Multi Tech Systems 92U04A22750 Dual Band CDMA Wireless Modem User Manual
Multi Tech Systems Inc Dual Band CDMA Wireless Modem Users Manual
Users Manual
CDMA Embedded Data/Fax/Voice Wireless Modem MTMMC-C Developer’s Guide ModemModule Developer’s Guide MTMMC-C PN S000296B, Version B 10/17/03 Copyright This publication may not be reproduced, in whole or in part, without prior expressed written permission from Multi-Tech Systems, Inc. All rights reserved. Copyright © 2003, by Multi-Tech Systems, Inc. Multi-Tech Systems, Inc. makes no representations or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Furthermore, Multi-Tech Systems, Inc. reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of Multi-Tech Systems, Inc. to notify any person or organization of such revisions or changes. Revisions Revision Level Date 7/15/03 10/17/03 Description Initial release. Update mechanical dimensions drawing. Patents This device is covered by patent number 5,673,268. Trademarks Trademarks of Multi-Tech Systems, Inc. are ModemModule and the Multi-Tech logo. MNP and Microcom Network Protocol are registered trademarks of Microcom, Inc. Microsoft, Windows, and Windows NT are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. World Headquarters Multi-Tech Systems, Inc. 2205 Woodale Drive Mounds View, Minnesota 55112 Phone: 763-785-3500 or 800-328-9717 Fax: 763-785-9874 Technical Support Country By Email By Phone France: India: U.K.: U.S. and Canada: Rest of the World: support@multitech.fr support@multitechindia.com support@multitech.co.uk oemsales@multitech.com oemsales@multitech.com (33) 1-64 61 09 81 91 (124) 6340778 (44) 118 959 7774 (800) 972-2439 (763) 717-5863 Internet Address: http://www.multitech.com Wireless ModemModule MTMMC-C Developer's Guide Table of Contents CHAPTER 1 – PRODUCT DESCRIPTION AND SPECIFICATIONS ................................................................4 INTRODUCTION ...........................................................................................................................................................4 APPLICATIONS ............................................................................................................................................................4 PRODUCT FEATURES ...................................................................................................................................................5 FEATURE DESCRIPTIONS .............................................................................................................................................5 DEVELOPER’S KIT.......................................................................................................................................................6 TECHNICAL SPECIFICATIONS ......................................................................................................................................6 RELATED MANUALS ...................................................................................................................................................6 ADDITIONAL INFORMATION ........................................................................................................................................6 CHAPTER 2 – MECHANICAL SPECIFICATIONS..............................................................................................7 MECHANICAL DIMENSIONS.........................................................................................................................................7 CHAPTER 3 – ELECTRICAL CHARACTERISTICS...........................................................................................8 INTRODUCTION ...........................................................................................................................................................8 50-PIN CONNECTOR INTERFACES................................................................................................................................8 50-PIN CONNECTOR INTERFACES (CONTINUED) .........................................................................................................9 POWER CONSUMPTION..............................................................................................................................................11 HANDLING PRECAUTIONS .........................................................................................................................................11 CHAPTER 4 – INTERFACES .................................................................................................................................12 RF INTERFACE ..........................................................................................................................................................12 RF Connector .......................................................................................................................................................12 TRANSMITTER SPECIFICATIONS ................................................................................................................................12 RECEIVER SPECIFICATIONS .......................................................................................................................................13 CHAPTER 5 – TEST BOARD .................................................................................................................................14 TEST BOARD BLOCK DIAGRAM ................................................................................................................................17 CHAPTER 6 – APPLICATION CONSIDERATIONS..........................................................................................18 GENERAL GUIDELINES FOR THE USE OF THE MODEMMODULE .................................................................................18 Hardware and RF.................................................................................................................................................18 The Antenna..........................................................................................................................................................18 Firmware Upgrade...............................................................................................................................................18 Initial Configuration Using Mobile PhoneTools ..................................................................................................18 Getting Started .....................................................................................................................................................19 APPENDIX A – SAFETY PRECAUTIONS & REGULATORY STANDARDS COMPLIANCE....................20 SAFETY PRECAUTIONS ..............................................................................................................................................20 RF Safety ..............................................................................................................................................................20 General Safety ......................................................................................................................................................21 Safety Standards ...................................................................................................................................................22 RF Exposures .......................................................................................................................................................22 Instructions to OEMs............................................................................................................................................22 REGULATORY STANDARDS COMPLIANCE .................................................................................................................22 CDMA compliance ...............................................................................................................................................22 APPENDIX B – SOURCING GUIDE FOR CONNECTORS AND PERIPHERAL DEVICES........................23 CDMA ANTENNA.....................................................................................................................................................23 APPENDIX C – AT COMMAND LIST ..................................................................................................................24 Appendix D – Acronyms and Abbreviations.........................................................................................................29 INDEX ........................................................................................................................................................................30 Wireless ModemModule MTMMC-C Developer's Guide Chapter 1 – Product Description & Specification Chapter 1 – Product Description and Specifications Introduction The Multi-Tech ModemModule CDMA is a complete, ready-to-integrate, embedded data/fax/voice wireless modem packaged in a compact industrial chassis. Designed for global use, it offers standards-based multi-band CDMA2000 1x performance. This quick-to-market module allows developers to add wireless communication to products with a minimum of development time and expense. The ModemModule CDMA is based on industrystandard open interfaces, is fully type approved, and can be board-to-board or board-cable mounted. Multi-Tech’s Wireless ModemModule CDMA Product MTMMC-C Description CDMA2000 1xRTT, 800/1900 MHz Region Global The MTMMC-C ModemModule is used to integrate wireless data and fax communications in numerous embedded applications. This product is based on a Dual Band RF Module; every integrated module includes a CDMA 800/1900 MHz module. Applications With packet data speeds up to 153K bps, the ModemModule CDMA is targeted at applications that periodically need to send and receive data over a wireless network. It is an ideal solution for: · Appliances · Remote Diagnostics · ATM Terminals · Remote Metering · Automotive · Security Systems · Data Collection · Vending/Gaming Machines · Gas Pumps · Other devices requiring wireless connectivity. · Industrial and Medical Remote Monitoring Systems Note: The Wireless ModemModule must be mounted with at least 8 inches (20 cm) of clearance from the human body. Wireless ModemModule MTMMC-C Developer's Guide Chapter 1 – Product Description & Specification Product Features · CDMA2000 1xRTT operation · CDMA IS-95-A, IS-95B · Dual-band 800/1900 CDMA · Class 2.0 Group 3 FAX · Board-to-board or board-to-cable mounting · Short Message Service features including SMS mobile originated, SMS mobile terminated, cell broadcast, Over the Air Activation (OTA), OTASP, OTAPA · Voice features include DTMF, telephony, OCELP 13K, echo cancellation · MMCX antenna connector · 14.4K circuit-switched data · Serial interface supports DTE speeds to 230K · AT command compatible · Phone book management · Personal Information Management (PIM) · Fixed dialing number · Supplementary services including call forwarding, call barring, multiparty, call waiting and call hold, calling line identification, closed user group, call transfer · Real time clock · Alarm management Feature Descriptions Integration Reduces Space, Power and Cost. The ModemModule CDMA integrates the controller, RF transceiver, and antenna interface in one compact unit. This integration requires low power, low real estate and provides an overall reduction in costs. Reduces Development Time. The ModemModule CDMA can make your existing and next generation device, machine, or system, communication-ready without requiring significant hardware changes to its design. It actually provides faster time-to-market because it relieves the burden and expense of obtaining network and RF approvals. This complete, ready-to-integrate wireless module allows you to enhance your product while you focus on developing its core features. Voice Features. The ModemModule CDMA provides telephony and Dual Tone Multi Frequency (DTMF) functionality as well as QCELP (13K) and echo cancellation. Short Message Services. The ModemModule CDMA offers SMS features such cell broadcast, Over the Air Activation (OTA), OTASP, and OTAPA. The ModemModule CDMA is SMS Mobile as Originated and SMS Mobile Terminated. Compatible Supplementary Services. The ModemModule CDMA is compatible with supplementary services such as call forwarding, call barring, multiparty, call waiting and call hold, calling line identification, closed user group and call transfer. Management Features. The ModemModule CDMA provides advanced management features including phone book management, fixed dialing number, real-time clock and alarm management. Industry-standard Modem Commands. The ModemModule CDMA provides industry-standard AT-style commands for ease of integration into your existing software application. ModemModule Pin-Out. The ModemModule CDMA interfaces easily with existing products through a standard serial communication channel. The complete on-board RF transceiver interfaces with an antenna for direct connection to wireless SMS, circuit-switched dial-up, or packet data networks. The ModemModule is a Data Terminal Equipment (DTE) device with serial asynchronous protocol support. The serial DTE channel is capable of transfer speeds to 230K bps and can be interfaced directly to a UART or micro-controller. It can be board-toboard or board-to-cable mounted. Wireless ModemModule MTMMC-C Developer's Guide Chapter 1 – Product Description & Specification Developer’s Kit The ModemModule CDMA Developer’s Kit allows you to plug in the ModemModule and use it for testing, programming and evaluation. The kit includes one development board with RS-232 DB-25 connector, universal power supply, antenna and RS-232 cable. Technical Specifications Dimensions 2.5" w x 1.8" h x 0.5" d (6.4 cm x 4.6 cm x 1.2 cm) Weight 88 g Power Requirements 5 VDC; 400 mA typical, 700 mA maximum Operating temperature -30°C to + 60°C Storage temperature -35°C to +85°C Certifications CD Mark EMC: FCC Part 2, 15, 22, 24, EN55022 & EN55024 Safety: UL60950, EN60950 Casing Complete shielding-stainless steel/zinc Related Manuals At commands for this product are published in a separate document available on the Accessory Kit CD or from Multi-Tech. Multi-Tech manuals and other resources are available on the Multi-Tech Web page at http://www.multitech.com. Additional Information European Telecommunications Standards Institute (ETSI) - Contact the ETSI at: 650, route des Lucioles 06921 Sophia-Antipolis Cedex France Tel: +33 (0)4 92 94 42 00 Fax: +33 (0)4 93 65 47 16 http://www.etsi.org Global Engineering Documents manages a collection of more than one million documents from over 460 organizations worldwide: http://global.ihs.com Phone: 800-854-7179 Fax: 303-792-2192 The ITU is the leading publisher of telecommunication technology, regulatory and standards information, with over 4,000 titles in printed form, on CD-ROM and Online at http://www.itu.int/publications/ . Wireless ModemModule MTMMC-C Developer's Guide Chapter 2 – Mechanical Specifications Chapter 2 – Mechanical Specifications Mechanical Dimensions ModemModule Dimensions Wireless ModemModule MTMMC-C Developer's Guide Chapter 3 – Electrical Characteristics Chapter 3 – Electrical Characteristics Introduction This chapter describes the ModemModule’s electrical interfaces. These are: · 50-pin connector (power and data/signaling) · RF interface 50-Pin Connector Interfaces Pin # Name 10 11 GND GND +5V +5V CT109/DCD GND GPI04 SPK2N CT125/RI SPK2P Flashing LED 12 13 14 15 16 I/O I/O Type Supply Supply CMOS/2X I/O I/O CMOS/2X Analog CMOS/2X Analog CMOS/2X SPK1P CT106/CTS SPK1N ON/~OFF MIC2P Analog 1X Analog 17 18 AUXV0 MIC2N Analog Analog 19 20 ~RST MIC1P Analog 21 22 GND MIC1N Analog 23 24 25 BOOT GND CT103/TX 26 27 28 29 GPIO0 CT107/DSR CT104/RX CT108-2/DTR I/O 30 CT105/RTS Analog CMOS/2X 1X 1X Wireless ModemModule MTMMC-C Developer's Guide Description Comment GROUND GROUND High current High current High current High current Data Carrier Detect GROUND General Purpose I/O Speaker 2 negative output Ring Indicator Speaker 2 positive output Working mode indication LED Speaker 1 positive output Clear to Send Speaker 1 negative output Power ON/OFF control Microphone 2 positive input Auxiliary ADC input Microphone 2 negative input Reset active low Microphone 1 positive input Ground Microphone 1 negative input BOOT GROUND Transmit Data General Purpose I/O Data Set Ready Receive Data Data Terminal Ready Request to Send High current Driven by module ON = Vcc Open Collector Open Collector High Current Pull up with 100K-ohm when not used Pull up with 100K-ohm when not used Pull up with 100K-ohm when not used Chapter 3 – Electrical Characteristics 50-Pin Connector Interfaces (Continued) Pin # Name I/O I/O Type Description 31 32 33 COL3 COL4 COL1 I/O I/O I/O 1X 1X 1X Keypad column Keypad column Keypad column 34 COL2 I/O 1X Keypad column 35 ROW4 I/O 1X Keypad row 36 COL0 I/O 1X Keypad column 37 ROW2 I/O 1X Keypad row 38 ROW3 I/O 1X Keypad row 39 ROW0 I/O 1X Keypad row 40 ROW1 I/O 1X Keypad row 41 42 43 44 45 46 47 NC SPI_EN SPI_IO SPI_CLK SIMCLK SIMRST SIMVCC I/O 1X 1X 2X 2X 2X Not Connected SPI enable I C Data or SPI Data I C Clock or SPI Clock Clock for SIM interface Reset for SIM interface SIM card supply 48 SIMPRES 49 50 SIMDATA I/O 3X GPO0 * See SIM socket diagram in SIM interface section SIM card detect I/O for SIM interface General purpose I/O Comment 3V mode 3V mode 3V mode 6mA max. Connected to SIM connector pin 8. Pin 4 of SIM connector must be pulled down to GND with 1 K-Ohm* 3V mode ** GPO0 is a general purpose output for selection of external SIM, 3V or 5V. Wireless ModemModule MTMMC-C Developer's Guide Chapter 3 – Electrical Characteristics Operating Conditions Parameter I/O Type Min Max Vinput low CMOS -0.5V 0.8V Vinput high CMOS 2.1V 3.0V Voutput low 1X 0.2V IOL = -1mA 2X 0.2V IOL = -2mA 3X 0.2V IOL = -3mA Voutput high Condition 1X 2.6V IOH = 1mA 2X 2.6V IOH = 2mA 3X 2.6V IOH = 3mA 50-Pin Connector Wireless ModemModule MTMMC-C Developer's Guide 10 Chapter 3 – Electrical Characteristics 50 49 Pin Numbering – Bottom View Power Consumption Operating Mode Band CDMA RXTX Full Power CMA RXTX Average Power Cellular PCS Cellular PCS Cellular PCS CDMA Standby Average (mA) 615 770 340 445 20 20 Handling Precautions All devices must be handled with certain precautions to avoid damage due to the accumulation of static charge. Although input protection circuitry has been incorporated into the devices to minimize the effect of this static buildup, proper precautions should be taken to avoid exposure to electrostatic discharge during handling and mounting. Wireless ModemModule MTMMC-C Developer's Guide 11 Chapter 4 – Interfaces Chapter 4 – Interfaces This chapter describes the ModemModule interfaces. · External antenna · RF Interface RF Interface The impedance is 50 Ohms nominal. RF Connector The RF connector is MMCX standard type. An antenna can be directly connected through the mating connector or using a small adapter. Transmitter Specifications Transmitter performance test specification is CDMA2000 mobile station minimum requirement standard, 3GPP2 TSG C0011-A. Operating Frequency Modulation Conversion Method Oscillation Method RF Output Power Maximum Minimum Frequency Stability Open Loop Power Control Output Power RX= -25dBm RX= -65dBm RX= -104dBm Spurious Emission RX Band TX Band Other Frequency 824MHz ~ 849MHz (Cellular Band) 1850MHz ~ 1910MHz (PCS Band) QPSK Heterodyne VCTCXO & PLL Synthesizer 0.2W 10nW (-50dBm) +/- 300Hz TX= -57.5 ~ -38.5dBm TX= -17.5 ~ +1.5dBm TX= +18 ~ +30dBm -80dBm at 1MHz RBW -61dBm at 1MHz RBW -47dBm at 30KHz RBW Wireless ModemModule MTMMC-C Developer's Guide 12 Chapter 4 – Interfaces Receiver Specifications Receiver performance test specification is CDMA2000 mobile station minimum requirement standard, 3GPP2 TSG C.S0011-A. Operating Frequency Modulation Conversion Method Oscillation Method Receiver Sensitivity Single Tone Desensitization IMD Conducted Spurious Emission RX Band TX Band Other Frequency 869MHz ~ 894MHz (Cellular Band) 1930MHz ~ 1990MHz (PCS Band) QPSK Heterodyne VCTCXO & PLL Synthesizer -104dBm @ FER 0.5% -101dBm @ FER 1% (FC+/-1900KHz @ -30dBm) -101dBm @ FER 1% (FC+/-900KHz, FC+/-1700KHz @ -43dBm) -90dBm @ FER 1% (FC+/-900KHz, FC+/-1700KHz @ -36dBm) -79dBm @ FER 1% (FC+/-900KHz, FC+/-1700KHz @ -21dBm) -81dBm at 1MHz RBW -61dBm at 1MHz RBW -47dBm at 30KHz RBW Wireless ModemModule MTMMC-C Developer's Guide 13 Chapter 5 – Test Board Chapter 5 – Test Board Wireless ModemModule MTMMC-C Developer's Guide 14 Chapter 5 – Test Board Wireless ModemModule MTMMC-C Developer's Guide 15 Chapter 5 – Test Board Wireless ModemModule MTMMC-C Developer's Guide 16 Chapter 5 – Test Board Test Board Block Diagram Block Diagram Wireless ModemModule MTMMC-C Developer's Guide 17 Chapter 6 – Application Considerations Chapter 6 – Application Considerations General Guidelines for the Use of the ModemModule Hardware and RF · · · · · Ground plane: Multi-Tech recommends having a common ground plane for analog, digital and RF grounds. Bias of the Microphone inputs must be properly adjusted when using audio connectors (mic + speaker) 1. EMC protection on audio input/output (filters against 900 MHz) ESD protection on serial link Possible spurious emission radiated by the application to the RF receiver in the receiver band The Antenna The antenna sub-system and integration in the application is a major issue. It is a major issue in the choice of the antenna cable (type, length, performances, thermal resistance, etc.) These elements could affect CDMA performances such as sensitivity and emitted power. The antenna should be isolated as much as possible from the digital circuitry including the interface signals. Multi-Tech recommends shielding the terminal. On terminals including the antenna, a poor shielding could dramatically affect the sensitivity of the terminal. Subsequently, the power emitted through the antenna could affect the application. Firmware Upgrade The ModemModule firmware is stored in flash memory, and it can easily be upgraded. Contact the factory for details. Initial Configuration Using Mobile PhoneTools For Initial configuration of your wireless device, Multi-Tech offers a Windows-based mobile PhoneTools application. To load Mobile PhoneTools, click on the Mobile PhoneTools icon on the system CD and follow the on-screen prompts. Wireless ModemModule MTMMC-C Developer's Guide 18 Chapter 6 – Application Considerations Getting Started Minimum Hardware Interface Required To Get Started At a minimum, it is necessary to connect the following signals too properly operate the ModemModule: Pin Number Name Description GND Ground GND Ground +5V Power Supply +5V Power Supply GND Ground 13 CT106/CTS Clear to Send 15 ON/OFF Power On/Off * 21 GND Ground 24 GND Ground 25 CT103/TX Transmit 28 CT104/RX Receive 30 CT105/RTS Request to Send * Connected to +5V for example The serial link signals must be used through the implementation of the serial link level shifter. See “Level Shifter Application Diagram for Serial Link.” Terminal Emulator Setup Here below is an example based on the WindowsTM Hyperterminal application (terminal emulator program). Setup: 1. Go to START – PROGRAMS – ACCESSORIES – HYPERTERMINAL. 2. Start the Hyperterminal software. 3. Give the name of your choice, click on the icon of your choice, and click “OK.” 4. Choose these operating parameter values: Connect using: direct to COM1 Properties: 115200 bps; 8 bits data; no parity; 1 stop bit; hardware flow control. 5. Click “OK.” Once Hyperterminal is open and configured, it can be used to send AT commands to the ModemModule. For assistance in testing your ModemModule, see the examples in the AT Command manual for Multi-Tech’s CDMA wireless modem products (CDMA AT Commands Reference Guide). Wireless ModemModule MTMMC-C Developer's Guide 19 Appendix A – Safety Precautions & Regulatory Standards compliance Appendix A – Safety Precautions & Regulatory Standards Compliance Safety Precautions IMPORTANT! FOR THE EFFICIENT AND SAFE OPERATION OF YOUR CDMA INTEGRATED MODEM READ THIS INFORMATION BEFORE USE. RF Safety General Your ModemModule is based on the CDMA standard for cellular technology. Your modem is actually a low power radio transmitter and receiver. It sends out and receives radio frequency energy. When you use your ModemModule integrated modem, the cellular system that handles your calls controls both the radio frequency and the power level of your cellular modem. Exposure to RF Energy There has been some public concern about possible health effects of using CDMA modems. Although research on health effects from RF energy has focused on the current RF technology for many years, scientists have begun research regarding newer radio technologies, such as CDMA. After existing research had been reviewed, and after compliance to all applicable safety standards had been tested, it has been concluded that the product was fitted for use. If you are concerned about exposure to RF energy there are things you can do to minimize exposure. Obviously, limiting the duration of your calls will reduce your exposure to RF energy. In addition, you can reduce RF exposure by operating your cellular modem efficiently by following the below guidelines. Efficient Modem Operation For your modem to operate at the lowest power level, consistent with satisfactory call quality: · If your modem has an extendible antenna, extend it fully. Some models allow you to place a call with the antenna retracted. However your modem operates more efficiently with the antenna fully extended. · Do not hold the antenna when the modem is « IN USE ». Holding the antenna affects call quality and may cause the modem to operate at a higher power level than needed. Antenna Care and Replacement Do not use the modem with a damaged antenna. If a damaged antenna comes into contact with the skin, a minor burn may result. Replace a damaged antenna immediately. Consult your manual to see if you may change the antenna yourself. If so, use only a manufacturer-approved antenna. Otherwise, have your antenna repaired by a qualified technician. Use only the supplied or approved antenna. Unauthorized antennas, modifications or attachments could damage the modem and may contravene local RF emission regulations or invalidate type approval. Wireless ModemModule MTMMC-C Developer's Guide 20 Appendix A – Safety Precautions & Regulatory Standards compliance General Safety Driving Check the laws and the regulations regarding the use of cellular devices in the area where you have to drive as you always have to comply with them. When using your modem while driving, please: give full attention to driving, pull off the road and park before making or answering a call if driving conditions so require. Electronic Devices Most electronic equipment, for example in hospitals and motor vehicles is shielded from RF energy. However RF energy may affect some improperly shielded electronic equipment. Vehicle Electronic Equipment Check your vehicle manufacturer representative to determine if any on-board electronic equipment is adequately shielded from RF energy. Medical Electronic Equipment Consult the manufacturer of any personal medical devices (such as pacemakers, hearing aids, etc...) to determine if they are adequately shielded from external RF energy. Turn your modem OFF in health care facilities when any regulations posted in the area instruct you to do so. Hospitals or health care facilities may be using RF monitoring equipment. Aircraft Turn your modem OFF before boarding any aircraft. · Use it on the ground only with crew permission. · Do not use it in the air. To prevent possible interference with aircraft systems, Federal Aviation Administration (FAA) regulations require you to have permission from a crewmember to use your modem while the aircraft is on the ground. To prevent interference with cellular systems, local RF regulations prohibit using your modem while airborne. Children Do not allow children to play with your modem. It is not a toy. Children could hurt themselves or others (by poking themselves or others in the eye with the antenna, for example). Children could damage the modem, or make calls that increase your modem bills. Blasting Areas To avoid interfering with blasting operations, turn your unit OFF when in a « blasting area » or in areas posted: « turn off two-way radio ». Construction crews often use remote control RF devices to set off explosives. Potentially Explosive Atmospheres Turn your modem OFF when in any area with a potentially explosive atmosphere. It is rare, but your modem or its accessories could generate sparks. Sparks in such areas could cause an explosion or fire resulting in bodily injuries or even death. Areas with a potentially explosive atmosphere are often, but not always, clearly marked. They include fueling areas such as petrol stations; below decks on boats; fuel or chemical transfer or storage facilities; and areas where the air contains chemicals or particles, such as grain, dust, or metal powders. Do not transport or store flammable gas, liquid, or explosives, in the compartment of your vehicle that contains your modem or accessories. Before using your modem in a vehicle powered by liquefied petroleum gas (such as propane or butane) ensure that the vehicle complies with the relevant fire and safety regulations of the country in which the vehicle is to be used. Wireless ModemModule MTMMC-C Developer's Guide 21 Appendix A – Safety Precautions & Regulatory Standards compliance Safety Standards THIS WIRELESS MODEMMODULE COMPLIES WITH ALL APPLICABLE RF SAFETY STANDARDS. This cellular modem meets the standards and recommendations for the protection of public exposure to RF electromagnetic energy established by governmental bodies and other qualified organizations, such as the following: · Directives of the European Community, · Directorate General V in Matters of Radio Frequency Electromagnetic Energy RF Exposures Pursuant to 47 CFR § 24.52 of the FCC Rules and Regulations, personal communications services (PCS) equipment is subject to the radio frequency radiation exposure requirements specified in § 1.1307(b), § 2.1091 and § 2.1093 as appropriate. The Multi-Tech ModemModule is a CDMA (PCS 1900) terminal which operates in the US licensed PCS frequency spectrum. The device transmits over the 1850-1910 MHz band and receives over the 1930-1990 MHz Band. Mult-Tech Systems, Inc. certifies that it has determined that the Modem complies with the RF hazard requirements applicable to broadband PCS equipment operating under the authority of 47 CFR Part 24, Subpart E of the FCC Rules and Regulations. This determination is dependent upon installation, operation and use of the equipment in accordance with all instructions provided. The Modem is designed for and intends to be used in fixed and mobile applications. "Fixed" means that the device is physically secured at one location and is not able to be easily moved to another location. "Mobile" means that the device is designed to be used in other than fixed locations and generally in such a way that a separation distance of at least 20cm is normally maintained between the transmitter's antenna and the body of the user or nearby persons. The Modem is not designed for or intends to be used in portable applications (within 20 cm of the body of the user) and such uses are strictly prohibited. To ensure that the unit complies with current FCC regulations limiting both maximum RF output power and human exposure to radio frequency radiation, a separation distance of at least 20cm must be maintained between the unit's antenna and the body of the user and any nearby persons at all times and in all applications and uses. Finally, the tune-up procedure for the O9EM2113 ensures that the maximum RF output power of the device does not exceed 30.0 dBm within the variations that can be expected due to quantity production and testing on a statistical basis. Instructions to OEMs The Multi-Tech product manual includes specific warnings and cautions in order to ensure that OEMs are aware of their responsibilities, with regards to RF exposure compliance, for products into which the modem is integrated. With this guidance, the OEM will be able to incorporate into their documentation the necessary operating conditions and warnings. OEMs need to provide a manual with the ‘’final’’ product that clearly states the operating requirements and conditions and that these must be observed to ensure compliance with current FCC RF exposure requirements / MPE limits (see the “RF Exposures” section above). This will enable the OEM to generate (and provide the enduser with) the appropriate operating instructions, warnings and cautions, and/or markings for their product. Regulatory Standards Compliance CDMA compliance The ModemModule is in compliance with reference regulations: TBR 19, TBR 20, TBR 31, TBR 32. CE Label The Wireless ModemModule is CE compliant, which implies that the modem is in conformity with the European Community directives and it bears the CE label. Wireless ModemModule MTMMC-C Developer's Guide 22 Appendix B – Sourcing Guide for Connectors/Peripherals Appendix B – Sourcing Guide for Connectors and Peripheral Devices CDMA Antenna The integrated modem antenna connector is a MMCX connector. The MMCX connector incorporates a 'Snap On' latching action in order to make the connection easier with an excellent RF performance. An additional advantage is its small physical size, which is 50% of the standard MCX connector. This type of connector is suitable for the standard ranges of flexible and semi-rigid cables. The characteristic impedance of the MMCX coaxial connector is 50 ohm. The antenna manufacturer must guarantee that the antenna will be working according to the radio characteristics presented in the table below. Radio Characteristics CDMA 850 CDMA 1900 Frequency RX 869 to 894 MHz 1930 to 1990 MHz Frequency TX 824 to 849 MHz 1850 to 1910 MHz Impedance 50 ohms VSWR Typical Radiated Gain <1.5 0 dBi in at least one direction MMCX Plug The ModemModule requires an MMCX plug to connect to an antenna. MMCX Connector Example (right angle type) Antenna An antenna with matting connector can be ordered, for example, from: IMS Connectors Systems GMBH http://www.imscs.com/ MMCX / SMA Adapter A small MMCX / SMA adapter can be ordered, for example, from: Amphenol http://www.amphenol.com/ Order No: 908-31100 Wireless ModemModule MTMMC-C Developer's Guide 23 Appendix D – Acronyms and Abbreviations Appendix C – AT Command List For comprehensive information about AT Commands, please read the AT Command Manual. AT Command List General Commands +CGMI Manufacturer Identification +CGMM Request Model Identification +CGMR Request Revision Identification +CGSN Product Serial Number +CSCS Select TE Character Set +CIMI Request IMSI +CCID Card Identification +GCAP Capabilities List A/ Repeat Last Command +CPOF Power Off +CFUN Set Phone Functionality +CPAS Phone Activity Status +CMEE Report Mobile Equipment Errors +CKPD Keypad Control +CCLK Clock management +CALA Alarm management Wireless ModemModule MTMMC-C Developer's Guide 24 Appendix D – Acronyms and Abbreviations AT Command List (cont’d) Call Control Commands Dial command Hang-up Command Answer a Call +CEER Extended Error Report +VTD, +VTS DTMF Signals ATDL Redial Last Telephone Number AT%Dn Automatic Dialing (or SMS send) with DTR ATSO Automatic Answer +CICB Incoming Call Bearer +VGR, +VGT Gain Control +CMUT Microphone Mute Control +SPEAKER Speaker and Microphone Selection +ECHO Echo Cancellation +SIDET Side Tone Modification +VIP Initialize Voice Parameters +CSNS Single Numbering Scheme Network Service Commands +CSQ Signal Quality +COPS Operator Selection +CREG Network Registration +WOPN Read Operator Name +CPOL Preferred Operator List Security Commands +CPIN Enter PIN +CPIN2 Enter PIN2 +CPINC PIN Remaining Attempt Number +CLCK Facility Lock +CPWD Change Password Phone Book Commands +CPBS Select Phone Book Memory Storage +CPBR Read Phone Book Entries +CPBF Find Phone Book Entries +CPBW White Phone Book Entry +CPBP Phone Book Phone Search +CPBN Move Action in Phone Book +CNUM Subscriber Number +WAIP Avoid Phone Book Init Wireless ModemModule MTMMC-C Developer's Guide 25 Appendix D – Acronyms and Abbreviations AT Command List (cont’d) Short Message Commands +CSMS +CNMA +CPMS +CMGF +CSAS +CRES +CSDH +CNMI +CMGR +CMGL +CMGS +CMGW +CMSS +CSMP +CMGD +CSCA +CSCB +WCBM +WMSC +WMGO Select Message Service New Message Acknowledgement Preferred Message Storage Preferred Message Format Save Settings Restore Settings Show Text Mode parameters New Message Indication Read Message List Message Send Message Write Message to Memory Send Message from Storage Set Text Mode Parameters Delete Message Service Center Address Select Cell Broadcast Message Types Cell Broadcast Message Identifiers Message Status Modification Message Overwriting Supplementary Services Commands +CCFC +CLCK +CPWD +CCWA +CLIR +CLIP +COLP +CAOC +CACM +CAMM +CPUC +CHLD +CLCC +CSSN +CUSD +CCUG Call Forwarding Call Barring Modify SS Password Call Waiting Calling Line Identification Restriction Calling Line Identification Presentation Connected Line Identification Presentation Advice Of Charge Accumulated Call Meter Accumulated Call Meter Maximum Price Per Unit and Currency Table Call Related Supplementary Services List Current Calls Supplementary Service Notifications Unstructured Supplementary Service Data Closed User Group Data Commands +CBST +FCLASS +CR +CRC +ILRR +CRLP +DOPT %C +DS +DR \N Bearer Type Selection Select Mode Service Reporting Control Cellular Result Codes DTE-DCE Local Rate Reporting Radio Link Protocol Parameters Others Radio Link Parameters Select Data Compression V42 bis Data Compression V42 bis Data Compression Report Select Data Error Correcting Mode Wireless ModemModule MTMMC-C Developer's Guide 26 Appendix D – Acronyms and Abbreviations AT Command List (cont’d) Fax Commands +FTM +FRM +FTH +FRH +FTS +FRS Transmit Speed Receive Speed HDLC Transmit Speed HDLC Receive Speed Stop Transmission and Wait Receive Silence Fax Class 2 Commands +FDT +FDR +FET +FPTS +FK +FBOR +FBUF +FCQ +FCR +FDIS +FDCC +FLID +FPHCTO Transmit Data Receive Data Transmit Page Punctuation Page Transfer Status Parameters Terminate Session Page Transfer Bit Order Buffer Size Report Copy Quality Checking Capability to Receive Current Sessions Parameters DCE Capabilities Parameters Local ID String Page Transfer Timeout Parameter V24 - V25 Commands +IPR +ICF +IFC &C &D &S &W &T &F &V Fixed DTE Rate DTE-DCE Character Framing DTE-DCE Local Flow Control Set DCD Signal Set DTR Signal Set DSR Signal Back to Online Mode Result Code Suppression DCE Response Format Default Configuration Save Configuration Auto-Tests Echo Restore Factory Settings Display Configuration Request Identification Information Wireless ModemModule MTMMC-C Developer's Guide 27 Appendix D – Acronyms and Abbreviations AT Command List (cont’d) Specific AT Commands +CCED Cell Environment Description +CCED Automatic RxLev Indication +WIND General Indications +ADC Analog Digital Converters Measurements +CMER Mobile Equipment Event Reporting +WLPR Read Language Preference +WLPW Write Language Preference +WIOR Read GPIO Value +WIOW Write GPIO Value +WAC Abort Command +WTONE Play Tone +WDTMF Play DTMF Tone +WDWL Multi-Tech Downloading +WVR Multi-Tech Voice Rate +WDR Data Rate +WHWV Hardware Version +WDOP Date Of Production +WSVG Multi-Tech Select Voice Gain +WSTR Multi-Tech Status Request +WSCAN Multi-Tech Scan +WRIM Ring Indicator Mode +W32K Power saving mode Wireless ModemModule MTMMC-C Developer's Guide 28 Appendix D – Acronyms and Abbreviations Appendix D – Acronyms and Abbreviations ADC : Analog Digital Converter ASIC : Application Specific Integrated Circuit BCCH : Broadcast Control Channel CE : Communauté Européenne CLK : Clock CTS : Clear To send dB : decibel DCD : Data Carrier Detect DCE : Data Circuit Terminating Equipment DSR : Data Set Ready DTE : Data Terminal Equipment DTR : Data Terminated Ready EFR : Enhanced Full Rate EMC : Electromagnetic Conformity EN : Enable ETSI : European Telecommunications Standards Institute FAC : Final Assembly Code FR : Full-Rate FTA : Full Type Approval GND : Ground GPIO : General Purpose Input Output HR : Half-Rate MO : Mobile Originated MT : Mobile Terminated OEM : Original Equipment Manufacturer PDA : Personal Digital Assistant PCB : Printed Circuit Board PRES : Presence RI : Ring Indicator RTS : Request To Send SIM : Subscriber Identity Module SMD : Surface Mounted Design SMS : Short Message Service TAC : Type Approval Code TDMA : Time Code Multiple Access TE : Terminal Equipment VSWR : Voltage Standing Wave Ratio WAP : Wireless Application Protoc Wireless ModemModule MTMMC-C Developer's Guide 29 Index Index 1X ..................................................................9, 10, 11 2X ..................................................................9, 10, 11 3X ......................................................................10, 11 Advice Of Charge....................................................25 analog ................................................................17, 28 antenna...................................................17, 19, 20, 21 antenna cable ...........................................................17 AUXV0......................................................................9 BOOT ........................................................................9 Call Barring .............................................................25 Call Forwarding.......................................................25 Call Waiting.............................................................25 CDMA antenna........................................................22 CDMA Compliance.................................................21 CE ......................................................................21, 28 Cell Broadcast .........................................................25 Class 10 .....................................................................6 Closed User Group ..................................................25 CMOS..................................................................9, 11 column .....................................................................10 connector .............................................................9, 10 data ..............................................................5, 6, 9, 18 Data Carrier Detect..................................................28 dB ............................................................................28 digital.......................................................................17 EFR..........................................................................28 Electrical Characteristics ...........................................9 EMC protection .......................................................17 ESD protection ........................................................17 ETSI.........................................................................28 fax ..............................................................................5 FR ............................................................................28 gain ..........................................................................21 general purpose....................................................9, 10 GND ........................................................9, 10, 18, 28 GPIO..................................................................27, 28 GPRS .........................................................................1 ground plane ............................................................17 CDMA .....................................................6, 17, 19, 21 hardware ..............................................................6, 18 Wireless ModemModule MTMMC-C Developer’s Guide HR ...........................................................................28 I/O..................................................................9, 10, 11 interface .....................................................6, 9, 10, 17 MIC1N.......................................................................9 MIC1P .......................................................................9 MIC2N.......................................................................9 MIC2P .......................................................................9 MMCX (Miniature Micro Connector) .....................22 MO.....................................................................21, 28 modem .........................................................19, 20, 21 module .......................................................................9 MT ...........................................................................28 OFF................................................................9, 18, 20 ON/~OFF...................................................................9 operating conditions ................................................21 PCB .........................................................................28 PCS..........................................................................21 power .......................................................9, 17, 19, 21 Power Consumption ................................................12 radio.............................................................19, 20, 21 Radio Characteristics ...............................................22 RF ......................................................9, 17, 19, 20, 21 RST............................................................................9 serial link ...........................................................17, 18 signal........................................................................13 SIM....................................................................10, 28 SIMCLK ..................................................................10 SIMDATA...............................................................10 SIMPRES ................................................................10 SIMRST...................................................................10 SIMVCC..................................................................10 SMS ...................................................................24, 28 socket.......................................................................10 speaker.....................................................................17 SPI ...........................................................................10 SPK1N.......................................................................9 SPK1P .......................................................................9 terminal........................................................17, 18, 21 Vcc.............................................................................9 WAP ........................................................................28 30
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Modify Date : 2004:02:10 10:01:43-08:00 Create Date : 2003:10:20 16:42:50Z Page Count : 30 Creation Date : 2003:10:20 16:42:50Z Mod Date : 2004:02:10 10:01:43-08:00 Producer : Acrobat Distiller 5.0.5 (Windows) Author : Dee Ann Read Metadata Date : 2004:02:10 10:01:43-08:00 Creator : Dee Ann Read Title : Chapter 1 – Product Description and Specifications Page Mode : UseNoneEXIF Metadata provided by EXIF.tools