Miele Little Giant Pw 6065 Specification Sheet Deckblatt 6055 + 6065_Elektro_GB
2015-06-11
: Miele Miele-Little-Giant-Pw-6065-Specification-Sheet-748606 miele-little-giant-pw-6065-specification-sheet-748606 miele pdf
Open the PDF directly: View PDF .
Page Count: 11
Installationsplan / Installation plan
Installatietekening
Plan d`installation
Piano di installazione
Plano de instalación
Plano de instalação
Σχέδιο εγκατάστασης
Asennusohje
Installasjonsplan
Installationsplan G
PW 6055 + PW 6065 AV/LP
Materialnummer / Mat. no.: 06 664 230
Änderungsstand / Version: 00
Datum Zeichnung / Drawing date: 25.04.2005
Datum Legende / Legend date: 02.05.2005
Installationsplan PW 6055/PW 6065 AV/LP EL
Stand: 02.05.2005 Seite 8
Technical datasheet
Washer-extractor
Heating:
PW 6055/PW 6065 AV/LP
Electric (EL)
Legend:
Circled, bold-type abbreviations:
Connection required
Abbreviations surrounded by broken circle:
Connection optional or required, depending on model
G
Optional extras:
UG/UO 5005 Miele plinth
(UG = Box plinth/UO = Open plinth)
UM
Height Model mm 300
Width UG (UO) mm 609 (598)
Depth UG (UO) mm 622 (615)
Concrete platform Concrete platform optional (Min. quality B15)
Recommended height mm 300
BS
Minimum height mm 70
Recommended width mm 600
Recommended depth mm 650
Ensure good anchorage!
Machine connections:
1. Standard voltage (as supplied) V 2N AC 400 Electrical
connection Frequency Hz 50
Rated load kW 5.5
Fuse rating A 2 × 16
Connection cable, min. cross-section mm² 4 × 1.5
Length of supply lead (supplied) mm 2000
Alternative voltage V 1N AC 230
Frequency Hz 50
Rated load kW 2.85
Fuse rating A 1 × 16
Connection cable, min. cross-section mm² 3 × 1.5
Length of supply lead (supplied)
convertible
mm 2000
Country variations:
2. Standard voltage (as supplied) V 2N AC 400
Frequency Hz 50
G
Rated load kW 5.5
Fuse rating A 2 × 13
Connection cable, min. cross-section mm² 4 × 1.5
Length of supply lead (supplied) mm 2000
Alternative voltage V 1N AC 230
Frequency Hz 50
Rated load kW 2.85
Fuse rating A 1 × 13
Connection cable, min. cross-section mm² 3 × 1.5
Length of supply lead (supplied)
convertible
mm 2000
3. Standard voltage (as supplied) V 1N AC 230
Frequency Hz 50
Rated load kW 5.5
Fuse rating A 1 × 25
Connection cable, min. cross-section mm² 3 × 2.5
Length of supply lead with plug (supplied) mm 2000
Installationsplan PW 6055/PW 6065 AV/LP EL
Stand: 02.05.2005 Seite 9
4. Standard voltage (as supplied) V 3N AC 400
Frequency Hz 50
Rated load kW 4.8
Fuse rating A 3 × 10
a j
S Connection cable, min. cross-section mm² 5 × 1.5
Length of supply lead (supplied) mm 2000
5. Standard voltage (as supplied) V 2N AC 400
Frequency Hz 50
Rated load kW 5.5
Fuse rating A 2 × 16
B
Connection cable, min. cross-section mm² 4 × 1.5
Length of supply lead (supplied) mm 2000
Alternative voltage V 1N AC 230
Frequency Hz 50
Rated load kW 2,85
Fuse rating A 1 × 16
Connection cable, min. cross-section mm² 4 × 1.5
Length of supply lead (supplied)
convertible
mm 2000
Alternative voltage V 3 AC 230
Frequency Hz 50
Rated load kW 5.5
Fuse rating A 3 × 20
Connection cable, min. cross-section mm² 4 × 2.5
Length of supply lead (not supplied)
convertible
mm 2000
6. Standard voltage (as supplied) V 1N AC 230
Frequency Hz 50
Rated load kW 3.2
Fuse rating A 1 × 16
N
Connection cable, min. cross-section mm² 3 × 1.5
Length of supply lead with plug (supplied) mm 2000
7. Standard voltage (as supplied) V 1N AC 230 - 240
Frequency Hz 50
Rated load kW 5.5 – 6.0
Fuse rating A 1 × 25
W
Connection cable, min. cross-section mm² 3 × 2.5
Length of supply lead with plug (supplied) mm 2000
8. Standard voltage (as supplied) V 2 AC 200
Frequency Hz 50-60
Rated load kW 3.75
Fuse rating A 2 × 20
J
Connection cable, min. cross-section mm² 3 × 2.75
Length of supply lead with plug (supplied) mm 2000
9. Standard voltage (as supplied) V 2 AC 208
Frequency Hz 60
Rated load kW 3.95
Fuse rating A 2 × 20
U l
Connection cable, min. cross-section mm² 4 AWG 10
Length of supply lead (supplied) mm 2000
Non-standard voltages:
1. Standard voltage (as supplied) V 3 AC 230
Frequency Hz 60
Rated load kW 4.4
Fuse rating A 3 × 16
OS 230
Connection cable, min. cross-section mm² 4 × 1.5
Length of supply lead (supplied) mm 2000
2. Standard voltage (as supplied) V 3 AC 400
Frequency Hz 50
Rated load kW 4.2
Fuse rating A 3 × 16
OS 400
Connection cable, min. cross-section mm² 4 × 1.5
Length of supply lead (supplied) mm 2000
Installationsplan PW 6055/PW 6065 AV/LP EL
Stand: 02.05.2005 Seite 10
3. Standard voltage (as supplied) V 3 AC 440
Frequency Hz 60
Rated load kW 5.05
Fuse rating A 3 × 16
OS 440
Connection cable, min. cross-section mm² 4 × 1.5
Length of supply lead (supplied) mm 2000
Plug and socket connection in accordance with IEC 60309
recommended to facilitate electrical safety tests.
Install mains isolator according to IEC 60947 on hard-wired
connection.
Wall socket or mains isolator must be accessible after
installation.
The use of an earth leakage circuit breaker (ELCB) is strongly
recommended. If an ELCB is fitted, it must be a Type B RCD
able to cope with rectified three-phase supplies.
If necessary, equipotential bonding with good galvanic contact
must be provided in accordance with all appropriate national
and local regulations.
Min. flow pressure kPa 100
Max. pressure kPa 1000
Cold water
Max. throughput (if hot water supply is not available) l/min 10 (11)
On-site connection thread according to DIN 44 991 Inch ¾" external thread
Length of connection hose (parts supplied: 1 connection
hose)
mm 1500
Water requirements (average for 60°C programme)
Standard connection [with hot water connection]
PW 6055 (PW 6065) l/h approx. 36
Additional requirements if hot water supply is not available.
Max. temperature °C 70
Min. flow pressure kPa 100
Hot water
Max. pressure kPa 1000
Max. throughput l/min 11
On-site connection thread according to DIN 44 991 Inch ¾" external thread
Length of connection hose (parts supplied: 1 connection
hose)
mm 1500
Water requirements (average for 60°C programme)
Standard connection [with hot water connection]
PW 6055 (PW 6065) l/h approx. 13
In absence of hot water, use blind stopper supplied and
reprogramme controls to cold water intake.
Min. flow pressure kPa 100
Max. pressure kPa 1000
Max. throughput (if hot water supply is not available) l/min 11
Alternative water
supply
(Optional) On-site connection thread according to DIN 44 991 Inch ¾" external thread
Length of connection hose (parts supplied: 1 connection
hose)
mm 1500
Water requirements (average for 60°C programme)
Standard connection [with hot water connection]
PW 6055 (PW 6065) l/h approx. 14
When using an alternative water supply, the following
volumes can be deducted from hot or cold water supplies:
Deduction from cold water requirements PW 6055 l/h approx. 4
Deduction from hot water requirements PW 6055 l/h approx. 10
Max. temperature °C 70
Machine drain connection (dext × s × l) [DN 70] mm 75 × 1.9 × 40
On-site drain connection (dint × s × l) [DN 70 sleeve] mm 75 × 1.9 × 50
Drainage via
dump valve
Max. transient throughput l/min 50
Vented drainage required. If ventilation is insufficient, fit Miele
kit, Mat. no. 05238090.
Drain manifolds serving several machines must be of
sufficient cross-section.
Installationsplan PW 6055/PW 6065 AV/LP EL
Stand: 02.05.2005 Seite 11
Max. temperature °C 70
Drain hose (Int. dia. × wall thickness × l) [DN 22] mm 22 × 6 × 1500
Drainage via
drain pump
Hose sleeve for drain hose to be provided on site (ext. dia. x l) mm 22 × 30
Max. transient throughput l/min 26
Max. head height (measured from base of unit) mm 1000
Vented drainage required. If ventilation is insufficient, fit Miele
kit, Mat. no. 05238090.
Drain manifolds serving several machines must be of
sufficient cross-section.
Miele plinth UG/UO 5005
4 × metal angled brackets (to secure machine to plinth)
Fittings (supplied)
4 × screws DIN 571 (Ø × length) mm 8 × 65
4 × rawl plugs (Ø × length) mm 12 × 60
Machine must be secured if installation is on plinth!
Fixing materials for floating screed floor to be provided on site
On concrete platform
2 × metal brackets
2 × screws DIN 571 (Ø × length) mm 6 × 50
2 × rawl plugs (Ø × length) mm 8 × 40
Machine must be secured if installation is on plinth!
Fixing materials for floating screed floor to be provided on site
Payment system
The following extensions are possible:
Installation of payment system
Possible
extensions
Installation as washer-dryer stack
Liquid dispensing
Connection to serial interface, RS 232
Machine data Width mm 595
Depth mm 700
Height mm 850
Knocked-down dimensions (W × H) mm 600 × 1000
Minimum rear wall gap (measured to front of machine) mm 1100
Net weight PW 6055 (PW 6065) kg 104 (105)
Dynamic floor load, max. N 2820
Max. static load PW 6055 (PW 6065) N 1380 1455
Dynamic load, max. N 1365
Drum frequency, max. Hz 24
Average heat dissipation
(dependent on ambient room temperature and programme
selected)
W 250
Installation should only be carried out by authorised fitters in accordance with valid regulations!
Observe installation instructions when installing machine! All rights reserved! Measurements in mm