Mueller Systems MINODE-LGSB LGSB-MINODE Radio User Manual Radio System Theory of Operations
Mueller Systems, LLC LGSB-MINODE Radio Radio System Theory of Operations
manual
Mueller Systems LGSB Installation Manual PN 880-0078-001 Rev A00 LGSB Install Manual Document Information Title: Version: LGSB Installation Manual A00 Created: 11/1/11 Last Modified On: 11/2/11 Author: Technical Lead: Contributors: Revision History Version Date Author Comments 0.1 11/1/11 ECP Initial draft, from 880-0023 A00 11/2/11 ECP Minor Edits Reviewers Reviewed By Page ii Title Mueller Technologies, LLC – Confidential Date Reviewed Rev A00 LGSB Install Manual Table of Contents 1. 2. 3. 4. 4.1 4.2 Introduction .............................................................................................. 1 Supported Products ................................................................................... 1 Maintenance .............................................................................................. 1 Product Labeling ........................................................................................ 1 PRODUCT IDENTIFICATION ................................................................................. 1 FCC IDENTIFICATION ....................................................................................... 2 Table of Figures FIGURE 1. PRODUCT IDENTIFICATION LABEL ....................................................................... 2 FIGURE 2 FCC LABEL LGSB .......................................................................................... 2 Rev A00 Mueller Technologies, LLC – Confidential Page iii LGSB Install Manual FCC Information Changes or modifications not expressly approved by Mueller Technologies, LLC could void the user's authority to operate the equipment. IMPORTANT NOTE: To comply with FCC RF exposure compliance requirements, the antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. “NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. Page iv Mueller Technologies, LLC – Confidential Rev A00 LGSB Install Manual 1. Introduction The Mueller Systems LGSB SmartMeter is intended for indoor & outdoor use as an unattended automatic metering Infrastructure (AMI) & control device. The LGSB SmartMeter product consists of a Landis+Gyr Focus solid state electric meter and Mueller Systems radio. The LGSB SmartMeter is fully self-contained with no user accessible controls. The SmartMeter interrogates the ANSI C.12 register set in Focus solid-state electric meters from Landis + Gyr. Its main function is to obtain energy consumption, negative consumption, and voltage readings for billing, distribution monitoring, fraud detection, and conservation purposes. Meter reading interval is remotely settable. Information retrieved from the meters registers is temporarily stored within the LGSB SmartMeter solid-state memory. On a specified interval, the LGSB SmartMeter will automatically transmit this information to the Mueller AMI server via other meters or a MiHUB using the Radio Frequency (RF) network. The Mueller AMI server analyzes and archives the readings. The LGSB SmartMeter uses SuperCapacitors to support transmission of power failure messages and to maintain the time of day clock. The SmartMeter does not use any internal batteries eliminating need for field service. The contents of this installation manual are intended for technically qualified personnel of energy distribution utilities who have been trained and are technically qualified in basic electrical principles, including safety procedures for installation of energy meters. The installer should refer to the latest edition of the Landis+Gyr “FOCUS kWh Solid-State Meter Technical Manual” for physical installation, wiring, and safety precautions. 2. Supported Products The LGSB SmartMeter product only supports the 2S Class 200 form. 3. Maintenance There are no user serviceable items within a SmartMeter. No cleaning is required. 4. Product Labeling 4.1 Product Identification This label is affixed to the face of the SmartMeter meter. Rev A00 Mueller Technologies, LLC – Confidential Page 1 LGSB Install Manual Figure 1. Product Identification Label 4.2 FCC Identification Figure 2 FCC Label LGSB Page 2 Mueller Technologies, LLC – Confidential Rev A00
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : William Shoesmith Create Date : 2011:11:02 08:59:20Z Modify Date : 2011:11:02 16:23:26-04:00 Subject : RF Operations Language : en-US Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Format : application/pdf Creator : William Shoesmith Description : RF Operations Title : Radio System Theory of Operations Creator Tool : Microsoft® Office Word 2007 Metadata Date : 2011:11:02 16:23:26-04:00 Producer : Microsoft® Office Word 2007 Document ID : uuid:675d93aa-6447-4c21-ae5e-b0fd31393e8d Instance ID : uuid:c01fd59a-11bd-42cd-b57d-5a01c6b5bc70 Page Count : 6EXIF Metadata provided by EXIF.tools