Mindray BIO Medical electronics WM1010BGN10 Cyberlink User Manual Cyberlink Wireless LAN Module datasheet

Shenzhen Mindray BIO-Medical electronics Co.,LTD. Cyberlink Cyberlink Wireless LAN Module datasheet

Users manual

                                                                                                        KF-XXXX-X-XXX-版本  No. Pin name  Type System  Description 1  SD_CLK    I  WLAN  SDIO Clock. 2  VIN    I  Common 3.3V Power supply input. 3  SD_CMD  I/O  WLAN  SDIO Command Line. 4  GND  I  Common Ground. 5  SD_D0  I/O  WLAN  SDIO Data Line 0. 6  /WL_RESET  I  WLAN  Low asserting reset for WLAN core.   7  SD_D1  I/O  WLAN  SDIO Data Line 1.   8  SLEEP_CLK  I  Common Low Power Clock input (32.768kHz). 9  SD_D2  I/O  WLAN  SDIO Data Line 2.   10 POW_ON  I  Common Used  by  PMU  to  decide  whether  or  not  to  power  down internal BCM4329 regulators. If POW_ON is low, then the regulators will be disabled. 11 /CD  O  Common Cyberlink On-line Detect. PIN tie to ground. 12 NC      No use 13 SD_D3  I/O  WLAN  SDIO Data Line 3.   14 VIN    I  Common 3.3V Power Input 15 LED  O  Common 3.3V Output 16 VIN    I  Common 3.3V Power Input 17 GND  I  Common Ground. 18 GND  I  Common Ground. 19 WL_WAKE_IN  I  WLAN  WLAN device wake-up signal input from host to WLAN.   20 BT_UART_TXD O  BT  Bluetooth UART serial output .Serial data output for the HCI UART interface.   21 NC      No use 22 BT_UART_RXD I  BT  Bluetooth UART serial input. Serial data input for the HCI UART interface. 23 NC      No use 24 BT_UART_RTS O  BT  Bluetooth  UART  request  to  send.  Active-low  request-to send signal for the HCI UART interface. 25 SW1  I  Common Antenna select. SW1 and SW2 are floating, Select antenna 1 SW1=1,SW2=0,Select antenna 1
                                                                                                        KF-XXXX-X-XXX-版本  SW1=0,SW2=1,Select antenna 2 26 BT_UART_CTS I  BT  Bluetooth  UART  clear  to  send.  Active-low  clear-to-send signal for the HCI UART interface. 27 SW2  I  Common Antenna select. SW1 and SW2 are floating, Select antenna 1 SW1=1,SW2=0,Select antenna 1 SW1=0,SW2=1,Select antenna 2 28 TYPE  O  Common Cyberlink type Detect. PIN tie to 3.3V. 29 GND  I  Common Ground. 30 VIN    I  Common 3.3V Power Input 31 /BT_RESET  I  BT  Low asserting reset for Bluetooth core.   32 BT_WAKE_IN  I  BT Bluetooth  device  wake-up  signal  input  from  host  to Bluetooth.  The  polarity  of  this  signal  is  software configurable and can be asserted high or low. 33 BT_WAKE_OUT O  BT  Host wake-up signal output from WLAN to host. 34 GND  I  Common Ground. 35 NC      Tie 10k to ground 36 WL_WAKE_OUT O  WLAN  Host wake-up signal output from WLAN to host.   37 BT_PCM_CLK  I/O  BT  PCM clock, can be master (output) or slave (input). 38 NC      Reserved for MIMO 39 BT_PCM_SYNC I/O  BT  PCM sync signal, can be master (output) or slave (input). 40 GND  I  Common Ground. 41 BT_PCM_OUT  I  BT  PCM data input. 42 NC      No use 43 BT_PCM_IN  O  BT  PCM data output. 44 NC      Reserved for MIMO 45 NC      No use 46 NC      Reserved for MIMO 47 NC      No use 48 NC      No use 49 WL_TXD  O  WLAN  TX pin of debug UART 50 NC      No use
                                                                                                        KF-XXXX-X-XXX-版本  51 WL_RXD  I  WLAN  RX pin of debug UART 52 NC      No use 1.7.2 Power On Sequence 1.7.2.1 Power On Sequence 1  Figure 2    Power On Sequence 1 1.7.2.2 Power On Sequence 2 Figure 3    Power On Sequence 2 1.7.2.3 Power On Sequence 3VINVINVINVIN    VINVINVINVIN
                                                                                                        KF-XXXX-X-XXX-版本  Figure 4    Power On Sequence 3 1.7.3 Interface 1.7.3.1 External Clock Reference (SLEEP_CLK) Table 7    External Clock Reference Parameter    Description  Remarks Nominal input frequency   32.768 KHz   Frequency accuracy  +/-200 ppm   Duty cycle  30-70 %   Input signal amplitude  200 to 1800 mVp-p  200-1800  mVp-p  to  avoid  additional current consumption. 3.3Vp-p maximum. Signal type  Square-wave or sine-wave   Input impedance  100KΩ;< 5 pF when power is applied or power is off  Clock  jitter  (integrated over 300Hz – 15kHz) <1 Hz   1.7.3.2 Input/Output DC Terminal Characteristics Table 8    Input/Output DC Terminal Characteristics Digital Terminals    Min  Typ  Max  Unit VIL input logic level low  -  -  0.8  V Input Voltage  VIH input logic level high  2.0  -  -  V VINVINVINVIN    VINVINVINVIN
                                                                                                        KF-XXXX-X-XXX-版本  VOL output logic level low (100μA load)  -  -  0.4  V Output Voltage  VOH output logic level high (-100μA load) 2.4  -  -  V IIL input logic level low  -  0.3  -  uA Input Current:  IIH input logic level high  -  0.3  -  uA IOL output logic level low (VOL =0.4V)  -  -  3.0  mA Output Current  IOH output logic level high (VOH =2.9V)  -  -  3.0  mA Input Capacitance :CIN  -  -  5  pF 1.7.3.3 WLAN SDIO Timing 1.7.3.3.1 Default Mode  Figure 5    WLAN SDIO Timing, Default Mode Table 9 WLAN SDIO Timing, Default Mode Parameter Symbol Min  Typ  Max  Unit Frequency-Data Transfer Mode fPP  0  -  25  MHz Frequency-Identification Mode  fOD  0  -  400-  KHz Clock Low Time  tWL  10  -  -  ns Clock High Time  tWH  10  -  -  ns Clock Rise Time    tTLH  -  -  10  ns Clock  CLK  (All values  are  referred to min. VIH and max. VIL) Min  (Vih)  =  0.7*VIN and  max  (Vil)  = 0.2*VIN Clock Falling Time    tTHL  -  -  10  ns Inputs:  CMD,  DAT  Input Setup Time    tISU  5  -  -  ns
                                                                                                        KF-XXXX-X-XXX-版本  (referenced to CLK)  Input Hold Time    tIH  5  -  -  ns Output  Delay  time-Data Transfer Mode   tODLY  -  -  14  ns Outputs:  CMD,  DAT (referenced to CLK) Output Delay time-Identification Mode   tODLY  -  -  50  ns   Remark: Timing is based on CL < 40pF load on CMD and Data. 1.7.3.3.2 High Speed Mode  Figure 6    WLAN SDIO Timing, High Speed Mode  Table 10 WLAN SDIO Timing, High Speed Mode Parameter Symbol Min  Typ  Max  Unit Frequency-Data Transfer Mode fPP  0  -  50  MHz Frequency-Identification Mode  fOD  0  -  400-  KHz Clock Low Time  tWL  7  -  -  ns Clock High Time  tWH  7  -  -  ns Clock Rise Time    tTLH  -  -  3  ns Clock  CLK  (All values  are  referred to min. VIH and max. VIL) Min  (Vih)  =  0.7*VIN and  max  (Vil)  = 0.2*VIN Clock Falling Time    tTHL  -  -  3  ns Input Setup Time    tISU  6  -  -  ns Inputs:  CMD,  DAT (referenced to CLK)  Input Hold Time    tIH  2  -  -  ns Outputs:  CMD,  DAT  Output  Delay  time-Data  tODLY  -  -  14  ns
                                                                                                        KF-XXXX-X-XXX-版本  Transfer Mode   Output Hold time    tOH  -  -  50  ns   (referenced to CLK) Total  System  Capacitance (each line) CL  -  -  40  pF Remark: Timing is based on CL < 40pF load on CMD and Data.  1.7.4 Mechanical This device complies with Industry Canada licence-exempt RSS standard(s).Operation is subject to the following two conditions: (1) this device may not causeinterference, and (2) this device must accept any interference, including interferencethat may cause undesired operation of the device.Le présent appareil est conforme aux CNR d'Industrie Canada applicables auxappareils radio exempts de licence. L'exploitation est autorisée aux deux conditionssuivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur del'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage estsusceptible d'en compromettre le fonctionnement.The distance between user and products should be no less than 20cmLa distance entre l'utilisateur et de produits ne devrait pas être inférieure à 20cmThe host device must be labelled to display the IC ID of the module "Contains IC:9726A-WM1010BGN10"
                                                                                                        KF-XXXX-X-XXX-版本 Appendix A FCC A.1 FCC statement in User's Manual (for class B) "Federal  Communications  Commission  (FCC)  Statement  This  Equipment  has  been  tested and found to comply with the limits for a class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment  generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to  radio  communications. However,  there  is no  guarantee  that  interference will not  occur in  a particular  installation. If this equipment does  cause harmful  interference to  radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  Reorient or relocate the receiving antenna.  Increase the separation between the equipment and receiver.  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  Consult the dealer or an experienced radio/TV technician for help. A.2 FCC Statements: 1.   This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:    This device may not cause harmful interference,    and This device must accept any interference received, including interference that may cause undesired operation. 2.   This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter. 3.   Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user authority to operate the equipment. 4.   This compliance to FCC radiation exposure limits for an uncontrolled environment, the minimum of 20 cm separation distance shall be maintained between antenna and body. The host device must be labelled to display the FCC ID of the module "ContainsFCC ID: ZLZWM1010BGN10"

Navigation menu