Miele Little Giant Pw 6065 Specification Sheet Deckblatt 6055 + 6065_Elektro_GB
2015-06-11
: Miele Miele-Little-Giant-Pw-6065-Specification-Sheet-748606 miele-little-giant-pw-6065-specification-sheet-748606 miele pdf
Open the PDF directly: View PDF .
Page Count: 11
Download | |
Open PDF In Browser | View PDF |
Installationsplan / Installation plan Installatietekening Plano de instalación Plan d`installation Plano de instalação Piano di installazione Σχέδιο εγκατάστασης Asennusohje Installasjonsplan Installationsplan G PW 6055 + PW 6065 AV/LP Materialnummer Änderungsstand Datum Zeichnung Datum Legende / / / / Mat. no.: Version: Drawing date: Legend date: 06 664 230 00 25.04.2005 02.05.2005 Technical datasheet PW 6055/PW 6065 AV/LP Electric (EL) Washer-extractor Heating: Legend: Circled, bold-type abbreviations: Connection required G Abbreviations surrounded by broken circle: Connection optional or required, depending on model Optional extras: UM BS Miele plinth UG/UO 5005 (UG = Box plinth/UO = Open plinth) Height Model Width UG (UO) Depth UG (UO) mm mm mm 300 609 622 mm mm mm mm 300 70 600 650 1. Standard voltage (as supplied) Frequency Rated load Fuse rating Connection cable, min. cross-section Length of supply lead (supplied) V Hz kW A mm² mm 2N AC 400 50 5.5 2 × 16 4 × 1.5 2000 Alternative voltage Frequency Rated load Fuse rating Connection cable, min. cross-section Length of supply lead (supplied) V Hz kW A mm² mm 1N AC 230 50 2.85 1 × 16 3 × 1.5 2000 2. Standard voltage (as supplied) Frequency Rated load Fuse rating Connection cable, min. cross-section Length of supply lead (supplied) V Hz kW A mm² mm 2N AC 400 50 5.5 2 × 13 4 × 1.5 2000 Alternative voltage Frequency Rated load Fuse rating Connection cable, min. cross-section Length of supply lead (supplied) V Hz kW A mm² mm 1N AC 230 50 2.85 1 × 13 3 × 1.5 2000 V Hz kW A mm² mm 1N AC 230 50 5.5 1 × 25 3 × 2.5 2000 Concrete platform Concrete platform optional (Min. quality B15) Recommended height Minimum height Recommended width Recommended depth Ensure good anchorage! (598) (615) Electrical connection convertible Machine connections: G 3. Standard voltage (as supplied) Frequency Rated load Fuse rating Connection cable, min. cross-section Length of supply lead with plug (supplied) convertible Country variations: Installationsplan PW 6055/PW 6065 AV/LP EL Stand: 02.05.2005 Seite 8 B V Hz kW A mm² mm 3N AC 400 50 4.8 3 × 10 5 × 1.5 2000 5. Standard voltage (as supplied) Frequency Rated load Fuse rating Connection cable, min. cross-section Length of supply lead (supplied) V Hz kW A mm² mm 2N AC 400 50 5.5 2 × 16 4 × 1.5 2000 Alternative voltage Frequency Rated load Fuse rating Connection cable, min. cross-section Length of supply lead (supplied) convertible S 4. Standard voltage (as supplied) Frequency Rated load Fuse rating Connection cable, min. cross-section Length of supply lead (supplied) V Hz kW A mm² mm 1N AC 230 50 2,85 1 × 16 4 × 1.5 2000 convertible a j V Hz kW A mm² mm 3 AC 230 50 5.5 3 × 20 4 × 2.5 2000 Alternative voltage Frequency Rated load Fuse rating Connection cable, min. cross-section Length of supply lead (not supplied) N 6. Standard voltage (as supplied) Frequency Rated load Fuse rating Connection cable, min. cross-section Length of supply lead with plug (supplied) V Hz kW A mm² mm 1N AC 230 50 3.2 1 × 16 3 × 1.5 2000 W 7. Standard voltage (as supplied) Frequency Rated load Fuse rating Connection cable, min. cross-section Length of supply lead with plug (supplied) V Hz kW A mm² mm 1N AC 230 - 240 50 5.5 – 6.0 1 × 25 3 × 2.5 2000 J 8. Standard voltage (as supplied) Frequency Rated load Fuse rating Connection cable, min. cross-section Length of supply lead with plug (supplied) V Hz kW A mm² mm 2 AC 200 50-60 3.75 2 × 20 3 × 2.75 2000 9. Standard voltage (as supplied) Frequency Rated load Fuse rating Connection cable, min. cross-section Length of supply lead (supplied) V Hz kW A mm² mm 2 AC 208 60 3.95 2 × 20 4 AWG 10 2000 U l Non-standard voltages: OS 230 1. Standard voltage (as supplied) Frequency Rated load Fuse rating Connection cable, min. cross-section Length of supply lead (supplied) V Hz kW A mm² mm 3 AC 230 60 4.4 3 × 16 4 × 1.5 2000 OS 400 2. Standard voltage (as supplied) Frequency Rated load Fuse rating Connection cable, min. cross-section Length of supply lead (supplied) V Hz kW A mm² mm 3 AC 400 50 4.2 3 × 16 4 × 1.5 2000 Installationsplan PW 6055/PW 6065 AV/LP EL Stand: 02.05.2005 Seite 9 OS 440 3. Standard voltage (as supplied) Frequency Rated load Fuse rating Connection cable, min. cross-section Length of supply lead (supplied) V Hz kW A mm² mm 3 AC 440 60 5.05 3 × 16 4 × 1.5 2000 kPa kPa l/min Inch mm 100 1000 10 (11) ¾" external thread 1500 l/h approx. 36 °C kPa kPa l/min Inch mm 70 100 1000 11 ¾" external thread 1500 l/h approx. 13 kPa kPa l/min Inch mm 100 1000 11 ¾" external thread 1500 Water requirements (average for 60°C programme) Standard connection [with hot water connection] PW 6055 (PW 6065) l/h approx. 14 When using an alternative water supply, the following volumes can be deducted from hot or cold water supplies: Deduction from cold water requirements PW 6055 Deduction from hot water requirements PW 6055 l/h l/h approx. 4 approx. 10 Max. temperature Machine drain connection (dext × s × l) [DN 70] On-site drain connection (dint × s × l) [DN 70 sleeve] Max. transient throughput °C mm mm l/min 70 75 × 1.9 × 40 75 × 1.9 × 50 50 Plug and socket connection in accordance with IEC 60309 recommended to facilitate electrical safety tests. Install mains isolator according to IEC 60947 on hard-wired connection. Wall socket or mains isolator must be accessible after installation. The use of an earth leakage circuit breaker (ELCB) is strongly recommended. If an ELCB is fitted, it must be a Type B RCD able to cope with rectified three-phase supplies. If necessary, equipotential bonding with good galvanic contact must be provided in accordance with all appropriate national and local regulations. Cold water Min. flow pressure Max. pressure Max. throughput (if hot water supply is not available) On-site connection thread according to DIN 44 991 Length of connection hose (parts supplied: 1 connection hose) Water requirements (average for 60°C programme) Standard connection [with hot water connection] PW 6055 (PW 6065) Additional requirements if hot water supply is not available. Hot water Max. temperature Min. flow pressure Max. pressure Max. throughput On-site connection thread according to DIN 44 991 Length of connection hose (parts supplied: 1 connection hose) Water requirements (average for 60°C programme) Standard connection [with hot water connection] PW 6055 (PW 6065) In absence of hot water, use blind stopper supplied and reprogramme controls to cold water intake. Alternative water supply (Optional) Drainage via dump valve Min. flow pressure Max. pressure Max. throughput (if hot water supply is not available) On-site connection thread according to DIN 44 991 Length of connection hose (parts supplied: 1 connection hose) Vented drainage required. If ventilation is insufficient, fit Miele kit, Mat. no. 05238090. Drain manifolds serving several machines must be of sufficient cross-section. Installationsplan PW 6055/PW 6065 AV/LP EL Stand: 02.05.2005 Seite 10 Drainage via drain pump Max. temperature Drain hose (Int. dia. × wall thickness × l) [DN 22] Hose sleeve for drain hose to be provided on site (ext. dia. x l) Max. transient throughput Max. head height (measured from base of unit) °C mm mm l/min mm 70 22 × 6 × 1500 22 × 30 26 1000 Fittings (supplied) Miele plinth UG/UO 5005 4 × metal angled brackets (to secure machine to plinth) 4 × screws DIN 571 (Ø × length) 4 × rawl plugs (Ø × length) Machine must be secured if installation is on plinth! Fixing materials for floating screed floor to be provided on site mm mm 8 × 65 12 × 60 On concrete platform 2 × metal brackets 2 × screws DIN 571 (Ø × length) 2 × rawl plugs (Ø × length) Machine must be secured if installation is on plinth! Fixing materials for floating screed floor to be provided on site mm mm 6 × 50 8 × 40 mm mm mm mm mm kg N N N Hz W 595 700 850 600 × 1000 1100 104 (105) 2820 1380 1455 1365 24 250 Vented drainage required. If ventilation is insufficient, fit Miele kit, Mat. no. 05238090. Drain manifolds serving several machines must be of sufficient cross-section. Payment system Possible extensions Machine data The following extensions are possible: Installation of payment system Installation as washer-dryer stack Liquid dispensing Connection to serial interface, RS 232 Width Depth Height Knocked-down dimensions (W × H) Minimum rear wall gap (measured to front of machine) Net weight PW 6055 (PW 6065) Dynamic floor load, max. Max. static load PW 6055 (PW 6065) Dynamic load, max. Drum frequency, max. Average heat dissipation (dependent on ambient room temperature and programme selected) Installation should only be carried out by authorised fitters in accordance with valid regulations! Observe installation instructions when installing machine! All rights reserved! Measurements in mm Installationsplan PW 6055/PW 6065 AV/LP EL Stand: 02.05.2005 Seite 11
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 5.0 (Windows) Create Date : 2005:07:06 07:29:01Z Modify Date : 2011:05:04 10:53:33-04:00 Metadata Date : 2011:05:04 10:53:33-04:00 Creator Tool : PScript5.dll Version 5.2 Format : application/pdf Creator : thage Title : Microsoft Word - Deckblatt PW 6055 + 6065_Elektro_GB.doc Document ID : uuid:7fb58fcf-c62b-4bb4-9e12-f0eb31ca3711 Instance ID : uuid:ce8c0108-ff1c-418f-b359-f1a4df84f214 Has XFA : No Page Count : 11 Author : thageEXIF Metadata provided by EXIF.tools