Microwave Radio Communications HDX044D Microwave Downlink Transmitter User Manual HDX 1100 User and Tech

Microwave Radio Communications LLC Microwave Downlink Transmitter HDX 1100 User and Tech

HDX-1100 User & Tech Ref Manual

      HDX-1100  Aircraft/Terrestrial High Power HD Video Transmitter                                       User and Technical Manual  Manual Part No. 400613-1 Rev. 2 March 2010
           Copyright © 2010 Part number 400613-1 Printed in U.S.A. Authorized EU representative: Vislink PLC Quality Certification  Vislink is certified to ISO 9001:2008. The Vislink trademark and other trademarks are registered trademarks in the United States and/or other countries. Microsoft®, Windows®, and Internet Explorer® are registered trademarks of Microsoft Corporation in the United States and/or other countries. Proprietary Material  The information and design contained within this manual was originated by and is the property of Vislink. Vislink reserves all patent proprietary design, manufacturing, reproduction use, and sales rights thereto, and to any articles disclosed therein, except to the extent rights are expressly granted to others. The foregoing does not apply to vendor proprietary parts. Vislink has made every effort to ensure the accuracy of the material contained in this manual at the time of printing. As specifications, equipment, and this manual are subject to change without notice, Vislink assumes no responsibility or liability whatsoever for any errors or inaccuracies that may appear in this manual or for any decisions based on its use. This manual is supplied for information purposes only and should not be construed as a commitment by Vislink. The information in this manual remains the property of Vislink and may not be used, disclosed, or reproduced in any form whatsoever, without the prior written consent of Vislink. Vislink reserves the right to make changes to equipment and specifications of the product described in this manual at any time without notice and without obligation to notify any person of such changes. General Safety Information  The following safety requirements, as well as local site requirements and regulations, must be observed by personnel operating and maintaining the equipment covered by this manual to ensure awareness of potential hazards. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy. If not installed and used in accordance with the instruction manual, it may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. About this Manual  This manual is intended for use by qualified operators, installers, and service personnel. Users of this manual should already be familiar with basic concepts of radio, video, and audio. For information about terms in this manual, see Glossary of Terms and Abbreviations (Part No. 400576-1). Pay special attention to Notes, Cautions, and Warnings. Read Notes for important information to assist you in using and maintaining the equipment. Follow CAUTIONS to prevent damage to the equipment. Follow WARNINGS to prevent personal injury or death. Symbols  The following symbols may be on the equipment or in this manual: WARNING: General Warning. Risk of Danger.  Frame or Chassis Ground: Identifies the frame or chassis terminal. WARNING: Risk of Electric Shock.  Earth Ground: Identifies the earth ground terminal. CAUTION: Electrostatic Discharge.   Possible Damage to Equipment.  Fuse (either icon): Identifies fuses or their location.  Protective Earth Ground: Identifies any terminal intended for connection to an external conductor for protection against elec- tric shock in case of a fault, or the terminal on a protective earth electrode. Waste Electrical and Electronic Equipment (WEEE): The product must not be disposed of with other waste. You must dispose of the waste equipment by handing it over to a desig- nated collection point for recycling.       101 Billerica Avenue - Bldg. 6 North Billerica, MA 01862-1256 USA TEL:  800.490.5700 or +1.978.671.5700
    1  About the HDX-1100  The HDX-1100 Aircraft/Terrestrial High Power HD Video Transmitter (HDX-1100) (shown) is a lightweight and rugged transmitter that is suited for mobile and aircraft environments; able to withstand constant vibration, shock, temperature swings, and humidity. Common uses include law enforcement surveillance and video collection.  The HDX-1100 supports H.264/MPEG-2 and HD/SD. The HDX-1100 can transmit DVB-T COFDM digital transmission (QPSK, 16QAM, 64QAM)  consisting of a standard definition (SD) NTSC or PAL video signals or high-definition (HD) video signal (up to 1080i), plus two audio signals and an RS-232 data channel. The transmitter uses the MPEG-2 video compression format for high-quality imagery.  The amplifier operates at 8W for all bands except 4940-4990 MHz which is limited to 1.0W maximum.  Low power mode is typically 3 to 6 dB below the maximum rating.   You can control the HDX-1100 with the touch screen user interface (see Section 3), or an optional remote control unit (RCU) (see Section 4). You also can configure the HDX-1100 with a PC using a web browser (see Section 5).   2  Operating in Safety  Guidelines for safe operation are derived from OET bulletin 65, August 1997, as recommended by the Federal Communications Commission (FCC).   WARNING  High levels of RF power are present in the unit. Exposure to RF or microwave power can cause burns and may be harmful to health. Remove power from the unit before disconnecting any RF cables and before inspecting damaged cables and/or antennas. Avoid standing in front of high gain antennas (such as a dish antenna) and never look into the open end of a waveguide or cable where RF power may be present.   The HDX-1100, operated without an antenna, will not create RF energy exceeding 1.0 mW/cm2, the FCC limit for exposure. Connecting an antenna to the unit greatly enhances the potential for harmful exposure, and you must maintain a certain distance from the radiator. The following table shows the Maximum Permissible Exposure (MPE) safe distances from the antenna.  Antenna Gain (dB1) 0 2 3 5 11 Safe Distance (cm) 4 6 6 8 15 Safe Distance (in) 1.57 2.36 2.36 3.15 5.9    HDX-1100 User and Technical Manual  1
Note  Hazardous RF radiation limits and recommended distances may vary by country. Observe all applicable state and federal regulations when using this transmitter.  To perform calculations to understand the safe exposure margin (MPE), use the following formula suggested by OET 65. The calculations provided are for common antennas often utilized in the ENG environment.  Calculating MPE  EIRP = P * (10 ^ (G / 10)) = (antilog of G/10) * P  P = RF power delivered to the antenna in mW G = Power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna in centimeters S = MPE in mW/cm² (milliwatts per square centimeters) Conversions  dBi to numeric gain = Antilog (dBi/10) Feet to centimeters = Feet * 30.48 Centimeters to Feet = cm * .0328 4 π = 12.57 User Input  RF power delivered to the antenna = Watts Antenna gain (referenced to isotropic antenna) = dBi Distance from the center of radiation = Feet Calculation steps:  1.  [P] RF power input. Watts to milliwatts = Watts * 1000 2.  [G] Antenna gain dBi. Numeric gain = Antilog (dBi/10) 3.  [EIRP] Multiply P * G 4.  [R] Centimeters to feet = Centimeters * .0328 5.  Square R 6.  Multiply R² * 4π 7.  [S] Divide (R² * 4π) into EIRP S = Power Density in milliwatts per square centimeters.  Note  At frequencies above 1500 MHz, S must not be greater than 1.  Reference  FCC OET Bulletin 65, August 1997 - Evaluating Compliance with FCC Guidelines for Human Exposure to Radio Frequency Electromagnetic Fields        2  HDX-1100 User and Technical Manual
Power Density (mW/cm^2) The figure to the right is a typical graph for a Vislink HDX-1100 Transmitter and shows the permissible exposure distance for various antennas. Graphs and data will vary, based on the actual transmitter, output power, frequency, and antenna utilized. One plot provides the permissible output of the transmitter for digital modulation, and the other plot for analog modulation.      2   1.5   1   0.5   0   Maximum Permissible Exposure @ 200 milliWatts RF Power              0       0.5     1     1.5     2     2.5     3     3.5     4     4 .5     5     5.5     6     6.5     7     7.5     8 Distance in Feet         0dBi 2dBi 3dBi 5dBi 11dBi  Vislink, in accordance with the requirements set forth by the FCC, provides this information as a guide to the user and assumes the users of this equipment are licensed and qualified to operate the equipment per the guidelines and recommendations contained within the product user guides and in accordance with any FCC rules that may apply.   3  Setting the HDX-1100 With the Touch Panel  The touch panel screen on the front of the unit lets you control the HDX-1100 directly as described in the following sections.  3.1  Selecting a Preset  The HDX-1000 recalls the most recently saved preset when it is powered up. You can select from up to 16 factory or custom preset configurations.To select a preset, do the following:  1.  Press the PRESET key. 2.  Press the up and down arrows to choose the new preset you want. 3.  Press the SAVE key. If the SAVE key is not pressed within 5 seconds, the preset returns to the most recently used value and the selection mode is canceled.  3.2  Selecting the Audio Input Level  The HDX-1100 recalls the most recently saved audio input level setting when it is powered up. To select the input level for Audio 1 and Audio 2 between microphone or line level, do the following:  1.  Press the AUDIO 1 MIC/LINE or AUDIO 2 MIC/LINE key. 2.  Press AUDIO 1 MIC/LINE or AUDIO 2 MIC/LINE key to toggle between MIC or LINE level. 3.  Press the SAVE key.If the SAVE key is not pressed within 5 seconds, the audio level returns to the most recently used value and the selection mode is canceled.     HDX-1100 User and Technical Manual  3
  3.3  Selecting the RF Output Level  The HDX-1100 recalls the most recently saved RF output power level when it is powered up. To select between high or low power for the RF output level, do the following:  1.  Press the RF HI/LOW key. 2.  Press RF HI/LOW key to toggle between HI or LOW RF output level. 3.  Press the SAVE key to select the new RF Power output setting. If the SAVE key is not pressed within 5 seconds, the RF output level returns to the most recently used value and the selection mode is canceled.   4  Setting the HDX-1100 with the RCU  You can install the remote control unit (RCU) up to 100 feet from the HDX-1100 using a 3-wire serial interconnection and a power source. The following figure shows the RCU.                 Function Name Description Push Buttons RF PWR Turns the unit on and off. BRIGHTNESS Sets the display brightness to high (H), low (L), or automatic (A; light sensing). LED Displays STBY Indicates the HDX-1100 is in standby mode (not transmitting). XMIT Indicates the HDX-1100 is in transmit mode. DC OK Indicates DC Power is applied to the Remote Control Panel and transmitting. FAULT Indicates an error condition in the HDX-1100 transmitter. HI Indicates the HDX-1100 is in high RF output power mode. LO Indicates the HDX-1100 is in low RF output power mode. DIG Indicates the HDX-1100 is transmitting a digital signal. ANA Indicates the HDX-1100 is transmitting a analog signal. Rotary Switches RF PWR Sets the HDX-1100 to HI or LO power mode. PRESET Select from 1 to 16 presets. CHANNEL  LCD Display PRESET Displays the current preset number.  4  HDX-1100 User and Technical Manual
  Use a 9-pin RS-232 null-modem cable to connect the communication path between the RCU and the HDX-1100.  A receptacle at the rear of the controller supplies DC power to the RCU. Vislink provides the 2-pin Weidmuller connector (Part # 52104-2) to connect to the power receptacle at the rear of the controller. The required power range is from +10—+50 Vdc (negative ground only).  If the RCU displays a C in the preset window, the HDX-1100 has lost power or a communication error has occurred. If this happens, check the power and serial cable connections.   5  Setting the HDX-1100 with a PC  To set up your HDX-1100 with a PC, do the following:  1.  Connect a LAN cable to the network connection of a router or switch and the ethernet port on the HDX-1100. 2.  Open a web browser and type 192.168.4.150 into the URL address field and press Enter. To configure the parameters for each preset do the following:  1.  Select Video Settings from the Video drop down menu. The Encoder Settings screen appears.   2.  Configure the video and audio parameters as required for the preset and click Apply.                         5  HDX-1100 User and Technical Manual
    3.  Select Video Transport Stream from the Video drop down menu. The Transport Stream Settings screen appears.   4.  Configure the video and audio parameters as required for the preset and click Apply.                      5.  Select RF Settings from the Radio drop down menu. The RF Band Settings screen appears.   6.  Configure the video and audio parameters as required for the preset and click Apply.            6  HDX-1100 User and Technical Manual
    7.  Select Modulation Settings from the Radio drop down menu. The Modulation Settings screen appears.   8.  Configure the video and audio parameters as required for the preset and click Apply.        9.  Select Encryption Settings from the Radio drop down menu. The Encryption Settings screen appears.   10. Configure the video and audio parameters as required for the preset and click Apply.    Note  For 128-bit encryption, enter 32 hexadecimal characters.  For 256-bit encryption, enter 64 hexadecimal characters.                  HDX-1100 User and Technical Manual  7
    11. Select Ancillary Data from the Radio drop down menu. The Ancillary Data Settings screen appears.   12. Configure the video and audio parameters as required for the preset and click Apply.      13. Select Preset Settings from the Radio drop down menu. The Presets screen appears.   14. Configure the video and audio parameters as required for the preset and click Store.  5.1  Recalling a Preset Configuration from a PC  1.  Select Preset from the Radio drop down menu. 2.  Select the preset number and click Load. The relevant parameters will be populated under Video and Radio.  Note  The Encryption code will not display.  Click Logout to finish setting up the HDX-1100.               8  HDX-1100 User and Technical Manual
          6  HDX-1100 Specifications  The following figure shows the front, back, top, and side views of the HDX-1100.                   • Dimensions: 3.78 x 7.62 x 12.68 inches  • Weight: 7 pounds (3.2 kg)  • Operating temperature: –10 °C to +65 °C; storage temperature: –40 °C to +75 °C  • Humidity: up to 95% relative and non-condensing  • Altitude: up to 20,000 feet (6,000 m)  6.1  Band and Frequency Options  You can order the HDX-1100 for the following frequency bands.   Model  Band  Frequency Power Consumption Frequency Stability Frequency Step Size HDX-1100LS LS 1.7—2.5 GHz 44W 2.5 ppm 250 Khz HDX-1100S S 2.4—2.48 GHz 44W 2.5 ppm 250 Khz HDX-1100C1 C1 3.1—3.5 GHz 46W 2.5 ppm 250 Khz HDX-1100C2 C2 4.4—5.0 GHz 46W 2.5 ppm 250 Khz HDX-1100C3 C3 6.4—7.2 GHz 46W 2.5 ppm 250 Khz HDX-1100X X 8.1—8.5 GHz 48W 2.5 ppm 250 Khz  6.2  Video Input Connectors  The BNC female connectors provide HD-SDI/SDI and analog composite video outputs (SMPTE 170M).  Connector Pin Description  Signal  Ground Pin Signal Ring Ground    HDX-1100 User and Technical Manual  9
    6.3  RF OUT Connector  The RF Type N female connector attaches the antenna to the unit.  Connector Pin Description  Pin Signal Ring Ground  6.4  DC POWER and CONTROL Connector  DC voltage for the HDX-1100 is +10 Vdc to +32 Vdc with reverse voltage protection. Ensure that the power being supplied matches the power required by the equipment.  I/O connector 26-Pin Male D connector pin-outs are shown in the following table:  Connector Pin Description Pin Description  A +Vin P Serial CTRL Out B +Vin R N/C C N/C S N/C D Audio 1 In T Reserved E GND U Reserved F GND V Reserved G Audio 2 In W Reserved H N/C X Reserved J Data Channel In Y Reserved K GND Z Reserved L N/C a Reserved M Serial CTRL In b –Vin N Serial CTRL GND c –Vin  6.5  Modulation  •  DVB-T  COFDM EN300-744 COFDM QPSK COFDM 16QAM COFDM 64QAM           10  HDX-1100 User and Technical Manual
6.6 Encryption  Only one encryption scheme is available in a single firmware build.  •  AES 128-bit  •  AES 256-bit  Note  ASI input streams are not encrypted   6.7  RF Output Power  • High Power Mode: Enables PA and supplies output power of 10 W.  • Low Power Mode: Enables PA supplies output power of 1 W (or 10% of whatever the high power mode is for the PA).  •  Impedance: 50 Ohms (with VSWR <= 1.5:1)  •  Protection: Transmitters shall not be damaged by an infinite VSWR at any phase angle at the RF output ports for an indefinite time.  6.8  Audio Characteristics  •  Two audio inputs are to be supported which can be both line, both microphone, or one of each.  6.9  Video Input Format  •  ASI: 188 byte, EN50083-9  • HD-SDI: SMPTE 292M  -  1920x1080i@25fps -  1920x1080i@30fps -  1280x720@50 fps -  1280x720@60fps •  Composite: 1 Vpp RS170  -  720x480 NTSC 525 -  720x576 PAL 625 •  Wayside Data Rate: up to 115.2 kbps  •  Video input impedance: 75 Ohm unbalanced           HDX-1100 User and Technical Manual  11
7  Getting Support for Your HDX-1100  You can contact the Vislink Technical Support staff as follows:  24-hour Worldwide Technical Support  E-mail:  support@mrcbroadcast.com Telephone:  +1 978-671-5929 or 888-777-9221 Customer Service  E-mail:  customerservice@mrcbroadcast.com Telephone:  +1 978-671-5700 Press 3 Monday-Friday, 8AM-5PM EST USA When you contact Technical Support, include the following information:  •  Model number and serial number of the unit (located on a label on the bottom of each unit).  •  Approximate purchase date.  There are no supported field repairs to the HDX-1100. Return the unit for factory repair.   CAUTION  If you attempt field repair, you risk damaging your equipment. If your equipment is under warranty, you may also affect your warranty coverage. The HDX-1100 requires specialized test equipment and software to calibrate operating characteristics after repair.                                 12  HDX-1100 User and Technical Manual

Navigation menu