MITSUBISHI HOME REFRIGERATORS 2005 SERVICE MANUAL NO.SM-RE-0502 Models MR-385R-W-A MR-385R-ST-A MR-420R-W-A MR-420R-ST-A MR-455R-W-A MR-455R-ST-A MR-385R-W-A(NZ) MR-385R-ST-A(NZ) MR-420R-W-A(NZ) MR-420R-ST-A(NZ) MR-455R-W-A(NZ) MR-455R-ST-A(NZ) CONTENTS A……......Australia A(NZ) .....New Zealand 1. SPECIFICATIONS.................................................... 2. OUTLINES AND DIMENSIONS.................................. 3. WIRING DIAGRAM.................................................... 4. REFRIGERANT CIRCUIT........................................... 5. NAME OF THE PARTS........................................... 6. TROUBLE SHOOTING.............................................. 6.1 TROUBLE CRITERION OF MAIN PARTS....... 6.2 HOW TO CHECK P.C.BOARDS...................... 6.3 TEST POINT DIAGRAM OF MAIN CONTROL BOARD.............................. 6.4 MULFUNCTION DISPLAY AND CHECKING POINT........................................................... 6.5 IMPORTANCE DETAIL OF FAULT ANALYSIS. 7. DISASSEMBLY INSTRUCTIONS................................. 8. PARTS LIST............................................................... 1 7 10 11 13 14 14 16 17 18 19 20 23 1 SPECIFICATION 1.1 SPECIFICATION MR-385R-A MR-385R-A(NZ) Power supply Total capacity (Gross (AS)) Dimensions (HXWXD) Cabinet Food liner Cabinet Insulation Freezer door Refrigerator door Cooling system Freezer Refrigerator Evaporator Condenser Defrost system Drain Temperature control system Refrigerator room light Ice tray Ice box Freezer pocket Slide chilled case 230/240V 50Hz 385 (F : 130 R : 255) 1591 x 685 x 700 Acrylic resin coated steel ABS resin Foamed cyclopenthane Foamed cyclopenthane Foamed cyclopenthane Forced air convection Surround cooling,multi air flow,front air flow Fin and tube type Concealed type Automatic (Heater defrost) Automatic (drainage) Automatic control 240V 15W (E12) 1 pc. 1 pc. 2 pcs. 1 pc. 1 pc. 3 pcs. 1 pc. 2 pcs. 2 pcs. 2 pcs. 1 pc. 1 pc. 1 pc. 1 pc. 65 72 L mm. Crystal shelf (F) Crystal shelf (R) Accessories Weight Free pocket Egg rack Adjust pocket Bottle pocket Vegetable case Tray V Drain pan Bottle stopper Unit Shipping kg kg -1- MR-420R-A MR-420R-A(NZ) Power supply Total capacity (Gross (AS)) Dimensions (HXWXD) Cabinet Food liner Cabinet Insulation Freezer door Refrigerator door Cooling system Freezer Refrigerator Evaporator Condenser Defrost system Drain Temperature control system Refrigerator room light Ice tray Ice box Freezer pocket Slide chilled case 230/240V 50Hz 420 (F : 130 R : 290) 1696 x 685 x 700 Acrylic resin coated steel ABS resin Foamed cyclopenthane Foamed cyclopenthane Foamed cyclopenthane Forced air convection Surround cooling,multi air flow,front air flow Fin and tube type Concealed type Automatic (Heater defrost) Automatic (drainage) Automatic control 240V 15W (E12) 1 pc. 1 pc. 2 pcs. 1 pc. 1 pc. 3 pcs. 1 pc. 2 pcs. 2 pcs. 2 pcs. 1 pc. 1 pc. 1 pc. 1 pc. 69 73 L mm. Crystal shelf (F) Crystal shelf (R) Accessories Weight Free pocket Egg rack Adjust pocket Bottle pocket Vegetable case Tray V Drain pan Bottle stopper Unit Shipping kg kg -2- MR-455R-A MR-455R-A(NZ) Power supply Total capacity (Gross (AS)) Dimensions (HXWXD) Cabinet Food liner Cabinet Insulation Freezer door Refrigerator door Cooling system Freezer Refrigerator Evaporator Condenser Defrost system Drain Temperature control system Refrigerator room light Ice tray Ice box Freezer pocket Slide chilled case 230/240V 50Hz 454 (F : 130 R : 324) 1806 x 685 x 700 Acrylic resin coated steel ABS resin Foamed cyclopenthane Foamed cyclopenthane Foamed cyclopenthane Forced air convection Surround cooling,multi air flow,front air flow Fin and tube type Concealed type Automatic (Heater defrost) Automatic (drainage) Automatic control 240V 15W (E12) 2 pcs. 1 pc. 2 pcs. 1 pc. 1 pc. 4 pcs. 1 pc. 2 pcs. 3 pcs. 2 pcs. 1 pc. 1 pc. 1 pc. 1 pc. 73 79 L mm. Crystal shelf (F) Crystal shelf (R) Accessories Weight Free pocket Egg rack Adjust pocket Bottle pocket Vegetable case Tray V Drain pan Bottle stopper Unit Shipping kg kg -3- 1.2 ELECTRICAL PARTS SPECIFICATION MR-385R-A MR-385R-A(NZ) DG57C96RAW5 220/240V 50Hz Model Power supply Compressor Rated input W 106/108(220/240V 50Hz) Starting current A 7.38/8.01(220/240V 50Hz) Running current A 0.57/0.55(220/240V 50Hz) Winding resistance (T : 20 oC) 18.2 Ω(Main) / 17.7 Ω(Aux) PTH7M330MD2 PTC RELAY 5TM181NHBYY Model Motor protector o Ambient temperature Time C Sec. Current A 25 16 MAX 5.4 4µF 400VAC Running capacitor 1.8 X ∅ 0.7 X 2350 Capillary tube mm. Dehydrant Molecular sieve g 10 Refrigerant HFC. 134a g 145 ∅ Control board Defrosting control Defrosting timer Heater Defrost finish o C Thermister 14 + 1.5 Thermal fuse o C 73 384 Ω (240V 150W) Defrost heater Filter UDVH15MA1H Single phase Deodorition Model Type Fan motor 2p Number of poles Less than 10.2/12 (220/240V 50Hz) Input W Revolution r.p.m Model Dial position Temperature control Warmer Normal Colder 2520 + 200 / 2580+200 (220/240V 50Hz) Freezer o o o Refrigerator (MM1-6177) C ON -13.7 OFF -19.0 OPEN - SHUT 3.5 C -16.9 -22.9 MAX 5.0 -1.0 + 1.5 C -20.4 -27.5 - -12.5 -4- MR-420R-A MR-420R-A(NZ) DG66C11RAW5 220/240V 50Hz Model Power supply Compressor Rated input W 117/118(220/240V 50Hz) Starting current A 8.05/8.83(220/240V 50Hz) Running current A 0.71/0.66(220/240V 50Hz) Winding resistance (T : 20 oC) 15.4 Ω(Main) / 17.7 Ω(Aux) PTH7M330MD2 PTC RELAY 5TM205NHBYY Model Motor protector o Ambient temperature Time C Sec. Current A 25 16 MAX 6.0 4µF 400VAC Running capacitor 1.8 X ∅ 0.7 X 2350 Capillary tube mm. Dehydrant Molecular sieve g 10 Refrigerant HFC. 134a g 145 ∅ Control board Defrosting control Defrosting timer Heater Defrost finish o C Thermister 14 + 1.5 Thermal fuse o C 73 384 Ω (240V 150W) Defrost heater Filter UDVH15MA1H Single phase Deodorition Model Type Fan motor 2p Number of poles Less than 10.2/12 (220/240V 50Hz) Input W Revolution r.p.m Model Dial position Temperature control Warmer Normal Colder 2520 + 200 / 2580+200 (220/240V 50Hz) Freezer o o o Refrigerator (MM1-6177) C ON -13.7 OFF -19.0 OPEN - SHUT 3.5 C -16.9 -22.9 MAX 5.0 -1.0 + 1.5 C -20.4 -27.5 - -12.5 -5- MR-455R-A MR-455R-A(NZ) DD66C13RAW5 220/240V 50Hz Model Power supply Compressor Rated input W 127/131(220/240V 50Hz) Starting current A 8.3/9.1(220/240V 50Hz) Running current A 0.63/0.61(220/240V 50Hz) Winding resistance (T : 20 oC) 12 Ω(Main) / 28.7 Ω(Aux) PTH7M330MD2 PTC RELAY 5TM205NHBYY Model Motor protector o Ambient temperature Time C Sec. Current A 25 16 MAX 6.0 4µF 400VAC Running capacitor 1.8 X ∅ 0.7 X 2350 Capillary tube mm. Dehydrant Molecular sieve g 10 Refrigerant HFC. 134a g 145 ∅ Control board Defrosting control Defrosting timer Heater Defrost finish o C Thermister 14 + 1.5 Thermal fuse o C 73 384 Ω (240V, 150W) Defrost heater Filter UDVH15MA1H Single phase Deodorition Model Type Fan motor 2p Number of poles Less than 10.2/12 (220/240V 50Hz) Input W Revolution r.p.m Model Dial position Temperature control Warmer Normal Colder 2520 + 200 / 2580+200 (220/240V 50Hz) Freezer o o o Refrigerator (MM1-6177) C ON -13.7 OFF -19.0 OPEN - SHUT 3.5 C -16.9 -22.9 MAX 5.0 -1.0 + 1.5 C -20.4 -27.5 - -12.5 -6- OUTLINES AND DIMENSIONS 1591 8 568 942 1950 PLUG CORD LENGTH REQUIRED SPACE FOR INSTALLATION 40 685 20 1334 100 20 1591 MR-385R-A MR-385R-A(NZ) Unit : mm 685 73 2 454 700 -7- 1696 8 568 1047 73 1950 PLUG CORD LENGTH REQUIRED SPACE FOR INSTALLATION 40 685 20 1334 100 20 1696 MR-420R-A MR-420R-A(NZ) Unit : mm 685 700 -8- 454 1157 1806 8 568 685 73 1950 PLUG CORD LENGTH REQUIRED SPACE FOR INSTALLATION 40 685 20 1334 100 20 1806 MR-455R-A MR-455R-A(NZ) Unit : mm 700 -9- 454 3 WIRING DIAGRAM MR-385R-A MR-385R-A(NZ) MR-420R-A MR-420R-A(NZ) MR-455R-A MR-455R-A(NZ) (SKELETON WIRING DIAGRAM) (ACTUAL WIRING DIAGRAM) - 10 - 4 REFRIGERANT CIRCUIT MR-385R-A MR-420R-A MR-385R-A(NZ) MR-420R-A(NZ) - 11 - MR-455R-A MR-455R-A(NZ) - 12 - 5 NAME OF PARTS MR-385R-A MR-385R-A(NZ) MR-420R-A MR-420R-A(NZ) MR-455R-A MR-455R-A(NZ) - 13 - 6 TROUBLE SHOOTING 6.1 TROUBLE CRITERION OF MAIN PARTS MR-385R-A MR-385R-A(NZ) MR-420R-A MR-455R-A MR-420R-A(NZ) MR-455R-A(NZ) Components/ Part Name Parts Mounted Position Check Method and Criterion Compressor Model Rated input Starting current Running current MR-385R MR-420R,455R Compressor in DG57C96RAW5 DG66C11RAW5 the machine W 106/108(220/240V 50Hz) 117/118(220/240V 50Hz) chamber at the A 7.38/8.01(220/240V 50Hz) 8.05/8.83(220/240V 50Hz) A 0.57/0.55(220/240V 50Hz) 0.71/0.66(220/240V 50Hz) rear side of the frame Abnormal (faulty) Normal Auxilialy wiring MR-385R MR-420R,455R Main wiring 18.2 Ω (Approx.) 15.4 Ω (Approx.) Auxilliary wiring 17.7 Ω (Approx.) 17.7 Ω (Approx.) Opened(∞ Ω ) RU Short (0Ω) Main wiring Measure the resistance with a tester. o o (Ambient temperature:Room temperature 15 C ~ 25 C) In the control Run capacitor 400VAC Rated input panel of the Measure the resistance with a tester. abnormal(faulty) Short (0Ω ) Normal Opened (∞Ω ) Motor Model protector Connected Point Open Close refrigerator compartment MR-385R MR-420R,455R Compressor in 5TM181NHBYY 5TM205NHBYY the machine o chamber at the o 120 + 5 C 120 + 5 C o o 69 + 9 C 69 + 9 C o o Measure the resistance with a tester.(Ambient temperature:Room temperature 15 C ~ 25 C) PTC RELAY 5 2 6 3 2 abnormal(faulty) Less than 1Ω Opened (∞Ω ) Compressor in Model PTH7M330MD2 Measure the resistance with a tester. o o (Ambient temperature:Room temperature 15 C ~ 25 C) 3 6 Normal 5 rear side of the frame Normal abnormal(faulty) 33 Ω (Approx.) Opened (∞Ω ) or Short (0Ω) As PTC Relay has been heated while refrigerator is running be sure to measure the resistance after the thermistor has got cool enough. - 14 - the machine chamber at the rear side of the frame Components/ Part Name Check Method and Criterion Parts Mounted Position Fan grill of the freezer compartment. UDVH15MA1H Model Measure the resistance with a tester. Refrigerator fan motor (Ambient temperature:Room temperature 15oC ~ 25oC) Normal abnormal(faulty) 560+ 10% ( Ω ) Short (0Ω) Rated input 150 W operation method Power ON after defrosting o (14 + 1.5 C or more) Measure the resistance with a tester. Defrost Heater (Ambient temperature:Room temperature 15oC ~ 25oC) Normal Abnormal (faulty) 384Ω (Approx.) Opened ( ∞ Ω ) Resistance measured under the ambient temperature from 2. Out of the above range ............abnormal against temperature 30 25 Resistance 1. 200" to 500k" ............normal Defrost thermistors radiator of the freezer compartment. F-thermistor, control panel of the refrigerator compartment. Thermistor resistance (kΩ) -50: to +50: Thermistor In the drip tray under the evaporator of the freezer compartment Thermistor Check Procedure 20 15 10 Thermistor resistance will vary with the change of temperature. 5 -20 -10 Take the temperature around the thermistor, 0 10 20 o 30 ( C) Temperature and then measure resistance using a tester. The relation of resistance and temperature is as shown on the above graph. - 15 - 6.2 HOW TO CHECK P.C BOARDS MR-385R-A MR-420R-A MR-455R-A MR-385R-A(NZ) MR-420R-A(NZ) MR-455R-A(NZ) (1) Precautions Unplug unit before checking If the controller P.C. board box is opened with the refrigerator inside cooled, dew will form on the control board, causing trouble such as poor insulation. The following cares must be taken when servicing. 1. Be sure to unplug the power cord before servicing. 2. Wipe away droplets on the control board box with dry cloth, and dry it up before setting a new controller P.C board. (2) How to check the controller P.C board and vicinity. The control board box can be checked without opening the box. Measure the voltage and resistance using 8 connectors outside the box. How to check with connectors 1. Check for 230/240V output during power on. POWER ON Make the pin No.7,9 of the 9 pins white connector as a common pin, and measure the voltage between the common pin and another pin. Make sure that 230/240V is output Note: The room light always has 230/240V. 2. Check for "thermistor" output during power on. 5 pins white connector Make the pin No.1 of the 5 pin white connector as a common pin, and measure the voltage between the common pin and another pin. Make sure that 2-3 VDC is output. POWER OFF 3.Check for weak current wiring during power off 5 pins white connector Remove the connector, and measure the resistance across -No.1 pin and No.2 pin to confirm the continuity for DEF thermistor. -No.1 pin and No.3 pin to confirm the continuity for the Freezer thermistor. - 16 - 6.3 TEST POINT DIAGRAM OF MAIN CONTROL BOARD MR-385R-A MR-420R-A MR-455R-A MR-385R-A(NZ) MR-420R-A(NZ) MR-455R-A(NZ) - 17 - - 18 - LED display self - check Cycle 5 Sec. 1 time 2 times Cycle 5 Sec. 1 time 2 times 3 times Fault trouble of defrost heater 2 times Fault trouble of defrost thermistor 1 time Fault trouble of freezer thermistor 5 Sec. Defrost unfinished with in 2 hours 2. The consider short circuit or open circuit of thermistor , resistance of open circuit is ∞ Ω Change part 3. Check the resistance of temp. fuse , resistance of short circuit is 0 Ω Change part Improve in contact 2. Check the resistance of defrost heater 1. Check connector of control PCB CN1 , relay connector temp. fuse Change part Improve in contact 3 2 Priority Repairing 1. Check connector of control PCB CN5 , Open circuit or short relay connector 2 pin circuit case 2. Check the resistance of thermistor Corrective Cycle 1 time 2 times 1 Cycle 5 Sec. 1. Check connector of control PCB CN5 , relay Improve in contact Open circuit or short connector 6 pin circuit case 2. Check the resistance of thermistor Change part Caution 1. Before plug in the AC power , Be ensure the comp had been off more than 20 min. Malfunction display 6.4.3 ) Repairing and check point * A the case below , if the analysis result has malfunction over 2 points and will express in the list has more importance. Function display Cause Analysis result Check point OFF ON 1 time 2 times 6.4.1 ) Malfunction display will use LED for show self-check 6.4.2 ) Fucntion display 6.4 Malfunction Display and Checking points. Lighting mode 6.5 Importance detail of fault analysis 6.5.1 Flow chart of self - check 1) Self - check monitor circuit For show the fault condition of refrigerator and clarify point. Therefore, self - check monitor control is provided that are able to monitor No. of blinking condition with electric circuit and electric part . Before disconnect power plug please confirm LED self - check . "CONTROL PANEL" Refrigerator plug No connect? Yes Connect power plug LED show shelf - check Self - check No Mal Function Display (No .of blinking) Yes Check the fault point as malfunction list Disconnect power plug No change on display Normal operation Caution 1. As the part list below couldn't analysis by self - check , then please check by reference to trouble shooting page. - Dilapidation of door switch ,refrigerator room and freezer room. - Dilapidation of compressor and fan motor . 2. If have malfunction when supply the power . Compressor and fan motor will not operate 20 minutes. Repair the macfunction cause Connect power plug 2) Interval of self check analysis - Troubles of thermistor : will check always. - Trouble of defrost heater : will just analyse during defrost display only. (The period checking will analyse the defrost circuit after connect the plug 2 hours ) - 19 - 7 DISASSEMBLY INSTRUCTIONS MR-385R-A MR-420R-A MR-455R-A MR-385R-A(NZ) MR-420R-A(NZ) MR-455R-A(NZ) Unplug the power cord before prepairing and servicing OPERATION PROCEDURE PHOTO Photo 1 1. Remove parts insider the Freezer room (1) Photo 1st Remove Crystal shelf Freezer, Ice corner tray assy, Ice tray, Ice box Crystal shelf F Ice tray Fan Grille (2) Photo 2nd Remove scews for closing Lead cover F, Remove 2 Rivets From Fan grille Ice corner tray assy Ice box Photo 2 Screw Rivets (3) Photo 3rd Cut binder, remove poly bag, Take off connector lead wire. Lead cover F Fan grille Fan motor (4) Photo 4th Remove Fan motor after remove fan and remove screw out of fan motor base. Photo 3 Bag Binder Defrost thermal fuse and Freezer thermistor (5) Photo 4th Remove fan grille out of bell mouth, remove the connector and plug to take out the thermal fuse and Photo 4 thermistor freezer. Defrost heater and Drip tray (6) Photo 5th Lift up evaporator and remove the defrost heater out of base after remove heater cover plate and drip tray Connector lead wire Screw Thermal fuse Fan motor Bell mouth Caution on assembly (7) 1. Insert the fan into the base of fan motor's shaft, check if the fan rotates with your finger. 2. When inserted drip tray to effect to slacken the lead wire of defrost heater in order to prevent water from entering the glass tube. 3. Attach defrost thermistor with muffler and lighten the binder. Photo 5 Evaporator Def thermistor Drip tray Defrost heater Heater cover - 20 - OPERATION PROCEDURE PHOTO Photo 6 2. Remove parts inside the refrigerator (1) Remove chilled case door and slide chilled case , Control panel remove crystal shelf of refrigerator room , remove the control panel Thermo dial R (Photo 6) (2) Remove lamp cover R Lamp cover R (Photo 6) (3) Remove screw and rivet , pull the control panel with to right refrigerator wall. (Photo 6) (4) Pick the aluminium tape and sealing tape, remove PC Board PC Board Photo 7 (Photo 7) Sealing tape (5) Remove duct R assy, damper thermo is installed within it. Aluminium tape (Photo 7) Remove the screw of damper thermo Caution on assembly 1. Be sure to use new sealing materials and tape for assembly. 2. Attach the sealing material of refcon assy and attach the aluminium tape everytimes for protective moisture. - 21 - Thermo dial F Rivets Screws Duct R assy OPERATING PROCEDURE 3. Removing the compressor (1) Detach the drain pan. Compressor (2) Collect gas from the charge pipe on the high pressure side. (3) After collecting gas, cut the charge pipe on the low pressure side. (4) Detach the welded section of the discharge pipe and suction pipe (5) Replace the compressor and the dryer at a time. (The dryer should be the one packed with the compressor.) CAUTION ON ASSEMBLY After replacement check cooling operation and check the weld for gas leaking. FigSuction pipe w w Binder Dryer Charge pipe U Washer w w : This mark shows welding point. - 22 - Discharge pipe (High pressure side) 8 PARTS LIST DOOR, BODY PARTS MR-385R-A MR-385R-A(NZ) MR-420R-A MR-420R-A(NZ) 7 8 1 11 2 3 4 9 5 10 6 MR-455R-A MR-455R-A(NZ) 7 8 1 11 2 3 4 9 10 5 6 - 23 - NO. PART NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 KIEJ62131 KIE401115 KIEJ62118 KIEJ62159 KIEJ62124 KIEH88143 KIEJ81001 KIEJ82001 KIEH79111 KIEJ81000 KIEJ82000 KIEJ83000 KIEJ84000 KIEJ85000 KIEJ86000 KIEH79110 KIEH82110 KIEH85110 KIEG05741 KIEJ81011 KIEJ82011 KIEJ81010 KIEJ82010 PART NAME SPEC FREEZER POCKET EGG RACK FREE POCKET ADJUST POCKET BOTTLE POCKET BOTTLE STOPPER DOOR F MAGNET GASKET ASSY (F) 385R A A(NZ) W ST W ST 2 2 2 2 2 2 2 2 1 1 1 1 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Q'TY/UNIT 420R A A(NZ) W ST W ST 2 2 2 2 2 2 2 2 1 1 1 1 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 DOOR R 455R PRICE A A(NZ) W ST W ST 2 2 2 2 2 2 2 2 1 1 1 1 3 3 3 3 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 MAGNET GASKET ASSY (R) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 CATCHER HANDLE COVER R HANDLE BODY KIEJ79031 BADGE ASSY 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 RECOMMEND PART NO. 7, 8, 9, 10 ABBREVIATION F FREEZER ROOM R REFRIGERATOR ROOM ENCIRCLED PART NUMBER ARE NOT SHOWN IN THE FIGURES. - 24 - ACCESSORY PARTS MR-385R-A MR-385R-A(NZ) MR-420R-A MR-420R-A(NZ) 16 17 18 1 2 3 19 20 21 22 4 23 24 5 6 7 8 9 10 11 12 13 14 15 25 26 27 22 28 31 29 MR-455R-A MR-455R-A(NZ) 16 30 17 18 19 20 21 22 1 2 3 4 5 6 7 8 9 10 23 24 25 26 11 12 13 14 27 22 28 31 15 29 - 25 - 30 Q'TY/UNIT NO. PART NO. PART NAME 1 2 3 4 KIEH79662 KIEJ81473 KIEH79663 KIEH79450 KIEH79665 KIEH82665 KIEH85665 KIEH79411 KIEJ81850 KIEH79305 KIEHK4305 KIEH79853 KIEH82853 KIEH85853 KIEJ62470 KIEJ65470 KIEH79420 KIEJ81468 KIEJ62405 KIEH79435 KIE805794 KIEH79326 KIEJ81705 KIEJ82705 KIEJ81701 KIEH79431 KIEH79440 KIEH79467 KIEB66746 KIEE94703 KIEJ62418 KIEH79416 KIEH79315 KIEH79474 KIEE94702 KIEH79795 KIEC02460 KIEJ81730 KIEJ82730 BELL MOUTH LAMP COVER (F) FAN GRILLE ICE CORNER ASSY 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 SPEC 455R 385R 420R PRICE A A(NZ) A A(NZ) A A(NZ) W ST W ST W ST W ST W ST W ST 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 DUCT R ASSY SLIDE CHILLED CASE CONTROL PANEL THERMO DIAL (R) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 CRYSTAL SHELF (R) TRAY V VEGETABLE CASE DRAIN PAN CASTER SET LEAD COVER F HINGE COVER HINGE ASSY (UPPER) CRYSTAL SHELF (F) ICE TRAY ICE BOX STOPPER HINGE HINGE ASSY (MIDDLE) CHILLED CASE DOOR TRAY C THERMO DIAL (F) VITAMIN GUARD HINGE ASSY (LOWER) CASTER ASSY ADJUST BOLT KICK PLATE 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3 1 1 1 2 1 1 1 1 1 1 2 1 1 1 1 1 1 2 2 1 1 3 1 1 1 2 1 1 1 1 1 1 2 1 1 1 1 1 1 2 2 1 1 3 1 1 1 2 1 1 1 1 1 1 2 1 1 1 1 1 1 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 4 1 1 1 2 1 1 1 4 1 1 1 2 1 1 4 1 1 1 2 1 1 1 4 1 1 1 2 1 1 CONTROL PANEL (SUB) LAMP COVER (R) 1 1 1 1 1 1 1 1 3 1 1 1 2 1 1 1 1 1 1 2 1 1 1 1 1 1 2 2 1 1 3 1 1 1 2 1 1 1 1 1 1 2 1 1 1 1 1 1 2 2 1 1 3 1 1 1 2 1 1 1 1 1 1 2 1 1 1 1 1 1 2 2 1 1 3 1 1 1 2 1 1 3 1 1 1 2 1 1 1 1 1 2 1 1 1 1 1 1 2 2 1 1 1 1 1 2 1 1 1 1 1 1 2 2 1 1 1 1 1 2 1 1 1 1 1 1 2 2 1 1 1 1 1 1 2 1 1 1 1 1 1 2 2 1 1 1 1 2 1 1 1 1 1 1 2 2 1 1 RECOMMEND PART NO. 2, 3, 4, 5, 6, 11, 13, 19, 20, 21, 24, 25 ABBREVIATION F FREEZER ROOM V BETWEEN REFRIGERATOR ROOM AND VEGETABLE ROOM R REFRIGERATOR ROOM - 26 - 1 1 1 1 1 2 1 1 1 1 1 1 2 2 1 ELECTRICIAL PARTS AND UNIT PARTS MR-385R-A MR-385R-A(NZ) MR-420R-A MR-420R-A(NZ) MR-455R-A MR-455R-A(NZ) 1 12 31 13 14 15 16 17 15 18 19 20 21 22 23 24 2 3 4 5 6 7 8 25 30 26 9 27 10 11 28 29 - 27 - Q'TY/UNIT NO. PART NO. 1 2 KIEH79336 THERMAL FUSE ( DEF ) KIEH85995 EVAPORATOR 3 KIEH79537 HEATER ROOF 4 KIEHM2392 DEFROST HEATER ASSY 5 KIEB66397 HEATER COVER 6 KIE402360 LAMP 7 KIEH79538 DRIP TRAY 8 KIEH79301 DAMPER THERMO 9 KIEJ81277 KIEJ82277 COMPRESSOR 455R 420R 385R PRICE A A(NZ) A(NZ) A A(NZ) W ST W ST W ST W ST W ST W ST SPEC PART NAME A 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 E17 240V I5W 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 DG57C96RAW5 1 1 1 1 1 1 1 1 1 1 1 1 240V, 150W NOT DEODORIZER MM1-6177 DG66C11RAW5 10 KIE902735 U WASHER 3 3 3 3 3 3 3 3 3 3 3 3 11 KIEE76797 RUBBER MOUNT 4 4 4 4 4 4 4 4 4 4 4 4 12 KIEH79312 THERMISTOR (DEF) 1 1 1 1 1 1 1 1 1 1 1 1 13 KIEH79378 THERMISTOR (F) 1 1 1 1 1 1 1 1 1 1 1 1 14 KIEH79323 MOTOR ATTACH 1 1 1 1 1 1 1 1 1 1 1 1 15 KIE401329 FAN MOTOR BUSH 2 2 2 2 2 2 2 2 2 2 2 2 16 KIEC02320 FAN MOTOR UDVH15MA1H 1 1 1 1 1 1 1 1 1 1 1 1 17 KIECD4362 FAN SWITCH 1 1 1 1 1 1 1 1 1 1 1 1 18 KIEHD2386 LAMP SOCKET(R) 1 1 1 1 1 1 1 1 1 1 1 1 19 KIEG01321 FAN 1 1 1 1 1 1 1 1 1 1 1 1 20 KIEA53346 RUNNING CAPACITOR 4 µF, 400VAC 1 1 1 1 1 1 1 1 1 1 1 1 21 KIEJ81339 REFCON ASSY 1 1 1 1 1 1 1 1 1 1 1 1 22 KIEH82336 THERMAL FUSE 1 1 1 1 1 1 1 1 1 1 1 1 23 KIEH79363 LAMP SWITCH ( R ) 1 1 1 1 1 1 1 1 1 1 1 1 24 KIEJ81354 PLUG CORD ASSY 1 1 1 1 1 1 1 1 1 1 1 1 25 KIEJ81807 CONNECTOR BOX 1 1 1 1 1 1 1 1 1 1 1 1 26 KIEAA1980 DRYER 1 1 1 1 1 1 1 1 1 1 1 1 27 KIEG05341 PROTECTOR COVER 1 1 1 1 1 1 1 1 1 1 1 1 5TM181NHBYY 1 1 1 1 1 1 1 1 1 1 1 1 28 KIEJ62340 KIEJ83340 MOTOR PROTECTOR 29 KIEE76330 PTC RELAY 30 31 4AXH-9,10GR 5TM205NHBYY PTH7MM330MD2 1 1 1 1 1 1 1 1 1 1 1 1 KIEH61399 FILTER 1 1 1 1 1 1 1 1 1 1 1 1 KIEHJ3311 THERMITOR (A.T.) 1 1 1 1 1 1 1 1 1 1 1 1 RECOMMEND PART NO. 1, 6, 9, 10, 13, 14, 22, 23, 27, 29, 30 ABBREVIATION F FREEZER ROOM R REFRIGERATOR ROOM DEF DEFROST - 28 - PACKING PART MR-385R-A MR-420R-A MR-455R-A MR-385R-A(NZ) MR-420R-A(NZ) MR-455R-A(NZ) 3 TOP CUSHION MID 1 2 NO STEP ON 3 8 C.F.B TOP COVER 1 C.F.B BOX ASSY R L 2 TOP CUSHION 5 SIDE CUSHION ASSY REFRIGERATOR 4 PACKING COVER 6 BOTTOM CUSHION 7 C.F.B PALLET - 29 - NO. PART NO. PART NAME KIEJ81970 SPEC Q'TY/UNIT 455R 385R 420R PRICE A A(NZ) A A(NZ) A(NZ) A W ST W ST W ST W ST W ST W ST 1 KIEJ82970 1 KIEJ83970 1 KIEJ84970 1 KIEJ85970 1 KIEJ86970 KIEJL4970 1 1 C.F.B BOX ASSY 1 KIEJL5970 1 KIEJL6970 1 KIEJL7970 1 KIEJL8970 1 KIEJL9970 2 3 4 5 6 7 8 KIEJ81979 KIEH79972 KIEG55973 KIEJ81971 KIEH79978 KIEH79974 KIEH79975 1 TOP CUSHION TOP CUSHION MID PACKING COVER SIDE CUSHION ASSY BOTTOM CUSHION C.F.B PALLET C.F.B TOP COVER 1 1 1 1 1 1 1 - 30 - 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 MITSUBISHI ELECTRIC CORPORATATION HEAD OFFICE : MITSUBISHI DENKI BLDG., MARUNOUCHI,TOKYO 100. TELEX : J24532 CABLE MELCO TOKYO Distributed by BLACK DIAMOND TECHNOLOGIES LIMITED (BDT) Wellington Office (Head Office) 1 Parliament Street PO Box 30-772 Lower Hutt Ph : (04) 560 9100 Fax : (04) 560 9133 Auckland Office Unit1, 4 Walls Road Penrose Auckland PO Box 12-726 Ph: (09) 526 9340 Fax : (09) 526 9369 Christchurch Office Suite 2, Level 1 37 Manderville Street Chistchurch PO Box 1604 Ph : (03) 341 7052 Fax : (03) 341 7054
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Create Date : 2005:07:04 23:02:56Z Modify Date : 2005:07:05 11:05:22+12:00 Page Count : 32 Creation Date : 2005:07:04 23:02:56Z Mod Date : 2005:07:05 11:05:22+12:00 Producer : Acrobat Distiller 5.0.5 (Windows) Author : dannyt Metadata Date : 2005:07:05 11:05:22+12:00 Creator : dannyt Title : MR-385R_420R_455R_A_A(NZ).pdfEXIF Metadata provided by EXIF.tools