Mobix Wireless Solutions 3000 DATA COLLECTION SYSTEM User Manual
Mobix Wireless Solutions LTD DATA COLLECTION SYSTEM Users Manual
Users Manual
n-DNet Data Concentrator Product model: C1000/2000/3000 Manual Version 1.0 May 2011 Mobix Wireless Solutions ltd. 88 Gisin St. Petah-Tikva, 7160 ISRAEL Tel. Fax Web E-mail +972-3-9213484 +972-3-9213482 www.mobix.com info@mobix.com Page 2 of 17 GENERAL .................................................................................................................................... 3 MAJOR COMPONENTS ............................................................................................................. 4 SPECIFICATIONS ....................................................................................................................... 6 CONNECTORS AND PERIPHERALS ....................................................................................... 7 GENERAL VIEW ..................................................................................................................................................................7 LIGHT EMITTED DIODES (LED) .........................................................................................................................................8 BB2 BOARD .......................................................................................................................................................................8 CONNECTORS.....................................................................................................................................................................9 JUMPERS CONFIGURATIONS .............................................................................................................................................10 INSTALLATION ........................................................................................................................ 11 MOUNTING: .....................................................................................................................................................................11 POWER:............................................................................................................................................................................11 LCD (DISPLAY): ..............................................................................................................................................................11 SAFTEY ...................................................................................................................................... 11 OPERATING: ............................................................................................................................. 12 TROUBLESHOOTING .............................................................................................................. 14 APPENDIX ................................................................................................................................. 16 88 Gisin St. Petach-Tikva 49170 Israel Tel: +972-3-9213484 Fax: +972-3-9213482 Mobix Wireless Solutions ltd. 88 Gisin St. Petah-Tikva, 7160 ISRAEL Tel. Fax Web E-mail +972-3-9213484 +972-3-9213482 www.mobix.com info@mobix.com Page 3 of 17 General The n-DNet™ Concentrator is a key component in managing segments of the Mobix patented n-Dimensional Network (see box for n-DNet™ description.) On one end, the Concentrator controls communications with a cluster of up to 1000 meters and on the other end it connects to the MDM Server. The Concentrator communicates with the meters over the simultaneous RF and PLC n-Dimensional mesh network. Mobix advanced n-DNet™ technology provides unprecedented advantages in data availability, solution topology and price/performance. Actual meter connectivity is achieved either by a meter embedded/connected n-DNet™ component or through a network node such as an n-DNet™ Hub. To connect to the MDM server, the Concentrator supports multiple IP based options such as wireless GPRS, LAN or Wi-Fi. 88 Gisin St. Petach-Tikva 49170 Israel Tel: +972-3-9213484 Fax: +972-3-9213482 Mobix Wireless Solutions ltd. 88 Gisin St. Petah-Tikva, 7160 ISRAEL Tel. Fax Web E-mail +972-3-9213484 +972-3-9213482 www.mobix.com info@mobix.com Page 4 of 17 Major Components The Concentrator has many major hardware components on board – altogether bring the power and flexibility to adapt it for almost any end system. Power supply o Smart protecting operational power supply unit. The hardware is equipped with power stabilizers and filters, protecting the board from hazardous input voltage levels and ensuring the operational power is steady and strong. o The PS unit is built to meet international safety and noise filtering standards. Internal Modem (incase of an upgrade) o The concentrator needs to communicate not just with the meters but also with the ‘outside world’ - it communicates with a remote server (Management) for receiving commands or sending information. o The concentrator has an internal GPRS modem for that cause. Secondary serial communication ports (RS232) o In addition to the serial port associated with the modem, the concentrator provides 2 second serial RS232 ports, allowing for connecting to an n-DNet NIC, PLC modem, RF transceiver, Bluetooth device or a direct serial connection to a meter. o An external serial connector is located on the concentrator box and used to connect a handheld reader for data download. RTC For providing an accurate time keeping even without external updates the concentrator includes an internal Real Time Clock mechanism. It is capable of keeping the time and date 88 Gisin St. Petach-Tikva 49170 Israel Tel: +972-3-9213484 Fax: +972-3-9213482 Mobix Wireless Solutions ltd. 88 Gisin St. Petah-Tikva, 7160 ISRAEL Tel. Fax Web E-mail +972-3-9213484 +972-3-9213482 www.mobix.com info@mobix.com for long periods without external power (in case of power shutdowns for example). LCD Memory o In addition to a large internal RAM, the concentrator is equipped with a 2MB flash memory for storing data. This memory is non-volatile and can store the data even without power. n-DNet NIC o The concentrator communicates with the n-DNet network using the internal n-DNet NIC. It provides simultaneous communication over both PLC (power line) and RF. The concentrator has a built in LCD for 240x128 dots display. 88 Gisin St. Petach-Tikva 49170 Israel Tel: +972-3-9213484 Fax: +972-3-9213482 Page 5 of 17 Mobix Wireless Solutions ltd. 88 Gisin St. Petah-Tikva, 7160 ISRAEL Tel. Fax Web E-mail +972-3-9213484 +972-3-9213482 www.mobix.com info@mobix.com Page 6 of 17 Specifications Input Voltage Power supply unit: internal circuit: Circuit operational voltage Current consumption RF PLC Enclosure Environmental 88 Gisin St. Petach-Tikva 49170 Israel 100-130VAC (47-440Hz) 9 – 30 VDC 5 VDC 200mA (Normal) 550mA – 1500mA (OEM modem attached) Interfaces External RS232 port (D-type 9-pin connector) Two 6 pin connectors (internal) for different operation modes (Prog, Normal, AVL, Modem). Software download through main RS232 port. 2 LEDs (internal). External 4x4 keypad. 915MHz 100-400KHz FCC, Cenelec and ARIB compatibility IP65 Length: 250 mm Width: 160 mm Height: 92 mm Operating temperature Range: -30º to +70ºC Humidity: 0% to 95% noncondensing For installation indoors or semi outdoors (protected by roof) Tel: +972-3-9213484 Fax: +972-3-9213482 Mobix Wireless Solutions ltd. 88 Gisin St. Petah-Tikva, 7160 ISRAEL Tel. Fax Web E-mail +972-3-9213484 +972-3-9213482 www.mobix.com info@mobix.com Page 7 of 17 Connectors and Peripherals General view LCD Keypad AC power input (3ph) Local communication port 88 Gisin St. Petach-Tikva 49170 Israel Tel: +972-3-9213484 Fax: +972-3-9213482 Mobix Wireless Solutions ltd. 88 Gisin St. Petah-Tikva, 7160 ISRAEL Tel. Fax Web E-mail +972-3-9213484 +972-3-9213482 www.mobix.com info@mobix.com Page 8 of 17 Light Emitted Diodes (LED) Two internal LED on the board provide useful visual information while running and maintaining the BB2. LED Legend: LED Top Bottom DEFINATION MCU Module State Power STATE ON - Normal OFF- NO Power BB2 board Power State Con 2 Con1 MCU State 88 Gisin St. Petach-Tikva 49170 Israel Tel: +972-3-9213484 Fax: +972-3-9213482 Mobix Wireless Solutions ltd. 88 Gisin St. Petah-Tikva, 7160 ISRAEL Tel. Fax Web E-mail Page 9 of 17 +972-3-9213484 +972-3-9213482 www.mobix.com info@mobix.com Connectors CONNECTOR POWER Inputs Con Con 1 DB9 Con 2 DB9 Pin # DEFINATION STANDARD VALUE 1,2 Top 2 Pins GND 9V-40V DC MAX Current 2.0A 3,4 Bottom 2 Pins 1-3 Input 1-3 0-5V 4-6 Input 4-6 0-5V 7-9 Output 7-9 0-5V 10 GND GND TX1 RS232 RX1 RS232 GND GND TX0 RS232 RX0 RS232 GND GND FUNCTION GND MCU + modem Power Dry Contact input Analog input Dry Contact output GND Programming comm. port Programming comm. port GND PLC/RF comm. port PLC/RF comm. port GND GND PWR Inputs Con Pin 1 88 Gisin St. Petach-Tikva 49170 Israel Tel: +972-3-9213484 Fax: +972-3-9213482 Mobix Wireless Solutions ltd. 88 Gisin St. Petah-Tikva, 7160 ISRAEL Tel. Fax Web E-mail +972-3-9213484 +972-3-9213482 www.mobix.com info@mobix.com Page 10 of 17 Jumpers configurations The BB2 (internal) PCB offers 4 jumpers (J1,J2,J3,J4) for different operations such as programming, communication, testing etc. In normal operation mode, the jumper configurations should be as follows: CPU mode jumpers: J1 J3 Communication port (CON2) jumpers: J2 J4 88 Gisin St. Petach-Tikva 49170 Israel Tel: +972-3-9213484 Fax: +972-3-9213482 Mobix Wireless Solutions ltd. 88 Gisin St. Petah-Tikva, 7160 ISRAEL Tel. Fax Web E-mail +972-3-9213484 +972-3-9213482 www.mobix.com info@mobix.com Page 11 of 17 Installation Mounting: The concentrator should be mounted on a wall or pole using at least two mounting points. The mounting is done using the supplied mounting plates, connected to the back of the concentrator box. Power: The required power supply is 85-265VAC (47-440Hz). The concentrator has an internal connector for a standard power cable (Line,Neutral,Gnd) coming from existing power source in the field. This source will supply both power and the communication medium for the system, therefore, it should be of the highest quality possible. The cable should be passed through the PG connector at the bottom of the box, and then the connector should be tightened on it for sealing. Safety Note: The power should be connected after all settings and mounting were done LCD (display): The LCD will turn on when power is supplied to the unit. Saftey The concentrator is compliant with various safety standards including FCC/CE. Its internal power supply is compliant with UL and CE standards. The concentrator should be connected only to 100-230Vac power source. Damages to the phone caused by using other unsupported power sources would not be covered by the manufacturer’s warranty. 88 Gisin St. Petach-Tikva 49170 Israel Tel: +972-3-9213484 Fax: +972-3-9213482 Mobix Wireless Solutions ltd. 88 Gisin St. Petah-Tikva, 7160 ISRAEL Tel. Fax Web E-mail +972-3-9213484 +972-3-9213482 www.mobix.com info@mobix.com Operating: Turning ON the Concentrator Unit: 1) Connect the mains cable to the internal connector If power is not turned on (power led stays off), check for live power in the mains. 2) The LCD will show the application software version 3) Meanwhile, the BB2 LED will start functioning, as followed: POWER LED (RED) should be always ON MCU LED (Green) – Starts blinking slowly, and after a few minutes (when modem connects to the network) it should stay permanently ON. 4) The concentrator will show the current time as stored in the RTC. Important notice: The concentrator will get a time update from a connected hand held terminal or from the remote server if modem is installed. 5) At that point the system is ready for complete operation 88 Gisin St. Petach-Tikva 49170 Israel Tel: +972-3-9213484 Fax: +972-3-9213482 Page 12 of 17 Mobix Wireless Solutions ltd. 88 Gisin St. Petah-Tikva, 7160 ISRAEL Tel. Fax Web E-mail +972-3-9213484 +972-3-9213482 www.mobix.com info@mobix.com Page 13 of 17 The FCC Wants You to Know This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: a) Reorient or relocate the receiving antenna. b) Increase the separation between the equipment and receiver. c) Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. d) Consult the dealer or an experienced radio/TV technician. FCC Warning A distance of at least 20cm. between the equipment and all persons should be maintained during the operation of the equipment. Modifications not expressly approved by the manufacturer could void the user authority to operate the equipment under FCC Rules. NOTE: THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT. 88 Gisin St. Petach-Tikva 49170 Israel Tel: +972-3-9213484 Fax: +972-3-9213482 Mobix Wireless Solutions ltd. 88 Gisin St. Petah-Tikva, 7160 ISRAEL Tel. Fax Web E-mail +972-3-9213484 +972-3-9213482 www.mobix.com info@mobix.com Page 14 of 17 Troubleshooting Please follow the troubleshooting section in case of encountering troubles with this sub-section 1) The BB2 is plugged to the power supply but Power LED or LCD remains in OFF state. Check if power supply is turned ON (if this option exists) Check if power supply plug is connected well to the BB2 Check if LCD cable is connected to the BB2 Check the input voltage level of the BB2. It should be in range of 9 – 30 VDC Consider replacing the power cable Consider replacing the BB2 2) The BB2 is plugged to the power supply but LCD shows a static black/half black display Verify correct jumper configuration on J3 (see jumper configurations) Verify LCD cable is connected correctly Make sure BB2 was programmed with the current sw version 3) The MCU LED blinks continuosly without switching to permanent ON state – modem cannot connect to the network (if modem is connected) Make sure the communication parameters are correct (APN domain, IP, Port etc) Check the SIM card – it should be inserted correctly in place and with a correct GPRS package Make sure the modem is firmly connected to the board 4) No time appears on the display after 5 minutes from power on (if modem is connected) In GSM modems: Ensure the SIM card is installed properly inside the modem There are few countries (like Peru) were this procedure takes long time. That is normal Change the position of the modem’s antenna. Either the receiving signal is poor or the network cannot ‘hear’ the modem well. 88 Gisin St. Petach-Tikva 49170 Israel Tel: +972-3-9213484 Fax: +972-3-9213482 Mobix Wireless Solutions ltd. 88 Gisin St. Petah-Tikva, 7160 ISRAEL Tel. Fax Web E-mail +972-3-9213484 +972-3-9213482 www.mobix.com info@mobix.com Turn the power OFF and ON Consider replacing the antenna Consider locating the BB2 elsewhere (if possible) 5) A request was sent to the concentrator by the handheld reader, but nothing happened afterwards Ensure RS232 serial cable is correctly connected Verify Bluetooth device operation (if existing) Make sure you are using a compatible handheld reader with latest sw Power reset the concentrator and try again 6) The concentrator shows meters in its list but there are no readings Make sure that the meters details are correct (ID) Check that the communication wires are connected to CON2 on BB2 Check that the communication wires are connected to PLC Verify that TX LED on the PLC is blinking from time to time Verify correct jumper configuration on J4 (see jumper configurations) 7) The PLC shows constant TX or none at all Check that the communication wires are connected to CON2 on BB2 Check that the communication wires are connected to PLC Verify correct jumper configuration on J4 (see jumper configurations) 88 Gisin St. Petach-Tikva 49170 Israel Tel: +972-3-9213484 Fax: +972-3-9213482 Page 15 of 17 Mobix Wireless Solutions ltd. 88 Gisin St. Petah-Tikva, 7160 ISRAEL Ofir Appelbaum R&D Engineer Tel +972-3-9213484 (ext. 36) E-mail ofir_appelbaum@mobix.com Tel. Fax Web E-mail +972-3-9213484 +972-3-9213482 www.mobix.com info@mobix.com Technical Support Tel. +972-3-9213484 (Sun-Thu, 09:00 – 18:30) Fax +972-3-9213482 E-mail info@mobix.com APPENDIX General schematic Data port GSM antenna in AC in 88 Gisin St. Petach-Tikva 49170 Israel Tel: +972-3-9213484 Fax: +972-3-9213482 Page 16 of 17 Mobix Wireless Solutions ltd. 88 Gisin St. Petah-Tikva, 7160 ISRAEL Tel. Fax Web E-mail +972-3-9213484 +972-3-9213482 www.mobix.com info@mobix.com Mounting Wall Mounting plates 88 Gisin St. Petach-Tikva 49170 Israel Tel: +972-3-9213484 Fax: +972-3-9213482 Page 17 of 17
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Encryption : Standard V2.3 (128-bit) User Access : Print, Print high-res Create Date : 2011:09:27 06:33:33Z Modify Date : 2011:09:27 06:33:54Z XMP Toolkit : 3.1-701 Creator Tool : Nitro PDF Reader (1. 4. 0. 11) Metadata Date : 2011:09:27 06:33:54Z Format : application/pdf Creator : Title : Description : Keywords : Producer : Nitro PDF Reader (1. 4. 0. 11) Document ID : uuid:002daff9-7264-4812-acb8-a656501fe652 Page Layout : OneColumn Page Mode : UseNone Page Count : 17EXIF Metadata provided by EXIF.tools