanTest wmdow. This indicates the Scanner
Test was successful an that the scanner is now
ready to be used.
7, Close and exit Micmtek Scanner Test.
For more details on how to operate your scanner
with ScanWizard, refer to the file ScanWizardpdfin
the folder Manuals on the CD—ROM
The Scanner Medal shows lhe scanner omnsded
in your wmpuler along with me scanner ID.
Damned lnfielfice
The Flat!“ button Is used hr pmviuw fellefiivo
malenal.
I! 35“ I; Installed, me TMA Man Is used lor
preview 35mm transparency or negative malarial
malarial
The Sclnnlr chock am as a mannerpmhu lo
verify the location ol your scamer and cheek the
scanmr ID,
The amnnfigunr Equlpm-m allows «no system to
Mate its own internal veterans» llle and Is usslul
when yw have arranged your setup or reeonflgursa
your symm.
ZIWJQDES a
2/5/99, ms PM
Troubleshoo ng
If Windows 98 annot detect USB device, follow Solulion A: Automalie swing
the steps below. 1. Select “lntel 82371AB PCI [0 use Universal
1, Check to make sure the SCSI cable or H“ (“mm"-
termmator is disconntected to your scanner. 2. Click the Remove button
2. Restart windows 98. Click Start. Settings, and
select Control Panel. 3. Restart Windows 98, your computer should be
able to detect the presence of ScanMaker
3 Double-click on the System icon in Control V6USL mu“
Panel and select Device Manager [rot-n the top.
Soluiion B: Manual sefling
4. Double—click “Universal serial bus controller" 1. Select “Intel 82371AB PCI to USB Universal
to display two-line messages indicating the Host Controller”.
detected chipset info, For example, “Intel
82371AB PC] to USB Universal Host 2. Click the Remove button.
Controller“ and “USB Root Hub".
3. To fix the problem, double-click the “Universal
serial bus controller" string to display the
following dialog box,
A yellow
exclamation
mark appeals
"on w me
message .
If an yellow exclamation mark appears in from
of the "Intel 82371AB PCI to USB Universal
Host Controuer" string, this means the driver
— Intel 82371 driver is not automatically
installed.
For example, your computer is shown as the
above figure. You have two solutions to
approach:
7 l “M” ’ ¢ ”mm” 1
“I l
4. Click “Update Driver" [0 display the driver The detected scanner is displayed in [he “Scanners
selection dialog box. and Cameras Properties" dialog box.
English
T:
1/2
e‘ m-usmmm
, Al (he left column‘ select “Intel"; the message
“Intel 82371AB PCI [0 USB Universal Host
Controller" will appear at right column Click
Finish [0 exit.
Option 2: Check it by clicking the “System” icon in
the Control Panel dialog box. Then click the
Device Manager tab, The detected scanner is
displayed in the Image Device item. ¢
6, Restart Windows 98, your computer should be
able to detect the presence of ScanMaker
V6USL scanner.
- . . Francals
To check the availability of SmnMaker V6U5L
scanner:
Option 1: Check it by clicking the “Scanners and
Cameras" icon in the Control Panel dialog box.
7 I "MN“ ° ¢ mm“ | l—
—| I 21nmo,_pc.pes a i
installation under Windows 95 (SCSI Environment)
To install under Vdeows 95, take the steps below:
Install the interface card in your computer
Check the interface card status
lristall software
Reset the scanners SCSI 1D if necessary
Connect the scanner and computer
Check the scanner status
Test your scanner
“993“.WN.“
1. Installing the interface card
Before installing the interface card, make sure you
turn oil your computer and peripherals Then
follow the steps below:
1. Shut down your computer and unplug the
power cord. Next, remove the cover from your
computer.
2. Look for an available PCI card slot (typically
white or ivory) in your computer. remove the
slot covert and insert the PC] SCSI card (e g
Adapts: AVA-290213) into the slot. Push the
card in to make sure it‘s seated all the way in
the slot.
Poi oomim
slot: (wisely
white or ivory)
This is important, as an improper card connection
Will make you unable to use your scanner. and
you will then have to remove the computer case
and restart the card all over again.
3 Replace the cover of the computer, then plug
the power cord hack in.
2. Checking interface card status
When you run Windows 95, the Adapts: AVA-
2902E SCSI adapter is detected and the driver is
automatically installed. Make your Windows 95
CD-ROM ready for use. Some computers may
prompt you to load Windows 95 software during
your installing AVA-2902E driver. Follow steps
below to check.
1. Turn on your computer, click Start, Settings.
and select Control Panel.
2. Double-click on the System icon in Control
Panel and select Device Manager from the top.
3, Double-click on “SCSI controllers" to display
the screen below,
The result 0!
the chedt is
dkplayed here.
The message “Adaptcc ARI-7850 PCI SCSI
Controller" displays indicates that the driver is
installed and the AVA-290215 interface card
worlc properly
if a conflict exists, either of the following will
occur:
- a yellow exclamation mark appears next to
the phrase:
G- Adaplec AIC-7850 PCI scst
Controller
. or _
- nothing is listed under “SCSI Controllers",
in either use, refer to the Troubleshooting
section.
m. 1mm
- - . M M English
7 l zissboeywwfi 10
3. Installing software
Insert the Mtcrotek CD—ROM into your (SD-ROM
drive. The Microtek Scanner Safiwarz installer
should come up automatically, and list the software
available for you, Click on each software program
in the order they appear on your screen to install
all software components.
Note, ljthe Mtcrotelt Scanner Software is not
automatically displayed, click Start, select Run and
type e:\aisetup (where e. is your CD-ROM drive),
S'lp I Install Microlek Seunwizurd
ScanWizard is a Twain driver used for the scanner
to Work With various applications. ScanWrzard
cannot be used by itself and requires another
program in order to work.
1. Click Micmrek ScanWiznrd. then follow
screen instructions to start installation.
2 During installation, choose “Adaptec SCSI
Interface Card‘ option as your interface type.
3. When installation is complete. the Microtelt
ScanWimrd for Windows 95 group appears as
a folder in the Programs menui
Slop 2 Install software upplicafion
The bundled image editing. OCR. and other
applications you receive depend on the scanner
model you purchase. Click each option on the
installer screen to install the software.
Slop 3 Inslull Mierohlt DCR
DCR is Microtek's proprietary color calibration
technology for use with Microtek color scanners
With DCR installed, your scanner is capable of
capturing extremely accurate color images.
Slap 4 lns'ull documenlalion under
Click Adobe Atrobat Reader, then follow screen
lnSlmCllOnS until installation is complete. Acrobat
Reader is necessary for reading the manuals on
your CD-ROM.
Using the Manuals
Other documentations for your scanner are
provided on the Microtek CD—ROM, To read the
documents, you will be using the Adobe Acrobat
Reader program. which is automatically launched
when you open the file for the manuals.
To open the manuals: Go to Manuals folder, and
locate the manual that you wish to View Double-
cltck on the file you want, and the manual is ready
to be Viewed or printed
IO
elm. mom
_-lL
4. Resetting the scanner’s SCSI
ID if necessary
This procedure is provided as a reference. You may
or may not need to change the SCSI ID on your
scanner.
A SCSI ID is a number assigned to each SCSI
device in your daisy chain to difi'erentiate the
devica from one another. The SCSI ID for your
Microtek scanner is factory-set to 6
You won't need to Change the SCSI ID on your
scanner unless another SCSI device on your system
(such as external hard drive, additional spanner,
etc.) is using the same number.
Locate the SCSI ID switch, use a small screwdriver
to turn the switch to the desired SCSI ID number.
Valid SCSI ID numbers are 0 to 6. SCSI ID 137, $8
and 39 are also not used
5. Connecting the scanner
Before connecting the scanner to your computer,
make sure the scanner driver (ScanWizard) is
installed. Take the following steps to connect.
1. Shut down your computer.
2. Connect the card and the scanner, using the
SCSI mhle that provided in the scanner
package. Make sure your computer are turned
05 when you perform the connection
Iermmatar
Power adapter
3. Plug the ZSeptn terminator to another 5&1
pon.
Plug the power adapter to the power connector
at the back panel of the scanner, and plug the
other end of the power adapter to your AC
power source at wall outletr
Your scanner automatically turns on when the
power adapter is connected. The scanner has
no power switch. The green light on the from
of the scanner will start flashing, and after a
few seconds, thI remain on solid,
5, Then power up your computer.
||
4. Resetting the scunner’s SCSI
ID if necessary
This procedure is provided as a reference. You may
or may not need to change the SCSI ID on your
scanner
A SCSI ID is a number assigned to each SCSI
device in your daisy chain to differentiate the
devices from one another The SCSI ID [or your
Microlek scanner is factory-set to 6
You won't need to change the SCSI ID on your
scanner unless another SCSI device on your system
(such as external hard drive, additronal scanner,
etc.) is using the same number.
Locate the SCSI ID switch. use a small screwdriver
to turn the swttch to the desired SCSI ID number
Valid SCSI ID numbers are 0 to 6. SCSI ID d7, 38
and 419 are also not used
5. Connecting Ithe scanner
Before connecting the scanner to your computer,
make sure the scanner driver (ScanWizard) is
installed. Take the [allowing steps to connect.
1. Shut down your computer
Zr Connect the mrd and the scanner, using the
SCSI cable that provided in the smnner
package. Make sure your computer are turned
off when you perform the connection,
Power aaapnsr
3. Plug the 25-pin terminator to another SCSI
port.
4. Plug the power adapter to the power connector
at the back panel of the scanner, and plug the
other end of the power adapter to your AC
power source at wall outlet.
Your scanner automatically turns on when the
power adapter is connected. The scanner has
no power switch. The green light on the front
of the scanner will start flashing, and after a
few seconds, W111 remain on solid
5. Then power up your computer.
11
T | msboaijes n ale/usurp» I 4»
—l l zwobwympflé |2
6. Checking scanner status
When running Windows. ALWAYS turn on the
scanner before the computer. If you don‘t‘
Windows will not be able to “see" your scanner,
1 Click Start, Settings, and select Control Panel.
2. Double-click on the System icon in Control
Panel and select Device Manager from the top.
3. The screen that appears displays the message
‘Microtek Scanners”. Double-click it, the
scanner model you connected shows under it.
The message
‘M‘mviek
Scanners“
displays.
IMlcatInu Ihe
scanner is
installed.
ll your system can't find your scanner, maybe SCSI
conflict happcns between your scanner and other
SCSI device. To resolve the conflict, refer to
Troubleshooting on page 14.
Terminator
A Terminator is apiece of electrical
or equipment installed at the end of a
SCSI chain to ensure that electrical
impulses are properly touted.
You probably won't need a terminator for your
installation. but because of varying SCSl standards.
there is no way to predict with absolute certainty
whether or not you need one.
You will need a terminator in the following
instances'
0 II you get odd symptoms after hooking up your
PC and scanner (such as communication errors
during seaming, in which your scanner can't
be “seen" by your computer), or if your PC
refuses to boot up properly after you installed
the scanner,
' If you are hooking up your PC in a daisy chain
to two or more SCSI devices (such as your
scanner and a CD—ROM drive). In this case, the
terminator should be on the last SCSI device in
the daisy chain.
Take note that in a daisy-chain connection,
different drivers come into play and complicated
configurations may result If you are not familiar
with the procedure for daisy chaining, consult a
technician on how to do this Microtek bears no
responsibility [or damages that may occur to
peripherals due to inexperienced handling.
SCSI device
ale/so. 525 FM
Jlm é}
7. Testing your scanner 4. Place a reflective document with faced down E
on the scanner glass. Center the top of the g
1. Rem“ Window; 95 Before ya“ “mm the document along the horizontal ruler on the “J
computer, make sure your scanner is on and scanner.
ready.
2. Click Start, Programs, Microlek Seanleard
for Windows 95, and then select Scanner
Test.
5 Click the Flatbed button on the Micmtek
ScanTest program screen, A preview of your
image will be displayed in the Microtek
ScanTest window. This indicates the Scanner
Test was successful an that the scanner is now
ready [0 be used‘
6 Close and em Mmrotek Scanner Test program.
-. - meais Deu'SCh
3 When started up successfully, the screen below
For more detaxls on how to operate your scanner
appears.
with ScanWizard, refer (a the file Scanleard.pdf1n
the folder Manuals on the CD-ROM.
1119 Scanner Modal thaws the scanner
manned In your compumr alang with
ma scanners sc5| m.
The “alcVBxx' massage mdlmes you
are uslng Adamec SCSI menace
card.
The Flllbid Manon IS used br preview mumlve
mtgrlnl.
ll SSYA is inslalled, (he TMA bum)" Is used
to! preview 35mm transparenw or negative
malarial matenaL
The sunner Chm sets an a scannerpmbu to
verify the location M your warmer and mock the
scanner ID.
The Riewmgur- Equip-mm allows lbs system
to updm- ls mm imemal "bronco ms and is
¥ useful whun you have changed yuur seIup or
reconfigured your system
13
‘ zvssbndyy: pas 1:4 215011423 PM I
7 I
English
T ‘ aissnmyfiws 14
T oubleshoofing
After installing the interface card in your cm—nputer
and connecting the scanner. you may find yourself
unable to use the scanner. This is usually due to
any of the situations described below.
Situation A Your interface card is not properly
seated in the PCI card slot on your
computer.
sllunttnn I Your interface card conflicts with
another device
sttunllon 4: Windows 95 can not recognize your
interface card.
Summon D If your interface card and scanner do
not seem to be working properly
See details below for resolving the individual
situations above.
Resolving situation A
Power down your computer, remove the AVA-
2902E interface card from your computer. Then r:—
install it, make sure the card is seated all the way in
and secured into the PCI card slot. The PC] card
slot normally appears in white or Mary.
Rosolving situation B
1. Click Start, Settings. and select Control Panel.
2. Double—click on the System icon in Control
Panel and select Device Manager from the top.
3. Double-click on “SCSI controllers" to display
the dialog box below.
A yeilow
exclamation
mark appears
next to the
NEW
‘Maplec AIC-
7850 PCI scsi
Controlsr.
4. Click on the Adaptec AlC-7850 PCl SCSI
Controller option, and then click Properties.
5. Select Resources from the top. The dialog box
gives you information about the Interrupt
Request (lRQ) and Input/Output (V0) address
settings, including whether a conflict happens.
6. If a conflict exists in Input/Output option, then
click Change Setting. Use the Up/Dawn arrow
keys to select a different range.
If DOM
haopan, the
oummityno
7. Next, select the interrupt/Request option, click
Change Setting, and use the Up/Down arrow
keys to select different IRQ number. If all lRQs
are taken, you need to Contact your dealer or
computer manufacturer to help on how to free
up an IRQ in this range.
Ctldt the
UpIDawn umw
Mona to select
lFlQ.
I4
215199, 225 PM
conflict; happen.
5. In the next menu, make a note of the Input/
Output (I/O) range setting. as well as Interrupt
Request (IRQ) number that Windows
recommends you
8. When all the settings are correct, click OK to
save the modifications, The dialog box should
now show the correct Interrupt Request and
Input/Output address settings. If you’re asked
to shut down your computer. select No, then
click Close. You will be asked whether you
wish to roster! your computer. Click Yes and
resmn your computer.
Rosolving situation C
1. Click Start, Settings, and select Contml Pmel.
2. Double—click Add New Hardware.
3. Click Next and select No for “Do you want
Windows to search for your new hardware?“.
7, When the “Add New Hardware Wizard" dialog
box appears, click Finish.
4. From the next menu. select SCSI controllers
and click Next.
6. Continue until the installation is completed.
Vdeows 95 will then ask if you want to shut
down your computer. Select No,
9, Click Start. Settings. and select Control Panel.
10. Double-click on the System icon in Control
Panel and select Device Manager from the top
11. Double—click on “SCSI controllers" to check
whether conflict happens.
If conflict exists, followtng the steps of Resolving
5. Select Adaptec on the left and “Adaptec AHA- Situation B (see page H) m reset l'“
294X/AlC-78XX PCI SCSI Controller" on the _ _
right. Cli ck Na“ 12. When all settings are correct, click OK to save
the modifications. The dialog box should now
show the correct Interrupt Request and Input/
Output address settings. If you’re asked to shut
down your computer, select No. then click
Close. You will be asked whether you Wish to
restart your computer. Click Yes and restart
your computer.
hsolving situation D
See the section Technical Ttps of Installation Guide
that came with your AVA-ZQOZE interface card.
15
‘l l ztlleerJe-NS is minnow l l‘
T‘ ziasbmywves is
Installation underWindows 93 (SCSi Environment)
Vlfindows 95 and 98 installation is very
similarr..Wiridows 98 just makes it easier to install
your interface card and software.
1. Install the AVA-ZQOZE interface card
(Refer to Step 1 on page 9)
Note: Windows 98 should automatically detect
your new hardware and install the proper drivers,
upon restarting your computer
2, Check interface card status
(Refer to Step 2 on page 9)
Note‘ [In conflict exits, refer to “Troubleshooting"
on this page.
TI
After installing the interface card in your computer
and connecting the scanner, you may find yourself
unable to use the scanner, This is usually due to
any of the situations dficnbed below:
situation-A Your interface card is not properly
seated in the PCI card slot on your
computer.
Silumiun B Your interface card conflicts with
another device,
sliuuiion c Windows 98 cannot recognize your
interface card.
Simufionb If your interface card and scanner do
not seem to be working properly.
See demils below for resolving the individual
situations.
Resolving situation A
Power down your computer, remove the AVA-
2902E interface card from your computer. Then re-
install it, make sure the card is sealed all the way in
and secured into the PCI card slot. The PC] card
slot normally appears in white or ivory.
ubleshooi
3, Install your software
(Refer to Step 3 on page 10)
4, Reset the scanner‘s SCSI [D it necessary
(Refer to Step 4 on page 11)
5. Connect the scanner
(Refer to Step 5 on page 11)
ii TESI your scanner
(Refer to Step 7 on page 13)
Rosolving situation B
1, Click Start, Settings, and select Control Panelr
2. Doubleflick on the System icon in Control
Panel and select Device Manager from the top.
3 Double-click on “SCSI controllers" to display
the dialog box below.
A yeiiw
osmium-flan
mam swears
next to the
massage
“Adana: Arc-
7860 PC! SCSI
Controller.
4. Click on the Adaptec AlC—7850 PC] SCSI
Controller option, and then click Properties.
16
mm, 2.23 m
J|w o
5. Select Resources from the top. The dialog box 7. When you get a “No conflicts" message is in the E
gives you information about the 3 resources: Conflicting device llSl, the Memory Range 5”
Interrupt Request (lRQJ. Memory Range, and conflict is resolved. Take the similar procedures “1
Input/Output range. Any conflict in the 3 on the Interrupt Request (IRQ) and Input/
resources is detected and displayed in the Output Range resources, If all of IRQs are
“Conflicting device list”. taken, you need to contact your computer
dealer to help on how to free up an IRQ for
6 To resolve the conflict. uncheck “Use automatic you,
settings”, then click to modify the individual
resource, one after another, until the message “No
conflicts" appears in the Conflicting deVioe list.
For example, to resolve the Memory Range
conflict, take these steps:
a) At the Resource type, double—click on the
Memory Range string, the Edit Memory
Range dialog box is displayed,
8 When the settings are all correct, click OK to
save the modifications. The dialog box should
now show the correct Intermpr Request.
u must Memory Rang. and Input/Output address
“ppm. mg settings,
“5399
shims here.
h) At the Value entry, use [112 Up/Down arrow
keys to select a dificrent range.
CIM the
UpIDwm
button: to
select
diliorenl If you’re asked to shut down your computer,
W‘ select No, then click Close, You will be asked
whether you wish to restart your computer.
Click Yes and restart your computer.
17
T ‘ ziasmaucme w 215mm?" ‘ l‘
Rosolving situation C
1. Click Start‘ Settings, and select Control Panel.
English
2‘ Double—click Add New Hardware.
Click Next and select No for “Do you want
VJindows to search for your new hardware?".
Deuisch
4. From the next menu, select SCSI controllers
and click Next,
Francais
5 Select Adaptec on the left and “Adaplec A10
7850 PC] SCSI Controller" on the right. Click
Next.
6. When the “Add New Hardvimte Wizard" dialog
box appears. click Finish.
7, When installation is complete. Windows 98
Will then ask if you want to shut down your
computer, Select No.
& Click Start, Settings, and select Control Panel
9, Doubledick on the System icon in Control
Panel and select Device Manager from the top.
10. Double—click on "SCSI controllers" to check
whether conflict happens.
ll conflict exists, follow the steps of Resulving
Situation B (see page 16) to reset ill
11. When settings are all correct, click OK to save
the modifimuuns, The dialog box should now
show the correct Interrupt Request‘ Memory
Range, and input/Output address settings If
you're asked to shut down your computer,
select No, then click Close. You will be asked
whether you Wish to mtan your computer.
Click Yes and restart your computer
Resolving situation D
See the section Technical Tips of Installation Guide
that came with your AVA-ZQOZE interface card.
_J 1
18
I zinsbudumpss is ' mm 225 m
T ‘ atssooauepes to
To install under Windows NT 4.0, take the steps
below:
Reset the scanner's SCSI lD if necessary
Install the interface card in your computer
Check your Windows NT configuration
Install software
Connect the scanner and computer
QwfiiflN?‘
Test your scanner
Part of the above procedures, especially to
hardware installation should refer to the previous
pages (Installation under Windows 95 section).
Descriptions below follow installation sequence,
but concentrated on Vlfindows NT 40
i. Resetting the scanners SCSI ID
if necessary
You may or may not need to change the SCSI ID on
your scanner, For more details on how to reset
your scanners SCSI lD, refer to Step 4 on page 11.
2. Installing the interface card
Before installing the interface card supplied With
your scanner, make sure you have turned all your
computer and peripherals Then refer to Step 1 on
page 9
3. Checking your Windows NT
configuration
When you run Windows NT, the Adaptec AVA-
29025 SCSI Host Adapter is denoted and the
driver is automatically installed. Follow the steps
below to check
r In Windows NT, click on the Start menu. go to
Programs. Administrative Tools (Common),
and select thdows NT Diagnostics. This will
bnng you [D the following partial screen shot.
. Click on the Resources tab to bring up the
following screen,
The “aicTexf
message
itdioates you
are new
AVA-EOE
SCSI Imertaee
and.
Number 05
appears.
imitating IHO
5 Is In use,
At this screen you see a list of IRQs that are
currently in use By clicking on the 1/0 Port
button at the bottom of the screen, you can see
a list of V0 addresses that are in user
This I/D
address Is
used try
AVMME
U0 P011
button.
19
ans/so, 225 m
interface card.
Enghsh
r:
LI.
ROM drive. The Microtek Scanner Software
From these Mo screens you have seen, the
available IRQ and 1/0 address for use with the
AVA-2902E interface card.
If the message “aic78xx” is not listed on the
screen, indicating the SCSI driver is not
installed; refer to the Troubleshooting section.
Installing software
Launch Vftndows NT 4.0, log in as
Administrator.
Insert the Microlek CD-ROM into your CD-
installer should come up automatically, and list
the available software [or you. Click on each
software program in the order they appear on
your screen to install all software components.
Note: If the Micmtelz Scanner Saltware Installer Is
not automatically displayed on the screen, click
Start, select Run and type ekdsetup (where e: is
the dnwz letter a] your CD—ROM),
Stop 3 Instull Mierotek DCR
DCR is Mtcrotek‘s proprietary color calibration
technology for use With Microtek color scanners.
With DCR installed, your scanner is capable of
capturing extremely accurate color images.
Stop 4 Install documentation reader
Click Adobe Acrobat Reader, then follow screen
instructions until installation is completed. Acrobat
Reader is necessary for reading the manuals on
your CD-ROM.
5. Connecting the scanner
Make sure your computer are turned off before
connection begins. Ste Step 5 on page 11 to
connect the sanner and computer.
- . . a DEUtSCh
Stop 1 Install Mierntek Scunwimrd
ScanWimrd is a Twain driver used [or the scanner
to work with various applications. Scanleard
cannot be used by itself and requires another
progarn in order to work.
1. Click Microtek ScanWiznrd, then follow screen
instructions to start installation
2. During installation, choose "Adxplec scst
Interface Card" as your interlace type.
3, Follow screen instructions to complete
installation. When installation is complete,
Microtek SmnWizard {or Windows NT
appears as a folder on the Programs menu
6. Testing your scanner
Restart your computer, and sum up Scanner Test
from the Microtek ScanVWut-d (or “Tint-lows NT
group, The scanner test reports the detected
scanner model and the interface card— aic78xx
You are now ready to scan. For more details, refer
to step 7 on page 13.
Stop 2 Install software application
The bundled image editing, OCR, and other
applications you receive depend on the scanner
model you purchase. Click each option on the
imtaller screen (0 install the software.
20
‘H army.“ an
awnszt PM
T ’ 21me5 at i
Troubleshooting
After installing the interface card in your computer
and connecting the scanner, you may find yourself
unable to use the scanner This is usually due to
any of the situations dscribed below:
siiuaiianA Your interface card is not properly
seated in the PCI card slot on your
computer.
The AVA-ZQOZE SCSI driver is not
properly installed in your computer.
Situation B
See details below for resolving the individual
situations above
Resolving situation A
Power down your computer, remove the AVA-
29025 interface card from your computer Then re-
install it, make sure the card 15 seated all the way in
and secured into the PCI card slot. The PCI card
slot normally appears in white or ivory
Resolving situation 8
1. Restart your computer. Stan up Windows NT
4.0.
2. Click Start, Settings, and select Control
Panel.
1 In the Control Panel window. find SCSI
Adapters and double click it. A window like
the following will appear,
drive!!!
not "Med
The Devices screen Will list any SCSI controllers
that may already have insmlled in your computer.
Nflk: Although lDE CD-ROM drives are not SCSI,
because of the way the driver 15 implemented,
Windows NT 4.0 will still list it on this screen
. Click on the Drivers tab, and click on the
Add... button to select Adapiec on the left and
"Adaptec AHA-294x/AHA—394X or AlC-78XX
PCI SCSI Controller” on the right to install.
mumixmmm.
mljlsmluwtm
The Adaptec card should now be listed as
“Adzptec AHA-294xlAHA-394X or AlC-7SXX
FCI SCSI Controller”, indicating the driver is
installed.
Restart your computer. Start up Windows NT
4.0, follow the step 3 on page 19 to check
“Windows NT configuration.
2!
215m. 2:45 FM
Deutsch
Frangais
MM
1.0
9.
LL
7 I Z‘WJc-DGE 22
Miscellaneous
In this section, you will learn the following topics.
- Perform the power—on sell-test
- Return your scarmer for repairs
Performing the Power-on Test
1. Connect the power adapter to the back of the
scanner.
2. Plug the power adapter into a wall outlet or
FOWCT source.
1 The scanner automatically turns on when the
power adapter is connected. The ScanMaker
VGUSL scanner has no power swrtch
The green light on the front of the scanner will
start flashing, and after a few seconds, will
remain on solid.
lnportarit: if the green light continua flashing
for more than a minute, contact your reseller.
Returning your scanner for repair
Your scanner has been built to exacting standards.
Just like any piece of electrical equipment,
however, your scanner or the delicate parts in it are
subject to wear and tear ant:l may malluncuon for
any number of reasons If your scanner needs to be
serviced or repaired, do the following:
For U.S. users:
- Call 310-297-5151 to obtain an RMA number
from Microtek Technical Support.
- Pack the smrmer in the original box without
any software, and send the interface card and
cables (only if applicable and asked to do so).
If you have lost the original box, you will need
to buy one from Microtek for a nominal fee,
- Send the scanner to Microtek Lab, Inc, 3715
Doolittle Drive, Redonclo Beach. CA 90278,
Attention RMA number .
Important: Make sure the RMA number is on the
outside address label and is visible. Packages
without an RMA number or with the wrong RMA
number on the outside of the box will be refused
and returned to sender.
For Canadian users:
Call Mierotek Technical Suppon. You will be given
an RMA number and address to where your
scanner can be sent for repair.
For users in parts other than the U.S. or
Canada:
Call your authorized dealer for further instructions.
Lump Replacement
The lamp inside your scanner is not user
serviceable and should be replaced if it dos not
come on or begins to flicker/dun after some time.
If the lamp requires replacement, call Microlek
Technical Support to get a Repair Merchandise
Authorization (RMA) number, and send the
scanner in for lamp replacement. Outside the US.
and Canadian. call your authorized Mrcrotek dealer
[or lamp replacement.
22
its/semen
Components
I, ScaanmVGUSL manner 4. USB cable
2. Poworadapmr' 5. Movmek CD—HDM
3. SCSI |armlnaml (ES-pin) e. 5CS|clb
Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : Yes
Create Date                     : 2001:06:28 07:21:55
Producer                        : Acrobat Distiller 4.0 for Windows
Modify Date                     : 2001:06:28 07:21:57-04:00
Page Count                      : 31
EXIF Metadata provided by
EXIF.tools
FCC ID Filing: EF9MRS-1200V6US

Navigation menu