Mueller Systems MINODE-CIH MiNODE-CI Modular TX User Manual Radio System Theory of Operations

Mueller Systems, LLC MiNODE-CI Modular TX Radio System Theory of Operations

Users Manual

Download: Mueller Systems MINODE-CIH MiNODE-CI Modular TX User Manual Radio System Theory of Operations
Mirror Download [FCC.gov]Mueller Systems MINODE-CIH MiNODE-CI Modular TX User Manual Radio System Theory of Operations
Document ID1491837
Application IDZmV/Kx618ebmCWH87ncaxg==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize27.31kB (341379 bits)
Date Submitted2011-06-29 00:00:00
Date Available2011-06-29 00:00:00
Creation Date2011-06-21 07:55:32
Producing SoftwareMicrosoft® Office Word 2007
Document Lastmod2011-06-21 07:55:32
Document TitleRadio System Theory of Operations
Document CreatorMicrosoft® Office Word 2007
Document Author: William Shoesmith

Mi.Node – CI
Installation Manual
880-0042-001
Document Rev
This Mueller Systems proprietary and confidential document shall not be reproduced or
retransmitted in any way without expressed written consent from Mueller Systems
MI.NODE – C&I Installation Manual
Document Information
Title:
Version:
MI.NODE - CI (Mi.Node CI) Installation Manual
2.0
Created:
9/22/2009
Last Modified On:
6/1/2011
Author:
Tom Cullinan
Technical Lead:
Contributors:
Dave Splitz
Revision History
Version
Date
Author
1.0
9/22/2009
TC
Comments
Initial draft, submitted for review
2.0
6/1/2011
DS
Revised label (CIH) per ECN11013
Reviewers
Reviewed By
Rev 2.0
Title
Date Reviewed
Mueller Systems – Confidential
Page ii
MI.NODE – C&I Installation Manual
Table of Contents
1.
Introduction .............................................................................................. 1
2.
Product Labeling ........................................................................................ 1
2.1 PRODUCT IDENTIFICATION ................................................................................. 1
2.2 FCC IDENTIFICATION ....................................................................................... 2
Table of Figures
FIGURE 1. PRODUCT IDENTIFICATION LABEL ....................................................................... 2
FIGURE 2. MI.NODE-CI FCC ID TEXT ............................................................................ 2
Rev 2.0
Mueller Systems – Confidential
Page iii
MI.NODE – C&I Installation Manual
FCC Information:
Changes or modifications not expressly approved by the Mueller
Systems could void the user's authority to operate the equipment.
IMPORTANT NOTE: To comply with FCC RF exposure compliance
requirements, the antenna used for this transmitter must be installed
to provide a separation distance of at least 20 cm from all persons and
must not be co-located or operating in conjunction with any other
antenna or transmitter.
“NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference in
a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
Rev 2.0
Mueller Systems – Confidential
Page iv
MI.NODE – C&I Installation Manual
1. Introduction
The Mueller Systems MiNODE-CI is intended for indoor & outdoor use as an unattended
automatic metering Infrastructure (AMI) & control device. The SMART METER-CI product
consists of a Mueller Systems AMI MiNODE-CI module fully integrated into a Landis+Gyr C&I
(Commercial & Industrial) solid state electric meter.
The Smart Meter-CI is fully self-contained with no user accessible controls.
The MiNODE-CI interrogates the ANSI C.12 register set in C&I solid-state electric
meters from Landis + Gyr. It’s main function is to obtain energy consumption, negative
consumption, and voltage readings for billing, distribution monitoring, fraud detection,
and conservation purposes.
Meter reading interval is remotely settable. Information retrieved from the meters
registers are temporarily stored within the solid-state memory. On a specified interval, the
MiNODE-CI will automatically transmit this information to the Mueller Systems AMI server
via. other meters or MiGATE using the Radio Frequency (RF) network.
The Mueller Systems AMI server analyzes and archives the readings.
The MiNODE-CI uses SuperCapacitors to support transmission of power failure
messages and to maintain the time of day clock. The Smart Meter does not use any
internal batteries eliminating need for field service.
The contents of this installation manual are intended for technically qualified personnel of
energy distribution utilities who have been trained and are technically qualified in basic
electrical principles, including safety procedures for installation of energy meters.
The installer should refer to the latest edition of the Landis+Gyr “FOCUS kWh Solid-State
Meter Technical Manual” for physical installation, wiring, and safety precautions.
2. Supported Products
• MiNODE CI
The MiDODE-CI supports the following electric meter forms
Form
Voltage
Current
3. Maintenance
There are no user serviceable items within a SmartMeter CI. No cleaning is required.
2. Product Labeling
2.1 Product Identification
This label is affixed to the face of the SmartMeter CI unit. This allows the installer to easily
scan the label with the Mi.Tech hand-held during the installation process. This label includes
Rev 2.0
Mueller Systems – Confidential
Page 1
MI.NODE – C&I Installation Manual
the Date of Manufacture, the Hardware Version and the MI.NODE–CI /Serial Number (Node
ID) that is used to uniquely address the device and Assembled in Mexico.
Figure 1. Product Identification Label
2.2 FCC Identification
This label is affixed to the side of the SmartMeter CI enclosure and indicates the FCC ID
number of the product.
This product contains Module FCC ID: SM6-MINODE-CIH
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions; (1) this
device may not cause harmful interference, and (2) this
device must accept any interference received, including
interference that may cause undesired operation.
Figure 2. MI.NODE-CI FCC ID text
Rev 2.0
Mueller Systems – Confidential
Page 2

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 6
Language                        : en-US
Tagged PDF                      : Yes
Title                           : Radio System Theory of Operations
Author                          : William Shoesmith
Subject                         : RF Operations
Creator                         : Microsoft® Office Word 2007
Create Date                     : 2011:06:21 07:55:32
Modify Date                     : 2011:06:21 07:55:32
Producer                        : Microsoft® Office Word 2007
EXIF Metadata provided by EXIF.tools
FCC ID Filing: SM6-MINODE-CIH

Navigation menu