Multi Tech Systems 92U13A16855 MultiModem rCell 100Series Router User Manual tmp eHez6D
Multi Tech Systems Inc MultiModem rCell 100Series Router tmp eHez6D
Contents
- 1. User manual
- 2. User Guide
User Guide
MultiConnect® rCell 100 Series Router User Guide MULTICONNECT® RCELL 100 SERIES ROUTER USER GUIDE MultiConnect® rCell 100 Series Router User Guide Model: MTR-EV3 Part Number: S000582 Version: 1.0.4 Copyright This publication may not be reproduced, in whole or in part, without the specific and express prior written permission signed by an executive officer of Multi-Tech Systems, Inc. All rights reserved. Copyright © 2014 by Multi-Tech Systems, Inc. Multi-Tech Systems, Inc. makes no representations or warranties, whether express, implied or by estoppels, with respect to the content, information, material and recommendations herein and specifically disclaims any implied warranties of merchantability, fitness for any particular purpose and noninfringement. Multi-Tech Systems, Inc. reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of Multi-Tech Systems, Inc. to notify any person or organization of such revisions or changes. Legal Notices The Multi-Tech products are not designed, manufactured or intended for use, and should not be used, or sold or re-sold for use, in connection with applications requiring fail-safe performance or in applications where the failure of the products would reasonably be expected to result in personal injury or death, significant property damage, or serious physical or environmental damage. Examples of such use include life support machines or other life preserving medical devices or systems, air traffic control or aircraft navigation or communications systems, control equipment for nuclear facilities, or missile, nuclear, biological or chemical weapons or other military applications (“Restricted Applications”). Use of the products in such Restricted Applications is at the user’s sole risk and liability. MULTI-TECH DOES NOT WARRANT THAT THE TRANSMISSION OF DATA BY A PRODUCT OVER A CELLULAR COMMUNICATIONS NETWORK WILL BE UNINTERRUPTED, TIMELY, SECURE OR ERROR FREE, NOR DOES MULTI-TECH WARRANT ANY CONNECTION OR ACCESSIBILITY TO ANY CELLULAR COMMUNICATIONS NETWORK. MULTI-TECH WILL HAVE NO LIABILITY FOR ANY LOSSES, DAMAGES, OBLIGATIONS, PENALTIES, DEFICIENCIES, LIABILITIES, COSTS OR EXPENSES (INCLUDING WITHOUT LIMITATION REASONABLE ATTORNEYS FEES) RELATED TO TEMPORARY INABILITY TO ACCESS A CELLULAR COMMUNICATIONS NETWORK USING THE PRODUCTS. Contacting Multi-Tech Knowledge Base The Knowledge Base provides immediate access to support information and resolutions for all Multi-Tech products. Visit http://www.multitech.com/kb.go. Support Portal To create an account and submit a support case directly to our technical support team, visit: https://support.multitech.com. Support Business Hours: M-F, 8am to 5pm CT Country By Email By Phone Europe, Middle East, Africa: support@multitech.co.uk +(44) 118 959 7774 U.S., Canada, all others: support@multitech.com (800) 972-2439 or (763) 717-5863 Warranty To read the warranty statement for your product, visit www.multitech.com/warranty.go. For other warranty options, visit www.multitech.com/es.go. World Headquarters Multi-Tech Systems, Inc. 2205 Woodale Drive, Mounds View, MN 55112 Phone: (800) 328-9717 or (763) 785-3500 Fax (763) 785-9874 MultiConnect® rCell 100 Series Router User Guide CONTENTS Contents Product Overview .................................................................................................................................................... 5 About MultiConnect rCell 100 Series Router................................................................................................................ 5 Documentation ........................................................................................................................................................... 5 Descriptions of LEDs...................................................................................................................................................... 6 Ethernet LED Descriptions ........................................................................................................................................... 6 Side Panels .................................................................................................................................................................... 7 Specifications ................................................................................................................................................................ 8 Dimensions.................................................................................................................................................................. 10 Power Draw MTR-EV3................................................................................................................................................. 11 Safety Warnings..................................................................................................................................................... 12 Lithium Battery ........................................................................................................................................................... 12 Ethernet Ports ............................................................................................................................................................. 12 Radio Frequency (RF) Safety ....................................................................................................................................... 12 Interference with Pacemakers and Other Medical Devices ...................................................................................... 12 Potential interference ............................................................................................................................................... 12 Precautions for pacemaker wearers ........................................................................................................................ 13 Antenna....................................................................................................................................................................... 13 Important Safety Instructions ..................................................................................................................................... 13 Instructions de sécurité importantes.......................................................................................................................... 13 Cellular Information............................................................................................................................................... 15 Antenna System Cellular Devices................................................................................................................................ 15 Requirements for Cellular Antennas with regard to FCC/IC Compliance ................................................................. 15 EV-DO and CDMA Antenna Information..................................................................................................................... 15 EV-DO and CDMA Authorized Antennas................................................................................................................... 15 EV-DO and CDMA Antenna Requirements .............................................................................................................. 15 Installing and Using the Router .............................................................................................................................. 16 Installing the Router.................................................................................................................................................... 16 Mounting the Device................................................................................................................................................... 16 Activating the Account for Wireless Devices ............................................................................................................. 16 Setting up GPS............................................................................................................................................................. 17 Resetting the Device ................................................................................................................................................... 17 Restoring User Defined Settings to the Device........................................................................................................... 17 Resetting the Device to Factory Defaults .................................................................................................................. 17 Regulatory Information.......................................................................................................................................... 18 Notice for Devices that Use Aeris Radios.................................................................................................................... 18 47 CFR Part 15 Regulation Class B Devices ................................................................................................................. 18 Industry Canada Class B Notice................................................................................................................................... 18 MultiConnect® rCell 100 Series Router User Guide CONTENTS FCC Interference Notice .............................................................................................................................................. 19 Restriction of the Use of Hazardous Substances (RoHS) ............................................................................................ 20 REACH Statement ....................................................................................................................................................... 21 Registration of Substances........................................................................................................................................ 21 Substances of Very High Concern (SVHC) ................................................................................................................ 21 Waste Electrical and Electronic Equipment Statement .............................................................................................. 21 WEEE Directive.......................................................................................................................................................... 21 Instructions for Disposal of WEEE by Users in the European Union ........................................................................ 21 Information on HS/TS Substances According to Chinese Standards ......................................................................... 22 Information on HS/TS Substances According to Chinese Standards (in Chinese) ...................................................... 23 MultiConnect® rCell 100 Series Router User Guide PRODUCT OVERVIEW Product Overview About MultiConnect rCell 100 Series Router This guide describes the MultiConnect rCell 100 Series router. The rCell family of routers is carrier approved and ready-to-deploy. You can use your device to provide secure data communication between many types of devices that use legacy as well as the latest communication technologies. Some device models support: ■ GPS The router has an integrated cellular modem and includes 10/100 BaseT Ethernet and RS-232 serial connectivity. An image of the device follows: Documentation The following table describes additional documentation for your device. The documentation is available on the Multi-Tech Installation Resources website at www.multitech.com/setup/product.go. Document Description User Guide This document. Provides an overview, safety and regulatory information, schematics and general device information. API guide You can use the rCell API to manage configurations, poll statistics, and issue commands. The design, patterns, and methods are documented in the API Guide part number S000576. AT Commands This document describes AT commands that are available for your device. These commands are documented in the Reference Guide part number S000546. MultiConnect® rCell 100 Series Router User Guide PRODUCT OVERVIEW Descriptions of LEDs The top panel contains the following LEDs: ■ Power and Status LEDs—The Power LED indicates that DC power is present and the Status LED blinks when the unit is functioning normally. ■ Modem LEDs—Two modem LEDs indicate carrier detection and link status. ■ Signal LEDs—Three signal LEDs display the signal strength level of the wireless connection. ■ Ethernet LEDs—These LEDs are not on the top panel. See the section Ethernet LED Descriptions for descriptions of these LEDs. LED Indicators POWER Indicates presence of DC power when lit. STATUS The LED is a solid light when the device is booting up, saving the configuration, restarting, or updating the firmware. When the Status LED begins to blink, the router is ready for use. CD Carrier Detect. When lit, indicates data connection has been established. LS Link Status OFF—There is no power to the cellular radio. Continuously Lit—Powered, connected and transmitting and receiving data. Slow Blink (-0.2Hz) —Powered, connected and idle. Faster Blink (-3Hz)— Powered and searching for a connection. SIGNAL Signal strength for cellular. ALL OFF—Unit is off, not registered on network, or extremely weak signal (0 < = RSSI < 6). 1 Bar “ON”—Very weak signal (7 < = RSSI <14). 1 Bar and 2 Bar “ON”—Weak signal (15 < = RSSI <23). 1 Bar, 2 Bar, and 3 Bar “ON”—Good signal (24 <= RSSI > = 31). Ethernet LED Descriptions Two Ethernet LEDs are physically on the RJ-45 connector(s). The table that follows describes these LEDs. Ethernet Link Right LED on Ethernet connector. Blinks when there is transmit and receive activity on the Ethernet link. It shows a steady light when there is a valid Ethernet connection. Ethernet Speed Left LED on Ethernet connector. Lit when the Ethernet is linked at 100 Mbps. If it is not lit, the Ethernet is linked at 10 Mbps. MultiConnect® rCell 100 Series Router User Guide PRODUCT OVERVIEW Side Panels The device has connectors on either side. The figures that follow show the connectors available on your model. A side panel of the device follows: Not all models have a GPS connector. The figure that follows shows the other side of the device. MultiConnect® rCell 100 Series Router User Guide PRODUCT OVERVIEW Specifications MTR-EV3 Category Description General Performance CDMA2000 1xRTT EV-DO Rev. A (backward compatible to EV-DO Rev. 0 and CDMA 1x networks) Frequency Bands Dual-Band 800/1900 MHz Radio Cellular Telit DE910-DUAL Speed Packet Data Up to 3.1 Mbps downlink Up to 1.8 Mbps uplink SMS SMS Point-to-Point Messaging Mobile-Terminated SMS Mobile-Originated SMS Connectors Cellular Female SMA connectors for cellular GPS Female SMA connector WiFi Male SMA connector Power Requirements Voltage 7 V to 32 V DC Physical Description Dimensions Dimensions are shown in the section “Dimensions” that follows. Weight 8.2 ounces or 230 grams Environment Operating Temperature -40° C to +85° C Humidity Relative humidity 15% to 93% non-condensing Certifications, Compliance, Warranty MultiConnect® rCell 100 Series Router User Guide PRODUCT OVERVIEW Category EMC Compliance Description FCC Part 15B Safety Compliance UL 60950-1 Network Compliance Aeris Sprint Verizon Radio Compliance FCC Part 22 FCC Part 24 RSS 132 RSS 133 Warranty Two years *UL Listed @ 40° C, limited by power supply. UL Certification does not apply or extend to an ambient above 40° C and has not been evaluated by UL for ambient greater than 40° C. UL has evaluated this device for use in ordinary locations only. Installation in a vehicle or other outdoor locations has not been evaluated by UL. UL Certification does not apply or extend to use in vehicles or outdoor applications or in ambient above 40° C. Note: The radio’s performance may be affected at the temperature extremes. This is considered normal. There is no single cause for this function. Rather, it is the result of an interaction of several factors, such as the ambient temperature, the operating mode and the transmit power. MultiConnect® rCell 100 Series Router User Guide PRODUCT OVERVIEW Dimensions 10 MultiConnect® rCell 100 Series Router User Guide PRODUCT OVERVIEW Power Draw MTR-EV3 Cellular call box connection no data (amps) Average measured current (amps) at maximum power Peak TX amplitude current (amps) Total inrush charge measured in MilliCoulombs (mC) US Cellular 800 MHz 0.255 0.818 0.900 1.71 US PCS 1900 MHz 0.255 0.848 0.924 1.71 US Cellular 800 MHz 0.2 0.630 0.7 2.65 US PCS 1900 MHz 0.2 0.646 0.716 2.65 US Cellular 800 MHz 0.069 0.188 0.232 4.27 US PCS 1900 MHz 0.069 0.194 0.24 4.27 7 volts 9 volts 32 volts Peak Tx: The peak current during a CDMA connection transmitting data at max power. Maximum Power: The continuous current during maximum data rate with the radio transmitter at maximum power Inrush Charge: The total inrush charge at power on. MultiConnect® rCell 100 Series Router User Guide 11 SAFETY WARNINGS Safety Warnings Lithium Battery ■ A lithium battery located within the product provides backup power for the timekeeping. This battery has an estimated life expectancy of ten years. ■ When this battery starts to weaken, the date and time may be incorrect. If the battery fails, the board must be sent back to Multi-Tech Systems for battery replacement. ■ Lithium cells and batteries are subject to the Provisions for International Transportation. Multi-Tech Systems, Inc. confirms that the Lithium batteries used in the Multi-Tech product(s) referenced in this manual comply with Special Provision 188 of the UN Model Regulations, Special Provision A45 of the ICAOTI/IATA-DGR (Air), Special Provision 310 of the IMDG Code, and Special Provision 188 of the ADR and RID (Road and Rail Europe). CAUTION: Risk of explosion if this battery is replaced by an incorrect type. Dispose of batteries according to instructions. Attention: Pour réduire les risques d’incendie, utiliser uniquement des conducteurs de télécommunications 26 AWG au de section supérleure. Ethernet Ports CAUTION: Ethernet ports and command ports are not designed to be connected to a public telecommunication network. Radio Frequency (RF) Safety Due to the possibility of radio frequency (RF) interference, it is important that you follow any special regulations regarding the use of radio equipment. Follow the safety advice given below. ■ Operating your device close to other electronic equipment may cause interference if the equipment is inadequately protected. Observe any warning signs and manufacturers’ recommendations. ■ Different industries and businesses restrict the use of cellular devices. Respect restrictions on the use of radio equipment in fuel depots, chemical plants, or where blasting operations are in process. Follow restrictions for any environment where you operate the device. ■ Do not place the antenna outdoors. ■ Switch OFF your wireless device when in an aircraft. Using portable electronic devices in an aircraft may endanger aircraft operation, disrupt the cellular network, and is illegal. Failing to observe this restriction may lead to suspension or denial of cellular services to the offender, legal action, or both. ■ Switch OFF your wireless device when around gasoline or diesel-fuel pumps and before filling your vehicle with fuel. ■ Switch OFF your wireless device in hospitals and any other place where medical equipment may be in use. Interference with Pacemakers and Other Medical Devices Potential interference Radiofrequency energy (RF) from cellular devices can interact with some electronic devices. This is electromagnetic interference (EMI). The FDA helped develop a detailed test method to measure EMI of implanted cardiac 12 MultiConnect® rCell 100 Series Router User Guide SAFETY WARNINGS pacemakers and defibrillators from cellular devices. This test method is part of the Association for the Advancement of Medical Instrumentation (AAMI) standard. This standard allows manufacturers to ensure that cardiac pacemakers and defibrillators are safe from cellular device EMI. The FDA continues to monitor cellular devices for interactions with other medical devices. If harmful interference occurs, the FDA will assess the interference and work to resolve the problem. Precautions for pacemaker wearers If EMI occurs, it could affect a pacemaker in one of three ways: ■ Stop the pacemaker from delivering the stimulating pulses that regulate the heart's rhythm. ■ Cause the pacemaker to deliver the pulses irregularly. ■ Cause the pacemaker to ignore the heart's own rhythm and deliver pulses at a fixed rate. Based on current research, cellular devices do not pose a significant health problem for most pacemaker wearers. However, people with pacemakers may want to take simple precautions to be sure that their device doesn't cause a problem. ■ Keep the device on the opposite the side of the body from the pacemaker to add extra distance between the pacemaker and the device. ■ Avoid placing a turned-on device next to the pacemaker (for example, don’t carry the device in a shirt or jacket pocket directly over the pacemaker). Antenna The antenna intended for use with this unit meets the requirements for mobile operating configurations and for fixed mounted operations, as defined in 2.1091 and 1.1307 of the FCC rules for satisfying RF exposure compliance. If an alternate antenna is used, consult user documentation for required antenna specifications. Important Safety Instructions When using your telephone equipment, basic safety precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following: 1. 2. 3. Do not use this product near water, for example, near a bathtub, wash bowl, kitchen sink or laundry tub, in a wet basement or near a swimming pool. Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote risk of electric shock from lightning. Do not use the telephone to report a gas leak in the vicinity of the leak. SAVE THESE INSTRUCTIONS Instructions de sécurité importantes Des mesures de sécurité de base doivent toujours être prises lors de l'utilisation de l'équipement téléphonique afin de réduire les risques d'incendie, d'électrocution ou de blessures corporelles. Ces mesures sont les suivantes: 1. 2. 3. Ne pas utiliser ce produit à proximité de l'eau, comme par exemple près d'une baignoire, d'un bac de lavage, d'un évier ou d'une cuve à lessive, dans une cave humide ou près d'une piscine. Éviter d'utiliser un téléphone (autre que sans fil) pendant un orage. Il existe un léger risque d'électrocution par la foudre. Ne pas utiliser le téléphone pour signaler une fuite de gaz à proximité de celle-ci. MultiConnect® rCell 100 Series Router User Guide 13 SAFETY WARNINGS CONSERVEZ CES INSTRUCTIONS 14 MultiConnect® rCell 100 Series Router User Guide CELLULAR INFORMATION Cellular Information Antenna System Cellular Devices The cellular/wireless performance depends on the implementation and antenna design. The integration of the antenna system into the product is a critical part of the design process; therefore, it is essential to consider it early so the performance is not compromised. If changes are made to the device's certified antenna system, then recertification will be required by specific network carriers. Requirements for Cellular Antennas with regard to FCC/IC Compliance There cannot be any alteration to the authorized antenna system. The antenna system must maintain the same specifications. The antenna must be the same type, with similar in-band and out-of-band radiation patterns. This device has been designed to operate with the antennas listed below and having a maximum gain for 850 MHz of <= 6.4 dBi , for 1700 MHz of <= 6.5 dBi, and for 1900 MHz of <= 3 dBi. Antennas not included in this list or that have a gain greater than specified are strictly prohibited for use with this device. The required antenna impedance is 50 ohms. EV-DO and CDMA Antenna Information EV-DO and CDMA Authorized Antennas These devices were approved with the following antenna: Manufacturer: Exceltek Electronics Ltd. Manufacturer's Model Number: C0081-ANG0002 Multi-Tech ordering information: Model Quantity ANQB-1HRA ANQB-10HRA 10 ANQB-50HRA 50 EV-DO and CDMA Antenna Requirements Category Description Frequency Range 824 - 894 MHz / 1850 - 1990 MHz Impedance 50 Ohms VSWR VSWR should not exceed 2.0:1 at any point across the bands of operation Typical Radiated Gain 2 dBi on azimuth plane Radiation Omni-directional Polarization Linear vertical MultiConnect® rCell 100 Series Router User Guide 15 INSTALLING AND USING THE ROUTER Installing and Using the Router Installing the Router 1. 2. 3. 4. 5. 6. 7. 8. To use the router’s cellular features, connect a suitable antenna to the antenna connector. Using an Ethernet cable, connect one end of the cable to the ETHERNET connector on the back of the router and the other end to your computer, either directly or through a switch or hub. If you are connecting to a serial interface, connect the DE9 connector (9-pin) of the RS232 cable to the RS232 connector on the router, then connect the other end to the serial port on the desired device. Some routers support the use of a GPS receiver. If you are using a GPS receiver with the router, attach the GPS cable to the GPS connector on the router. Attach a power cable to your power supply module. Screw-on the power lead from the power supply module into the power connection on the router. Plug the power supply into your power source. The POWER LED lights after the device powers up. When the Status LED begins to blink, the device is ready for use. You can configure your router by using your router’s web management Interface. You might need to change the IP address of your computer to be in the same IP and subnet mask range as the device. a. b. c. d. Open an Internet browser. In the browser's address field, type the default address for the router: http://192.168.2.1. A login page opens. In the username field, type the default user name: admin (all lowercase). In the password field, type the default password: admin (all lower-case). Click Login. The Web Management Home page opens. Online documentation included with the web management interface describes how to configure your router Mounting the Device 1. 2. 3. Locate the groove on the bottom of the modem. Slide the mounting rod through the groove. To secure the rod to the desired surface, place and tighten two screws in the holes on either end of the mounting rod. The dimensions illustration in this guide shows the mounting rod, as well as the dimensions for placement of the screws. Activating the Account for Wireless Devices Refer to Multi-Tech’s Cellular Activation Web site at http://www.multitech.com/activation.go for information on activating your cellular modem. Note: If you need remote access to your MultiConnect device over the Internet for remote configuration, ensure that your wireless network provider has provisioned mobile terminated data and fixed or dynamic public IP address in which they can configure the network to redirect any incoming connection to that predefined IP. 16 MultiConnect® rCell 100 Series Router User Guide INSTALLING AND USING THE ROUTER Setting up GPS If your model can support a GPS, see the online help file for information on working with a GPS. Resetting the Device To reset the device, when desired: 1. 2. 3. 4. Find the hole in the panel labeled RESET. The reset button is recessed into the case. To access the reset button, find a pin or similar thin object that can fit through the reset hole. Use the pin to quickly press and release the RESET button. Release the pin from the reset button. The device reboots. Restoring User Defined Settings to the Device You can restore user defined settings to your device. 1. 2. 3. Find the hole in the panel labeled RESET. The reset button is recessed into the case. To access the reset button, find a pin or similar thin object that can fit through the reset hole. Use the pin to press in the button for about 3 seconds and then release the RESET button. The userdefined configuration settings are restored. Resetting the Device to Factory Defaults You can reset the device so that custom configuration settings are cleared and replaced with default configuration settings. Default settings can include OEM specific settings. To reset the device to factory default settings: 1. 2. 3. Press and Hold the button until the Status LED becomes solid. Release the button for the reset to complete The device reboots. MultiConnect® rCell 100 Series Router User Guide 17 REGULATORY INFORMATION Regulatory Information Notice for Devices that Use Aeris Radios One component of your device is a radio. A radio algorithm prevents your device from repeatedly attempting to connect to the network when the radio: ■ cannot establish a packet data connection or ■ fails to access the application server. When writing applications for your devices, ensure that your applications do not interfere with the radio's connection retry algorithm. If you fail to do so, Aeris might block network access for your devices. After your devices reach the end of their commercial lifespan, you must remove them from the Aeris network. To do so, remove power from the devices and remove their antennas. If your devices continue to attempt to register with the network after you cancel device subscriptions, Aeris can bill you for any traffic generated by those devices. 47 CFR Part 15 Regulation Class B Devices This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ■ Reorient or relocate the receiving antenna. ■ Increase the separation between the equipment and receiver. ■ Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ■ Consult the dealer or an experienced radio/TV technician for help. Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Industry Canada Class B Notice This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe B respecte toutes les exigences du Reglement Canadien sur le matériel brouilleur. This device complies with Industry Canada RSS Appliance radio exempt from licensing. The operation is permitted for the following two conditions: 1. 2. the device may not cause harmful interference, and the user of the device must accept any interference suffered, even if the interference is likely to jeopardize the operation. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: 18 MultiConnect® rCell 100 Series Router User Guide REGULATORY INFORMATION 1. 2. l'appareil ne doit pas produire de brouillage, et l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. FCC Interference Notice This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation MultiConnect® rCell 100 Series Router User Guide 19 REGULATORY INFORMATION Restriction of the Use of Hazardous Substances (RoHS) Multi-Tech Systems, Inc Certificate of Compliance 2011/65/EU Multi-Tech Systems confirms that its embedded products comply with the chemical concentration limitations set forth in the directive 2011/65/EU of the European Parliament (Restriction of the use of certain Hazardous Substances in electrical and electronic equipment - RoHS). These Multi-Tech products do not contain the following banned chemicals1: ■ Lead, [Pb] < 1000 PPM ■ Mercury, [Hg] < 1000 PPM ■ Hexavalent Chromium, [Cr+6] < 1000 PPM ■ Cadmium, [Cd] < 100 PPM ■ Polybrominated Biphenyl, [PBB] < 1000 PPM ■ Polybrominated Diphenyl Ether, [PBDE] < 1000 PPM Environmental considerations: ■ Moisture Sensitivity Level (MSL) =1 ■ Maximum Soldering temperature = 260C (in SMT reflow oven) Lead usage in some components is exempted by the following RoHS annex, therefore higher lead concentration would be found in some modules (>1000 PPM); - Resistors containing lead in a glass or ceramic matrix compound. 20 MultiConnect® rCell 100 Series Router User Guide REGULATORY INFORMATION REACH Statement Registration of Substances After careful review of the legislation and specifically the definition of an “article” as defined in EC Regulation 1907/2006, Title II, Chapter 1, Article 7.1(a)(b), it is our current view Multi-Tech Systems, Inc. products would be considered as “articles”. In light of the definition in § 7.1(b) which requires registration of an article only if it contains a regulated substance that “is intended to be released under normal or reasonably foreseeable conditions of use,” Our analysis is that Multi-Tech Systems, Inc. products constitute nonregisterable articles for their intended and anticipated use. Substances of Very High Concern (SVHC) Per the candidate list of Substances of Very High Concern (SVHC) published October 28, 2008 we have reviewed these substances and certify the Multi-Tech Systems, Inc. products are compliant per the EU “REACH” requirements of less than 0.1% (w/w) for each substance. If new SVHC candidates are published by the European Chemicals Agency, and relevant substances have been confirmed, that exceeds greater than 0.1% (w/w), MultiTech Systems, Inc. will provide updated compliance status. Multi-Tech Systems, Inc. also declares it has been duly diligent in ensuring that the products supplied are compliant through a formalized process which includes collection and validation of materials declarations and selective materials analysis where appropriate. This data is controlled as part of a formal quality system and will be made available upon request. Waste Electrical and Electronic Equipment Statement WEEE Directive The WEEE Directive places an obligation on EU-based manufacturers, distributors, retailers, and importers to takeback electronics products at the end of their useful life. A sister directive, ROHS (Restriction of Hazardous Substances) complements the WEEE Directive by banning the presence of specific hazardous substances in the products at the design phase. The WEEE Directive covers all Multi-Tech products imported into the EU as of August 13, 2005. EU-based manufacturers, distributors, retailers and importers are obliged to finance the costs of recovery from municipal collection points, reuse, and recycling of specified percentages per the WEEE requirements. Instructions for Disposal of WEEE by Users in the European Union The symbol shown below is on the product or on its packaging, which indicates that this product must not be disposed of with other waste. Instead, it is the user's responsibility to dispose of their waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service or where you purchased the product. July, 2005 MultiConnect® rCell 100 Series Router User Guide 21 REGULATORY INFORMATION Information on HS/TS Substances According to Chinese Standards In accordance with China's Administrative Measures on the Control of Pollution Caused by Electronic Information Products (EIP) # 39, also known as China RoHS, the following information is provided regarding the names and concentration levels of Toxic Substances (TS) or Hazardous Substances (HS) which may be contained in Multi-Tech Systems Inc. products relative to the EIP standards set by China's Ministry of Information Industry (MII). Hazardous/Toxic Substance/Elements Name of the Component Lead (PB) Mercury (Hg) Cadmium Hexavalent (CD) Chromium (CR6+) Polybromi Polybrominat nated ed Diphenyl Biphenyl Ether (PBDE) (PBB) Printed Circuit Boards Resistors Capacitors Ferrite Beads Relays/Opticals ICs Diodes/ Transistors Oscillators and Crystals Regulator Voltage Sensor Transformer Speaker Connectors LEDs Screws, Nuts, and other Hardware AC-DC Power Supplies Software /Documentation CDs Booklets and Paperwork Chassis X Represents that the concentration of such hazardous/toxic substance in all the units of homogeneous material of such component is higher than the SJ/Txxx-2006 Requirements for Concentration Limits. O Represents that no such substances are used or that the concentration is within the aforementioned limits. 22 MultiConnect® rCell 100 Series Router User Guide REGULATORY INFORMATION Information on HS/TS Substances According to Chinese Standards (in Chinese) 依照中国标准的有毒有害物质信息 根据中华人民共和国信息产业部 (MII) 制定的电子信息产品 (EIP) 标准-中华人民共和国《电子信息产品污染 控制管理办法》(第 39 号),也称作中国 RoHS, 下表列出了 Multi-Tech Systems, Inc. 产品中可能含有的有毒 物质 (TS) 或有害物质 (HS) 的名称及含量水平方面的信息。 有害/有毒物质/元素 成分名称 铅 (PB) 汞 (Hg) 镉 (CD) 六价铬 (CR6+) 多溴联苯 (PBB) 多溴二苯醚 (PBDE) 印刷电路板 电阻器 电容器 铁氧体磁环 继电器/光学部件 ICs 二极管/晶体管 振荡器和晶振 调节器 电压传感器 变压器 扬声器 连接器 LEDs 螺丝、螺母以及其它五金件 交流-直流电源 软件/文档 CD 手册和纸页 底盘 X 表示所有使用类似材料的设备中有害/有毒物质的含量水平高于 SJ/Txxx-2006 限量要求。 O 表示不含该物质或者该物质的含量水平在上述限量要求之内。 MultiConnect® rCell 100 Series Router User Guide 23
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Page Mode : UseOutlines XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Create Date : 2014:05:08 16:31:17-05:00 Creator Tool : TopLeaf 7.6.056 Modify Date : 2014:05:08 16:35:59-05:00 Metadata Date : 2014:05:08 16:35:59-05:00 Format : application/pdf Creator : Turn-Key Systems Pty Ltd Title : tmp_eHez6D Top Leaf-Version : Version=tlapi 7.6 56 2013/12/05 support@turnkey.com.au Top Leaf-Profile : default Producer : iText 2.1.7 by 1T3XT Document ID : uuid:bcd4ed19-5bac-4ee5-83cd-dbc0f6707ff7 Instance ID : uuid:d2275b19-fc62-456c-89a0-bc085e6f7536 Page Count : 23 Author : Turn-Key Systems Pty LtdEXIF Metadata provided by EXIF.tools