Motorola Solutions 89FT7636 3630SMC Outdoor Subscriber Module User Manual rev

Motorola Solutions, Inc. 3630SMC Outdoor Subscriber Module rev

User manual rev

     PMP 320 Hardware Installation                                                          PMP320HDW2v1 JUL 2010 Preliminary  © 2010 Motorola, Inc. All Rights Reserved
Preliminary JUL 2010    Accuracy  While  reasonable  efforts  have  been  made  to  assure  the  accuracy  of  this  document,  Motorola,  Inc.   assumes  no liability  resulting  from  any  inaccuracies  or  omissions  in  this  document,  or  from  use  of  the  information  obtained herein.  Motorola, Inc.  reserves the right to make changes to any products described herein to improve reliability, function, or design, and reserves the right to revise this document and to make changes from time to time in content hereof with no obligation to notify any person of revisions or changes.  Motorola, Inc.  does not assume any liability arising out of the application or use of any product, software, or circuit described herein; neither does it convey license under its patent rights or the rights of others. It is possible that this publication may contain references to, or information about Motorola products (machines and programs), programming, or services that are not announced in your country.  Such references or information must not be construed to mean that Motorola intends to announce such Motorola products, programming, or services in your country. Copyrights  This  document,  Motorola  products,  and  3rd  Party  Software  products  described  in  this  document  may  include or  describe  copyrighted  Motorola  and  other  3rd  Party  supplied  computer  programs  stored  in  semiconductor memories or other media.  Laws in the United States and other countries preserve for Motorola, its licensors, and other 3rd Party supplied software certain exclusive rights for copyrighted material, including the exclusive right to  copy,  reproduce  in  any  form,  distribute  and  make  derivative  works  of  the  copyrighted  material.   Accordingly, any copyrighted material of Motorola, its licensors, or the 3rd Party software supplied material contained in the Motorola  products  described  in  this  document  may  not  be  copied,  reproduced,  reverse  engineered,  distributed, merged or modified in any manner without the express written permission of Motorola. Furthermore, the purchase of Motorola products shall not be deemed to grant either directly or by implication,  estoppel,  or otherwise,  any license  under  the  copyrights,  patents  or  patent  applications  of  Motorola  or  other  3rd  Party  supplied  software, except  for  the  normal  non-exclusive,  royalty  free  license  to  use  that  arises  by  operation  of  law  in  the  sale  of  a product. Restrictions  Software and documentation are copyrighted materials.  Making unauthorized copies is prohibited by law.  No part of  the  software  or  documentation  may  be  reproduced,  transmitted,  transcribed,  stored  in  a  retrieval  system,  or translated into any language or computer language, in any form or by any means, without prior written permission of Motorola, Inc.  License Agreements  The software described in this document is the property of Motorola, Inc and its licensors. It is furnished by express license agreement only and may be used only in accordance with the terms of such an agreement. High Risk Materials  Components, units, or 3rd Party products used in the product described herein are NOT fault-tolerant and are NOT designed, manufactured, or intended for use as on-line control equipment in the following hazardous environments requiring  fail-safe  controls:   the  operation  of  Nuclear  Facilities,  Aircraft  Navigation  or  Aircraft  Communication Systems, Air Traffic Control, Life Support, or Weapons Systems (High Risk Activities).  Motorola and its supplier(s) specifically disclaim any expressed or implied warranty of fitness for such High Risk Activities. Trademarks     Motorola and the Stylized M Logo are registered in the US Patent & Trademark Office. All other product or service names are the property of their respective owners.    The CE mark confirms Motorola, Inc. statement of compliance with EU directives applicable to this product. Copies of the Declaration of Compliance and installation information in accordance with the requirements of EN50385 can be  obtained  from  the  local  Motorola  representative  or  by  contacting  the  Customer  Network  Resolution  Center (CNRC). The 24 hour telephone numbers are listed at     htt=      s:=    /=    /=      y  e=         t o=     r=     k=     s=      po=     r=     t=        .     ot=    o=     r=     o=     l=    a=         .c=     o=  Select Customer Network  Resolution  Center  contact  information.   Alternatively  if  you  do  not  have  access  to  CNRC  or  the internet, contact the Local Motorola Office.
JUL 2010 Preliminary   Table of Contents  Contents ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■  ■   PMP 320 Hardware Installation  Revision history  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2 Version information   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2 General information  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3 Purpose   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3 Cross references .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3 Document banner definitions   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3 Text conventions .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4 Contacting Motorola .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5 Escalate the problem to the PMP 320 Support Team .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5 U.S. and Canada .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5 Latin America and Central America  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5 Europe, Middle East, and Africa .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5 Asia Pacific    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6  Chapter 1:  Product Description  Access Point (AP)   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 1-3 Site preparation  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 1-5 Cluster Management Module 4 (CMM4) .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 1-6 What is included when the CMM4 unit is shipped  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 1-8 Point to Multi-point Cluster Subscriber Module 320 .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 1-9 Site considerations.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 1-10 Point to Multi-point Connectorized Cluster Subscriber Module 320  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 1-11 Site considerations.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .
Preliminary JUL 2010     .  .  .  .  .  .  .  . 1-12  Chapter 2:  AP Hardware Installation  Installing the AP Hardware   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2-2 Assembling the AP and attaching to a tower .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2-2 Assembling the AP and connecting the antenna  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2-5 Earth Ground cable assembly and connection  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2-11 LED indicator   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2-14 Attach the AP assembly to a pole   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2-15 Surge Suppression Information   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2-19 AP Hardware Installation complete   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2-19  Chapter 3:  CMM4 Hardware Installation  Before you begin .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3-3 AvoidingHazards   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3-3 Grounding Equipment  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3-3 Grounding Infrastructure Equipment   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3-4   PMP320HDW2v1 i
JUL 2010 Preliminary   Contents Conforming to Regulations.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3-4 Protecting Cables and Connections   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3-4 Testing the Components .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3-4 Unpacking Components  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3-5 Installation Overview   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3-6 Installing the GPS Antenna   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3-7 Recommended Tools for GPS Antenna Mounting.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3-7 Mounting a GPS Antenna   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3-7 GPS Coax Cable  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3-8 Installing the power supply for the CMM4 .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3-10 56 VDC Power Supply Installation  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3-10 30 VDC Power Supply Installation  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3-12 Surge Suppressors .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3-13 600SSD and 200SSB Surge Suppressor installation  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3-13 L-COM Surge Suppressor installation  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3-14 Installing the CMM4 .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3-17 Cabling a CMM4 .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3-20 LED indicators .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3-23 Power Faults .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3-24 Configuring CMM4 ports   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3-25 Other Installation Considerations   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3-25 Chapter  4: Cables  DC Cables  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4-2 Ethernet Cables  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4-3
Preliminary JUL 2010   CMM Sync Cable.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4-5 Chapter 5:  CSM Hardware Installation  Before you begin .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5-2 Additional material required for installation .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5-2 Pre-installation planning .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5-3 Components shipped with the CSM   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5-3 Cabling Overview   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5-4 Installing the CSM .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5-6 Selecting a location for the CSM .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5-6 Installation Overview   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5-7 Completing the mounting bracket assembly .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5-7 Attaching the CSM and mounting the bracket assembly outside the building  .  .  .  .  .  .  .  . 5-8 Fastening the CSM and mounting the bracket assembly to a pole  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5-9 Aligning the CSM for best signal strength .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5-10 Connecting the CSM to the Ethernet cable, Earth Ground, the Surge Suppressor .  .  .  .  .  .  .  . 5-12 Ethernet Cable Assembly   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5-12 Running cables through the wall of the building .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5-14 Installing the 600SSD Surge Suppressor.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5-15 Connecting the ground wire .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5-16 Connecting the power supply and the Ethernet cable to the computer.  .  .  .  .  .  .  .  .  .  .  . 5-17 Chapter 6:  Connectorized CSM Hardware Installation  Before you begin .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6-3 Additional material required for installation .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6-3 Pre-installation planning .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6-4 Components shipped with the CSM   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6-4 Cabling Overview   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6-5 Installing the CSM .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6-7 Selecting a location for the CSM .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6-7 ii PMP320HDW2v1
JUL 2010 Preliminary   Content  Installation Overview   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6-8 Completing the mounting bracket assembly .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6-8 Attaching the CSM and mounting the bracket assembly outside the building  .  .  .  .  .  .  .  . 6-9 Fastening the CSM and mounting the bracket assembly to a pole  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6-10 Connecting the Antenna Cables to the Unit   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6-11 Connecting the CSM to the Ethernet cable, Earth Ground, the Surge Suppressor .  .  .  .  .  .  .  . 6-13 Ethernet Cable Assembly   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6-13 Running cables through the wall of the building .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6-15 Installing the 600SSD Surge Suppressor.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6-16 Connecting the ground wire .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6-17 Connecting the power supply and the Ethernet cable to the computer.  .  .  .  .  .  .  .  .  .  .  . 6-18  Chapter 7:  Connectorized CSM Antenna Installation Instructions  Antenna Types used with the Connectorized CSM .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 7-2 Dual Polarization/Dual Slant Subscriber Antenna   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 7-2 Omni Directional Base Station Antenna  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 7-6 Chapter 8:  Regulatory, Legal, and Safety Notices  IMPORTANT NOTE ON MODIFICATIONS .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8-2 NATIONAL AND REGIONAL REGULATORY NOTICES .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8-3 U.S. Federal Communication Commission (FCC) Notification   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8-3 Industry Canada Notification   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8-4 European Union Notification .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8-5 Equipment Disposal  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8-5 EU Declaration of Conformity for RoHS Compliance .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8-5 Labeling and Disclosure Table for China .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8-6 RF EXPOSURE SEPARATION DISTANCES .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8-7 Details of Exposure Separation Distances Calculations and Power Compliance Margins .  .  . 8-7 Software License Terms and Conditions  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8-9 Hardware Warranty in US  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8-12 LIMIT OF LIABILITY .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8-13
Preliminary JUL 2010   iv PMP320HDW2v1
JUL 2010 Preliminary   List of Figures  List of Figures ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■  ■  ■  ■  ■ Figure 1-1:  High Level Network Diagram  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 1-2 Figure 1-2:  Access Point (AP) shown with antenna attached and mounted on pole.  .  .  .  .  .  .  . 1-3 Figure 1-3:  AP, radio only   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 1-4 Figure 1-4:  CMM4 with door open .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 1-6 Figure 1-5:  CSM 320 subscriber module .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 1-9 Figure 1-6:  Connectorized CSM 320 subscriber module .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 1-11 Figure 1-7:  Connectorized CSM 320 rear view subscriber module .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 1-11 Figure 2-1:  Pipe Clamp Assembly Identification  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2-4 Figure 2-2:  AP and antenna parts with scissors bracket  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2-4 Figure 2-3:  LED location diagram  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2-14 Figure 2-4:  Mounting the AP to the tower  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2-15 Figure 3-1:  AP Installation and wiring .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3-2 Figure 3-2:  600SSD surge suppressor connectors  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3-13 Figure 3-3:  L-COM surge suppressor   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3-15 Figure 3-4:  CMM4 unit opened showing connection details  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3-18 Figure 3-5:  CMM4 connection diagram located on the door of the unit   .  .  .  .  .  .  .  .  .  .  .  .  . 3-20 Figure 3-6:  Port Status Showing Power Fault   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3-25 Figure 4-1:  RJ-45 Straight-through connections  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4-4 Figure 4-2:  Pin 1 Location diagram   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4-4 Figure 4-3:  CMM sync cable pinouts .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4-6 Figure 4-4:  CMM sync cable pinouts .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4-6 Figure 5-1:  CSM (CPE) 320 Identification  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5-1 Figure 5-2:  CSM components   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5-4 Figure 5-3:  CSM mounted to a wall   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5-5 Figure 5-4:  Ethernet cable weather protection assembly   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5-12 Figure 5-5:  Cable connections from the surge suppressor to the CSM power injector and the
Preliminary JUL 2010   CSM  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5-16 Figure 5-6:  CSM 320 power injector .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5-16 Figure 6-1:  Connectorized CSM (CPE) 320 Identification   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6-2 Figure 6-2:  Connectorized CSM (CPE) 320 Rear View Connectors .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6-2 Figure 6-3:  CSM components   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6-5 Figure 6-4:  CSM mounted to a wall   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6-6 Figure 6-5:  Connectorized CSM antenna cable connector location.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6-11 Figure 6-6:  Ethernet cable weather protection assembly   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6-13 Figure 6-7:  Cable connections from the surge suppressor to the CSM power injector and the CSM  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6-17 Figure 6-8:  CSM 320 power injector .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6-17 Figure 7-1:  Dual Polarization/Dual Slant Subscriber Antenna  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 7-2 Figure 7-2:  Mounting Bracket Parts Identification .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 7-5 Figure 7-3:  Dual Polarized / Dual Slant Subscriber Antenna Rear View for Mounting Assembly .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 7-5 Figure 7-4:  Omni Directional Base Station Antenna Identification .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 7-7 Figure 7-5:  Omni Directional Base Station Antenna Parts Identification .  .  .  .  .  .  .  .  .  .  .  .  . 7-8 Figure 7-6:  Omni Directional Base Station Antenna Bracket Identification   .  .  .  .  .  .  .  .  .  .  . 7-9 Figure 8-1:  Disclosure Table .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8-6   Figure 8-2:  Peak power density calculation   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8-7  PMP320HDW2v1 v
JUL 2010 Preliminary   List  of  Figures List of Tables ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■  ■  ■  ■  ■  Table 1-1:  Spectrum Range Operation .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 1-2 Table 1-2:  CAP 320 Antenna Specifications   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 1-5 Table 1-3:  CAP 320 Physical Specifications   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 1-5 Table 1-4:  CMM4 Model Numbers and Ethernet Switch Configurations .  .  .  .  .  .  .  .  .  .  .  .  . 1-7 Table 2-1:  Part list for the antenna and AP .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2-3 Table 2-2:  LED indicators for the AP .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2-14 Table 3-1:  Cable description .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3-9 Table 3-2:  LED Indicators for the CMM4.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3-24 Table 4-1:  Wire size for CMM4 DC cable .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4-2 Table 4-2:  Recommended Ethernet Cables .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4-3 Table 4-3:  Recommended Ethernet Cables .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4-4 Table 5-1:  CSM parts list.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5-3 Table 6-1:  CSM parts list.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6-4 Table 7-1:  Dual Polarized / Dual Slant Subscriber Antenna Electrical Specifications .  .  .  .  .  .  . 7-3 Table 7-2:  Dual Polarized / Dual Slant Subscriber Antenna Mechanical Specifications .  .  .  .  .  . 7-3 Table 7-3:  Dual Polarized / Dual Slant Subscriber Antenna Environmental Specifications  .  .  .  . 7-3 Table 7-4:  Dual Polarized / Dual Slant Subscriber Antenna Parts List   .  .  .  .  .  .  .  .  .  .  .  .  .  . 7-4 Table 7-5:  Omni Directional Base Station Antenna Electrical Specification   .  .  .  .  .  .  .  .  .  .  . 7-7 Table 7-6:  Omni Directional Base Station Antenna Mechanical Specification   .  .  .  .  .  .  .  .  .  . 7-7 Table 7-7:  Omni Directional Base Station Antenna Environmental Specification .  .  .  .  .  .  .  .  . 7-8 Table 7-8:  Omni Directional Base Station Antenna Pole Mounting Parts List .  .  .  .  .  .  .  .  .  .  . 7-8 Table 8-1:  FCC IDs and the specific configurations   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8-3 Table 8-2:  Industry Canada Certification Numbers and the specific configuration .  .  .  .  .  .  .  . 8-4 Table 8-3:  Calculated exposure distances and power compliance margins .  .  .  .  .  .  .  .  .  .  .  . 8-8 Table 8-4:  Exposure separation distances  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8-8        PMP320HDW2v1 vii
Preliminary JUL 2010   GuideAbout This Manual      PMP 320 Hardware Installation ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■  ■  ■  ■  ■    What is covered in this manual?   The audience for this document includes network planners, system operators, network administrators, and equipment installers.  This installation manual covers the physical installation procedures of the hardware for the PMP 320 product line which encompass the Cluster Access Point (CAP or AP), Cluster Manager Module 4 (CMM4), and the Cluster Subscriber Module (CSM).  Software installation and configuration information for the AP and the CSM are covered in the PMP 320 Administration and Configuration .                                        PMP320HDW2v1 1
JUL 2010 Preliminary   Revision  history     Revision history  ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■  ■  ■   The following sections show the revision status of this document.   Version information   The following table describes the changes made to this document:  Version Date of issue Description  1 JUL 2010 Preliminary version for FCC/UL review.                                                2 PMP320HDW2v1
Preliminary JUL 2010   General  information      General information  ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■              ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■              ■             ■             ■             ■             ■             ■             ■  ■  ■    Purpose   Motorola documents provide the information to operate, install, and maintain Motorola equipment.  It is recommended that all personnel engaged in such activities be properly trained by Motorola.  Motorola disclaims all liability whatsoever, implied or expressed, for any risk of damage, loss or reduction in system performance arising directly or indirectly out of the failure of the customer, or anyone acting on the customer's behalf, to abide by the instructions, system parameters, or recommendations made in this document.  These documents are not intended to replace the system and equipment training offered by Motorola.  They can be used to supplement and enhance the knowledge gained through such training.  NOTE  If this document was obtained when attending a Motorola training course, it is not updated or amended by Motorola.  It is intended for TRAINING PURPOSES ONLY. If it was supplied under normal operational circumstances, to support a major software release, then Motorola automatically supplies corrections and posts on the Motorola customer website.    Cross references   References made to external publications are shown in italics.  Other cross references, emphasized in blue text in electronic versions, are active links to the references.  This document is divided into numbered chapters that are divided into sections.  Sections are not numbered, but are individually named at the top of each page, and are listed in the table of contents.   Document banner definitions   A banner indicates that some information contained in the document is not yet approved for general customer use.  A banner is oversized text on the bottom of the page, for example, PRELIMINARY — UNDER DEVELOPMENT           PMP320HDW2v1 3
JUL 2010 Preliminary   Text  conventions      Text conventions   The following conventions are used in Motorola documents to represent keyboard input text, screen output text, and special key sequences.   Input  Characters typed in at the keyboard are shown like this sentence. Items of interest within a command appear like this sentence.   Output   Messages, prompts, file listings, directories, utilities, and environmental variables that appear on the screen are shown like this sentence. Items of interest within a screen display appear like this sentence.   Special key sequences  Special key sequences are represented as follows:  CTRL-c or CTRL+C Press the Ctrl and C keys at the same time. CTRL-SHIFT-c or CTRL+SHIFT+C Press the Ctrl, Shift, and C keys at the same time. ALT-f or ALT+F Press the Alt and F keys at the same time. ALT+SHIFT+F11 Press the Alt, Shift and F11 keys at the same time. ¦ Press the pipe symbol key. RETURN or ENTER Press the Return or Enter key.                          4 PMP320HDW2v1
Preliminary JUL 2010   Contacting  Motorola      Contacting Motorola  ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■  ■  ■   Motorola appreciates feedback from users about our customer documents.  Contact the technical support team in your area with any feedback or issues with the documents.  When sending E-mail or calling Motorola for technical support, please include, as appropriate, the software release on each module, the IP addresses, MAC addresses, and features enabled on the system.   Escalate the problem to the PMP 320 Support Team   Escalate any issues to the Wireless Broadband Support Team by contacting the support team in your area.   U.S. and Canada   E-mail:  EMS-EICC-RM@motorola.com  Telephone:  1–866–961–9288   Latin America and Central America   E-mail:  EMS-EICC-RM@motorola.com  Telephone: • Argentina:  0800–666–2789  • Brazil:  0800–891–4360  • Columbia:  01–800–912–0557  • Mexico:  001–800–942–7721  • Peru:  0800–70–086  • All other Latin and Central American countries:  +420 533 336 946    Europe, Middle East, and Africa   E-mail:  essc@motorola.com         PMP320HDW2v1 5
JUL 2010 Preliminary   Asia  Pacific      Telephone: • Denmark:  043682114  • France:  0157323434  • Germany:  06950070204  • Italy:  0291483230  • Lithuania:  880 030 828  • Netherlands:  0202061404  • Norway:  24159815  • Portugal:  0217616160  • Spain:  0912754787  • Russia:  810 800 228 41044  • Saudi Arabia:  800 844 5345  • South Africa:  0800981900  • United Kingdom:  0203 0277499    Asia Pacific   E-mail:  WiBBsupport.apac@motorola.com  Telephone: • +6048503854 (9 AM through 5 PM Malaysia time)  • +420 533 336 946 (outside the 9 am through 5 PM hours)                         6 PMP320HDW2v1
Preliminary JUL 2010   Chapter 1       Product Description ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■              ■               ■             ■             ■             ■              ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■  ■  ■  ■  ■ A PMP 320 Access Network provides a low cost point-to-multipoint broadband solution optimized for fixed outdoor applications.  The access point is an 802.16e micro base station with WiMAX 802.16e CSM interoperability.  The system offers an integrated, all-outdoor solution with simple installation for rapid deployment.  Target applications for the PMP 320 Access Network include: • Tier 1, Tier2, or Tier 3 carriers.  Where the PMP 320 system provides a cost-effective, reliable broadband connectivity for residential and business customers.  • Government network operators, where the PMP 320 system provides broadband-based infrastructure for administrative networks.  • Wireless service providers, with broadband network service for any size operation.  • Wireline service providers, with broadband wireless extensions for existing DSL or cable networks.  As shown in Figure 1-1, a "Raintight" PMP 320 network consists of : • APs - Cluster Access Point (CAP) 320 Access Points, usually tower-mounted in a four-sector configuration.  • CPE - Cluster Subscriber Module (CSM) 320, Customer Premise Equipment (CPE), or also known as Subscriber Module (SM) is usually mounted on a residence or other structure, and powered by a power adapter providing standard 802.3af power over Ethernet.  • CMM4 (Cluster Management Module 4) – is an outdoor enclosed unit housing a GPS module connected to a GPS antenna.  It contains synchronization and power-injection circuitry, surge protection, and a managed switch.  The CMM is used to provide custom synchronization over power over Ethernet to the APs as well as offering a networked, managed switch.                     PMP320HDW2v1 1-1
JUL 2010 Preliminary   Asia Pacific Chapter 1: Product Description      Figure 1-1   High Level Network Diagram    High Level Network Diagram     Internet    Core Network   Radio Access Network   AP   CMM4      Router (optional)     CPE  AAA Server EMS (optional) DHCP Server DNS Server (optional) (e.g., Wireless Manager) (optional) (optional)     In addition, a PMP 320 network normally requires: • AAA Server – Authentication, Authorization, and Accounting server using the RADIUS (Remote Authentication Dial In User Service) protocol  • EMS – an Element Management System, such as the Motorola One Point Wireless Manager  • DHCP Server – Dynamic Host Configuration Protocol server  • DNS Server – Domain Name System server  • CNUT – Network Update Tool for updating device software  • Router – optional  Motorola offers PMP 320 equipment that operates in the spectrum ranges as shown in  Table 1-1   Spectrum Range Operation  Licensed Spectrum Ranges System Name AP Name SM Name AP Model Number SM Model Number Supported Frequencies  = 3.3 GHz to 3.4 GHz 3.4 GHz to 3.6 GHz  PMP 35320  CAP 35320  CSM 35320  3530APC 3530SM 3.3 GHz to 3.6 GHz  3.6 GHz to 3.8 GHz PMP 36320  CAP 36320  CSM 36320 3630APC 3630SM  3.6  GHz  to  3.8 GHz  (Includes 3.65  GHz)        1-2 PMP320HDW2v1
1-20 PMP320HDW2v1 Preliminary JUL 2010   PMP 320 Hardware Installation Access Point (AP)     Access Point (AP)  ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■  ■  ■   A PMP 320 Access Point (AP) is an 802.16e micro base station that connects wirelessly to up to 200 PMP 320 Cluster Subscriber Modules (CSMs) or CPEs (Customer Premise Equipment).  The AP consists of a antenna and radio, as shown in Figure 1-2, with the radio shown separately in Figure 1-3.  The standard antenna is a dual-polarity 16.5 dBi antenna typically mounted in a four 90° sector configuration.  The AP is manageable by local web interface, as well as SNMP or the Motorola One Point Wireless Manager.   WARNING  Installing an AP involves height, electricity, and exposure to RF (radio frequency) energy. To avoid personal injury, follow applicable national and local safety regulations along with industry best practices. Also follow the specific guidelines in this document, including maintaining a sustained exposure separation distance of 50 cm (~20 inches) as described in the Regulatory, Legal, and Safety Notice in this document.    Figure 1-2   Access Point (AP) shown with antenna attached and mounted on pole    Rotate Up To vertical poistion.                   Radio attached to Antenna with Appropriate Hardware
PMP320HDW2v1 1-21 Preliminary JUL 2010   Access Point (AP) Chapter 1: Product Description      Figure 1-3   AP, radio only                              The PMP 320 AP uses 802.16e for the over-the-air connection to the SMs or CSM. It is 802.16e PHY and MAC compliant, and complies with the WiMAX Wave2 profile, except for mobility.  The AP uses a custom 56 VDC power system, typically powered by a CMM4.  The AP uses less than 25 W per AP, or less than 100 watts for 360° coverage.  The AP includes integrated surge suppression that is the equivalent to the 600SSD surge suppressor recommended for the CSM (Cluster Subscriber Module) installations.  The AP functions as a router in the network, with routes to the CSMs (or SMs) auto-configured. The AP supports ICMP and ARP.  The AP: • can be configured to either receive its IP address from a network DHCP server, or be manually assigned its IP address.  • can be configured to respond to SM DHCP requests either by relaying the requests to a network DHCP server, or function as a DHCP server itself.  • can be configured either to use an external AAA (Authentication, Authorization, and Accounting) server, or use a minimal internal AAA server.  When configured to use an external AAA server, the AP serves as a relay between CSMs (SMs) and the AAA server for authentication requests, and serves as a RADIUS client communicating with the AAA server for authorization of SM services.  • has an embedded web server for configuring using a web browser.  • supports SNMP v1, and uses standard 802.16e MIBs (Management Information Base) as well as the Motorola 802.16e AP MIB. The AP supports all Object Identifiers (OIDs) with SNMP v1 and SNMP v2, however all traps are SNMP v1.
1-22 PMP320HDW2v1 Preliminary JUL 2010   PMP 320 Hardware Installation Site preparation      Table 1-2   CAP 320 Antenna Specifications  CAP 320 Antenna Specifications  Antenna Beam Width 16.5 dBi gain Dual Polarity +/- 45 4 sector application (actual 3 dB antenna pattern:  60 degree horizontal   Table 1-3   CAP 320 Physical Specifications  CAP 320 Physical Specifications  Power Consumption < 25 Watts  Temperature -40° F to +131° F (-40° C to +55° C)  Wind Survival 118 miles/hr (190 km/hr)  Dimensions (LxWxD) Integrated:  ~711 x 195 x 240mm Connectorized:  ~330 x 195 x 140mm  Weight Integrated:  5.5 kg Connectorized:  2.2 kg  For additional information regarding spectrum and frequency information, refer to the PMP 320 Administration and Configuration Guide located at:  http://motorola.wirelessbroadbandsup- . port.com/support/library/   Site preparation   Review the following site requirements before selecting the site for the installation of the PMP 320 CAP: • Verify that a good Earth Ground can be achieved at the site.  • Verify that the power to the site is reliable and can be backed up by an uninterruptible power supply (UPS).  • Verify that access to the site is easy if an urgent need arises.  (It can take up to forty-five minutes to key-down the transmitters at certain locations.)  • Verify that the site is secure.  • Be sure to negotiate a contract with the site owner that allows easy swap-out of existing equipment without an added cost.  • Accurately measure the latitude and longitude of the location for future reference.
PMP320HDW2v1 1-23 Preliminary JUL 2010   Cluster Management Module 4 (CMM4) Chapter 1: Product Description     Cluster Management Module 4 (CMM4)  ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■  ■  ■   The Cluster Management Module 4 (CMM4) provides power, synchronization, and network connectivity for up to eight APs, backhauls, and Ethernet terrestrial feeds in a variety of configurations.   Figure 1-4   CMM4 with door open                       Cabling Diagram on Inside of Front Door      The CMM4 provides: • Sync over Power over Ethernet and integrated surge suppression on the controller board for up to 8 APs or BHs.  Both a custom 30 VDC power scheme and a custom 56 VDC power scheme are available.  Neither is the same as the later IEEE Standard 802.3af, and neither is compatible with it.  • Managed switching using a hardened EtherWAN switch.  The CMM4 ships with a 14-port EtherWAN switch and is also available without a switch.  • A weather-tight enclosure with either 4 or 7 glands/ports for Ethernet and power cables.  • Surge suppression on the controller board for the incoming 30V DC and 56V DC power lines and GPS coax cable.
1-24 PMP320HDW2v1 Preliminary JUL 2010   PMP 320 Hardware Installation Cluster Management Module 4 (CMM4)      • Auto-negotiation on the Ethernet ports.  Ports will auto-negotiate to match inputs that are either 100Base-T or 10Base-T, and either full duplex or half duplex, when the connected device is set to auto-negotiate.  Alternatively, these parameters are settable.  • An always-on NTP (Network Time Protocol) server that can provide date and time to any radio that can reach the CMM’s management IP address.   Table 1-4   CMM4 Model Numbers and Ethernet Switch Configurations  CMM4 Model CMM4 Extended EtherWAN Switch Number Model Number Total Ports 10/100 Base –TX Ports 10/100/1000 Base-TX Ports Cable Glands (ports)    1090CK  1090CKBA (current units)  1090CKAA (earlier units)  14 12 2 7   9 8 1 4  1091 NA No  Switch 7  Inside the CMM4 enclosure is a controller board, an EtherWAN switch, and a GPS coax surge suppressor.  Also inside the CMM4 enclosure is the EtherWAN switch port.  This connection is where the Ethernet Gigabit connection is made.  For more information about the EtherWAN switch and how the port is managed or for information on earlier versions of the CMM4 units refer to the Cluster Management Module 4 User Guide located at: . http://motorola.wirelessbroadbandsupport.com/  The controller board injects power and synchronization on up to eight Ethernet ports and provides the equivalent of 600SSD surge suppression on each of the eight ports.  The controller board is managed using a web browser, or SNMP, and is supported by the Prizm Element Management System (EMS). The controller board receives 30 VDC power and/or 56 VDC from external power supplies, and provides 20 VDC power for the EtherWAN switch and other auxiliary equipment.  The controller board includes a GPS module, which provides sync and GPS information to the CMM, a management port, an override toggle switch, and an auxiliary sync port for connecting to another CMM.   NOTE  The controller board does not convert 30 VDC to 56 VDC or 56 VDC to 30 VDC. To power 56 VDC equipment from a CMM4 you must provide a 56 VDC power supply, and to power 30 VDC equipment from a CMM4 you must provide a 30 VDC power supply.   The CMM4 requires a GPS antenna and a power supply.  The directions for installing the power supply and the GPS are provided in Chapter 3 CMM4 Hardware Installation.
PMP320HDW2v1 1-25 Preliminary JUL 2010   What is included when the CMM4 unit is shipped Chapter 1: Product Description      What is included when the CMM4 unit is shipped   The CMM4 as shipped includes: • Weatherized enclosure containing the controller board, EtherWAN Ethernet Switch, and GPS coax surge suppressor  • Patch cables between the controller board and the EtherWAN Ethernet Switch  • U-bolts and V-brackets for pole-mounting the CMM4  • GPS Antenna  • GPS antenna pole-mount kit  • A 1-hole cable gland insert for use on the DC power cable  The CMM4 as shipped does not include: • Any power supply.  The appropriate power supply(s), 30 VDC and/or 56 VDC, must be ordered separately  • Ethernet cables to connect the CMM4 to APs, backhauls, or terrestrial feeds  • Coax cable connecting the CMM4 to the GPS antenna  • DC power line cables are not provided (AC power line cables are not included with the power supplies)
1-26 PMP320HDW2v1 Preliminary JUL 2010   PMP 320 Hardware Installation Point to Multi-point Cluster Subscriber Module 320     Point to Multi-point Cluster Subscriber Module 320  ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■              ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■              ■             ■             ■             ■             ■             ■              ■  ■  ■    Figure 1-5   CSM 320 subscriber module  Canopy  CSM 320                  Ethernet Connector Front Rear   The PMP 320 Cluster Subscriber Module (CSM) or also known as the Customer Premise Equipment (CPE), or the Subscriber Module (SM) is the device that extends the broadband network or internet services to the end user through communication with the PMP 320 AP. The key features of the CSM are:  • an integrated 14.5 dBi gain antenna  • 802.3af power over Ethernet (4 VDC)  • 802.16e standard fixed, outdoor solution  • products that are available in the 3.3 GHz – 3.8 GHz spectrum  The CSM is managed by a local web interface, SNMP, or the Motorola Wireless Manager.  The CSM also functions as a Network Address Translation (NAT) device.
PMP320HDW2v1 1-27 Preliminary JUL 2010   Site considerations Chapter 1: Product Description      Site considerations   Review the following site requirements before selecting the site for the installation of the PMP 320 CSM: • When ordering CSMs for the site, ensure that the same band CSM is ordered as is used for the AP.  • Mount the CSM as high off the ground as possible to minimize theft.  • Communicate to the end-user that they are responsible for the loss/damage to the CSM while in their care.  • Route and hide the ENET cables against the house following local installation codes.  This extra effort lowers the chance of a new home owner taking down the CSM and its wiring.  • Avoid penetrating the roof; this will help mitigate issues with leaks.  • Work with the local home owners association (HOA) to receive approval of the CSM solution.  • Take several measurements to several different AP locations, the closest AP might not be the best signal.  • Perform a RF survey of the surrounding area; chances are that this installation will ignite more interest in this solution in the area.
1-28 PMP320HDW2v1 Preliminary JUL 2010   PMP 320 Hardware Installation Point to Multi-point Connectorized Cluster Subscriber Module 320     Point to Multi-point Connectorized Cluster Subscriber Module 320  ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■  ■  ■    Figure 1-6   Connectorized CSM 320 subscriber module           G1_CCSMfrtpanelview.eps    Figure 1-7   Connectorized CSM 320 rear view subscriber module    G1_CCSM_rearviewconn.ext   The PMP 320 Connectorized Cluster Subscriber Module (CSM) or also known as the Customer Premise Equipment (CPE), or the Subscriber Module (SM) is the device that extends the broadband network or internet services to the end user through communication with the PMP 320 AP. The key features of the CSM are:
PMP320HDW2v1 1-29 Preliminary JUL 2010   Site considerations Chapter 1: Product Description      • 802.3af power over Ethernet (48 VDC)  • 802.16e standard fixed, outdoor solution  • products that are available in the 3.3 GHz – 3.8 GHz spectrum  The Connectorized CSM is managed by a local web interface, SNMP, or the Motorola Wireless Manager.  The Connectorized CSM also functions as a Network Address Translation (NAT) device.   Site considerations   Review the following site requirements before selecting the site for the installation of the PMP 320 CSM: • When ordering Connectorized CSMs for the site, ensure that the same band Connectorized CSM is ordered as is used for the AP.  • Mount the Connectorized CSM as high off the ground as possible to minimize theft.  • Communicate to the end-user that they are responsible for the loss/damage to the Connectorized CSM while in their care.  • Route and hide the ENET cables against the house following local installation codes. This extra effort lowers the chance of a new home owner taking down the Connectorized CSM and its wiring.  • Avoid penetrating the roof; this will help mitigate issues with leaks.  • Work with the local home owners association (HOA) to receive approval of the Connectorized CSM solution.  • Take several measurements to several different AP locations, the closest AP might not be the best signal.  • Perform a RF survey of the surrounding area; chances are that this installation will ignite more interest in this solution in the area.
  Chapter 2       AP Hardware Installation ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■  ■  ■  ■  ■  This chapter provides the instructions and procedures needed to: • connect the antenna brackets  • connect the AP radio antenna to the antenna  • cable the unit  • mount the unit to a pole, mounting fixture, or tower  • ground the unit  • connect surge suppression                                       PMP320HDW2v1 2-1 JUL 2010 Preliminary
2-2 PMP320HDW2v1 Preliminary JUL 2010   CDGuideInstalling the AP Hardware Chapter 2: AP Hardware Installation     Installing the AP Hardware  ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■  ■  ■   General communications equipment, infrastructure, and facilities site design should be performed in line with Motorola’s Standards and Guidelines for Communications Sites  (also  known  as  the  R56  manual)  available  from:  https://motorolawls. motolms.com/Secure/Course_Description.asp?number=ANT001- .  A short coaxial cable from the radio terminates in a male N connector.  The antenna has a chassis-mounted female N connector.  The antenna includes tower mount brackets with adjustable down-tilt.  Installing an AP typically consists of the following phases: 1. Configure the AP at an operator's facility or at the installation site using the information and settings defined in the Planning and Configuring sections of the PMP 320 Administration and Configuration .  2. Assemble the AP (radio,  antenna,  and brackets) and physically install it using Procedure 2-1.  A CMM4 is typically installed at the same time, if not previously installed.  3. Cable the AP to the CMM4 and ground it to Protective Earth – PE using Procedure 2-2.  4. This phase can also include cabling to backhauls, or running terrestrial feeds.  5. Confirm operation, using CSMs in the field.  Local practices and choices of installation options will dictate the actual processes. For example, variations on these generalized procedures can be used to install on a building or install multiple APs on a pipe mount before hoisting up a tower for final attachment.   Assembling the AP and attaching to a tower   Review the following parts identification graphics to ensure that all the top pipe clamp assembly brackets parts are present before beginning the installation.  Refer to Figure 2-1 and Figure 2-2 to see the parts that make up the antenna and AP. The parts consist of:
PMP320HDW2v1 2-3 Preliminary JUL 2010   PMP 320 Hardware Installation Assembling the AP and attaching to a tower      Table 2-1   Part list for the antenna and AP  Part name  Quantity  Antenna 1  AP radio 1  Attaching brackets to antenna  Scissors bracket 1  Top pipe clamp assembly 1  Bottom pipe clamp assembly 1  2.24 inch spacer 2  2.36 inch spacer 1  5/16-18 x 3.5 inch hex pivot 3 bolt  5/16-18  inch  split  lock 3 washer  5/16-18 flat washer 3  5/16-18 hex nut 3  Attaching AP to Antenna  M6 carriage bolt 2  M6 split lock washer 2  M6 flat washer 2  M6 hex nut 2  Attaching pipe clamps to pipe  3/8-16 inch split lock washer 4  3/8-16 inch flat washer 4  3/8-16 hex nut 4
2-4 PMP320HDW2v1 Preliminary JUL 2010   Assembling the AP and attaching to a tower Chapter 2: AP Hardware Installation      Figure 2-1   Pipe Clamp Assembly Identification     TOP PIPE CLAMP ASSEMBLY BOTTOM PIPE CLAMP ASSEMBLY Longer Bracket                   3/8-16 Hex Nut   3/8-16 Split Lock Washer 3/8-16 Lock Washer     3/8-16 Hex Nut    3/8-16 Split Lock Washer  3/8-16 Lock Washer      Figure 2-2   AP and antenna parts with scissors bracket     Pole Is Shown For Reference   Antenna   Radio (Secured on Antenna)         DIV connector MAIN connector    Ethernet
PMP320HDW2v1 2-5 Preliminary JUL 2010 PMP 320 Hardware Installation Assembling the AP and connecting the antenna          Assembling the AP and connecting the antenna   Use the following procedure to assemble the pipe clamp brackets to the AP, and attach the radio to the antenna.  These steps are performed before the AP is mounted on the pole.   Required Tools  • Two ½ inch wrenches  • 9/16 inch wrench and inclinometer  • 10mm socket wrench   Torque Requirements  • 3/8 -16 pipe clamp hardware to 9 ft-lbs (12.2 N.m)  • 5/16-18 mount hardware 10 ft-lbs (13.5 N.m)  • M6 hardware 7 ft-lbs (9.5 N.m)    Procedure 2-1   Assemble the AP and antenna for pole mounting   Continued
2-6 PMP320HDW2v1 Preliminary JUL 2010 Assembling the AP and connecting the antenna Chapter 2: AP Hardware Installation Procedure 2-1   Assemble the AP and antenna for pole mounting (Continued)     1 Perform a parts check to ensure all parts are present.                                2 Connect the pipe clamp assembly brackets to the antenna.  NOTE  Determine between the two pipe clamp assemblies which bracket has the longer bracket bar.  The bracket with the longer bar is attached to the bottom of the antenna. The bracket with the shorter bar is used for the top of the antenna and connected to the scissors downtilt bracket.       Continued
PMP320HDW2v1 2-7 Preliminary JUL 2010 PMP 320 Hardware Installation Assembling the AP and connecting the antenna          Procedure 2-1   Assemble the AP and antenna for pole mounting (Continued)       TOP PIPE CLAMP ASSEMBLY BOTTOM PIPE CLAMP ASSEMBLY Longer Bracket                   3/8-16 Hex Nut   3/8-16 Split Lock Washer 3/8-16 Lock Washer     3/8-16 Hex Nut    3/8-16 Split Lock Washer  3/8-16 Lock Washer    3 Using the longer bracket pipe clamp (Bottom pipe clamp assembly) attach the bracket to the bottom of the antenna using a 5/16-18 x 3.5 inch hex pivot bolt, 5-16 hex nut.  Spacer (2.24in)       5/16-8 x 3.5in Hex Pivot Bolt 5/16-8 Hex Nut          5/16-8 Split Lock Washer 5/16-8 Flat Washer     Continued
2-8 PMP320HDW2v1 Preliminary JUL 2010 Assembling the AP and connecting the antenna Chapter 2: AP Hardware Installation Procedure 2-1   Assemble the AP and antenna for pole mounting (Continued)     4 Using a 5/16-18 x 3.5 hex pivot bolt, 5-16 split lock waster, 5/16 split flat washer, smaller spacer (2.36 inches) and a 5/16 hex nut, connect the scissor bracket to the top of the antenna. See Detail A     5/16-8 Split Lock Washer Outside         5/16-8 Hex Nut   5/16-8 Flat Washer   5/16-8 x 3.5in Hex Pivot Bolt    Spacer (2.36in)  Detail A     Inverted Scissor Mount  5 Using the bracket with the shorter bar, attach the downtilt scissor bracket pointing up (inverted scissor mount) to avoid physical interference between the bracket and the radio housing.  Connect the scissor bracket to the short pipe bracket to the scissor bracket by attaching the 5/16-18 x 3.5 inch hex pivot bolt, 5/16-18 flat washer, shorter spacer (2.24 inches) and the 5/16 – 18 hex nut.        Continued
PMP320HDW2v1 2-9 Preliminary JUL 2010 PMP 320 Hardware Installation Assembling the AP and connecting the antenna           Procedure 2-1   Assemble the AP and antenna for pole mounting (Continued)   See Detail A    NOTE  Use Shorter Spacer (2.24in)               5/16-8 Hex Nut                     Detail A 5/16-8 Flat Washer        5/16-8 x 3.5in Hex Pivot Bolt 5/16-8 Split Lock Washer  Use a level (inclinometer) to tilt of the antenna when installing at the site.  The scissor bracket has degree markings from 0 to 15 on the bracket, but it is recommended for accuracy to use a level. 6 Connect the radio to the antenna by sliding it into the captive space. Radio  2X M6 Hex Nut 2X M6 Lock Washer 2X M6 Flat Washer     NOTE: Slide Radio into captive space of Antenna First then secure with mounting hardware          2X M6 Carriage Bolt Antenna
2-10 PMP320HDW2v1 Preliminary JUL 2010 Assembling the AP and connecting the antenna Chapter 2: AP Hardware Installation Procedure 2-1   Assemble the AP and antenna for pole mounting (Continued)     Continued
PMP320HDW2v1 2-11 Preliminary JUL 2010 PMP 320 Hardware Installation Assembling the AP and connecting the antenna     7 Secure the radio to the antenna using the two M6 carriage bolts, M6 flat washers; M6 split lock washer and the M6 hex nut.  Torque the M6 nut 7 ft-lbs (9.5 N.m).  The unit is shown away from the antenna in order to illustrate bolt locations.    Pole Is Shown For Reference Antenna    Radio M6 Carriage Bolt  M6 Flat Washer M6 Lock Washer M6 Hex Nut     M6 Carriage Bolt  M6 Flat Washer M6 Lock Washer M6 Hex Nut  DIV Connector  MAIN Connector   8 Connect the cable labeled:  • MAIN to the antenna connector labeled MAIN  • with no label to the antenna connector labeled DIV (Diversity).   Continued
2-12 PMP320HDW2v1 Preliminary JUL 2010     PMP 320 Hardware Installation Earth Ground cable assembly and connection      Procedure 2-1   Assemble the AP and antenna for pole mounting (Continued)      Pole Is Shown For Reference   Antenna   Radio (Secured on Antenna)           VIEW A DIV connector MAIN connector          Earth Ground cable assembly and connection   Standard installation practices apply which include: • use of shielded Ethernet cable for all infrastructure cabling  • use of drip loops at any point where the cable changes direction  • extra cable (a splice loop) is provided for future use at any termination  • ensuring the tower or structure is fully grounded (Protective Earth – PE)  • use water tight tape, followed by electrical tape on all N-connectors    Procedure 2-2   Cabling and grounding the AP   Continued
PMP320HDW2v1 2-13 Preliminary JUL 2010     Earth Ground cable assembly and connection Chapter 2: AP Hardware Installation      Procedure 2-2   Cabling and grounding the AP (Continued) 1 Remove the connection protection casing using the thumb release at the back of the AP Unit.  2 Use dielectric grease (which is uniformly non-conducting) on all connections and in all RJ-45 Ethernet connectors.  The best practice is to use enough grease to fill the RJ- 45 female connector, and then insert the RJ-45 male connector and push the grease further into the unit and around the RJ-45 connector.  Excess grease can be wiped over the connector area to provide some resistance to water ingress around the connector.  Connect the Ethernet cable to the connector labeled ETHERNET. Note that the AUX port is not used at this time.    Continued
2-14 PMP320HDW2v1 Preliminary JUL 2010     PMP 320 Hardware Installation Earth Ground cable assembly and connection      Procedure 2-2   Cabling and grounding the AP (Continued)    3 Run a 10 AWG ground strap from the ground lug on the AP to known good ground (Protective Earth - PE).                   AP Ground Lug  Ground the radio to the tower. 4 Be sure to reattach the bottom cover of the AP connection cover.
PMP320HDW2v1 2-15 Preliminary JUL 2010     LED indicator Chapter 2: AP Hardware Installation      LED indicator   The LED display for the AP are either Green or off.   Figure 2-3   LED location diagram                                 Table 2-2   LED indicators for the AP  LED Description  PWR  (D14) Power – green indicates the DC power is  on.   This  LED  indicates  that  the board  is  powered  on.  SYN/1  (D13)  Synchronization indicator – this indicator is on whenever the AP is synchronized with the GPS, or when ever the GPS is not used at all.  SES/2  (D12) Not used,  but is always ON.  LNK/5  (D9) GMAC Ethernet – the LED is on when the GMAC Ethernet link is up.  ACT/4  (D10) Activity – indicates activity on the ENET port.  GPS/3  (D11)  GPS  pulse  indicator  –  this  LED  is  on every 1 pps interrupt, and turned off 20 frames after 100 milliseconds).
2-16 PMP320HDW2v1 Preliminary JUL 2010 Attach the AP assembly to a pole Chapter 2: AP Hardware Installation          Attach the AP assembly to a pole    WARNING  Maintain a safe distance from RF exposure when mounting the AP on the tower 50 cm (20 inches).  Maintain a safe distance from power lines.   The network planner should provide the antenna pattern information for the installation.  The network is planned from true north 0 degrees.  Use a compass to ensure there is no overlap of the antennas as they are installed.   Figure 2-4   Mounting the AP to the tower    AP       Communications Bldg    Cable Tray  BT-0781S-XXX    BT-0781S-XXX  AP Grounded to Tower with 10AWG wire   Network Switch or Router CMM4 Drip Loop   600SSD     AC Power        SGPN4076 200SSB Tower Ground        Earth Ground       Tower
PMP320HDW2v1 2-17 Preliminary JUL 2010 PMP 320 Hardware Installation Attach the AP assembly to a pole          NOTE   • The L-COM surge suppressor is used if the Gigabit Ethernet port is used in the CMM4.  The L-COM when used is installed either in the CMM4 cabinet, or installed inside the communications building. • This figure shows the GPS near the top of the AP unit.  For installation information about the GPS refer to Installing the GPS Antenna on page 3-7. • The AC line cord is not provided with the hardware.   This figure shows the GPS near the top of the AP unit.  For installation information about the GPS refer to Installing the GPS Antenna on page 3-7.   Procedure 2-3   Attaching the AP assembly to a pole    1 Using standard work and safety practices for tower climbing, connect the assembled unit (assembled antenna, brackets and radio) to a pole, mounting fixture, or a tower.  The unit must be mounted to avoid accidental touching by personnel.  The standard mounting height is typically at least 4 m (13 ft) above ground level.    Pole Is Shown For Reference   Antenna   Radio (Secured on Antenna)         DIV connector MAIN connector    Ethernet     NOTE  Approximate cable distance between the AP and the CMM4 is 100 meters.  Continued
2-18 PMP320HDW2v1 Preliminary JUL 2010 Attach the AP assembly to a pole Chapter 2: AP Hardware Installation          Procedure 2-3   Attaching the AP assembly to a pole (Continued) 2 Install the top and bottom clamps to the pipe.  Slide the clamp bracket on to the carriage bolts.  Slide on a 3/8-16 flat washer, 3/8-16 split lock washer and a 3/8-16 hex nut to each carriage bolt.  NOTE   • Align the AP setting the desired downtilt degree using the inclinometer. • The network planner should provide the antenna pattern information for the installation.  The network is planned from true north 0 degrees.  Use a compass to ensure there is no overlap of the antennas as they are installed.  Tighten the hex nut to 10 ft-lbs (13.5 N.m) after the AP has been aligned to the optimum downtilt position. 3 Connect the Ethernet cable from the AP to the CMM4 port controller.  There are up to 14 ports in one CMM4 switch, but only 8 ports on the CMM4 motherboard that can power up a radio.  Ensure that surge suppression has been installed for this connection.  See the section on Surge Suppression Information.  Follow the site plan created by the network planner when connecting cables to the CMM4 switch.           Continued
PMP320HDW2v1 2-19 Preliminary JUL 2010 PMP 320 Hardware Installation Attach the AP assembly to a pole     PWR GND 1 3 5 7 9 11   2 4 6 8 1012 13 14POWER DEFAULT GPS_M ETHERNET PWR ACTIVITY LINK SYNC OK ET       GPS      SWITCH2 4 6 8 4 6 83 5 7 3 5 7     Procedure 2-3   Attaching the AP assembly to a pole (Continued)      TOTAL 20 VDC ACCESSORY POWER IS NOT TO EXCEED 20 WATTS.  ACCESSORY POWER OUTPUTS  +20 V       +20 V   Twist wire pair 1 twist per inch and form three loops around ferrite core for RF emission compliance.  Short wire to ChassisGround at Switch mounting screw for RF emission compliance.  Green Black Red     EtherWAN Switch ( Power Port View )  NOTE: Refer to the System User Guide for the power requirement of the switch OUTPUT OUTPUT specific to the switch part number.  GND (Black)   REDUNDANT +V (Red)  +29 V  REDUNDANT +29 V            +56 V  +56 V    INPUT INPUT INPUT INPUT GND GND +V  GND        GND +V      +V  GND  +V  GND  +V  GND +V  GND  PE     CMM4 CONTROLLER ( Power Port View ) EXTERNAL PROTECTIVE EARTH GROUND  +29 V       +56 V EtherWAN Switch OUTPUT Red OUTPUT Green  RS232 ( Ethernet Port View )  OR   Red Green +29 V       +56 V 1000 BaseT    1000 BaseT DEFAULT NORMAL OUTPUT OUTPUT   AUX SYNC ETHERN TOGGLE SHIELDED ETHERNET CABLES   LEDs  N Connector INTERNAL GPS CABLE CMM4 CONTROLLER ( Ethernet Port View )  MAC ADDRESS IP ADDRESS TO GPS ANTENNA  CAUTION: Damage my result if non-approved equipment is connected to powered parts.   IMPORTANT See the System User Guide before connecting to power.  The Guide is available on-line at http://motorola.wirelessbroadbandsupport.com/software/    www.motorola.com  P/N: 5487639D03 CMM4 CONTROLLER PORT 1        PORT 2        PORT 3        PORT 4        PORT 5        PORT 6        PORT 7        PORT 8        PORT 9        PORT 10      PORT 11      PORT 12      PORT 13      PORT 14
Preliminary JUL 2010     PMP 320 Hardware Installation Surge Suppression Information      Surge Suppression Information   The AP has metal-to-metal contact from the tower or support structure, through the antenna, through the coax cable, to the radio.  Installing surge suppression at the AP is strongly recommended to provide the best protection from lightning strikes.  Up to four 600SSD surge suppressors can be mounted in series on an Ethernet link without degrading the link.  The equivalent of a 600SSD is built into each of the 8 ports on a CMM4 and counts as one of the four.  As an example, a typical installation might have properly-grounded 600SSD units within 3 ft (1 m) of each AP and additional properly-grounded 600SSD units on each Ethernet cable mounted outside at the point of cable entry to a telecommunications hut that contains the CMM4.   AP Hardware Installation complete   The AP hardware installation is complete.  Refer to the PMP 320 Administration and Configuration Guide to update software or configure the device.                                           PMP320HDW2v1 2-19
JUL 2010 Preliminary     AP Hardware Installation complete Chapter 2: AP Hardware Installation                                                                       2-20 PMP320HDW2v1
Preliminary JUL 2010     Chapter 3       CMM4 Hardware Installation ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■  ■  ■  ■  ■  The CMM4 consists of three subsystems: • the CMM4 enclosure and controller board  • power supplies  • an EtherWAN switch (mounted in the CMM4 enclosure).                                              PMP320HDW2v1 3-1
JUL 2010 Preliminary     AP Hardware Installation complete Chapter 3: CMM4 Hardware Installation      Figure 3-1   AP Installation and wiring   AP       Communications Bldg    Cable Tray  BT-0781S-XXX    BT-0781S-XXX  AP Grounded to Tower with 10AWG wire   Network Switch or Router CMM4 Drip Loop   600SSD     AC Power        SGPN4076 200SSB Tower Ground        Earth Ground       Tower     NOTE   • The L-COM surge suppressor is used if the Gigabit Ethernet port is used in the CMM4.  The L-COM when used is installed either in the CMM4 cabinet, or installed inside the communications building. • This figure shows the GPS near the top of the AP unit.  For installation information about the GPS refer to Installing the GPS Antenna on page 3-7. • The AC line cord is not provided with the hardware.         3-2 PMP320HDW2v1
3-24 PMP320HDW2v1 Preliminary JUL 2010     PMP 320 Hardware Installation Before you begin     Before you begin  ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■  ■  ■   Ensure that you comply with standard local or national electrical and climbing procedures when you install the CMM4.   WARNING  Installing a CMM involves electrical power and can involve height and exposure to RF (Radio Frequency) energy.  To avoid personal injury, know and follow applicable national and local safety regulations and industry best practices, and follow the specific guidelines in this document   If the CMM4 is being installed on a tower instead of a communications hut, the operator will have to calculate the wind loading on the tower for the addition of the CMM4.   Avoiding Hazards   Use simple precautions to protect staff and equipment.  Hazards include exposure to RF waves, lightning strikes, and power surges.  This section specifically recommends actions to abate these hazards.   Grounding Equipment   Effective lightning protection diverts lightning current safely to ground, Protective Earth (PE). It neither attracts nor prevents lightning strikes.
PMP320HDW2v1 3-25 Preliminary JUL 2010     Grounding Infrastructure Equipment Chapter 3: CMM4 Hardware Installation      Grounding Infrastructure Equipment   To protect both your staff and your infrastructure equipment, implement lightning protection as follows: • Observe all local and national codes that apply to grounding for lightning protection.  • Before you install your modules, perform the following steps: Engage a grounding professional if you have any questions on grounding.  Install lightning arrestors to transport lightning strikes away from equipment.  For example, install a lightning rod on a tower leg other than the leg to which you mount your module.  Connect your lightning rod to ground.  Plan to use an appropriate surge suppressor on any Ethernet cable at the point where it enters any building or structure.   • Install your modules at least 2 feet (0.6 meters) below the tallest point on the tower, pole, or roof.    Conforming to Regulations   For all electrical purposes, ensure that your network conforms to applicable country and local codes, such as the NEC (National Electrical Code) in the U.S.A. If you are uncertain of code requirements, engage the services of a licensed electrician.  In particular, many codes require that wired electrical devices like the 56 VDC power supply either terminate in a plug connection or be wired with an on/off switch, and not be hard-wired to AC/mains.   Protecting Cables and Connections   Cables that move in the wind can be damaged, impart vibrations to the connected device, or both.  At installation time, prevent these problems by securing all cables with cable ties, cleats, or weather-resistant tape.  The cable can be a path for water to follow to enter the cable connector or even the module. You can prevent this problem by including and securing a drip loop where the cable enters the module enclosure.   Testing the Components   The best practice is to connect all the components - BHs, APs, GPS antenna, and CMM4 - in a test setting and initially configure and verify them before deploying them to an installation. However, circumstances or local practice may require a different practice.
3-26 PMP320HDW2v1 Preliminary JUL 2010     PMP 320 Hardware Installation Unpacking Components      Unpacking Components   When you receive products, carefully inspect all shipping boxes for signs of damage.  If you find damage, immediately notify the transportation company.  As you unpack the equipment, verify that all the components that you ordered have arrived. Save all the packing materials to use later, as you transport the equipment to and from installation sites.
PMP320HDW2v1 3-27 Preliminary JUL 2010     Installation Overview Chapter 3: CMM4 Hardware Installation     Installation Overview  ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■  ■  ■   Before beginning the physical installation of the CMM4 hardware make sure the GUI configuration is completed.  Refer to configuration details in the PMP 320 Administration and Configuration Guide for additional information on the GUI configuration procedures.  The physical installation of the CMM4 includes the following: • physically install the CMM on the tower (or near the communications hut)  • physically install the GPS unit (included with the CMM4, does not have to be ordered separately)\  • physically install the surge suppressors  • cable the following CMM4 components: GPS  Power  ENET  600SSD surge suppressor  200SB surge suppressor  L-COM surge suppressor (if the Gigabit Ethernet port is in use at this site, the L-COM must be installed inside the CMM4 unit, or inside the communication’s hut, this item is never installed out doors)  Earth to ground
3-28 PMP320HDW2v1 Preliminary JUL 2010     PMP 320 Hardware Installation Installing the GPS Antenna     Installing the GPS Antenna  ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■  ■  ■   Outside the CMM4 enclosure, the CMM4 requires a GPS antenna and power supply.  The GPS antenna must be installed in an area with clear access for strong signal reception, but does not need to be mounted high on the tower.   NOTE  Orient the GPS antenna so it has clear access to the southern horizon, up to 20 degrees.  Do not install the GPS as the highest object at the site.   Information on GPS cable planning, ordering, and design is covered in GPS Coax Cable on page 3-8.  The following information describes the recommended tools and procedures to mount the GPS antenna.   Recommended Tools for GPS Antenna Mounting   The following tools and materials are needed for mounting the GPS antenna: • 3/8 inch nut driver  • 12 inch adjustable wrench  • 7/16 inch wrench  • Needle-nose pliers  • electrical tape for all GPS connections  • water-tight tape for all GPS connections    Mounting a GPS Antenna   Perform the following procedure to mount a GPS antenna.
PMP320HDW2v1 3-29 Preliminary JUL 2010          GPS Coax Cable Chapter 3: CMM4 Hardware Installation       Procedure 3-1   Mounting the GPS Antenna   1 Ensure that the mounting position:  • has an unobstructed view of the sky to 20º above the horizon.  • must not be the highest object on the tower.  (The GPS antenna does not need to be particularly high on a site, which would give it more exposure to lightning.  It just needs to have an unobstructed view of the southern horizon.)  • is not further than 100 feet (30.4 meters) of cable from the CMM. 2 Select a pole that has an outside diameter of 1.25 to 1.5 inches (3 to 4 cm) to which the GPS antenna bracket can be mounted. 3 Attach the GPS unit to the bracket using 4 screws. 4 Place the U-bolts (provided) around the pole. 5 Slide the GPS antenna bracket onto the U-bolts. 6 Slide the ring washers (provided) onto the U-bolts. 7 Slide the lock washers (provided) onto the U-bolts. 8 Use the nuts (provided) to securely fasten the bracket to the U-bolts. 9 Connect the GPS coax cable to the female N-connector on the GPS antenna. See the section GPS Coax Cable for additional details on the length and type of coaxial cable needed. 10 Use water type tape and electrical tape to seal the connector.    GPS Coax Cable   The operator provides the GPS antenna coaxial cable between the CMM4 and the GPS antenna. It must be engineered to length, and is not included with the CMM4.  In most cases, the cable length from the CMM4 to the GPS antenna must be less than 30 m (~100 ft).
3-30 PMP320HDW2v1 Preliminary JUL 2010     http://best-PMP 320 Hardware Installation GPS Coax Cable      Antenna cables can be ordered from Best-Tronics, Inc., . Antenna cables can be ordered in lengths up to 100 ft (30.4 m). tronics.com/motorola.htm  Table 3-1   Cable description  Best-Tronics Part Number Description  BT-0564 N to N GPS antenna cable  Alternatively, equivalent cables may be procured by the operator, fabricated by the operator in a depot, or fabricated at site using • Up to 100 feet (30.4 meters) of LMR200 coaxial cable  • 2 Times Microwave N-male connectors (Times Microwave P/N TC-200-NM) or equivalent connectors   NOTE  The CMM4 has a female N-type coax connector on the outside of the enclosure, whereas the CMM micro has a female BNC-type connector inside the enclosure.  Take this into account when ordering or fabricating cables, and when replacing a CMM micro with a CMM4.
PMP320HDW2v1 3-31 Preliminary JUL 2010     1 Install the CMM4 power supply in a hut, wiring closet, or weatherized NEMAapproved enclosure.  It is designed for extreme temperatures but it is imperative to keep moisture away from the power converter. 2 Do not install the power supply within the CMM4 enclosure as it will increase the heat within the enclosure to an unacceptable level.  The CMM4 enclosureis large to provide surface area for heat dissipation without the use of forced convection fans, not to provide space for additional high-power electronics. 3 For the DC side of a 56 VDC power supply, engineer the DC cable, selecting the wire gage from Table 4-1.  Use either UV-resistant cable or shield the cable (as in a conduit) from UV rays. 4  Installing the power supply for the CMM4 Chapter 3: CMM4 Hardware Installation     Installing the power supply for the CMM4  ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■             ■             ■             ■             ■             ■  ■  ■    WARNING  Although the output of the power supply is 29 VDC or 56 VDC, the power rating classifies the converter as a Class 2 electric device.  For this reason, whenever you work on power in the CMM4, you must first disconnect the DC supply from the AC power source.   Select the appropriate procedure to install the power supply for the CMM4.  Directions are provided for a 56 VDC power supply and a procedure on how to install the 30 VDC power supply.  If using both 30 VDC and 56 VDC, a 1000 Ohm 5W resistor must be installed across the 30 VDC +V and GND at the terminal block.   56 VDC Power Supply Installation   Use the following procedure to install a 56 VDC power supply for the CMM4.   Procedure 3-2   Installing a 56 VDC Power Supply for the CMM4                Connect the DC cable on the top of the connector.  Insert the +V lead into the terminal 7 cage clamp and insert the GND (ground/return) lead into the terminal 4 cage clamp.  To insert a lead into a cage clamp, insert a thin-blade screwdriver in the secondary cage clamp hole and lever the screwdriver away from the main cage clamp hole.  Continued
3-32 PMP320HDW2v1 Preliminary JUL 2010     AUX 2 AUX 1 convertIN   5 For the AC side of a 56 VDC power supply, connect an AC cable to the power supply using Ground/protective earth, Neutral (N), and Line (L). To insert a lead into a cage clamp, insert a thin-blade screwdriver in the secondary cage clamp hole and lever the screwdriver away from the main cage clamp hole.        1 2 3       N L Input  The AC line cord is not provided with the hardware. 6 Terminate the other end of the AC cable to a country-specific AC connector or wire to a switch in accordance with local electrical codes. AUX 2AUX 1PMP 320 Hardware Installation 56 VDC Power Supply Installation      Procedure 3-2   Installing a 56 VDC Power Supply for the CMM4 (Continued)   Output  +  + - -+  + - -                        N          L Input  power -one-     OUT   Output +  +  -   -   +  +   -   - select     NOTE  AC connection on top, DC on bottom.
PMP320HDW2v1 3-33 Preliminary JUL 2010     30 VDC Power Supply Installation Chapter 3: CMM4 Hardware Installation      30 VDC Power Supply Installation   If the PMP 320 will be co-located with PMP 100 equipment on the same CMM4, refer to the Cluster Management Module 4 User Guide at http://motorola.wirelessbroadbandsupport.com/ for additional information on how to install the 30 VDC power supply, and the 1000 Ohm 5 W resistor that must be installed along with that power supply.
3-34 PMP320HDW2v1 Preliminary JUL 2010     PMP 320 Hardware Installation Surge Suppressors     Surge Suppressors  ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■  ■  ■   The outdoor mounting of the CMM4 requires the 600SSD, 200SSB, and in certain cases the LCOM surge suppressor.  The L-COM surge suppressor is used only if the Gigabit Ethernet port is being used on the CMM4 switch.  The L-COM surge suppressor can be installed in the CMM4 unit.  The overall installation instructions are as follows: • ground the 600SSD and the 200SSB to Earth Ground  • connect the protected side of the 200SSB to the AC power supply SGPN4076  • connect the protected side of the 600SSD to the network switch or router in the communications hut.  • add drip loops at any point in the cabling where the cable changes direction.    NOTE  Additional L-COM considerations during installation:  if the CMM4 unit is mounted on the antenna and is located more that three feet away from the communications hut, an additional L-COM surge suppressor must be installed.     Figure 3-2   600SSD surge suppressor connectors     Surge Suppressor            All cables must exit through the allocated slots          600SSD and 200SSB Surge Suppressor installation   Use the following procedure to install the 600SSD and the 200SB surge suppressors.
PMP320HDW2v1 3-35 Preliminary JUL 2010     L-COM Surge Suppressor installation Chapter 3: CMM4 Hardware Installation      CAUTION  Observe caution when drilling through the wall of the building. Ensure that there are no power lines, gas lines, water lines, or data lines in the wall at the desired location where the drilling takes place.    Procedure 3-3   Surge suppressor installation and cable connections   1 Attach the surge suppressor to the communication hut near the cable access point to the inside of the communications hut using two screws. 2 Remove the surge suppressor front cover to access the Ethernet RJ-45 jacks. 3 Connect the Ethernet cable from the CMM4 to the Ethernet port on the surge suppressor port. 4   CAUTION  Follow local building codes for penetrating buildings.  Observe caution when drilling through the wall of the building. Ensure that there are no power lines, gas lines, water lines, or data lines in the wall at the desired location.  Drill a 3/4 inch (18 mm) hole through the wall of the communications hut at the desired location. 5 Connect the Ethernet cable from the network or switch router from the communications hut to the Ethernet port on the 600SSD surge suppressor. 6 Use dielectric grease (which is uniformly non-conducting) on all connections and in all RJ-45 Ethernet connectors.  The best practice is to use enough grease to fill the RJ-45 female connector, and then insert the RJ-45 male connector and push the grease further into the unit and around the RJ-45 connector.  Excess grease can be wiped over the connector area to provide some resistance to water ingress around the connector. 7 Ground the surge suppressor to Earth Ground. 8 Install the surge suppressor front cover to the base of the unit ensuring that the cables are all routed through the cable slots.    L-COM Surge Suppressor installation   The L-COM surge suppressor is used only when the Gigabit Ethernet port is used on the CMM4 switch.  The L-COM must be installed inside the CMM4 unit, or inside the communication’s hut, this item is never installed outdoors.
3-36 PMP320HDW2v1 Preliminary JUL 2010     PMP 320 Hardware Installation L-COM Surge Suppressor installation      Figure 3-3   L-COM surge suppressor   2X Grounding Lugs and Te r m i n a l s Lockable Hinged Cover                2X RJ45 Jacks 2X Cable Grommets    Procedure 3-4   L-COM surge suppressor installation   1 Determine whether the L-COM surge suppressor will be installed inside the CMM4 unit or outside the unit. 2 Remove the front cover of the surge suppressor to access the Ethernet RJ-45 jacks. 3 If the unit is installed:  • inside the CMM4 unit, continue to step 4.  • outside the CMM4 unit in the communications hut, continue to step 8. 4 Place the L-COM surge suppression unit inside the CMM4 housing.  Be careful not to place the surge suppressor in the unit as to crush any cables in the CMM4 unit or cables going through the cable glands. 5 Connect the Gigabit Ethernet connection from the CMM4 to the L-COM Ethernet connector. 6 Connect the Ethernet cable from the L-COM surge suppressor and feed the cable through the cable gland on the CMM4 and connect to the switch in the communications hut. 7 Connect the Earth Ground on the surge suppressor to the Earth Ground in theCMM4 cabinet, continue to step 13. 8 Install the L-COM surge suppressor inside the communications hut using two screws. 9 Connect the Gigabit Ethernet cable to the Ethernet cable connection in the L-COM surge suppressor. 10 Connect the Ethernet cable from the surge suppressor to the switch in the communications hut.  Continued
PMP320HDW2v1 3-37 Preliminary JUL 2010     L-COM Surge Suppressor installation Chapter 3: CMM4 Hardware Installation      Procedure 3-4   L-COM surge suppressor installation (Continued) 11 Connect the Ethernet cable from the CMM4 to the Ethernet port on the surge suppressor port. 12 Connect the surge suppressor to the Earth Ground. 13 Place the cover on the L-COM unit and attach the L-COM cover.
3-38 PMP320HDW2v1 Preliminary JUL 2010     4 User guide PMP 320 Hardware Installation Installing the CMM4     Installing the CMM4  ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■  ■  ■   Install the CMM4 outside only when temperatures are above –4° F (–20° C). The gland openings and the bushings and inserts in the gland openings are rated for the full –40° to +131° F (–40° to +55° C) range of the CMM4.  However, for dynamic operations (loosening, tightening, and inserting), they are compliant at, and rated for, only temperatures at or above –4° F (–20° C).  For more information about configuring the CMM4 device, refer to the Cluster Manager Module located at: . http://motorola.wirelessbroadbandsupport.com/software/  When performing the installation of the CMM4 unit, remember to: • install the CMM4 outside the communications hut whenever possible.  • do not mount the power supply inside the CMM4 enclosure.  • use 200SS for all the DC cables powering the CMM4.  • label all the CMM4 connections.  • do not accidentally toggle the default switch on the CMM4 during installation.  • use the provided glands for all connections for the CMM4.  • Use drip loops at all the transition points on all cables.  • Ensure that the pin 4 selector in the surge suppressor is set isolated (factory default).  • Connect the ground bolt on the CMM4 to the Earth Ground.  • Run the redundant power supplies on different paths
PMP320HDW2v1 3-39 Preliminary JUL 2010     Installing the CMM4 Chapter 3: CMM4 Hardware Installation      Figure 3-4   CMM4 unit opened showing connection details           Cable Gland    Cable Housings          Cabling Diagram on Inside of Front Door      Prizm and Wireless Manager treat the EtherWAN Switch in a CMM4 as a generic switch.  For Prizm or Wireless Manager to correctly associate each EtherWAN Switch with its CMM4: • before you install the CMM4, read and note the MAC address of both the CMM4 controller and EtherWAN switch from the physical units.  • after you discover a CMM4 and its switch, use these MAC addresses for moving the switch to the place in your Prizm or Wireless Manager network view where the CMM4 was discovered.  • always maintain a record that associates these two MAC addresses.    CAUTION  When an EMS discovers an EtherWAN switch in your network, it can’t tell which CMM4 the switch is associated with, nor can it tell CMM4 EtherWAN switches from any other EtherWAN switches you may have in your network.  The pair of MAC addresses you record directly from the CMM4 and its EtherWAN switch are the only means for you to establish the logical connection.   Perform the following procedure to install the CMM4.
3-40 PMP320HDW2v1 Preliminary JUL 2010     PMP 320 Hardware Installation Installing the CMM4       Procedure 3-5   Installing the CMM4    1 Ensure that the mounting position:  • is not farther than 328 feet (100 meters) from the furthest AP or BH that the CMM4 will serve.  • is not closer than 10 feet (3 meters) to the nearest AP or BH.  • is not further than 100 feet (30.5 meters) of cable from the intended mounting position of the GPS antenna.  • allows the doors to open fully open for service. 2 Select a support structure to which the flanges can be mounted. 3 If the support structure is:  • a wall, use screws or bolts (neither is provided) to attach the flanges to the wall.  • an irregular-shaped object, use adjustable stainless steel bands (provided) to attach the CMM4 to the object.  • a pole that has an outside diameter of 1.25 to 3 inches (3 to 8 cm), use a toothed V-bracket (provided) to attach the V-bracket to the pole.  Then attach the CMM4 flanges to the V-bracket.                     4 If the CMM4 is mounted to a non-conducting structure (cinder block wall, for example) or there is any doubt as to a good ground through the structure, run a 10 AWG ground cable from one of the Ground/Earth terminations of one of the terminal blocks inside the CMM4, through a cable gland, and to known good ground.
PMP320HDW2v1 3-41 Preliminary JUL 2010     PWR GND 1 3 5 7 9 11   2 4 6 8 1012 13 14POWER DEFAULT GPS_M ETHERNET PWR ACTIVITY LINK SYNC OK ET       GPS      SWITCH2 4 6 8 4683 5 7 3 5 7Cabling a CMM4 Chapter 3: CMM4 Hardware Installation      Cabling a CMM4    Figure 3-5   CMM4 connection diagram located on the door of the unit      TOTAL 20 VDC ACCESSORY POWER IS NOT TO EXCEED 20 WATTS.  ACCESSORY POWER OUTPUTS  +20 V       +20 V   Twist wire pair 1 twist per inch and form three loops around ferrite core for RF emission compliance.  Short wire to ChassisGround at Switch mounting screw for RF emission compliance.  Green Black Red     EtherWAN Switch ( Power Port View )  NOTE: Refer to the System User Guide for the power requirement of the switch OUTPUT OUTPUT specific to the switch part number.  GND (Black)   REDUNDANT +V (Red)  +29 V  REDUNDANT +29 V            +56 V  +56 V    INPUT INPUT INPUT INPUT GND GND +V  GND        GND +V      +V  GND  +V  GND  +V  GND +V  GND  PE     CMM4 CONTROLLER ( Power Port View ) EXTERNAL PROTECTIVE EARTH GROUND  +29 V       +56 V EtherWAN Switch OUTPUT Red OUTPUT Green  RS232 ( Ethernet Port View )  OR   Red Green +29 V       +56 V 1000 BaseT    1000 BaseT DEFAULT NORMAL OUTPUT OUTPUT   AUX SYNC ETHERN TOGGLE SHIELDED ETHERNET CABLES   LEDs  N Connector INTERNAL GPS CABLE CMM4 CONTROLLER ( Ethernet Port View )  MAC ADDRESS IP ADDRESS TO GPS ANTENNA  CAUTION: Damage my result if non-approved equipment is connected to powered parts.   IMPORTANT See the System User Guide before connecting to power.  The Guide is available on-line at http://motorola.wirelessbroadbandsupport.com/software/    www.motorola.com  P/N: 5487639D03 CMM4 CONTROLLER PORT 1        PORT 2        PORT 3        PORT 4        PORT 5        PORT 6        PORT 7        PORT 8        PORT 9        PORT 10      PORT 11      PORT 12      PORT 13      PORT 14
3-42 PMP320HDW2v1 Preliminary JUL 2010     PMP 320 Hardware Installation Cabling a CMM4      Perform the following procedure to cable the CMM4.   Procedure 3-6   Cabling the CMM4    1 Review the diagram inside the door of the CMM4.  Refer to Figure 3-5. 2 The inserts in the gland openings of the CMM4 have precut holes. 3 Route Ethernet cables through the cable gland connectors to the Ethernet ports inside the CMM4 cabinet (see the grey cables in the illustration). Stagger the cables as shown in the figure to make it easier to feed them through the gland.                                  Continued
PMP320HDW2v1 3-43 Preliminary JUL 2010     Cabling a CMM4 Chapter 3: CMM4 Hardware Installation      Procedure 3-6   Cabling the CMM4 (Continued) 4 Stagger the cables as shown in the figure to make it easier to feed them through the gland.                      5 Connect Ethernet cables as follows:  • APs, BH10s, or BH20s (PTP 100 Series bridges):  cable to powered ports of the controller board.  The controller board provides sync, power, and surge suppression for these connections.  If the CMM4 is mounted inside a building or communications hut, a Motorola 600SSD surge suppressor (model number 600SSC or later) should be mounted outside the building or communications hut on each line at the point of cable penetration to prevent overvoltages and over-currents from entering the building and potentially damaging other electronic equipment.  • Terrestrial feeds under 100 Mbps (10/100BaseT): cable to an unpowered port of the controller board.  The controller board provides surge suppression for these connections.  If the CMM4 is mounted inside a building or communications hut, a Motorola 600SSD surge suppressor (model number 600SSC or later) should be mounted outside the building or communications hut on each line at the point of cable penetration to prevent over-voltages and over-currents from entering the building and potentially damaging other electronic equipment.  • Terrestrial feeds over 100 Mbps (1000BaseT Gigabit Ethernet): cable directly to the Gigabit port of the EtherWAN switch, and mount a Motorola PTP-LPU lightning protection unit or equivalent within 3 ft (1 m) of the CMM4 if the CMM4 is located outdoors on the outside of the building or communications hut at the point of cable penetration if the CMM4 is located indoors.  • PTP 400 Series bridges:  cable to an unpowered port of the controller board.  If the CMM4 is inside a building or communication hut, install the bridge’s PIDU (Powered InDoor Unit) also inside the building, and install a Hyperlink Technologies AL-CAT6HP-JW surge suppressor (only needed in special cases) or equivalent on the outside of the building or communications hut at the point of cable penetration.  If the CMM4 is        Continued
3-44 PMP320HDW2v1 Preliminary JUL 2010       6 On the door label, record the MAC and IP addresses of the CMM4 and all connected equipment. 7 Record also the MAC address of the EtherWAN switch. 8 Consistent with practices in your company, note the above information to add later to the company equipment database. 9 Connect the coax cable from the female N-connector on the GPS antenna to the female N-connector on the outside of the CMM4. 10 Ensure there is an Ethernet cable between the management port on the controller board and one of the Ethernet ports on the EtherWAN switch. 11 Feed the DC power cord through a cable gland.  A 1-hole gland insert is provided, as the DC power cable is too thick to share a gland with other cables.  The 1-hole insert is either connected to one of the patch cables or included in the parts bag. 12 Connecting power to the terminal block:  • For 29 V: Connect the white wire to +29V on either of the 29 VDC terminal blocks.  Connect the black wire to −V (GND) on the same 29 VDC terminal block.  • For 56V: Connect the black and white wire to +56V on either of the 56 VDC terminal blocks.  Connect the black wire to –V (GND) on the same 56 VDC terminal block. 13 Plug the DC power supply into an AC receptacle (AC mains).  NOTE  The AC line cord is not provided with the hardware. 14 Verify that the LEDs light. PMP 320 Hardware Installation LED indicators      Procedure 3-6   Cabling the CMM4 (Continued)   mounted outside, locate the PIDU in a weather-tight enclosure within 3 ft (1 m) of the CMM4 and install a Hyperlink Technologies AL-CAT6HP-JW surge suppressor or equivalent within 3 ft (1 m) of the PIDU.  • PTP 500 and 600 Series bridges:  cable directly to the Gigabit port of the EtherWAN switch.  If the CMM4 is inside a building or communication hut, install the bridge’s PIDU (Powered InDoor Unit) also inside the building, and install a Hyperlink Technologies AL-CAT6HP-JW surge suppressor or equivalent on the outside of the building or communications hut at the point of cable penetration.  If the CMM4 is mounted outside, locate the PIDU in a weather-tight enclosure within 3 ft (1 m) of the CMM4 and install a Hyperlink Technologies AL-CAT6HP-JW surge suppressor or equivalent within 3 ft (1 m) of the PIDU.                                        LED indicators   The indicator LEDs color indicates position, but not the state.  For example, the red Power LED, in the left most position, lights when power is applied to the unit, but does not change color at any point.
PMP320HDW2v1 3-45 Preliminary JUL 2010     Power Faults Chapter 3: CMM4 Hardware Installation      Table 3-2   LED Indicators for the CMM4  LED Color Item  Red Power  Amber Default  Green GPS  Master  Red Ethernet  Switch  Power  Amber Link  Green Activity  Amber Sync  OK    CAUTION  Surge suppressors should be installed on any cables where they enter a building to reduce the possibility of over voltages or over currents damaging any equipment in the building.   The following equipment, mounted outside of a communications hut or building at the point where the cables penetrate the building, is recommended: • Motorola 600SSD surge suppressors for Ethernet cables  • Motorola 200SS surge suppressors for DC cables  • A PolyPhaser DGXZ+06NFNF-A surge suppressor for the coaxial cable from the GPS antenna    Power Faults   If excessive current is drawn on a port, the analog circuitry reports a PoE fault.  The system then turns the port power off.  The power will be restored when the fault is removed.  The following illustration shows the port status screen with a power fault on port 1.
Preliminary JUL 2010     CMM4 User Guide PMP 320 Hardware Installation Configuring CMM4 ports      Figure 3-6   Port Status Showing Power Fault      Configuring CMM4 ports   To configure the ports that have been connected in this installation procedure, refer to the located at: . http://motorola.wirelessbroadbandsupport.com/software/   Other Installation Considerations   If two CMM4 devices are synchronized together, the CMM4 that does not have a GPS needs to be set up via the GUI as a CMM slave device.  Refer to the CMM4 User guide located at : . http://motorola.wirelessbroadbandsupport.com/software/
PMP320HDW2v1 3-47 JUL 2010 Preliminary     Other Installation Considerations Chapter 3: CMM4 Hardware Installation                                                                       3-26 PMP320HDW2v1
Preliminary JUL 2010     Chapter 4       Cables ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■              ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■              ■             ■             ■             ■             ■             ■              ■  ■  ■  ■  ■
PMP320HDW2v1 3-49 JUL 2010 Preliminary     DC Cables Chapter 4: Cables     DC Cables  ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■  ■  ■   Motorola recommends the use of flame-retardant, moisture and sunlight-resistant cable rated to 75° C wet and bendable at -25° C for the DC cable between the power supply(s) and the http://www ), catalog CMM4.  Examples of such cable include General Cable ( .generalcable.com number 234580 for 12 AWG cable and catalog number 236300 for 10 AWG cable, found in the Telecommunications Catalog.  Recommended wire size for the DC cable of the CMM4 in most systems is shown in Table 4-1. These wire sizes support up to 8 radios (30 VDC or 56 VDC radios) at up to 100 m (328 ft) Ethernet cable length from the CMM4.  Table 4-1   Wire size for CMM4 DC cable  DC Power Cord Length Wire Gage Up to 90 ft (3−25 m) 12 AWG (4 mm2) 91−145 ft (26−45 m) 10 AWG (6 mm2) 146−230 ft (46−70 m) 8 AWG (10 mm2)  For supporting 8 PMP 54400 APs or PTP 54200 BHs (which are 12 W 30 VDC radios), reduce either the maximum DC cable length or the Ethernet cable length by half.  For example, if the Ethernet cable length from CMM4 to 8 PMP 54400 APs is 50 m (164 ft) or less, the DC lengths in Table 4-1 can be used.  If the Ethernet cable length from CMM4 to 8 PMP 54400 APs is 100 m (328 ft), then halve the lengths shown in Table 4-1.                                  4-2 PMP320HDW2v1
4-50 PMP320HDW2v1 Preliminary JUL 2010     PMP 320 Hardware Installation Ethernet Cables     Ethernet Cables  ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■  ■  ■   The operator provides the Ethernet cables between the CMM4 and the radios it supports.  They must be engineered to length and are not included with the CMM4.  The cable length from the CMM4 to any radio must be under 100 m (328 ft).  Cables are available from Best-Tronics, Inc., http://best-tronics.com/motorola.htm.  These cables can be ordered in lengths up to 328 ft (100 m) and are listed in the following tables.  Table 4-2   Recommended Ethernet Cables  Typical Use Best-Tronics Part Number Description  Infrastructure  Ethernet cable      Infrastructure  Ethernet cable for plenums  BT-0781S-XXX RJ-45  to  RJ-45  straight, shielded,  UV-resistant Ethernet cable using outdoor STP Cat 5e cable, lower cost than plenum-rated, available only in black.  BT-0562S-XXX RJ-45  to  RJ-45  straight, shielded,  UV-resistant, plenum-rated Ethernet cable using outdoor STP Cat 5e cable,  available in beige, blue, grey, or white.   NOTE  Shielded Ethernet cable is strongly recommended for AP and BH installations.   Alternatively, equivalent cables may be procured by the operator, fabricated by the operator in a depot, or fabricated at site.  The modules have auto MDX/MDIX and so either straight-through or crossover Ethernet cables may be used.  Pinouts for straight-through cables are shown the following figures.
PMP320HDW2v1 4-51 Preliminary JUL 2010     Ethernet Cables Chapter 4: Cables      Figure 4-1   RJ-45 Straight-through connections     Table 4-3   Recommended Ethernet Cables  Pin Color  1 white / orange  2 orange  3 white / green  4 blue  5 white / blue  6 green  7 white / brown  8 brown    Figure 4-2   Pin 1 Location diagram     Lo c k    t a  b u n d e r n e a t h )   ←     P in  1    Bulk unterminated Ethernet cable can be ordered from Best-Tronics as bulk cable: • CA-0287S: (shielded, plenum rated)  • CA-0367S: (lower cost, shielded, non-plenum-rated)
4-52 PMP320HDW2v1 Preliminary JUL 2010     PMP 320 Hardware Installation CMM Sync Cable     CMM Sync Cable  ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■  ■  ■   Two CMMs (two CMMmicros, two CMM4s, or a CMMmicro and a CMM4) can be connected together with a CMM sync cable to provide either • The ability to have one GPS antenna support two CMMs  • Warm spare redundant sync  Pinouts for the CMM sync cable are shown in the following figures.  Figure 4-4 shows the location of Pin 1, relative to the lock tab on the connector.   NOTE  The CMM sync cable used to connect two CMMs for sync purposes has different pinouts than the straight-through sync cable used to connect a “remote AP” to an SM, or an AP or BHM to a CMM2.
PMP320HDW2v1 4-53 Preliminary JUL 2010     CMM Sync Cable Chapter 4: Cables      Figure 4-3   CMM sync cable pinouts      Figure 4-4   CMM sync cable pinouts     (Lock tab is on other side)   ←    Pin 1
    Chapter 5       CSM Hardware Installation ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■              ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■  ■  ■  ■  ■  This chapter provides the instructions and procedures used to: • connect the CSM device to a pole or wall  • pre-power up alignment for level of service connection  • cable the unit  • ground the unit  • add surge suppression  • post power up connection  • IP connectivity alignment correction    CAUTION  The orientation of the CSM when installed is important.  The face of the CSM with the Motorola logo must be pointing in the direction of the antenna facing outwards from the building.  The Ethernet connector must be oriented so it is on the bottom right corner of the CSM.    Figure 5-1   CSM (CPE) 320 Identification  Canopy  CSM 320                  Ethernet Connector Front Rear   PMP320HDW2v1 5-1 JUL 2010 Preliminary
5-2 PMP320HDW2v1 Preliminary JUL 2010     Before you begin Chapter 5: CSM Hardware Installation     Before you begin  ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■  ■  ■   This section describes items that the installer or subscriber must purchase before installing the CSM. This section also describes items that must be available and points to consider before beginning the CSM installation.   Additional material required for installation   The additional materials required for installation are as follows: • The computer of the subscriber must be equipped with an Ethernet network interface card (NIC).  NOTE  The NIC is not provided with the CSM, but subscribers can purchase a NIC at most computer and electronics stores.   • An RJ–45 Ethernet cable to connect the CSM plug-in power supply to the computer.  • Ground wire of sufficient length to run between the CSM and the home ground point.  NOTE   • It is recommended that the ground wire be a 6 AWG, solid copper wire. • It is recommended that if a ground rod is used it should be an 8 ft (2.5m) copper rod. • Most buildings have an existing ground rod outside, at the main power connection site.  If desired, a rod can be installed into the ground outside the building after consulting the local electrical codes. • The AC line cord is not provided with the hardware.  Acquire the appropriate power line cord for the country where the unit is installed.   • Lead screw anchors if the CSM is mounted on a brick or masonry surface.  • Outdoor-rated category 5e Ethernet cable to connect the CSM plug-in power supply through the building wall to the CSM.  • RJ–45 plug connectors and the tools required for field termination of the category 5e cable  • Grommet to cover a 3/4 inch.  (18 mm) hole  • Silicone or acrylic caulking
PMP320HDW2v1 5-3 Preliminary JUL 2010     PMP 320 Hardware Installation Pre-installation planning      Pre-installation planning   While on the ground, find an appropriate location outside the building to mount the CSM.   NOTE  To provide Internet service, the CSM communicates with a base station on the communications tower of the service provider.  Information about the nearest communications tower is provided by the service provider.  For example, if the tower nearest to the building is towards the north of the building, install the CSM on the north side of the building.   After determining the optimal side of the building, select an CSM mounting point at a high location is unlikely to be touched by user/passer on the building such as under the eaves.   Components shipped with the CSM   Locate the components shipped with the CSM device.  The parts list for the CSM installation consists of the following items:  Table 5-1   CSM parts list  Component  Quantity  CSM 320 device (vertical) 1  Bracket base mounting 1  Bracket Bottom Mounting 1  Bracket Top Mounting 1  Middle mounting bracket 1  M8 (50 mm) hex head bolt 2  M8 (100 mm) bolt 2  M8 split washer 13  M8 washer 11  M8 nut 3  M5 (35 mm) set screw 2  M4 (16 mm) bolt 4  M4 split washer 4  M4 washer 4  Dsign power supply 1  ENET cable 1
5-4 PMP320HDW2v1 Preliminary JUL 2010     Cabling Overview Chapter 5: CSM Hardware Installation      Figure 5-2   CSM components   CSM320 M8 x 50 MM Bolt M8 Split Washer M8 Washer  M5 Set Screw 35MM M8 Split Washer  M5 Set Screw 35MM M8 Split Washer    M8 x 50 MM Bolt M8 Split Washer M8 Washer  Bracket Bottom Mounting Bracket Top Mounting   Bracket Base Mounting      4X M4 x 16MM Bolt 4X M4 Split Washer 4X M4 Washer M8 Nut Middle Mounting bracket 2X M8 Nut 4X M8 Split Washer 4X M8 Washer M8 Split Washer M8 Washer   2X M8 x 100 MM Bolt  Mounting Pole (Reference)    Cabling Overview   The following items are not supplied with the system: • Ground wire  • Grounding rod  • Outdoor power/Ethernet cable  • Ethernet cable  • Computer NIC  Figure 6-4 illustrates the routing of the ground wire, the category 5e Ethernet cable, and the CSM power/Ethernet cable.
PMP320HDW2v1 5-5 Preliminary JUL 2010     Building’s wall PMP 320 Hardware Installation Cabling Overview      Figure 5-3   CSM mounted to a wall      Building’s Roof    CPE Bracket assembly attached to building's exterior    Subscriber’s Computer  CPE Power/Ethernet cable   Dsine         Surge Suppressor      Ethernet cable (not supplied) Ground wire (not supplied)  to household grounding point
5-6 PMP320HDW2v1 Preliminary JUL 2010     1 Using a laptop and a temporary power source connected to the CSM locate the optimal site for the CSM to be installed.  Refer to the PMP 320  Administration  and  Configuration  Guide  for  additional information  on  accessing  the  CSM  GUI  and  status  settings. htt// t l i l b db d t / t/lib /? i 1& t2 Start by pointing the front of the CSM in the direction that is most likely to be optimal. 3 Try pointing the CSM in different directions.  If required, perform this task while standing in the upper stories or on the roof of the building.  At each elevation and in each direction the CSM is pointed. 4 After determining the place where the best signal can be detected using the CSM GUI screen information, choose a corresponding CSM installation location on the building.  NOTE  The CSM can be mounted either directly on the building or on a pole. Installing the CSM Chapter 5: CSM Hardware Installation     Installing the CSM  ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■  ■  ■   This section describes how to find an appropriate installation location for the CSM, and how to install the CSM on the building.   Selecting a location for the CSM   Determine the optimum installation location for the CSM before physically mounting the CSM to the building.  Most often, if the CSM is mounted on the side of the building facing the base station of the service provider, the CSM can detect adequate signal to provide high-speed Internet access. However, unless there is an obvious line of sight to the correct base station, the correct orientation of the CSM is often not apparent.  There may also be practical reasons why the CSM cannot be mounted on the side of the building that faces the base station.   Procedure 5-1   Selecting an installation location for the CSM        =8
PMP320HDW2v1 5-7 Preliminary JUL 2010     PMP 320 Hardware Installation Installation Overview     Installation Overview  ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■              ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■              ■             ■             ■             ■             ■             ■             ■  ■  ■   After finding the best installation location on the building, perform the following procedure to install the CSM.   Procedure 5-2   Installing the CSM   1 Complete the mounting bracket assembly; leave the screws on the bracket arm slightly loose.  If the screws are too tight, the vertical and horizontal tilt of the CSM cannot be adjusted later.  NOTE  If fastening the CSM to a pole, add the pole clamp to the assembly. Otherwise, set the pole clamp aside. 2 Perform one of the following:  1. If attaching the CSM to the side of a building, attach the CSM to the building using the wall bracket of the bracket assembly.  2. Mount the CSM to a pole using the wall bracket and pole clamp of the bracket assembly. 3 Adjust the vertical and horizontal tilt of the CSM so that it can obtain the best signal. 4 Fully tighten the bracket assembly into the desired position.    Completing the mounting bracket assembly   Perform the following procedure to complete the mounting bracket assembly.  Refer to Figure 6-3 to reference the brackets and the assembly of the brackets.   Procedure 5-3   Mounting bracket assembly   1 Attach one end of the bracket arm to the arch on this wall bracket. 2 Insert a 5/16×1½ hex bolt into the arch of the wall bracket that was attached to the CSM in step 1.  Ensure that the head of the medium hex bolt rests inside the bolt jam of the arch. 3 Guide the rest of the bolt through the arch of the wall bracket. 4 Slide a tooth lock washer on the end of the hex bolt. 5 Align the hole on one tab of the bracket arm with the end of the bolt.  Continued
5-8 PMP320HDW2v1 Preliminary JUL 2010     Attaching the CSM and mounting the bracket assembly outside the building Chapter 5: CSM Hardware Installation      Procedure 5-3   Mounting bracket assembly (Continued) 6 Slide the bracket arm tab onto the bolt, and then place a flat washer over the end of the bolt. 7 Tighten the end of the bolt with a hex nut.  Leave the hex nut loose enough so that the vertical tilt of the CSM can be adjusted later. 8 Attach the other end of the bracket arm to the second wall bracket. 9 Insert a 5/16×1½ hex bolt into the arch of the second wall bracket.  This bracket is attached to the wall or clamped to a pole.  NOTE  Ensure that the head of the hex bolt rests inside the bolt jam found on the arch.  When the assembly is complete, ensure that the bolt jam is facing the ground. 10 Guide the rest of the bolt through the arch of the wall bracket. 11 Slide a tooth lock washer at the end of the hex bolt. 12 Align the hole on the tab of the bracket arm with the end of the bolt. 13 Slide the tab of the bracket arm onto the bolt, and then place a flat washer over the end of the bolt. 14 Tighten the end of the bolt with a hex nut.  Leave the hex nut loose enough so that the horizontal tilt of the CSM can be adjusted later. 15 If fastening the CSM to a pole, loosely attach the clamp to wall bracket 2. Perform the steps listed in the section Fastening the CSM and mounting the bracket assembly to a pole.     Attaching the CSM and mounting the bracket assembly outside the building    WARNING  Maintain a safe distance from RF exposure at least 120 cm when installing the CSM to the subscriber building. Maintain safe distances from power lines.   Perform the following procedure to attach the CSM to the outside of the building.
PMP320HDW2v1 5-9 Preliminary JUL 2010     PMP 320 Hardware Installation Fastening the CSM and mounting the bracket assembly to a pole       Procedure 5-4   Attaching the CSM and mounting the bracket assembly outside the building   1 Where possible, install the CSM on the side of the building that has the greatest exposure to the communications tower of the service provider.  The service provider can provide information about tower locations that can provide the CSM with the greatest signal exposure. 2 Drill holes into the exterior wall of the building where the CSM must be hung. • Drill the two top holes 2.5 inches apart.  Drill the bottom holes 2.5 inches below the top holes.  • If possible, drill one upper hole and its corresponding lower hole into a stud. Do not allow the CSM to be supported by the siding of the building. • If installing the CSM on a brick or masonry surface, use appropriate anchors.   CAUTION  Observe caution when drilling through the wall of the building. Ensurethat there are no power lines, gas lines, water lines, or data lines in the wall at the desired location where the drilling takes place. 3 After the holes are drilled into the building, drive the screws through the holes on the wall bracket and into the building.  While attaching the bracket assembly to the wall, ensure that the bottom of the CSM is pointing towards the ground.  The bottom of the CSM is the side with the five lights and the grounding lug.  The CSM must be installed vertically.    Fastening the CSM and mounting the bracket assembly to a pole   If fastening the CSM to a pole, add the pole clamp to the assembly.  Perform the following procedure to fasten the CSM to a pole.   Procedure 5-5   Fastening the CSM and mounting the bracket assembly to a pole   1 Insert the following through the holes on the clamp:  • Large hex bolt  • Large split washer  • Large washer 2 Place the clamp around the pole. 3 Align the screw assembly with the center holes on the wall bracket. 4 Tighten the clamp so that the bracket assembly and the attached CSM are tight on the pole.
5-10 PMP320HDW2v1 Preliminary JUL 2010     1 Temporarily apply power to the CSM to adjust the CSM for signal strength.  NOTE  Do not connect to the consumer computer at this time.  The AC line cord is not provided with the hardware.  Acquire the appropriate power line cord for the country where the unit is installed. 2 Connect an Ethernet cable to the CSM and to a laptop. 3 Log into the CSM GUI application to view the status of the signal strength of the CSM unit.  Enter the following default user name and password IDs:  • Login ID - operator  • Password - wimax 4  Aligning the CSM for best signal strength Chapter 5: CSM Hardware Installation     Aligning the CSM for best signal strength  ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■             ■             ■             ■             ■             ■  ■  ■    NOTE  This alignment procedure assumes that the installer has reviewed the site interference values collected for the area of the installation.   The bolts connecting the two pole/wall brackets to the bracket arm are not yet fully tightened. Hence, use the bracket arm to adjust the vertical and horizontal tilt of the CSM. This adjustment helps the CSM to obtain the strongest signal from the service provider.  Perform the following procedure to adjust the vertical and horizontal tilts of the CSM.   Procedure 5-6   Adjusting the vertical and horizontal tilt of the CSM for level of service connection                     Adjust the CSM by rotating the CSM to the left and right.  Find the position of the CSM where the CSM GUI indicates the strongest signal strength to the unit.  Verify the signal strength on the status page of the CSM GUI screen.  Continued
PMP320HDW2v1 5-11 Preliminary JUL 2010     PMP 320 Hardware Installation Aligning the CSM for best signal strength      Procedure 5-6   Adjusting the vertical and horizontal tilt of the CSM for level of service connection (Continued)                           5 After finding the strongest signal from the service provider, tighten all the bolts on the mounting bracket assembly.  Once the screws are tightened, the CSM will no longer move sideways, nor up and down. 6 Log out of the CSM GUI once optimal signal strength is achieved.   After completing the alignment and mounting of the CSM on the outside of the building, proceed with the installation procedures for the subscriber Ethernet, surge suppression, and unit Earth Grounding procedures.
5-12 PMP320HDW2v1 Preliminary JUL 2010     Connecting the CSM to the Ethernet cable, Earth Ground, the Surge Suppressor Chapter 5: CSM Hardware Installation     Connecting the CSM to the Ethernet cable, Earth Ground, the Surge Suppressor  ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■  ■  ■    Ethernet Cable Assembly   Before installing the CSM Ethernet cable, ensure that the Ethernet cable is constructed with the weather protection kit that is contained with the CSM device.  Use Figure 6-6 to construct the weather protection housing around the Ethernet cable and RJ-45 plug.  This weatherized cable connects to the ENET connector of the CSM.   Figure 5-4   Ethernet cable weather protection assembly   1   Strip cable sheath. 2   Insert the screw nut into the housing. 3   Insert the seal at the back end of the housing.   7.7    Recommended wire Gauge: 24AWG  Screw Nut Seal   4   Insert the cable all the way through.        Cable 5   Crimp the RJ45 plug.        Crimp the RJ45 plug 6   Insert the plug into the housing. Then secure the sealing nut in place.       Plug   7   Strick the gasket on the front end of the housing.   Seal Parts Identification   RJ45 Plug    Gasket   Screw Nut Screw Nut Housing Gasket     Perform the following procedure to connect the Ethernet/power cable to the CSM.
PMP320HDW2v1 5-13 Preliminary JUL 2010     PMP 320 Hardware Installation Ethernet Cable Assembly       Procedure 5-7   Connecting the Ethernet cable to the CSM  1 Cut the required length of the outdoor-rated Category-5 Ethernet cable for the chosen installation site.  The maximum cable length is 100 m (~330 ft). 2 Terminate the cable using standard RJ–45 connectors using the procedure as shown in Figure 6-6.  Use dielectric grease (which is uniformly non-conducting) on all connections and in all RJ–45 Ethernet connectors.  The best practice is to use enough grease to fill the RJ–45 female connector, and then insert the RJ-45 male connector and push the grease further into the unit and around the RJ–45 connector.  Excess grease can be wiped over the connector area to provide some resistance to water ingress around the connector. 3 Wrap a drip-loop in the cable at any point where the cable changes direction. 4 Measure the cable so it will span from the CSM to the surge suppressor box. 5 Fasten the cable to the building according to local building codes.  NOTE  Cables that move in the wind can be damaged, impart vibrations to the connected device, or both.  At installation time, prevent these problems by securing all cables with cable ties, cleats, or weather resistant tape.  The cable can be a path for water to follow to enter the cable connector or even the module.  Prevent this problem by including and securing a drip loop where the cable enters the building.           Note: "Please select antenna cables suitable for outdoor communication system according to the   requirements of NFPA 70, National Electrical Code, 830.179."
5-14 PMP320HDW2v1 Preliminary JUL 2010     Running cables through the wall of the building Chapter 5: CSM Hardware Installation     Running cables through the wall of the building  ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■  ■  ■   The power/Ethernet cable runs from inside the building to the CSM. The following procedure describes how to run the cables through the wall of the building.   CAUTION  Observe caution when drilling through the wall of the building. Ensure that there are no power lines, gas lines, water lines, or data lines in the wall at the desired location where the drilling takes place.    Procedure 5-8   Running cables through the wall of the building   1   CAUTION  Follow local building codes for penetrating buildings.  Observe caution when drilling through the wall of the building. Ensure that there are no power lines, gas lines, water lines, or data lines in the wall at the desired location.  Drill a 3/4 inch.  (18 mm) hole through the wall at the desired location. 2 Draw one end of the category 5e cable through the hole. 3 Route the category 5e power/Ethernet cable from the surge suppressor to the location where the power supply is to be plugged in. 4 After completing the installation, use a grommet for the hole and seal the hole with a silicone or acrylic caulking material.
PMP320HDW2v1 5-15 Preliminary JUL 2010     PMP 320 Hardware Installation Installing the 600SSD Surge Suppressor     Installing the 600SSD Surge Suppressor  ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■              ■               ■             ■             ■             ■              ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■  ■  ■   Use the following procedure to install the 600SSD Surge suppressor.   CAUTION  Observe caution when drilling through the wall of the building. Ensure that there are no power lines, gas lines, water lines, or data lines in the wall at the desired location where the drilling takes place.    Procedure 5-9   Installing the 600SSD Surge Suppressor   1 With the cable openings facing downward, install the 600SSD surge suppressor above the site where the hole in the residence has been drilled. Use two screws to attach the unit following regulatory building guidelines. 2 Connect the surge suppressor to Earth Ground.  Refer to Connecting the CSM to the Ethernet cable, Earth Ground, the Surge Suppressor on page 6-13.  Refer to Figure 6-7. 3 Pack both of the 600SSD surge suppressor Ethernet jacks with dielectric grease. 4 Include a splicing loop in the Ethernet cable from the CSM (extra cable to allow future repositioning or reconnectorization) and position and secure the Ethernet cable with UV-resistant wire ties or other locally-approved fasteners so it forms a drip loop (so water drips off the cable instead of following the cable into the 600SSD surge suppressor). 5 Connect the Ethernet connection from the CSM to the surge suppressor. 6 Build another Ethernet cable to span from the surge suppressor through the residence wall to the area where the power injector will be placed in the subscriber’s residence. 7 Guide the Ethernet cable through the grommet where the drilled hole was made into the residence. 8 Seal the cable entry point into the building using accepted industry or local practices. 9 Connect the Ethernet cable to the Data In port of the CSM power injector. Refer to Figure 6-8.
5-16 PMP320HDW2v1 Preliminary JUL 2010     Connecting the ground wire Chapter 5: CSM Hardware Installation      Figure 5-5   Cable connections from the surge suppressor to the CSM power injector and the CSM    Surge Suppressor            All cables must exit through the allocated slots          Figure 5-6   CSM 320 power injector         AC POWER    DATA & POWER    DATA OUT IN  PORT  AC      Connecting the ground wire   The CSM must be grounded to a household ground point or to a grounding rod according to the applicable electrical code.  Equipment grounding practices vary with local building codes and established practices of the service provider.  Following is the CSM grounding procedure as recommended by Motorola.  The ground wire must be a minimum of 18 AWG, with 14 AWG recommended for runs up to 45 m (~150 ft) and 10 AWG recommended for runs over 45 m (~150 ft) .
PMP320HDW2v1 5-17 Preliminary JUL 2010     PMP 320 Hardware Installation Connecting the power supply and the Ethernet cable to the computer      NOTE  If not using an existing approved grounding system, install a grounding system (Protective Earth) according to applicable regulations or codes.   Ground the CSM using one of the following methods: • If grounding a CSM installed below the roof line, connect the CSM to the ground point of the building and then attach all wires to the building using electrical staples.  Use drip loops as required.  • If grounding an CSM that is installed above the roof line, then perform the following: Connect the ground wire from the CSM/surge suppressor to the ground rod in the ground next to the building.  Connect the ground rod to the household ground point according to the applicable electrical code.  Attach all wires to the building using electrical staples.  Use drip loops as required.   Use the following procedure to ground the CSM at the residence premises.   Procedure 5-10   Grounding the CSM   1 Wrap the AWG 10 (6mm2) copper ground wire around the ground post of the CSM. 2 Remove the cover of the 600SSD surge suppressor. 3 Wrap the AWG 10 (6mm2) copper ground wire around the ground post of the 600SSD. 4 Tighten the ground post locking nut. 5 Ensure the pin 4 selector in the 600SSD is set to the factory default of isolated, not grounded. 6 If not using an existing approved grounding system, install a grounding system (Protective Earth) according to applicable regulations or codes. 7 Connect the ground wire from the CSM and the 600SS to Earth Ground.    Connecting the power supply and the Ethernet cable to the computer   Perform the following procedure to connect the power supply and the Ethernet cables.
5-18 PMP320HDW2v1 Preliminary JUL 2010     Connecting the power supply and the Ethernet cable to the computer Chapter 5: CSM Hardware Installation       Procedure 5-11   Connecting the power supply   1 Plug the category 5e cord from the CSM/surge suppressor into the jack labeledAC Power on the CSM Power Injector (if this connection is not already made).2 Connect the protected side of the 600SSD surge suppressor cable to the Data& Power Out port of the CSM power injector. 3 Use a standard category 5e Ethernet cable to connect the computer to the jack labeled computer on the power supply.  NOTE  The cable to the CSM provides both power and Ethernet connection.It is not pin or voltage compatible with IEE std.802.3af-2003 power over Ethernet. 4 The power cord uses standard household power.  Plug the power cord in the AC power source.  NOTE  The AC line cord is not provided with the hardware.  Acquire the appropriate power line cord for the country where the unit is installed.   Figure 6-8 illustrates the cable connection through the data line protector and into the power supply cord.
    Chapter 6      Connectorized CSM Hardware Installation ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■              ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■              ■             ■             ■             ■             ■             ■             ■  ■  ■  ■  ■  This chapter provides the instructions and procedures used to: • connect the Connectorized CSM device to a pole or wall  • pre-power up alignment for level of service connection  • cable the unit  • connect the antenna cables to the unit  • ground the unit  • add surge suppression  • post power up connection  • IP connectivity alignment correction    CAUTION  The orientation of the CSM when installed is important.  The face of the CSM with the Motorola logo must be pointing in the direction of the antenna facing outwards from the building.  The Ethernet connector must be oriented so it is on the bottom right corner of the Connectorized CSM.                          PMP320HDW2v1 6-1 JUL 2010 Preliminary
6-2 PMP320HDW2v1 Preliminary JUL 2010     Connecting the power supply and the Ethernet cable to the computer  Chapter 6: Connectorized CSM Hardware Installation      Figure 6-1   Connectorized CSM (CPE) 320 Identification           G1_CCSMfrtpanelview.eps    Figure 6-2   Connectorized CSM (CPE) 320 Rear View Connectors    G1_CCSM_rearviewconn.ext
PMP320HDW2v1 6-3 Preliminary JUL 2010     PMP 320 Hardware Installation Before you begin     Before you begin  ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■  ■  ■   This section describes items that the installer or subscriber must purchase before installing the CSM. This section also describes items that must be available and points to consider before beginning the CSM installation.   Additional material required for installation   The additional materials required for installation are as follows: • The computer of the subscriber must be equipped with an Ethernet network interface card (NIC).  NOTE  The NIC is not provided with the CSM, but subscribers can purchase a NIC at most computer and electronics stores.   • An RJ–45 Ethernet cable to connect the CSM plug-in power supply to the computer.  • Ground wire of sufficient length to run between the CSM and the home ground point.  NOTE   • It is recommended that the ground wire be a 6 AWG, solid copper wire. • It is recommended that if a ground rod is used it should be an 8 ft (2.5m) copper rod. • Most buildings have an existing ground rod outside, at the main power connection site.  If desired, a rod can be installed into the ground outside the building after consulting the local electrical codes. • The AC line cord is not provided with the hardware.  Acquire the appropriate power line cord for the country where the unit is installed.   • Lead screw anchors if the CSM is mounted on a brick or masonry surface.  • Outdoor-rated category 5e Ethernet cable to connect the CSM plug-in power supply through the building wall to the CSM.  • RJ–45 plug connectors and the tools required for field termination of the category 5e cable  • Grommet to cover a 3/4 inch.  (18 mm) hole  • Silicone or acrylic caulking
6-4 PMP320HDW2v1 Preliminary JUL 2010     Pre-installation planning Chapter 6: Connectorized CSM Hardware Installation      Pre-installation planning   While on the ground, find an appropriate location outside the building to mount the CSM.   NOTE  To provide Internet service, the CSM communicates with a base station on the communications tower of the service provider.  Information about the nearest communications tower is provided by the service provider.  For example, if the tower nearest to the building is towards the north of the building, install the CSM on the north side of the building.   After determining the optimal side of the building, select an CSM mounting point at a high location on the building such as under the eaves.   Components shipped with the CSM   Locate the components shipped with the CSM device.  The parts list for the CSM installation consists of the following items:  Table 6-1   CSM parts list  Component  Quantity  CSM 320 device 1  Bracket base mounting 1  Bracket Bottom Mounting 1  Bracket Top Mounting 1  Middle mounting bracket 1  M8 (50 mm) hex head bolt 2  M8 (100 mm) bolt 2  M8 split washer 13  M8 washer 11  M8 nut 3  M5 (35 mm) set screw 2  M4 (16 mm) bolt 4  M4 split washer 4  M4 washer 4  Dsign power supply 1  ENET cable 1
PMP320HDW2v1 6-5 Preliminary JUL 2010     PMP 320 Hardware Installation Cabling Overview      Figure 6-3   CSM components  CSM320  M8 x 50 MM Bolt M8 Split Washer M8 Washer  M5 Set Screw 35MM M8 Split Washer   M5 Set Screw 35MM M8 Split Washer   M8 x 50 MM Bolt M8 Split Washer M8 Washer     Bracket Base Mounting  Bracket Bottom Mounting Bracket Top Mounting      4X M4 x 16MM Bolt 4X M4 Split Washer 4X M4 Washer   M8 Nut M8 Split Washer M8 Washer    Middle Mounting bracket    2X M8 x 100 MM Bolt   2X M8 Nut 4X M8 Split Washer 4X M8 Washer   Mounting Pole (Reference)     Cabling Overview   The following items are not supplied with the system: • Ground wire  • Grounding rod  • Outdoor power/Ethernet cable  • Ethernet cable  • Computer NIC  Figure 6-4 illustrates the routing of the ground wire, the category 5e Ethernet cable, and the CSM power/Ethernet cable.
6-6 PMP320HDW2v1 Preliminary JUL 2010     Building’s wall Cabling Overview Chapter 6: Connectorized CSM Hardware Installation      Figure 6-4   CSM mounted to a wall      Building’s Roof   CPE Bracket assembly attached to building's exterior Connectorized CSM *antenna not shown    Subscriber’s Computer CPE Power/Ethernet cable   Dsine    CPE Bracket assembly attached to building's exterior   Surge Suppressor      Ethernet cable (not supplied) Ground wire (not supplied)  to household grounding point
PMP320HDW2v1 6-7 Preliminary JUL 2010     1 Using a laptop and a temporary power source connected to the CSM locate the optimal site for the CSM to be installed.  Refer to the PMP 320  Administration  and  Configuration  Guide  for  additional information  on  accessing  the  CSM  GUI  and  status  settings. htt // t l i l b db d t / t/lib /? i 1& t2 Start by pointing the front of the CSM in the direction that is most likely to be optimal. 3 Try pointing the CSM in different directions.  If required, perform this task while standing in the upper stories or on the roof of the building.  At each elevation and in each direction the CSM is pointed. 4 After determining the place where the best signal can be detected using the CSM GUI screen information, choose a corresponding CSM installation location on the building.  NOTE  The CSM can be mounted either directly on the building or on a pole. PMP 320 Hardware Installation Installing the CSM     Installing the CSM  ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■  ■  ■   This section describes how to find an appropriate installation location for the CSM, and how to install the CSM on the building.   Selecting a location for the CSM   Determine the optimum installation location for the CSM before physically mounting the CSM to the building.  Most often, if the CSM is mounted on the side of the building facing the base station of the service provider, the CSM can detect adequate signal to provide high-speed Internet access. However, unless there is an obvious line of sight to the correct base station, the correct orientation of the CSM is often not apparent.  There may also be practical reasons why the CSM cannot be mounted on the side of the building that faces the base station.   Procedure 6-1   Selecting an installation location for the CSM        =8
6-8 PMP320HDW2v1 Preliminary JUL 2010     Installation Overview Chapter 6: Connectorized CSM Hardware Installation     Installation Overview  ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■  ■  ■   After finding the best installation location on the building, perform the following procedure to install the CSM.   Procedure 6-2   Installing the Connectorized CSM   1 Complete the mounting bracket assembly; leave the screws on the bracket arm slightly loose.  If the screws are too tight, the vertical and horizontal tilt of the CSM cannot be adjusted later.  NOTE  If fastening the CSM to a pole, add the pole clamp to the assembly. Otherwise, set the pole clamp aside. 2 Perform one of the following:  1. If attaching the CSM to the side of a building, attach the CSM to the building using the wall bracket of the bracket assembly.  2. Mount the CSM to a pole using the wall bracket and pole clamp of the bracket assembly. 3 Adjust the vertical and horizontal tilt of the CSM so that it can obtain the best signal. 4 Fully tighten the bracket assembly into the desired position.    Completing the mounting bracket assembly   Perform the following procedure to complete the mounting bracket assembly.  Refer to Figure 6-3 to reference the brackets and the assembly of the brackets.   Procedure 6-3   Mounting bracket assembly   1 Attach one end of the bracket arm to the arch on this wall bracket. 2 Insert a 5/16×1½ hex bolt into the arch of the wall bracket that was attached to the CSM in step 1.  Ensure that the head of the medium hex bolt rests inside the bolt jam of the arch. 3 Guide the rest of the bolt through the arch of the wall bracket. 4 Slide a tooth lock washer on the end of the hex bolt. 5 Align the hole on one tab of the bracket arm with the end of the bolt.  Continued
PMP320HDW2v1 6-9 Preliminary JUL 2010     PMP 320 Hardware Installation Attaching the CSM and mounting the bracket assembly outside the building      Procedure 6-3   Mounting bracket assembly (Continued) 6 Slide the bracket arm tab onto the bolt, and then place a flat washer over the end of the bolt. 7 Tighten the end of the bolt with a hex nut.  Leave the hex nut loose enough so that the vertical tilt of the CSM can be adjusted later. 8 Attach the other end of the bracket arm to the second wall bracket. 9 Insert a 5/16×1½ hex bolt into the arch of the second wall bracket.  This bracket is attached to the wall or clamped to a pole.  NOTE  Ensure that the head of the hex bolt rests inside the bolt jam found on the arch.  When the assembly is complete, ensure that the bolt jam is facing the ground. 10 Guide the rest of the bolt through the arch of the wall bracket. 11 Slide a tooth lock washer at the end of the hex bolt. 12 Align the hole on the tab of the bracket arm with the end of the bolt. 13 Slide the tab of the bracket arm onto the bolt, and then place a flat washer over the end of the bolt. 14 Tighten the end of the bolt with a hex nut.  Leave the hex nut loose enough so that the horizontal tilt of the CSM can be adjusted later. 15 If fastening the CSM to a pole, loosely attach the clamp to wall bracket 2. Perform the steps listed in the section Fastening the CSM and mounting the bracket assembly to a pole.     Attaching the CSM and mounting the bracket assembly outside the building    WARNING  Maintain a safe distance from RF exposure at least 120 cm when installing the CSM to the subscriber building. Maintain safe distances from power lines.   Perform the following procedure to attach the CSM to the outside of the building.
6-10 PMP320HDW2v1 Preliminary JUL 2010     Fastening the CSM and mounting the bracket assembly to a pole Chapter 6: Connectorized CSM Hardware Installation       Procedure 6-4   Attaching the CSM and mounting the bracket assembly outside the building   1 Where possible, install the CSM on the side of the building that has the greatest exposure to the communications tower of the service provider.  The service provider can provide information about tower locations that can provide the CSM with the greatest signal exposure. 2 Drill holes into the exterior wall of the building where the CSM must be hung. • Drill the two top holes 2.5 inches apart.  Drill the bottom holes 2.5 inches below the top holes.  • If possible, drill one upper hole and its corresponding lower hole into a stud. Do not allow the CSM to be supported by the siding of the building. • If installing the CSM on a brick or masonry surface, use appropriate anchors.   CAUTION  Observe caution when drilling through the wall of the building. Ensure that there are no power lines, gas lines, water lines, or data lines in the wall at the desired location where the drilling takes place.3 After the holes are drilled into the building, drive the screws through the holes on the wall bracket and into the building.  While attaching the bracket assembly to the wall, ensure that the bottom of the CSM is pointing towards the ground.  The bottom of the CSM is the side with the five lights and the grounding lug.  The CSM must be installed vertically.    Fastening the CSM and mounting the bracket assembly to a pole   If fastening the CSM to a pole, add the pole clamp to the assembly.  Perform the following procedure to fasten the CSM to a pole.   Procedure 6-5   Fastening the CSM and mounting the bracket assembly to a pole   1 Insert the following through the holes on the clamp:  • Large hex bolt  • Large split washer  • Large washer 2 Place the clamp around the pole. 3 Align the screw assembly with the center holes on the wall bracket. 4 Tighten the clamp so that the bracket assembly and the attached CSM are tight on the pole.
PMP320HDW2v1 6-11 Preliminary JUL 2010     PMP 320 Hardware Installation Connecting the Antenna Cables to the Unit     Connecting the Antenna Cables to the Unit  ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■              ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■              ■             ■             ■             ■             ■             ■              ■  ■  ■   Use the following procedure to connect the antenna cables to the unit.  Depending upon the type of antenna used, either two omni antennas, or one diagonal polarized antenna, the connectors from the installed antennas must be connected to the Connectorized CSM unit N-type connectors.  Ensure that the cable length between the CSM and the antenna connectors is 18 inches (1 ft and 6 in).  Refer to the Chapter titled Installing Antennas for additional information regarding antenna installation procedures.   Figure 6-5   Connectorized CSM antenna cable connector location      G1_Ccsmantennaconnid.eps    Procedure 6-6   Connecting the Antenna Cables to the Connectorized CSM when using an Omni Antenna   1 Verify that the length between the CSM and the Omni antennas is 18 inches apart (1 ft and 6 in).  Refer to Figure 6-5 for cable connection location on the CSM. 2 Using a 50 ohm low loss cable with an N-type connector, connect the end of the cable from the Omni antenna connector to the CSM N-type connector. 3 Repeat step 1 for the second Omni antenna.
6-12 PMP320HDW2v1 Preliminary JUL 2010     Connecting the Antenna Cables to the Unit Chapter 6: Connectorized CSM Hardware Installation       Procedure 6-7   Connecting the Antenna Cables to the Connectorized CSM when using an Diagonal Polarized Antenna   1 Using a 50 ohm low loss cable with an N-type connector, connect the N-type connector to the V-polarity connector of the antenna to the CSM N-type connector.  Refer to Figure 6-5 for cable connection location on the CSM. 2 Using the other 50 ohm cable, connect the N-type connector to the H-polarity connector of the antenna to the CSM N-type connector.
PMP320HDW2v1 6-13 Preliminary JUL 2010     PMP 320 Hardware Installation Connecting the CSM to the Ethernet cable, Earth Ground, the Surge Suppressor     Connecting the CSM to the Ethernet cable, Earth Ground, the Surge Suppressor  ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■              ■               ■             ■             ■             ■              ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■  ■  ■    Ethernet Cable Assembly   Before installing the CSM Ethernet cable, ensure that the Ethernet cable is constructed with the weather protection kit that is contained with the CSM device.  Use Figure 6-6 to construct the weather protection housing around the Ethernet cable and RJ-45 plug.  This weatherized cable connects to the ENET connector of the CSM.   Figure 6-6   Ethernet cable weather protection assembly   1   Strip cable sheath. 2   Insert the screw nut into the housing. 3   Insert the seal at the back end of the housing.   7.7    Recommended wire Gauge: 24AWG  Screw Nut Seal   4   Insert the cable all the way through.        Cable 5   Crimp the RJ45 plug.        Crimp the RJ45 plug 6   Insert the plug into the housing. Then secure the sealing nut in place.       Plug   7   Strick the gasket on the front end of the housing.   Seal Parts Identification   RJ45 Plug    Gasket   Screw Nut Screw Nut Housing Gasket     Perform the following procedure to connect the Ethernet/power cable to the CSM.
6-14 PMP320HDW2v1 Preliminary JUL 2010     Ethernet Cable Assembly Chapter 6: Connectorized CSM Hardware Installation       Procedure 6-8   Connecting the Ethernet cable to the CSM   1 Cut the required length of the outdoor-rated Category-5 Ethernet cable for the chosen installation site.  The maximum cable length is 100 m (~330 ft). 2 Terminate the cable using standard RJ–45 connectors using the procedure as shown in Figure 6-6.  Use dielectric grease (which is uniformly non-conducting) on all connections and in all RJ–45 Ethernet connectors.  The best practice is to use enough grease to fill the RJ–45 female connector, and then insert the RJ-45 male connector and push the grease further into the unit and around the RJ–45 connector.  Excess grease can be wiped over the connector area to provide some resistance to water ingress around the connector. 3 Wrap a drip-loop in the cable at any point where the cable changes direction. 4 Measure the cable so it will span from the CSM to the surge suppressor box. 5 Fasten the cable to the building according to local building codes.  NOTE  Cables that move in the wind can be damaged, impart vibrations to the connected device, or both.  At installation time, prevent these problems by securing all cables with cable ties, cleats, or weather resistant tape.  The cable can be a path for water to follow to enter the cable connector or even the module.  Prevent this problem by including and securing a drip loop where the cable enters the building.
PMP320HDW2v1 6-15 Preliminary JUL 2010     PMP 320 Hardware Installation Running cables through the wall of the building     Running cables through the wall of the building  ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■  ■  ■   The power/Ethernet cable runs from inside the building to the CSM. The following procedure describes how to run the cables through the wall of the building.   CAUTION  Observe caution when drilling through the wall of the building. Ensure that there are no power lines, gas lines, water lines, or data lines in the wall at the desired location where the drilling takes place.    Procedure 6-9   Running cables through the wall of the building   1   CAUTION  Follow local building codes for penetrating buildings.  Observe caution when drilling through the wall of the building. Ensure that there are no power lines, gas lines, water lines, or data lines in the wall at the desired location.  Drill a 3/4 inch.  (18 mm) hole through the wall at the desired location. 2 Draw one end of the category 5e cable through the hole. 3 Route the category 5e power/Ethernet cable from the surge suppressor to the location where the power supply is to be plugged in. 4 After completing the installation, use a grommet for the hole and seal the hole with a silicone or acrylic caulking material.
6-16 PMP320HDW2v1 Preliminary JUL 2010     Installing the 600SSD Surge Suppressor Chapter 6: Connectorized CSM Hardware Installation     Installing the 600SSD Surge Suppressor  ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■  ■  ■   Use the following procedure to install the 600SSD Surge suppressor.   CAUTION  Observe caution when drilling through the wall of the building. Ensure that there are no power lines, gas lines, water lines, or data lines in the wall at the desired location where the drilling takes place.    Procedure 6-10   Installing the 600SSD Surge Suppressor   1 With the cable openings facing downward, install the 600SSD surge suppressor above the site where the hole in the residence has been drilled. Use two screws to attach the unit following regulatory building guidelines. 2 Connect the surge suppressor to Earth Ground.  Refer to Connecting the CSM to the Ethernet cable, Earth Ground, the Surge Suppressor on page 6-13.  Refer to Figure 6-7. 3 Pack both of the 600SSD surge suppressor Ethernet jacks with dielectric grease. 4 Include a splicing loop in the Ethernet cable from the CSM (extra cable to allow future repositioning or reconnectorization) and position and secure the Ethernet cable with UV-resistant wire ties or other locally-approved fasteners so it forms a drip loop (so water drips off the cable instead of following the cable into the 600SSD surge suppressor). 5 Connect the Ethernet connection from the CSM to the surge suppressor. 6 Build another Ethernet cable to span from the surge suppressor through the residence wall to the area where the power injector will be placed in the subscriber’s residence. 7 Guide the Ethernet cable through the grommet where the drilled hole was made into the residence. 8 Seal the cable entry point into the building using accepted industry or local practices. 9 Connect the Ethernet cable to the Data In port of the CSM power injector. Refer to Figure 6-8.
PMP320HDW2v1 6-17 Preliminary JUL 2010     PMP 320 Hardware Installation Connecting the ground wire      Figure 6-7   Cable connections from the surge suppressor to the CSM power injector and the CSM    Surge Suppressor            All cables must exit through the allocated slots          Figure 6-8   CSM 320 power injector         AC POWER    DATA & POWER    DATA OUT IN  PORT  AC      Connecting the ground wire   The CSM must be grounded to a household ground point or to a grounding rod according to the applicable electrical code.  Equipment grounding practices vary with local building codes and established practices of the service provider.  Following is the CSM grounding procedure as recommended by Motorola.  The ground wire must be a minimum of 18 AWG, with 14 AWG recommended for runs up to 45 m (~150 ft) and 10 AWG recommended for runs over 45 m (~150 ft) .
6-18 PMP320HDW2v1 Preliminary JUL 2010     Connecting the power supply and the Ethernet cable to the computer  Chapter 6: Connectorized CSM Hardware Installation      NOTE  If not using an existing approved grounding system, install a grounding system (Protective Earth) according to applicable regulations or codes.   Ground the CSM using one of the following methods: • If grounding a CSM installed below the roof line, connect the CSM to the ground point of the building and then attach all wires to the building using electrical staples.  Use drip loops as required.  • If grounding an CSM that is installed above the roof line, then perform the following: Connect the ground wire from the CSM/surge suppressor to the ground rod in the ground next to the building.  Connect the ground rod to the household ground point according to the applicable electrical code.  Attach all wires to the building using electrical staples.  Use drip loops as required.   Use the following procedure to ground the CSM at the residence premises.   Procedure 6-11   Grounding the CSM   1 Wrap the AWG 10 (6mm2) copper ground wire around the ground post of the CSM. 2 Remove the cover of the 600SSD surge suppressor. 3 Wrap the AWG 10 (6mm2) copper ground wire around the ground post of the 600SSD. 4 Tighten the ground post locking nut. 5 Ensure the pin 4 selector in the 600SSD is set to the factory default of isolated, not grounded. 6 If not using an existing approved grounding system, install a grounding system (Protective Earth) according to applicable regulations or codes. 7 Connect the ground wire from the CSM and the 600SS to Earth Ground.    Connecting the power supply and the Ethernet cable to the computer   Perform the following procedure to connect the power supply and the Ethernet cables.
JUL 2010 Preliminary     PMP 320 Hardware Installation Connecting the power supply and the Ethernet cable to the computer       Procedure 6-12   Connecting the power supply   1 Plug the category 5e cord from the CSM/surge suppressor into the jack labeledAC Power on the CSM Power Injector (if this connection is not already made).2 Connect the protected side of the 600SSD surge suppressor cable to the Data& Power Out port of the CSM power injector. 3 Use a standard category 5e Ethernet cable to connect the computer to the jack labeled computer on the power supply.  NOTE  The cable to the CSM provides both power and Ethernet connection.It is not pin or voltage compatible with IEE std.802.3af-2003 power over Ethernet. 4 The power cord uses standard household power.  Plug the power cord in the AC power source.  NOTE  The AC line cord is not provided with the hardware.  Acquire the appropriate power line cord for the country where the unit is installed.   Figure 6-8 illustrates the cable connection through the data line protector and into the power supply cord.                                 PMP320HDW2v1 6-19
Preliminary JUL 2010     Connecting the power supply and the Ethernet cable to the computer  Chapter 6: Connectorized CSM Hardware Installation                                                                       6-20 PMP320HDW2v1
JUL 2010 Preliminary     Chapter 7      Connectorized CSM Antenna Installation Instructions ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■  ■  ■  ■  ■                                                   PMP320HDW2v1 7-1
Preliminary JUL 2010     Antenna Types used with the Connectorized CSM Chapter 7: Connectorized CSM Antenna Installation Instructions     Antenna Types used with the Connectorized CSM  ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■              ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■              ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■  ■  ■   There are two antenna types that have been tested with the Connectorized CSM PMP 320 product.  The antennas that have been tested are as follows:  • 3.3-3.8 GHz Dual Polarization/ Dual Slant Subscriber Antenna  • 3.3-3.8 GHz Omni Directional Base Station Antenna  This section provides installation procedures for both types of antennas.   Dual Polarization/Dual Slant Subscriber Antenna   The Dual Polarization Dual Slant antenna features dual slant when it is mounted diagonally.  It also offers:  • stable performance with 22 dBi of gain  • compact size allowing easy blending in any environment  • mount hardware that allows for quick and easy 45 degree turn installation  • UV protected radome suitable for harsh environments    Figure 7-1   Dual Polarization/Dual Slant Subscriber Antenna      G1diaganttccsml.eps      7-2 PMP320HDW2v1
PMP320HDW2v1 7-23 Preliminary JUL 2010     PMP 320 Hardware Installation Dual Polarization/Dual Slant Subscriber Antenna      Specifications  The Dual Polarized / Dual Slant Subscriber Antenna is produced with the following specifications:  Table 7-1   Dual Polarized / Dual Slant Subscriber Antenna Electrical Specifications  Specification  Value  Frequency range 3.3 – 3.8 GHz  GAIN: H-Port & V-Port 22dBi  VSWR, max. 1.7 :  1  Polarization Dual Pole Linear, Vertical & Horizontal  Dual Slant (optional) ± 45°  3 dB Beam-Width, H-Plane, typ. 12°  3 dB Beam-Width, E-Plane, typ. 12°  Cross Polarization, max ETSI TS3  Front to Back Ratio, max. ETSI TS3  Port to Port Isolation, typ. -35 dB  Input power, max 10 Watt  Input Impedance 50 Ohm  Lightning Protection DC Grounded   Table 7-2   Dual Polarized / Dual Slant Subscriber Antenna Mechanical Specifications  Specification  Value  Dimensions (HxWxD) 370 x 370 x 40 mm (14.5" x14.5" x1.6") Weight 2.1 kg Connector 2x SMA, Female or 2x N-Type, Female  Back Plane Aluminum;  protected through chemical passivation  Radome Plastic UV Protected  Mount MNT-22   Table 7-3   Dual Polarized / Dual Slant Subscriber Antenna Environmental Specifications  Specification  Value  Operating Temperature Range - 55°C to + 65°C  Vibration According to IEC 60721-3-4  Wind Load 200 km/h (survival)  Flammability UL94  Continued
7-24 PMP320HDW2v1 Preliminary JUL 2010     Dual Polarization/Dual Slant Subscriber Antenna Chapter 7: Connectorized CSM Antenna Installation Instructions      Table 7-3   Dual Polarized / Dual Slant Subscriber Antenna Environmental Specifications (Continued) Specification  Value  Water Proofing IP-67  Humidity ETS 300 019-1-4, EN 302 085 (annex A.1.1  Salt Fog According to IEC 68-2-11  Ice and Snow 25mm radial (survival)  Service Life >10 years  The Standard Compliance of the Dual Polarized / Dual Slant Subscriber Antenna is ETSI TS3.   Parts List   Table 7-4   Dual Polarized / Dual Slant Subscriber Antenna Parts List  Quantity Description  1 Pole 1 inch to 4 inches (not supplied)  1 MNT-22–1  1 MNT-22–2  1 MNT-22–4  1 MNT-22–3  4 5/16 Helical spring lock washers  4 5/16 plain washer  2 5/16–18 x 1.25 inch Hex cap screws  2 5/16–18 x 5 inch hex cap screws  4 1/4 plain washer  4 1/4 helical spring lock washer  4 1/4–20 hex nut  2 5/16–18 hex nut
PMP320HDW2v1 7-25 Preliminary JUL 2010     PMP 320 Hardware Installation Dual Polarization/Dual Slant Subscriber Antenna      Figure 7-2   Mounting Bracket Parts Identification    G1_antassemblyparts.eps    Tools   The following tools are needed for the antenna mounting bracket assembly: • Torque driver – 30 in-lbs   Antenna Mounting Instructions  Use the following procedure to mount the Dual Polarized / Dual Slant Subscriber Antenna.   Figure 7-3   Dual Polarized / Dual Slant Subscriber Antenna Rear View for Mounting Assembly    G1_antassemblyrearview.eps
7-26 PMP320HDW2v1 Preliminary JUL 2010 Omni Directional Base Station Antenna Chapter 7: Connectorized CSM Antenna Installation Instructions           Procedure 7-1   Mounting the Dual Polarized / Dual Slant Subscriber Antenna to a pole   1 Place part number MNT-22–1 (antenna mounting plate) on the antenna and align with the screw holes. 2 Connect part number MNT-22–1 (middle mounting bracket) to the antenna mounting plate with four 1/4 inch spring washers, four 1/4 inch flat washers, and four 1/4–20 hex nuts.  Tighten the hex nuts with a torque driver to 30 in-lbs. 3 Attach part number MNT-22–2 to the antenna mounting plate assembly using a 5/16 inch helical spring lock washer, a 5/16 inch plain washer, a 5/16–18 x 1.25 inch hex cap screw, and a 5/16–18 hex nut.  Leave the assembly loosely tightened.  Do not torque the nuts at this step. 4 Attach part number MNT-22-3 (bottom pole mounting bracket) to the assembly from step 3.  Use a 5/16 inch helical spring lock washer, a 5/16 inch plain washer, a 5/16–18 x 1.25 inch hex cap screw, and a 5/16–18 hex nut. Leave the assembly loosely tightened.  Do not torque the nuts at this step. 5 Locate the area of the pole to mount the antenna, and place the bottom pole mounting bracket with the rest of the assembly on the pole. 6 Attach the top pole bracket part number MNT-22–4 to the bottom pole mounting bracket and assembly using two 5/16 helical spring lock washers, two plain washers, and two 5/16–18 x 5 inch hex cap screws. 7 Adjust the antenna ensuring that the antenna is set at a diagonal position. 8 Tighten all nuts at a torque of 30 in-lbs. 9 Connect the antenna to the connectorized CSM using the instructions in the Connectorized CSM Installation chapter.    Omni Directional Base Station Antenna   The Omni Directional Base Station Antenna features dual slant when it is mounted diagonally.  It also offers:  • stable performance with 9.5 dBi of gain  • compact size allowing easy blending in any environment  • UV protected radome suitable for harsh environments
PMP320HDW2v1 7-27 Preliminary JUL 2010 PMP 320 Hardware Installation Omni Directional Base Station Antenna          Figure 7-4   Omni Directional Base Station Antenna Identification                  G1_omnipolemntview.eps    Specifications   Table 7-5   Omni Directional Base Station Antenna Electrical Specification  Specification  Value  Frequency range 3.3- 3.8 GHz  GAIN, typ.  9.5 dBi@3.4-3.8  9 dBi@3.3-3.4  VSWR, max. 2 :  1  Polarization Linear, Vertical  3 dB Beam-Width, H-Plane, typ. Omni Directional  3 dB Beam-Width, E-Plane, typ. 10°  Input power, max 50 Watt  Input Impedance 50 Ohm   Table 7-6   Omni Directional Base Station Antenna Mechanical Specification  Specification  Value  Dimensions (HxDia.) 470 x 66 mm (18.5” x 2.  5”) Weight 350 gr. Connector N-Type, Female  Radome UV Protected , Plastic  Mount 2.5” PM (End) Attachment
7-28 PMP320HDW2v1 Preliminary JUL 2010 Omni Directional Base Station Antenna Chapter 7: Connectorized CSM Antenna Installation Instructions          Table 7-7   Omni Directional Base Station Antenna Environmental Specification  Specification  Value  Operating Temperature Range - 40°C to + 65°C  Vibration According to IEC 60721-3-4  Wind Load 200 km/h (survival)  Flammability UL94  Water Proofing IP-65  Humidity ETS 300 019-1-4, EN 302 085 (annex A.1.1)  Salt Fog According to IEC 68-2-11  Ice and Snow 25mm radial (survival)  Service Life >10 years   Parts List   Table 7-8   Omni Directional Base Station Antenna Pole Mounting Parts List  Quantity Description  2 U-brackets  4 Plain washers  4 Helical spring lock washers  4 Hex nuts    Figure 7-5   Omni Directional Base Station Antenna Parts Identification      G1_omnipolemntpartsid.eps    Tools   Hex wrench
PMP 320 Hardware Installation Omni Directional Base Station Antenna PMP320HDW2v1 7-29 JUL 2010 Preliminary     1 Locate the area of the pole where the Omni Directional Base Station Antenna will be mounted to the pole. 2 Slide the U-bracket around the pole. 3 Align the Omni Directional Base Station antenna bracket and pass the U-bracket through the bracket of the antenna. 4 Slide the plain washers on the U-bracket. 5 Slide the helical locking washers on the U-bracket 6 Use the nuts to securely fasten the antenna bracket to the U-bracket 7 Repeat step 2 through step step 6 for the second bracket.  Repeat these steps for the second antenna. 8 Connect the antenna to the connectorized CSM using the instructions in the      Antenna Mounting Instructions  Use the following procedure to mount the Omni Directional Base Station Antenna to a pole. Note that two Omni Directional Base Station Antennas are needed to support the Connectorized PMP 320 CSM.   Figure 7-6   Omni Directional Base Station Antenna Bracket Identification      G1_omnipolemntbracketconn.eps    Procedure 7-2   Procedure to mount an Omni Directional Base Station Antenna to a pole                    Connectorized CSM Installation chapter.
Omni Directional Base Station Antenna Chapter 7: Connectorized CSM Antenna Installation Instructions 7-30 PMP320HDW2v1 Preliminary JUL 2010
PMP320HDW2v1 7-31 JUL 2010 Preliminary     Chapter 8       Regulatory, Legal, and Safety Notices ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■  ■  ■  ■  ■
7-32 PMP320HDW2v1 Preliminary JUL 2010     IMPORTANT NOTE ON MODIFICATIONS Chapter 8: Regulatory, Legal, and Safety Notices  IMPORTANT NOTE ON MODIFICATIONS  ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■             ■             ■             ■             ■             ■  ■ Intentional or unintentional changes or modifications to the equipment must not be made unless under the express consent of the party responsible for compliance. Any such modifications could void the user’s authority to operate the equipment and will void the manufacturer’s warranty.   Federal Communication Commission Interference Statement  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.    These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.    However, there is no guarantee that interference will not occur in a particular installation.  If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:  -  Reorient or relocate the receiving antenna. -  Increase the separation between the equipment and receiver. -  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -  Consult the dealer or an experienced radio/TV technician for help.  FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.  This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  IMPORTANT NOTE: FCC Radiation Exposure Statement: 3630SMC complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator & your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. The availability of some specific channels and/or operational frequency bands are country dependent and are firmware programmed at the factory to match the intended destination. The firmware setting is not accessible by the end user.  Industry Canada statement: This device complies with RSS-192 of the Industry Canada Rules. Operation is subject to the following two conditions:  (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  IMPORTANT NOTE: Radiation Exposure Statement: This equipment complies with Canada radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 81 cm between the radiator & your body.  This device has been designed to operate with an antenna having a maximum gain of 22 dBi. Antenna having a higher gain is strictly prohibited per regulations of Industry Canada. The required antenna impedance is 50 ohms.
PMP320HDW2v1 8-33 Preliminary JUL 2010     PMP 320 Hardware Installation NATIONAL AND REGIONAL REGULATORY NOTICES     NATIONAL AND REGIONAL REGULATORY NOTICES  ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■              ■               ■             ■             ■             ■              ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■  ■ U.S. Federal Communication Commission (FCC) Notification   This device complies with Part 15 of the US FCC Rules and Regulations.  Operation is subject to the following two conditions: 1. This device may not cause harmful interference and  2. This device must accept any interference received, including interference that may cause undesired operation.  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the US FCC Rules.  These limits are designed to provide reasonable protection against harmful interference in a residential installation.  This equipment generates, uses, and can radiate radio-frequency energy and, if not installed and used in accordance with these instructions, may cause harmful interference to radio communications.  If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment on and off, the user is encouraged to correct the interference by one or more of the following measures: • Increase the separation between the affected equipment and the unit;  • Connect the affected equipment to a power outlet on a different circuit from that which the receiver is connected to;  • Consult the dealer and/or experienced radio/TV technician for help.   Table 8-1   FCC IDs and the specific configurations  FCC ID Operating Frequency Model Number Antenna Gain Channel Size Maximum Transmitter Output Power Maximum allowed EIRP  ABZ89FT7632 3.650  to 3.675 GHz      ABZ89FT7633 3.650 GHz to 3.675 GHz  3630APC 16.5 dBi       3630SM 14.5 dBi  10 MHz 22.91 dBm NA  7 MHz 21.35 dBm NA  5 MHz 19.81 dBm NA  3.5 MHz 18.33 dBm NA  10 MHz 10 MHz 10 W (40 dBm    Continued 7 MHz 24 dBm 7 W (38.5 dBm)5 MHz 22.5 dBm 5 W (37 dBm) 3.5 MHz 20.9 dBm 3.5  W  (35.4 dBm)
8-34 PMP320HDW2v1 Preliminary JUL 2010     10MHz 26.5 367MHz 25 34.55MHz 24 33.53.5MHz 23 32.510MHz 14 367MHz 13 355MHz 12 343.5MHz 11.5 33.5Industry Canada Notification Chapter 8: Regulatory, Legal, and Safety Notices   Table 8-1   FCC IDs and the specific configurations (Continued) Maximum FCC ID Operating Frequency Model Number Antenna Gain Channel Size Transmitter Output Power Maximum allowed EIRP  ABZ89FT7636 3.650 GHz to 3.675 GHz  3630SMC 9.5      ABZ89FT7636 3.650 GHz to    3630SMC     22 3.675 GHz        Industry Canada Notification This device is approved for use in Canada in the licensed frequencies from 3.450 GHz to 3.700 GHz.  It is undergoing Industry Canada approval for use in the 3.65 GHz band, and may not be used in that band until Industry Canada approval is granted.  Operation is subject to the following two conditions: • This device may not cause harmful interference and  • This device must accept any interference received, including interference that may cause undesired operation.  This equipment has been tested and found to comply with the limits for a Class B digital device. These limits are designed to provide reasonable protection against harmful interference in a residential installation.  This equipment generates, uses, and can radiate radio-frequency energy and if not installed and used in accordance with these instructions, may cause harmful interference to radio communications.  If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment on and off, the user is encouraged to correct the interference by one or more of the following measures:  • Increase the separation between the affected equipment and the unit;  • Connect the affected equipment to a power outlet on a different circuit from that which the receiver is connected to;  • Consult the dealer and/or experienced radio/TV technician for help.  To reduce potential radio interference to other users, the antenna type and its gain should be chosen so its Equivalent Isotropic Radiated Power (EIRP) is not more than that permitted for successful communication.  For 3630APC (3600~3650 MHz)   This device has been designed to operate with an antenna having a maximum gain of 17 dBi. Antenna having a higher gain is strictly prohibited per regulations of Industry Canada. The required antenna impedance is 50 ohms.    For 3630APC (3650~3700MHz)   This device has been designed to operate with an antenna having a maximum gain of 16.5 dBi. Antenna having a higher gain is strictly prohibited per regulations of Industry Canada. The required antenna impedance is 50 ohms.    For 3530SMC/3630SMC This device has been designed to operate with an antenna having a maximum gain of 22 dBi. Antenna having a higher gain is strictly prohibited per regulations of Industry Canada. The required antenna impedance is 50 ohms.   PMP 320 Hardware Installation European Union Notification
PMP320HDW2v1 8-35 Preliminary JUL 2010       Table 8-2   Industry Canada Certification Numbers and the specific configuration    IC ID  Operating Frequency Model number  Antenna Gain  Channel Size Maximum Allowed EIRP Maximum Transmitter Output power 109 W-3530APC  3450~3600MHz 3530 APC 16.5 dBi connectorizedany NA  27dBm (500mW) 109W-3630APC 3600~3650MHz  3636APC  17 dBi any  NA  27dBm (500mW) 109W-3630APC 3650~3700MHz  3636APC  16.5 dBi any  NA  25dBm (316mW) 109W-3530SM 3450~3600MHz  3530SM 14.5 dBi NA  NA  27dBm (500mW) 109W-3630SM 3600~3700MHz  3630SM 14.5 dBi NA  NA  27dBm (500mW) 109W-3530SMC 3450~3600MHz  3530SMC  22 dBi  NA  NA  27 dBm (500mW) 109W-3630SMC 3600~3700MHz  3639SMC  NA  NA  NA  TBD  European Union Notification   The relevant Declaration of Conformity can be found at  http://motorola.wirelessbroadbandsupport.com/doc.php   Equipment Disposal          Please do not dispose of Electronic and Electric Equipment or Electronic and Electric Accessories with your household waste.  In some countries or regions, collection systems have been set up to handle waste of electrical and electronic equipment.  In European Union countries, please contact your local equipment supplier representative or service center for information about the waste collection system in your country.   EU Declaration of Conformity for RoHS Compliance   Motorola hereby, declares that these Motorola products are in compliance with the essential requirements and other relevant provisions of Directive 2002/95/EC, Restriction of the use of certain Hazardous Substances (RoHS) in electrical and electronic equipment.
8-36 PMP320HDW2v1 Preliminary JUL 2010     ProductsLabeling and Disclosure Table for China Chapter 8: Regulatory, Legal, and Safety Notices      The relevant Declaration of Conformity can be found at http://motorola.wirelessbroadband- . support.com/doc.php   Labeling and Disclosure Table for China   The People’s Republic of China requires that Motorola’s products comply with ChinaManagement Methods (CMM) environmental regulations.  (China Management Methods refers to the regulation Management Methods for Controlling Pollution by Electronic Information .) Two items are used to demonstrate compliance - the label, and the disclosure table . Table 6 3 Disclosure table  The label is placed in a customer visible position on the product. • Logo 1 means that the product contains no substances in excess of the maximum concentration value for materials identified in the China Management Methods regulation.  • Logo 2 means that the product may contain substances in excess of the maximum concentration value for materials identified in the China Management Methods regulation, and has an Environmental Friendly Use Period (EFUP) in years, fifty years in the example shown.  Logo 1                                     Logo 2      The Environmental Friendly Use Period (EFUP) is the period (in years) during which the Toxic and Hazardous Substances (T&HS) contained in the Electronic Information Product (EIP) will not leak or mutate causing environmental pollution or bodily injury from the use of the EIP. The EFUP indicated by the Logo 2 label applies to a product and all its parts.  Certain field-replaceable parts, such as battery modules, can have a different EFUP and are marked separately.  The Disclosure table is intended to communicate compliance with only China requirements; it is not intended to communicate compliance with EU RoHS or any other environmental requirements.   Figure 8-1   Disclosure Table
PMP320HDW2v1 8-37 Preliminary JUL 2010     ,FieldsPMP 320 Hardware Installation RF EXPOSURE SEPARATION DISTANCES      RF EXPOSURE SEPARATION DISTANCES  ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■              ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■  ■  ■   To protect from overexposure to RF energy, an AP must be installed to provide a separation distance of at least 50 cm ( ~20 in) from all persons In addition, do not collocate within 20 cm (4 in) of any other antenna or transmitter.  To protect from overexposure to RF energy, an SM must be installed to provide a separation distance of at least 50 cm ( ~20 in) from all persons and must not be collocated or operating with any other antenna or transmitter.  The following section and table provide details and discussion on the separate distance calculations.  To protect from overexposure to EU RF energy, An 3530SMC must be installed to provide a separation distance of at least 82 cm from all persons and must be not collocated or operating with any other antenna or transmitter.  To protect from overexposure to EU RF energy, An 3630SMC must be installed to provide a separation distance of at least 120 cm from all persons and must be not collocated or operating with any other antenna or transmitter.    Details of Exposure Separation Distances Calculations and Power Compliance Margins   Limits and guidelines for RF exposure come from: • US FCC limits for the general population.  See the FCC web site at http://www.fcc.gov the policies, guidelines, and requirements in Part 1 of Title 47 of the Code of Federal  and Regulations, as well as the guidelines and suggestions for evaluating compliance in FCC OET Bulletin 65.  • Health Canada limits for the general population.  See the Health Canada web site at http://www.hc-sc.gc.ca/rpb and Safety Code 6.  • ICNIRP (International Commission on Non-Ionizing Radiation Protection) guidelines for the general public.  See the ICNIRP web site at http://www.icnirp.de/ and Guidelines for Limiting Exposure to Time-Varying Electric, Magnetic, and Electromagnetic .  The applicable power density exposure limits from the documents referenced above is 10 W/m2. Peak power density in the far field of a radio frequency point source is calculated as:   Figure 8-2   Peak power density calculation
8-38 PMP320HDW2v1 Preliminary JUL 2010        Table 8-3 shows calculated minimum separation distances d, recommended distances and resulting power compliance margins for each frequency band and antenna combination. Details of Exposure Separation Distances Calculations and Power Compliance Margins Chapter 8: Regulatory, Legal, and Safety Notices          Table 8-3   Calculated exposure distances and power compliance margins  P( dBm )  P( W )  G  S  Distance (cm , Calculated ) 3630APC 25.1 0.324  16.5 10 33.92 3630SM 27.06 0.508  14.5 10 33.76  These are conservative distances: • They are along the beam direction (the direction of greatest energy).  Exposure to the sides and back of the module is significantly less.  • In the case of collocated APs, they assume all APs are oriented in the same direction, which is a worst-case calculation.  • They meet or exceed sustained exposure limits for the general population (not just short-term occupational exposure limits).  • The calculated compliance distance d is overestimated because the far-field equation models the antenna(s) as a point source and neglects the physical dimension of the antenna(s).   Table 8-4   Exposure separation distances  Module Type Separation Distance from Persons  Radio Module with integrated antenna    At least 20 cm (approximately 8 inches)  Module with Reflector Dish At least 1.5 m (approximately 60 inches or 5 feet)  Module with LENS At least 0.5 m (approximately 20 inches)  Antenna of connectorized 5.7 GHz AP At least 30 cm (approximately 12 inches)  Antenna  of  connectorized  or integrated 900 MHz module  At least 60 cm (approximately 24 inches)  Indoor 900 MHz SM At least 10 cm (approximately 4
PMP320HDW2v1 8-39 Preliminary JUL 2010     inches)  PMP 320 AP At least 50 cm (approximately 20 inches)
8-40 PMP320HDW2v1 Preliminary JUL 2010     PMP 320 Hardware Installation Software License Terms and Conditions     Software License Terms and Conditions  ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■  ■  ■   ONLY OPEN THE PACKAGE, OR USE THE SOFTWARE AND RELATED PRODUCT IF YOU ACCEPT THE TERMS OF THIS LICENSE. BY BREAKING THE SEAL ON THIS DISK KIT / CDROM, OR IF YOU USE THE SOFTWARE OR RELATED PRODUCT, YOU ACCEPT THE TERMS OF THIS LICENSE AGREEMENT. IF YOU DO NOT AGREE TO THESE TERMS, DO NOT USE THE SOFTWARE OR RELATED PRODUCT; INSTEAD, RETURN THE SOFTWARE TO PLACE OF PURCHASE FOR A FULL REFUND. THE FOLLOWING AGREEMENT IS A LEGAL AGREEMENT BETWEEN YOU (EITHER AN INDIVIDUAL OR ENTITY), AND MOTOROLA, INC. (FOR ITSELF AND ITS LICENSORS). THE RIGHT TO USE THIS PRODUCT IS LICENSED ONLY ON THE CONDITION THAT YOU AGREE TO THE FOLLOWING TERMS.  Now, therefore, in consideration of the promises and mutual obligations contained herein, and for other good and valuable consideration, the receipt and sufficiency of which are hereby mutually acknowledged, you and Motorola agree as follows:  Grant of License.  Subject to the following terms and conditions, Motorola, Inc., grants to you a personal, revocable, non-assignable, non-transferable, non-exclusive and limited license to use on a single piece of equipment only one copy of the software contained on this disk (which may have been pre-loaded on the equipment)(Software).  You may make two copies of the Software, but only for backup, archival, or disaster recovery purposes.  On any copy you make of the Software, you must reproduce and include the copyright and other proprietary rights notice contained on the copy we have furnished you of the Software.  Ownership.  Motorola (or its supplier) retains all title, ownership and intellectual property rights to the Software and any copies, including translations, compilations, derivative works (including images) partial copies and portions of updated works.  The Software is Motorola’s (or its supplier's) confidential proprietary information.  This Software License Agreement does not convey to you any interest in or to the Software, but only a limited right of use.  You agree not to disclose it or make it available to anyone without Motorola’s written authorization.  You will exercise no less than reasonable care to protect the Software from unauthorized disclosure.  You agree not to disassemble, decompile or reverse engineer, or create derivative works of the Software, except and only to the extent that such activity is expressly permitted by applicable law.  Termination. This License is effective until terminated. This License will terminate immediately without notice from Motorola or judicial resolution if you fail to comply with any provision of this License.  Upon such termination you must destroy the Software, all accompanying written materials and all copies thereof, and the sections entitled Limited Warranty, Limitation of Remedies and Damages, and General will survive any termination.  Limited Warranty.  Motorola warrants for a period of ninety (90) days from Motorola’s or its customer’s shipment of the Software to you that (i) the disk(s) on which the Software is recorded will be free from defects in materials and workmanship under normal use and (ii) the Software, under normal use, will perform substantially in accordance with Motorola’s published specifications for that release level of the Software.  The written materials are provided "AS IS" and without warranty of any kind.  Motorola's entire liability and your sole and exclusive remedy for any breach of the foregoing limited warranty will be, at Motorola's option, replacement of the disk(s), provision of downloadable patch or replacement code, or refund of the unused portion of your bargained for contractual benefit up to the amount paid for this Software License.
PMP320HDW2v1 8-41 Preliminary JUL 2010     Software License Terms and Conditions Chapter 8: Regulatory, Legal, and Safety Notices      THIS LIMITED WARRANTY IS THE ONLY WARRANTY PROVIDED BY MOTOROLA, AND MOTOROLA AND ITS LICENSORS EXPRESSLY DISCLAIM ALL OTHER WARRANTIES, EITHER EXPRESS OF IMPLIED, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. MOTOROLA DOES NOT WARRANT THAT THE OPERATION OF THE SOFTWARE WILL BE UNINTERRUPTED OR ERRORFREE, OR THAT DEFECTS IN THE SOFTWARE WILL BE CORRECTED. NO ORAL OR WRITTEN REPRESENTATIONS MADE BY MOTOROLA OR AN AGENT THEREOF SHALL CREATE A WARRANTY OR IN ANY WAY INCREASE THE SCOPE OF THIS WARRANTY. MOTOROLA DOES NOT WARRANT ANY SOFTWARE THAT HAS BEEN OPERATED IN EXCESS OF SPECIFICATIONS, DAMAGED, MISUSED, NEGLECTED, OR IMPROPERLY INSTALLED. BECAUSE SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF IMPLIED WARRANTIES, THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU.  Limitation of Remedies and Damages.  Regardless of whether any remedy set forth herein fails of its essential purpose, IN NO EVENT SHALL MOTOROLA OR ANY OF THE LICENSORS, DIRECTORS, OFFICERS, EMPLOYEES OR AFFILIATES OF THE FOREGOING BE LIABLE TO YOU FOR ANY CONSEQUENTIAL, INCIDENTAL, INDIRECT, SPECIAL OR SIMILAR DAMAGES WHATSOEVER (including, without limitation, damages for loss of business profits, business interruption, loss of business information and the like), whether foreseeable or unforeseeable, arising out of the use or inability to use the Software or accompanying written materials, regardless of the basis of the claim and even if Motorola or a Motorola representative has been advised of the possibility of such damage.  Motorola's liability to you for direct damages for any cause whatsoever, regardless of the basis of the form of the action, will be limited to the price paid for the Software that caused the damages.  THIS LIMITATION WILL NOT APPLY IN CASE OF PERSONAL INJURY ONLY WHERE AND TO THE EXTENT THAT APPLICABLE LAW REQUIRES SUCH LIABILITY. BECAUSE SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, THE ABOVE LIMITATION MAY NOT APPLY TO YOU.  Maintenance and Support.  Motorola shall not be responsible for maintenance or support of the software.  By accepting the license granted under this agreement, you agree that Motorola will be under no obligation to provide any support, maintenance or service in connection with the Software or any application developed by you.  Any maintenance and support of the Related Product will be provided under the terms of the agreement for the Related Product.  Transfer.  In the case of software designed to operate on Motorola equipment, you may not transfer the Software to another party except:  (1) if you are an end-user, when you are transferring the Software together with the Motorola equipment on which it operates; or 2) if you are a Motorola licensed distributor, when you are transferring the Software either together with such Motorola equipment or are transferring the Software as a licensed duly paid for upgrade, update, patch, new release, enhancement or replacement of a prior version of the Software.  If you are a Motorola licensed distributor, when you are transferring the Software as permitted herein, you agree to transfer the Software with a license agreement having terms and conditions no less restrictive than those contained herein.  You may transfer all other Software, not otherwise having an agreed restriction on transfer, to another party.  However, all such transfers of Software are strictly subject to the conditions precedent that the other party agrees to accept the terms and conditions of this License, and you destroy any copy of the Software you do not transfer to that party.  You may not sublicense or otherwise transfer, rent or lease the Software without our written consent.  You may not transfer the Software in violation of any laws, regulations, export controls or economic sanctions imposed by the US Government.  Right to Audit.  Motorola shall have the right to audit annually, upon reasonable advance notice and during normal business hours, your records and accounts to determine compliance with the terms of this Agreement.  Export Controls.  You specifically acknowledge that the software may be subject to United States and other country export control laws.  You shall comply strictly with all requirements of all applicable export control laws and regulations with respect to all such software and materials.
8-42 PMP320HDW2v1 Preliminary JUL 2010     PMP 320 Hardware Installation Software License Terms and Conditions      US Government Users.  If you are a US Government user, then the Software is provided with "RESTRICTED RIGHTS" as set forth in subparagraphs (c)(1) and (2) of the Commercial Computer Software-Restricted Rights clause at FAR 52 227-19 or subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013, as applicable.  Disputes.  You and Motorola hereby agree that any dispute, controversy or claim, except for any dispute, controversy or claim involving intellectual property, prior to initiation of any formal legal process, will be submitted for non-binding mediation, prior to initiation of any formal legal process.  Cost of mediation will be shared equally.  Nothing in this Section will prevent either party from resorting to judicial proceedings, if (i) good faith efforts to resolve the dispute under these procedures have been unsuccessful, (ii) the dispute, claim or controversy involves intellectual property, or (iii) interim relief from a court is necessary to prevent serious and irreparable injury to that party or to others.  General.  Illinois law governs this license.  The terms of this license are supplemental to any written agreement executed by both parties regarding this subject and the Software Motorola is to license you under it, and supersedes all previous oral or written communications between us regarding the subject except for such executed agreement.  It may not be modified or waived except in writing and signed by an officer or other authorized representative of each party.  If any provision is held invalid, all other provisions shall remain valid, unless such invalidity would frustrate the purpose of our agreement.  The failure of either party to enforce any rights granted hereunder or to take action against the other party in the event of any breach hereunder shall not be deemed a waiver by that party as to subsequent enforcement of rights or subsequent action in the event of future breaches.
PMP320HDW2v1 8-43 Preliminary JUL 2010     Hardware Warranty in US Chapter 8: Regulatory, Legal, and Safety Notices     Hardware Warranty in US  ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■  ■  ■   Motorola US offers a warranty covering a period of 1 year from the date of purchase by the customer.  If a product is found defective during the warranty period, Motorola will repair or replace the product with the same or a similar model, which may be a reconditioned unit, without charge for parts or labor.
8-44 PMP320HDW2v1 Preliminary JUL 2010     PMP 320 Hardware Installation LIMIT OF LIABILITY     LIMIT OF LIABILITY  ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■              ■               ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■             ■              ■             ■             ■              ■             ■             ■             ■             ■             ■              ■  ■  ■   IN NO EVENT SHALL MOTOROLA BE LIABLE TO YOU OR ANY OTHER PARTY FOR ANY DIRECT, INDIRECT, GENERAL, SPECIAL, INCIDENTAL, CONSEQUENTIAL, EXEMPLARY OR OTHER DAMAGE ARISING OUT OF THE USE OR INABILITY TO USE THE PRODUCT (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR ANY OTHER PECUNIARY LOSS, OR FROM ANY BREACH OF WARRANTY, EVEN IF MOTOROLA HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. (Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion or limitation may not apply to you.)  IN NO CASE SHALL MOTOROLA’S LIABILITY EXCEED THE AMOUNT YOU PAID FOR THE PRODUCT.

Navigation menu