Mueller Systems MINODE-M Automatic Metering and Control Device User Manual

Mueller Systems, LLC Automatic Metering and Control Device

Contents

User Manual

Download: Mueller Systems MINODE-M Automatic Metering and Control Device User Manual
Mirror Download [FCC.gov]Mueller Systems MINODE-M Automatic Metering and Control Device User Manual
Document ID3077057
Application IDEWJm8dIKOcR5sQQPniehOA==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize40.39kB (504935 bits)
Date Submitted2016-07-26 00:00:00
Date Available2016-07-26 00:00:00
Creation Date2016-07-13 15:39:46
Producing SoftwareMicrosoft® Office Word 2007
Document Lastmod2016-07-13 15:39:46
Document TitleUser Manual
Document CreatorMicrosoft® Office Word 2007
Document Author: Dan McGoldrick

Mi.Node M
Installation Manual
Mi.Node M Installation Manual
Contents
1. Introduction ................................................................................................................................ 4
2. Construction ................................................................................................................................ 4
3. Installation .................................................................................................................................. 5
3.1 Pit Set Installation ............................................................................................. 5
3.2 Exterior Wall Mounting ....................................................................................... 5
3.3 Wiring .............................................................................................................. 6
3.4 Verification ....................................................................................................... 6
4. Maintenance ............................................................................................................................... 6
5. Product Labeling .......................................................................................................................... 6
5.1 Product and FCC/IC Identification ........................................................................ 6
5.2 IC Information .................................................................................................. 7
Table of Tables
TABLE 1. Mi.Node M METER INTERCONNECT ............................................................................ 6
Table of Figures
FIGURE 1. PRODUCT IDENTIFICATION LABEL............................................................................ 6
Mueller Systems – Proprietary
Page 2
Mi.Node M Installation Manual
FCC Information:
Changes or modifications not expressly approved by the Mueller Systems could
void the user's authority to operate the equipment.
IMPORTANT NOTE: To comply with FCC RF exposure compliance
requirements, the antenna used for this transmitter must be installed to
provide a separation distance of at least 20 cm from all persons and must not
be co-located or operating in conjunction with any other antenna or
transmitter.
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesired operation.
“NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following
measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
IC Information
Under Industry Canada regulations, this radio transmitter may only operate using an
antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry
Canada. To reduce potential radio interference to other users, the antenna type and its gain
should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more
than that necessary for successful communication.
Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut
fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour
l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage
radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son
gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas
l'intensité nécessaire à l'établissement d'une communication satisfaisante.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is
subject to the following two conditions: (1) this device may not cause interference, and (2)
this device must accept any interference, including interference that may cause undesired
operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils
radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1)
l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter
tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre
le fonctionnement.
Mueller Systems – Proprietary
Page 3
Mi.Node M Installation Manual
1. Introduction
The Mueller Systems Mi.Node M is intended for indoor and outdoor use as an
unattended Automatic Metering Infrastructure (AMI) and control device. The Mi.Node
M is fully self-contained and battery powered device with no user accessible controls.
The Mi.Node M for Residential Metering (“Mi.Node M”) is a
device that incorporates a microcontroller, 915MHz ISM band
transceiver (simplex operation), and battery (DC power supply)
for the purpose of logging and forwarding water meter readings
to the Mueller Systems servers. The readings are forwarded to
server via other Mi.Node M, Mi.Hub data collectors, or Smart
Meters at assigned times. The Mi.Node M will also autonomously
send messages to the server when various events or alert
conditions are detected, such as potential leak or theft of
service.
Meter reading interval is remotely settable. Information
retrieved from the meters registers are temporarily stored within the Mi.Node M’s solidstate memory. On a specified interval, the Mi.Node M will automatically transmit this
information to the Mueller Systems AMI server via other meters or MIHUBs using the
Radio Frequency (RF) network. The Mueller Systems AMI server analyzes and archives
the readings.
The contents of this installation manual are intended for technically qualified personnel
of water and energy distribution utilities who have been trained and are technically
qualified in local safety procedures for installation of the device.
2. Construction
The Mi.Node M product consists of a printed circuit board which is encapsulated to
provide complete protection against shock and water intrusion. The enclosure is made of UV
stable, high density thermoplastic and is completely waterproof. The UV stable,
thermoplastic housing design provides a compact, waterproof enclosure that is lightweight
and easy to handle and install. The Mi.Node M has integral mounting brackets for both
pit and wall installations. One D size lithium battery provides plenty of power for
reading the register and sending RF data.
In order to protect the AMI device electronics from moisture ingress the
design incorporates the use of thermoplastic injection molded housings, rubber
seals, a potting compound that completely incases the internal electronics
and a coated circuit board which combine to provide a formidable barrier of
protection against water intrusion.
Internal wire strain relief has been built into the housing to protect the wire
connections against damage. Please note that meters or registers should never
be carried while supported only by the Mi.Node M transmitter or wiring.
A monopole antenna is located in the upper housing to provide powerful RF
communication.
A single D cell long life Lithium battery is located in the lower housing which
provides power for register interrogation and data transmission for a calculated
battery life of up to 20 years.
Mueller Systems – Proprietary
Page 4
Mi.Node M Installation Manual
There are no customer serviceable parts inside the Mi.Node M housing. Batteries
are not replaceable.
The electronic design utilizes the latest RF microchip technology which
increases reliability when compared to older RF designs.
3. Installation
Mi.Node M modules support two mounting options, either mounting to a ½” PVC pipe
for pit set installations or affixed to the side of a building. Pit set installations
require no drilled holes through the lid and are mounted beneath the polymer meter
box lid for security and ease of installation on PVC pipe. Surface mounts are
easily accomplished with the integral mounting brackets and two screws (not
included).
3.1 Pit Set Installation
Please note that meters or registers should never be carried while supported only
by the AMR transmitter or wiring.
Tools Required: Length of ½” PVC pipe for pit depth, hammer
1. PVC pipe should be cut to the proper length and installed deep
enough in the floor of each meter box that subsequent flooding
will not allow the stake and Mi.Node M to change position. The
Mi.Node M includes a ½” female PVC pipe fitting for easy pit
installation.
2. For maximum radio performance, once installed, the top
of the transmitter should be located approximately ½” inch
below the pit lid in the center of the meter box to maximize RF
performance.
3. Once the PVC stake is installed, the Mi.Node M should be
pushed down onto the stake by hand until the interference fit
engages securely. Two solid stops are molded into the PVC
Installation Slot in order to prevent the wire from being
pinched when installed.
Never hammer Mi.Node M onto the stake since this may result in damage to
the electronic components inside the unit.
4. Always mount the Mi.Node M in a vertical orientation, with the antenna
compartment on top and the battery compartment on the bottom.
3.2 Exterior Wall Mounting
Tools required: 1 – 1 1/2 inch galvanized, or stainless wood or sheet
metal screws (2 per), Phillips screwdriver
1. The open ended wire from the device permits routing through
interior walls for external wall mounting when required or
direct mounting to exposed floor joists above grade level.
Mueller Systems – Proprietary
Page 5
Mi.Node M Installation Manual
2. Mi.Node M can be directly mounted to almost any flat surface
by using the holes shown and common screws in most
instances.
3. Vertical orientation of the device is required to maximize RF
performance.
3.3 Wiring
Tools Required: 3M-2Y connectors, splitting tube, and a 3M Crimping Tool
Mi.Node M
Translator Register
Badger ADE Register
Sensus ECR and ICE Registers
Neptune PRORead, AUTORead, E-Coder Registers
Red
Red
Red
Red
Black
Green/White
Green/White
Green
Green
Red
Black
Black
Black
Black
Green
Table 1. Mi.Node M Meter Interconnect
3.4 Verification
Following installation the Mi.Tech Hand-held should be used to verify proper installation
and operation. Please refer to the Mi.Tech manual.
4. Maintenance
There are no user serviceable items within a Mi.Node M. The battery is sealed within the
module and is not replaceable. No cleaning is required.
5. Product Labeling
5.1 Product and FCC/IC Identification
This label is affixed to the face of the Mi.Node M unit. This allows the installer to
easily scan the label with the Mi.Tech handheld computer during the installation
process. This label includes the Date of Manufacture, the Hardware Version and the
Mi.Node M/Serial Number (Node ID) that is used to uniquely address the device and
Assembled in USA. The FCC ID is SM6-MINODE-M.
Mueller Systems – Proprietary
Page 6
Mi.Node M Installation Manual
Figure 1. Sample Product Identification Label
5.2 IC Information
This AMI t r a n s m i t t e r , model Mi.Node M, operates in the license exempt 902 MHz to 928
MHz ISM band and is certified for operation in Canada. The IC ID is 9235A-MINODEM.
Information pertaining to the certification can be found on the web at
http://www.ic.gc.ca/eic/site/ceb-bhst.nsf/eng/home.
Mueller Systems – Proprietary
Page 7

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 7
Language                        : en-US
Tagged PDF                      : Yes
Author                          : Dan McGoldrick
Creator                         : Microsoft® Office Word 2007
Create Date                     : 2016:07:13 15:39:46-04:00
Modify Date                     : 2016:07:13 15:39:46-04:00
Producer                        : Microsoft® Office Word 2007
EXIF Metadata provided by EXIF.tools
FCC ID Filing: SM6-MINODE-M

Navigation menu