Multitone Electronics PLC IP133 Multitone I-Page – IP133 User Manual Multitone I PAGE

Multitone Electronics PLC Multitone I-Page – IP133 Multitone I PAGE

Contents

manual

        Multitone i-Page    User and   Installation Guide
 ISSUE CONTROL Issue Date Remarks 01 01.08.11 First Issue 02 25.10.11 Grammatical changes, removal of some pager images and addition of waterproof pager
i-Page USER AND INSTALLATION GUIDE   Index of contents  Important User Information  Section  Description                                                                                                     Page           1.0  Checking supplied equipment            2 2.0  Tools                  2 3.0  Equipment required               2 4.0  Assembly requirements              3 4.1    Assembly                  3 4.2  Mounting                  3 4.3  Power supply                                                                                            3 4.4  Network cable                                                                                                    4 4.5  Aerial fitting                                                                                                        4 5.0  i-Page setup                4 5.1  i-Page network setup – Changing IP address for use on local network  5 5.2  IP Settings - Set static IP address, Netmask, gateway, Syslog for i-Page  5 5.3  Language - Select browser and pager languages        6 5.4  Clock  - Set time and date            6 5.5  Paging setup - Set system address, paging format, time on/off, message   7   length and coverage test   5.6  Password - Set one administrator or five user passwords      7 5.7   Users  - Add, amend or delete users           7 5.8  Groups - Add and remove groups            8 5.9  Stored Messages - Add or remove stored messages up to 80 characters  8 5.10   DLC’s - Programme DLC alarm details          9 5.11  Serial port - Select serial port protocol          9 5.12  Backup/Restore - Backup and restore i-Page data        10 5.13  Factory reset - Reset i-Page to factory setting. Note that all system data is   10   destroyed   6.0   Engineering button – Temporarily restore default IP address      10 7.0    Paging users and groups - User interface for paging users and groups    11  7.1   Logout - Used to log out of Multitone i-Page          11 8.0  Syslog message tracking – Optional software form logging messages  11 9.0     Transmitter alignment – Changing the transmitter frequency      11 10.0   Software upgrades – Updating i-Page          12  Appendices Appendix 1  DLC alarm and serial port technical requirements        14 Appendix 2       Frequently asked questions and fault finding                                           15 Appendix 3  i-Page specifications                                                                               16 Appendix 4  Multitone Pagers                                                                                  17 Appendix 5  i-Page Spares                                                                            18
IMPORTANT USER INFORMATION  CAUTION THIS PRODUCT HAS NO REPLACEABLE COMPONENTS. ALL FAULTY UNITS SHOULD BE RETURNED TO MULTITONE OR THEIR AGENT, FOR REPAIR. FOR AVAILABLE SPARE PARTS, SEE APPENDIX 6.  STATIC SENSITIVE DEVICES ARE USED WITHIN THIS EQUIPMENT. OBSERVE STATIC SAFETY PRECAUTIONS IF CHANGING COMPONENTS.  ENSURE THE UNIT IS MOUNTED IN A DRY ENVIRONMENT, BUT NOT OVER A HEAT SOURCE OR IN DIRECT SUNLIGHT.    WEEE DIRECTIVE & PRODUCT DISPOSAL  At the end of its serviceable life, this product should not be treated as  household  or  general  waste.  It  should  be  handed  over  to  the applicable  collection  point  for  the  recycling  of  electrical  and electronic  equipment,  or  returned  to  Multitone  or  their  agent,  for disposal.  Company Liability  The information in this manual has been carefully compiled and checked for technical accuracy. Multitone Electronics plc accepts no liability for inaccuracies or errors. In line with the company policy of technical advancement, the information within this document may be changed. The user should ensure that the correct issue of the document is used. Comments or correspondence regarding this manual should be addressed to: Safety Summary Important Safety Information The Multitone i-Page IP133 Radio Paging Transcoder equipment, contains a low power (5 Watts) radio transmitter and is intended for use with either an externally mounted dipole antenna, or a “local” unity gain (or less) "desk-top" whip antenna. The equipment’s performance may be  characterized in  accordance  with the recommended MPE  requirements  of  the  European  Council  Directive  1999/519/EC  on  the  limitation  of exposure of the general public to electromagnetic fields (0Hz - 300GHz), as given in Annex III, Table 2; the requirements of FCC 47CFR and Industry Canada Standard RSS102. Where an installation is to be fitted with a "local" whip style antenna, the following criteria must  be  adhered  to,  in  order  to  reduce  and  comply  with  the  Electro-magnetic  radiation absorption regulations.  Multitone Electronics plc  Technical Publications Hansa Road Hardwick Industrial Estate Kings Lynn Norfolk PE30 4HX Englan
NOTE: Any equipment and antenna that is installed within an area normally populated whilst it is in use, must be located in a position where people may not approach, or be located within 1m of the radiating antenna, for periods in excess of 5 mins. in any 1 hour.  This  distance  is  calculated  to  include  an  additional  safety  margin  for  the product.  Compliance Information EU  Territories  -  This  product  complies  with  the  requirements  of  the  EU  Radio  & Telecommunications  Terminal  Equipment  Directive  99/5/EC.  A  complete  copy  of  the associated Declaration of Conformity for this and other Multitone products may be found at the Multitone Internet address www.multitone.com. This is Class 2 type equipment under the terms of the R & TTE Directive and is therefore subject to restrictions in its use. Before installation and use,  consult  your  local  radio  communications  spectrum  authority,  for licensing and frequency regulations.  US  &  Canada  -  This  product  has  been  tested  and  certified  for  use  in  both  the  US  and Canada. Any modifications to this  equipment not expressly authorised by Multitone,  could void the user's authority to operate the equipment. (The  term  "IC:"  before  the  certification/registration number,  only  signifies  that  the  Industry Canada technical specifications were met.)  Installation Notes       The equipment should be positioned so that there is no interference to the flow of air around the  unit  and  away  from  sources  of  heat.  It  should  only  be  mounted  to  a  wall,  as recommended in the installation instructions.  Care must be taken during installation to keep the power supply away from excessive RF fields.  Where the transmitter power is to be greater than 2.5W, the antenna must be sited a minimum of 1.5 metres away from the IP133 housing and power supply.  In cases where a close-coupled antenna must be used, the transmitter power must be reduced to a maximum of 2.5W and care must be taken to position the antenna at least 0.5m from the power supply unit.  All installation wiring should be carried out in accordance with recognised Codes of Wiring Practice,  applicable  to  the  equipment  and  circuits  involved,  e.g.  Mains  power,  telephone and/or radio. Power supply cords and other leads should be routed so that they are not likely to be walked on, or pinched by items placed upon or against them.   WARNING Do not install / use this equipment near sources of water, moisture, or in areas where explosive gases may be present! Do not expose to strong magnetic fields, extreme temperatures or strong sunlight.
Particular attention should be paid to cord entrance and exit points.  Where installation involves an external radio aerial/antenna, the antenna should be located away from  power lines. Ensure that where applicable the antenna system is grounded, to provide some protection against voltage surges and the build-up of static charges.  This equipment has been designed to conform to the relevant Radio and EMC performance standards,  but  it  may  be  necessary  to  take  additional  precautions  during  installation,  to ensure continued compliance. Use  only  cables  supplied,  or  suitably  rated  power  cables  and  screened  signaling  cable. Where quoted, do not exceed specified cable lengths and keep cable runs to a minimum, especially on the outside of buildings.  Do not unnecessarily route wiring alongside cables from or through areas that are a source of interference e.g. heavy plant and switch rooms, RF transmitter housings, without taking suitable precautions to reduce EM interference coupling. Where  necessary,  use  additional  protection  e.g.  armoured  trunking,  surge  arrestors, especially on the outside of buildings.  Where any interference problems are observed, it may be required to fit additional filtering components such as ferrite absorbers, or in-line filters. If such action proves to be necessary, contact either Multitone or their authorised agents.  Connection of Power Supplies Use only power sources specified, or supplied by Multitone. The use of another device will invalidate any declared conformity for this equipment, if as a result it ceases to conform to those standards on which conformity is based. The equipment should only be connected to a power supply as described in the operating instructions, as marked on the equipment, or supplied by Multitone. Do not overload outlets and extension cords, as this can result in fire, or electrical shock. Where equipment has been provided with a three-wire grounding type plug, this plug will only fit a grounding type power outlet. This is a safety feature and should not be defeated. If you are unable to use a grounding outlet, contact your electrician. Where equipment has been has been provided with a polarised line plug (one blade wider than the other - US/Canada), this plug will only fit a power outlet one way. This is a safety feature and should not be defeated. If you are unable to insert the plug fully, try reversing the plug. If the plug still does not fit, contact your electrician to replace the obsolete outlet.  Servicing This equipment contains non user-serviceable parts. All repairs to be undertaken by qualified service personnel. In the case of a problem, please contact your service representative/agent. All the safety and operating instructions should be read before the equipment is connected and operated and retained for future reference. All warnings marked on the equipment should be strictly adhered to. No attempt should be made to remove any designated safety covers, as these areas contain voltages of a sufficient magnitude to constitute a risk of electric shock to personnel.
Acknowledgement  i-Page wishes to acknowledge that the TCP/IP stack used in this product is Copyright (c) 2001, 2002 Swedish Institute of Computer Science. All rights reserved.  This file is part of the lwIP TCP/IP stack. Author: Adam Dunkels adam@sics.se.  THIS SOFTWARE IS PROVIDED BY THE AUTHOR ”AS IS'' AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
 1 i-Page Installation & User Guide                                                                      9261-8879 Iss 2 i-Page User & Installation Guide   Product Overview  Multitone i-Page is a small to medium business transcoder and supports a range of Multitone and OEM pagers. With a synthesised transmitter that can operate at up to 5watts, i-Page has good radio coverage in the majority of environments.  Multitone i-Page can also be integrated with other Multitone messaging products to provide messaging management from building and property management systems, fire alarms, security alarms and other safety, property or security devices.  Output of messaging alarms can also be directed to other mobile DECT, PMR, GSM, WiFi or personal security devices.  Contact Multitone for further information, or visit our website on www.multitonei-page.com.
 2 i-Page Installation & User Guide                                                                      9261-8879 Iss 2 1.0 Checking supplied equipment Unpack and examine the contents against the list given below:   i-Page Transcoder Unit Qty 1 (Fitted with wall mounting plates).   Power supply unit, 3-pin plug (UK), 2-pin (Europe) or 2 pin (US/Canada) Qty 1   Desk top antenna assembly * Qty 1 Part no 5501-0024 o  Supplied only when requested on SSF  o  Note that any alternative aerial must be an approved product supplied by Multitone   Set up and assembly guide 9261-8880   2 metre ethernet cable. Item 7718-0022   Your i-Page may have been supplied with either Multitone or OEM pagers   Your pagers are pre-programmed to work with Multitone i-Page on the same radio frequency, but will not have the pager addresses pre-programmed unless requested  1.1 Pager bundles   Pager bundles may consist of 4, 8 or 12 pagers, pre-programmed on to the radio frequency you have provided. o  Pagers will be pre-programmed onto the correct paging frequency o  The pager address required must be manually configured  1.2 Multitone pagers   A Multitone pager is pre-programmed and the pager address(RIC) may be viewed when the pager is turned on. The programmed frequency is noted on the back of the pager.  2.0 Tools The following tools may be required:-   Screwdrivers - flat and cross-point   2.5mm Allen key – for removing the wall mount plate   IDC Insertion Tool. Only required when DLC alarm contacts are equipped o  Installation of DLC alarm contact connections should only be carried out by a qualified service engineer   Drill and bits o  Required if i-Page is to be wall mounted  3.0 Equipment Required The following equipment may be required:-   PC or laptop, with cable part number 7761-8251 for adjustments to transmitter o  This work should only be carried out by trained personnel  o  Damage to transmitters due to incorrect procedures or hardware being used, will be charged at replacement costs   Multitone i-Page includes a browser and administration programme and is designed for use with any PC or laptop equipped with an internet browser programme such as Internet explorer, Firefox etc. connected to the customer network
 3 i-Page Installation & User Guide                                                                      9261-8879 Iss 2 4.0 Assembly requirements  4.1 Assembly The installation of alarms and servicing of this product must only be carried out by qualified personnel.   i-Page must be assembled with the following points in mind:-   Transcoder must not be installed next to the power supply or aerial – place these items as far away from the transcoder as possible, to ensure there is no interference   i-Page requires an IP network connection within 2 metres    A 120/230 volt mains socket must be within 3 metres of i-Page   Computer with a browser such as Internet Explorer, Firefox or other browser for programming i-Page    The IP133 i-Page can be wall or shelf mounted. i-Page is supplied for wall mounting and has wall  mount  plates  attached.  For  desktop  mounting  remove  the  wall  plates  and  fix  the enclosed rubber feet.  An earth wire MUST be fitted to the 4mm earth screw terminal on the back of the transmitter using the earthing lead supplied, or suitable equivalent.     4.2 Mounting         Attach the unit to the wall through the four mounting holes provided, using suitable fixings.  For desk or shelf mounting, remove the four screws using a 2.5mm Allen key and substitute the four rubber feet supplied. Where this method of installation is used, ensure that the unit is physically stable once all the leads have been connected.  Desk mounting The unit must be on a stable surface and the correct distance away from power supply, aerial or any other radio device.  4.3 Power supply The power supply can be wall mounted using an optional mounting bracket. This item is an accessory and may be purchased under part number 1061-8185-1.   The unit may be wall-mounted using the procedure below.   If i-Page is to be fitted on a wall use the mounting plates as a template and mark the drilling points, (note: plugs and  screws are not provided.).
 4 i-Page Installation & User Guide                                                                      9261-8879 Iss 2 Once the bracket is attached to the wall, fit the power supply to the bracket by feeding the DC output lead through the square hole in the bracket, from the inside. With the power supply sitting centrally between the two lugs of the bracket, insert the mains connector into the power supply through the oval hole, ensuring that it is fully pushed in.   This locks the power supply into the bracket.  Connect the power supply plug into the i-Page power socket.  4.4 Network cable Plug the network cable into a free network point and the other end into the RJ45 network cable connector.  4.5 Aerial fitting i-Page  is  supplied  with  a  desktop  aerial,  with  4  metres  of  cable  and  connector.  If  an alternative aerial is fitted, the impedance of the aerial should be 50 ohms.  Care must be taken during installation to keep the power supply away from excessive RF fields.  Where the transmitter power is to be greater than 2.5W, the antenna must be sited a minimum of 1.5 metres away from the i-Page housing and power supply.  In cases where a close-coupled antenna must be used, the transmitter power must be reduced to a maximum of 2.5W and care must be taken to position the antenna at least 0.5 metres from the power supply unit.  Any equipment and antenna that is installed within an area normally populated whilst it  is  in  use,  must  be  located  in  a  position  where  people  may  not  approach,  or  be located within 1 metre of the radiating antenna, for periods in excess of 5 mins in any 1  hour.  This  distance  is  calculated  to  include  an  additional  safety  margin  for  the product.  Note: You, (the user), are responsible for obtaining a license to operate your paging system from Ofcom (UK), or your local radio/spectrum licensing agency.  http://licensing.ofcom.org.uk/binaries/spectrum/business-radio/forms/OfW432.pdf   5. i-Page setup When i-Page has been assembled according to points 4.1 to 4.5 and the ethernet cable from i-Page is connected to a network point, you are ready to programme your system from your computer.  Note: Default IP address is 192.168.1.11 and network mask of 255.255.0.0    i-Page only supports a static / fixed IP address   A network address will need to be allocated by your MIS or IT manager
 5 i-Page Installation & User Guide                                                                      9261-8879 Iss 2   5.1 i-Page network setup   Changing computer IP address  o  (Example using Microsoft XP)   START - MY NETWORK PLACES – VIEW  NETWORK CONNECTIONS – LOCAL AREA CONNECTION   Select PROPERTIES  Select “Use the following IP address”. Enter, 192.168.1.11 and Netmask 255.255.0.0  Select “OK” and “OK” and the new IP address will be saved   Open your default browser and type; o http://192.168.1.11/ into the top bar o  You will see the main screen of Multitone i-Page  displayed and can commence programming     There is no default password     Login to i-Page and the menu option below will be displayed  The menu items presented on the left hand side of the screen are used to programme i-Page and to send messages to users and groups.  Logout   - Used to log out of Multitone i-Page Paging   - User and administration interface for programming and paging Users   - Add, amend or delete users DlC   - Programme DLC alarm details Groups   - Add and remove groups Messages   - Add or remove stored messages up to 80 characters Clock   - Set time and date Password   - Set one administrator or five user passwords Paging setup   - Set system address, paging format, time on/off, message length and                                 coverage test Language   - Select browser and pager languages IP settings   - Set static IP address, Netmask, gateway and Syslog for i-Page Serial port   - Select serial port protocol Backup/restore- Backup and restore i-Page data Factory reset      - Reset i-Page to factory setting. Note that all previous system data will be         erased!  5.2 Browser IP settings The majority of businesses have a network managed by an IT or MIS manager and they will be able to assist with the following instructions and will also need to provide an IP address for i-Page, unless the default IP address is used.  These settings allow any user or administrator to use i-Page from their internet browser software (Internet Explorer, Google, Firefox etc.).  Log in to i-Page, PASSWORD - no password required.
 6 i-Page Installation & User Guide                                                                      9261-8879 Iss 2 Select IP settings from the list. Your i-Page unit may require a new IP address in order that it may be accessed from your local network. Contact your IT / MIS network manager for details or assistance.  You must make these changes, in order for you to use you i-Page on your local network. (Refer to section 5.1.)  Enter the new IP address and Netmask plus gateway and Syslog IP address.  Example: Obtain the IP address Netmask, gateway and Syslog details from your IT network manager.   A gateway address is only required if i-Page will be accessed from a different LAN network e.g. any computer not on the main network. So any computer in this example with an IP address of 10.1.192.xxx, will not require a gateway address. Syslog is a standard for logging program messages. It allows separation of the software that generates messages from the system that stores them and the software that reports and analyses them. Leave on 0.0.0.0 if not used. It also provides devices which would otherwise be unable to communicate, a means to notify administrators of problems or performance.  There are a number of free Syslog programmes available on the internet.   SUBMIT the changes to i-Page. Your i-Page IP address has now changed   Change the IP address of your computer back to its previous static or DHCP address (Refer to section 5.1.)   Log on to i-Page using the programmed static IP address, You are now ready to complete programming of i-Page 5.3 Language settings i-Page supports seven languages which may be enabled for the browser and / or pager. All common browser programmes are supported. Languages supported include:-   English  German  French   Italian   Spanish  Danish   Norwegian  Note:- not all pagers will support the languages available on i-Page.  5.4 Clock setting Select the CLOCK menu and input time, month and day. SUBMIT to save. This is the time and date used by the pager. Not all pagers support the time of date clock function.  Setting the clock does not work with the OEM POCSAG pagers.   IP address for your network   Netmask for your network   Gateway address **   Syslog computer address ** ** Syslog and gateway are not      essential.
 7 i-Page Installation & User Guide                                                                      9261-8879 Iss 2 5.5 Paging setup The PAGING SETUP menu is used for setting basic message type details and an engineering test for transmitter range.  The PAGER ADDRESS is a 7-digit number consisting of a 3-digit SYSTEM ADDRESS and a 4-digit USER NUMBER.   The pager address is also known as a RIC or CAP CODE                     5.6 Passwords The web interface supports one administration password and one user password.   Only one administrator may be active at any one time and if a second administrator logs on then the first will be logged off.  Login only prompts for password, (not user ID); the Password used determines the access security level e.g. 2 very insecure passwords could be “paging” and “admin”.  Paging access can have an empty password, just hit submit, but an admin password must be set. Up to five operators at Paging level can be simultaneously logged in to i-Page using the same user password.  The web interface can be set to display in English, German, French, Spanish, Italian, Danish and Norwegian.  5.7 Adding users Your i-Page has been supplied with a number of pagers. Each pager must be programmed to operate on the same frequency as your paging system.  You may add up to 256 users to i-Page.  Depending on your order requirements your pagers may have been pre-configured with a pager address,(RIC/CAP CODE). The pager address, (RIC/CAP CODES) may be displayed on the pager at start-up, depending on the pager type.  The pager address is a 7-digit number consisting of a 3-digit SYSTEM ADDRESS and a - digit USER NUMBER. For example a pager address of 0011234, the user number would be 1234 and a pager address of 0010011, the  user number would be 0011. The pager user number is also known as a RIC code or CAP CODE.  A user number may be up to 4 digits long and is the four right-most numbers.     System address – These are the left-most 3 digits of the pager address Code format – Select one of the options provided. This must be the same as your pager type   Time of day – On or off   Message length – Default is120 characters   Coverage test – Is for service use and may be used to identify locations where pagers may not work. The test call is repeated to the designated user number until disabled
 8 i-Page Installation & User Guide                                                                      9261-8879 Iss 2    Select MESSAGES    Enter NEW   Enter message   SUBMIT to save the message Fewer than 4 digits will be packed with leading zeros. For example, if the user number entered is 1 then the saved user number will be 0001.        5.8 Adding groups   5.8 Adding groups You may create up to 40 groups of pagers, each with up to 96 members. The permitted number of characters for the user and group name is 50.     characters.          5.9 Stored messages A maximum of 32 stored messages of 120 characters may be configured.                            Add user number   Add name / description (maximum of 50 characters)   Submit to saveTo REMOVE a uyser, select “Remove”. There is no prompt to check the action is correct.    Select GROUPS   Enter 4-digit group number    Enter name / description for group   Select all pagers to be included within the group   Submit to save
 9 i-Page Installation & User Guide                                                                      9261-8879 Iss 2 5.10 Adding DLC alarm contacts i-Page provides 14 active closed alarm contacts. DLC’s are dry contacts and do not support any drivers for load current.  The remote device contact must provide a Lo (Ground) volts point, or a logic value not exceeding 3.3 volts on the alarm wire, to activate i-Page.  When a DLC is activated a message will then be sent to a user or group.  Refer to technical specification in Appendix 1 for DLC operational details and wiring.       Test the alarm contact operation  A DLC cable part number 7761-8831 may be  ordered as an accessory. This is a special cable.      5.11 Serial port The serial port is designed to receive serial data from an external source such as a building management or property management systems, serial alarms, fire alarms or other serial alarm data.  i-Page supports a number of common serial alarm data protocols.   In the event that the protocol is not supported contact Multitone for advice and support.            Connection of a serial data input requires a standard 2 metre null-modem cable.  Multitone part number 7718-0030 is available for this purpose.           Select DETAILS for DLC   Input message (maximum of 120 characters).   Select beep code 1 to 8   Select user or group   Submit to save     Select SERIAL PORT   Use drop down menu to select protocol o  TAP, TAP CR, ESPA, MEP, AUSTCO, MSP/Morley o  Baud rate o  Data bits o  Stop bits o  Flow control   Note that these settings must be the same as the external data source
 10 i-Page Installation & User Guide                                                                      9261-8879 Iss 2   5.12 Backup and restore The backup and restore options allow you to save system data and restore if and when required. Always backup your system data when first setting up i-Page or when any changes are made to the settings.    To backup system data;   DOWNLOAD o When the “file download” screen opens select SAVE o  Give the file a name / date and save to the i-Page folder   You will need to create this folder., this should be on the local network for safety   To restore backup system data o  BROWSE for the file to be restored and select Select UPLOAD. Do not interrupt the upload!  5.13 Factory reset Factory reset will clear all system data and restore all settings to default.                -Page will need to be reprogrammed, either by the re-entry of new data, or by restoring the most recent backup file. If you select the factory reset option, you will be presented with the following message:-  Factory Reset  Proceeding with this action will delete all devices from the database and return all settings to factory values.  Take a backup first if there is any possibility that the existing data is required. After the reset the i-Page unit will be available on 192.168.1.11.  Use Admin password after a factory reset and your computer will need to have the static IP address changed to 192.168.11.1 (see section 5.1).  6.0 Engineering button  The unit has an inset small blue button which has two different functions as follows:  A) Field software upgrades (see section 10.0)   B) Identification of the unit’s IP address   The Engineering button accessible from the front of i-Page toggles between normal operation and engineering mode when power to the unit is maintained To activate, do not remove power, press the button in and release the button after a few seconds.  i-Page may now be accessed from its default IP address of 192.168.1.11,allowing access when you don’t know the unit’s IP address. The Administration password is also temporarily set to ”Admin”.
 11 i-Page Installation & User Guide                                                                      9261-8879 Iss 2 Activating the button again will return the unit to its original IP address.  When activating the button, ensure that it is depressed squarely, and released fully.  7.0 Paging users and groups The PAGING interface allows you to:-    Send free format messages to a pager   Send free format messages to a group    Send preset messages to a user or group   Select a beep code for the message  Select PAGING from the menu.     Select one of the optional 8 beep codes    Select a user or group   Input your message or select a PRESET message  SEND the message  If no message is entered or selected, you will see a message “Error: No message entered – call not sent.”  7.1 Logout When administration or messaging has been completed select LOGOUT.  In the event that an administrator or user has not logged out, any other user logging in will override the person already logged in.  This ensures that access to the paging systems is always available.  8.0 SYSLOG message tracking If you require confirmation that the message has been sent, then you can use any one of the freeware Syslog software packages available on the internet.  The software must be installed on a computer, preferably one that has a static IP address.  Programme the IP address of the Syslog server in the IP SETTINGS menu.  9.0 Transmitter alignment The i-Page transmitter is factory set, according to the frequency requested when ordered. It may be necessary to re-align the transmitter in the event of any problems or to change the frequency.   This work must not be carried out by the user. Please contact your supplier or maintainer, for advice or support. Refer to Multitone document 9261-8252.
 12 i-Page Installation & User Guide                                                                      9261-8879 Iss 2  10.0 Software upgrades Upgrading software can only be carried out by your supplier or maintainer.  Programming software may be obtained from the support section of the Multitone website:-  http://www.Multitonei-Page.com.  Download the zip file and save to the computer from which programming will take place.  Run the program:-  "C:\Program Files\Texas Instruments\Stellaris\LM Flash Programmer\" and configure the following options:-      Quick set   - Manual configuration   Interface   - Serial UART   Check    - Disable baud rate   COM port   - The COM port to be used for programming   Baud rate   - 115200   Transfer size  - 60  Select the PROGRAM menu and check the box for “Reset MCU” after program. This ensures that i-Page will restart after the programme has been loaded.     Do not change any other menu options! Backup i-Page data before re-programming.
 13 i-Page Installation & User Guide                                                                      9261-8879 Iss 2  Field software update The software involves a boot loader which can accept new software.  Turn the power off, wait for 10 seconds whilst the green power lamp extinguishes, depress the button then repower the unit maintaining the button press for a few seconds. Release the button. The green power lamp will come on, but if the ethernet cable is connected, the ethernet LEDs will remain off. The serial port will now be available for input of a new i-Page software issue.   Use the LM programme software to upload a new image. Connect a null modem cable between i-Page and the computer, browse to the i-Page binary firmware file, select and press PROGRAM.  Do not interrupt whilst the programme is being loaded and has reset i-Page, as this may cause an irrecoverable error.  To resume normal operation after the upload, the ethernet LEDs must be flashing. If the ethernet is not in use, then it may be advisable to repower the unit.  Check that i-Page is operating correctly and that a paging message may be sent.
 14 i-Page Installation & User Guide                                                                      9261-8879 Iss 2 Appendix 1  DLC Alarm and Serial Port Technical Requirements                            DLC alarm contacts i-Page provides up to 14 alarm contacts. The cable is not supplied with i-Page and may be ordered separately under part number 7761-8831.  The cable must be terminated in accordance with this guide.   Any damage to i-Page or customer equipment resulting from connection to high voltages is not the responsibility of Multitone Electronics.   DLC’s are inputs only and intended for “dry” switch contacts, (no current), or simple logic signal ports. Ideally any logic signal inputs should not exceed 3.3V.  Serial port data input The following protocols are supported on i-Page:-  TAP MEP (Multitone protocol), ESPA 4.4.4, AUSTCO Nursecall protocol, and MSP / Morley fires protocol.  If any other protocols are used, contact Multitone for advice and support.  We can offer a field configurable protocol converter for the majority of applications, to convert any serial data stream into TAP or MEP protocols.  Use a standard serial Null modem cable with 9-way female connectors at each end; Multitone part number 7718-0030.
 15 i-Page Installation & User Guide                                                                      9261-8879 Iss 2 Appendix 2 – Frequently Asked Questions     I cannot log in to my i-Page:-  o  Have you set the static IP address on your computer?   No – Refer to section 5.1 of installation or starter guide o  Is the static address in the same range as i-Page 192.168.1.11?   To check go to START – MY NETWORK PLACES – VIEW NETWORK CONNECTIONS – Select Local area connection   Bottom left hand corner box DETAILS will show the IP address of your computerHow do I know what my IP address is for Windows XP?  o Start-connect to – show all connections o Click on “local area connection” and the details of the connection will be shown in a box at the  lower left of the screen      I have a new pager, but it does not work.   What type of pager is it?  o  If it is a Multitone pager, check the back of the pager for the frequency and compare with the i-Page menu. What frequency is it on? Multitone pagers - Check the back of the pager. o  Have you programmed the CAP CODE user details?   No. Use the programming guide, or go to the website and download the video file    For more information go to http://www.multitonei-Page.com
 16 i-Page Installation & User Guide                                                                      9261-8879 Iss 2 Appendix 3- i-Page Specifications   Transmitter performance - i-Page  * Frequency range: 438 to 470MHz  * Frequency stability: +/-2ppm  * Output power: 2.5W / 5W  * Duty cycle: ≤100%  * Normal load impedance: 50 ohms  * VSWR protection against short term removal of the antenna (maximum of5 calls    with antenna disconnected)  * Channel spacing factory set to: 10, 12.5, 20 or 25kHz.  * Antenna stand-alone base rear mounted loaded UHF whip, with 4metre cable UHF stub   Standard features  * Paging formats: Multitone Mk6, Mk7 and POCSAG (only one is selectable for use)  * Beep codes: 8 selectable beep codes  * Numeric messages: Up to 12 digits (Mk6)  * Alphanumeric messages: Up to 240 long text messages   * Speech transmission: Up to 256 seconds total transmission time  * Team call: Any format teams; 40 teams with up to 96 team members  * 14 DLC alarm contacts (unpowered circuits, max loop resistance 150 ohms)  * Up to 256 users (Pagers)  Protocols  Computer interface serial data, proprietary protocol, TAP, MEP, MSP, Morley, ESPA 4.4.4 and AUSTCO using RS232C. Full protocol details available upon request.   Power input  * Switch mode power supply. 110V to 240V and 1.5A   Physical  Dimensions: 105mm (w) x 175mm (d) x 65mm (h)  Weight: 700g  Environment  Operating temperature: -10°C to +55°C
 17 i-Page Installation & User Guide                                                                      9261-8879 Iss 2                 Appendix 4 – Multitone pagers                    Multitone can offer a range of pagers for use with i-Page  RPR580 paging receiver Mk7 Part no.  http://www.multitonei-Page.com UHF receiver UHF receiver RPR583MK4 Selectable 2-line or 4-line alphanumeric display .3 selectable display fonts . Icon driven operation . Up to 1,000 character message length . Multiple message memories store up   to 24,000  chtrs . 8 information service mailboxes . Selectable audible and/or vibrate alert . Free holster and lanyard . Runs on one AAA battery . Battery saver RPR750 paging receiver Part no.  http://www.multitonei-Page.com RPR750 Mk6  The RPR750 is supplied in a tough, dustproof and water-resistant case, protected to IP54. The specially designed grip-tight clip enables you to carry your pager safely. Safe (ATEX) versions are also available, allowing the RPR750 to operate in most hazardous and hostile environments. UHF Receiver Mk6 RPR753MK6 RPR750 Mk6 Intrinsically Safe UHF receiver Mk6 IS RPR753MK6IS RPR750 Mk7   UHF Receiver Mk7 RPR753MK7 RPR750MK7 Intrinsically Safe UHF Receiver Mk7 IS RPR753MK7IS RPR750 POCSAG  UHF Receiver POCSAG RPR753POC RPR750 POCSAG Intrinsically Safe UHF Receiver POCSAG IS RPR753POCIS TLA850 paging receiver  Part no.  http://www.multitonei-Page.com UHF POCSAG   TLA853Mk2  Waterproof pager Part no. http://www.multitonei-Page.com  TPW-WP Robust waterproof and dustproof.   POCSAG pager. IP67 rated.  8 RIC codes with 4 sub addresses.  Alarm contact on pager cradle. MIT870 series pagers  Part no.  http://www.multitonei-Page.com UHF POCSAG MIT873   MIT873IS Display LCD 6-line:150 (6 rows of 25 characters).           Display LCD 4-line: (normal): 100 (4 rows of 25 characters). Display LCD 4-line (bold): 64 (4 rows of 16 characters).       POCSAG pager Frequency  http://www.multitonei-Page.com See Multitone price list  •2-line, 2-line bold or 4-line alphanumeric display  •20 characters per line display (2-line: 40 characters, 4-line 80 characters) •8 CAP CODES •Synthesised frequency •50 message capacity •Priority tone override   UHF 448-452MHz, UHF 452-456MHz UHF 456-460MHz UHF 460-464MHz UHF 464-468MHz UHF 468-472MHz
 18 i-Page Installation & User Guide                                                                      9261-8879 Iss 2   Appendix 5 – i-Page Spares  Spares will be limited to complete field replaceable components.                           Main spares Transmitter board and endplate assembly  - 0402-0017 Encoder board assembly      - 0402-0018 i-Page IP133 housing       - 0761-8857 End plate          - 0761-8857
 19 i-Page Installation & User Guide                                                                      9261-8879 Iss 2                                                         Multitone Electronics plc, Multitone House, Shortwood Copse Lane, Basingstoke, England, RG23 7NL Telephone: +44 (0)1256 320292   Fax: +44 (0)1506 462643  Email: info@multitone.com  Web: www.multitone.com  This document is for guidance only. Products and services offered are subject to availability and may differ from those described or  illustrated in this document as a result of changes. Specifications are subject to change without notice. Multitone Electronics plc is  part of Kantone Holding Ltd, a member of the Champion Technology group of companies. Registered office: Multitone Electronics plc, Shortwood Copse Lane, Kempshott, Basingstoke, Hampshire, RG23 7NL. Registered in England No. 256314. 9261 – 8879 Iss. 1   Cert No. FM 20122

Navigation menu