Mitsubishi Electronics Msz Fa35Va Users Manual
MSZ-FA35VA to the manual 163b9e8f-ff35-4186-97e2-72bb48d65f3e
2015-02-09
: Mitsubishi-Electronics Mitsubishi-Electronics-Msz-Fa35Va-Users-Manual-556450 mitsubishi-electronics-msz-fa35va-users-manual-556450 mitsubishi-electronics pdf
Open the PDF directly: View PDF
Page Count: 40
![SERVICE MANUALCONTENTS1. TECHNICAL CHANGES ····································22. PART NAMES AND FUNCTIONS······················33. SPECIFICATION·················································54. NOISE CRITERIA CURVES·······························65. OUTLINES AND DIMENSIONS ·························76. WIRING DIAGRAM ············································87. REFRIGERANT SYSTEM DIAGRAM················88. SERVICE FUNCTIONS ······································99. TROUBLESHOOTING······································1110. DISASSEMBLY INSTRUCTIONS·····················3111. PARTS LIST······················································3512. OPTIONAL PARTS···········································38Wireless typeModelsMSZ-FA25VA - (WH)MSZ-FA35VA - (WH)E1E1No. OB371SPLIT-TYPE, HEAT PUMP AIR CONDITIONERSIndication of model nameMSZ-FA25VA -MSZ-FA35VA - E1E1NOTE:This service manual describes technical data of the indoor units.•As for outdoor units MUZ-FA25VA- , MUZ-FA35VA- , MUZ-FA25VAH- andMUZ-FA35VAH- , refer to service manual OB372.•As for outdoor units MXZ-3A54VA- , MXZ-4A71VA- and MXZ-4A80VA- ,refer to service manual OB377.E1E1E1E1E1E1E1OB371_--1qxp 05.1.17 12:50 Page 1](https://usermanual.wiki/Mitsubishi-Electronics/MitsubishiElectronicsMszFa35VaUsersManual556450.1947569682-User-Guide-Page-1.png)
![21TECHNICAL CHANGESMSZ-A09YV - ➔MSZ-FA25VA -MSZ-A12YV - ➔MSZ-FA35VA - E1E1E1E112. PLASMA DEODORIZING/AIR PURIFYING filter units have been added.13. i-see Sensor has been added.(i-see control operation and AREA setting have been added.)14. Air cleaning filer has been removed.15. Signal of remote controller has been changed. (It is not available for the conventional models.) 16. Symbol on terminal block has been changed (to S1/S2/S3). NOTE:Do not remove the vane motor from the motor unit.Do not disassemble the horizontal vane motor unit.11. Front panel driving motor unit which opens and closes the front panel has been added.Front panel opening/closing output gearNOTE: Do not disassemble the front panel driving motor unit.Generalized stepping motor10. The vertical vane motor unit has been added.An external gear is added to the generalized stepping motor. The unit is structured so that the driving torque and stopping torque would increase.Generalized stepping motorNOTE: Do not remove the vane motor from the motor unit.Do not disassemble the vertical vane motor unit.1. Indication of capacity has been changed.(BTU base ➔kW base)2. Controller method between indoor and outdoor has been changed.3. Power supply method has been changed (change to supply from outdoor unit).4. Power supply cord has been removed.5. Indoor electronic control P.C. board has been changed.6. Position of terminal block has been changed.7. Indoor fan motor has been changed. ( AC ➔DC)8. Indoor heat exchanger has been changed.9. The horizontal vane motor unit has been changed.An external gear is added to the generalized stepping motor. The unit is structured so that the driving torque and stopping torque would increase.OB371_--1qxp 05.1.17 12:50 Page 2](https://usermanual.wiki/Mitsubishi-Electronics/MitsubishiElectronicsMszFa35VaUsersManual556450.1947569682-User-Guide-Page-2.png)